WT3300 卫生型压力变送器选型资料目录
1
目录
1 WT3300 卫生型压力变送器产品简介 ·······································································(2)
2 WT3310 压力、绝压变送器概述 ·············································································(3)
3 WT3320 液位变送器概述 ·····················································································(10)
4 WT3330 远传变送器概述 ·····················································································(16)
5 支架················································································································(25)
6 HHT375 手操器 ································································································(26)
7 HART MODEM ································································································(26)
订 货 须 知
1 产品的选型代码应根据选型表按需要确定,数字、符号须填写清楚、完整、准确无误。
2 变送器订货时须注明:型号、规格及选项等代码,标定范围(下限值、上限值)和单位,输
出形式(线性或平方根等),显示形式和单位(带 LCD 表头时)等。
3 如无特别说明,变送器按如下组态:测量范围为 0~最大量程上限(URL),线性输出,位号
无,表头显示为工程单位 kPa(带 LCD 表头时),输出电流限值及电气阻尼为默认值。
4 为使变送器性能最优,建议选择小量程比,不跨量程档选型。
5 本公司承诺免费修理或调换质保期内有质量问题的产品,质保期外产品的修理本公司将酌情
收取成本费。
6 购买、使用者应对变送器的选型、防腐、安装和使用负责。
(本选型资料若有变化,怒不另行通知,所供产品以购销合同为准)
WT3300 卫生型压力变送器产品简介
2
WT3300 卫生型压力变送器产品简介
上海威尔泰公司是国内知名的压力变送器生产制造商,采用微硅固态复合传感器技术及金属
电容式传感器技术,生产有自主研发的WT3300、WT3600、WT3000、WT2000智能压力变送器和
WT3000N核安全级压力变送器,组装生产有德国ABB公司MV2000T智能压力变送器。威尔泰变送
器包括差压变送器、压力变送器、绝对压力变送器和各式液位、远传差压/压力/绝对压力变送器,
最高测量基本误差为±0.05%,测量范围从微差压到高压力,输出符合HART、PROFIBUS-PA通信
协议,接液材质和灌充液丰富,产品抗干扰能力强,性能稳定,已投放市场三十多年近百万台套
的压力变送器广泛应用于我国的各种工业领域,并已进入欧洲、亚洲等地区。
WT3300卫生型压力变送器主要用于食品、饮料、医药等场合,对测量压力或液位的仪表结构
上、材质上、工艺上等有特殊要求。威尔泰建有一百多平方米的千级净化室用于一级传感器的封
装,三百多平方米的万级净化室用于二级传感器的制造,由一台步入式和九台立式高低温箱及其
控制系统组成了自动温度补偿生产线,拥有覆盖高、中、低测量范围的DHI、MENSOR、GE等公
司的高精度压力标准器、高静压差压标准器,配备有电子束、激光、储能、氩弧等各式焊接机器,
以及快速群脉冲、浪涌、静电试验等EMC测试设备,此外,用于压力变送器生产的充灌、泵压、
疲劳、老化、检漏、检测的各式设备、工装一应俱全,所有这些设备以及成熟的生产工艺保证了
威尔泰压力变送器具有与国际同类产品相同的品质。
WT3300卫生型压力变送器的研发和生产,是为了确保食品、饮料、医药等行业的卫生和安全,
确保其不会通过接触的压力变送器与有毒、有害、有污染的物质成分接触和相混, 与食品药品直
接接触的压力变送器的材料选用、特殊结构、主要性能、生产工艺、表面处理等方面都有着一系
列的卫生要求。
WT3300卫生型压力变送器主要特点
⚫ 自主研发传感器及数字化电子部件,具有完全自主知识产权
⚫ 采用先进的微硅固态复合传感器技术
⚫ 高稳定性、高可靠性、高抗干扰性
⚫ 多种调试方法:表头按键、手操器、通信软件
⚫ 表头按键与 LCD 表头可实现变送器的功能组态
⚫ 全不锈钢一体化结构设计
⚫ 应用于食品、饮料、药品等领域
⚫ 测量介质:液体、蒸汽和气体
⚫ 基本误差:±0.075%,0.2%
⚫ 最大量程比:100︰1
⚫ 防爆标志:Ex ia ⅡC T4 Ga
⚫ 输出通信协议:HART
⚫ 输出功能:线性、平方根
⚫ 电磁兼容性:符合 EN 61326-1︰2006
⚫ 快速的动态响应
⚫ 防护等级:IP65
⚫ 灌充液:通过 FDA 认证的卫生型填充液
⚫ 隔离膜片:316L、哈氏合金 C
⚫ LCD 表头(可设定为背光)显示工程单位、百分数、电流值等
⚫ 过程接口:夹持式、耦合式
WT3310 压力、绝压变送器概述
3
WT3310 压力、绝压变送器概述
1 应用
WT3310 压力变送器广泛应用于食品、医药等行业压力、液位的测量,具有符合 4mA~20mA/HART 输
出信号,数字信号中包含有各种组态、信号状态及故障自诊断信息,LCD 表头用于显示过程压力、信号
状态及故障自诊断信息,表头按键可完成调节零满等多种组态功能。
2 工作原理与结构
WT3310 压力、绝压变送器使用先进的微硅固态复合传感器,采用模块化设计,由带集成电子适配
单元的传感器模块和带按钮控制单元的放大器组成。
压力、绝压传感器模块采用硅压力、绝压传感芯片,被测压力、绝对压力经隔离膜片及灌充液传
递至硅压力、绝压传感芯片上,四个制在传感芯片上的压阻效应的电阻随被测压力、绝对压力的变化
而变化,进而导致相应桥路输出电压的变化。与压力、绝对压力成正比的该输出电压由适配单元和放
大器转换为标准输出信号。
3 正常工作环境条件
(1) 环境温度:-40℃~+85℃,带LCD表头时为-20℃~+60℃。
(2) 最高允许介质温度:基本型100℃,高温型140℃。
(3) 相对湿度:0%~100%。
(4) 大气压力:86kPa~106kPa。
(5) 现场周围应不含有对铝、铬、镍、锌、不锈钢等具有腐蚀作用的气体及易燃易爆物质。
(6) 交流外磁场不大于400A/m。
WT3310 压力、绝压变送器概述
4
4 输入
零点迁移量
压力变送器:
最大正迁移量为测量范围上限值与测量量程之差。
最大负迁移量不大于大气压。
绝压变送器:
最大正迁移量为测量范围上限值与测量量程之差。
无负迁移。
测量范围
压力变送器
测量下限:-100%URL(≥-0.1MPa)~+100%URL-Span
测量上限:-100%URL+Span(≥-0.1MPa+Span)~+100%URL
远传绝压变送器
测量下限:0%URL~+100%URL-Span
测量上限:Span~+100%URL
量程、量程比、额定压力
WT3310 压力变送器量程、量程比、额定压力对照表
量程代码 最小量程 最大量程 最大量程比 压力极限
C 2kPa 40kPa 20:1 1MPa
D 2.5kPa 250kPa 100:1 1MPa
E 10 kPa 1MPa 100:1 3MPa
F 30kPa 3MPa 100:1 3MPa
L 10kPa abs. 40kPa abs. 4:1 1MPa
M 10kPa abs. 250kPa abs. 25:1 1MPa
O 30kPa abs. 3MPa abs. 100:1 3MPa
5 输出信号
4-20mA/HART 线性
普通型供电电源
HART 变送器:
变送器供电电源(指变送器电源端子处)为 11VDC~45VDC,带 LCD 显示表头时供电电源为 15VDC~45VDC,
纹波含量小于 0.1%,现场运行时,由配电器或稳压电源供电,一般工作电压为 24VDC。
防爆型供电电源
一般系统中可由配电器或稳压电源供电,本质安全防爆型变送器在本安系统工作时,应由安全栅供电并
传输信号。防爆型变送器供电电压为 24VDC。
负载特性
HART 变送器负载特性为:
RL≤(Vs-Vm)V/0.023A
WT3310 压力、绝压变送器概述
5
式中:RL---最大负载电阻;Vs---供电电源;Vm---无 LCD 显示表头时为 11V,带 LCD 显示表头时为 15V。
HART 通信时负载电阻(含信号接收电阻及信号传输导线电阻)要求 230Ω~600Ω。
量程和零位的调整
表头按键、HHT375 手操器(仅 HART 变送器)、支持 HAR 协议的通信软件。
响应时间
阶跃响应时间(63%)与量程和量程比有关,为 0.1s~1.6s(电气阻尼关闭时)。
电气阻尼:0.1s~60s。
故障报警
HART 变送器:
自诊断程序检测出故障,模拟输出高报电流或低报电流报警,其中:
(1) 高报电流:20.1mA~22.5mA可调,初始设置为:21.0mA;
(1) 低报电流:3.5mA~3.9mA可调,初始设置为:3.6mA;
(2) 高饱和电流:20.0mA~22.4mA可调,初始设置为:20.5mA;
(3) 低饱和电流:3.6mA~4.0mA可调,初始设置为:3.8mA。
必须满足的条件是:
(4) (高报电流 - 高饱和电流)>0.1mA;
(5) (低饱和电流 - 低报电流)>0.1mA。
6 不精确度
参比条件
(1) 温度:15℃~25℃(环境温度的允许最大变化速率为 1℃/10min,但不得超过 3℃/h);
(2) 相对湿度:45%~75%;
(3) 大气压力:86kPa~106kPa;
(4) 电源为 24VDC±1%,纹波含量小于 0.1%;
(5) 负载电阻为 250Ω±0.005%;
(6) 变送器:符合HART 协议、316L 隔离膜片、硅油灌充液、无零点迁移、无LCD 显示表头、线性输出、最大
量程。
除非另有说明,一般测定一个影响量对输出的变化时,其它影响量应保持在参比条件内。
不精确度:±0.075%URL。
注 1:包括端基不一致性、回差和不重复性误差。
注 2:当量程比大于 10:1 时,不精确度应附加上述不精确度指标值*(量程比值-10)/10。
长期漂移:±0.10%URL/3 年。
环境温度影响±0.075%URL/10℃ ;
电源电压影响:<±0.005%/V。
安装位置影响:零位偏差不超过 350Pa。建议在安装后投运前调零,其影响可修正掉。
7 防爆性能
WT3300 智能压力变送器已通过国家级仪器仪表防爆安全监督检验站(NEPSI)的检验、审查。
本安型
防爆安全性能符合 GB3836.1-2021“爆炸性气体环境用电气设备 第 1 部分:通用要求”及 GB3836.4-2021
“爆炸性气体环境用电气设备 第 4 部分 本质安全型‘i’”,产品防爆标志为 Ex ia ⅡC T4 Ga。
经 NEPSI 审查确认,WT3300 智能压力变送器可配用下列安全栅:德国 PEPPERL+FUCHS 公司:Z787、
WT3310 压力、绝压变送器概述
6
KFD2-STC3-EX1;英国 MTL 公司:MTL5042。
用户必须按要求选购相应的安全栅。安全栅必须置于非危险场所,其安装使用必须遵守该安全栅的使用
说明书。
8 材料
测量膜盒:316 不锈钢。
隔离膜片:316L 不锈钢、哈氏合金 C。
过程法兰/过程接头:316 不锈钢。
电子外壳:不锈钢。
灌充液:卫生型硅油。
接液 O 型圈
氟橡胶(FKM)、聚四氟乙烯(PTFE)、低温氟橡胶(FKM-GFLT)。
9 接口和界面
过程连接
夹持式、耦合式。
电气连接
不锈钢外壳,四芯M12×1航空插头。
可选航空母插头自带 2 米电缆。
表头按键
有三个按钮:M 按钮、S 按钮、Z 按钮。带 LCD 显示表头时,可实现(过程变量)查看、加压零位
迁移、加压满位设定、不加压零位设定、不加压满位设定、差压值的零点调整、测量范围平行迁移、
输出显示下限设定、输出显示上限设定、阻尼设定、报警电流选择、显示类型选择、单位选择、选择
输出特性、设定现场总线地址、软件版本(查看)等组态功能。
LCD 显示表头
2行、每行7个字符(含符号位及小数点),外加棒图显示。显示百分数、mA输出电流、带物理单位
的压力值、诊断信息及报警信息等。
输出通信
通信协议:HART。
硬件:支持HART的MODEM/耦合器/适配器及电脑。
软件:Precali(HART)或其它支持HART的软件。
手操器:HHT375(HART)。
10 其它
安装说明
变送器采用现场安装结构,具有防潮、防尘密封功能,将仪表直接安装到管道或容器上。最好使
过程接口轴处于垂直位置,以减小可去除的零点偏移,具体安装指南可参照使用说明书。
电磁兼容性(EMC)
符合 EN 61326-1:2006 标准,测试项目包括辐射骚扰(外壳)、传导骚扰(电源)、静电放电(ESD)
抗扰度、射频电磁场辐射抗扰度、工频磁场抗扰度、电快速瞬变脉冲群抗扰度、浪涌(冲击)抗扰度
和射频场感应的传导骚扰抗扰度。
抗机械振动和冲击
WT3310 压力、绝压变送器概述
7
振动频率:10Hz~60Hz,60Hz~500Hz。
振动峰振幅:0.14mm。
振动峰加速度:2g。
冲击峰加速度:10g。
防护等级:IP65。
绝缘电阻:>100MΩ(500VDC)。
密封性
变送器的测量部分在承受额定工作压力时保持密封状态,没有泄漏。
贮存温度/运输温度:-50℃~+85℃。
重量:约 0.8kg(不包括附件)。
WT3310 压力、绝压变送器概述
8
11 外形尺寸
D
44
50
56
68
2\"
D
64
WT3310 压力、绝压变送器概述
9
12 WT3310 压力变送器选型表
产品描述 必选项选型代码
选型
举例
WT3310 压力变送器 WT3310- WT3310-
输出信号
4mA~20mA/HART H H
测量范围(未迁移时)
0~40kPa
0~250kPa
0~1000kPa
0~3000kPa
0~40kPa abs.
0~250kPaabs.
0~3000kPa abs.
C
D
E
F
L
M
O
F
隔离膜片
316L 不锈钢
哈氏合金 C
灌充液
卫生填充液 USP 9
卫生填充液 USP 9
E
4
E
连接类型
基本型
高温型
J
S S
过程连接
ISO 2852 1〞
最大量程 3.0MPa
ISO 2852 1-1/2〞最大量程 2.5MPa
ISO 2852 2〞最大量程 2.0MPa
DIN 11851 DN25 最大量程 3.0Mpa
DIN 11851 DN32 最大量程 2.5Mpa
DIN 11851 DN40 最大量程 2.5MPa
DIN 11851 DN50 最大量程 2.0MPa
A
B
C
D
E
F
G
B
电气连接(防护等级 IP67)
不锈钢外壳,四芯 M12×1 航空插头,垂直安装
不锈钢外壳,四芯 M12×1 航空插头,水平安装
E
F
E
电气连接附件
航空母插头自带 2 米电缆
航空母插头不带电缆
G
H
G
特殊功能
LCD 显示表头(标配)
带背光 LCD 显示表头
3
4
3
铭牌和说明书
中文
英文
Z
Y
Z
产品认证(可多选)
本安型 Ex ia IIC T4 Ga
3-A 认证
B
A
B
A
WT3320 液位变送器概述
10
WT3320 液位变送器概述
1 应用
WT3320 液位变送器广泛应用于食品、医药等行业压力、液位的测量,具有符合 4mA~20mA/HART 输
出信号,数字信号中包含有各种组态、信号状态及故障自诊断信息, LCD 表头用于显示过程压力、信
号状态及故障自诊断信息,表头按键可完成调节零满等多种组态功能。
2 工作原理与结构
WT3320 液位变送器使用先进的微硅固态复合传感器,采用模块化设计,由带集成电子适配单元的
传感器模块和带按钮控制单元的放大器组成。
液位传感器模块采用硅差压传感芯片,被测压力、液位经隔离膜片及灌充液传递至硅差压传感芯
片上,四个制在传感芯片上的压阻效应的电阻随被测压力、液位的变化而变化,进而导致相应桥路输
出电压的变化。与压力、液位成正比的该输出电压由适配单元和放大器转换为标准输出信号。
应用场合与 WT3310 压力变送器基本相同,主要特别:该液位变送器可应用于有凝露和冷凝场合。
3 正常工作环境条件
(1)环境温度:-40℃~+85℃,带LCD表头时为-20℃~+60℃。
(2)介质最高允许温度: 140℃。
(3)相对湿度:0%~100%。
(4)大气压力:86kPa~106kPa。
(5)现场周围应不含有对铝、铬、镍、锌、不锈钢等具有腐蚀作用的气体及易燃易爆物质。
(6)交流外磁场不大于400A/m。
WT3320 液位变送器概述
11
4 输入
零点迁移量
最大正迁移量:+100%URL-Span
最大负迁移量:-100%URL(≥-0.1MPa)
测量范围
测量下限:-100%URL(≥-0.1MPa)~+100%URL-Span
测量上限:-100%URL+Span(≥-0.1MPa+Span)~+100%URL
量程、量程比、额定压力
WT3320 液位变送器量程、量程比、额定压力对照表
量程代码 最小量程 最大量程 最大量程比 额定压力
C 4kPa 40kPa 10:1 2MPa
D 5kPa 250kPa 50:1 2MPa
E 10kPa 1MPa 100:1 2MPa
5 输出信号
4-20mA/HART 线性
普通型供电电源
HART 变送器:
变送器供电电源(指变送器电源端子处)为 11VDC~45VDC,带 LCD 显示表头时供电电源为 15VDC~45VDC,
纹波含量小于 0.1%,现场运行时,由配电器或稳压电源供电,一般工作电压为 24VDC。
防爆型供电电源
一般系统中可由配电器或稳压电源供电,本质安全防爆型变送器在本安系统工作时,应由安全栅供电并
传输信号。防爆型变送器供电电压为 24VDC。
负载特性
HART 变送器负载特性为:
RL≤(Vs-Vm)V/0.023A
式中:RL---最大负载电阻;Vs---供电电源;Vm---无 LCD 显示表头时为 11V,带 LCD 显示表头时
为 15V。HART 通信时负载电阻(含信号接收电阻及信号传输导线电阻)要求 230Ω~600Ω。
量程和零位的调整
表头按键、HHT375 手操器(仅 HART 变送器)、支持 HAR 协议的通信软件。
响应时间
阶跃响应时间(63%)与量程和量程比有关,为 0.1s~1.6s(电气阻尼关闭时)。
电气阻尼:0.1s~60s。
故障报警
HART 变送器:
自诊断程序检测出故障,模拟输出高报电流或低报电流报警,其中:
(1)高报电流:20.1mA~22.5mA可调,初始设置为:21.0mA;
(2)低报电流:3.5mA~3.9mA可调,初始设置为:3.6mA;
(3)高饱和电流:20.0mA~22.4mA可调,初始设置为:20.5mA;
(5)低饱和电流:3.6mA~4.0mA可调,初始设置为:3.8mA。
必须满足的条件是:
(1)(高报电流 - 高饱和电流)>0.1mA;
(2)(低饱和电流 - 低报电流)>0.1mA。
WT3320 液位变送器概述
12
6 不精确度
参比条件:
(1)温度:15℃~25℃(环境温度的允许最大变化速率为 1℃/10min,但不得超过 3℃/h);
(2)相对湿度:45%~75%;
(3)大气压力:86kPa~106kPa;
(4)电源为 24VDC±1%,纹波含量小于 0.1%;
(5)负载电阻为 250Ω±0.005%;
(6)变送器:符合 HART 协议、316L 隔离膜片、硅油灌充液、无零点迁移、无 LCD 显示表头、线性输出、最大
量程。
除非另有说明,一般测定一个影响量对输出的变化时,其它影响量应保持在参比条件内。
不精确度:±0.2%URL。
注 1:包括端基不一致性、回差和不重复性误差。
注 2:当量程比大于 10:1 时,不精确度应附加上述不精确度指标值*(量程比值-10)/10。
长期漂移:±0.50%URL/3 年。
环境温度影响:±0.2%URL/10℃ ;
电源电压影响:<±0.005%/V。
安装位置影响:零位偏差不超过 350Pa。建议在安装后投运前调零,其影响可修正掉。
7 防爆性能
WT3300 智能压力变送器已通过国家级仪器仪表防爆安全监督检验站(NEPSI)的检验、审查。
本安型
防爆安全性能符合 GB3836.1-2021“爆炸性气体环境用电气设备 第 1 部分:通用要求”及 GB3836.4-2021
“爆炸性气体环境用电气设备 第 4 部分 本质安全型‘i’”,产品防爆标志为 Ex ia ⅡC T4 Ga。
经 NEPSI 审查确认,WT3300 智能压力变送器可配用下列安全栅:德国 PEPPERL+FUCHS 公司:Z787、
KFD2-STC3-EX1;英国 MTL 公司:MTL5042。
用户必须按要求选购相应的安全栅。安全栅必须置于非危险场所,其安装使用必须遵守该安全栅的使用
说明书。
8 材料
测量膜盒:316 不锈钢。
隔离膜片:316L 不锈钢、哈氏合金 C。
过程法兰/过程接头:316 不锈钢。
电子外壳:不锈钢。
灌充液:卫生型硅油。
接液 O 型圈
氟橡胶(FKM)、聚四氟乙烯(PTFE)、低温氟橡胶(FKM-GFLT)。
9 接口和界面
过程连接
夹持式、耦合式。
WT3320 液位变送器概述
13
电气连接
不锈钢外壳,四芯M12×1航空插头。
可选航空母插头自带 2 米电缆。
表头按键
有三个按钮:M 按钮、S 按钮、Z 按钮。带 LCD 显示表头时,可实现(过程变量)查看、加压零位
迁移、加压满位设定、不加压零位设定、不加压满位设定、差压值的零点调整、测量范围平行迁移、
输出显示下限设定、输出显示上限设定、阻尼设定、报警电流选择、显示类型选择、单位选择、选择
输出特性、设定现场总线地址、软件版本(查看)等组态功能。
LCD 显示表头
2 行、每行 7 个字符(含符号位及小数点),外加棒图显示。显示百分数、mA 输出电流、带物理单位的
压力值、诊断信息及报警信息等。
输出通信
通信协议:HART。
硬件:支持 HART MODEM/耦合器/适配器及电脑。
软件:Precali(HART)或其它支持 HART 的软件。
手操器:HHT375(HART)。
10 其它
安装说明
变送器采用现场安装结构,具有防潮、防尘密封功能,将仪表直接安装到管道或容器上。最好使
过程接口轴处于垂直位置,以减小可去除的零点偏移,具体安装指南可参照使用说明书。
电磁兼容性(EMC)
符合 EN 61326-1:2006 标准,测试项目包括辐射骚扰(外壳)、传导骚扰(电源)、静电放电(ESD)抗扰
度、射频电磁场辐射抗扰度、工频磁场抗扰度、电快速瞬变脉冲群抗扰度、浪涌(冲击)抗扰度和射频场感
应的传导骚扰抗扰度。
抗机械振动和冲击
振动频率:10Hz~60Hz,60Hz~500Hz。
振动峰振幅:0.14mm。
振动峰加速度:2g。
冲击峰加速度:10g。
防护等级:IP65。
绝缘电阻:>100MΩ(500VDC)(防雷除外)。
防雷保护(耐瞬变电压):6kV(1.2×50us),3000A,100 次冲击;6kV(8×20us),3000A,200 次冲击;
4kV(10×700us),260A,1000 次冲击。
密封性
变送器的测量部分在承受额定工作压力时保持密封状态,没有泄漏。
贮存温度/运输温度:-50℃~+85℃。
重量:约 1.8kg(不包括附件)。
WT3320 液位变送器概述
14
11 结构尺寸
Z S M
Z S M
\"
WT3320 液位变送器概述
15
WT3320 液位变送器选型表(选项)
注:① 选型举例:WT3320-H/D/E/C/E/G/3/Z/B/A。
② 为使变送器性能最优,应根据测量范围选择相应量程,不跨量程档选型。
③ 如某项代码为有特殊要求的非标项,则该位代码可用 X 或 Y 表示,并给出 X 或 Y 的说明。
产品描述 必选项选型代码
选型
举例
WT3320 液位压力变送器 WT3320- WT3320-
输出信号
4mA~20mA/HART H H
测量范围(未迁移时)
0~40kPa
0~250kPa
0~1000kPa
C
D
E
D
传感器隔离膜片
316L 不锈钢
哈氏合金 C
传感器灌充液
卫生填充液 USP 9
卫生填充液 USP 9
E
4
E
过程连接
ISO 2852 2〞
DIN 11851 DN50
C
F
C
电气连接
不锈钢外壳,四芯 M12×1 航空插头,垂直安装
不锈钢外壳,四芯 M12×1 航空插头,水平安装
E
F
E
电气连接附件
航空母插头自带 2 米电缆
航空母插头不带电缆
G
H
G
特殊功能
LCD 显示表头(标配)
带背光 LCD 显示表头
3
4
3
铭牌和说明书
中文
英文
Z
Y
Z
产品认证(可多选)
本安型 Ex ia IIC T4 Ga
3-A 认证
B
A
B
A
WT3330 远传变送器概述
16
WT3330 远传变送器概述
1 应用
WT3330 远传变送器广泛应用于食品、医药等行业压力、液位的测量,具有符合 4mA~20mA/HART 输出信号,
数字信号中包含有各种组态、信号状态及故障自诊断信息, LCD 表头用于显示过程压力、信号状态及故障自
诊断信息,表头按键可完成调节零满等多种组态功能。
2 工作原理与结构
WT3330 远传变送器使用先进的微硅固态复合传感器,采用模块化设计,由带集成电子适配单元的传感器
模块和带按钮控制单元的放大器组成。
远传传感器模块采用硅差压传感芯片,被测压力、液位经隔离膜片及灌充液传递至硅差压传感芯片,四
个制在传感芯片上的压阻效应的电阻随被测压力、液位的变化而变化,进而导致相应桥路输出电压的变化。
与压力、液位成正比的该输出电压由适配单元和放大器转换为标准输出信号。
应用场合:介质温度超过常规表所能承受的最高温度,敞口灌适合用单远传变送器,密封罐适合用双法
兰变送器。
3 正常工作环境条件
(1)环境温度:-40℃~+85℃,带 LCD 表头时为-20℃~+60℃。
(2)介质最高允许温度: 250℃。
(3)相对湿度:0%~100%。
(4)大气压力:86kPa~106kPa。
(5)现场周围应不含有对铝、铬、镍、锌、不锈钢等具有腐蚀作用的气体及易燃易爆物质。
(6)交流外磁场不大于 400A/m。
4 输入
零点迁移量
WT3330 远传变送器概述
17
最大正迁移量:+100%URL-Span
最大负迁移量:-100%URL(≥-0.1MPa)
测量范围
测量下限:-100%URL(≥-0.1MPa)~+100%URL-Span
测量上限:-100%URL+Span(≥-0.1MPa+Span)~+100%URL
量程、量程比、额定压力
WT3320 液位变送器量程、量程比、额定压力对照表
量程代码 最小量程 最大量程 最大量程比 额定压力
C 4kPa 40kPa 10:1 2MPa
D 5kPa 250kPa 50:1 2MPa
E 10kPa 1MPa 100:1 2MPa
5 输出信号
4-20mA/HART 线性 、平方根
普通型供电电源
HART 变送器:
变送器供电电源(指变送器电源端子处)为 11VDC~45VDC,带 LCD 显示表头时供电电源为 15VDC~45VDC,
纹波含量小于 0.1%,现场运行时,由配电器或稳压电源供电,一般工作电压为 24VDC。
防爆型供电电源
一般系统中可由配电器或稳压电源供电,本质安全防爆型变送器在本安系统工作时,应由安全栅供电并
传输信号。防爆型变送器供电电压为 24VDC。
负载特性
HART 变送器负载特性为:
RL≤(Vs-Vm)V/0.023A
式中:RL---最大负载电阻;Vs---供电电源;Vm---无 LCD 显示表头时为 11V,带 LCD 显示表头时为 15V。
HART 通信时负载电阻(含信号接收电阻及信号传输导线电阻)要求 230Ω~600Ω。
量程和零位的调整
表头按键、HHT375 手操器(仅 HART 变送器)、支持 HAR 协议的通信软件。
响应时间
阶跃响应时间(63%)与量程和量程比有关,为 0.1s~1.6s(电气阻尼关闭时)。
电气阻尼:0.1s~60s。
故障报警
HART 变送器:
自诊断程序检测出故障,模拟输出高报电流或低报电流报警,其中:
(1)高报电流:20.1mA~22.5mA 可调,初始设置为:21.0mA;
(2)低报电流:3.5mA~3.9mA 可调,初始设置为:3.6mA;
(3)高饱和电流:20.0mA~22.4mA 可调,初始设置为:20.5mA;
(5)低饱和电流:3.6mA~4.0mA 可调,初始设置为:3.8mA。
必须满足的条件是:
(1)(高报电流 - 高饱和电流)>0.1mA;
(2)(低饱和电流 - 低报电流)>0.1mA。
WT3330 远传变送器概述
18
6 不精确度
参比条件
(1)温度:15℃~25℃(环境温度的允许最大变化速率为 1℃/10min,但不得超过 3℃/h);
(2)相对湿度:45%~75%;
(3)大气压力:86kPa~106kPa;
(4)电源为 24VDC±1%,纹波含量小于 0.1%;
(5)负载电阻为 250Ω±0.005%;
(6)变送器:符合 HART 协议、316L 隔离膜片、硅油灌充液、无零点迁移、无 LCD 显示表头、线性输出、
最大量程。
除非另有说明,一般测定一个影响量对输出的变化时,其它影响量应保持在参比条件内。
不精确度:±0.2%URL。
注 1:包括端基不一致性、回差和不重复性误差。
注 2:当量程比大于 10:1 时,不精确度应附加上述不精确度指标值*(量程比值-10)/10。
长期漂移:±0.50%URL/3 年。
环境温度影响
±0.2%URL/10℃ ;
电源电压影响:<±0.005%/V。
安装位置影响:零位偏差不超过 350Pa。建议在安装后投运前调零,其影响可修正掉。
7 防爆性能
WT3300 智能压力变送器已通过国家级仪器仪表防爆安全监督检验站(NEPSI)的检验、审查。
本安型
防爆安全性能符合 GB3836.1-2021“爆炸性气体环境用电气设备 第 1 部分:通用要求”及 GB3836.4-2021
“爆炸性气体环境用电气设备 第 4 部分 本质安全型‘i’”,产品防爆标志为 Ex ia ⅡC T4 Ga。
经 NEPSI 审查确认,WT3300 智能压力变送器可配用下列安全栅:德国 PEPPERL+FUCHS 公司:Z787、
KFD2-STC3-EX1;英国 MTL 公司:MTL5042。
用户必须按要求选购相应的安全栅。安全栅必须置于非危险场所,其安装使用必须遵守该安全栅的使用
说明书。
8 材料
测量膜盒:316 不锈钢。
隔离膜片:316L 不锈钢、哈氏合金 C。
过程法兰/过程接头:316 不锈钢。
电子外壳:不锈钢。
灌充液:卫生型硅油。
接液 O 型圈
氟橡胶(FKM)、聚四氟乙烯(PTFE)、低温氟橡胶(FKM-GFLT)。
9 接口和界面
过程连接
夹持式、耦合式。
WT3330 远传变送器概述
19
电气连接
不锈钢外壳,四芯 M12×1 航空插头。
可选航空母插头自带 2 米电缆。
表头按键
有三个按钮:M 按钮、S 按钮、Z 按钮。带 LCD 显示表头时,可实现(过程变量)查看、加压零位
迁移、加压满位设定、不加压零位设定、不加压满位设定、差压值的零点调整、测量范围平行迁移、
输出显示下限设定、输出显示上限设定、阻尼设定、报警电流选择、显示类型选择、单位选择、选择
输出特性、设定现场总线地址、软件版本(查看)等组态功能。
LCD 显示表头
2 行、每行 7 个字符(含符号位及小数点),外加棒图显示。显示百分数、mA 输出电流、带物理单位的
压力值、诊断信息及报警信息等。
输出通信
通信协议:HART。
硬件:支持 HART 的 MODEM/耦合器/适配器及电脑。
软件:Precali(HART)或其它支持 HART 的软件。
手操器:HHT375(HART)。
10 其它
安装说明
变送器采用现场安装结构,具有防潮、防尘密封功能,通过安装支架进行管装或墙装,固定变送器于任
何位置。最好使过程法兰轴处于垂直位置,以减小可去除的零点偏移。
电磁兼容性(EMC)
符合 EN 61326-1:2006 标准,测试项目包括辐射骚扰(外壳)、传导骚扰(电源)、静电放电(ESD)抗扰
度、射频电磁场辐射抗扰度、工频磁场抗扰度、电快速瞬变脉冲群抗扰度、浪涌(冲击)抗扰度和射频场感
应的传导骚扰抗扰度。
抗机械振动和冲击
振动频率:10Hz~60Hz,60Hz~500Hz。
振动峰振幅:0.14mm。
振动峰加速度:2g。
冲击峰加速度:10g。
防护等级:IP65。
绝缘电阻:>100MΩ(500VDC)(防雷除外)。
防雷保护(耐瞬变电压):6kV(1.2×50us),3000A,100 次冲击;6kV(8×20us),3000A,200 次冲击;
4kV(10×700us),260A,1000 次冲击。
密封性
变送器的测量部分在承受额定工作压力时保持密封状态,没有泄漏。
贮存温度/运输温度:-50℃~+85℃。
重量:约 3.0kg(不包括附件)。
WT3330 远传变送器概述
20
11、外形尺寸图
Z S M
Z S M
WT3330 远传变送器概述
21
Z S M
\"
Z S M
过程连接尺寸图
23
过程连接尺寸图
夹持式过程连接:
过程连接尺寸图
24
7.3.2 耦合式过程连接:
C3
63
70
78
92
支架
25
支架
一.管装支架
二.墙装支架
HHT375 手操器
26
HHT375 手操器
HHT375 手操器是支持 HART 协议的手持通信器,主要用于工业现场对 HART 智能仪表进行组态、
管理、维护、调整以及对运行过程中的过程变量的监测,功能全,兼容性好。
HHT375 手操器可以方便地接入 4mA~20mA /HART 协议仪表电流回路中,与 HART 协议仪表进行通
信,配置 HART 仪表的设定参数(如量程上下限等),读取仪表的检测值、设定值,可以对仪表进行
诊断和维护等。HHT375 手操器同时支持 HART 协议的点对点和多点通信方式。
HHT375 手操器可以在远端控制室或仪表
就地接入,单独对 HART 仪表进行通信操作。手操器可以并联在 HART 协议设备上,也可以并联在其
负载电阻(250Ω)上。连接时不必考虑引线的极性。
为了保证 HHT375 手操器通信正常,在回路中必须有 230Ω~ 600Ω的负载电阻。HHT375 手操器
不直接测量回路电流。
HHT375 手操器订货号:HHT375。
HART MODEM
我公司生产的 HART MODEM,符合 HART 协议,为标准的 FSK 方式,1200Hz 表示数据“1”,2200Hz
表示数据“0”,可以适用于所有的 HART 通信软件。
HART MODEM 工作时不需要专门的外接电源供电,只需与计算机的 COM/USB 口连接即可,使用方
便,是 HART 智能仪表设备与计算机通信的必备产品,是连接 HART 智能仪表设备与计算机的桥梁。
HART MODEM(COM)订货号:WTM-H-1;
HART MODEM(USB)订货号:WTM-H-2。
版 本 号:P 2025. 01. 07 上海威尔泰仪器仪表有限公司 印刷日期:2025. 01
上海威尔泰测控工程有限公司
地 址:上海市华哲路355弄8号 邮编:201611
电 话:86-21-67606565 传真:86-21-67601065
服务热线:800 820 6075 400 820 6075
网 址:http://www.welltech.com.cn
电子信箱:marketing@welltech.com.cn