LANSO
MEDIUM VOLTAGE
LANSO KONLY (SHANGHAI) INSTRUMENTS CO.,LTD.
Lanso Konly (Shanghai) Instruments Co., Ltd. is an innovation-driven and high-tech enterprise. The company is committed to creating globally leading SF, and other alternative insulating gas monitoring solutions and digital transformer accessories series products.
Backed by cutting-edge technology, the company has established a full-fledged industrial ecosystem spanning R&D, production, marketing, and technical services, continuously safeguarding the operation of power equipment worldwide.
In technology and market development, Lanso Instruments relies on its independent R&D innovation platform and holds multiple technicalinvention patents. With technological breakthroughs in segmented fields, the company has been awarded a numberof authoritativequalifications, including the Little GiantEnterprise, National Key "Little Giant" Enterprise, 2024 Shanghai Manufacturing Single Champion and ShanghaiGreen Factory. Our products have been exported to more than 20 countries worldwide, covering France, Germany, Italy, Spain, India and other regions.
In globalization strategy,the company has established deep strategic partnerships with international electrical giants like ABB, HITACHI, Schneider, and Siemens, while maintaining long-term collaborations with leading domesticswitchgear companies such as Taikai Group (TK), Sieyuan Electric, Pinggao Electric (PG), and China XD Group etc.
The companyalways puts quality management at the core of its development. Through scientific and standardized management systems as well as rigorous and comprehensive management measures, it fully ensures stable product quality and reliable performance. The company has obtained authoritative certifications from Swiss SGS, including ISO 9001 Quality Management System, ISO 14001 Environmental Management System, ISO45001Occupational Health and Safety Management System, ISO 56005 Innovation and Intellectual Property Management System, as well as ISO 50001, ISO 14064 and ISO 14067 etc. Meanwhile, the enterprise has established a full-chain quality traceability system covering raw material procurement, production and manufacturing to finished product delivery, enabling whole-process quality control and full traceability.
The company's product portfolio includes three major series. The insulation gas monitoring series includes various digital density monitors (density meters), density switches, density transmitters, and valves. The transformer accessories series mainly includes intelligent buchholz relays, oil temperature indicators, and oil level indicators. The equipment and instruments series mainly includes gas density relay calibrators.
With outstanding technological strength, strict quality management, and a global strategy, Lanso Instruments is innovation-driven and quality-backed, continuously leading industry development and contributing to the intelligent and green transformation of the global power industry.
CONTENTS
KL50 Pressure Gauge 02
KL60 Density Meter 04
KL60R 06
Remote-Transmission Density Meter
ZMJ60 Density Monitor 08
ZMJ60R Density Monitor 10
ZMJ60V Density Monitor 12
DDM60R Digital Density Monitor 14
DT26 Density Transmitter 16
DT10 Density Transmitter 18
RD40 Density Transmitter 20
RDH40 22
SF Gas Density and Dew Transmitter
MDK40 Density Switch 24
CV Self-Sealing Valve 26
FMZ Connection Valves 28
VDA-03 Gas Density Monitor Calibrator 30
JXQ Series RS485 Hub 32
DA Series 34
Digital Meter Monitoring Terminal
GLM Type SF₆ Gas 36
Leakage Quantitative Alarm System
SF₆ Gas Monitor and Receiver Based on 38
LoRa Wireless Transmission Technology
KL50 Pressure Gauge
Description
KL50 Pressure Gauges are used to monitor the pressure of the gas in sealed tanks. They are applied to indicate the relative pressure of the gas on site. They are designed to monitor Medium Voltage systems.
Features
Display the relative pressure of the gas in the closed container at real-time temperature.
Suitable for indoor or outdoor installation.
AISI 304 hermetically sealed stainless steel case.
Gas connection tubes are made of AISI 316 stainless steel.
Application
SF6 Gas Insulated RMU
{ \mathsf { S F } } _ { 6 } Gas Insulated Switchgear
Options
Pressure connection: customizable
Measuring medium: SF6, Air, \mathsf { N } _ { 2 } , SF₆+ { \Nu } _ { 2 } and other gases
Wide temperature range: { \mathsf { - 4 0 } } ^ { \circ } \mathsf { C } to +60℃
| Technical Parameters | |
| Case diameter | 50mm |
| Scale range | 0 to 0.6 bar |
| Accuracy | $\pm 1 . 5 \% 5 5 ( + 2 0 \pm 1 ^ { \circ } \mathsf { C } )$ $\pm 2 . 5 \% 5 5 ( - 2 0 ^ { \circ } C \sim + 6 0 ^ { \circ } C )$ (gas phase) |
| Ambient conditions | $- 2 0 ^ { \circ } \mathsf { C } \mathsf { t o } + 6 0 ^ { \circ } \mathsf { C } ,$ relative humidity ≤ 95%RH |
| Leakage rate | $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P a } { \cdot } \mathsf { m } ^ { 3 } / \mathsf { s }$ (Helium leakage inspection) |
| Process connection | ${ \sf M } 2 4 \times 1 . 5$ (customizable) |
| Installation method | Radial or Axial |
| Window glass | Laminated safety glass |
| Weight | 0.2kg |
Dimensions
KL60 Density Meter
Description
KL 60 Density Meters are used to monitor { \mathsf { S F } } _ { 6 } gas density in sealed tanks. They are applied to indicate gas density. They are designed to monitor Medium Voltage systems.
Features
Bimetal temperature compensation ensures higher measurement accuracy.
Suitable for indoor or outdoor installation.
AISI 304 hermetically sealed stainless steel case.
Gas connection tubes are made of AISI 316 stainless steel.
The on-screen display value and output signals are independent of the impact of external environment, such as altitude.
Application
{ \mathsf { S F } } _ { 6 } Gas Insulated RMU
{ \mathsf { S F } } _ { 6 } Gas Insulated Switchgear
Options
Process connection: customizable
Measuring Medium: { \mathsf { S F } } _ { 6 } , Air, \mathsf { N } _ { 2 } , \mathsf { S F } _ { 6 } + \mathsf { N } _ { 2 } and other gases
Suitable for High-altitude environment
Wider temperature range: -40°C to +60°C
Optional measurement accuracy: ±1.0%FS (+20± 1C) , ±2.5%FS (-20°℃~ +60°C)(gas phase)
| Technical Parameters | |
| Case diameter | 64mm |
| Scale range | 1 to 2bar abs |
| Accuracy | ±1.5%FS (+20±1C),±2.5%FS (-20°℃~ +60°C) (gas phase) |
| Degree of protection | IP65 |
| Ambient conditions | $- 2 0 ^ { \circ } \mathsf { C } \mathsf { t o } + 6 0 ^ { \circ } \mathsf { C } ,$ relative humidity ≤ 95%RH |
| Leakage rate | $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P a } { \cdot } \mathsf { m } ^ { 3 } / \mathsf { s }$ (Helium leakage inspection) |
| Process connection | ${ \sf M } 2 4 \times 1 . 5$ (customizable) |
| Installation method | Radial or Axial |
| Watch glass | Laminated safety glass |
| Impact rating | 30g |
| Weight | $\approx 0 . 2 \mathsf { k g }$ |
| Pressure element | Bourdon tubes |
Dimensions
KL60R Remote-Transmission Density Meter
Description
These instruments are used to monitor the density of SF₆ gas in sealed tanks and can be widely used in medium voltage switchgear and RMU.They are applied to indicate the gas density and reliably output SF₆ gas density signal for remote monitoring.
They can provide multiple solutions to support new substations and the intelligent transformation of existing substations.
Features
Volume minimization,customized installation interface,convenient and reliable.
Pressure interface customized in accordance with customer's demands.
Utmost three pairs of switching contacts can be provided according to user's needs.
The RS485 remote function ensures remote monitoring.
Application
{ \mathsf { S F } } _ { 6 } gas Insulated RMU
■ { \mathsf { S F } } _ { 6 } gas Insulated Switchgear
Options
Measuring range
Ambient condition
Outlet Direction and cable length
Installation method
Suitable for High-altitude environment
Measurement Medium: SF6, Air, N2, \mathsf { S F } _ { 6 } + \mathsf { N } _ { 2 } and other gases
| Technical Parameters | |
| Case diameter | Φ64mm |
| Scale range | 1.0 to 2bar abs |
| Accuracy | a) At 20° C: Class 1.0 or 1.5b) -40° C to +60° C: Class 2.5 |
| Degree of protection | IP65 |
| Ambient conditions | $^ { - 4 0 ^ { \circ } } \mathsf { C } \mathsf { t o } ^ { + 6 0 ^ { \circ } } \mathsf { C } ,$ relative humidity ≤ 95%RH |
| Leakage rate | ≤ 1 × 10-9 Pa·m3/s (Helium leakage inspection) |
| Process connection | M24×1.5 (customizable) |
| Installation method | radial or axial |
| Weight | 0.3kg |
Dimensions
ZMJ60 Density Monitor
Description
ZMJ60 Density Monitors are used to monitor the density of SF6 gas in sealed tanks and can be widely used in medium voltage switchgear and RMU. They' re also suitable for outdoor harsh conditions.
They can provide multiple solutions to support new substations and the renovation and upgrading of existing substations.
Features
Compact design, customizable installation interface, convenient and reliable.
Process connection customizable in accordance with customer's demands.
Up to three sets of switching contacts can be provided according to user's needs.
Temperature compensation for higher accuracy.
Application
SF6 Gas Insulated RMU
{ \mathsf { S F } } _ { 6 } Gas Insulated Switchgear
Options
Different measuring ranges
Wider temperature range: -40°C to +60°C
Outlet Direction and cable length
Installation method
Suitable for High-altitude environment
Can detect SF₆、Air、N₂、SF₆+N₂ and other gases
Optional measurement accuracy: ±1.0%FS (+20± 1°C) , ±2.5%FS (-20°℃~ +60°C)(gas phase)
| Technical Parameters | |
| Case diameter | Φ64mm |
| Case material | Stainless steel |
| Scale range | 0 to 2bar abs. (customizable) |
| Accuracy | ±1.5%FS (+20±1° C)±2.5%FS (-20° C ~ +60° C) (gas phase) |
| Ambient conditions | $- 2 0 ^ { \circ } \mathsf { C } \mathsf { t o } + 6 0 ^ { \circ } \mathsf { C } ,$ relative humidity ≤ 95%RH |
| Degree of protection | IP65 |
| Leakage rate | $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P a } { \cdot } \mathsf { m } ^ { 3 } /$ s(Helium leakage inspection) |
| Contact type | Magnetic snap-action contacts (up to 3 sets, NO or NC) |
| Process connection | M20×1.5 (customizable) |
| Installation method | Radial or Axial |
| Insulation properties | Insulation resistance: >100 MΩ (500 V DC)Withstand voltage: 2kV, 50/60 Hz 1 min |
| Contact electrical parameters | Rated Power: 30VAMax operating voltage: 380VMax current: 1A |
| Weight | ≈0.5kg |
| Pressure Element | Bourdon tubes |
Dimensions
Description
ZMJ60R Density Monitors is used to monitor the density of gas in closed containers, and can be widely used in medium voltage switchgear and ring network cabinet. It can display gas density on site, and reliably output SF6 gas density signal for remote monitoring and monitoring. It can be used in the new substation building and renovation and upgrading of existing substation.
Features
Compact design, customizable installation interface to user'sneed, convenient and reliable.
Suited for different indoor and outdoor installation requirements.
Up to three sets of contact switches.
RS485 remote transmission function, convenient remote monitoring.
Temperature compensated.
Application
█ { \mathsf { S F } } _ { 6 } Gas Insulated Ring Main Unit
{ \mathsf { S F } } _ { 6 } Gas Insulated Switch Gear
Options
Measuring range
Wider temperature range: * 4 0 ^ { \circ } C ~ + 6 0 ^ { \circ } C
Outlet mode and cable length
Installation method
High altitude environment application
Measuring Medium: \mathsf { S F } _ { 6 } , \mathsf { A i r } , \mathsf { N } _ { 2 } , \mathsf { S F } _ { 6 } + \mathsf { N } _ { 2 } and other gases
Optional measurement accuracy. ±1.0%FS(+20± 1C),±2.5%FS ( - 2 0 ^ { \circ } C ~ + 6 0 ^ { \circ } C ) (gas phase)
Technical Parameters for Remote Module
| Operating voltage | 10~30VDC | EMC Class | IEC61000-4-2: Level 4 |
| Power consumption | <0.5W | IEC61000-4-3: Level 3 IEC61000-4-4: Level 4 | |
| Communication mode | RS485 | IEC61000-4-5: Level 3 | |
| Communication protocol | Modbus RTU | IEC61000-4-6: Level 3 | |
| Baud rate | 9600bps | IEC61000-4-8: Level 5 |
| Technical Parameters | |
| Case diameter | 64mm |
| Scale range | 0 ~ 2bar abs.(customizable) |
| Accuracy of indication | ±1.5%FS (+20±1°C);±2.5%FS(-20°℃~ +60°C)(gas) |
| Degree of protection | IP65 |
| Ambient condition | -20℃~ +60℃ realative humidity ≤ 95% |
| Leakage rate | ≤ 1 × 10-9 Pa·m³/s (Helium leakage inspection) |
| Process connection | M20 x 1.5 (customizable) |
| Installation mode | Radial or axial |
| Electrical connection | Pluggable connector, wire diameter 1 ~ 2.5 mm²(1.5mm² recommended) |
| Insulation property(contact part) | Insulation resistance: >100MΩ (DC500V)withstand voltage: 2kV, 50/60Hz, 1min |
| Contact type | Magnetic snap-action contact(Up to 3 set of contacts.s ,NO & NC) |
| Impact rating | 30g |
| Contact electrical parameters | Rated Power: 30VAMax switching voltage: 380VMax switching current: 1A |
| Weight | ≈0.9kg |
| Pressure element | Bourdon tube |
Dimensions
Description
ZMJ60V Density Monitors are used to monitor the density of SF₆ gas in sealed tanks, and can be widely used in medium voltage switchgear, RMU. It's suitable for outdoor harsh conditions.
It can provide multiple solutions to support new substations and the renovation and upgrading of existing substations.
The electrical maintenance personnel can make SF gas density monitor calibration or gas filling without disassembling SF6 density monitor.
Features
Compact design, customized installation interface, convenient and reliable.
Process connection customizable in accordance with customer's demands.
Up to three sets of switching contacts can be provided according to user's needs.
Without disassembling SF6 density monitor, SF6 gas density monitor can be calibrated or replaced.
Without disassembling the screws, a person can operate independently, which is convenient.
Temperature compensation for higher accuracy.
It can facilitate on-site personnel to measure micro-water and supplement air for switch.
Avoid the sealing surface and sealing joint damage caused by the disassembling.
Application
SF6 Gas Insulated RMU
SF Gas Insulated Switchgear
Options
Different measuring ranges
Wide temperature range: - 4 0 ^ { \circ } \mathsf { C } \mathsf { t o } + 6 0 ^ { \circ } \mathsf { C }
Measuring Medium: SF \bar { \bar { * } } _ { 6 } , \mathsf { A i r } , \mathsf { N } _ { 2 } , \mathsf { S F } _ { 6 } { + } \mathsf { N } _ { 2 } and other gases
Remote transmission function
Optional measurement accuracy: ±1.0%FS (+20± 1°C) , ±2.5%FS (-20°℃~ +60°C)(gas phase)
| Technical Parameters | |
| Case diameter | Φ64mm |
| Case material | Stainless steel |
| Scale range | 0 to 2bar abs. (customizable) |
| Accuracy | ±1.5%FS (+20℃ ±1℃)±2.5%FS (-20°℃~ +60°C) (gas phase) |
| Ambient conditions | $- 2 0 ^ { \circ } \mathsf { C } \mathsf { t o } 6 0 ^ { \circ } \mathsf { C } ,$ relative humidity ≤ 95%RH |
| Degree of protection | IP65 |
| Leakage rate | $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P a }$ ·m³/s (Helium leakage inspection) |
| Contact type | Magnetic snap-action contacts (up to 3 sets, NO or NC) |
| Process connection | M20×1.5 (customizable) |
| Maintenance connection | M16×1.5 (customized and additional adapter needed tothe calibrator or gas tank) |
| Installation method | Radial or Axial |
| Insulation properties | Insulation resistance: >100 MΩ (500 V DC)Withstand voltage: 2kV, 50/60 Hz 1 min |
| Contact electrical parameters | Rated Power: 30VA |
| Max. operating voltage | 380V |
| Max.current | 1A |
| Weight | ≈0.6kg |
| Pressure element | Bourdon tubes |
Dimensions
Application
\mathsf { S F } _ { 6 } Gas Insulated Swithchgear (GIS)
■ { \mathsf { S F } } _ { 6 } Insulated Circuit Breaker
■ { \mathsf { S F } } _ { 6 } Insulated Pole-Mounted Switch
■ { \mathsf { S F } } _ { 6 } Insulated Transformer
■ { \mathsf { S F } } _ { 6 } Insulation Current Transformer or Voltage Transformer
■ { \mathsf { S F } } _ { 6 } Insulated Bus System
Description
DDM60R Digital Density Monitor are used to monitor the density of { \mathsf { S F } } _ { 6 } gas in sealed tanks. It has real-time remote transmission of { \mathsf { S F } } _ { 6 } gas density change data, realizes online remote monitoring function, and can display the gas density digitally on site. When the density value reaches the set value, the contact output alarm signal. Suitable for medium voltage system monitoring. It can be used in the new substation building and the renovation and upgrading of existing substation.
Features
Local digital display and control.
The microswitch is used as the signal output device to realize the free switching between normally open and normally closed points.
Temperature Compensated.
The alarm value can be set on site and can be applied to cabinets with different alarm values.
Small size, installation interface can be customized, convenient and reliable.
RS485 bus interface, easy to do the system expansion, and to achieve telemetry, remote control functions. Strong EMC capability.
Options
Measuring Medium: SF6, Air, \mathsf { N } _ { 2 } , { \mathsf { S F } } _ { 6 } { + } { \mathsf { N } } _ { 2 } and other gases
Remote part of the main electrical performance indicators and specifications
| Operating voltage | 10~30VDC | IEC61000-4-8: Level 5 | IEC61000-4-2: Level 4 IEC61000-4-3: Level 3 IEC61000-4-5: Level 4 IEC61000-4-6: Level 3 |
| Power consumption | <1W(max. 1.5W) | IEC61000-4-4: Level 4 | |
| Communication mode | RS485 | EMC Class | |
| Communication protocol | Modbus RTU | ||
| Baud Rate | 9600bps | IEC61000-4-9: Level 5 IEC61000-4-10: Level 5 |
| Technical parameters | |
| Scale range | -0.1~0.9MPa |
| Accuracy of transmitter | Pressure: ±0.5%FSTemperature: ±1CPressure at 20℃: ±1.0%FS |
| Degree of protection | IP65 |
| Ambient conditions | $- 4 0 ^ { \circ } C \sim + 7 0 ^ { \circ } C$ , relative humidity: ≤ 95%RH |
| Leakage rate | ≤ 1 × 109 Pa·m³/s (Helium leakage inspection) |
| Process connection | M20×1.5 (customizable) |
| Installation method | Radial or Axial |
| Electrical connection | Preset cable |
| Insulation property(contact part) | Insulation resistance: >100MΩ (DC500V)Power frequency withstand voltage: 2kV, 50/60Hz, 1min |
| Contact type | Magnetic holding electronic relay |
| Impact rating | 30g |
| Contact electrical parameters | Maximum switching voltage: 380VAC/240VDCMaximum switching current: 5A |
| Watch glass | Laminated safety glass |
| Weight | 0.3kg |
Dimensions
Description
DT26 Density Transmitters are used to monitor { \mathsf { S F } } _ { 6 } gas density in sealed tanks. It can provide multiple solutions to support new substations and the renovation and upgrading of existing substations.
Features
■ { \mathsf { S F } } _ { 6 } gas remote density transmitter suitable for medium and high pressure system monitoring.
All welded sensor structure, long - term stable sealing performance.
RS485 bus communication (MODBUS RTU) .
The EMC characteristics of the transmitter meet the requirements of IEC 61000-4-2 to IEC 61000-4-6 standards.
Compact design.
Application
■ { \mathsf { S F } } _ { 6 } Gas Insulated Switchgear (GIS)
■ { \mathsf { S F } } _ { 6 } Insulated Circuit Breakers
■ { \mathsf { S F } } _ { 6 } Insulated Pole-Mounted Switch
■ { \mathsf { S F } } _ { 6 } Insulated Transformer
SF6 Insulated Current Transformer or Voltage Transformer
SF6 Gas Insulated Busbar Systems
■ { \mathsf { S F } } _ { 6 } Insulated Inflatable Cabinet
■ { \mathsf { S F } } _ { 6 } Insulated RMU
Options
| Technical Parameters | |
| Measuring range | 0 to 1.0MPa abs.or 0 to 0.2MPa abs.(customized) |
| Temperature measurement range | $- 4 0 ^ { \circ } \mathsf { C } \sim + 8 0 ^ { \circ } \mathsf { C }$ |
| Pressure measurement accuracy | ±0.5% FS |
| Temperature measurement accuracy | ±1℃ |
| Density (P20) measurement accuracy | ±1.0%FS |
| Degree of protection | IP65 |
| Ambient conditions | $- 4 0 ^ { \circ } \mathsf { C } \mathsf { t o } 7 0 ^ { \circ } \mathsf { C } ,$ relative humidity ≤ 95%RH |
| Leakage rate | $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P a } { \cdot } \mathsf { m } ^ { 3 } / \mathsf { s }$ (Helium leakage inspection) |
| Electrical connection | Hirschmann Connector |
| Weight | 0.2kg |
| Technical Parameters for Remote Module | |||
| Power supply | 24V DC | EMC tests | IEC61000-4-2:level 4IEC61000-4-3:level 3IEC61000-4-4:level 4 |
| Power consumption | < 0.5W | ||
| Communication mode | RS485 | ||
| Protocol | ModBus RTU | IEC61000-4-5:level 4 | |
| Baud rate | 9600bps | ||
| IEC61000-4-6:level 3 | |||
Dimensions
DT10 Density Transmitter
Description
DT10 Density Transmitters are used to monitor SF₆ gas density in sealed tanks. It can provide multiple solutions to support new substations and the renovation and upgrading of existing substations.
Features
Suitable for medium or high volatage systems.
All welded sensor structure, long-term stable sealing performance .
Strong EMC capability.
RS485 bus interface (Modbus RTU).
Application
■ { \mathsf { S F } } _ { 6 } Gas Insulated Swithchgear (GIS)
■ { \mathsf { S F } } _ { 6 } Insulated Circuit Breaker
■ { \mathsf { S F } } _ { 6 } Insulated Pole-Mounted Switch
■ { \mathsf { S F } } _ { 6 } Insulated Transformer
■ { \mathsf { S F } } _ { 6 } Insulation Current Transformer or Voltage Transformer
SF6Insulated Bus System
Options
Measuring Medium: SF6, Air, \mathsf { N } _ { 2 } , { \mathsf { S F } } _ { 6 } + \mathsf { N } _ { 2 } and other gases
| Technical parameters | |
| Measuring range | 0~1.0MPa |
| Accuracy of transmitter | Temperature: ±1CPressure: ±0.5%FSPressure at 20℃: ±1.0%FS |
| Degree of protection | IP65 |
| Ambient Condition | $\cdot 4 0 ^ { \circ } \mathsf { C } \sim + 7 0 ^ { \circ } \mathsf { C }$ , Relative humidity ≤ 95%RH |
| Leakage rate | $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P a } { \cdot } \mathsf { m } ^ { 3 } / \mathsf { s }$ (Helium leakage inspection) |
| Process connection | M20 x 1.5 (customizable) |
| Electrical connection | M12 x 1 Circular connector |
| Weight | 0.1kg |
| Technical Parameters for Remote Module | |||
| Operating voltage | 10~30VDC | EMC tests | IEC61000-4-2: level 4(15kV) IEC61000-4-3: Level 3 (10V/m) |
| Power consumption | <0.5W | IEC61000-4-4: Level 4 (4kV) | |
| Communication mode | RS485 | IEC61000-4-5: level 3 (1kV /2kV) IEC61000-4-8: level 5 (100A/m) | |
| Communication protocol | Modbus RTU | IEC61000-4-9: level 5 (1000A/m) | |
| Baud rate | 9600bps | IEC61000-4-10: level 4 Class (30A/m) | |
Dimensions
Description
The RD40 density transmitter is used to monitor the temperature, pressure and density of the gas in sealed tanks, and the functional parameters meet the requirements of the National Grid.
"QGDW123554-2023 Smart substation technical specification Part 4: Digital remote transmission meter" standard. It can be used in the new substation and the renovation and upgrading of existing substation.
Features
All welded sensor structure, long-term stable sealing performance.
RS485 bus interface, easy to do the system expansion.
Meet the requirements of "QGDW123554-2023 Smart substation technical specification Part 4: Digital remote transmission meter".
Compact and beautiful design.
Application
■ { \mathsf { S F } } _ { 6 } Gas Insulated Swithchgear (GIS)
■ { \mathsf { S F } } _ { 6 } Insulated Circuit Breaker
█ { \mathsf { S F } } _ { 6 } Insulated Pole-Mounted Switch
■ { \mathsf { S F } } _ { 6 } Insulated Transformer
{ \mathsf { S F } } _ { 6 } Insulation Current Transformer or Voltage Transformer
{ \mathsf { S F } } _ { 6 } Insulated Bus System
Options
| Technical Parameters | |
| Measuring range | -0.1~0.9MPa |
| Accuracy of transmitter | Pressure: ±0.5%FSTemperature: ±1CPressure at 20℃: ±1.0%FS |
| Degree of protection | IP65 |
| Ambient condition | $\cdot 4 0 ^ { \circ } \mathsf { C } \sim + 7 0 ^ { \circ } \mathsf { C }$ , relative humidity: ≤ 95%RH |
| Leakage rate | $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P a } { \cdot } \mathsf { m } ^ { 3 } / \mathsf { s }$ (Helium leakage inspection) |
| Process connection | M20 x 1.5 (customizable) |
| Electrical connection | Hersman connector |
| Impact Rating | 50g |
| Weight | 0.4kg |
| Technical Parameters for Remote Module | |||
| Operating voltage | 10~30VDC | IEC61000-4-2: Level 4 | |
| Power consumption | <0.5W | IEC61000-4-3: Level 3IEC61000-4-4: Level 4IEC61000-4-5: Level 4IEC61000-4-6: Level 3IEC61000-4-8: Level 5 | |
| Communication mode | RS485 | EMC tests | |
| Communication protocol | Modbus RTU | ||
| Baud Rate | 9600bps | ||
| IEC61000-4-9: Level 5IEC61000-4-10: Level 5 | |||
Dimensions
Application Range
{ \mathsf { S F } } _ { 6 } Gas Insulated Swithchgear (GIS)
SFInsulated Circuit Breaker
SF6Insulated Pole-Mounted Switch
SF6Insulated Transformer
SF Insulation Current Transformer or Voltage Transformer
SF6Insulated Bus System
Description
RDH40 Gas Density and Dewpoint Transmitter is mainly used to monitor the temperature, pressure, density and moisture content of { \mathsf { S F } } _ { 6 } gas in closed containers, with real-time remote monitoring function. The intelligent compensation technology is used inside the product, which can track the nonlinear change of { \mathsf { S F } } _ { 6 } gas pressure and the change of micro-water content in real time, and the measurement is accurate and widely used. Suitable for monitoring of medium and high voltage systems. It can be used in the new substation building and the renovation and smart upgrading of existing substation.
Features
Suitable for medium or high volatage systems.
Multi-parameter instrument for simultaneous monitoring of gas dew point, density, pressure and temperature with excellent accuracy.
RS485 bus interface (Modbus RTU).
Small size, beautiful structure.
Optional features
Measuring Medium: { \mathsf { S F } } _ { 6 } , Air, \mathsf { N } _ { 2 } , { \mathsf { S F } } _ { 6 } { + } { \mathsf { N } } _ { 2 } and other gases
Remote part of the main electrical performance indicators and specifications
| Operating voltage | 10~30VDC | IEC61000-4-2: Level 4IEC61000-4-3: Level 3IEC61000-4-4: Level 4IEC61000-4-5: Level 4EMC Class IEC61000-4-6: Level 3IEC61000-4-8: Level 5IEC61000-4-9: Level 5IEC61000-4-10: Level 5 |
| Power consumption | <0.5W | |
| Communication mode | RS485 | |
| Communication protocol | Modbus RTU | |
| Baud rate | 9600bps | |
| Technical parameters | ||
| Pressure measuring range | 0 ~ 1.4MPa(customizable) | |
| Dew measuring range | $- 5 0 ^ { \circ } \mathsf { C } \sim + 2 0 ^ { \circ } \mathsf { C }$ | |
| Accuracy of transmitter | Temperature: ±1℃ Pressure: ±0.5%FSPressure at $2 0 ^ { \circ } \mathsf { C } \colon \pm 1 . 0 \% \mathsf { F S }$ Dew: ±3℃ | |
| Degree of protection | IP65 | |
| Ambient condition | $- 4 0 ^ { \circ } \mathsf { C } \sim + 8 0 ^ { \circ } \mathsf { C }$ , Relative humidity ≤ 95%RH | |
| Leakage rate | $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P a } \cdot \mathsf { m } ^ { 3 } / \mathsf { s }$ (Helium leakage inspection) | |
| Process connection | G1 (customizable) | |
| Electrical connection | M12 x 1 Circular connector | |
| Weight | 0.4kg | |
Dimensions
Description
MDK40 Density Switches are used to monitor the density of SF₆ gas in sealed tanks, and can be widely used in medium voltage switchgear and RMU. They're suitable for outdoor harsh environments.
They can provide multiple solutions to support new substations and the renovation and smart upgrading of existing substations.
Features
Temperature compensation ensures higher set point accuracy.
Can provide up to three sets of microswitch contacts allowing instant and accurate switching.
High shock resistance.
Normally closed contacts will not set a false alarm due to vibration.
Application
■ { \mathsf { S F } } _ { 6 } Gas Insulated RMU
{ \mathsf { S F } } _ { 6 } Gas Insulated Switchgear
Options
Different measuring ranges
Wide temperature range
Measuring medium: S F _ { 6 } 、 \mathsf { A i r } , N _ { 2 } 、 5 F _ { 6 } + N _ { 2 } and other gases
| Technical Parameters | |
| Measuring range | 0 ~3 bar abs. (customizable) |
| Accuracy of set point | $\pm 2 . 0 \% \textcircled { \varpi } - 3 0 \textcircled { \times } + 5 0 \textcircled { \times }$ |
| Degree of protection | IP42 |
| Ambient conditions | $- 2 5 ^ { \circ } \mathsf { C } \sim + 6 0 ^ { \circ } \mathsf { C }$ , relative humidity ≤ 95%RH |
| Leakage rate | ≤ 1x 10{Pa ·m³/s(helium leakage inspection) |
| Process connection | G1/4 (customizable) |
| Installation method | Axial |
| Electrical connection | Plug-in connection cable size: 0.2mm² to 2.5mm² |
| Insulation properties | Insulation resistance: >100 MΩ (DC 500V)Withstand voltage: 2kV, 50/60 Hz,1min |
| Contact type | Mirco switch |
| Impact rating | 30g |
| Contact electrical parameters | 30W/50VA, 1A (upper limit)220VDC/380V 50/60Hz (upper limit) |
| Weight | 0.3kg |
| Pressure element | Bellow |
Dimensions
Application
■ { \mathsf { S F } } _ { 6 } Gas Insulated Switchgear (GIS)
■ { \mathsf { S F } } _ { 6 } Insulated Circuit Breakers
{ \mathsf { S F } } _ { 6 } Insulated Pole-mounted Switch
■ { \mathsf { S F } } _ { 6 } Insulated Transformer
\mathsf { \widehat S } \mathsf { F } _ { 6 } Insulated Current Transformer or Voltage Transformer
{ \mathsf { S F } } _ { 6 } Gas Insulated Busbar Systems
{ \mathsf { S F } } _ { 6 } Insulated Inflatable Cabinet
{ \mathsf { S F } } _ { 6 } Insulated RMU
Description
The CV Self-Sealing Valve is a device connecting { \mathsf { S F } } _ { 6 } gas density meter or density monitor and { \mathsf { S F } } _ { 6 } gas chamber; after the completion of the assembly, { \mathsf { S F } } _ { 6 } gas chamber can be effectively sealed. It can be applied to high and medium voltage equipment.
Features
Self-sealing: when this valve is disconnected from either side,it can seal and stop the flow of gas.
Can withstand repeated usage.
Can be used on outdoor switchgear.
Can connect { \mathsf { S F } } _ { 6 } gas filling and vacuum pumping devices.
Can connect { \mathsf { S F } } _ { 6 } gas recovery truck.
Options
Pressure connections: customizable
Nominal diameter: customizable
Technical Parameters
| Valve material | stainless steel, aluminum or a copper alloy |
| Nominal bore | DN6、DN8、DN12、DN20 etc |
| Surface finish | Aluminum: Oxidation treatmentStainless steel, copper alloys: Not processed |
| Ambient conditions | $- 4 0 ^ { \circ } \mathsf { C } \mathsf { t o } 6 0 ^ { \circ } \mathsf { C }$ |
| Leakage rate | $\leqslant 1 { \times } 1 0 ^ { - 9 } \mathsf { P } \mathsf { a } \cdot \mathsf { m } ^ { 3 } / \mathsf { s }$ |
Application
■ { \mathsf { S F } } _ { 6 } Gas Insulated Switchgear (GIS)
■ { \mathsf { S F } } _ { 6 } Insulated Circuit Breaker
{ \mathsf { S F } } _ { 6 } Insulated Pole-Mounted Switch
{ \mathsf { S F } } _ { 6 } Insulated Transformer
{ \mathsf { S F } } _ { 6 } Insulated Current Transformers or Voltage Transformers
SF6 Insulated Bus System
Description
The FMZ Connection Valves is a connecting device of { \mathsf { S F } } _ { 6 } density monitor to SF6 switch gear. The maintenance personnel can inspect { \mathsf { S F } } _ { 6 } density monitor or replace jt without disassembling the device from installed switchgear. It provides a solution to gas density monitor inspection, replacement and gas filling, without damage to the sealing surface and seal rings of the switch caused by disassembling of valves in the process of regular checks. Therefore, it can reduce the leakage rate, improve the work efficiency, and ensure the safe operation of SF₆ electrical switch.
Features
The { \mathsf { S F } } _ { 6 } density meters can be inspected/replaced without disassembling the SF6meter/monitor.
Operation can be done by one person alone without removing screws, convenient, labor – saving and time-saving.
Easy for personnel on site to make micro-water detection and gas filling.
Avoid the damage to sealing surface and seal rings due to disassembling.
High-quality stainless steel with good looking appearance, never get rusted.
With stainless steel rain cover, it can resist rain and sun, greatly improving the reliability and service life of the density relay.
Options
Pressure connections: customizable
Nominal diameter: customizable
Valve type: needle valve or ball valve
| Technical Parameters | |
| Valve Material | Aluminium /Copper alloy/ Stainless steel |
| Nominal bore | DN6、DN8、DN12、DN20 etc |
| Surface Finish | Aluminium - anodized Copper alloy – naturalAISI304 stainless steel-natural |
| Ambient conditions | -40° C to +70° C |
| Leakage rate | Needle valve: $\leqslant 1 \times 1 0 ^ { - 8 } \mathsf { P a } \cdot \mathsf { m } ^ { 3 } / \mathsf { s }$ Ball valve: $\leqslant 1 \times 1 0 ^ { - 9 } \mathsf { P } \mathsf { a } \cdot \mathsf { m } ^ { 3 } / \mathsf { s }$ |
| Operating pressure range | 0~1.6MPa |
| Maximum withstand pressure | 6.4MPa |
Description
The VDA-03 Gas Density Monitor Calibrator is an intelligent, fully automatic calibration instrument that uses advanced embedded microprocessors to test the performance of Gas Density Monitors for { \sf S F } _ { 6 } , { \sf S F } _ { 6 } / { \sf N } _ { 2 } hybrid and { \sf S F } _ { 6 } / { \sf C F } _ { 4 } hybrid gases. The device has two working modes: zero-pressure mode and working pressure modes. Working pressure calibration mode tests the accuracy of GDM from the rated filling pressure to zero, while zero pressure mode starts from zero and rises to the rated pressure. This portable calibration instrument provides great convenience for the operation, testing, calibration and maintenance of electrical products.
Features
Configuration
Calibrator: 1 Unit
Essential accessories: 1 self-sealing connection tube; 1 calibration point sampling line; 1 temperature sensor; 1 external gas cylinder & connecting tubes; 1 power cord; 1 production inspection record & 1 user manual.
Optional accessories: 1 toolbox (including a complete set of adaptors)
| Technical parameters | |
| Power supply | Internal rechargeable lithium battery or external 220VAC |
| Measuring range | Pressure calibration range 0~1Mpa;Temperature measurement range -40°C ~+100°C |
| Accuracy | 0.1 grade |
| Resolution | Pressure display resolution 0.0001Mpa; Temperaturedisplay resolution 0.1°C |
| Density monitor contact calibration | Single signal (single alarm, single lockout), single alarmand single lockout, single alarm and double lockout |
| Full calibration time ≤ 5min | |
JXQ Series RS485 Hub
Description
JXQ series RS485 hub is a RS-485 bus splitter designed to address the requirements of large RS-485 systems in complex electromagnetic environments. The product supports transmission rates up to 115.2Kbps. To ensure safe and reliable data communication, the RS-485 interface uses optical isolation technology to prevent lightning surges from introducing into the converter and equipment. The built-in optical isolator and 1500W surge protection circuit provide 2500V isolation voltage and effectively prevent lightning, ESD, and grounding interference. The power supply uses an external switching power supply for reliable operation. In the RS-485 mode of operation, the discrimination circuit automatically senses the direction of data flow and switches the enable control circuit automatically, solving the delay problem of RS-485 transceiver conversion easily. It is widely used in power collection systems and is a high-performance and cost-effective data interface conversion product.
JXQ series RS-485 HUB provides star-type RS-485 bus connection. Each port has short circuit and open circuit protection. Optical isolation of 2500V allows users to easily improve the RS-485 bus structure, divide network segments, and improve communication reliability. When lightning or equipment failure occurs, the problematic network segment will be isolated to ensure the normal operation of other network segments. This performance greatly improves the reliability of the existing RS-485 network and effectively reduces maintenance time of the network.
Application
Features
Each port has short circuit and open circuit protection, and any interface failure will not affect the normal operation of other interfaces.
| Technical parameter | |
| Interface characteristics | The interface is compatible with EIA/TIA's RS-232Cand RS-485 standards |
| Operating voltage | DC 12-48V with a current of 350mA |
| Transmission medium | twisted pair or shielded wire |
| Operating mode | asynchronous half-duplex |
| Signal display | Eleven signal indicators including power (PWR), transmit(TX), receive (RX), and fault (E1-E8) indicators |
| Interface protection | Using optical isolation |
| Transmission rate | 300bps-115.2kbps |
| Size | 145mmx90mmx40mm |
| Operating environment | Temperature: -40℃ ~+85°C , relative humidity: 5%~95% |
| Installation method | Rail installation |
Options
| Model Instruction | Installation Operate power | ||
| JXQ-RS-08 | Eight RS485 ports | Rail installation | 12~48VDC |
| JXQ-RS-04 | Four RS485 ports | Rail installation | 12~48VDC |
Dimensions
DA Series Digital meter monitoring terminal
Application
Online Monitoring of Digital Meters
Description
DA-type digital meter monitoring terminal is a communication management machine product based on embedded hardware. The system adopts Linux operating system and is stable, reliable, and easy to use. It adopts a highly integrated new generation of 32-bit computer internally, and can be integrated with our company's dedicated communication management software. It can be used to collect information from the entire field of power distribution automation system and send it to the local background or remote dispatching master station, and at the same time, it will pass the command of the background or master station to each measurement and control device to achieve local or remote control.
DA-type digital meter monitoring terminals can directly collect data from all devices in the automation system, supporting over 100 protocols, such as Modbus, IEC101, IEC103, IEC104, IEC61850, CSC2000, DL645, etc., and send them to the monitoring background through the user-specified communication protocol (101, 104, Modbus, CDT, etc.) and communication medium (ethernet, fiber optics, etc.), completing the background monitoring of the entire site.
Features
Support Modbus, IEC101, IEC103, IEC104, CSC2000, DL645 and other up to 100 protocol conversion, fully support IEC61850 standard.
■Support the State Grid "Smart Substation Technical specification Part 4: Digital remote meter" meter access.
Support multi-channel adaptive industrial 10/100M Ethernet, 2/4 optional; Multiple RS485 ports, 4/8/16 optional.
Support one single mode and one multi-mode fiber output.
Support a variety of voltage access, a variety of installation methods.
Support data storage, block logic programming.
The RS485 port uses optoelectronic isolator.
| Technical parameters | |
| Ambient condition | -40℃~+85℃ |
| Operating voltage | 220VAC/220VDC (some series use DC24V power supply) |
| Power consumption | <15W |
| Model | Instruction Installation | Operate power | |
| DA8240 | Two 10M/100M Ethernet ports and four RS485 ports | Flat mounting | 9~24VDC |
| DA8600-8-D | Four 10M/100M Ethernet ports and eight RS485 ports | Flat mounting | 12~24VDC |
| DA8600-8 | Four 10M/100M Ethernet ports and eight RS485 ports | 1U rack mounting | 85~230VDC/VAC |
| DA8600-16 | Four 10M/100M Ethernet ports and sixteen RS485 ports | 1U rack mounting | 85~230VDC/VAC |
| DA8600-8-F | Two 10M/100M Ethernet ports, eight RS485 ports,One single-mode Fibre Channel port and one multi-modeFibre Channel port | 1U rack mounting | 85~230VDC/VAC |
Dimensions
The well-designed high-frequency, low-current, high-voltage switching power supply is applied to the { \mathsf { S F } } _ { 6 } sensor monitoring head, which is characterized by safety, reliability, and high efficiency. Take full advantage of the flexibility of the microcontroller.
85V\~265V \mathsf { A C } , to meet the different field environment needs
Large-screen LCD color display, beautiful and generous, running status at a glance. Simple operation interface, simple operation.
The large-capacity memory supported by the system host can store historical data for more than one year. The excellent performance of the query system software ensures that the system can quickly query historical data in seconds.
Description
The { \mathsf { S F } } _ { 6 } gas leakage quantitative alarm system is based on the current situation in which the power system emphasizes safe production, and is an intelligent online detection system designed and developed to provide personal health and safety protection for the personnel in the power distribution device room where { \mathsf { S F } } _ { 6 } equipment is installed.
The system mainly detects the { \mathsf { S F } } _ { 6 } gas content and oxygen content in the ambient air. When the SF6 gas content in the environment exceeds the standard or lacks oxygen, it can alarm in real time. At the same time, the ventilation system is automatically turned { \mathsf { O n } } , with temperature and humidity detection, working status voice prompts, remote alarm, Historical data query and many other rich features.
Features
The use of high-sensitivity imported sensors, long 一 { { i f } } { e } , with false alarm filtering software, to avoid false alarms.
The micro-monitoring technology can send out early on-site warnings and indicate the locations of gas leaks, promptly notify personnel in hazardous locations to evacuate, find and eliminate sources of leakage, and protect operating equipment.
A cable connects the { \sf S F } _ { 6 } / \sf { O } _ { 2 } transmitter, infrared, main unit, and fan controller, and can be discretely combined to achieve high field adaptability.
Multi-point monitoring at the same time meets the needs of the site environment and improves monitoring reliability.
The data can be transmitted far to the telecontrol control center via the RS485 or RS232 bus. The control center can also directly inquire and control the monitoring system.
Configuration
SF6 quantitative leak monitoring alarm system host.
Accessories: { \sf S F } _ { 6 } / \sf { O } _ { 2 } double gas transmitter (on-demand), 1 fan controller, 1 warning light, and cable (several).
| Technical indicators | |
| SF6 gas concentration alarm range | 50~2000PPM(alarm point can be set up, the state regulations 1000PPM) |
| SF6 gas detection sensitivity | ±5% setting |
| Oxygen concentration alarm point | 18% |
| Oxygen measurement accuracy | <0.4% |
| Temperature display range | -50~99°C |
| Humidity display range | 0 to 99% RH |
| Input power | 85〜265VAC |
| Alarm output point power supply | 2A |
| Fan output contact power supply | 16A |
| Fan ventilation time setting | 15MIN/time or user set arbitrarily |
| Data recording capacity | 10000 entries |
| Communication | RS-485 standard protocol |
Product Overview
SF₆ (Sulfur Hexafluoride) gas is widely used as an excellent insulating and arc-suppressing medium in medium and high voltage, as well as in high voltage switchgear and GIS. The density index of { \mathsf { S F } } _ { 6 } gas is crucial to its insulation and arc-suppressing performance.
SF6 Gas State Monitor and Receiver (LS-WC and LS-WT series) are self-developed monitoring products by our company. The monitor can adapt to our full range of transmitters and remote density relays, monitoring SF₆ gas pressure, temperature, density, and moisture content in real time. The data is transmitted back to the background system in real time through wireless LoRa data transmission. The background system can perform online monitoring and analysis, and achieve functions such as real-time data query, historical data statistics, pre-set alarm reminders, and data curve query for all data. This system is mainly designed for real-time monitoring of critical equipment such as SF₆ gas insulated switchgear, GIS, transformers, and mutual inductors in various high-voltage electrical devices.
The monitor is powered by a battery and transmits data wirelessly, without the need for cables on site. The transmitters and remote density relays can be powered by the monitor, without the need for separate power supply on site.
Applications
■ { \mathsf { S F } } _ { 6 } Insulated Combination Apparatus (GIS)
■ { \mathsf { S F } } _ { 6 } Insulated Circuit Breaker
■ { \mathsf { S F } } _ { 6 } Insulated On-site Switch
■ { \mathsf { S F } } _ { 6 } Insulated Transformer
SF6Insulated Mutual Inductor
SF6Insulated Busbar System
Options
The receiver has an RS485 MODBUS RTU output or a network port TCP/IP output.
It comes with a background software package.
The receiver can be equipped with an instrument cabinet.
Features
The monitor and receiver have user-friendly human-machine interfaces, facilitating field debugging and testing.
The monitor can adapt to our full range of transmitters and remote density relays (with a accuracy of full scale 1.0), which can be configured according to customer needs with different functions, ranges, and interface sizes.
It is suitable for both indoor and outdoor installations.
The battery uses a large capacity lithium battery, with a service life of over 10 years (related to the data collection period).
The receiver has data storage function; it can store data for over 10 years.
The background software has data storage, query, and statistical analysis functions.
It has a RS485 bus interface that can upload pressure, temperature, and density data in real time.
It has 470MHz and 2.4GHz optional frequencies for wireless transmission.
| Technical Parameters | ||
| Monitor | Button | Membrane keypad, with a life of 2 million presses at a forceof 300gf Keypad |
| Screen | Resolution: 128x64 Dot; Viewing size: 54.2x32.5mm;Supply voltage: 3.3V; Supply current: 45mA | |
| Battery | Type: Lithium thionyl chloride battery;Nominal capacity: 19AH; Voltage: 3.6V | |
| Transmitter interface | Power supply: 12V@20mA; Communication: RS485 rotocol;Private protocol can be customized | |
| Standby current | <10uA | |
| Protection grade | IP65 | |
| Operating temperature | $- 4 0 ^ { \circ } \mathsf { C } \sim + 7 0 ^ { \circ } \mathsf { C }$ | |
| Installation method | Metal zip tie installation | |
| Receiver | Screen | Resistive touch 7-inch LCD screen;Resolution: 1024*600 |
| Power supply | 12V DC @1A (manufacturer can provide 220Vac adapter) | |
| Signal interface | Double RS485 interface, two interfaces can use differentcommunication protocols; RJ45 interface: 10M/100M;USB interface: 2.0 | |
| Other hardware | 16G SD card | |
| Antenna | Suction cup antenna; Feeder line: 2m (2m~20m) | |
| Installation method | Wall mounted installation | |
Dimensions
Monitor: 144 × 88.5 × 66.5mm Receiver: 226 × 162 × 40mm Instrument box: 330 × 235 × 68mm
TRUSTED PARTNERS
MISSION UNIFYING THE POWER OF DIGITAL INTELLIGENCE, CONTRIBUTING TO THE ESTABLISHMENT OF INNOVATIVE POWER SYSTEM
VISION TO BE A GLOBAL LEADER IN DIGITAL AND INTELLIGENT ELECTRICAL INSTRUMENTS
VALUES
INTEGRITY & PRAGMATISM,INNOVATION &COOPERATION, STRIVING FOR EXCELLENCE,SERVING CUSTOMERS