Key features
Typical application
·Maximum output power factor is 1, \mathsf{V A}{=}\mathsf{W}
·Upto 94% leadingefficiency.
·Level3Built-in lithiumbattery,synchronization with UPS (Capacity, health, behavior, external balancing)
·Extended backup time with up to 4-6 optional EBMs,with automaticdetection
·Compact design: 2U UPS+ 1U EBM
·Rack/tower dual set-up with rotatableLCD panel
·USB, RS232 port, dry contacts, RPO & ROO connectors, optionalSNMP
·Built-in Ethernet port for cloud connection
·Certification: CE,UN38.3, IEC62019, UL1973(PACK).


Rear panel

Product specification
Modelname | 1K | 1.5K | 2K | 3K | |
Powerrating | VA/Watt | 1000VA/1000W | 1500VA/1500W | 2000VA/2000W | 3000VA/3000W |
Efficiency | Line mode | upto 91.3% | up to 92.1% | upto93.8% | up to 94% up to 98.4% |
ECOmode | up to 97.1% up to 98.2% | up to 97.8% | |||
Input performance | Voltagerange | 160-300V 100% load, 110-160V derating to 50% load linearly | |||
Rated frequency | 50Hz/60Hz | ||||
Frequencyrange | 40Hz-70Hz (45Hz-55Hz, 54Hz-66Hz @ load>60%) | ||||
PF THDI | >0.99 | ||||
Input connection | <5.5% | <5% | |||
Output performance | Socket(RT) | 1x IEC C14 | <5% 1x IEC C20 | ||
Rated voltage | 200/208/220/230/240VAC(derating 10% at 208V, derating 20% at 200V) | ||||
Rated frequency | 50Hz/60Hz | ||||
MaximumPF | PF = 1 | ||||
Voltageaccuracy | ±1% | ||||
THDV | <1% linear load; <4% nonlinear load | ||||
Transfertime | Oms@line <-> battery; 4ms @ line <>bypass; 10ms @ EC0 <->Inve rter | ||||
Crest Ratio | Max 3:1 100% | ||||
Overload Output connection | 125 | ||||
Socket | 1 main outlet group (with 4 x IEC C13) | 1 main outlet group (with 1 x IEC C19 + 4 x IEC C13) | |||
1 programmable outlet group (with 4 x IEC C13) | 1 programmable outlet group (with 4 x IEC C13) | ||||
Loadsegmentcontrol Short-circuit current | 1programmableloadsegmentcontrol | ||||
(RMS)/protect time | Bypassmode | 550A/2.8ms | 699A/7ms | 699A/7ms | |
Normal/Batterymode | 20A/100ms | 36A/100ms | 54A/100ms | ||
Voltage | 48VDC | 76.8VDC | 76.8VDC | ||
Battery | Capacity (AH) | 9Ah | 9Ah | 9Ah | |
Material | lithium iron phosphate (Li-FePO4) | ||||
MaximumEBMquantity | |||||
EBM auto detection | 4 | ||||
Battery Hot swappable | Yes Yes | ||||
Charging method | BMS | ||||
Charger | Charging current | 1.5A | 1.5A | ||
Recharging time | 1.5A | ||||
Othermode HMI | CVCF | 3.6h to 90% Yes (derating to 60% load) | 4.6h to 90% | 4.6h to 90% | |
Display | Dot matrix LCD (optional segment LCD) | ||||
Language | Multi-Language | ||||
USB | USB 2.0 with HID power device | ||||
RS232 | Yes (DB9) | ||||
Dry in/out | 1 programmable dry in; 1 programmable dry out | ||||
RPO | Yes | ||||
Intelligent slot | Yes(for long card) | ||||
Network card | OptionalNMClongcard | ||||
Modbus card | Optional, CMC LongCard | ||||
Dry contactor card | Optional, AS400 Long Card | ||||
Wirelessmodule | Optional | ||||
IOTEthernetport | RJ45 | ||||
Monitorsoftware Dimension(W*D*H)mm | Winpower,WinpowerViewAPP | 438*600*85.5(2U) | |||
Physical performance Environment Certification EMI EMS | IP protection level | 438*445*85.5(2U) | |||
Plug solid | IP20 CE/CB, IEC62040, UN38.3 IEC62619, UN38.3, UL1973 compliant | 0-40°℃ 0-95% <50dB at front 1m C2 IEC/EN 61000-4-2 IEC/EN 61000-4-3 IEC/EN 61000-4-4 IEC/EN 61000-4-5 | |||
Wheel Operating temperature storage temp Relative Humidity Operating Altitude Acoustic Noise UPS EBM Conduction/Radiation ESD RS EFT Surge |
InitialSpec.Due tocontinuous product improvement, pecifications aresubject tochange without notice.
PHOENIXTECTM
ADDRESS: No.129, Sec. 2, Datong Rd., Xizhi Dist.,
New Taipei City 221424, Taiwan (R.0.C.)
TEL: +886 2 6614 2000
FAX:+886 266142099