The professional manufacturer & solution provider of ELEVATOR & ESCALATOR
ABOUT JOYLIVE
Specialization makes us doing better
Joylive Elevator Co., Ltd. (Previously called Suzhou Great Elevator) is the China premier solution provider of elevators, escalators and related services. It was established in Kunshan (60km to Shanghai), Suzhou city in 2002 and went to public in September 2015. With 2 manufacturing centers of 105,000 square meters and more than 700 employees, it can product 18, 000 units elevator and escalator per year. The products include Joycity – Business Passenger Elevators, Joylife –Residential Passenger Elevators, Joyvilla - Home Elevators, Joylogi – Freight Elevators, Joywalk - Escalators, and Autowalks.
The company focuses on creating a nationwide marketing and service network system integrating sales, engineering, and services. At the same time, it actively explores international market. After continuous development, Joylive Elevator'ssales and service network have covered more than 50 countriesincludingRussia, Middle-Asia, South-America, NewZealand, Australian, Southeast Asia, Middle East, and Africa etc.
Joylive insists on quality and brand building and has maintained rapid growth for many years. It is determined to develop into a high-end manufacturing and service company. We willcontinue to offer the devised products with high quality to the customers, and endeavor to be the most competitive elevator enterprises in the world and the first elevator brand choice of customers.
CE EAC
CuropeanAll ance CE Cerlificale
Customs Union TR CU-TR CerLificale
Our offering Smart and secure access solutions for variety customers'needs
Residential Passenger Elevator
Simple and practical for smaller residential buildings. Optimal solution that meets the essential requirements in terms of performance, design and other options, low costs and greater convenience.
Panoramic Elevator
High-quality system solutions made from glass - for a wide range of everyday and office applications. energy saving traction elevator, available as Machine Room Less or Mini Machine Room configuration.
Commercial Passenger Elevator
For commercial and high- end residential buildings allowing flexible combination of system layout, which makes it suitable for special applications like hotels, shopping centers and public buildings.
Freight Elevator
A heavy-duty elevator for buildings with demanding requirements for service andgoodstransport. Solid set of standard features specially designed togoods transportation requirements.
Hospital Elevator
Safe, smooth and reliable elevator designed especially for hospitals, with a solid set of features for optimum performance in the highly demanding environment of patient transportation.
Home Elevator
Provide directional villa elevator custom service for top luxury market. Offers a certain design and dimensioning flexibility, providing green mobility, smart operations and space efficiency.
Joylive's product portfolio is set up to provide an optimal mobility solution for modern buildings and urbanenvironmentssuch as residential properties, offices, airports, hospitals, hotels, villas, stadiums and malls & retail projects. By around 700 experienced and committed employees, we now deliver even more comprehensive and innovative products, solutions and services for customers around the world.
Escalator & moving walk
Meets the specific requirements of commercial buildings and public transport applications; with various configuration packages, dependable performance and passenger safety.
Dumb Waiter
Suitable for big and small restaurant to transport food and goods; High quality materials, small space needed with compact structure.
Vehicle Elevator
The powerful and high performance vehicle elevator solution is ideal for demandingvertical freight transportation tasks in supermarkets, shopping malls and private house.
Modernization and Upgrading
Boost your elevator's reliability, ecoefficiency, comfort, and appearance - and bring it in line with the latestsafety and accessibility standards — with our modernization solutions for all needs and budgets.
Hydraulic Elevator
Tailor-made services and customized solution, Safe and reliable with electric valves, adjustablespeeds. Not necessary to make major works. Possibility of using organic fluid.
Global reach, local focus Explore our references projects
Domestic Projects
Joylive is providing landmark buildings around the world with its best products and is maintaining them in top condition. Whether installed in a small two-story commercial building or in a skyscraper in a major city, Joylive elevator and escalator, modernization, industry leading destination control and maintenance solutions are unsurpassed.
Overseas Projects
JOYClOUd ELEVATOR IoT PLATFORM
The world is changing more rapidly than ever before, thus bringing about new ways ofdoing things.With new endeavors come new obstacles that require modern solutions. Doing more with less has set the road for Elevator loT (Internet of Things). We provide cutting-edge technology to address all of our client's needs, from automation to tracking. We work beyond the conventional theories to deliver various services and solutions using loT. To every potential problem, we can offer a viable and swift solution. Our team has the ability to gather the specifications, develop a solution and immediately deliver results. Whatever your vertical transportation loT, elevator loT or escalator loT you want to full; The Elevator Consultants has the technical expertise to accommodate your every need.Our team consists of development experts with domain expertise ready to work with you on jobs big and small. Call today to discuss how The Elevator Consultants can work with you to provide modern and economical vertical transportation solutions.
ELEVATOR IoT PLATFORM
Providing digital services for elevator running
Dynamic Diagnosis
By dynamic monitoring of key components, upon detection of any abnormal or near the end of service-life component, early warning will be issued for elimination of the potential risk.
Online installation
From manufacturing of the elevator to its delivery and client ‘s use, the whole installation process is fully monitored.
On-the-grid Rescue
When one unpredicted failure occurs, network positioningsystem will be Instantly prompted, and then, the monitoring center actively dispatches professional engineers to perform the repair.
Remote monitoring
Remote data collection, monitoring, efficient management and control of real-time information.
Online Maintenance
Including automatically generated elevator's specific well functioning records and maintenance diagnostic reports, preset maintenance time, real-time monitoring, maintenance feedback and maintenance progress.
Interactive system
Joycloud 4.0 provides even more innovative and digital services to elevator and includes the experience of multimedia interaction between smart phone and elevator.
Joycloud Androld
Joycloud los
Innovative technology & Safety assurance
Intelligent integrated control driver with accurate calculation of position information, to make elevator leveling more stable, accurately and effectively improve operating efficiency and riding comfort.
Permanent magnet motor, high efficiency, large rotating torque, low energy consumption; highly comfortable with full closed loop control of torque, position and speed.
Various shock absorption measures to reduce vibration conduction. Configured with sound insulation, noise reduction measures to enhance ride comfort and user experience.
Standby power consumption is less than 50W, which reduces the standby power consumption by 50%.
Active door lock to prevent safety problems such as door slamming or forcible opening.
Cabin design
>Wide car to give passenger more feeling of comfortable.
> Full height integrated COP, high-end and elegant design. (Standard)
G5159
Ceiling (G1036) : Mirror St./St., LED Lighting
Car wall : Frosted St./St., mirror St./St., mirror etch St./St.
COP (G2116) : Hairline St./St.
Handrail (G6001) : Hairline St./St.
Floor (FT-05): Marble
H5101
Ceiling (G1038) : Painted steel, Acrylic plate, LED lighting
Car wall : Painted steel,
COP (G2113) : Hairline St./St.
Handrail (G6001) : Hairline St./St.
Floor (G3124): PVC
H5102
Ceiling : Hairline St./St., Acrylic plate, LED lighting
Car wall : Hairline St./St., mirror St./St., mirror etch St./St.
COP (G2113) : Hairline St./St.
Handrail (G6003) : Flat type hairline St/St. Floor (G3315) : Marble
H5112
Ceiling(G1097) : Mirror St./St., LED lighting Car wall: Hairline St./St., mirror St./St. COP(G2116) : Mirror St./St. Handrail (G6003) : Flat type hairline St/St. Floor (G3364) : Marble
H5109
Ceiling (G1062) : Mirror St./St., Acrylic plate, LED Lighting
Car wall : Hairline St./St., mirrorSt./St., mirror etch St./St.
COP (G2116) : Hairline St./St.
Handrail (G6001) : Hairline St./St.
Floor : Marble Ceiling (G1062) : Titanium golden mirror St./St., Acrylic plate, LED Lighting
Car wall : Titanium golden hairline St./St., titanium golden mirror St./St., titanium golden mirror etch St./St.
COP (G2116) : Titanium golden hairline St./St. Handrail (G6001) : Titanium golden hairline St./St. Floor (FT-03) : Marble
Ceiling (G1008) : Hairline St./St., Acrylic Plate, LED Lighting Car wall : Hairline St./St. COP (G2116) : Hairline St./St. Handrail (G6001) : HairlineSt./St. Floor (G3308) : Marble
Ceiling (G1090) : Hairline St./St., Acrylic Plate,LED Lighting Car wall : Decoration steel panel, mirror St./St. COP (G2113) : Hairline St./St. Handrail (G6001) : HairlineSt./St. Floor (G3121) : PVC
Ceiling (G1010): Mirror St./St., Acrylic Plate, LED Lighting Car wall : Hairline St./St. COP (G2116) : Hairline St./St. Handrail (G6001) : HairlineSt./St. Floor (FT-03) : Marble
Ceiling (G1092) : Rose golden mirror St./St., Acrylic plate, LED lighting Car wall : Rose golden mirror St./St., rose golden frosted St./St., marble COP(G2116) : Mirror St./St. Handrail (G6001) : Rose golden mirror St./St. Floor (G3353) : Marble
Ceiling (G1017) : Titanium golden mirror St./St., Acrylic plate, LED Lighting Car wall : Titanium golden hairline St./St., mirror St./St., titanium golden mirror etch St./St. COP (G2116) : Titanium golden hairline St./St. Handrail (G6001) : Titanium golden hairline St./St. Floor (G3315) : Marble
Ceiling (G1008) : Titanium golden mirror St./St., Acrylic plate, LED Lighting Car wall : Titanium golden hairline St./St., mirror St./St., titanium golden mirror etch St./St. COP (G2116) : Mirror St./St. Handrail (G6001) : Hairline St./St. Floor(G3313) : Marble
Ceiling (G1093) : Soft membrane, LED Lighting Car wall : Decoration steel panel, mirror St./St.,hairlineSt./St. COP (G2116) : Mirror St./St. Handrail (G6001) : Hairline St./St. Floor (G3363) : Marble
Ceiling (G1089) : Hairline St./St., LED Lighting Car wall : Decoration steel panel, mirror St./St., hairline St./St. COP (G2113) : Hairline St./St. Handrail (G6001) : Hairline St./St. Floor (G3121) : PVC
Ceiling (G1092) : Mirror St./St., LED Lighting Car wall : Hairline St./St., glass COP (G2116) : Hairline St./St. Handrail (G6001) : Hairline St./St. Floor (G3353) : Marble
Ceiling (G1100) : Black titanium mirror St./St., LED Lighting
Car wall : Black titanium mirror St./St., wood, glass
COP (G2116) : Black titanium mirror St./St.
Handrail (G6001) : Black titanium hairline St./St. Floor(G3364) : Marble
Ceiling (G1092) : Bronze color mirror St./St., Acrylic LED lighting Car wall : Bronze color hairline St./St., bronze color mirror St./St., decoration steel panel COP (G2116) : Bronze color hairline St./St. Handrail (G6001) : Bronze color hairline St./St. Floor (G3364) : Marble
H5103
Ceiling (G1011) : Mirror St./St., Acrylic LED lighting
Car wall : Mirror St./St., mirror etch St./St. COP (G2116) : Mirror St./St.
Handrail (G6001) : Flat type mirror St./St. Floor (FT-06) : Marble Ceiling (G1011) : Mirror St./St., Acrylic LED lighting
Car wall : Mirror St./St., mirror etch St./St. COP (G2116) : Mirror St./St.
Handrail(G6001) : Flat type mirror St./St. Floor (FT-06) : Marble Ceiling (G1005) : Mirror St./St., Acrylic LED lighting
Car wall : Black titanium mirror St./St., frosted St./St.
COP (G2116) : Black titanium mirror St./St. Floor (FT-03) : Marble Ceiling (G1065): Mirror St./St., Acrylic LED lighting
Car wall : Decoration steel panel, mirror St./St. COP (G2116) : Mirror St./St.
Handrail (G6001) : Mirror St./St.
Floor (G3337) : Marble
H5104
Ceiling (G1048) : Mirror St./St., Acrylic LED lighting
Car wall : Decoration steel panel, mirror St./St. COP (G2116) : Mirror St./St.
Handrail (G6001) : Mirror St./St.
Floor (G3313) : Marble
H5107
Ceiling (G1010) : Mirror St./St., Acrylic LED lighting
Car wall : Titanium hairline St./St., mirror St./ St.,titanium mirror etch St./St. COP (G2116) : Titanium hairline St./St. Handrail (G6001) : Titanium hairline St./St. Floor (G3315): Marble
H5105
Ceiling : Mirror St./St., Acrylic LED lighting Car wall : Mirror St./St., mirror etch St./St. COP (G2116) : Mirror St./St.
Handrail : Wood
Floor : Marble
H5108
Ceiling (G1010): Mirror St./St., Acrylic LED lighting
Car wall : Bronze color hairline St./St., bronze color mirror St./St., bronze color mirror etch St./St. COP (G2116) : Bronze color hairline St./St. Handrail (G6001) : Titanium hairline St./St. Floor (FT–03) : Marble
COP Installation Position
COP & HOP
Standard
Split embedded
G2209 Embedded
G2116 Integrated
G2150 Integrated
HOP
Integrated type
G2249 Wall-hanging
Separated type
Handicapped COP
G2122 Embedded
G2306
G2310
COP Indicator
Standard
G2304-H
Blue segmented LCD
Black segmented LCD
Blue segmented LCD
Optional
Dot matrix display
Multi-media LCD
Buttons
G2413-M
Optional
Optional
HOP Indicator
G2307
Black segmented LCD
Optional
G2309
Blue segmented LCD
Multi-media LCD
Hall Lantern
Ceiling design
Hairline St./St., mirror St./St., LED Lighting
G1099 Hairline St./St., LED Lighting
G1090(One-piece) Hairline St./St., Acrylic Plate
Car wall
Stainless Steel
Etching Pattern
G4211
G4213
Decoration panel
Round type hairline St./St.
Flat type hairline St./St.
Floor
PVC
G3109
Marble
G3315
FT-06
Landing door design
| Model/Type | Series | DESCRIPTION +SEGMENT | MACHINEROOM | MAX.SPEED | MAX.TRAVEL | MAX.LOAD/PERSONS | |
| GP30 (SMR)Passenger Lift | 3000Residential Lift | Economic elevatorwith a compactmachine room | Yes | 2.5m/s | 125m | 1350 kg/up to18 persons | |
| 5000Commercial Lift | High-speed elevatorfor high-rise buildings | Yes | 4.0m/s | 200m | 2000 kg/up to27 persons | ||
| 7000High-speed Lift | Ultra-high-speedelevator forskyscraper buildings | Yes | 8.0m/s | 400m | 1600 kg/up to21 persons | 」 | |
| GPN30 (MRL)Passenger Lift | 3000ResidentialPassenger Lift | Economicalelevator forresidential buildings | No | 1.75m/s | 90m | 1050 kg/up to14 persons | |
| 5000CommercialPassenger Lift | High-speed elevatorfor high-rise buildings | No | 2.5m/s | 125m | 2000 kg/up to27 persons | ||
| Hospital Lift | B5000SSMR Lift | Middle-speedelevator for hospitalbuildings | Yes | 2.5m/s | 125m | 1600 kg/up to21 persons | |
| B5000NMRL Lift | Middle-speedelevator for hospitalbuildings | No | 2.0m/s | 100m | 1600 kg/up to21 persons | ||
| Cargo Lift | F100MR Freight LiftGeared motor | Solid & reliableheavy-duty freightelevator | Yes | 1.0m/s | 50m | 5000kg | |
| F200MR Freight LiftGearless motor | Energy-savingheavy-duty freightelevator | Yes | 1.0m/s | 50m | 3000kg | ||
| FN100MRL Freight LiftGearless motor | Energy and spacesaving heavy-dutyfreight elevator | No | 1.5m/s | 75m | 4000kg | ||
| GA10MR Vehicle Lift | Ideal solution forparking lot andvertical transportation | Yes | 0.5m/s | 25m | 5000kg | ||
| GFH10Hydraulic lift | Unique advantageand adaptability forlimit space | No | 0.5m/s | 25m | 5000kg | ||
| Panoramic Lift | GO10SMR | Wide view withstrong safety glass | Yes | 1.75m/s | 90m | 1600 kg/up to21 persons | |
| GON30MRL | for sighting seeingbuildings | No | 1.75m/s | 90m | 1600 kg/up to21 persons | ||
| GH30Home Lift | 6300Backpack type | Highly customized | No | 0.5m/s | 15m | 410 kg/up to5 persons | |
| 6600Gantry beam type | elevator forhouse/ villa | No | 0.5m/s | 15m | 410kg/up to5 persons | ||
| GE05Escalator | E200/E300/E500 | Adaptableescalator solutionfor publictransportation | 1 | 0.75m/s | 16m | 30°/35° | |
| GM10Moving Walkway | M200 | Adaptablemoving walkwaysolution for publictransportation | 1 | 0.65m/s | 43.47m | 0°/10°/11°/12° | |
| GW05Dumbwaiter | W100 | Small space,applicable tohotels, restaurantsand other places | No | 0.4m/s | 15m | 300 kg |
STANDARD FUNCTION
VVVF Drive
VVVF Door Motor Drive
Full Collective Selective Contral
Attendant Control
Inspection Running
Best Curve Auto-generation
Shaft Auto-tuning/Self-Learning
Weight Signal Compensation
No Load Motor Parameter Identification
Automatic Ooen Door When PowerOn
Automatic Close Door
Landing Calling by LOP
Closing Door Repetition
Opening Door Repetition
Door-open Time Set
Advance Door Closing
Nudging Running
Light Curtain Protection
Over-load Protection
Anti-slip Protection
Up and Down Limit Protection
Over-speed Protection
Leveling Fine Tunning
Fault Diagnosis
Inverted Running
Motor Over-current Protection
Power Over-voltage Protection
Motor Overloac Protection
Anti-nuisance Device
Encoder Failure Protection
Door Lock Short Cut Protection
Motor Temperature Rise Protection
Automatic Retur to Ground Floor
Elevator Lock Device
Electrical Brake Release (MRL
standard)
Parking Switch
Running Status Display
Car PositionAuto-correction
Lighting Fan Energy-saving Function
Car Arrival Chime
Independent Running
Full Load and Non-stop
False Call Cancellation
Floor and Running Direction
Indication
Emergency Light
Inching Operation
Five-way Intercom
Alarm Bell
Fire Emergency Return
Remote Shut-off
User Inspection Set
Time-sharingService
Security Floor in Nighttime
Attendant Reversal
Front/Rear Door Independent Control
VIP Service
Forced Stop
Exchange Stop
Service Floor Set
Mileage Recorder
Time Recorder
Re-leveling
UCMP
Advanced Door Opening
OPTIONAL FUNCTION
ARD (Auto Rescue Device)
IC Card Access Control
Voice Announcer
Air Conditioning
Accessibility Facilities
Wired Remote Monitoring Wireless Remote Monitoring Group Control Operation Duplex Control Operation Seismic Sensor
CCTV Camera Rush Period Service Streaming Media Screen
Planning & Specification
| Load | Speed | Cabin Size | Door Opening | C.W.layout | Door type | Hoistway/Shaft | Pitdepth | Top FloorHeight |
| kg | m/s | CWxCD | EWxEH | HWxHD | PD(mm) | TH(mm) | ||
| 450 | 1 | 1100×1100 | 700×2100 | C.W. atrear | CO | 1600×1800 | 1350 | 4400 |
| 1.5 | 1350 | 4450 | ||||||
| 1.75 | 1350 | 4500 | ||||||
| 630 | 1 | 1400×1100 | 800×2100 | C.W. atrear | CO | 1900×1700 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 630 | 1 | 1100×1400 | 800×2100 | C.W. atside | CO/Doubleentrance | 2000×1900 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 800(825) | 1 | 1400×1350 | 800×2100 | C.W. atrear | CO | 1900×1950 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 800(825) | 1 | 1350×1400 | 800×2100 | C.W. atside | CO/Doubleentrance | 2200×1900 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1000(1050) | 1 | 1600×1450 | 900×2100 | C.W. atrear | CO | 2100×2050 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1000(1050) | 1 | 1400×1600 | 900×2100 | C.W. atside | CO/Doubleentrance | 2300×2100 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1000(1050)(Bed lift) | 1 | 1100×2100 | 900×2100 | C.W. atside | SO | 1850×2550 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1000(1050)(Bed lift) | 1 | 1100×2100 | 900×2100 | C.W. atside | CO | 2050×2500 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1150 | 1 | 1800×1400 | 1000×2100 | C.W. atrear | CO | 2300×2100 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 |
| Load | Speed | Cabin Size | Door Opening | Entrance | Door type | Hoistway/Shaft | Pitdepth | Top FloorHeight |
| kg | m/s | CW×CD | EWxEH | HW×HD | PD(mm) | TH(mm) | ||
| 800(825) | 2 | 1400×1350 | 800×2100 | Single | CO | 2000×2150 | 2000 | 5000 |
| 2.5 | 2100 | 5100 | ||||||
| 1000(1050) | 2 | 1600×1450 | 900×2100 | Single | CO | 2200×2200 | 2000 | 5000 |
| 2.5 | 2100 | 5100 | ||||||
| 1150 | 2 | 1800×1400 | 1000×2100 | Single | CO | 2400×2200 | 2000 | 5000 |
| 2.5 | 2100 | 5100 | ||||||
| 1250 | 2 | 1900×1500 | 1100×2100 | Single | CO | 2500×2300 | 2000 | 5000 |
| 2.5 | 2100 | 5100 | ||||||
| 1350 | 2 | 1900×1600 | 1100×2100 | Single | co | 2500×2400 | 2000 | 5000 |
| 2.5 | 2100 | 5100 |
| Load | Speed | Cabin Size | Door Opening | C.W.layou | Door typet | Hoistway/Shaft | Pit depth | Top FloorHeight |
| $k \varrho$ | m/s | CWxCD | EWxEH | HWxHD | PD(mm) | TH(mm) | ||
| 450 | 1 | 1100×1100 | 700×2100 | C.W. atside | CO | 1900×1500 | 1500 | 4250 |
| 1.5 | 1550 | 4350 | ||||||
| 1.75 | 1600 | 4400 | ||||||
| 630 | 1 | 1100×1400 | 700×2100 | C.W. atside | CO | 1850×1850 | 1500 | 4250 |
| 1.5 | 1550 | 4350 | ||||||
| 1.75 | 1600 | 4400 | ||||||
| 630 | 1 | 1100×1400 | 700×2100 | C.W. atside | CO/Doubleentrance | 1850×1900 | 1500 | 4250 |
| 1.5 | 1550 | 4350 | ||||||
| 1.75 | 1600 | 4400 | ||||||
| 800(825) | 1 | 1350×1400 | 800×2100 | C.W. atside | CO | 2100×1850 | 1500 | 4250 |
| 1.5 | 1550 | 4350 | ||||||
| 1.75 | 1600 | 4400 | ||||||
| 800(825) | 1 | 1350×1400 | 800×2100 | C.W. atside | CO/Doubleentrance | 2100×1900 | 1500 | 4250 |
| 1.5 | 1550 | 4350 | ||||||
| 1.75 | 1600 | 4400 | ||||||
| 1000(1050) | 1 | 1600×1450 | 900×2100 | C.W. atside | CO | 2350×1900 | 1500 | 4250 |
| 1.5 | 1550 | 4350 | ||||||
| 1.75 | 1600 | 4400 | ||||||
| 1000(1050) | 1 | 1400×1600 | 900×2100 | C.W. atside | CO/Doubleentrance | 2250×2100 | 1500 | 4250 |
| 1.5 | 1550 | 4350 | ||||||
| 1.75 | 1600 | 4400 | ||||||
| 1000(1050)(Bed lift) | 1 | 1100×2100 | 900×2100 | C.W. atside | SO | 1850×2550 | 1500 | 4350 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 | ||||||
| 1000(1050)(Bed lift) | 1 | 1100×2100 | 900×2100 | C.W. atside | CO | 2100×2500 | 1500 | 4350 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 | ||||||
| 1150 | 1 | 1800×1400 | 1100×2100 | C.W. atside | CO | 2700×1800 | 1500 | 4350 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 |
Planning & Specification
| Load | Speed | Cabin Size | Door Opening | C.W.layout | Door type | Hoistway/Shaft | Pitdepth | TopFloorHeight |
| kg | m/s | CW×CD | EW×EH | HW×HD | PD(mm) | TH(mm) | ||
| 800(825) | 1 | 1400×1350 | C.W. atrear | co | 1900×1950 | 1350 | 4400 | |
| 1.5 | 800×2100 | 1350 | 4450 | |||||
| 1.75 | 1350 | 4500 | ||||||
| 800(825) | 1 | 1350×1400 | 800×2100 | C.W. atside | CO/Doubleentrance | 2200×1900 | 1350 | 4400 |
| 1.5 | 1350 | 4450 | ||||||
| 1.75 | 1350 | 4500 | ||||||
| 1000 | 1 | 1600×1400 | 900×2100 | C.W. atrear | cO | 2100×2000 | 1350 | 4400 |
| 1.5 | 1350 | 4450 | ||||||
| 1.75 | 1350 | 4500 | ||||||
| 1000 | 1 | 1400×1600 | 900×2100 | C.W. atside | CO/Doubleentrance | 2300×2100 | 1350 | 4400 |
| 1.5 | 1350 | 4450 | ||||||
| 1.75 | 1350 | 4500 | ||||||
| 1000(1050) | 1 | 1100×2100 | 900×2100 | C.W. atside | SO | 1850×2550 | 1350 | 4400 |
| 1.5 | 1350 | 4450 | ||||||
| Bed lift | 1.75 | 1350 | 4500 | |||||
| 1000(1050)Bed lift | 1 | 1100×2100 | 900×2100 | C.W. atside | co | 2050×2500 | 1350 | 4400 |
| 1.5 | 1350 | 4450 | ||||||
| 1.75 | 1350 | 4500 | ||||||
| 1050 | 1 | 1600×1500 | 900×2100 | C.W. atrear | co | 2100×2100 | 1350 | 4400 |
| 1.5 | 1350 | 4450 | ||||||
| 1.75 | 1350 | 4500 | ||||||
| 1050 | 1 | 1500×1600 | 900×2100 | C.W. atside | CO/Doubleentrance | 2400×2100 | 1350 | 4400 |
| 1.5 | 1350 | 4450 | ||||||
| 1.75 | 1350 | 4500 | ||||||
| 1150 | 1 | 1000×2100 | C.W. atrear | cO | 2300×2100 | 1350 | 4400 | |
| 1.5 | 1800×1400 | 1350 | 4450 | |||||
| 1.75 | 1350 | 4500 | ||||||
| 1250 | 1 | 1100×2100 | C.W. atrear | CO | 2400×2300 | 1400 | 4450 | |
| 1.5 | 1900×1500 | 1450 | 4500 | |||||
| 1.75 | 1450 | 4600 | ||||||
| 1350 | 1 | 1900×1600 | 1100×2100 | C.W. atrear | co | 2400×2400 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1600 | 1 | 2000×1700 | 1200×2100 | C.W. atrear | co | 2600×2500 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1600 | 1 | 1400×2400 | 1200×2100 | C.W. atside | SC | 2400×2900 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 2000 | 1 | 2000×2000 | 1100×2100 | C.W. atrear | CO | 2600×2800 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 2000 | 1 | 1600×2600 | 1200×2100 | C.W atside | co | 2900×3000 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 |
| Load | Speed | Cabin Size | Door Opening | C.W.layout | Door type H | oistway/Shaft | Pit depth | Top FloorHeight |
| kg | m/s | CW×CD | EWxEH | HWxHD | PD(mm) | TH(mm) | ||
| 800(825) | 1 | 1350×1400 | 800×2100 | C.W.atside | co | 2100×1850 | 1500 | 4250 |
| 1.5 | 1550 | 4300 | ||||||
| 1.75 | 1600 | 4350 | ||||||
| 800(825) | 1 | 1350×1400 | 800×2100 | C.W. atside | CO/Doubleentrance | 2100×1900 | 1500 | 4250 |
| 1.5 | 1550 | 4300 | ||||||
| 1.75 | 1600 | 4350 | ||||||
| 1000 | 1 | 1600×1400 | 900×2100 | C.W. atsida | co | 2350×1850 | 1500 | 4250 |
| 1.5 | 1550 | 4300 | ||||||
| 1.75 | 1600 | 4350 | ||||||
| 1000(1050)Bed lift | 1 | 1100×2100 | 900×2100 | C.W. atside | CO | 2050×2500 | 1500 | 4400 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 | ||||||
| 1050 | 1 | 1600×1500 | 900×2100 | C.W. atsidə | Co | 2100×2100 | 1500 | 4400 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 | ||||||
| 1150 | 1 | 1800×1400 | 1000×2100 | C.W. atsidə | co | 2300×2100 | 1500 | 4400 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 | ||||||
| 1250 | 1 | 1900×1500 | 1100×2100 | C.W. atside | co | 2700×1900 | 1550 | 4150 |
| 1.5 | 1600 | 4200 | ||||||
| 1.75 | 1650 | 4250 | ||||||
| 1350 | 1 | 1900×1600 | 1100×2100 | C.W.atside | co | 2700×2000 | 1550 | 4150 |
| 1.5 | 1600 | 4200 | ||||||
| 1.75 | 1650 | 4250 | ||||||
| 1600 | 1 | 2000×1800 | 1200×2100 | C.W.atside | cO | 2850×2200 | 1550 | 4200 |
| 1.5 | 1600 | 4250 | ||||||
| 1.75 | 1650 | 4300 | ||||||
| 2000 | 1 | 2000×2000 | 1100×2100 | C.W. atside | co | 2850×2400 | 1550 | 4200 |
| 1.5 | 1600 | 4250 | ||||||
| 1.75 | 1650 | 4300 |
Planning & Specification
| Load | Speed | Cabin Size | Door Opening | Holstway/Shaft | Pltdepth | Top FloorHeight |
| kg | m/s | CW×CD | EWxEH | HWxHD | PD(mm) | TH(mm) |
| 400 | 1 | 1000×1000 | 2S 800×2000 | 1550×1500 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 400 | 1 | 1000×1000 | CO 700×2000 | 1550×1400 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 450 | 1 | 1100×1100 | 2S 800×2000 | 1650×1500 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 450 | 1 | 1100×1100 | CO 700×2000 | 1650×1450 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 630 | 1 | 1100×1400 | 2S 900×2000 | 1650×1800 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 630 | 1 | 1100×1400 | CO 700×2000 | 1650×1700 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 800 | 1 | 1350×1400 | CO 800×2000 | 1900×1700 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 1000 | 1 | 2100×1100 | 2S 1200×2000 | 2650×1650 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 1000 | 1 | 1600×1400 | CO 1000×2000 | 2150×1700 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 1000 | 1 | 1100×2100 | 2S 900×2000 | 1650×2500 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 | ||||
| 1000 | 1 | 1100×2100 | CO 800×2000 | 1800×2400 | 1300 | 3600 |
| 1.5 | 1400 | 3800 | ||||
| 1.75 | 1400 | 3800 |
Special designed passenger elevator structure for narrow space shaft and low overhead.
| Load | Speed | Cabin Size | Door Opening | Holstway/Shaft | Pltdepth | Top FloorHeight | |
| kg | m/s | CW×CD | EWxEH | HWxHD | PD(mm) | TH(mm) | |
| 400 | 1 | 1000×1000 | 2S 800×2000 | 1550×1500 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 400 | 1 | 1000×1000 | CO 700×2000 | 1550×1400 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 450 | 1 | 1100×1100 | 2S 800×2000 | 1650×1500 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 450 | 1 | 1100×1100 | CO 700×2000 | 1650×1450 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 630 | 1 | 1100×1400 | 2S 900×2000 | 1650×1800 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 630 | 1 | 1100×1400 | CO 700×2000 | 1650×1700 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 800 | 1 | 1350×1400 | CO 800×2000 | 1900×1700 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 1000 | 1 | 2100×1100 | 2S 1200×2000 | 2650×1650 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 1000 | 1 | 1600×1400 | CO 1000×2000 | 2150×1700 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 1000 | 1 | 1100×2100 | 2S 900×2000 | 1650×2500 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
| 1000 | 1 | 1100×2100 | CO 800×2000 | 1800×2400 | 1200 | 3400 | |
| 1.5 | 1300 | 3600 | |||||
| 1.75 | 1300 | 3600 | |||||
Special designed passenger elevator structure for narrow space shaft and low overhead.
Panoramic elevator
— WIDER RANGE OF BEAUTIFUL VIEW
Ceiling design
G1019 Middle section as white lighting, the round section as stainless steel with lambency lighting
Cabin design
GO09
Upper and lower cover :
hairline St./St.
Ceiling (G1017) : Hairline St./ St., White transparent acrylic plate
COP (G2116): Hairline St./St. Handrail (G6019) : Circular hairline St./St.
Car wall : Hairline St./
St., Safety laminated glass Floor (G3313) : Marble
GO11
Upper and lower cover :
hairline St./St.
Ceiling (G1013) : Hairline St./ St., White transparent acrylic plate
COP (G2112) : Hairline St./St. Handrail (G6019) : Circular hairline St./St.
Car wall : Hairline St./
St., Safety laminated glass Floor (G3313): Marble
GO14
Upper and lower cover :
hairline St./St.
Ceiling (G1020) : Hairline St./ St., White transparent acrylic plate
COP (G2112) : Hairline St./St. Handrail(G6013): Circular hairline St./St.
Car wall : Hairline St./
St., Safety laminated glass Floor (G3108) : PVC
GO10
Upper and lower cover :
hairline St./St.
Ceiling (G1011) : Hairline St./ St., White transparent acrylic plate
COP (G2116): Hairline St./St. Handrail (G6019) : Circular hairline St./St.
Car wall : Hairline St./
St., Safety laminated glass Floor (G3313) : Marble
GO12
Upper and lower cover :
hairline St./St.
Ceiling (G1013) : Hairline St./ St., White transparent acrylic plate
COP (G2112) : Hairline St./St. Handrail (G6001): Circular hairline St./St.
Car wall : Hairline St./
St., Safety laminated glass Floor (G3313) : Marble
GO15
Upper and lower cover :
hairline St./St.
Ceiling (G1019) : Hairline St./ St., White transparent acrylic plate
COP (G2112) : Hairline St./St. Handrail(G6013): Circular hairline St./St.
Car wall : Hairline St./
St., Safety laminated glass Floor (G3108) : PVC
Planning & Specification
| Load | Speed | Cabin Size | Door Opening | Hoistway/Shaft | Pitdepth | Top FloorHeight | ||||
| kg | m/s | CW×CD | EW×EH | HW×HD | PD(mm) | TH(mm) | ||||
| 630 | 1 | 1100×1400 | CO 700×2100 | 2000×2000 | 1800 | 4500 | ||||
| 1.5 | 1850 | 4600 | ||||||||
| 1.75 | 1900 | 4650 | ||||||||
| 630 | 1 | 1100×1600 | CO 700×2100 | 2000×2200 | 1800 | 4500 | ||||
| 1.5 | 1850 | 4600 | ||||||||
| 1.75 | 1900 | 4650 | ||||||||
| 800 | 1 | 1300×1500 | CO 800×2100 | 2200×2100 | 1850 | 4600 | ||||
| 1.5 | 1900 | 4650 | ||||||||
| 1.75 | 1950 | 4700 | ||||||||
| 800 | 1 | 1200×1750 | CO 800×2100 | 2100×2350 | 1850 | 4600 | ||||
| 1.5 | 1900 | 4650 | ||||||||
| 1.75 | 1950 | 4700 | ||||||||
| 1000 | 1 | 1500×1500 | CO 900×2100 | 2400×2100 | 1900 | 4650 | ||||
| 1.5 | 1950 | 4700 | ||||||||
| 1.75 | 2000 | 4750 | ||||||||
| 1000 | 1 | 1300×1900 | CO 900×2100 | 2200×2500 | 1900 | 4650 | ||||
| 1.5 | 1950 | 4700 | ||||||||
| 1.75 | 2000 | 4750 | ||||||||
| 1250 | 1 | 1600×1700 | CO 1000×2100 | 2500×2300 | 2000 | 4750 | ||||
| 1.5 | 2050 | 4800 | ||||||||
| 1.75 | 2100 | 4850 | ||||||||
| 1250 | 1 | 1500×2000 | CO 900×2100 | 2400×2600 | 2000 | 4750 | ||||
| 1.5 | 00 | 2050 | 4800 | |||||||
| 1.75 | 2100 | 4850 | ||||||||
| 1350 | 1 | 1800×1700 | CO 1100×2100 | 2700×2300 | 2050 | 4800 | ||||
| 1.5 | 2100 | 4850 | ||||||||
| 1.75 | 2150 | 4900 | ||||||||
| 1350 | 1 | CO 1100×2100 | 2500×2600 | 2050 | 4800 | |||||
| 1.5 | 1600×2000 | 2100 | 2100 | 4850 | ||||||
| 1.75 | 2150 | 4900 | ||||||||
| 1600 | 1 | 1900×1800 | CO 1100×2100 | 2900×2400 | 2150 | 4900 | ||||
| 1.5 | 400 | 2200 | 4950 | |||||||
| 1.75 | 2250 | 5000 | ||||||||
| 1600 | 1 | CO 1100×2100 | 2800×2700 | 2150 | 4900 | |||||
| 1.5 | 1800×2100 | 2200 | 4950 | |||||||
| 1.75 | 2250 | 5000 | ||||||||
| Load | Speed | Cabin Size | Door Opening | Hoistway/Shaft | Pitdepth | Top FloorHeight |
| kg | m/s | CW×CD | EWxEH | HW×HD | PD(mm) | TH(mm) |
| 630 | 1 | 1100×1400 | CO 700×2100 | 2000×2000 | 1700 | 4650 |
| 1.5 | 1750 | 4700 | ||||
| 1.75 | 1800 | 4750 | ||||
| 630 | 1 | 1100×1600 | CO 700×2100 | 2000×2200 | 1700 | 4650 |
| 1.5 | 1750 | 4700 | ||||
| 1.75 | 1800 | 4750 | ||||
| 800 | 1 | 1300×1500 | CO800×2100 | 2200×2100 | 1750 | 4650 |
| 1.5 | 1800 | 4700 | ||||
| 1.75 | 1850 | 4750 | ||||
| 800 | 1 | 1200×1750 | CO 800×2100 | 2100×2350 | 1750 | 4650 |
| 1.5 | 1800 | 4700 | ||||
| 1.75 | 1850 | 4750 | ||||
| 1000 | 1 | 1500×1500 | CO 900×2100 | 2400×2100 | 1800 | 4700 |
| 1.51.75 | 1850 | 4750 | ||||
| 1900 | 4800 | |||||
| 1000 | 1 | 1300×1900 | CO900×2100 | 2200×2500 | 1800 | 4700 |
| 1.51.75 | 1850 | 4750 | ||||
| 1900 | 4800 | |||||
| 1250 | 1 | 1600×1700 | CO 1000×2100 | 2500×2300 | 1900 | 4800 |
| 1.51.75 | 1950 | 4850 | ||||
| 2000 | 4900 | |||||
| 1250 | 1 | 1500×2000 | CO 900×2100 | 2400×2600 | 1900 | 4800 |
| 1.5 | 1950 | 4850 | ||||
| 1.75 | 2000 | 4900 |
Hospital elevator
— OPTIMUM PERFORMANCE IN HIGHLY DEMANDING
Concerned with people's safety and health, Joylive hospital elevator complies with the latest International Building Code (IBC). To protect user's safety, Joylive hospital elevators are made with reliable rescue-specific system design, scientific car space planning, and more convenience in emergency. suitable for hospitals/ health care centers/emergency inspection centers and other medical institutions.
Special space design Suitable for stretchers
Rear C.W. shaft layout, car was widened to a width of 2100mm, door width was increased, suitable for access of rescue stretcher.
Side C.W. shaft layout, focus on car depth design, suitable for rescue stretcher enter.
360° view
CABIN DESIGN
G5155 Standard
Celling (G1010) : Hairline St./St., Acrylic Plate, LED Lighting
Car wall : Hairline St./St., Mirror St./St.
COP (G2116) : Hairline St./St.
Handrail (G6001) : Hairline St./St.
Floor : PVC
G5156 Optional
Ceiling (G1017) : Hairline St./St., Acrylic Plate, LED Lighting
Car wall : Hairline St./St., MirrorSt./St.
COP (G2116) : Hairline St./St.
Handrail (G6001) : Hairline St./St.
Floor (G3124): PVC
Planning & Specification for B310(MR)
| LoadKg | Speedm/s | Car DimensionCWxCD | Door OpeningEWxEH | Entrance | Door type | Shaft DimensionHWxHD | Pit DepthPd (mm) | Top FloorHeightTh (mm) |
| 1600 | 1 | 1400X2400 | 1200X2100 | Singleentrance | sO | 2300X2900 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1600 | 1 | 1400X2400 | 1200X2100 | Doubleentrance | so | 2300X3050 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1600 | 1 | 1400X2400 | 1200X2100 | Singleentrance | co | 2600X2800 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 | ||||||
| 1600 | 1 | 1400X2400 | 1200X2100 | Doubleentrance | CO | 2600X2900 | 1400 | 4450 |
| 1.5 | 1450 | 4500 | ||||||
| 1.75 | 1450 | 4600 |
Planning & Specification for BN320(MRL)
| LoadKg | Speedm/s | Car DimensionCWxCD | Door OpeningEWxEH | Entrance | Door type | Shaft DimensionHWxHD | Pit DepthPd (mm) | Top FloorHeightTh (mm) |
| 1600 | 1 | 1400X2400 | 1200X2100 | Singleentrance | sO | 2300X2900 | 1500 | 4350 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 | ||||||
| 1600 | 1 | 1400X2400 | 1200X2100 | Doubleentrance | sO | 2300X3050 | 1500 | 4350 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 | ||||||
| 1600 | 1 | 1400X2400 | 1200X2100 | Singleentrance | CO | 2650X2800 | 1500 | 4350 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 | ||||||
| 1600 | 1 | 1400X2400 | 1200X2100 | Doubleentrance | CO | 2650X2900 | 1500 | 4350 |
| 1.5 | 1550 | 4450 | ||||||
| 1.75 | 1600 | 4500 |
Escalator & Moving Walk
— DEPENDABLE PERFORMANCE AND PASSENGER SAFETY
Versatile escalator and inclined moving walk that meets the specific requirements of commercial buildings and public transport applications; with various configuration packages, dependable performance and passenger safety.
Customized solutions to meet the diverse functions of public buildings and passenger flow demand.
Safety device and function options
Comply with European EN115latest standard design, 30 safety protection devices and functions.
Standard device
Optional device
Phase lack/loss protection Motor overload protection Electrical circuit protection Handrail inlet protection Comb plate safety protection device Step sagging protection device Drive chain broken protection Step chain broken protection Over-speed protection Direction reversal protection
Security line
Emergency stop button
Skirt panel protection
Brake protection
Inspection safety switch
Warning lightings
Alarm bell starting device
Handrail broken protection device
Handrail speed monitoring
Skirting brush
Standard function
Fire linkage Additional brake
Handrail inlet entrance Automatic lubrication Roller built-in stəp chain Fault indication Step warning light Two-way operation Emergency stop Inspection running
Optional function
Running direction indication
Auto start/stop
Handrail illumination
Comb illumination
Skirt illumination
Heating device
Oil/water separator(Outdoor type)
Frequency conversion control
Layout Planning for Escalator E200
30° Planning drawing (Rising height≤6M)
Zoom in plot A
Specification and dimension
| StepWidth(MM) | Rising height (MM) | Power |
| 1000 | 1500-3200 | 5.5 |
| 3200-4800 | 8 | |
| 4800-6000 | 11 | |
| 800 | ≤4200 | 5.5 |
| 4200-6000 | 8 | |
| 600 | ≤6000 | 5.5 |
| Support reaction | |||
| Step width | |||
| 600 | 800 | 1000 | |
| R1(KN) | 3.5 x L+15.5 | 4 x L+17 | 4.5 x L+18.5 |
| R2(KN) | 3.5 x L+10 | 4 x L+11 | 4.5 x L+11.5 |
| A | Step width | 600 | 800 | 1000 |
| B | Decoration width | 1140 | 1340 | 1540 |
| C | Construction width | 1200 | 1400 | 1600 |
| D | Handrail distance | 838 | 1038 | 1238 |
| E | Construction width | 1838 | 2038 | 2178 |
| F | Construction width | 1200 | 1400 | 1600 |
1. The drawing is only applied for single arrangement escalator with rise under 6meters. 2. The upside of truss shauld be extended 417 mmin case of 600 mm stem.
35° Planning drawing (Rising height≤6M)
Zoom in plot A
Specification and dimension
| Support reaction | |||
| Step width | |||
| 600 | 800 | 1000 | |
| R1(KN) | $3 . 5 \times 1 + 1 5 . 5$ | $4 \times 1 + 1 7$ | $4 . 5 \times \mathsf { L } + 1 8 . 5$ |
| R2(KN) | $3 . 5 \times 1 + 1 0$ | $4 \times 1 + 1 1$ | $4 . 5 \times \mathsf { L } + \mathsf { 1 } \mathsf { 1 } . 5$ |
| StepWidth(Mm) | Rising height (mm) | Power |
| 1000 | 1500-3500 | 5.5 |
| 3500-5000 | 8 | |
| 5000-6000 | 11 | |
| 800 | ≤4500 | 5.5 |
| 4500-6000 | 8 | |
| 600 | ≤6000 | 5.5 |
| A | Step width | 600 | 800 | 1000 |
| B | Decoration width | 1140 | 1340 | 1540 |
| C | Construction width | 1200 | 1400 | 1600 |
| D | Handrail distance | 838 | 1038 | 1238 |
| E | Construction width | 1838 | 2038 | 2178 |
| F | Construction width | 1200 | 1400 | 1600 |
1. The drawing is only applied for single arrangement escalator with rise under 6 meters. 2. The upsicle of truss should be extended 417 mm in case of 600 mm stem.
Layout Planning for Moving walkway M200