Chainflex Control Cable
Certification
Number of cores 2C 3C 5C 6C
Core design
Number of cores 7C 8C 16C 18C
Core design
Conductor
Insulation
Core structure
Cfrip
Filer
Jacket
Jacket clor
Marking E145335 AWM STYLE 2129X XXAWG 105℃ X00V AWM I A 105℃ X00V FT2 DATAFIELD
In the 2129X, X can be 6 or 7.; In the XXAWG, XX refers to the wire number. ;In the X00V, X can be 3 or 6.
Marking clor
Ambient temperature
Rated voltage
Dielectric strength
Spark Test
Insulation resistance
Flame test
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 1/4
●For heaviest duty applications ●TPE outer jacket ●Oil and bio-oil resistant ●PVC-free
●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Specifications
Cross Section
Stranded conductor in especially bending-resistant version
consisting of bare copper wires
Cores<0.75mm²:Colour code in accordance with DIN 47100
Tensile stress-resistant centre element
12C
Insulation clor
E145335: UL21296/UL21297
4C
Mechanically high-quality TPE mixture.
Cores≥0.75mm²:Black cores with white numbers, one green-yellow core
Cores wound in a layer with especially short pitch length
Tear strip for faster cable stripping
Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture
White
-40℃ ~ +105℃
Cores<0.50mm²:300V ; Cores≥0.50mm²:600V
No cracking (AC 2000V/1Minute)
TRE.XX.XX
3.0 KV Insulation/Jacket
≥10MΩ
HB/FT2
Steel-blue (similar to RAL 5011)
c
Chainflex Control Cable
Chainflex Control Cable
Nominal cross-sectional
area
Outer diameter(d)
max
Copper index Weight Max.conductor
resistanceat 20℃
Max.current
rating at 30℃
mm² mm kg/km kg/km Ω/km A
TRE.02.02 2x0.25 (24AWG) 4.5 5 18 79.0 5
TRE.02.03 3x0.25 (24AWG) 5.0 8 22 79.0 5
TRE.02.06 6x0.25 (24AWG) 5.5 15 36 79.0 5
TRE.02.07 7x0.25 (24AWG) 6.5 18 43 79.0 5
TRE.02.08 8x0.25 (24AWG) 6.5 20 49 79.0 5
TRE.02.12 12x0.25 (24AWG) 8.0 30 71 79.0 5
TRE.02.18 18x0.25 (24AWG) 9.0 45 100 79.0 5
TRE.03.04 4x0.34 (22AWG) 5.0 14 31 57.0 7
TRE.03.05 5x0.34 (22AWG) 5.5 17 36 57.0 7
TRE.03.06 6x0.34 (22AWG) 6.0 21 43 57.0 7
TRE.03.08 8x0.34 (22AWG) 7.0 28 57 57.0 7
TRE.05.02 2x0.50 (20AWG) 5.0 10 28 39.0 10
TRE.05.03 3x0.50 (20AWG) 5.5 15 34 39.0 10
TRE.05.04 4x0.50 (20AWG) 6.0 20 41 39.0 10
TRE.05.05 5x0.50 (20AWG) 6.5 25 50 39.0 10
TRE.05.07 7x0.50 (20AWG) 7.5 35 69 39.0 10
TRE.05.12 12x0.50 (20AWG) 10.0 60 123 39.0 10
TRE.05.18 18x0.50 (20AWG) 11.5 90 179 39.0 10
TRE.07.04 4G0.75 (19AWG) 6.5 30 56 26.0 14
TRE.07.05 5G0.75 (19AWG) 7.0 38 69 26.0 14
TRE.07.07 7G0.75 (19AWG) 8.0 53 94 26.0 14
TRE.07.12 12G0.75 (19AWG) 11.0 90 176 26.0 14
TRE.10.03 3G1.0 (18AWG) 6.0 30 54 19.5 17
TRE.10.04 4G1.0 (18AWG) 6.5 40 68 19.5 17
TRE.10.05 5G1.0 (18AWG) 7.5 50 84 19.5 17
TRE.10.12 12G1.0 (18AWG) 12.0 120 212 19.5 17
TRE.10.18 18G1.0 (18AWG) 14.0 179 303 19.5 17
TRE.15.02 2x1.5 (16AWG) 6.5 30 55 13.3 21
TRE.15.04 4G1.5 (16AWG) 7.5 60 90 13.3 21
TRE.15.05 5G1.5 (16AWG) 8.0 75 111 13.3 21
TRE.15.07 7G1.5 (16AWG) 9.5 104 159 13.3 21
TRE.15.12 12G1.5 (16AWG) 13.0 178 280 13.3 21
TRE.25.04 4G2.5 (14AWG) 9.0 100 144 8.0 30
TRE.25.05 5G2.5 (14AWG) 9.5 124 176 8.0 30
TRE.25.07 7G2.5 (14AWG) 12.0 174 253 8.0 30
TRE.40.04 4G4.0 (12AWG) 10.5 159 212 5.0 37
TRE.60.04 4G6.0 (10AWG) 12.0 238 308 3.3 53
TRE.60.05 5G6.0 (10AWG) 13.0 297 378 3.3 53
G=with green-yellow earth core ; x=withou earth core
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 2/4
TRE.XX.XX
●For heaviest duty applications ●TPE outer jacket ●Oil and bio-oil resistant ●PVC-free
●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Part Number
Part No
Chainflex Control Cable
Chainflex Control Cable
linear minimum 5 x OD
Bend radius Flexible minimum 4 x OD
Fixed minimum 3 x OD
linear -35 °C up to +105°C
Temperature Flexible -50°C up to+105°C(following DIN EN 60811-504)
Fixed -55°C up to +105 °C (following DIN EN 50305)
unsupported 10 m/s
Gliding 6 m/s
Travel distance
Torsion ± 90°, with 1 m cable length, Class 2
Double strokes 5million
Temperature,from/to [°C] R min.
[x d]
-35 ~ -25 6.8
-25 ~ +80 5
+80 ~ +105 6.8
Test bend radius approx. 18 - 125 mm
Test travel S approx. 1 - 15 m
Test duration minimum 3 - 5 million double strokes
Test speed approx. 0.5 - 2 m / s
Test acceleration approx. 0.5 - 1.5 m /s²
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 3/4
● Excellent oil resistance
● Compatible for indoor and outdoor use
7.5 8.5
● Suitable for short,very fast applications
TRE.XX.XX
Application
● Suitable for small space applications
Unsupported travels and up to 400m for gliding
applications, Class 6
●For heaviest duty applications ●TPE outer jacket ●Oil and bio-oil resistant ●PVC-free
●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Dynamic information
V max
Guaranteed service life according to guarantee conditions
7.5million 12.5million
Typical lab test setup for this cable series
R min.
[x d] R min.
[x d]
7.5 8.5
6 7
Chainflex Control Cable
Chainflex Control Cable
UV resistance High
Oil resistance
Silicone-free
Halogen-free Following DIN EN 60754
PTFE-free The design of these products does not contain PTFE
REACH In accordance with regulation (EC) No. 1907/2006 (REACH)
Lead-free Following 2011/65/EC (RoHS-II)
CE Following 2014/35/EU
Clean room
Conductor no
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 4/4
Yellow-brown
Brown-black
Yellow-blue
34
35 Green-black
Pink-brown
White
Brown
●For heaviest duty applications ●TPE outer jacket ●Oil and bio-oil resistant ●PVC-free
●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Properties and approvals
Yellow-red
Yellow
White-blue
Brown-blue
White-red
Brown-red
28
29
30
31
32
Violet
Grey-pink
Red-blue
According to ISO- tested by IPA Class 1 according to
DIN EN ISO 14644-1
Green-red
Grey
Pink
Blue
Red
Black
White-yellow
24
White-black
White-green
Brown-green
Green
White-grey
Grey-brown
25
26
27 Grey-green
Yellow-grey
Pink-green
33
Yellow-pink
Green-blue
Free from silicone which can affect paint adhesion
(following PV 3.10.7 – status 1992)
Colour code in accordance with DIN 47100
Colours according to DIN ISO 47100 Conductor no
19
20
21
22
23
White-pink
36
Oil-resistant (following DIN EN 60811-404) (following VDMA 24568with
Plantocut 8 S-MB tested by DEA),Class4
Colours according to DIN ISO 47100
Yellow-black
TRE.XX.XX
Chainflex Control Cable
Chainflex Control Cable
Certification
Number of cores 2C 3C 6C 8C
Core design
Conductor
Insulation
Insulation clor
Core structure
Filer
Jacket
Jacket clor
In the XXAWG, XX can be 20, 22, 24, or 26.
Marking clor
Ambient temperature
Rated voltage
Dielectric strength
Spark Test
Insulation resistance
Flame test
Nominal cross-sectional
area
Outer diameter(d)
max
Copper index Weight Max.conductor
resistanceat 20℃
Max.current
rating at 30℃
mm² mm kg/km kg/km Ω/km A
TRE.MAX.01.02 2x0.14 (26AWG) 4.5 4 18 140 2.5
TRE.MAX.01.03 3x0.14 (26AWG) 4.5 6 20 140 2.5
TRE.MAX.01.04 4x0.14 (26AWG) 5 7 25 140 2.5
TRE.MAX.01.08 8x0.14 (26AWG) 6.5 15 45 140 2.5
TRE.MAX.02.03 2x0.25 (24AWG) 5 10 29 88 5
TRE.MAX.02.04 4x0.25 (24AWG) 5.5 14 36 88 5
TRE.MAX.02.08 8x0.25 (24AWG) 7.5 29 68 88 5
TRE.MAX.03.04 4x0.34 (22AWG) 5 15 31 72 7
TRE.MAX.03.08 8x0.34 (22AWG) 7 29 56 72 7
TRE.MAX.05.02 2x0.50 (20AWG) 5 11 26 50 10
TRE.MAX.05.04 4x0.50 (20AWG) 5.5 21 39 50 10
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 1/3
E145335 AWM STYLE 21296 XXAWG 105℃ 300V AWM I A 105℃ 300V FT2 DATAFIELD
White
-40℃ ~ +105℃
300V
HB/FT2
Part No
Part Number
●For heaviest duty applications and especially small radius down to 3 x OD ●TPE outer jacket
●Oil and bio-oil resistant ●PVC and halogen-free ●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Specifications
No cracking (AC 2000V/1Minute)
3.0 KV Insulation/Jacket
≥10MΩ
Cross Section
Conductor consisting of a highly flexible special alloy
Mechanically high-quality TPE mixture.
TRE.MAX
Steel-blue (similar to RAL 5011)
E145335/UL21296
4C
Marking
Colour code in accordance with DIN 47100
Cores wound in a layer with especially short pitch length
Tensile stress-resistant centre element
Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture
c
Chainflex Control Cable
Chainflex Control Cable
linear minimum 3 x OD
Bend radius Flexible minimum 3 x OD
Fixed minimum 3 x OD
linear -35 °C up to +105°C
Temperature Flexible -50°C up to+105°C(following DIN EN 60811-504)
Fixed -55°C up to +105 °C (following DIN EN 50305)
unsupported 10 m/s
Gliding 6 m/s
Travel distance
Torsion ± 90°, with 1 m cable length, Class 2
Double strokes 5million
Temperature,from/to [°C] R min.
[x d]
-35 ~ -25 4
-25 ~ +80 3
+80 ~ +105 4
Test bend radius approx. 15 - 28 mm
Test travel S approx. 1 - 15 m
Test duration minimum 3 - 5 million double strokes
Test speed approx. 0.5 - 2 m / s
Test acceleration approx. 0.5 - 1.5 m /s²
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 2/3
●For heaviest duty applications and especially small radius down to 3 x OD ●TPE outer jacket
●Oil and bio-oil resistant ●PVC and halogen-free ●Low-temperature-flexible ●Hydrolysis and microbe-resistant
● Suitable for short,very fast applications
Short, very fast applications with small radius and restricted
installation space, Class 5
7
Dynamic information
7
5 6
6
V max
Guaranteed service life according to guarantee conditions
40million 100million
Typical lab test setup for this cable series
R min.
[x d] R min.
[x d]
6
● Excellent oil resistance
● Compatible for indoor and outdoor use
TRE.MAX
Application
● Suitable for small space applications
Chainflex Control Cable
Chainflex Control Cable
UV resistance High
Oil resistance
Silicone-free
Halogen-free Following DIN EN 60754
PTFE-free The design of these products does not contain PTFE
REACH In accordance with regulation (EC) No. 1907/2006 (REACH)
Lead-free Following 2011/65/EC (RoHS-II)
CE Following 2014/35/EU
Clean room
Conductor no
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 3/3
White
Brown
Yellow-red
Yellow
White-blue
Brown-blue
White-red
Brown-red
28
29
30
31
32
Violet
Grey-pink
Red-blue
White-green
Brown-green
Green
Yellow-brown
Brown-black
White-black
Green-black
Yellow-black
Grey-green
Yellow-grey
Pink-green
Yellow-pink
Green-blue
Free from silicone which can affect paint adhesion
(following PV 3.10.7 – status 1992)
Colour code in accordance with DIN 47100
Colours according to DIN ISO 47100 Conductor no
19
20
21
22
23
Oil-resistant (following DIN EN 60811-404) (following VDMA 24568with
Plantocut 8 S-MB tested by DEA),Class4
According to ISO- tested by IPA Class 1 according to
DIN EN ISO 14644-1
Green-red
36
White-grey
Grey-brown
25
26
27
Colours according to DIN ISO 47100
TRE.MAX
Grey
Pink
Blue
Red
Black
White-yellow
24
Yellow-blue
White-pink
Pink-brown
33
34
35
●For heaviest duty applications and especially small radius down to 3 x OD ●TPE outer jacket
●Oil and bio-oil resistant ●PVC and halogen-free ●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Properties and approvals
Chainflex Control Cable
Chainflex Control Cable
Certification
Number of cores 2C 3C 5C 6C
Core design
Number of cores 7C 8C 16C 18C
Core design
Conductor
Insulation
Core structure
Cfrip
Filer
Jacket
Jacket clor
Marking
In the 2129X, X can be 6 or 7.; In the XXAWG, XX refers to the wire number. ;In the X00V, X can be 3 or 6.
Marking clor
Ambient temperature
Rated voltage
Dielectric strength
Spark Test
Insulation resistance
Flame test
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 1/4
Cores<0.50mm²:300V ; Cores≥0.50mm²:600V
No cracking (AC 2000V/1Minute)
TRE.UL.XX.XX
●For heaviest duty applications ●TPE outer jacket ●Oil and bio-oil resistant ●PVC-free
●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Specifications
Cross Section
Stranded conductor in especially bending-resistant version
consisting of bare copper wires
Cores<0.75mm²:Colour code in accordance with DIN 47100
Tensile stress-resistant centre element
12C
Insulation clor
E145335: UL21296/UL21297
4C
Mechanically high-quality TPE mixture.
Cores≥0.75mm²:Black cores with white numbers, one green-yellow core
Cores wound in a layer with especially short pitch length
Tear strip for faster cable stripping
E145335 AWM STYLE 2129X XXAWG 105℃ X00V AWM I A 105℃ X00V FT2 DATAFIELD
Low-adhesion, extremely abrasion-resistant and highly flexible TPE mixture
3.0 KV Insulation/Jacket
≥10MΩ
HB/FT2
Slate grey (similar to RAL 7015)
White
-40℃ ~ +105℃
c
Chainflex Control Cable
Chainflex Control Cable
Nominal cross-sectional
area
Outer diameter(d)
max
Copper index Weight Max.conductor
resistanceat 20℃
Max.current
rating at 30℃
mm² mm kg/km kg/km Ω/km A
TRE.UL.02.02 2x0.25 (24AWG) 4.5 5 18 79.0 5
TRE.UL.02.03 3x0.25 (24AWG) 5.0 8 22 79.0 5
TRE.UL.02.06 6x0.25 (24AWG) 5.5 15 36 79.0 5
TRE.UL.02.07 7x0.25 (24AWG) 6.5 18 43 79.0 5
TRE.UL.02.08 8x0.25 (24AWG) 6.5 20 49 79.0 5
TRE.UL.02.12 12x0.25 (24AWG) 8.0 30 71 79.0 5
TRE.UL.02.18 18x0.25 (24AWG) 9.0 45 100 79.0 5
TRE.UL.03.04 4x0.34 (22AWG) 5.0 14 31 57.0 7
TRE.UL.03.05 5x0.34 (22AWG) 5.5 17 36 57.0 7
TRE.UL.03.06 6x0.34 (22AWG) 6.0 21 43 57.0 7
TRE.UL.03.08 8x0.34 (22AWG) 7.0 28 57 57.0 7
TRE.UL.05.02 2x0.50 (20AWG) 5.0 10 28 39.0 10
TRE.UL.05.03 3x0.50 (20AWG) 5.5 15 34 39.0 10
TRE.UL.05.04 4x0.50 (20AWG) 6.0 20 41 39.0 10
TRE.UL.05.05 5x0.50 (20AWG) 6.5 25 50 39.0 10
TRE.UL.05.07 7x0.50 (20AWG) 7.5 35 69 39.0 10
TRE.UL.05.12 12x0.50 (20AWG) 10.0 60 123 39.0 10
TRE.UL.05.18 18x0.50 (20AWG) 11.5 90 179 39.0 10
TRE.UL.07.04 4G0.75 (19AWG) 6.5 30 56 26.0 14
TRE.UL.07.05 5G0.75 (19AWG) 7.0 38 69 26.0 14
TRE.UL.07.07 7G0.75 (19AWG) 8.0 53 94 26.0 14
TRE.UL.07.12 12G0.75 (19AWG) 11.0 90 176 26.0 14
TRE.UL.10.03 3G1.0 (18AWG) 6.0 30 54 19.5 17
TRE.UL.10.04 4G1.0 (18AWG) 6.5 40 68 19.5 17
TRE.UL.10.05 5G1.0 (18AWG) 7.5 50 84 19.5 17
TRE.UL.10.12 12G1.0 (18AWG) 12.0 120 212 19.5 17
TRE.UL.10.18 18G1.0 (18AWG) 14.0 179 303 19.5 17
TRE.UL.15.02 2x1.5 (16AWG) 6.5 30 55 13.3 21
TRE.UL.15.04 4G1.5 (16AWG) 7.5 60 90 13.3 21
TRE.UL.15.05 5G1.5 (16AWG) 8.0 75 111 13.3 21
TRE.UL.15.07 7G1.5 (16AWG) 9.5 104 159 13.3 21
TRE.UL.15.12 12G1.5 (16AWG) 13.0 178 280 13.3 21
TRE.UL.25.04 4G2.5 (14AWG) 9.0 100 144 8.0 30
TRE.UL.25.05 5G2.5 (14AWG) 9.5 124 176 8.0 30
TRE.UL.25.07 7G2.5 (14AWG) 12.0 174 253 8.0 30
TRE.UL.40.04 4G4.0 (12AWG) 10.5 159 212 5.0 37
TRE.UL.60.04 4G6.0 (10AWG) 12.0 238 308 3.3 53
TRE.UL.60.05 5G6.0 (10AWG) 13.0 297 378 3.3 53
G=with green-yellow earth core ; x=withou earth core
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 2/4
TRE.UL.XX.XX
●For heaviest duty applications ●TPE outer jacket ●Oil and bio-oil resistant ●PVC-free
●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Part Number
Part No
Chainflex Control Cable
Chainflex Control Cable
linear minimum 5 x OD
Bend radius Flexible minimum 4 x OD
Fixed minimum 3 x OD
linear -35 °C up to +105°C
Temperature Flexible -50°C up to+105°C(following DIN EN 60811-504)
Fixed -55°C up to +105 °C (following DIN EN 50305)
unsupported 10 m/s
Gliding 6 m/s
Travel distance
Torsion ± 90°, with 1 m cable length, Class 2
Double strokes 5million
Temperature,from/to [°C] R min.
[x d]
-35 ~ -25 6.8
-25 ~ +80 5
+80 ~ +105 6.8
Test bend radius approx. 28 - 125 mm
Test travel S approx. 1 - 15 m
Test duration minimum 3 - 5 million double strokes
Test speed approx. 0.5 - 2 m / s
Test acceleration approx. 0.5 - 1.5 m /s²
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 3/4
TRE.UL.XX.XX
● Suitable for short,very fast applications
Application
● Suitable for small space applications
Unsupported travels and up to 400m for gliding
applications, Class 6
●For heaviest duty applications ●TPE outer jacket ●Oil and bio-oil resistant ●PVC-free
●Low-temperature-flexible ●Hydrolysis and microbe-resistant
V max
Guaranteed service life according to guarantee conditions
7.5million 10million
Typical lab test setup for this cable series
R min.
[x d] R min.
[x d]
7.5
Dynamic information
8.5
8.5
6 7
7.5
● Compatible for indoor and outdoor use
● Excellent oil resistance
Chainflex Control Cable
Chainflex Control Cable
UV resistance High
Oil resistance
Silicone-free
Halogen-free Following DIN EN 60754
PTFE-free The design of these products does not contain PTFE
REACH In accordance with regulation (EC) No. 1907/2006 (REACH)
Lead-free Following 2011/65/EC (RoHS-II)
CE Following 2014/35/EU
Clean room
Conductor no
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 4/4
TRE.UL.XX.XX
Green
Colours according to DIN ISO 47100
Colour code in accordance with DIN 47100
Colours according to DIN ISO 47100 Conductor no
19
20
21
22
23
24
White-pink
Pink-brown
White
Brown
36
White-grey
Grey-brown
34
35 Green-black
Yellow-black
Green-red
Grey
Pink
Blue
Red
Black
White-yellow
25
26
27
Yellow-red
Brown-green 32
Yellow-brown
Yellow-blue
33
Grey-green
Yellow
White-blue
Brown-blue
White-red
Brown-red
28
29
30
31
Violet
Grey-pink
Red-blue
White-green
Brown-black
Yellow-grey
Pink-green
Yellow-pink
Green-blue
White-black
Oil-resistant (following DIN EN 60811-404) (following VDMA 24568with
Plantocut 8 S-MB tested by DEA),Class4
According to ISO- tested by IPA Class 1 according to
DIN EN ISO 14644-1
●For heaviest duty applications ●TPE outer jacket ●Oil and bio-oil resistant ●PVC-free
●Low-temperature-flexible ●Hydrolysis and microbe-resistant
Properties and approvals
Free from silicone which can affect paint adhesion
(following PV 3.10.7 – status 1992)
Chainflex Control Cable
Chainflex Control Cable
Certification
Number of cores 4C 6C 12C 18C
Core design
Conductor
Insulation
Insulation clor
Core structure
Cfrip
Filer
Inner jacket
Overall shield
Jacket
Jacket clor
E145335 AWM STYLE 20549 XXAWG 80℃ 300V AWM I A/B 80℃ 300V FT2 DATAFIELD
In the XXAWG, XX can be 24, or 26.
Marking clor
Ambient temperature
Rated voltage
Dielectric strength
Spark Test
Insulation resistance
Flame test
Nominal cross-sectional
area
Outer diameter(d)
max
Copper index Weight Max.conductor
resistanceat 20℃
Max.current
rating at 30℃
mm² mm kg/km kg/km Ω/km A
TRU.01.04 4x0.14 (26AWG) 6.5 18 49 138 2.5
TRU.01.08 8x0.14 (26AWG) 7.5 31 66 138 2.5
TRU.01.12 12x0.14 (26AWG) 9.5 51 102 138 2.5
TRU.01.18 18x0.14 (26AWG) 10.5 56 135 138 2.5
TRU.02.04 4x0.25 (24AWG) 7.0 25 59 79 5
TRU.02.08 8x0.25 (24AWG) 8.0 43 84 79 5
TRU.02.18 18x0.25 (24AWG) 12.0 100 173 79 5
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 1/3
PVC mixture adapted to suit the requirements in e-chains®
Extremely bending-resistant braiding made of tinned copper wires. Coverage linear approx. 70%, optical approx. 90%
3.0 KV Insulation/Jacket
≥10MΩ
VW-1/FT1
Anthracite grey (similar to RAL 7016)
●For heaviest duty applications ●PUR outer jacket ●Oil-resistant and coolant-resistant ●Shielded
●Notch-resistant ●Hydrolysis and microbe-resistant
White
-40℃ ~ +80℃
300V
No cracking (AC 2000V/1Minute)
TRU.XX.XX
Specifications
Cross Section
Stranded conductor in especially bending-resistant version
consisting of bare copper wires
Colour code in accordance with DIN 47100
Tensile stress-resistant centre element
E145335: UL21296/UL21297
8C
Mechanically high-quality TPE mixture.
Cores wound in a layer with especially short pitch length
Part Number
Part No
Marking
Low-adhesion, halogen-free, highly abrasion resistant PUR mixture
Tear strip for faster cable stripping
c
Chainflex Control Cable
Chainflex Control Cable
linear minimum 5 x OD
Bend radius Flexible minimum 4 x OD
Fixed minimum 3 x OD
linear -20 °C up to +80°C
Temperature Flexible -40°C up to+80°C(following DIN EN 60811-504)
Fixed -50°C up to +80 °C (following DIN EN 50305)
unsupported 10 m/s
Gliding 6 m/s
Travel distance
Double strokes 5million
Temperature,from/to [°C] R min.
[x d]
-20 ~ -10 6.8
-10 ~ +70 5
+70 ~ +80 6.8
Test bend radius approx. 28 - 75 mm
Test travel S approx. 1 - 15 m
Test duration minimum 3 - 5 million double strokes
Test speed approx. 0.5 - 2 m / s
Test acceleration approx. 0.5 - 1.5 m /s²
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 2/3
7.5
Unsupported travels and up to 100m for gliding
applications, Class 5
Dynamic information
●For heaviest duty applications ●PUR outer jacket ●Oil-resistant and coolant-resistant ●Shielded
●Notch-resistant ●Hydrolysis and microbe-resistant
TRU.XX.XX
8.5
8.5
6.8 7.5
7.5
7.5million
Typical lab test setup for this cable series
● Suitable for short,very fast applications
Application
● Suitable for small space applications
● Excellent oil resistance
● Compatible for indoor and outdoor use
V max
Guaranteed service life according to guarantee conditions
10million
R min.
[x d] R min.
[x d] Chainflex Control Cable
Chainflex Control Cable
UV resistance High
Oil resistance
Silicone-free
Offshore MUD-resistant following NEK 606 - status 2016
PTFE-free The design of these products does not contain PTFE
REACH In accordance with regulation (EC) No. 1907/2006 (REACH)
Lead-free Following 2011/65/EC (RoHS-II)
CE Following 2014/35/EU
Clean room
Conductor no
1
2
3
4
5
6
7
8
9
10
11
12
13
14
15
16
17
18
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com 3/3
Brown-red
28
29
30
31
32
Violet
Grey-pink
Red-blue
White-green
Brown-green
27
Colours according to DIN ISO 47100
19
Green-red
Grey
Pink
Blue
Red
Black
White-yellow
Grey-green
Yellow-grey
Pink-green
Yellow-pink
Green-blue
Free from silicone which can affect paint adhesion
(following PV 3.10.7 – status 1992)
Yellow
White-blue
Brown-blue
White-red
22
23
24
Brown
Oil-resistant (following DIN EN 50363-10-2), Class 3
According to ISO- tested by IPA Class 1 according to
DIN EN ISO 14644-1
Yellow-black
White-black
●For heaviest duty applications ●PUR outer jacket ●Oil-resistant and coolant-resistant ●Shielded
●Notch-resistant ●Hydrolysis and microbe-resistant
Properties and approvals
Colour code in accordance with DIN 47100
Colours according to DIN ISO 47100 Conductor no
36
White-grey
Yellow-red
Grey-brown
25
26
Pink-brown
33
34
35
20
Green 21
Yellow-brown
Brown-black
Green-black
Yellow-blue
White-pink
TRU.XX.XX
White
Chainflex Control Cable
3-pole 4-pole
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
3P
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M8 Connector
Connector
M8, Female, A-cod.
Specifications
M8
3P 4P
A
3
Female
M8 x 1
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
50 V
60 V
4 A
Device Protection | Electrical
Conformity
1,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
FKM
Environmental Characteristics | Climatic
-40 °C
105 °C
EN IEC 61076-2-104 (M8)
UL CYJV. E551969
Part Number
XXXXXXXX
XXXXXXXX
2
M8 Connector
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
5P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
IP65, IP66K,IP67 M8 Connector
Connector
M8, Female, B-cod., 5-pole
Specifications
M8
B
Female
M8 x 1
PUR
Brass
Gold plated
5P
Zinc die-casting
Electrical Data | Supply
50 V
60 V
4 A
Device Protection | Electrical
3
EN IEC 61076-2-104 (M8)
UL CYJV. E551969
Part Number
XXXXXXXX
Nickeled
FKM
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
1,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
2
M8 Connector
3-pole 4-pole
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min.
Operating temperature max.
Product standard
Certification
3P
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
IP65, IP66K,IP67 M8 Connector
Connector
M8, Male, A-cod.
Specifications
M8
3P 4P
A
Male
M8 x 1
PUR
Brass
Gold plated
Zinc die-casting
Electrical Data | Supply
50 V
60 V
4 A
Device Protection | Electrical
3
1,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Nickeled
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
EN IEC 61076-2-104 (M8)
UL CYJV. E551969
Part Number
XXXXXXXX
XXXXXXXX
2
M8 Connector
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
50 V M8 Connector
Connector
M8, Female, D-cod., 4-pole
Specifications
M8
4P
D
Female
M8 x 1
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
FKM
60 V
4 A
Device Protection | Electrical
3
1,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
Part Number
TPL000-0002-50019
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
EN IEC 61076-2-104 (M8)
UL CYJV. E551969
2
M8 Connector
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min.
Operating temperature max.
Product standard
Certification
5P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M8 Connector
Connector
M8, Male, B-cod., 5-pole
Specifications
M8
5P
B
Male
M8 x 1
I
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
50 V
60 V
4 A
Device Protection | Electrical
3
1,5 Kv
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
Part Number
XXXXXXXX
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
EN IEC 61076-2-104 (M8)
UL CYJV. E551969
2
M8 Connector
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min.
Operating temperature max.
Product standard
Certification
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M8 Connector
Connector
M8, Male, D-cod., 4-pole
Specifications
M8
4P
D
Male
M8 x 1
I
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
50 V
60 V
4 A
Device Protection | Electrical
3
1,5 Kv
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
Part Number
XXXXXXXX
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
EN IEC 61076-2-104 (M8)
UL CYJV. E551969
2
M8 Connector
4-pole 5-pole
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
4P
5P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12
M12 x 1
A
Electrical Data | Supply
Device Protection | Electrical
Zinc die-casting
Nickel plated
Zinc die-casting
FKM
Conformity
Nickeled
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
Environmental Characteristics | Climatic
-40 °C
105 °C
I
Mechanical Data | Material Data
IP65, IP66K,IP67
60 V
60 V
4 A
Part Number
TPL000-0002-50007
TPL000-0002-50017
M12 Connector
Connector
M12, Female, A-cod.
Specifications
Female
PUR
Brass
Gold plated
4P 5P
3
2,5 Kv
2
M12 Connector
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
8P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
IP65, IP66K,IP67 M12 Connector
Connector
M12, Female, A-cod., 8-pole
Specifications
M12
A
Female
M12 x 1
PUR
Brass
Gold plated
Nickel plated
Zinc die-casting
Electrical Data | Supply
30 V
30 V
2 A
Device Protection | Electrical
3
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
Part Number
TPL000-0002-50009
8P
Nickeled
FKM
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
2,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
2
M12 Connector
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
12P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
30 V M12 Connector
Connector
M12, Female, A-cod., 12-pole
Specifications
M12
12P
A
Female
M12 x 1
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
FKM
30 V
1.5 A
Device Protection | Electrical
3
2,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
Part Number
TPL000-0002-50011
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
2
M12 Connector
4-pole 5-pole
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
4P
5P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Connector
Connector
M12, Female, B-cod.
Specifications
M12
4P 5P
B
3
Female
M12 x 1
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
60 V
60 V
4 A
Device Protection | Electrical
Conformity
1,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
FKM
Environmental Characteristics | Climatic
-40 °C
105 °C
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
Part Number
XXXXXXXX
XXXXXXXX
2
M12 Connector
4-pole 5-pole
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
4P
5P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Connector
Connector
M12, Female, D-cod.
Specifications
M12
4P 5P
D
3
Female
M12 x 1
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
60 V
60 V
4 A
Device Protection | Electrical
Conformity
1,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
FKM
Environmental Characteristics | Climatic
-40 °C
105 °C
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
Part Number
TPL000-0002-50003
XXXXXXXX
2
M12 Connector
4-pole 5-pole
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min.
Operating temperature max.
Product standard
Certification
4P
5P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
IP65, IP66K,IP67 M12 Connector
Connector
M12, Male, A-cod.
Specifications
M12
4P 5P
A
Male
M12 x 1
PUR
Brass
Gold plated
Zinc die-casting
Electrical Data | Supply
60 V
60 V
4 A
Device Protection | Electrical
3
2,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Nickeled
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
Part Number
TPL000-0002-50006
TPL000-0002-50016
2
M12 Connector
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min.
Operating temperature max.
Product standard
Certification
8P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Connector
Connector
M12, Male, A-cod., 8-pole
Specifications
M12
8P
A
Male
M12 x 1
I
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
30 V
30 V
2 A
Device Protection | Electrical
3
2,5 Kv
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
Part Number
TPL000-0002-50008
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
2
M12 Connector
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min.
Operating temperature max.
Product standard
Certification
12P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Connector
Connector
M12, Male, A-cod., 12-pole
Specifications
M12
12P
A
Male
M12 x 1
I
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
30 V
30 V
1.5 A
Device Protection | Electrical
3
2,5 Kv
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
Part Number
TPL000-0002-50010
Environmental Characteristics | Climatic
-40 °C
105 °C
Conformity
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
2
M12 Connector
4-pole 5-pole
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
4P
5P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Connector
Connector
M12, Male, B-cod.
Specifications
M12
4P 5P
B
3
Male
M12 x 1
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
60 V
60 V
4 A
Device Protection | Electrical
Conformity
1,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
FKM
Environmental Characteristics | Climatic
-40 °C
105 °C
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
Part Number
XXXXXXXX
XXXXXXXX
2
M12 Connector
4-pole 5-pole
Family construction form
No. of poles
Pin layout(Female)
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC
60529)
Operating voltage AC max.
Operating voltage DC max.
Current operating per
contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min.
Operating temperature max.
Product standard
Certification
4P
5P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Connector
Connector
M12, Male, D-cod.
Specifications
M12
4P 5P
D
3
Male
M12 x 1
PUR
Brass
Gold plated
IP65, IP66K,IP67
Electrical Data | Supply
60 V
60 V
4 A
Device Protection | Electrical
Conformity
1,5 Kv
I
Mechanical Data | Material Data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
FKM
Environmental Characteristics | Climatic
-40 °C
105 °C
EN IEC 61076-2-101 (M12)
UL CYJV. E551969
Part Number
TPL000-2002-05152
XXXXXXXX
2
M12 Connector
Family construction form
No. of poles
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Operating voltage AC max
Operating voltage DC max.
Current operating per contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min
Operating temperature max.
Product standard
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
A
Female
M8 x 1
Electrical data | Supply
50 V
60 V
Female cordset
M8 Female 0° A-cod. with cable
Specifications
M8
4
4A
PUR
Brass
Gold plated
IP65, IP66K,IP67
5M (The length can be customized according to customer requirements)
Environmental characteristics | Climatic
-25 °C
85 °C
Conformity
EN IEC 61076-2-104 (M8)
M8 Female cordset
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
FKM
Device protection | Electrical
3
1.5 kV
I
Mechanical data | Material data
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
M8 Female cordset
UL AWM Style
Stranding
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Ingredient freeness wire insulation
Material jacket
Outer-diameter (jacket)
Jacket Color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity max. (wire)
Current load capacity (standard)
Operating temperature (static)
Operating temperature (dynamic)
Operating temperature (drag chain)
Flame resistance
Oil resistance
Chemical resistance
Other resistances
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
Acceleration (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
IEC 60811-404
good
good resistance to gasoline, resistant to hydrolysis, resistant to microbes
5 × Outer diameter
Female cordset
1.25 ± 0.05mm
1 × 4 wires stranded
Brown, black, blue, white
PP
4
Part Number
XXXXXXXX
Black
0.25 mm²(32 × 0.1 mm)
Stranded copper wire, bare
PUR
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
4.5 mm ± 5 %
-25 °C … 80 °C / 90 °C @ 10000 h Operation
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
abrasion-resistant, low adhesion, good machinability, matte
± 180 °/m
35 cycles/min
Installation | Cable
UL20549
3.6 A
10 Mio. @ 25 °C
10 m @ 25 °C | horizontal
79 Ω/km @ 20 °C
300 V
2.5 kV @ 60 s
2.5 kV @ 60 s
to DIN VDE 0298-4
-40 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
10 × Outer diameter
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
M8 Female cordset
3 m/s @ 25 °C
10 m/s² @ 25 °C
2 Mio.
M8 Female cordset
Family construction form
No. of poles
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Operating voltage AC max
Operating voltage DC max.
Current operating per contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min
Operating temperature max.
Product standard
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
Male cordset
M8 Male 0° A-cod. with cable
Zinc die-casting
Electrical data | Supply
50 V
60 V
4A
Device protection | Electrical
3
1.5 kV
I
Mechanical data | Material data
Zinc die-casting
Nickel plated
Nickeled
Environmental characteristics | Climatic
-25 °C
85 °C
IP65, IP66K,IP67
5M (The length can be customized according to customer requirements)
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
Conformity
EN IEC 61076-2-104 (M8)
M8 Male cordset
Specifications
M8
4
A
Male
M8 x 1
PUR
Brass
Gold plated M8 Male cordset
UL AWM Style
Stranding
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Ingredient freeness wire insulation
Material jacket
Outer-diameter (jacket)
Jacket Color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity max. (wire)
Current load capacity (standard)
Operating temperature (static)
Operating temperature (dynamic)
Operating temperature (drag chain)
Flame resistance
Oil resistance
Chemical resistance
Other resistances
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
Acceleration (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
0.25 mm²(32 × 0.1 mm)
Stranded copper wire, bare
Female cordset
1 × 4 wires stranded
Brown, black, blue, white
PP
4
1.25 ± 0.05mm
Part Number
XXXXXXXX
good
good resistance to gasoline, resistant to hydrolysis, resistant to microbes
5 × Outer diameter
2.5 kV @ 60 s
to DIN VDE 0298-4
-40 °C … 80 °C / 90 °C @ 10000 h Operation
25 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
± 180 °/m
35 cycles/min
Installation | Cable
UL20549
3.6 A
10 Mio. @ 25 °C
10 m @ 25 °C | horizontal
10 × Outer diameter
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
IEC 60811-404
abrasion-resistant, low adhesion, good machinability, matte
79 Ω/km @ 20 °C
300 V
2.5 kV @ 60 s
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
PUR
M8 Male cordset
3 m/s @ 25 °C
10 m/s² @ 25 °C
2 Mio.
4.5 mm ± 5 %
Black
M8 Male cordset
Family construction form
No. of poles
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Electrical data | Supply
Operating voltage AC max
Operating voltage DC max.
Current operating per contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min
Operating temperature max.
Product standard
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
-30 °C
85 °C
Conformity
EN IEC 61076-2-101 (M12)
Nickel plated
Zinc die-casting
Nickeled
Specifications
M12
4
A
Female
M12 x 1
5M (The length can be customized according to customer requirements)
3
2,5 kV
I
Mechanical data | Material data
Zinc die-casting
PUR
FKM
Environmental characteristics | Climatic
Brass
Gold plated
4A
Device protection | Electrical
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
250 V
IP65, IP66K,IP67
250 V
M12 Female cordset
Female cordset
M12 Female 0° A-cod. with cable
M12 Female cordset
UL AWM Style
Stranding
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Ingredient freeness wire insulation
Material jacket
Outer-diameter (jacket)
Jacket Color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity max. (wire)
Current load capacity (standard)
Operating temperature (static)
Operating temperature (dynamic)
Operating temperature (drag chain)
Flame resistance
Oil resistance
Chemical resistance
Other resistances
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
Acceleration (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
Part Number
XXXXXXXX
Installation | Cable
10 × Outer diameter
IEC 60811-404
good
good resistance to gasoline, resistant to hydrolysis, resistant to microbes
5 × Outer diameter
2.5 kV @ 60 s
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
abrasion-resistant, low adhesion, good machinability, matte
57Ω /km @ 20 °C
300 V
0.34 mm²(42 × 0.1 mm)
Stranded copper wire, bare
PUR
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
2.5 kV @ 60 s
to DIN VDE 0298-4
-40 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
25 °C … 80 °C / 90 °C @ 10000 h Operation
UL20549
4.8 A
10 Mio. @ 25 °C
10 m @ 25 °C | horizontal
M12 Female cordset
1.25 ± 0.05mm
Female cordset
1 × 4 wires stranded
Brown, black, blue, white
PP
4
4.5 mm ± 5 %
Black
3 m/s @ 25 °C
10 m/s² @ 25 °C
5 Mio.
± 360 °/m
35 cycles/min
M12 Female cordset
Family construction form
No. of poles
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Operating voltage AC max
Operating voltage DC max.
Current operating per contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min
Operating temperature max.
Product standard
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
Brass
5M (The length can be customized according to customer requirements)
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
Electrical data | Supply
250 V
4A
Device protection | Electrical
3
2,5 kV
I
Mechanical data | Material data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
Environmental characteristics | Climatic
-30 °C
85 °C
Conformity
250 V
Specifications
M12
4
A
Male
M12 x 1
Gold plated
IP65, IP66K,IP67
PUR
EN IEC 61076-2-101 (M12)
M12 Male cordset
Male cordset
M12 Male 0° A-cod. with cable
M12 Male cordset
UL AWM Style
Stranding
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Ingredient freeness wire insulation
Material jacket
Outer-diameter (jacket)
Jacket Color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity max. (wire)
Current load capacity (standard)
Operating temperature (static)
Operating temperature (dynamic)
Operating temperature (drag chain)
Flame resistance
Oil resistance
Chemical resistance
Other resistances
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
Acceleration (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
Part Number
35 cycles/min
± 360 °/m
XXXXXXXX
5 × Outer diameter
2.5 kV @ 60 s
to DIN VDE 0298-4
-40 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
10 × Outer diameter
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
IEC 60811-404
good
good resistance to gasoline, resistant to hydrolysis, resistant to microbes
Installation | Cable
UL20549
4.8 A
10 Mio. @ 25 °C
Female cordset
PUR
1 × 4 wires stranded
Brown, black, blue, white
PP
4
1.25 ± 0.05mm
0.34 mm²(42 × 0.1 mm)
Stranded copper wire, bare
M12 Female cordset
10 m @ 25 °C | horizontal
3 m/s @ 25 °C
10 m/s² @ 25 °C
5 Mio.
abrasion-resistant, low adhesion, good machinability, matte
57Ω /km @ 20 °C
300 V
2.5 kV @ 60 s
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
4.5 mm ± 5 %
Black
M12 Male cordset
Family construction form
No. of poles
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Operating voltage AC max
Operating voltage DC max.
Current operating per contact max.
Pollution degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min
Operating temperature max.
Product standard
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M8 Female cordset 90°
Electrical data | Supply
Female cordset
M8 Female 90° A-cod. with cable
Specifications
M8
3
A
Female
M8 x 1
PUR
Copper alloy
Gold plated
IP65, IP66K, IP67
5M (The length can be customized according to customer requirements)
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
Nickeled
50 V
60 V
4A
Device protection | Electrical
3
1.5 kV
I
Mechanical data | Material data
Zinc die-casting
Nickel plated
Zinc die-casting
FKM
Environmental characteristics | Climatic
-25 °C
85 °C
Conformity
EN/EC 61076-2-101 (M8)
M8 Female cordset 90°
UL AWM Style
Stranding
Filler
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Amount strands (wire)
Diameter of single wires
Material properties wire insulation
Ingredient freeness wire insulation
Outer-diameter (jacket)
Material jacket
Jacket color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity (standard)
Current load capacity max. (wire)
Operating temperature (static)
Operating temperature (dynamic)
Operating temperature (drag chain)
Flame resistance
Oil resistance
Chemical resistance
Other resistances
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
Acceleration (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
3P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M8 Female cordset 90°
Brown, black, blue
PP
3
1.25 ± 0.05mm
Female cordset
Installation | Cable
1 x 3 Wires stranded
N/A
20549 / 10493
PUR
0.25 mm²
Stranded copper wire, bare
32
0.1 mm
Good machinability
Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
4.1mm ± 5 %
Black / RAL 9005
Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Abrasion-resistant, low adhesion, good machinability, matte
79Ω /km @ 20 °C
± 180 °/m
-25 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
-40 °C … 80 °C / 90 °C @ 10000 h Operation
IEC 60811-404
Good
Good resistance to gasoline, resistant to hydrolysis, resistant to microbe
5 × Outer diameter
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
300 V
2.5 kV @ 60 s
2.5 kV @ 60 s
to DIN VDE 0298-4
4.5 A
35 Cycles/min
Part number
XXXXXXXX
10 × Outer diameter
10 Mio. @ 25°C
10 m@25°C | horizontal
3 m/s @ 25 °C
10 m/s² @ 25 °C
2 Mio.
M8 Female cordset 90°
Family construction form
No. of poles
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Operating voltage AC max
Operating voltage DC max.
Current operating per contact max.
Pollution degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min
Operating temperature max.
Product standard
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
A
Male
M8 x 1
PUR M8 Male cordset 90°
Male cordset
M8 Male 90° A-cod. with cable
Specifications
M8
3
1.5 kV
Copper alloy
Nickel plated
IP65, IP66K, IP67
5M (The length can be customized according to customer requirements)
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
Electrical data | Supply
50 V
60 V
4A
Device protection | Electrical
3
EN/EC 61076-2-104 (M8)
I
Mechanical data | Material data
Brass
Nickel plated
Zinc die-casting
Nickeled
N/A
Environmental characteristics | Climatic
-25 °C
85 °C
Conformity
M8 male cordset 90°
UL AWM Style
Stranding
Filler
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Amount strands (wire)
Diameter of single wires
Material properties wire insulation
Ingredient freeness wire insulation
Outer-diameter (jacket)
Material jacket
Jacket color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity (standard)
Current load capacity max. (wire)
Operating temperature (static)
Operating temperature (dynamic)
Operating temperature (drag chain)
Flame resistance
Oil resistance
Chemical resistance
Other resistances
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
Acceleration (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
3P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M8 Male cordset 90°
± 180 °/m
35 Cycles/min
Part number
XXXXXXXX
10 Mio. @ 25°C
10 m@25°C | horizontal
3 m/s @ 25 °C
10 m/s² @ 25 °C
2 Mio.
IEC 60811-404
Good
Good resistance to gasoline, resistant to hydrolysis, resistant to microbes
5 × Outer diameter
10 × Outer diameter
0.1 mm
Male cordset
Installation | Cable
1 x 3 Wires stranded
N/A
32
Good machinability
Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
4.1mm ± 5 %
Brown, black, blue
PP
3
1.25 ± 0.05mm
0.25 mm² (32x0.1mm)
PUR
-25 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
20549 / 10493
300 V
2.5 kV @ 60 s
2.5 kV @ 60 s
to DIN VDE 0298-4
4.5 A
-40 °C … 80 °C / 90 °C @ 10000 h Operation
Black / RAL 9005
Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Abrasion-resistant, low adhesion, good machinability, matte
79Ω /km @ 20 °C
Stranded copper wire, bare
M8 male cordset 90°
Family construction form
No. of poles
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Operating voltage AC max
Operating voltage DC max.
Current operating per contact max.
Pollution degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min
Operating temperature max.
Product standard
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Female cordset 90°
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
4
Environmental characteristics | Climatic
-30 °C
A
Female
85 °C
Mechanical data | Material data
Zinc die-casting
Nickel plated
Zinc die-casting
Specifications
PUR
M12 x 1
Gold plated
IP65, IP66K, IP67
5M (The length can be customized according to customer requirements)
2.5 kV
I
FKM
M12
Copper alloy
Nickeled
Device protection | Electrical
3
Conformity
EN IEC 61076-2-101 (M12)
Female cordset
M12 Female 90° A-cod. with cable
Electrical data | Supply
250 V
250 V
4A
M12 Female cordset 90°
UL AWM Style
Stranding
Filler
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Material properties wire insulation
Ingredient freeness wire insulation
Outer-diameter (jacket)
Material jacket
Jacket color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity (standard)
Current load capacity max. (wire)
Operating temperature min. (static)
Operating temperature max. (fixed)
Operating temperature min. (dynamic)
Operating temperature max. (dynamic)
Flame resistance
Oil resistance
Chemical resistance
Gasoline resistance
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Female cordset 90°
2 Mio.
± 180 °/m
35 Cycles/min
Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Abrasion-resistant, low adhesion, good machinability, matte
4
Female cordset
Brown, black, blue, white
PUR
Part number
XXXXXXXX
to DIN VDE 0298-4
4.8 A
-40 °C
80°C/90°C@10000 h Operation
57Ω /km @ 20 °C
20549 / 10493
Black
Good machinability
Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
4.5 mm ± 5 %
1.25 ± 0.05mm
-25 °C
80°C/90°C@10000 h Operation
Good, application-related testing | DIN EN 60811-404
UL 1581 $ 1090 | IEC 60332-2-2 | UL 1581 $ 1100 FT2
300 V
2.5 kV @ 60 s
2.5 kV @ 60 s
Good, application-related testing
Good, application-related testing
5 × Outer diameter
10 × Outer diameter
10 Mio. @ 25°C
10 m@25°C | horizontal
3 m/s @ 25 °C
Installation | Cable
4 Wires stranded
Stranded copper wire, bare
PP
0.34 mm² (42x0.1mm)
N/A
M12 Female cordset 90°
Family construction form
No. of poles
Coding
Gender
Threaded hole
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Operating voltage AC max
Operating voltage DC max.
Current operating per contact max.
Pollution degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Operating temperature min
Operating temperature max.
Product standard
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Male cordset 90°
4A
Device protection | Electrical
3
EN IEC 61076-2-101 (M12)
I
Mechanical data | Material data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
Environmental characteristics | Climatic
-30 °C
5M (The length can be customized according to customer requirements)
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
Electrical data | Supply
250 V
250 V
Male cordset
M12 Male 90° A-cod. with cable
Specifications
M12
4
A
Male
M12 x 1
PUR
2.5 kV
Copper alloy
Gold plated
IP65, IP66K, IP67
85 °C
Conformity
M12 Male cordset 90°
UL AWM Style
Stranding
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Material properties wire insulation
Ingredient freeness wire insulation
Outer-diameter (jacket)
Material jacket
Jacket color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity (standard)
Current load capacity max. (wire)
Operating temperature (static)
Operating temperature (dynamic)
Operating temperature (drag chain)
Flame resistance
Oil resistance
Chemical resistance
Other resistances
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
M12 Male cordset 90°
Part number
XXXXXXXX
10 m@25°C | horizontal
3 m/s @ 25 °C
5 Mio.
± 360 °/m
35 Cycles/min
Good
Good resistance to gasoline, resistant to hydrolysis, resistant to microbes
5 × Outer diameter
10 × Outer diameter
10 Mio. @ 25°C
-25 °C … 80 °C / 90 °C @ 10000 h Operation
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
IEC 60811-404
-40 °C … 80 °C / 90 °C @ 10000 h Operation
Black / RAL 9005
Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
Abrasion-resistant, low adhesion, good machinability, matte
57Ω /km @ 20 °C
300 V
2.5 kV @ 60 s
2.5 kV @ 60 s
to DIN VDE 0298-4
4.8 A
-25 °C … 80 °C / 90 °C @ 10000 h Operation
Brown, black, blue, white
PP
4
1.25 ± 0.05mm
PUR
0.34 mm² (42x0.1mm)
Stranded copper wire, bare
Good machinability
Lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
4.5 mm ± 5 %
Male cordset
Installation | Cable
4 Wires stranded
20549 / 10493
M12 Male cordset 90°
Family construction form
No. of poles
Coding
Gender
Threaded hole
Cable outlet
Material
Material contact
Coating contact
Degree of protection (EN IEC 60529)
Cable length
Cable length tolerance
Operating voltage DC
Operating voltage DC min.
Operating voltage DC max.
Current operating per contact max.
Pollution Degree
Rated surge voltage
Material group (IEC 60664-1)
Screw connection
Coating of fitting
Locking material
Coating locking
Gasket
Operating temperature min
Operating temperature max.
Product standard
Certification
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
Angled
UL CYJV. E551969
Electrical data | Supply
24 V
Environmental characteristics | Climatic
-30 °C
85 °C
Conformity
EN IEC 61076-2-101 (M12)
Mechanical data | Material data
Zinc die-casting
Nickel plated
Zinc die-casting
Nickeled
FKM
Displays / operating elements
Display Switching status 2 x LED, yellow
Power 1 x LED, green
I
Brass
Gold plated
IP65, IP66K,IP67
5M (The length can be customized according to customer requirements)
0M<L≤0.5M: +0.03M,0.5M<L≤1M: +0.05M,
1M<L≤3M: +0.1M,3M<L: ±1.5%.
18 V
30 V
4A
Device protection | Electrical
3
0.8 kV
A
Female
M12 x 1
PUR M12 Female cordset 90° with LED
Female cordset
M12 Female 90° A-cod. with cable LED
Specifications
M12
4
M12 Female cordset 90°with LED
Installation | Cable
UL AWM Style
Stranding
Wire arrangement
Material wire insulation
Amount wires
Outer diameter insulation
Conductor crosssection (wire)
Material conductor wire
Ingredient freeness wire insulation
Material jacket
Outer-diameter (jacket)
Jacket Color
Freedom from ingredients (jacket)
Material property (jacket)
Conductor resistance (wire)
Nominal voltage max.
Withstand voltage (wire - wire)
Withstand voltage (wire - jacket)
Current load capacity (standard)
Operating temperature (static)
Operating temperature (dynamic)
Operating temperature (drag chain)
Flame resistance
Oil resistance
Chemical resistance
Other resistances
Bending radius (fixed)
Bending radius (dynamic)
No. of bending cycles (C-track)
Traversing distance (C-track)
Travel speed (C-track)
Acceleration (C-track)
No. of torsion cycles
Torsion stress
Torsion speed
4P
Datafield Intelligent Electronics (Dongguan) Co., Ltd www.datafield-hk.com
Connection
± 360 °/m
35 cycles/min
UL20549
1 × 4 wires stranded
Brown, black, blue, white
PP
4
good resistance to gasoline, resistant to hydrolysis, resistant to microbes
5 × Outer diameter
2.5 kV @ 60 s
to DIN VDE 0298-4
-40 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
-25 °C … 80 °C / 90 °C @ 10000 h Operation
abrasion-resistant, low adhesion, good machinability, matte
4.5mm ± 5 %
5 Mio.
Part Number
XXXXXXXX
10 × Outer diameter
10 Mio. @ 25 °C
10 m @ 25 °C | horizontal
3 m/s @ 25 °C
10 m/s² @ 25 °C
UL 1581 § 1090, CSA FT2, IEC 60332-2-2
IEC 60811-404
good
M12 Female cordset 90° with LED
57Ω /km @ 20 °C
300 V
2.5 kV @ 60 s
1.25 ± 0.05 mm
Black
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
lead-free, cadmium-free, CFC-free, halogen-free, silicone-free
PUR
0.34 mm²(42x0.1mm)
Stranded copper wire, bare
Female cordset
M12 Female cordset 90° with LED