KAYTUSTM Storage Brochure
World-leading IT Infrastructure Provider
Compute Power Defines Productivity
Intelligent Centralized Storage Platform
KAYTUS,astheforefrontofIinfrastructureinnovationproudlypresentsasuiteofgroundbreakingpenandcfridly infrastructure solutions tailored for cloud,Al,and enterprise applications.With anagile'platform ^ + modularization' development approach,weareadeptatswiftlyaligningwiththeevolvingdemandsofourusers.Asastorageleader,KaytusIntelligent Storage Platformfocusesonthetwocorevaluesof "stableandreliable"and"intellgentandeficient"andiscommittedto helping users store,use and manage data assets well,soas to maximize the value of customers'data.
Product Highlights and Customer Values
>Leading architecture and high availability
Enterprisestoragesystemssupportthe mostcriticalbusinessdata (suchasdatabases,ERP,etc.)andanyunplanned downtimeordataunavailabiltycanleadtosignificanteconomic losses.OurstoragesystemsadoptA-Aarchitecturesupporting seamlessonlineswitchingoffaultcontrolerandcorecomponentsarefullyredundanttoeliminatesinglepointoffailureand achieve high availability of storage system,ensuring high continuity accessto upper business systems.
Ultimate performance and improve efficiency
Financialtransactionsseizeadvantageofmicrosecond,andthepeaktransactionvolumeofre-commerceis hundredsof thousands tomillonspersecond.ERPorder processing speedaffects theeficiencyofsupplychain.Ourstorage systems adoptsal-flashrchitecture,withinteligentalgorithmsoptimizingdatareadandwriteprocessesend-to-end,esultingin performanceuptomilionspersecondwithmicrosecond latencyimproving theeficiencyofbusinesssystemobviously.
>High reliable and always online
Data centers mayencounternaturaldisasters,suchasearthquakes,floods,fires,etc.resultinginsuddensutdowofthe computerroom,whichwillaecttheupperbusinesssystemandevencausedataloss,andthelosscausedtocustomersis dificultoestimate.Ourstoragesystems supportmultipledataredundancy modes,localsupportforwrite-timereplication snapshot,cloneandremotesupportfor intellgentmetro,remotecopy,realizingremotedisasterrecoverytoensureDC operating business system high continuity and availability.
KAYTUS Centralized Storage
High-end Flash Storage
04 KS18000G7-F
LeadingArchitecture&ExcellentPerformance Centralized High-end All-flash Storage
06 KS18000G7
Leading Architecture& High Quality Centralized High-end Hybrid Flash Storage
Mid-range Flash Storage
08 KS5000G5-F
Ultimate Performance& Stability Centralized Mid-range All-flash Storage
10 KS5000G5
Ultimate Performance&Stability Centralized Mid-range Hybrid Flash Storage
KAYTUS Centralized Storage Brochure
Entry-level Flash Storage
12 KS3000G7-F
Entry-level High-performance Centralized All-flash Storage
16 KS2000G7
Entry-level Cost-effective Centralized Hybrid Flash Storage
14 KS3000G7
Entry-level Exceptional Cost Performance Centralized Hybrid Flash Storage
KAYTUS
KS18000G7-F Leading Architecture& Excellent Performance Centralized High-end All-flash Storage
Product Overview
TheKS180oG7-Fhigh-endal-flashstorageisaunifiedstoragesystemdesignedforlarge-sizedenterprisesandprovides bothSANandNASservices.Itadoptsanewalflasharchitecture,with intellgentalgorithmsoptimizingdatareadandwrite processes end-to-end,resutinginhighersystemperformanceandlowerlatency.Withthestorageoperatingsystem,rich softwarefunctions,andindustry-leadingcontrolersfull-mesharchitectureandhardwareplatformsspeciallydesignedfor cloudcomputinganddatabaseenvironments,itisperfectlysuitedforapplicationscenariosincluding large-sizedcloud, virtualizationatabasesVandflesringacrosriossctorssuchaianceandmafacturingeF standsoutintheindustrywithleadingarchitectureandextremelyhighperformance,oferingawiderangeofeficient,flexible andcomprehensivebackupanddisasterrecoverysolutions toeffectivelyensure businesscontinuityanddatasecurityand providebetterdataservice experience forusers.Itis widelydeployedacross varioussectors,including finance, telecommunications,energy, healthcare,education,and manufacture etc.
Product Features
■ Leading Architecture
> The industry-leading four controllers in one enclosure tightly coupled architecture,controllers full-mesh fully interconnected architecture with controllers cyclic mirroring maximum tolerance for three controllers failures,and front-end business zero uninterrupted.
> Supports full sharing of four controllers in the backend,with shared visibility and processing of disks,disk enclosure,RAID groups,storage pools,etc.,achieving efficient and balanced IO distribution and processing.
> Supports four controller load balancing,self-developed multi-path toachieveseamless integration between hostand storage,utilizing intelligentshardingalgorithmstoachieve two-level load balancingwithin the IO stack,resulting in better IO processing efficiency. >Supports disk enclosures level redundancy,achieving balanced distributionofdataandchecksumblocksacross different disk enclosures,ensuing data read&writeaccess normally even single disk enclosure failing.
■ Ultimate Performance
> AdoptsiTurbo intelligentaccelerationengine. Intelligent CPU partition technology to achieve dedicated cores to ensure IO read& write efficiency,significantly improving CPU utilization. Intelligent IO sensing technology realizes cold and hot data splitting to improve data processing effciency. Intelligent cache pre-reading actively predicts user's future data needs and reads them to the high-speed layer in advance,reducing latency by 5 5 % and improving 8K IO performance up to 2 millions with us latency.
> Supports the latest generation PCle 5.0 Intel CPU platform, controllers are interconnected at high speed through RoCE protocol network.With the newall-flash architecture, intelligent algorithms are used to optimize data read and write end-to-end,and operations such as data compression, stripaggregation,and overall writingare implemented to effectively reduce SSD writeamplificationand the performance of storage system is improved significantly.
■Stable&Reliable
> The storage system adopts controllers fully interconnected and disk enclosure redundant design enabling seamless switching of controllerand disk enclosure faults.All core componentsare fully redundant to eliminate single point of failureand achieve high availability of the storage system.
> There are multiple data redundancy protection modes,local support forwrite-time replication,snapshot,clone and incremental backup.Supports for intelligentmetro,remote copy,3DC and other disaster recovery solutions to ensure business continuity and apply high availability.
> Intelligent RAlD technology,redundant data blocks can be quicklyrestored,datablocksand hotbackup blocksare distributed onall disks.Aftera bad disk appears,allhard disks participate in reconstruction,and the data reconstruction time isshortened tominute levelwith reducing the risk of RAID failure and enhancing system reliability.
> Supports online hardware expansion,online firmware upgrade,and online system maintenance to ensure the continuity of the service system.
■Easier Management
> Graphical interface design:Provides online monitoring of storage performance,capacity,and systemstatus,aswell as DMP maintenance wizard for fault events.
> Efficient configuration management: Supports GUl and CLl management operations,supports configuration of multiple role permission control,and realizes efficient management of storagedataaccesspermissions.
> IntelligentHeterogeneousVirtualization,heterogeneous storagedevices of mainstreamstoragevendors eliminate platform differencesand realize efficient reuse of storage devices,at thesame time,enhance data mobilityand eliminate data islands,and the unified management of resources is simple and efficient.
>The Intelligent Management platform can effectively solve IT system operationand maintenance problems,improve operationandmaintenanceefficiency,reduce operationand maintenance costs,ensure data reliabilityand availability, and ensure business continuity.
Technical Specifications
| Product Model | KS18000G7-F |
| Control Enclosure | KS18000G7-F-M2D(4U2C) |
| Disk Enclosure | JBOD:2U25/3U48,SAS protocol Shared JBOD:2U25,SAS protocol EBOF:2U25,NVMe protocol |
| RAID Level | InRAID 5/6, InRaid 3C |
| CPU | Multiple multi-core PCIE5.0 CPUs |
| System Cache (single-controller) | 256GB-2TB |
| Front Interface Cards (Max.) | 28pcs |
| Front I/O Card Specifications | 16/32/64 Gb FC card,10/25/100 Gb Ethernet NIC,and 25/100 Gb RoCE NIC |
| DRAM Cache Protection | Continuousprotectionagainst twoconsecutiveBBUpowerfailures,ensuring thatbusinessoperations remainuninterrupted within 2~5 second power interruption |
| Improved Resource Efficiency | Intelligentinn)tell)telliioatio)tellomrso IntelligentVolumeTune(InTune),IntellgentHeterogeneousVirtualization (InVirtualization),IntelligentManagement (InManagement), IntelligentDedupe(InDedupe) |
| Data Protection Software | IntelligentSnapshot (SnapSot),ntellgentClone(nlone)ntelligentBackup(nBackup),IntelligentRemoteCopy (InRemoteCopy),IntelligentMetro (InMetro),IntellgentErase (InErase),IntelligentEncryption(InEncryption) |
| Key Service Assurance Dimensions (W*D*H mm, | Intelligent Quality of Service (InQoS),and IntelligentAutomaticCachePartition (InAutoPartition) |
| D indicates the depth when installed in the rack) | 4U control enclosure:447.00 x843.20 ×175.00 mm (17.60× 33.20 × 6.89 in.) |
| Weight (without Drive, kg/lbs) | 4U2C control enclosure: 55.0/121.26,4U4C control enclosure: 85.0/187.40 |
| Max Power of the Power Supply | 4U2C control enclosure:20ooW,4U4C control enclosure: 2700W |
| InputoagelUtlorealie56 (180-320 VDC,IEC60320-C14) 4U4C controlenclosure:AC 220Vor AC110Vdualive wire(180-264 VAC,16A,50-60Hz,IEC60320-C20),DC 240V (180-320 VDC,IEC60320-C20) |
KAYTUS
KS18000G7 Leading Architecture& High Quality Centralized High-end Hybrid Flash Storage
Product Overview
TheKS180o0G7high-endhybridflashstorageisaunifiedstoragesystemdesignedforlarge-sizedenterprisesand provides bothSANandNSservices.Withthestorageoperatingsystem,richsoftwarefunctions,andindustry-leadingcontrolers full-mesharchitectureand hardwareplatformsspeciallydesignedforcloudcomputinganddatabaseenvironments,it is perfectlysuitedforpplicationenariosincdinglrge-sdcoud,ituazation,databassVDndfileingos varioussectorssuchas financeand manufacturing.TheKS180oG7standsoutin theindustrywith leading architectureand extremelyhighperformance,oferingawiderangeofeficient,flexible,andcomprehensivebackupanddisasterecovery solutionstoefectivelyensurebusinesscontiuityanddatasecurityndprovidebeterdataserviceexperienceforusers.Itiswidely deployedarosriotorsiuingce,tcommatiosgaltareucationdactt
Product Features
■ Leading Architecture
> The industry-leading four controllers in one enclosure tightly coupled architecture,controllers full-mesh fully interconnected architecture with controllers cyclic mirroring, maximum tolerance for three controllers failures,and front-end business zero uninterrupted.
> Supports full sharing of four controllers in the backend, with shared visibility and processing of disks,disk enclosure, RAID groups,storage pools,etc.,achieving efficient and balanced IO distribution and processing.
> Supports four controller load balancing,self-developed multi-path to achieve seamless integration between host and storage,utilizing intelligent sharding algorithms toachieve two-level load balancing within the IO stack, resulting in better IO processing efficiency. > Supports disk enclosures level redundancy,achieving balanced distribution of data and checksum blocksacross different disk enclosures,ensuing data read&write access normally evensingle disk enclosure failing.
■ Ultimate Performance
> Adopts iTurbo intelligentaccelerationengine.Intelligent CPU partition technology to achieve dedicated cores to ensure IO read& write efficiency,significantly improving CPU utilization. Intelligent IO sensing technology realizes cold and hot data splitting to improve data processing effciency. Intelligent cache pre-reading actively predicts user's future data needs and reads them to the high-speed layer in advance,reducing latency by 50 % and improving IO processing efficiency by 30 %
> Supports the latest generation PCle 5.0 Intel CPU platform, controllers are interconnected at high speed through RoCE protocol network,realizing a 30 % improvement in storage system performance.Supports 2U12,2U25,and 3U48SAS JBOD and 2U25 NVMe EBOF,flexible combination of HDD and SSD,to provide higher performance and larger capacity datastorage experience ondemand.
■Stable&Reliable
> The storage system adopts controllers fully interconnected and disk enclosure redundant design enabling seamless switching of controllerand disk enclosure faults.All core componentsare fully redundant to eliminate single point of failureand achieve high availability of the storage system.
> There are multiple data redundancy protection modes,local support forwrite-time replication,snapshot,clone and incremental backup.Supports for intelligentmetro,remote copy,3DC and other disaster recovery solutions to ensure business continuity and apply high availability.
> Intelligent RAlD technology,redundant data blocks can be quicklyrestored,datablocksand hotbackup blocksare distributed onall disks.Aftera bad disk appears,all hard disks participate in reconstruction,and the data reconstruction time isshortened tominute levelwith reducing the risk of RAID failure and enhancing system reliability.
> Supports online hardware expansion,online firmware upgrade,and online system maintenance to ensure the continuity of the service system.
■Easier Management
> Graphical interface design:Provides online monitoring of storage performance,capacity,and systemstatus,aswell as DMP maintenancewizard for fault events.
> Efficient configuration management: Supports GUl and CLl management operations,supports configuration of multiple role permission control,and realizes efficientmanagement of storage data access permissions.
> IntelligentHeterogeneousVirtualization,heterogeneous storagedevicesofmainstreamstoragevendorseliminate platformdifferencesand realize efficient reuse of storage devices,at the same time,enhance data mobilityand eliminate data islands,and the unified management of resources issimpleand efficient.
> The Intelligent Management platform can effectively solve IT system operationand maintenance problems,improve operation and maintenance efficiency,reduce operationand maintenance costs,ensure data reliabilityand availability, and ensure business continuity.
Technical Specifications
| Product Model | KS18000G7 |
| Control Enclosure | KS18000G7-M2D(4U2C) |
| Disk Enclosure | JBOD:2U12/2U25/3U48, SAS protocol Shared JBOD: 2U25,SAS protocol EBOF:2U25,NVMe protocol |
| RAID Level | InRAID 5/6, InRaid 3C |
| CPU | Multiple multi-core PCIE5.0 CPUs |
| System Cache (single-controller) | 256GB-2TB |
| Front Interface Cards (Max.) | 28pcs |
| Front I/O Card Specifications | 16/32/64 Gb FC card,10/25/100 Gb Ethernet NIC,and 25/100 Gb RoCE NIC |
| DRAM Cache Protection | Continuousprotectionagainst twoconsecutiveBBU powerfailures,ensuring thatbusinessoperations remainuninterrupted within 2~5 second power interruption |
| Improved Resource Efficiency | Intelligentinn)tellnA()telliaio(atio)tellieomresoo IntelligentVolumeTune(InTune),InteligentHeterogeneousVirtualization (InVirtualization),InteligentManagement (InManagement), IntelligentDedupe(InDedupe), IntelligentTier(InTier) |
| Data Protection Software | IntelligentSnapshot (napSot),ntellgntClone(none)ntelligentBackup(nBackup),IntelligentRemoteCopy (InRemoteCopy),IntelligentMetro (InMetro),IntellgentErase (InErase),IntelligentEncryption(InEncryption) |
| Key Service Assurance Dimensions (W*D*H mm, | Intelligent Quality of Service (InQoS),and IntelligentAutomaticCachePartition (InAutoPartition) |
| D indicates the depth when installed in the rack) | 4U control enclosure: 447.00 ×843.20 ×175.00 mm (17.60 × 33.20 × 6.89 in.) |
| Weight (without Drive,kg/lbs) | 4U2C control enclosure: 55.0/121.26,4U4C control enclosure: 85.0/187.40 |
| Max Power of the Power Supply | 4U2C control enclosure:20ooW,4U4C control enclosure: 2700W |
| Input Voltage of the Power Supply | 4U2C controlenclosure:AC 220Vor AC110Vduallive wire(180-264VAC,10A,50-60Hz,IEC60320-C14),DC 240V (180-320 VDC,IEC60320-C14) 4U4C control enclosure:AC220VorAC110Vdualive wire(180-264VAC,16A,50-60 Hz,IEC60320-C20),DC 240V (180-320VDC,IEC60320-C20) |
| Storage Temperature | -40C to 70C(-40Fto158F)(excludingBBUand HDDin the server),0°Cto 70C(32Fto158F)is recommended |
KAYTUS
KS5000G5-F
Ultimate Performance&Stability Centralized Mid-range All-flash Storage
Product Overview
TheKS50G5-Fmid-rangeallfashstorageisaunifiedstoragesystemdesignedformission-cricalappicationsofmedium-and large-sizedenterprisesandprovidesbothSANandNASservices.Itadoptsallflasharchitecturewithinteligentalgorithms optimizingdatareadandwriteprocessesend-toendresultinginghersystemperformanceandlowerlatency.Withthestorage operatingsystem,richsoftwarefunctions,andindustry-leadinghardwareplatformsspecialydesignedforcloudcomputingand databaseenviromentsitdeqatelyetsthdatastoageaddiastercoeryeedsfitalatioiing andotheraplication.Teo5-Ftadsoutinteidustrychevingexeptioalstadardsinformancefutiality reliabilitybilityIdelylootosinctocaiog education,and manufacture etc.
Product Features
■ Ultimate Performance
> The industry-leading Active-Active storage architecture is adopted to achieve load balancing between controllers, eliminate controller performance bottleneck,and improve storage system performance.
> Powered by the Intel multi-core processors and equipped with leading communication link, the storage platform employsa brand-newall-flash optimizationalgorithm,which performs data compression,stripaggregation,and data flushing sequentially during data writing, effectively reducing SSD write amplification.The system supports global garbage collection (GC) technology and TRIM commands,which reduce the movement of invalid data within the drive,prolong the lifespan of SSDs,and consequently improve system performance obviously.
> Intelligent compression&deduplication,the maximum reductionratiocanreach5:1,significantlyimprovethe efficiency of space utilization.Intelligent deduplication, to achieve effcient deletion of duplicate data, higher return on equipment investment.
■Flexible Extension
> Supports 2U25 specification controller enclosures,employed SAS SSD,and NVMe SSD,to provide higher performance and larger data storage capacity.
> Supports 2U25 SAS JBOD and 2U25 NVMe JBOF disk enclosures,which can be cascaded vertically in multiple levelsas required to flexibly expand storage space and reduce investment costs.
> The mid-range active storage system supports online scale-out to multi-controller and TB-level cache,allowing customers to linearly increase the storage capacityand performance to meet the demands of rapidly changing businesses.
> Supports the simultaneous use of IP-SAN,FC-SAN, RoCE, NFS,CIFS,and FTP.A set of storage supports multiple application platforms,and the systemarchitecture is simpler to work and manage.
■Stable&Reliable
> The storage system adopts full redundancy architecture and modular design,with all core components being fully redundant to eliminate single point of failure and achieve high availability of the storage system.
> There are multiple data redundancy protection modes, local support for write-time replication,snapshot,clone and incremental backup.Support for intelligent metro,remote copy,3DC and other disaster recovery solutions to ensure business continuityand apply high availability.
> IntelligentRAlD technology,redundant data blocks can be quickly restored,data blocks and hotbackup blocks are distributed onall disks.Aftera bad disk appears,all hard disks participate in reconstruction,and the data reconstruction time is shortened to minute level with reducing the risk of RAID failure and enhancing system reliability.
> Supports online hardware expansion,online firmware upgrade,and online system maintenance to ensure the continuity of the service system.Supports continuous BBU power failure protection for 2 times,and business is not interrupted within 2S\~5S,easily respond to risks such as power outagesat data centers.
■Easier Management
> Graphical interface design:Provides online monitoring of storage performance,capacity,and system status,as well as DMP maintenance wizard for fault events.
> Efficient configuration management: Supports GUl and CLl management operations,supports configuration of multiple role permission control,and realizes efficient management of storage dataaccess permissions.
> IntelligentHeterogeneousVirtualization, heterogeneous storage devices of mainstreamstorage vendors eliminate platform differences and realize efficient reuse of storage devices;at the same time,enhance data mobility and eliminate data islands,and the unified management of resources is simple and efficient.
> The IntelligentManagement platform can effectively solve IT system operation and maintenance problems,improve operationand maintenance efficiency,reduce operation and maintenance costs,ensure data reliabilityand availability, and ensure business continuity.
Technical Specifications
| Product Model | KS5000G5-F | ||
| Control Enclosure | KS5000G5-F-MS25(2U25) | KS5000G5-F-MS25P(2U25) | KS5000G5-F-MN25(2U25) |
| Disk Enclosure | JBOD:2U25,SAS protocol | JBOD:2U25,SAS protocol JBOF:2U25,NVMeprotocol | |
| Max. Number of Drives (dual-controller) | 1000 | ||
| RAID Level | RAID 0/1/5/6/10,InRAID 5/6 | ||
| CPU | Multiple multi-core CPUs | Multiple multi-core CPUs | Multiple multi-core CPUs |
| System Cache (dual-controller) | 128 GB-256 GB | 256 GB-1TB | 256 GB-1TB |
| Front I/O Card Specifications (dual-controller) | 6pcs | ||
| DRAM Cache Protection | Continuous protectionagainst twoconsecutiveBBUpowerfailures,ensuring thatbusinessoperations remain uninterrupted within 2~5 second power interruption | ||
| Improved Resource Efficiency | Intellgent)el),elo)elo InteligntDedupliation(edupe),tellientVuune(une),nteligntHterogeeousualation(alio and InteligentManagement (InManagement) | ||
| Data Protection Software | Inteligntate)t)li IntelligentMetro (InMetro),IntelligentVdiskMirror (InVdiskMirror),and IntellgentErase (InErase) | ||
| Key Service Assurance | Intelligent Quality of Service (InQoS),and IntelligentAutomaticCachePartition (InAutoPartition) | ||
| Dimensions (W*D*H mm, D indicates the depth when installed in the rack) | 2U25 control enclosure: 446.00× 619× 87.80 mm (17.56 ×24.37× 3.46 in.) | ||
| Weight (without Drive, kg/lbs) | 2U25 control enclosure: 27.8/61.29 | ||
| Max Power of the Power Supply | 2U25 control enclosure: 850W | 2U25 control enclosure: 1200W | |
| Input Voltage of the Power Supply | AC: AC 220 Vor AC 110V duallive wire (180-264 VAC,10 A,50-60 Hz,IEC60320-C14) DC:DC240V(240-340 VDC,IEC60320-C14) | ||
| torageTemnerature | 40°℃ to 70°C(-40°Eto158°E)(excludipgBBU | ||
KAYTUS
KS5000G5 Ultimate Performance&Stability Centralized Mid-range Hybrid Flash Storage
Product Overview
TheKS5000G5mid-rangehybridflashstorageisaunifiedstoragesystemdesignedformedium-and large-sized enterprises andprovidesboth SANandNASservices.Withthestorageoperating system,richsoftwarefunctions,andindustry-leading hardwareplatformsspeciallydesignedforcloudcomputinganddatabaseenvironments,itadequatelymeets thedatastorage anddisasterrecoveryneedsofOLTP/OLAP,virtualization,filesharing,ndotherapplicationsoflargeandmedum-sized databases.The5ooG5tadsoutinteindustrychievingexceptioalsandadsiperformancefunctionalityibility andusability.Itisidelyeploedrosrioctorsludingfance,telecommunicationsrgyaltaredc tion,and manufacture etc.
Product Features
■Ultimate Performance
> The industry-leading Active-Active storage architecture is adopted to achieve load balancing between controllers, eliminate controller performance bottleneck,and improve storage system performance.
> Powered by the Intel multi-core processors and equipped with leading communication link,effectively meet high IOPS and low latency requirements while maximizing storage performanceand elevating thedata processing efficiency of the storage system. By leveraging its intelligent software solutions,suchas InFlashCache, InTier,and InQoS,application performance is significantly improved with less investments.
> Intelligent compression&deduplication,the maximum reduction ratio can reach 5:1,significantly improve the efficiency of space utilization. Intelligent deduplication, to achieve effcient deletion of duplicate data,higher return on equipment investment.
■Flexible Extension
> Supports 2U12,2U25 and 3U48 specification controller enclosures,flexible combination of SAS SSD,SAS HDD and other hard disks,to provide higher performance and larger capacitydatastorage experience.
> Supports 2U12,2U25 and 3U48 specification disk enclosures, which can be cascaded vertically in multiple levels as required to flexibly expand storage space and reduce investment costs.
> The mid-range active storage system supports online scale-out to multi-controller and TB-level cache,allowing customers to linearly increase the storage capacity and performance to meet the demands of rapidly changing businesses.
> Supports the simultaneous use of IP-SAN,FC-SAN, RoCE, NFS,CIFS,and FTP.A set of storage supports multiple application platforms,and the system architecture is simpler to work and manage.
■Stable&Reliable
> The storage system adopts full redundancy architecture and modular design, with all core components being fully redundantto eliminate single point of failure and achieve high availability of the storage system.
> There are multiple data redundancy protection modes,local support for write-time replication,snapshot, clone and incremental backup. Support for intelligent metro,remote copy,3DC and other disaster recovery solutions to ensure business continuity and apply high availability.
> IntelligentRAlD technology,redundant data blocks can be quickly restored, data blocks and hot backup blocks are distributed on all disks.Aftera bad disk appears,all hard disks participate in reconstruction,and the data reconstruction time is shortened to minute level with reducing the risk of RAlD failure and enhancing system reliability.
> Supports online hardware expansion, online firmware upgrade,and online system maintenance to ensure the continuity of the service system.Supports continuous BBU powerfailureprotection for2times,andbusiness isnot interrupted within 2S\~5S,easily respond to risks such as poweroutagesatdatacenters.
■Easier Management
> Graphical interface design:Provides onlinemonitoring of storage performance,capacity,and system status,as well as DMP maintenance wizard for fault events.
> Efficient configuration management: Supports GUl and CLl management operations,supports configuration of multiple role permission control,and realizes efficient management of storage data access permissions.
> IntelligentHeterogeneousVirtualization, heterogeneous storage devices of mainstream storage vendors eliminate platform differences and realize efficient reuse of storage devices;at the same time,enhance data mobility and eliminate data islands,and the unified management of resources is simple and efficient.
> The IntelligentManagement platform can effectively solve IT system operation and maintenance problems,improve operation and maintenance efficiency,reduce operation and maintenance costs,ensure data reliability and availability, and ensure business continuity.
Technical Specifications
| ProductModel | KS5000G5 | |
| Control Enclosure | KS5000G5-MS12(2U12)/MS25(2U25)/MS48(3U48) | KS5000G5-MS12P(2U12)/MS25P(2U25)/MS48P(3U48) |
| Disk Enclosure | JBOD:2U12/2U25/3U48,SAS protocol | |
| Max. Number of Drives (dual-controller) | 1000 | |
| RAID Level | RAID 0/1/ 5/6/10,InRAID 5/6 | |
| CPU | Multiple multi-core CPUs | Multiple multi-core CPUs |
| System Cache (dual-controllr) | 64 GB-256GB | 128 GB- 512 GB |
| Front I/O Card Specifications (dual-controller) | 6 pcs | |
| Front I/O Card Specifications | 16/32GB FC card,1/10/25/100 GB Ethernet NIC,and 25/100 GB RoCE NIC | |
| DRAM Cache Protection | Continuous protectionagainsttwo consecutive BBUpowerfailures,ensuring thatbusiness operationsremainuninterrpted within 2~5 second power interruption | |
| Improved Resource Efficiency | Intellient)e)eo)i IntellgentDeduplicaion(nDedupe),ntelligetVolumeune(une),ntelligenterier),IntelligentHeterogeeous | |
| Data Protection Software | Virtualization (InVirtualization),and IntelligentManagement (InManagement) IntelligentSnapshot(nnapShot),ntellientClone(Inone),InteligentBackup(Backup),IntelligentRemoteCoy (InRemoteCopy),ntelligentMetro(nMetro),IntelligentVdiskMirror (InVdiskMrror),and IntelligentErase (ae) | |
| Key Service Assurance | IntelligentQualityfService (InQoS),IntelligentAutomaticCachePartition(nAutoPartition),andIntellgentFlasCache (InFlashCache) | |
| Dimensions (W*D*H mm, D indicates the depth when installed in the rack) | 2U control enclosure:446.00× 619×87.80 mm (17.56×24.37 ×3.46 in.) 3U control enclosure:447.20 ×920 × 132.00 mm (17.60× 36.22× 5.20 in.) | |
| Weight (without Drive, kg/lbs) | 2U12 control enclosure: 32.8/72.32, 2U25 control enclosure: 27.8/61.29 3U48 control enclosure: 48/105.83 | |
| Max Power of the Power Supply | 2U control enclosure: 850W,3U control enclosure: 1200W | |
| Input Voltageof thePowerSuppyAC:AC220VorAC110Vduallve wire(180-264VAC,10A,50-60Hz,IEC60320-C14) DC:DC 240V(240-320VDC,IEC60320-C14) | ||
| Storage Temperature | -40C to 70C(-40°Fto158F) (excluding BBUand HDDin the server),0°Cto 70°C (32°Fto158F) is recommended | |
KAYTUS
KAYTUS Storage KS3000G7-F
Entry-level High-performance Centralized All-flash Storage
Product Overview
TheKS30OG7-FStoragePlatformisanentry-levelcentralizedal-flashstoragesolutiondesignedforenterprise,healtcare andeducationalapplicationenvironments.Itadoptsanewalflasharchitecture,withinteligentalgorithmsoptimizingdata readandwriteprocessesend-to-end,resulting inhighersystemperformanceandlower latency.Theplatformofersawide rangeofflexiblesoftwarefeatures,significantlyenhancingdatareadandwriteeficiencyandcontinuity.Itsupportsvarious networkenvironmentsincdingI-SAN,FC-SAN,andRoCE,providingasy-to-usestorageoperationandanagemtlf abovemakes KS3000G7 Storage Platform fully meet thedata storage needsof smalltomedium-sized databases for OLTP/OLAP,ERP/CRM,VDl,ficeOA,dsasterrecovery,bckup,ideostorage,andotherbusinesserio.
Product Features
■ Leading Architecture
> The industry-leading Active-Active storage architecture is adopted to achieve load balancing between controllers,eliminate controller performance bottleneck,and improve system performance.
> The storage system supports the configuration of volumes with orwithout ownership.The volume without ownership is combined with self-developed multi-path software to achieve load balancing of multiple controllers and better system performance.
> The system adopts full redundancy architecture and modular design,with all core components being fully redundant to eliminate single pointof failureand achieve high availability of the storage system.
> The core components are supported by PCle4.0,which doubles the link bandwidth of the whole machine and doubles the IOPS of the storage system.
> Supports the simultaneous use of IP-SAN,FC-SAN,RoCE and other protocols.A set of storage supports multiple application platforms,and the system architecture is simpler to work.
■ Ultimate performance
> With the newall-flasharchitecture,intelligentalgorithms are used to optimize data read and write end-to-end, and operations such as data compression,strip aggregation,and overall writing are implemented to effectively reduce SSD write amplification and the performance of storage system is improved significantly;usingwear balancing and anti-wear technology, data is written to the SSD more evenly,effectively extending the average usage time of the SSD; support global garbage collection technology and Trim instructions,reduce the relocation ofinvalid data in the SSD disk,extend the life of the SSD, and significantly improve system performance.
> IntelligentCompression,the maximum compression ratio canreach5:1,significantly improve the efficiency of space utilization; Intelligent Deduplication,to achieve efficient deletion of duplicate data, higher return on equipment investment.
■Stable&Reliable
> There are multiple data redundancy protection modes, local support forwrite-time replication,snapshot, clone and incremental backup;support for IntelligentMetro, IntelligentRemoteCopy,3DC and otherdisaster recoverysolutions to ensure business continuity and apply high availability.
> IntelligentDistributedRAlD technology,redundant data blocks can be quickly restored,data blocksand hot backup blocks are distributed on all hard disks.Aftera bad disk appears,all hard disks participate in reconstruction,and the data reconstruction time is shortened to minute level with reducing the risk of RAID failure and enhancing system reliability.
> Intelligent Encryption,effectively prevent data from being illegally accessed or leakedinstorage,transmission,to ensure thesecurity and integrity of data; intelligent data erase, one-click intelligent erase of obsolete data,ensure secure use of critical and sensitive data.
> Supports online hardware expansion,online firmware upgrade, and online system maintenance to ensure the continuity of the service system;supports continuous BBU power failure protection for2 times,and business is not interrupted within 2S\~5S,easily respond to risks such as power outages at data centers.
■Easier Management
> Graphical interface design: Provides online monitoring of storage performance,capacity,and system status,as well as DMP maintenance wizard for fault events.
> Efficient configuration management: Supports GUl and CLl management operations,supports configuration of multiple role permission control,and realizes efficient management of storage data access permissions.
> IntelligentHeterogeneousVirtualization,heterogeneous storage devices of mainstream storage vendors eliminate platform differences and realize efficient reuse of storage devices;at the same time,enhance data mobility and eliminate data islands,and the unified management of resources is simple and efficient.
> The IntelligentManagement platform can effectively solve IT system operation and maintenance problems, improve operation and maintenance efficiency,reduce operation and maintenance costs,ensure data reliability and availability, and ensure business continuity.
Technical Specifications
| Product Model | KS3000G7-F |
| Controller Enclosure | KS3000G7-F-MS25 (2U25) |
| Disk Enclosure | JBOD:2U25/3U48,SAS protocol JBOF:2U25,NVMe protocol |
| Max. Number of Disks(dual-controller) 601 | |
| RAID Level | InRAID 5/6 |
| CPU | Multiple multi-core PCIE4.0 CPUs |
| System Cache (dual-controller) | 128 GB-512GB |
| Front Interface Cards (dual-controller) 8 pcs (PCIE4.0) | |
| Front I/O Card Specifications | 16/32/64 Gb FC card,1/10/25/100 Gb Ethernet NIC,and 25/100 Gb RoCE NIC |
| Hot-Swap Modules | Controller,disk,BBU,power supply,FCcard,Ethernet NIC, NVMe card,SAScontroller cardand RoCE NC |
| DRAM Cache Protection | Continuous protection against two consecutive BBU power failures,ensuring that business operations remain uninterrupted within 2~5 second power interruption |
| Improved Resource Efficiency | Intelligentnn),ntelligenttrutedAD(nAD),tellintigation(ration),ntelligentCoo (InCompression),IntelligentDeduplication(nDedupe),IntelligentVoumeTune (nune),IntelligentHeterogeou Virtualization (InVirtualization), IntelligentManagement (InManagement) |
| Data Protection Software | Intelligentnapshot (naphot),Intelligentone(none),IntellgentBackup(Backup),IntellientRemoteCopy (InRemoteCopy),IntelligentMetro (InMetro),IntellientEncryption (nncryption),and IntellgentErase (nrase) |
| Key Service Assurance | Intelligent Quality of Service (InQoS)and Intelligent Automatic Cache Partition (InAutoPartition) |
| Dimensions (W*D*H mm, D indicates the depth when installed in the rack) | 447.00 × 741.30× 87.00 mm (17.60× 29.19 × 3.43 in.) |
| Weight (without Drive, kg/lbs) | 29.2/64.37 |
| Max Power of the Power Supply | 800W |
| Input Voltage of the Power Supply | AC: AC 220 Vor AC 110 Vdual live wire (180-264 VAC,10 A,50-60 Hz, IEC60320-C14) DC:DC 240V(180-320VDC,IEC60320-C14) |
KAYTUS
KAYTUS Storage KS3000G7
Entry-level Exceptional Cost Performance Centralized Hybrid Flash Storage
Product Overview
TheKS30G7StoragePlatformisanentry-levelcentralizedhybridflashstoragedesignedforenterprise,healthcareand educationalappicationenvironments.Itfeaturesflexibleandrichsoftwarecapabliestoenhancedatareadandwriteeficiencyandcontinuity.Theplatformsupportsvariousnetworkenvironmentsincluding I-SAN,FC-SAN,andRoCE,offering easy-to-usestorage operationandmanagement.Allofabove makes KS30o0G7Storage Platformfullymeetthedatastorage needsofsmallandmedium-sizedatabasesforOL/OAPDiceOA,videostorage,disasterrecoveryndbackup scenarios.
Product Features
■ Leading Architecture
> The industry-leading Active-Active storage architecture is adopted to achieve load balancing between controllers, eliminatecontrollerperformancebottleneck,and improve system performance.
> The storage system supports the configuration of volumes with or without ownership.The volume without ownership is combined with self-developed multi-path software to achieve load balancing of multiple controllers and better system performance.
> The system adopts full redundancy architecture and modular design,with all core components being fully redundant to eliminate single point of failure and achieve high availability of the storage system.
> The core components are supported by PCle4.0,which doubles the link bandwidth of the whole machine and doubles the IOPS of the storage system.
■Flexible Extension
> Supports 2U12 and 2U25 specification controller enclosures, flexible combination of SAS SSD,SAS HDD and other hard disks, to provide higher performance and larger capacity data storage experience.
> Supports 2U12,2U25 and 3U48 specification disk enclosures, whichcanbecascaded verticallyinmultiple levelsas required to flexibly expand storage space and reduce investment costs.
> IntelligentCompression,the maximum compression ratio can reach 5:1,significantly improve the efficiency of space utilization;lntelligent Deduplication,to achieve efficient deletion of duplicate data, higher return on equipment investment.
> Supports the simultaneous use of IP-SAN,FC-SAN,RoCE and other protocols.A set of storage supports multiple application platforms,and the system architecture is simpler to work.
■Stable&Reliable
> There are multiple data redundancy protection modes, local support for write-time replication,snapshot,clone and incremental backup;support for IntelligentMetro, IntelligentRemoteCopy,3DC and otherdisasterrecoverysolutions to ensure business continuityand apply highavailability.
> IntelligentDistributedRAlD technology,redundant data blocks can be quickly restored,data blocks and hot backup blocks are distributed onall hard disks.Aftera bad disk appears,all hard disks participate in reconstruction,and the data reconstruction time is shortened to minute level with reducing the risk of RAlD failure and enhancing system reliability.
> Intelligent Encryption,effectively prevent data from being illegally accessed or leaked instorage,transmission,to ensure the security and integrity of data; intelligent data erase,one-click intelligent eraseofobsoletedata,ensure secure use of critical and sensitive data.
> Supports online hardware expansion,online firmware upgrade,and online system maintenance to ensure the continuity of the service system; supports continuous BBU power failure protection for2 times,and business is not interruptedwithin2S\~5S,easily respond to riskssuchas power outagesat data centers.
■Easier Management
> Graphical interface design: Provides online monitoring of storage performance,capacity,and system status,as well as DMP maintenance wizard for fault events.
> Efficient configuration management: Supports GUl and CLI management operations,supports configuration of multiple role permission control,and realizes efficient management of storagedataaccesspermissions.
> IntelligentHeterogeneousVirtualization,heterogeneous storage devices of mainstream storage vendors eliminate platform differencesand realize efficient reuse of storage devices;at the same time,enhancedatamobilityandeliminatedata islands, and the unified management of resources is simple and efficient.
> The IntelligentManagement platform can effectively solve IT system operation and maintenance problems,improve operationandmaintenanceefficiency,reduceoperationandmaintenance costs,ensure data reliabilityand availability,and ensure business continuity.
Technical Specifications
| Product Model | KS3000G7 | |
| Controller Enclosure | KS3000G7-MS12 (2U12) | |
| Disk Enclosure | JBOD: 2U12/2U25/3U48,SAS protocol JBOF: 2U25,NVMe protocol | |
| Max. Number of Disks(dual-controller) 601 | ||
| RAID Level | InRAID 5/6 | |
| CPU | Multiple multi-core PCIE4.0 CPUs | |
| System Cache (dual-controller) | 128 GB - 512 GB | |
| Front Interface Cards (dual-controller) | 8 pcs (PCIE4.0) | |
| Front I/O Card Specifications | 16/32/64 Gb FC card,1/10/25/100 Gb Ethernet NIC,and 25/100 Gb RoCE NIC | |
| Hot-Swap Modules | Controller,disk,BBU,powersupply,FCcard,Ethernet NIC, NVMe card,SAS controler cardand RoCE NIC | |
| DRAM Cache Protection | Continuous protection against two consecutive BBU power failures,ensuring that business operations remain uninterrupted within 2~5 second power interruption | |
| Improved Resource Efficiency | IntelligentTin(in),ntelligentstributedD(RAD),Intellgntigration(igration),ntelligentCo (InCompression),IntelligentDeduplication (nDedupe),IntelligentVolumeTune (Inune),IntelligentHeterogeneos Virtualization (InVirtualization),and IntelligentManagement (InManagement) | |
| Data Protection Software | IntelligentSnapshot (naphot),IntelligentCone(nlone),ntellientBackup (Backup),IntelligentRemoteoy (InRemoteCopy),IntelligentMetro (nMetro),IntellientEncryption (nEncryption),and Intellientrase (rase) | |
| Key Service Assurance | Intelligent Quality of Service (InQoS) and IntelligentAutomaticCachePartition (InAutoPartition) | |
| Dimensions (W*D*Hmm,Dindicates the depth when installed in the rack) | 447.00×767.15× 87.00 mm (17.60×30.20×3.43 in.) | 447.00× 741.30×87.00 mm (17.60×29.19×3.43 in.) |
| Weight (without Drive, kg/lbs) | 31/68.34 | 29.2/64.37 |
| Max Power of the Power Supply | 800W | |
| Input Voltage of the Power Supply | AC:AC 220 Vor AC 110V dual live wire (180-264 VAC,10A,50-60 Hz,IEC60320-C14) DC:DC 240V(180-320 VDC,IEC60320-C14) | |
KAYTUS
KAYTUS Storage KS2000G7
Entry-level Cost-effective Centralized Hybrid Flash Storage
Product Overview
KS2000G7StoragePlatformisanentry-levelcentralizedhybridflashstoragedesignedforenterprise,healthcare,andeducationalapplicationenvironments.Itfeaturesflexibleandrichsoftwarecapabies toenhancedatareadandwriteefciencyand continuity.Theplatformupportsvariousnetworkenvironmentsinluding I-SAN,FC-SAN,andRoCE,oferingeasytose storage operationand management.Allof abovemakes KS2Oo0G7Storage Platform fully meetthedata storageneedsof small and medium-sizeddatabases,oficeOAsystems,videostorage,disasterrecoveryandbackupscearios.
Product Features
■ Leading Architecture
■Flexible Extension
>The industry-leading Active-Active storage architecture is adopted to achieve load balancing between controllers, eliminatecontrollerperformancebottleneck,and improve system performance.
> The storage system supports the configuration of volumes with or without ownership.The volume without ownership is combined with self-developed multi-path software to achieve load balancing of multiple controllers and better system performance.
> The system adopts full redundancy architecture and modular design,with all core components being fully redundant to eliminate single point of failure and achieve high availability of the storage system.
>The core componentsaresupported byPCle4.0,which doubles the link bandwidth of the whole machine and doubles the IOPS of the storage system.
> Supports 2U12 and 2U25 specification controller enclosures, flexible combination of SAS SSD,SAS HDD and other hard disks, to provide higher performanceand larger capacity data storage experience. > Supports 2U12,2U25 and 3U48 specification disk enclosures, which can be cascaded vertically inmultiple levels as required to flexibly expand storage space and reduce investment costs. > Supports the simultaneous use of IP-SAN,FC-SAN,RoCE and other protocols.A set of storage supports multiple application platforms,and the system architecture is simpler to work.
■Stable&Reliable
> There are multiple data redundancy protection modes, local support for write-time replication,snapshot,clone and incremental backup;remote support for synchronous or asynchronous remote copy to ensure business continuity and apply high availability.
> IntelligentDistributedRAlD technology,redundant data blocks can be quickly restored,data blocks and hot backup blocks are distributed onall hard disks.Aftera bad disk appears,all hard disks participate in reconstruction,and the datareconstruction time isshortened tominute level with reducing the risk of RAlD failureand enhancing system reliability.
> Supports online hardware expansion,online firmware upgrade,and online system maintenance to ensure the continuity of the service system; supports continuous BBU power failure protection for2 times,and business is not interrupted within { 2 } { S } { ~ } 5 { S } , easily respond to risks such as poweroutagesatdatacenters.
■Easier Management
> Graphical interface design: Provides online monitoring of storage performance,capacity,and system status,as well as DMP maintenance wizard for fault events.
> Efficient configuration management: Supports GUl and CLI management operations,supports configuration of multiple role permission control,and realizes efficient management of storagedataaccesspermissions.
> IntelligentHeterogeneousVirtualization,heterogeneous storage devices of mainstream storage vendors eliminate platform differencesand realize efficient reuse of storage devices;at the same time,enhancedatamobilityandeliminatedataislands, and the unified management of resources is simple and efficient.
>The IntelligentManagement platformcan effectivelysolve IT system operation and maintenance problems,improve operationandmaintenanceefficiency,reduceoperationandmaintenance costs,ensure data reliabilityand availability,and ensure business continuity.
Technical Specifications
| Product Model | KS2000G7 | |
| Controller Enclosure | KS2000G7-MS12 (2U12) | KS2000G7-MS25 (2U25) |
| Disk Enclosure | JBOD:2U12/2U25/3U48,SAS protocol | |
| Max. Number of Disks(dual-controller) 409 | ||
| RAID Level | InRAID 5/6 | |
| CPU | Multiple multi-core PCIE4.0 CPUs | |
| System Cache (dual-controller) | 64 GB- 512 GB | |
| Front Interface Cards (dual-controller) | 8 pcs (PCIE4.0) | |
| Front I/O Card Specifications | 16/32/64 Gb FC card,1/10/25/100 Gb Ethernet NIC,and 25/100 Gb RoCE NIC | |
| Hot-Swap Modules | Controller, disk, BBU,power supply, FC card, Ethernet NIC and SAS controller card | |
| DRAM Cache Protection | Continuous protection against two consecutive BBU power failures,ensuring thatbusiness operations remain uninterrupted within 2~5 second power interruption | |
| Improved Resource Efficiency | IntelligentTin(n),ntelligentstuted(nAD),tellgentgaion(gaion)ntelligentVu (InTune), IntelligentHeterogeneousVirtualization (InVirtualization), IntelligentManagement (InManagement) | |
| Data Protection Software | IntelligentSapshot (naphot),tellntoning(nlone),ntelligentackup(nBackup),Intelligentmotey (InRemoteCopy),and Intelligent Erase (InErase) | |
| Key Service Assurance | Intelligent Quality of Service (InQoS)and Intelligent Automatic Cache Partition (InAutoPartition) | |
| Dimensions (W*D*H mm, D indicates the depth when installed in the rack) | 447.00 × 767.15× 87.00 mm (17.60× 30.20× 3.43 in.) | 447.00 ×741.30× 87.00 mm (17.60× 29.19 × 3.43 in.) |
| Weight (without Drive,kg/lbs) | 31/68.34 | 29.2/64.37 |
| Max Power of the Power Supply | 800W | |
| Input Voltage of the Power Supply | AC: AC 220 Vor AC 110V dual live wire (180-264 VAC,10A,50-60 Hz,IEC60320-C14) DC:DC240V(180-320VDC,IEC60320-C14) | |