HEBEI TLAOYUAN
闭式冷却塔系列产品
河北超远科技开发有限公司HEBEITIAOYUANSCIENCEANDTECHNOLOGYDEVELOPMENTCO.,LTD
公司名称:河北超远科技开发有限公司公司地址:河北省衡水市枣强县东外环中小企业创业园77号联系电话:13831823668 1863186729615350833305
迢远愿景 TIAOYUAN vision
Striving to be a centuy's standing enterprise with thoughts and cultural deposits
展望未来,我们与时俱进 Looking to the future, we keep pace with the times
历经风雨,根植燕赵,
今天的我们,任重而道远。
作为产品的生产企业,
通过积极研发,开拓创新,
生产更优质的玻璃钢产品;
作为客户的合作伙伴,
秉承诚实守信,
竭尽全力为客户提供周到的售前、售中和售后服务,
满足客户的需求,解决客户的问题;
河北迢远,心存感激,
实践着“发展企业、热心公益、回报社会”的企业使命..
Through wind and rain, rooted in Yanzhao,
Today, we have a long way to go.
As a manufacturer of products,
Through active research and development, pioneering innovation
Production of better quality FRP products;
As a partner of our customers
Be honest and trustworthy,
Make every effort to provide customers with thoughtful pre-sale, sale and after-sales service, Meet customer needs and solve customer problems;
Hebei TIAOYUAN, be grateful,
Practicing the enterprise mission of "developing enterprises, being enthusiastic about public welfare, and returning to society.
HEBEITIAOYUAN COMPANY PROFILE
企业简介
河北迢远科技开发有限公司坐落在中国玻璃钢基地县----枣强县经开区,是一家从事玻璃钢综合产品的开发、生产、销售、维修于一体的综合性企业,公司位于京九线旁,距大广高速仅10公里,紧邻S393省道,交通四通八达,运输便捷,地理位置优越。
公司主营产品有:玻璃钢风机、钢制风机、玻璃钢冷却塔、冷却塔填料、闭式冷却塔、玻璃钢缠绕管道、玻璃钢缠绕容器、玻璃钢化粪池、防腐工程、电缆桥架、水箱、通风柜、玻璃钢拉挤型材、玻璃钢电缆桥架、玻璃钢格栅、净化塔、脱硫塔、脱硝塔、环保净化设备、除尘净化设备、一体化预制泵站、玻璃钢拉挤系列产品、玻璃钢模压系列产品、工程橡胶制品等,及以上产品的售后服务及维修。
我们一如既往把高品质的产品和一流的服务奉献给广大用户为玻璃钢行业的发展做出应有的贡献。
公司秉承重合同、守信用,让客户满意的宗旨。我公司生产的玻璃钢系列产品覆盖全国20多个省、市、自治区,并出口南美洲、亚洲及非洲等国家,广泛应用于油田、化工、机械、造纸、电力、食品、排水、中央空调、纺织印染行业,深受用户好评。
公司成立以来发展迅速,有一套从产品设计、研发、到模具开发,原料加工,成品生产,品质检测等完善的生产流程,拥有先进而齐全的配套设备、技术力量雄厚、完善的管理体制以及生产工艺的不断提高和完善。
公司在发展的过程中,奉行“进取求实,诚信严谨”的方针,以技术为核心、视质量为生命、奉客户为上帝,竭诚为您提供性价比高的产品及无微不至的售后服务,愿意成为您可信赖的长期合作伙伴。
河北迢远科技开发有限公司,愿以先进的生产设备、雄厚的技术力量、优良的售后服务,竭诚与您合作。
COMPANY QUALIFICATION
BISHINILIULENGQUETA
FBN闭式逆流冷却塔
⊚ 产品优点
应用于流体冷却
对于用户来说,由于闭式冷却系统将工艺流体保持在一个清洁的闭合环路中,从而具有许多的操作上和维护上的优势。
保持工艺流体不受污染;
降低结垢的可能性,将系统效率提高到最大的程度;
降低系统能耗成本;
降低系统维护成本;
保证设备全年的可靠和高效的运行。
产品的定位:在成熟技术的基础上,一切创新措施完全因客户需求而制定,做得到客户首肯的产品和服务。
能够为用户准确选型,通过完备的理算系统以及广泛的用户群体,为我们积攒了丰富的经验。
从接到客户咨询到具体答复的过程快捷、客观,决不拖延时间;并作出最可行的解决方案。
在服务方面,我们能够比用户考虑得更细致,对于每一个用户,配有专职工程师跟踪服务。
工厂座落在河北省枣强县玻璃钢工业园区,区位的优势构筑了企业在人才、技术、供应链、物流等方面的优势。
本公司的产品(服务)对于客户的实用性以及潜在的价值是我们时刻所考虑的。
工作原理
FBN密闭式冷却塔将冷却塔和热交换器的功能有效地整合到了单台设备中,从而将工艺流体的温度保持在相当接近空气湿球温度的情况下。系统工作时,需要冷却的工艺流体在蛇形的热交换器盘管内部流动。外部有喷淋系统以持续湿润盘管表面。喷淋到盘管上的水流经一段具有高效冷却作用的散热片进行冷却后再落至集水盘中以再循环利用。系统采用了先进的逆流技术,空气同时吸入并通过盘管和散热片,使得一部分水蒸发。气流中所夹带的所有水分均由飞溅水挡水器进行回收,并送回至集水盘上。藉由蒸发,将热量从喷淋水中带走,进而冷却盘管中的工艺流体。在这一过程中,唯一“消耗”掉的水分量是蒸发为蒸汽的水分量加一小部分的排污水,而排污可以抑制再循环水中杂质的浓度。
密闭式冷却塔(又名蒸发式冷却器)与蒸发式冷凝器为同类产品,用于气体冷凝的称为蒸发式冷凝器,用于液体冷却的一般称闭式冷却塔(蒸发式冷却器),两者结构和标准略有不同,本刊主要介绍FBN密闭式冷却塔(逆流)
本产品与同类产品的最大区别是:根据蒸发冷的工作原理,在设计中使用两项专项技术,使换热效率提高了 1 0 % 以上;可节能 1 0 % 以上;并使水在蒸发时的结垢现象降低到了最低限度,通过工业运转得到了专家及用户的一致认可。
冷系统相比较:工艺温度降低 .5° 到 20° °,占用空间更小,能与一次流放系统相比较:减少对环境的不良影响,节约高达 95% 的冷却水。
降低安装费用:将冷却塔和热交换器的功能有效地整合到单台设备中。降低了管道和系统布置的复杂度。
与冷却塔/热交换器组合系统相比较:更接近空气湿球温度,并减小了结垢现象,提高了工艺的效率。
与开放式冷却塔相比较:不含污物的密闭式冷却能够大幅地降低工艺过程中的结垢现象,从而确保在长期运行下恒定的工艺性能。
减小了占用空间:密闭式冷却塔能够为设备安装腾出宝贵的空间。工艺负荷所需泵机和管道的尺寸减小。
{x} 密闭式冷却塔与其他塔类各种费用比较
由于密闭式冷却塔(A)、其它形式(B)两种方式在冷却形式上的不同,A方式的冷却效率大大提高,因此水费电费明显减少,维护更方便;投资费用方面,以前A方式往往高许多,近年来随着A方式在业内的普遍推广,解决了许多诸如技术、供应链等问题,造价也随之下降,两种方式2-3年运行的综合成本比较,A方式有更明显的优势。
风机:室外环境使用的三防专用风机,电机采用的防护等级为IP55级,绝缘等级为F级;轴流式风扇叶片;诱导型风筒减少空气回流,减少渗漏。
集水槽:倾斜设计,不锈钢滤网,补水(浮球阀或电子水位器)、溢流、排污。
散热层:PVC材料,降低喷淋水温,有利于防止盘管结垢,较低的喷淋水循环,更好的换热效率,有利于节约能源。
冷却盘管:铜管(T型):采用T2型优质紫铜管或不锈钢管,此关键部件,多年来一直采用名牌厂家的制品。
收水器:PVC材料制成的挡水板经过三次改变气流方向,最大限度地挡回排出空气中的水分,拆卸方便。
塔体外壳:FBN系列的标准用料为进口镀锌钢板,是耐腐蚀、阻热性能最强的镀锌板之一,普通钢板静电喷塑。根据特殊需要,也可有采用304或316不锈钢板。
控制系统:电器元件采用进口品牌。可选配智能变频,设备的风机、水泵与主机的系统联合控制。
⊚ 产品显著特点
原材料
无论产品的技术含量多少,是否拥有很多专利权好,产品质量的关键还是在于原材料的定位,产品卓越的性价比才是客户价值的直接表现。我公司产品在各环节使用的原材料均为行业名牌,部分进口。
防止结垢
传统的冷却设备在防止冷却盘管结垢方面,一直没有很好的办法。但是本产品在解决冷却盘管结垢方面得到了客户的一致好评,也是我公司产品的最大特点。
较低的水温使得容易形成水垢的钙离子、镁离子等不容易附着在管子上,避免了堆积成垢,内部空间布置的PVC散热层用于高温塔降低水温。
换热方式是通过管子湿润表面的显热和吸热管壁的潜热来换热,这样的换热方式有利于防止结垢。
设备选型方法
选择密闭式冷却塔,必须已知所需冷却介质的流量。温降、比热、以及用户所在地湿球温度。
1、确定设计条件冷却介质温降,流量,比热。
2、计算出负荷Q = Cp. rVs .△T(Q:热负荷KW,CP:定压比热KJ/kg℃,r:比重量kg/h,VS:水流量\mathsf{m}^{3}/\mathsf{h} , \triangle T:介质温差 {°C}_{\prime} )
3、求出校正系数(表一)
4、求出修正后的负荷量(kw)
5、运用表二选择闭式冷却塔,选择标准排热量应大于计算出的校正负荷量。
注:在不同地区,不同条件下,闭式冷却塔的散热量与当地环境湿球温度关系很大,具体请与我公司联系。
选型实例:
已知:介质 \mathsf{H}_{2}\mathsf{O} ,比热4.186KJ/kg. ^\circ C ,流量100t/h,进水温度 37°C ,出水温度 32°C ,湿球温度 28°C 。
| 湿球温度:28℃ | |
| 温降 | |
| 逼近度 | 456789101112131415161718 |
| 4 | |
| 5 | .72.68.63.59.56.53.50.48.45.43.41.39.38.37.36 |
| 6 | .65.61.58.54.51.48.45.43.41.39.38.37.35.34.33 |
| 7 | .59.56.53.50.47.44.42.40.38.36.35.34.33.32.31 |
| 8 | |
| 9 | .50.48.45.43.40.38.36.35.34.32.31.30.29.28.27 |
| 10 | .47.43.42.39.37.36.34.33.31.30.29.28.27.27.26 |
| 11 | |
| 12 | .40.38.36.33.33.32.30.29.28.27.26.25.24.23.22 |
| 13 | .38.36.34.33.31.30.28.28.26.25.24.23.22.22.21 |
| 14 | |
选择设备程序:
1、计算出负荷 583.3kw2、求出修正系列 0.773、583.3kwx0.77 449kw4、从表二中选择标准排热量大于449kw的型号5、故选型 FBN-80
表二
| 型号 | 排热量(kw) | 型号 | 排热量(kw) | 型号 | 排热量(kw) |
| FBN-6 | 35 | FBN-60 | 348 | FBN-200 | 1162 |
| FBN-10 | 58 | FBN-70 | 406 | FBN-250 | 1453 |
| FBN-15 | 87 | FBN-80 | 465 | FBN-300 | 1744 |
| FBN-20 | 116 | FBN-100 | 581 | FBN-350 | 2034 |
| FBN-30 | 174 | FBN-125 | 726 | FBN-400 | 2325 |
| FBN-40 | 232 | FBN-150 | 872 | FBN-450 | 2616 |
| FBN-50 | 295 | FBN-175 | 1017 | FBN-500 | 2906 |
技术参数表
| 型号 | 冷却水量m/h | 风 机 | 喷淋泵 | 进、出 水口径 DN | 工作 水压 Mpa | 重量 kg | 外形尺寸 长×宽×高 mm | ||||
| 37-32℃ | 40-32℃ | 55-35℃ | 功率kw | 风量m/h | 功率kw | 水量m/h | |||||
| FBN-6 | 9 | 3.8 | 1.5 | 0.45 | 10000 | 0.75 | 11 | 65 | 0.15 | 287 | 1350×1000×1850 |
| FBN-10 | 10 | 6.3 | 2.5 | 0.75 | 13000 | 0.75 | 11 | 65 | 0.2 | 402 | 1500×1000×1850 |
| FBN-15 | 15 | 9.4 | 3.8 | 0.9 | 20000 | 1.1 | 22 | 65 | 0.2 | 465 | 2350×1000×1850 |
| FBN-20 | 20 | 12.5 | 5 | 0.9 | 20000 | 1.1 | 22 | 65 | 0.25 | 490 | 2350×1000×1920 |
| FBN-30 | 30 | 18.8 | 7.5 | 1.5 | 26000 | 1.5 | 25 | 65 | 0.25 | 650 | 2850×1250×2100 |
| FBN-40 | 40 | 25 | 10 | 2.6 | 33600 | 1.1 | 22 | 80 | 0.3 | 750 | 2850×1250×2300 |
| FBN-50 | 50 | 31 | 12.5 | 2.6 | 33600 | 1.5 | 25 | 80 | 0.3 | 980 | 2850×1250×2650 |
| FBN-60 | 60 | 37.5 | 15 | 3.6 | 40000 | 1.5 | 25 | 80 | 0.3 | 1050 | 2850×1250×2800 |
| FBN-70 | 70 | 43.8 | 17.5 | 3.6 | 40000 | 2.2 | 44 | 100 | 0.35 | 1280 | 2850×1500×2750 |
| FBN-80 | 80 | 50 | 20 | 3 | 52000 | 2.2 | 44 | 100 | 0.35 | 1450 | 2850 × 1660 × 2990 |
| FBN-100 | 100 | 62.5 | 25 | 3 | 52000 | 2.2 | 44 | 100 | 0.35 | 1945 | 2850×1660×2990 |
| 型号 | 冷却水量m/h | 喷淋泵 | 进、出 水口径 | 工作 水压 | 重量 kg | 外形尺寸 长×宽×高 | ||||
| 37-32℃|40-32℃55-35℃ | 功率kw | 风机 风量 m*/h | 功率kw | 水量 m°/h | ||||||
| FBN-125 | 125 | 78 | 31.3 5.2 | 67200 | 4 | 88 | 125 | 0.35 | 2450 | 3150 × 1780 × 2950 |
| FBN-150 | 150 | 93.8 | 37.5 7.2 | 80000 | 4 | 88 | 150 | 0.35 | 2850 | 3350 × 1880 × 2960 |
| FBN 175 | 175 | 109 | 43.8 7.8 | 100800 | 4 | 88 | 150 | 0.35 | 3150 | 3950 ×1880×3100 |
| FBN 200 | 200 | 125 | 50 10.8 | 120000 | 4 | 140 | 200 | 0.35 | 3600 | 4350× 2080 × 3100 |
| FBN 250 | 250 | 156 | 62.5 14.4 | 160000 | 4 | 140 | 200 | 05 | 4900 | 4850 × 2160 × 3300 |
| FBN 300 | 300 | 187 | 75 17.6 | 196000 | 4 | 140 | 200 | 5700 | 5250×2310 ×3700 | |
| FBN 350 | 350 | 219 | 87.5 15.6 | 201600 | 4×2 | 176 | 15 X | 0.5 | 6300 | 5850 × 2310 × 3700 |
| FBN 400 | 400 | 250 | 100 21.6 | 240000 | 200 | 150 2 | 0.6 | 7200 | 6000× 2440 × 3800 | |
| FBN 450 | 450 | 281 | 113 25.2 | 280000 | ×2 | 200 | 200 2 | 0.6 | 9450 | 6000 × 2440 × 3800 |
| FBN- -500 | 500 | 313 | 125 28.2 | 320000 | 7.5×2 | 298 | 200 × 2 | 0.6 | 9800 | 5000 × 4850 × 3550 |
| FBN-550 | 550 | 344 | 138 32 | 356000 | 7.5×2 | 298 | 200 × 2 | 0.6 | 10200 | 5600× 4850 × 3550 |
设备基础
FBN密闭式冷却塔应采用“工”字钢支撑梁或混凝土支撑梁,支撑梁应置于闭式冷却塔底部圈梁下部或定位折边下部,与设备长度相等。支撑梁应有不小于700mm的高度,以便维修人员能进行设备底部检修或进行房顶维护。
密闭式冷却塔底部折边上有直径14mm的安装孔。
喷淋水泵也要做钢支撑或混凝土支撑。
| 型号 | A (mm) | B(mm) | C (mm) | D(mm) | E(mm) |
| FBN-6 | 1350 | 1000 | 500 | ||
| FBN-10 | 1500 | ||||
| FBN-15 | 2350 | ||||
| FBN-20 FBN-30 | 2350 | ||||
| FBN-40 | 2850 | 1250 | 500 | 600 | 700 |
| FBN-50 | |||||
| FBN-60 | 1500 | ||||
| FBN-70 | 1660 | 750 | |||
| FBN-80 | |||||
| FBN-100 FBN-125 | |||||
| 3150 3350 | 1780 1880 | 550 | |||
| FBN-150 | 3950 | ||||
| FBN-175 FBN-200 | 4350 | 2160 | 950 | ||
| FBN-250 | 4850 | ||||
| FBN-300 | 5250 | 2310 | |||
| FBN-350 | 5850 | ||||
| FBN-400 | 2440 | ||||
| FBN-450 | 6000 | 4850 | 1200 | ||
| FBN-500 | 5000 | ||||
| FBN-550 | 5600 |
工程设计要点
为保证设备可靠地运行,工程技术人员应充分考虑下面的工程设计要点。
安装位置
FBN密闭式冷却塔风的走向为下箱体两侧进风顶部排风,为保证设备正常运行,进风和排风均应有 足够的空间,确保通畅。
当FBN密闭式冷却塔的一个进风侧靠近高墙时,这一侧的高墙间距不应小于1.2米,其它的三面也要留出足够的空间,便于维护。
当FBN密闭式冷却塔多台并联安装时,两台闭式冷却塔相对的进风侧面间距应不小于2米。
FBN密闭式冷却塔应优先考虑安装到泵房的顶部或楼顶,远离墙壁和障碍物,可以确保有良好空气流通,并降低噪声对环境的影响。
配 管
FBN密闭式冷却塔管道系统设计和安装应符合一般的工程规范。
在多机组的系统中,管道布置应对称,管道尺寸应满足流量和水泵扬程的要求。标准的FBN密闭式冷却塔应设膨胀水箱(贮水箱),用子吸收液体的膨胀,分离并放出封闭回路中的空气。
热交换管组中的水能够放尽。要在管道系统的高处设置放气阀,在低端设放水阀。
必要时管道应设置恰当的吊钩和支架。不可在换热器的连接处外力加任何负载,也不可将管道支架固定在密闭式冷却塔的框架上。
对换热管组的防冻保护
如机组安装在寒冷地区,当环境温度低于0℃且循环流体没有热负荷时会发生管组结冰现象,必须对热交换管组和循环水系统进行防冻保护。防止热交换管组结冻最简单的办法是使用防冻液(例如乙二醇溶液)。也可在管组上附加热负荷,使在停机时,水温不致跌到 1 0°C 以下。另外,管组内必须保持一个最小流量。
排空封闭系统内的液体只可作为一种应急的防冻措施。
多次进行排空操作会导致管组管子内侧的腐蚀现象加剧,尽量不要用这种措施。
对水箱的防冻保护
当环境温度低于冰点,冷却设备在停机情况下,水箱内的水就必须采取防冻措施。
采用放置在室内的远置贮水箱是最简单的方法;或者通过浸没式电加热器。
蒸汽(热水)加热管组来为水箱中的水提供辅助加热。
所有在停止运行期间不排水的外露水管和补水管线应该采用必要的保温措施。
水处理
水处理包括防腐蚀、防结垢、防藻类的滋生三个方面内容。
首次注入水和补充水应根据水质分析报告确定水处理措施。最终的水质指标应控制在以下范围内:PH值7.0-8.5;总硬度 <1 5\mathsf{m g} (当量)/L;氯根 <1 5\mathsf{m g}/\mathsf{L} ;浊度 <20\mathsf{m g}/\mathsf{L} ;异养菌 <20 个/ml;
采用化学品的水处理,该化学品必须不会与设备构件发生反应。
应定期检查循环管路内、管组外及淋水填料表面。
流体与管组材质的兼容性
被冷却的液体必须与管组材质具有兼容性,否则会腐蚀和破坏管组。某些特定的流体可能要求对管组内侧不定期地进行压力清洗,在这种情况下,管路布置时应考虑这种需求,要便于排放清洗液。
安全性
本设备的运行、维护和修理只能由合格的人员来进行,在搬运、起吊、安装、操作、维护和修理本设备时,必须采取正确的谨慎的态度,工作步骤和工具,以防止人员受伤或财产损失。
容量控制
风机起停控制是最简单的容量控制的方法,通风量控制的级数可以通过控制风机启、停的数量来实现,此方式具有相当显著的节能效果。
警告:快速的起停周期性工作可能造成风机电机的过热现象,我们建议控制装置设置在每小时最多起停6次的设定值。
噪声等级
工程技术人员必须考虑到冷却塔周围环境对冷却塔噪音的要求,并确定降噪措施。
系统循环图
运行原理
钢厂及铸造厂
淬火槽冷却、轧钢机冷却、感应炉冷却、连铸冷却。
工业流体
液压油、电镀溶液、淬火油。
制造业
空气压缩机水套冷却、注塑模具冷却、变压器冷却、发动机水套冷却。
空调系统
水源式热泵系统、机房空调系统、辅助供冷系统。
其他应用实例
发电机组水冷却、锅炉蒸气冷凝、玻璃熔窑冷却、注塑机冷却......
关于流体冷却,气体冷凝的诸多领域里,我们能为您提供更多的解决方案。
创新·专业·品质·诚信
StreetParty Committee Party workmanual A seriesof books on the party'sconstruction of culture
公司名称:河北超远科技开发有限公司公司地址:河北省衡水市枣强县东外环中小企业创业园77号联系电话:138318236681863186729615350833305