TMV-Vd255W/N1-C1
EEVkits
Outdoor unit connects to wallmounted indoor units with EEV kits and Ybranch -Method 3 One out door unit can connect 1O indoor units.
| Branch Box | TMV-V2P2BD/ N1DY(E) | TMV-V2P1BD/ N1DY(E) | TMV-V3P3BD/ N1DY(E) | TMV-V3P2BD/ N1DY(E) | TMV-V22-50G/ N1DY-B(E) | TMV-V56-80G/ N1DY-B(E) |
| Max.number of indoor unit | 2 | 2 | 3 | 3 | 1 | 1 |
| Appearance |
Full DC Inverter Technology
Byadopting full DC inverter technologyto achieve 30 % energy-saving compared with AC motor.
DC Inverter Compressor
The DC inverter motor with concentrated winding ensure higher efficiency.
Guarantees the reliabilityand energy savingof the refrigeration system.
Self-developed TEC Control
Highlyintegrated toachieve three drives onone board,improving system response speedand enhancingantiinterference ability.
Benefit
No easily worn parts,high energy conversion,Shorter wiring,No external communication lines TEC:TCL Electric Control
Flexible lnstallation
The Mini VRF provides a total piping length possibilityof8Om,a maximum height difference between outdoorand indoorunitsof 3Om.These generousallowances facilitateanextensive arrayof system designs.
Al Energy saving
Our system achieves an additional 20 % energy savings on top of full DC inverter technology. ThisisaccomplishedviaAl-drivenadaptive control with 0 . 1 H z precision for optimal lowpowerefficiency.
High VEEC Value
The Victorian Energy Upgrades(VEU) program assists householdsand businessesto reduce their energybillsand greenhouse gasemissions byproviding financial incentives to install energyefficient equipmentand appliances.
The VEEC value up to 1O6,higher than Midea 105,userscan receivemore subsidies from the Australian government.
| VEU Climatic Region | Heating capacity(kW) | Cooling capacity(kW) | VEEC |
| Forupgrades in Metropolitan | 25.5 | 21 | 106 |
| Victoria-Climatic region mild | |||
| For upgrades in Regional Victoria-Climatic region mild | 25.5 | 21 | 106 |
Wide Operation Temperature Range - 1 0 ^ { \circ } C - 5 6 ^ { \circ } C
Coolingsteadilyfrom-1Oto56 ^ { \circ } { \mathsf C } whichmeetvariousofworkingconditionsand scenarios.
Wide Voltage Range Operation
·Mini VRF ODU operation voltage rangeis from 198\~264V,whichiswider thanstandard. ·System can operate stablyand reliable even in unstable powersupplyarea.
\*Operation voltage range:198-264V
4-stage Oil Return Technology
4-stageoilcontroltechnology,ensurethatcompressoralways hasenoughoilforlubrication toextendcompressol lifespan.
Level 1:Compressor internal oil separate.
Level2:Compressor external oil separate.
Level3:Automatic oilbalance system improves thecompressorreliability. Level 4:High-efficiency centrifugal oil separator,oil return efficiency up to 9 9 %
Dust Removing Design
Fanmotor forward and reverse to remove dust on fins keeps condenser fins good performance, enhance stability.
\*Afterself-cleanmode,the outdoor fanwill reverseautomatically
PreciseTemperature Control
According totheset temperature,thesystemwillcontroltherefrigerantflowpreciselyandadjust theevaporating/ condensing temperature automatically through the EEVand temperature sensor,whichdecrease the temperature fluctuation to make sure the room temperature more confortable.
Wide Angle Air Supply
With up-down,left-right louver swing,cover more area to achieve mort comfort.
Intelligent Defrosting Technology
Intelligent defrosting technology ensure reduces defrosting timeand provides usermore comfortable.
Noise Reduction
The indoor units usesa low noise DC motor and external EEVdesign to reduce the noise generated during the operation,thenoiseisaslowas22dB(A),likethesoundofleaves faling,tocreateaquietandcomfortable home environment.
TCLTMV-Vd255W/N1-C1
Intelligent Control
TCL Management System
Centralized control of indoorunitsand outdoorunits
Monitor thedetailed workingstatue of both indoorand outdoor units
DataAnalysis
Operatingdatarecords Recordsandalarmsforerrorsand faults History of operating schedules
Estimate of energy consumption
Running cost is calculated according to the running time,refrigerant flow,etc.
Detail reportsand bills of energy consumption are available
Schedule function
Annual,monthlyanddailyschedulesareavailable Schedulesof individual ormultipleunitscanbeset, whichisconvenient for centralized control
High-end wired controller
Voicecontrol,iotiootrolantiroutnthi
Centralized Controller
Highresolutiondisplay,Elegant&friendlyUdesign,ndividual,groupcontrol,Dailyweekly,olidayhdule Data import& export, Energy consumption analysis
TCL WiFi Control System
Connect the device with APP by one click. Remotely turn on/off and set schedule or timer.Monitor running datas and operation history.
BMS Control System
Monitoring andcontrolofTCL's MiniVRFairconditionerscanbe integrated into building management systems enabling airconditioning tobemonitoredalongsidelighting,elevator,fire,accessand securitysystems.TCL's gateway devices provide full compatibility with the leading BMS protocols: BACnet & Modbus.
Maintenance
Using PC and RS485protocal converter connect with ODU which could helps engineers monitor mini VRF system operation datas quichkly,find the cause of the malfunction and resolve the issue.
Outdoor PCB has USB port to update new program which convenient service engineers,Midea dosen't havethisaftersalesport.
Branch kit installation
Choosea location thatisconvenient forinstallation.
Don't install the EEVkit outside or rooftop in direct sunlight
Keepawayfrombedroom,it'sbetterinstallinsidethe corridor or washroom ceiling
Keepawayfrom heatsources(suchassmoke,open flames)orharmfulpollution belowit.
TCLTMV-Vd255W/N1-C1
Installation
Installation Space
1.Hoisting Installation Drawing of Branch Box(Unit: mm)
2.Wall-Mounted Installation Drawing of Branch Box(Unit:mm)
Installation Direction for Wall-Mounted Instaliation
Orientation 1: Leftward Connection√
The connecting wires of the electronic expansion valveshallbe formedintoadownward U-bend to ensure thatthewiring hole of thebranchboxis not the lowest point.
Orientation 2: Rightward Connection√
The connecting wires of the electronic expansion valveshallbe formed intoadownward U-bend to ensurethatthewiring hole of the branch boxis not the lowest point.
Orientation 3: Upward Connection ×
Orientation 4: Downward Connection√
The connecting wires of the electronic expansion valveshallbe formed intoadownwardU-bend to ensurethatthewiring hole ofthe branchbox is not the lowest point.