TEL: +86 - 21 - 5442 0482 FAX: +86 - 21 - 5442 1043
ADD: NO.50,LANE 3679,JINDU ROAD,
XINZHUANG INDUSTRIALZONE,SHANGHAI,P.R.CHINA
INSULATED GAS
MONITORING SERIES
MEDIUM VOLTAGE
LANSO KONLY (SHANGHAI)INSTRUMENTS CO.,LTD.
WWW.LANSOINSTRUMENTS.COM
LANSO KONLY (SHANGHAI) INSTRUMENTS CO.,LTD.
In technology and market development, Lanso Instruments relies on its independent R&D innovation platform and
holds multiple technical invention patents. With technological breakthroughs in segmented fields, the company has
been awarded a number of authoritative qualifications, including the Little Giant Enterprise, National Key \"Little Giant\"
Enterprise, ���� Shanghai Manufacturing Single Champion and Shanghai Green Factory. Our products have been
exported to more than �� countries worldwide, covering France, Germany, Italy, Spain, India and other regions.
In globalization strategy, the company has established deep strategic partnerships with international electrical giants
like ABB, HITACHI, Schneider, and Siemens, while maintaining long-term collaborations with leading domestic switchgear companies such as Taikai Group (TK), Sieyuan Electric, Pinggao Electric (PG), and China XD Group etc.
The company always puts quality management at the core of its development. Through scientific and standardized
management systems as well as rigorous and comprehensive management measures, it fully ensures stable product
quality and reliable performance. The company has obtained authoritative certifications from Swiss SGS, including ISO
���� Quality Management System, ISO ����� Environmental Management System, ISO ����� Occupational Health and
Safety Management System, ISO ����� Innovation and Intellectual Property Management System, as well as ISO �����,
ISO ����� and ISO ����� etc. Meanwhile, the enterprise has established a full-chain quality traceability system covering
raw material procurement, production and manufacturing to finished product delivery, enabling whole-process quality
control and full traceability.
The company's product portfolio includes three major series. The insulation gas monitoring series includes various
digital density monitors (density meters), density switches, density transmitters, and valves. The transformer accessories
series mainly includes intelligent buchholz relays, oil temperature indicators, and oil level indicators. The equipment
and instruments series mainly includes gas density relay calibrators.
With outstanding technological strength, strict quality management, and a global strategy, Lanso Instruments is innovation-driven and quality-backed, continuously leading industry development and contributing to the intelligent and
green transformation of the global power industry.
Lanso Konly (Shanghai) Instruments Co., Ltd. is an innovation-driven
and high-tech enterprise. The company is committed to creating
globally leading SF�
and other alternative insulating gas monitoring
solutions and digital transformer accessories series products.
Backed by cutting-edge technology, the company has established a
full-fledged industrial ecosystem spanning R&D, production,
marketing, and technical services, continuously safeguarding the
operation of power equipment worldwide.
CONTENTS
KL50 Pressure Gauge
KL60 Density Meter
KL60R
Remote-Transmission Density Meter
ZMJ60 Density Monitor
ZMJ60R Density Monitor
ZMJ60V Density Monitor
DDM60R Digital Density Monitor
DT26 Density Transmitter
DT10 Density Transmitter
RD40 Density Transmitter
RDH40
SF6 Gas Density and Dew Transmitter
MDK40 Density Switch
CV Self-Sealing Valve
FMZ Connection Valves
VDA-03 Gas Density Monitor Calibrator
JXQ Series RS485 Hub
DA Series
Digital Meter Monitoring Terminal
GLM Type SF6 Gas
Leakage Quantitative Alarm System
SF6 Gas Monitor and Receiver Based on
LoRa Wireless Transmission Technology
02
04
06
08
10
12
14
16
18
20
22
24
26
28
30
32
34
36
38
02 KL50 Pressure Gauge
KL50
Pressure Gauge
Description
KL50 Pressure Gauges are used to monitor the pressure
of the gas in sealed tanks. They are applied to indicate
the relative pressure of the gas on site. They are designed to monitor Medium Voltage systems.
Application Options
SF6 Gas Insulated RMU
SF6 Gas Insulated Switchgear
Pressure connection: customizable
Measuring medium: SF6, Air, N2, SF6 + N2 and other
gases
Wide temperature range: -40℃ to +60℃
Features
Display the relative pressure of the gas in the closed
container at real-time temperature.
Suitable for indoor or outdoor installation.
AISI 304 hermetically sealed stainless steel case.
Gas connection tubes are made of AISI 316 stainless
steel.
03
KL50 pressure gauge sample table 1 size
KL50 pressure gauge sample table 2 size
Ambient conditions
Leakage rate
Process connection
Installation method
Window glass
Weight
-20° C to +60° C,relative humidity ≤ 95%RH
≤ 1 × 10-9 Pa·m3
/s (Helium leakage inspection)
M24 × 1.5 (customizable)
Radial or Axial
Laminated safety glass
0.2kg
Technical Parameters
Case diameter
Scale range
50mm
0 to 0.6 bar
Accuracy ±1.5%FS(+20±1℃)
±2.5%FS(-20℃~ +60℃)(gas phase)
Dimensions
04 KL60 Density Meter
KL60
Density Meter
Description
KL 60 Density Meters are used to monitor SF6 gas density
in sealed tanks. They are applied to indicate gas density.
They are designed to monitor Medium Voltage systems.
Features
Bimetal temperature compensation ensures higher
measurement accuracy.
Suitable for indoor or outdoor installation.
AISI 304 hermetically sealed stainless steel case.
Gas connection tubes are made of AISI 316 stainless
steel.
The on-screen display value and output signals are
independent of the impact of external environment,
such as altitude.
Application Options
SF6 Gas Insulated RMU
SF6 Gas Insulated Switchgear
Process connection: customizable
Measuring Medium: SF6, Air, N2, SF6 + N2 and other
gases
Suitable for High-altitude environment
Wider temperature range: -40℃ to +60℃
Optional measurement accuracy:±1.0%FS(+20±
1℃),±2.5%FS(-20℃~ +60℃)(gas phase)
05
KL60 eccentric sample gauge size
KL60 centerpiece sample gauge size
65
Degree of protection
Ambient conditions
Leakage rate
Process connection
Installation method
Watch glass
Impact rating
Weight
Pressure element
IP65
-20° C to +60° C,relative humidity ≤ 95%RH
≤ 1 × 10-9 Pa·m3
/s (Helium leakage inspection)
M24 × 1.5 (customizable)
Radial or Axial
Laminated safety glass
30g
≈ 0.2kg
Bourdon tubes
Technical Parameters
Case diameter
Scale range
64mm
1 to 2bar abs
Accuracy ±1.5%FS(+20±1℃),
±2.5%FS(-20℃~ +60℃)(gas phase)
Dimensions
06 KL60R Remote-Transmission
Density Meter
KL60R
Remote-Transmission Density Meter
Description
These instruments are used to monitor the density of
SF6 gas in sealed tanks and can be widely used in medium voltage switchgear and RMU.They are applied to
indicate the gas density and reliably output SF6 gas density signal for remote monitoring.
They can provide multiple solutions to support new substations and the intelligent transformation of existing
substations.
Features
Volume minimization,customized installation interface,convenient and reliable.
Pressure interface customized in accordance with
customer’s demands.
Utmost three pairs of switching contacts can be provided according to user’s needs.
The RS485 remote function ensures remote monitoring.
Application Options
SF6 gas Insulated RMU
SF6 gas Insulated Switchgear
Measuring range
Ambient condition
Outlet Direction and cable length
Installation method
Suitable for High-altitude environment
Measurement Medium: SF6, Air, N2, SF6 + N2 and other gases
07
Degree of protection
Ambient conditions
Leakage rate
Process connection
Installation method
Weight
IP65
-40° C to +60° C, relative humidity ≤ 95%RH
≤ 1 × 10-9 Pa·m3/s (Helium leakage inspection)
M24×1.5 (customizable)
radial or axial
0.3kg
Technical Parameters
Case diameter
Scale range
Φ64mm
1.0 to 2bar abs
Accuracy a) At 20° C: Class 1.0 or 1.5
b) -40° C to +60° C: Class 2.5
Dimensions
08 ZMJ60 Density Monitor
ZMJ60
Density Monitor
Description
ZMJ60 Density Monitors are used to monitor the density
of SF6 gas in sealed tanks and can be widely used in medium voltage switchgear and RMU. They’re also suitable
for outdoor harsh conditions.
They can provide multiple solutions to support new substations and the renovation and upgrading of existing
substations.
Features
Compact design, customizable installation interface, convenient and reliable.
Process connection customizable in accordance
with customer's demands.
Up to three sets of switching contacts can be provided according to user’s needs.
Temperature compensation for higher accuracy.
Application Options
SF6 Gas Insulated RMU
SF6 Gas Insulated Switchgear
Different measuring ranges
Wider temperature range: -40℃ to +60℃
Outlet Direction and cable length
Installation method
Suitable for High-altitude environment
Can detect SF6、Air、N2、SF6+N2 and other gases
Optional measurement accuracy:±1.0%FS(+20±
1℃),±2.5%FS(-20℃~ +60℃)(gas phase)
09
Degree of protection
Ambient conditions
Leakage rate
Contact type
Process connection
Installation method
Insulation properties
Contact electrical parameters
Weight
Pressure Element
IP65
-20° C to +60° C, relative humidity ≤ 95%RH
≤ 1 × 10-9 Pa·m3
/s(Helium leakage inspection)
Magnetic snap-action contacts (up to 3 sets, NO or NC)
M20×1.5 (customizable)
Radial or Axial
Insulation resistance: >100 MΩ (500 V DC)
Withstand voltage: 2kV, 50/60 Hz 1 min
Rated Power: 30VA
Max operating voltage: 380V
Max current: 1A
≈ 0.5kg
Bourdon tubes
Technical Parameters
Case diameter
Case material
Scale range
Φ64mm
Stainless steel
0 to 2bar abs. (customizable)
Accuracy ±1.5%FS(+20±1° C)
±2.5%FS(-20° C ~ +60° C)(gas phase)
Dimensions
10 ZMJ60R Density Monitor
ZMJ60R
Density Monitor
Features
Description
ZMJ60R Density Monitors is used to monitor the density
of gas in closed containers, and can be widely used in
medium voltage switchgear and ring network cabinet. It
can display gas density on site, and reliably output SF6
gas density signal for remote monitoring and monitoring. It can be used in the new substation building and
renovation and upgrading of existing substation.
Compact design, customizable installation interface
to user'sneed, convenient and reliable.
Suited for different indoor and outdoor installation
requirements.
Up to three sets of contact switches.
RS485 remote transmission function, convenient remote monitoring.
Temperature compensated.
Technical Parameters for Remote Module
Operating voltage
EMC Class
10~30VDC IEC61000-4-2:Level 4
IEC61000-4-3:Level 3
IEC61000-4-4:Level 4
IEC61000-4-5:Level 3
IEC61000-4-6:Level 3
IEC61000-4-8:Level 5
Power consumption <0.5W
Communication mode RS485
Communication protocol
Baud rate
Modbus RTU
9600bps
Options
Measuring range
Wider temperature range: -40℃ ~ +60℃
Outlet mode and cable length
Installation method
High altitude environment application
Measuring Medium:SF6, Air, N2, SF6+N2 and other
gases
Optional measurement accuracy:±1.0%FS(+20±
1℃),±2.5%FS(-20℃~ +60℃)(gas phase)
Application
SF6 Gas Insulated Ring Main Unit
SF6 Gas Insulated Switch Gear
11
Ambient condition
Degree of protection
Leakage rate
Weight
Process connection
Pressure element
Installation mode
Electrical connection
Insulation property(contact part)
Contact type
Impact rating
Contact electrical parameters
-20℃ ~ +60℃ realative humidity ≤ 95%
IP65
≤ 1 × 10-9 Pa·m3
/s (Helium leakage inspection)
≈ 0.9kg
M20 x 1.5 (customizable)
Bourdon tube
Radial or axial
Pluggable connector, wire diameter 1 ~ 2.5 mm2
(1.5mm2
recommended)
Insulation resistance: >100MΩ (DC500V)
withstand voltage: 2kV, 50/60Hz, 1min
Magnetic snap-action contact
(Up to 3 set of contacts.s ,NO & NC)
30 g
Rated Power:30VA
Max switching voltage:380V
Max switching current:1A
Technical Parameters
Case diameter
Scale range
Accuracy of indication
64mm
0 ~ 2bar abs.(customizable)
±1.5%FS(+20±1℃); ±2.5%FS(-20℃~ +60℃)(gas)
Dimensions
12 ZMJ60V Density Monitor
ZMJ60V
Density Monitor
Description
ZMJ60V Density Monitors are used to monitor the density of SF6 gas in sealed tanks, and can be widely used in
medium voltage switchgear, RMU. It’s suitable for outdoor harsh conditions.
It can provide multiple solutions to support new substations and the renovation and upgrading of existing
substations.
The electrical maintenance personnel can make SF6 gas
density monitor calibration or gas filling without disassembling SF6 density monitor.
Features
Compact design, customized installation interface,
convenient and reliable.
Process connection customizable in accordance
with customer’s demands.
Up to three sets of switching contacts can be provided according to user’s needs.
Without disassembling SF6 density monitor, SF6 gas
density monitor can be calibrated or replaced.
Without disassembling the screws, a person can
operate independently, which is convenient.
Temperature compensation for higher accuracy.
It can facilitate on-site personnel to measure micro-water and supplement air for switch.
Avoid the sealing surface and sealing joint damage
caused by the disassembling.
Application Options
SF6 Gas Insulated RMU
SF6 Gas Insulated Switchgear
Different measuring ranges
Wide temperature range:-40° C to +60° C
Measuring Medium:SF6, Air, N2, SF6+N2 and other
gases
Remote transmission function
Optional measurement accuracy:±1.0%FS(+20±
1℃),±2.5%FS(-20℃~ +60℃)(gas phase)
13
Ambient conditions
Accuracy
Degree of protection
Contact electrical parameters
Leakage rate
Max. operating voltage
Max. current
Weight
Pressure element
Contact type
Process connection
Maintenance connection
Installation method
Insulation properties
-20° C to 60° C, relative humidity ≤ 95%RH
±1.5%FS(+20℃ ±1℃)
±2.5%FS(-20℃~ +60℃)(gas phase)
IP65
Rated Power: 30VA
≤ 1 × 10-9 Pa·m3
/s (Helium leakage inspection)
380V
1A
≈ 0.6kg
Bourdon tubes
Magnetic snap-action contacts (up to 3 sets, NO or NC)
M20×1.5 (customizable)
M16×1.5 (customized and additional adapter needed to
the calibrator or gas tank)
Radial or Axial
Insulation resistance: >100 MΩ (500 V DC)
Withstand voltage: 2kV, 50/60 Hz 1 min
Technical Parameters
Case diameter
Case material
Scale range
Φ64mm
Stainless steel
0 to 2bar abs.(customizable)
Dimensions
O-ring
φ22×3
EPDM
φ64 ±0.5
66±0.5
166±2
14 DDM60R
Digital Density Monitor
DDM60R
Digital Density Monitor
Features
Description
DDM60R Digital Density Monitor are used to monitor the
density of SF6 gas in sealed tanks. It has real-time remote transmission of SF6 gas density change data, realizes online remote monitoring function, and can display
the gas density digitally on site. When the density value
reaches the set value, the contact output alarm signal.
Suitable for medium voltage system monitoring. It can
be used in the new substation building and the renovation and upgrading of existing substation.
Local digital display and control.
The microswitch is used as the signal output device
to realize the free switching between normally open
and normally closed points.
Temperature Compensated.
The alarm value can be set on site and can be applied to cabinets with different alarm values.
Small size, installation interface can be customized,
convenient and reliable.
RS485 bus interface, easy to do the system expansion, and to achieve telemetry, remote control functions. Strong EMC capability.
Remote part of the main electrical performance indicators and specifications
Operating voltage
EMC Class
10~30VDC IEC61000-4-2: Level 4
IEC61000-4-3: Level 3
IEC61000-4-4: Level 4
IEC61000-4-5: Level 4
IEC61000-4-6: Level 3
IEC61000-4-8: Level 5
IEC61000-4-9: Level 5
IEC61000-4-10: Level 5
Power consumption <1W(max. 1.5W)
Communication mode RS485
Communication protocol
Baud Rate
Modbus RTU
9600bps
Options
Measuring Medium: SF6, Air, N2, SF6+N2 and other
gases
Application
SF6 Gas Insulated Swithchgear (GIS)
SF6 Insulated Circuit Breaker
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformer
SF6 Insulation Current Transformer or Voltage
Transformer
SF6 Insulated Bus System
15
30°
60°
64±0.5
O
41.5±1
93±2
24
M x1.5
Degree of protection
Ambient conditions
Contact type
Leakage rate
Impact rating
Contact electrical parameters
Watch glass
Weight
Process connection
Installation method
Electrical connection
Insulation property(contact part)
IP65
-40℃ ~ +70℃ , relative humidity:≤ 95%RH
Magnetic holding electronic relay
≤ 1 × 10-9 Pa·m3
/s (Helium leakage inspection)
30 g
Maximum switching voltage:380VAC/240VDC
Maximum switching current:5A
Laminated safety glass
0.3kg
M20×1.5 (customizable)
Radial or Axial
Preset cable
Insulation resistance: >100MΩ (DC500V)
Power frequency withstand voltage: 2kV, 50/60Hz, 1min
Technical parameters
Scale range
Accuracy of transmitter
-0.1 ~ 0.9MPa
Pressure:±0.5%FS
Temperature:±1℃
Pressure at 20℃:±1.0%FS
Dimensions
16 DT26 Density Monitor
DT26
Density Transmitter
Features
Application Options
Description
DT26 Density Transmitters are used to monitor SF6 gas
density in sealed tanks. It can provide multiple solutions
to support new substations and the renovation and upgrading of existing substations.
SF6 Gas Insulated Switchgear (GIS)
SF6 Insulated Circuit Breakers
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformer
SF6 Insulated Current Transformer or Voltage
Transformer
SF6 Gas Insulated Busbar Systems
SF6 Insulated Inflatable Cabinet
SF6 Insulated RMU
SF6 gas remote density transmitter suitable for medium and high pressure system monitoring.
All welded sensor structure, long - term stable sealing performance.
RS485 bus communication(MODBUS RTU).
The EMC characteristics of the transmitter meet
the requirements of IEC 61000-4-2 to IEC 61000-4-6
standards.
Compact design.
Pressure connection: M20 × 1.5(customizable)
Measuring Medium:SF6, Air, N2, SF6 + N2 and other
gases
17
34
130
Ø27
53
M20X1.5
20
Density (P20) measurement accuracy ±1.0%FS
Degree of protection
Ambient conditions
Leakage rate
Electrical connection
Weight
IP65
-40° C to 70° C, relative humidity ≤ 95%RH
≤ 1 × 10-9 Pa·m3
/s (Helium leakage inspection)
Hirschmann Connector
0.2kg
Technical Parameters
Measuring range 0 to 1.0MPa abs.or 0 to 0.2MPa abs.(customized)
Temperature measurement range
Pressure measurement accuracy
Temperature measurement accuracy
-40℃~ +80℃
±0.5% FS
±1℃
Technical Parameters for Remote Module
Power supply
EMC tests
24V DC
IEC61000-4-2:level 4
IEC61000-4-3:level 3
IEC61000-4-4:level 4
IEC61000-4-5:level 4
IEC61000-4-6:level 3
Power consumption < 0.5W
Communication mode RS485
Protocol
Baud rate
ModBus RTU
9600bps
Dimensions
18 DT10 Density Transmitter
DT10
Density Transmitter
Features
Application Options
Description
DT10 Density Transmitters are used to monitor SF6 gas
density in sealed tanks. It can provide multiple solutions
to support new substations and the renovation and upgrading of existing substations.
SF6 Gas Insulated Swithchgear (GIS)
SF6 Insulated Circuit Breaker
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformer
SF6 Insulation Current Transformer or Voltage
Transformer
SF6 Insulated Bus System
Suitable for medium or high volatage systems.
All welded sensor structure, long-term stable sealing performance .
RS485 bus interface (Modbus RTU).
Strong EMC capability.
Measuring Medium: SF6, Air, N2, SF6 + N2 and other
gases
19
Degree of protection
Ambient Condition
Leakage rate
Process connection
Electrical connection
Weight
IP65
-40℃ ~ +70℃ , Relative humidity ≤ 95%RH
≤ 1 × 10-9 Pa·m3
/s (Helium leakage inspection)
M20 x 1.5 (customizable)
M12 x 1 Circular connector
0.1kg
Technical parameters
Measuring range 0 ~ 1.0MPa
Accuracy of transmitter
Temperature:±1℃
Pressure:±0.5%FS
Pressure at 20℃:±1.0%FS
Technical Parameters for Remote Module
Operating voltage
EMC tests
10~30VDC IEC61000-4-2: level 4(15kV)
IEC61000-4-3: Level 3 (10V/m)
IEC61000-4-4: Level 4 (4kV)
IEC61000-4-5: level 3 (1kV /2kV)
IEC61000-4-8: level 5 (100A/m)
IEC61000-4-9: level 5 (1000A/m)
IEC61000-4-10: level 4 Class (30A/m)
Power consumption <0.5W
Communication mode RS485
Communication protocol
Baud rate
Modbus RTU
9600bps
Dimensions
20 RD40 Density Transmitter
RD40
Density Transmitter
Features
Description
The RD40 density transmitter is used to monitor the
temperature, pressure and density of the gas in sealed
tanks, and the functional parameters meet the requirements of the National Grid.
\"QGDW123554-2023 Smart substation technical specification Part 4: Digital remote transmission meter\"
standard. It can be used in the new substation and the
renovation and upgrading of existing substation.
All welded sensor structure, long-term stable sealing performance.
RS485 bus interface, easy to do the system expansion.
Meet the requirements of \"QGDW123554-2023
Smart substation technical specification Part 4: Digital remote transmission meter\".
Compact and beautiful design.
Application Options
SF6 Gas Insulated Swithchgear (GIS)
SF6 Insulated Circuit Breaker
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformer
SF6 Insulation Current Transformer or Voltage
Transformer
SF6 Insulated Bus System
Measuring Medium: SF6, Air, N2, SF6 + N2 and other
gases
21
Degree of protection
Ambient condition
Leakage rate
Process connection
Electrical connection
Impact Rating
Weight
IP65
-40℃ ~ +70℃ , relative humidity: ≤ 95%RH
≤ 1 × 10-9 Pa·m3
/s (Helium leakage inspection)
M20 x 1.5 (customizable)
Hersman connector
50 g
0.4kg
Technical Parameters
Measuring range -0.1 ~ 0.9MPa
Accuracy of transmitter
Pressure:±0.5%FS
Temperature:±1℃
Pressure at 20℃:±1.0%FS
Technical Parameters for Remote Module
Operating voltage
EMC tests
10~30VDC IEC61000-4-2: Level 4
IEC61000-4-3: Level 3
IEC61000-4-4: Level 4
IEC61000-4-5: Level 4
IEC61000-4-6: Level 3
IEC61000-4-8: Level 5
IEC61000-4-9: Level 5
IEC61000-4-10: Level 5
Power consumption <0.5W
Communication mode RS485
Communication protocol
Baud Rate
Modbus RTU
9600bps
Dimensions
22 RDH40
SF6 Gas density and dew transmitter
RDH40
SF6 Gas Density and Dew Transmitter
Features
Description
RDH40 Gas Density and Dewpoint Transmitter is mainly
used to monitor the temperature, pressure, density and
moisture content of SF6 gas in closed containers, with
real-time remote monitoring function. The intelligent
compensation technology is used inside the product,
which can track the nonlinear change of SF6 gas pressure
and the change of micro-water content in real time, and
the measurement is accurate and widely used. Suitable
for monitoring of medium and high voltage systems. It
can be used in the new substation building and the renovation and smart upgrading of existing substation.
Suitable for medium or high volatage systems.
Multi-parameter instrument for simultaneous monitoring of gas dew point, density, pressure and temperature with excellent accuracy.
RS485 bus interface (Modbus RTU).
Small size, beautiful structure.
Remote part of the main electrical performance indicators and specifications
Operating voltage
EMC Class
10~30VDC IEC61000-4-2: Level 4
IEC61000-4-3: Level 3
IEC61000-4-4: Level 4
IEC61000-4-5: Level 4
IEC61000-4-6: Level 3
IEC61000-4-8: Level 5
IEC61000-4-9: Level 5
IEC61000-4-10: Level 5
Power consumption <0.5W
Communication mode RS485
Communication protocol
Baud rate
Modbus RTU
9600bps
Optional features
Measuring Medium:SF6, Air, N2, SF6+N2 and other
gases
Application Range
SF6 Gas Insulated Swithchgear (GIS)
SF6 Insulated Circuit Breaker
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformer
SF6 Insulation Current Transformer or Voltage
Transformer
SF6 Insulated Bus System
23
RDH40 is matched to a 3-way valve
The RDH40 is matched to a medium pressure gauge
64
O
222
105
139
186
130
60
Accuracy of transmitter
Degree of protection
Ambient condition
Electrical connection
Weight
Leakage rate
Process connection
Temperature:±1℃ Pressure:±0.5%FS
Pressure at 20℃:±1.0%FS Dew:±3℃
IP65
-40℃ ~ +80℃ , Relative humidity ≤ 95%RH
M12 x 1 Circular connector
0.4kg
≤ 1 x 10-9Pa · m3
/s (Helium leakage inspection)
G1 (customizable)
Technical parameters
Pressure measuring range
Dew measuring range
0 ~ 1.4MPa(customizable)
-50℃ ~ +20℃
Dimensions
24 MDK40 Density Switch
MDK40
Density Switch
Description
MDK40 Density Switches are used to monitor the density of SF6 gas in sealed tanks, and can be widely used in
medium voltage switchgear and RMU. They’re suitable
for outdoor harsh environments.
They can provide multiple solutions to support new
substations and the renovation and smart upgrading of
existing substations.
Features
Temperature compensation ensures higher set point
accuracy.
Can provide up to three sets of microswitch contacts
allowing instant and accurate switching.
High shock resistance.
Normally closed contacts will not set a false alarm
due to vibration.
Application Options
SF6 Gas Insulated RMU
SF6 Gas Insulated Switchgear
Different measuring ranges
Wide temperature range
Measuring medium:SF6、Air、N2、SF6+N2 and other
gases
25
40
93.58.8
24
123 45 6
Degree of protection
Electrical connection
Ambient conditions
Insulation properties
Installation method
Contact electrical parameters
Leakage rate
Contact type
Weight
Process connection
Impact rating
Pressure element
IP42
Plug-in connection cable size: 0.2mm2
to 2.5mm2
-25° C ~ +60° C, relative humidity ≤ 95%RH
Insulation resistance: >100 MΩ (DC 500V)
Withstand voltage: 2kV, 50/60 Hz,1min
Axial
30W/50VA, 1A (upper limit)
220VDC/380V 50/60Hz (upper limit)
≤ 1 x 10-9Pa · m3
/s(helium leakage inspection)
Mirco switch
0.3kg
G1/4 (customizable)
30g
Bellow
Technical Parameters
Measuring range
Accuracy of set point
0 ~ 3 bar abs. (customizable)
±2.0% @–30 ° C ~ +50 ° C
Dimensions
26 CV Self-closed Valve
CV
Self-Sealing Valve
Description
The CV Self-Sealing Valve is a device connecting SF6 gas
density meter or density monitor and SF6 gas chamber;
after the completion of the assembly, SF6 gas chamber
can be effectively sealed. It can be applied to high and
medium voltage equipment.
Features
Self-sealing: when this valve is disconnected from either side,it can seal and stop the flow of gas.
Can withstand repeated usage.
Can be used on outdoor switchgear.
Can connect SF6 gas filling and vacuum pumping devices.
Can connect SF6 gas recovery truck.
Application
SF6 Gas Insulated Switchgear (GIS)
SF6 Insulated Circuit Breakers
SF6 Insulated Pole-mounted Switch
SF6 Insulated Transformer
SF6 Insulated Current Transformer or Voltage
Transformer
SF6 Gas Insulated Busbar Systems
SF6 Insulated Inflatable Cabinet
SF6 Insulated RMU
Options
Pressure connections: customizable
Nominal diameter: customizable
Nominal bore
Surface finish
Ambient conditions
Leakage rate
DN6、DN8、DN12、DN20 etc
Aluminum: Oxidation treatment
Stainless steel, copper alloys: Not processed
-40° C to 60° C
≤ 1×10-9Pa·m3
/s
Technical Parameters
Valve material stainless steel, aluminum or a copper alloy
27
DN6
M24X1.5
15 14
M20X1.5
45 SW32
DN8
DN12
DN20
Dimensions
28 FMZ Connection Valves
Description
The FMZ Connection Valves is a connecting device of SF6 density monitor to SF6 switch gear. The maintenance personnel can
inspect SF6 density monitor or replace jt without disassembling the device from installed switchgear. It provides a solution to gas density monitor inspection, replacement and gas
filling, without damage to the sealing surface and seal rings of
the switch caused by disassembling of valves in the process of
regular checks. Therefore, it can reduce the leakage rate, improve the work efficiency, and ensure the safe operation of SF6
electrical switch.
Features
The SF6 density meters can be inspected/replaced without
disassembling the SF6 meter/monitor.
Operation can be done by one person alone without removing screws, convenient, labor – saving and time-saving.
Easy for personnel on site to make micro-water detection
and gas filling.
Avoid the damage to sealing surface and seal rings due to
disassembling .
High-quality stainless steel with good looking appearance,
never get rusted.
With stainless steel rain cover, it can resist rain and sun,
greatly improving the reliability and service life of the density
relay.
Nominal bore
Surface Finish
Leakage rate
Ambient conditions
Operating pressure range
Maximum withstand pressure
DN6、DN8、DN12、DN20 etc
Aluminium – anodized Copper alloy – natural
AISI304 stainless steel-natural
-40° C to +70° C
0~1.6MPa
6.4MPa
Needle valve: ≤ 1×10-8Pa·m3
/s
Ball valve:≤ 1×10-9Pa·m3
/s
Technical Parameters
Valve Material Aluminium /Copper alloy/ Stainless steel
Application
SF6 Gas Insulated Switchgear (GIS)
SF6 Insulated Circuit Breaker
SF6 Insulated Pole-Mounted Switch
SF6 Insulated Transformer
SF6 Insulated Current Transformers or Voltage
Transformers
SF6 Insulated Bus System
Options
Pressure connections: customizable
Nominal diameter: customizable
Valve type: needle valve or ball valve
FMZ
Connection Valves
29
Schematic diagram (high-voltage version)
Schematic diagram (medium voltage model)
174
149 37
Dimensions
Check the make-up port
Valve switching Ontology
Meter port
30 VDA-03
Gas Density Monitor Calibrator
VDA-03
Gas Density Monitor Calibrator
Features
Description
The VDA-03 Gas Density Monitor Calibrator is an intelligent, fully automatic calibration instrument that uses
advanced embedded microprocessors to test the performance of Gas Density Monitors for SF6, SF6/N2 hybrid
and SF6/CF4 hybrid gases. The device has two working
modes: zero-pressure mode and working pressure
modes. Working pressure calibration mode tests the
accuracy of GDM from the rated filling pressure to zero,
while zero pressure mode starts from zero and rises to
the rated pressure. This portable calibration instrument
provides great convenience for the operation, testing,
calibration and maintenance of electrical products.
The instrument adopts a dual gas path design, supporting two
types of gas supply methods: external gas cylinder and internal
gas pump.
The instrument is equipped with a high-performance proportional valve, and the calibration rate can be adjusted
automatically according to the parameters of the calibrated
instrument.
It supports the calibration of various gas types of instruments,
including pure SF6, SF6/N2 mixed gas, and SF6/CF4 mixed gas.
The output voltage supports 24VDC and 110VDC voltage out,
and has the function of measuring contact resistance.
It supports zero pressure and working pressure calibration
methods.
The product is equipped with a 7-inch color touch screen for
easy observation and operation.
It is equipped with a complete set of transition adapters, so that
most models of switches' density monitors can be field-on-site
calibrated without disassembly.
The engineering plastic case is beautiful and durable, with a
high protection level.
It is equipped with a large capacity memory, and the calibration
data can be stored for a long time.
It is equipped with a high-speed micro thermal printer, which
can print the calibration results after the calibration is completed.
It has a USB interface for easy export of historical data and system upgrades.
31
Accuracy
Full calibration time ≤ 5min
Resolution
Density monitor contact calibration
0.1 grade
Pressure display resolution 0.0001Mpa; Temperature
display resolution 0.1℃
Single signal (single alarm, single lockout), single alarm
and single lockout, single alarm and double lockout
Technical parameters
Power supply Internal rechargeable lithium battery or external 220VAC
Measuring range Pressure calibration range 0~1Mpa;
Temperature measurement range -40℃ ~+100℃
Configuration
Calibrator: 1 Unit
Essential accessories: 1 self-sealing connection tube; 1 calibration point sampling line; 1 temperature sensor; 1
external gas cylinder & connecting tubes; 1 power cord; 1 production inspection record & 1 user manual.
Optional accessories: 1 toolbox (including a complete set of adaptors)
32 JXQ Series RS485 Hub
JXQ Series
RS485 Hub
Description
JXQ series RS485 hub is a RS-485 bus splitter designed
to address the requirements of large RS-485 systems
in complex electromagnetic environments. The product supports transmission rates up to 115.2Kbps. To
ensure safe and reliable data communication, the
RS-485 interface uses optical isolation technology
to prevent lightning surges from introducing into the
converter and equipment. The built-in optical isolator
and 1500W surge protection circuit provide 2500V isolation voltage and effectively prevent lightning, ESD,
and grounding interference. The power supply uses an
external switching power supply for reliable operation.
In the RS-485 mode of operation, the discrimination
circuit automatically senses the direction of data flow
and switches the enable control circuit automatically, solving the delay problem of RS-485 transceiver
conversion easily. It is widely used in power collection
systems and is a high-performance and cost-effective
data interface conversion product.
JXQ series RS-485 HUB provides star-type RS-485 bus
connection. Each port has short circuit and open circuit protection. Optical isolation of 2500V allows users
to easily improve the RS-485 bus structure, divide
network segments, and improve communication reliability. When lightning or equipment failure occurs, the
problematic network segment will be isolated to ensure the normal operation of other network segments.
This performance greatly improves the reliability of
the existing RS-485 network and effectively reduces
maintenance time of the network.
Application Features
The interface adopts optical isolation technology to
prevent lightning surges from introducing into the
converter and equipment.
It automatically detects and controls the RS485 data
stream, and can automatically generate the RS485
transceiver switching enable signal based on the
transmitted data.
Each port has short circuit and open circuit protection, and any interface failure will not affect the normal operation of other interfaces.
The number of RS485 interfaces is optional for 4 or 8
ports.
RS485 Bus Connections
33
12~48VDC
12~48VDC
JXQ-RS-08
JXQ-RS-04
145
90
135
70
40
10
Operating voltage
Transmission medium
Operating mode
Interface protection
Transmission rate
Size
Operating environment
Installation method
Eight RS485 ports Rail installation
Four RS485 ports Rail installation
DC 12-48V with a current of 350mA
twisted pair or shielded wire
asynchronous half-duplex
Using optical isolation
300bps-115.2kbps
145mmx90mmx40mm
Temperature: -40℃ ~+85℃ , relative humidity: 5%~95%
Rail installation
Technical parameter
Model Instruction Installation Operate power
Interface characteristics
Signal display
The interface is compatible with EIA/TIA's RS-232C
and RS-485 standards
Eleven signal indicators including power (PWR), transmit
(TX), receive (RX), and fault (E1-E8) indicators
Options
Dimensions
34 DA Series
Digital meter monitoring terminal
Description
DA-type digital meter monitoring terminal is a communication
management machine product based on embedded hardware.
The system adopts Linux operating system and is stable, reliable, and easy to use. It adopts a highly integrated new generation of 32-bit computer internally, and can be integrated with
our company's dedicated communication management software. It can be used to collect information from the entire field
of power distribution automation system and send it to the
local background or remote dispatching master station, and
at the same time, it will pass the command of the background
or master station to each measurement and control device to
achieve local or remote control.
DA-type digital meter monitoring terminals can directly collect
data from all devices in the automation system, supporting
over 100 protocols, such as Modbus, IEC101, IEC103, IEC104,
IEC61850, CSC2000, DL645, etc., and send them to the monitoring background through the user-specified communication
protocol (101, 104, Modbus, CDT, etc.) and communication medium (ethernet, fiber optics, etc.), completing the background
monitoring of the entire site.
Features
Support Modbus, IEC101, IEC103, IEC104, CSC2000, DL645
and other up to 100 protocol conversion, fully support
IEC61850 standard.
Support the State Grid \"Smart Substation Technical specification Part 4: Digital remote meter\" meter access.
Support multi-channel adaptive industrial 10/100M Ethernet, 2/4 optional; Multiple RS485 ports, 4/8/16 optional.
Support one single mode and one multi-mode fiber output.
Support a variety of voltage access, a variety of installation
methods.
Support data storage, block logic programming.
The RS485 port uses optoelectronic isolator.
Application
Online Monitoring of Digital Meters
Power consumption <15W
Technical parameters
Ambient condition -40℃ ~ +85℃
Operating voltage 220VAC/220VDC (some series use DC24V power supply)
DA Series
Digital Meter Monitoring Terminal
35
IED-8240
IED-8600
118 106
34 4-O 4
142
36
480
230
438
44
9~24VDC
12~24VDC
85~230VDC/VAC
85~230VDC/VAC
85~230VDC/VAC
DA8240
DA8600-8-D
DA8600-8
DA8600-16
DA8600-8-F
Two 10M/100M Ethernet ports and four RS485 ports Flat mounting
Four 10M/100M Ethernet ports and eight RS485 ports
Four 10M/100M Ethernet ports and eight RS485 ports
Four 10M/100M Ethernet ports and sixteen RS485 ports
Two 10M/100M Ethernet ports, eight RS485 ports,
One single-mode Fibre Channel port and one multi-mode
Fibre Channel port
Flat mounting
1U rack mounting
1U rack mounting
1U rack mounting
Model Instruction Installation Operate power
Dimensions
36 GLM type
SF6 gas chamber leak monitoring system
Description
The SF6 gas leakage quantitative alarm system is based
on the current situation in which the power system emphasizes safe production, and is an intelligent online
detection system designed and developed to provide
personal health and safety protection for the personnel
in the power distribution device room where SF6 equipment is installed.
The system mainly detects the SF6 gas content and oxygen content in the ambient air. When the SF6 gas content in the environment exceeds the standard or lacks
oxygen, it can alarm in real time. At the same time, the
ventilation system is automatically turned on, with temperature and humidity detection, working status voice
prompts, remote alarm, Historical data query and many
other rich features.
Features
The use of high-sensitivity imported sensors, long
life, with false alarm filtering software, to avoid false
alarms.
The micro-monitoring technology can send out
early on-site warnings and indicate the locations of
gas leaks, promptly notify personnel in hazardous
locations to evacuate, find and eliminate sources of
leakage, and protect operating equipment.
A cable connects the SF6/O2 transmitter, infrared,
main unit, and fan controller, and can be discretely
combined to achieve high field adaptability.
Multi-point monitoring at the same time meets the
needs of the site environment and improves monitoring reliability.
The data can be transmitted far to the telecontrol
control center via the RS485 or RS232 bus. The control center can also directly inquire and control the
monitoring system.
The well-designed high-frequency, low-current,
high-voltage switching power supply is applied to
the SF6 sensor monitoring head, which is characterized by safety, reliability, and high efficiency. Take
full advantage of the flexibility of the microcontroller.
85V ~ 265V AC, to meet the different field environment needs
Large-screen LCD color display, beautiful and generous, running status at a glance. Simple operation
interface, simple operation.
The large-capacity memory supported by the system host can store historical data for more than one
year. The excellent performance of the query system
software ensures that the system can quickly query
historical data in seconds.
GLM Type
SF6 Gas Leakage Quantitative Alarm System
37
SF6 quantitative leak monitoring alarm system host.
Accessories: SF6/O2 double gas transmitter (on-demand), 1 fan controller, 1 warning light, and cable (several).
Configuration
SF6 gas detection sensitivity
Oxygen concentration alarm point
Oxygen measurement accuracy
Temperature display range
Humidity display range
Input power
Fan ventilation time setting
Alarm output point power supply
Data recording capacity
Fan output contact power supply
Communication
±5% setting
18%
<0.4%
-50 ~ 99° C
0 to 99% RH
85 ~ 265V AC
15MIN/time or user set arbitrarily
2A
10000 entries
16A
RS-485 standard protocol
Technical indicators
SF6 gas concentration alarm range 50 ~ 2000PPM
(alarm point can be set up, the state regulations 1000PPM)
38 SF6 Gas Monitor and Receiver Based on LoRa Wireless
Transmission Technology (LS-WC and LS-WT Series)
Features
Product Overview
SF6 (Sulfur Hexafluoride) gas is widely used as an excellent insulating and arc-suppressing medium in medium and high voltage, as well as in high voltage switchgear and GIS. The density
index of SF6 gas is crucial to its insulation and arc-suppressing
performance.
SF6 Gas State Monitor and Receiver (LS-WC and LS-WT series)
are self-developed monitoring products by our company. The
monitor can adapt to our full range of transmitters and remote
density relays, monitoring SF6 gas pressure, temperature, density, and moisture content in real time. The data is transmitted
back to the background system in real time through wireless
LoRa data transmission. The background system can perform
online monitoring and analysis, and achieve functions such as
real-time data query, historical data statistics, pre-set alarm
reminders, and data curve query for all data. This system is
mainly designed for real-time monitoring of critical equipment
such as SF6 gas insulated switchgear, GIS, transformers, and
mutual inductors in various high-voltage electrical devices.
The monitor is powered by a battery and transmits data wirelessly, without the need for cables on site. The transmitters
and remote density relays can be powered by the monitor,
without the need for separate power supply on site.
The monitor is powered by a battery, without the need for
cables on site, enabling non-stop upgrade and transformation of online monitoring systems.
The monitor and receiver have user-friendly human-machine interfaces, facilitating field debugging and testing.
The monitor can adapt to our full range of transmitters
and remote density relays (with a accuracy of full scale
1.0), which can be configured according to customer
needs with different functions, ranges, and interface sizes.
It is suitable for both indoor and outdoor installations.
The battery uses a large capacity lithium battery, with a
service life of over 10 years (related to the data collection
period).
The receiver has data storage function; it can store data
for over 10 years.
The background software has data storage, query, and
statistical analysis functions.
It has a RS485 bus interface that can upload pressure,
temperature, and density data in real time.
It has 470MHz and 2.4GHz optional frequencies for wireless transmission.
Options
The receiver has an RS485 MODBUS RTU output
or a network port TCP/IP output.
It comes with a background software package.
The receiver can be equipped with an instrument
cabinet.
Applications
SF6 Insulated Combination Apparatus (GIS)
SF6 Insulated Circuit Breaker
SF6 Insulated On-site Switch
SF6 Insulated Transformer
SF6 Insulated Mutual Inductor
SF6 Insulated Busbar System
SF6 Gas Monitor and Receiver Based on
LoRa Wireless Transmission Technology
39
Monitor: 144 × 88.5 × 66.5mm
Receiver: 226 × 162 × 40mm
Instrument box: 330 × 235 × 68mm
Button
Monitor
Receiver
Membrane keypad, with a life of 2 million presses at a force
of 300gf Keypad
Screen
Screen
Resolution: 128x64 Dot ; Viewing size: 54.2x32.5mm;
Supply voltage: 3.3V; Supply current: 45mA
Resistive touch 7-inch LCD screen;
Resolution: 1024*600
Battery
Power supply
Type: Lithium thionyl chloride battery;
Nominal capacity: 19AH; Voltage: 3.6V
12V DC @1A (manufacturer can provide 220Vac adapter)
Installation method Metal zip tie installation
Protection grade
Antenna
Operating temperature
Installation method
IP65
Suction cup antenna; Feeder line: 2m (2m~20m)
-40° C ~ +70° C
Wall mounted installation
Standby current
Other hardware
<10uA
16G SD card
Transmitter interface
Signal interface
Power supply: 12V@20mA; Communication: RS485 rotocol;
Private protocol can be customized
Double RS485 interface, two interfaces can use different
communication protocols; RJ45 interface: 10M/100M;
USB interface: 2.0
O 62
205.4
226
162
40
144
88.5
66.5
163.5
43
Technical Parameters
Dimensions
TRUSTED
PARTNERS
UNIFYING THE POWER OF DIGITAL INTELLIGENCE,
CONTRIBUTING TO THE ESTABLISHMENT
OF INNOVATIVE POWER SYSTEM
TO BE A GLOBAL LEADER IN DIGITAL
AND INTELLIGENT ELECTRICAL INSTRUMENTS
INTEGRITY & PRAGMATISM,INNOVATION &
COOPERATION, STRIVING FOR EXCELLENCE,
SERVING CUSTOMERS
MISSION
VISION
VALUES
TEL: +86 - 21 - 5442 0482 FAX: +86 - 21 - 5442 1043
ADD: NO.50,LANE 3679,JINDU ROAD,
XINZHUANG INDUSTRIALZONE,SHANGHAI,P.R.CHINA
INSULATED GAS
MONITORING SERIES
MEDIUM VOLTAGE
LANSO KONLY (SHANGHAI)INSTRUMENTS CO.,LTD.
WWW.LANSOINSTRUMENTS.COM