Document Part No.
551401 Revision B
Data Sheet
C-Series M1-Sensor Analog
Magnetostrictive Linear Position Sensors
Temposonics®
Absolute, Non-Contact Position Sensors
C-Series
M1-Sensor Analog
Temposonics® C-Series
Measuring Length 72…250 mm
Document Part No.
551401 Revision B
The sensor is a function of the customer requirements according to the application, and considering the environment, environmental influences, including
EMC protection effects.
• Contactless measurement – entirely wear-free
• Low weight – ideal for small portable OEM products
• Cost-efficient
• Space-saving
• Low energy requirement – can be operated from 5 VDC or 12 VDC supply
• No need for periodic re-adjustment
• Available with various position magnets
• Optional: direct or inverse analog output signal
• Optional: assignment of output signal to measuring length
Magnet field of
current pulse
Magnet field of
position magnet
Mechanical
strain pulse
Movable position magnet
Magnetostrictive
sensing element
(waveguide)
Current
interrogation pulse
Strain (torsion) pulse converter
Measuring technology
The absolute Temposonics linear position sensors are based on the
proprietary magnetostrictive measuring principle. This combines various
magneto-mechanical effects and uses the physically exact velocity
measurement of an ultrasonic wave (torsion pulse in its sensor element) for
position detection. The sensor-integrated signal processing converts the
measured values directly into commercially available outputs. The non-contact
principle - an external moving magnet marks the position - eliminates the
problems of wear, noise and false signals and guarantees best durability
without recalibration.
61 15.5 Measuring length 27.5
Ø 8
Null
zone
Zero and measuring length are
referred to the magnet center
M14x1.5
DIN ISO 6149-2
M12x1 for connection line
11 Magnet
Standard holding ring
(Float)
SW 27
Technical data
Input
Measured value: Position
Stroke length: 72, 109, 128, 148, 162, 186, 194, 217, 250 mm
Ausgang
Voltage: 0.1 - 4.9 VDC
Resolution: analog output signal
Signal without magnet: not specified
Features: At 5 VDC operating voltage output is ratiometric to operating voltage
Accuracy
Linearity: ±0.15 mm by means of magnet 401842, between 5 % and 95 % of stroke length
Zero tolerance: ±1 mm
Hysteresis: ±25 µm
Repeatability: ±25 µm
Temperature coefficient: ±0.005 % per °C
Update time: 500 Hz (2 ms)
Operation conditions
Operating temperature:
Storage temperature:
-40 °C…+75 °C (+105 °C after consulting Temposonics)
-40 °C…+85 °C
Pressure
up to 2500 m altitude
Operating pressure: Ø 8 mm rod
Pn: 250 bar, Pmax: 325 bar
IP Protection
IP69K (plugged)
6 - DIN 40 050 Part 9 – Protection against foreign bodies: Dustproof, complete protection against contact
9K - DIN 40 050 Part 9 – Protection against water: At high pressure / steam cleaning, connected condition
Environmental testing
Shock test: IEC-68-2-27
100 g (11 ms) –> Single hit
50 g (11 ms) 1000 Shocks per axis
Vibration test: IEC 68-2-6 (10…2000 Hz) 15 g Sinus (resonance frequencies excluded)
EMC-test: Electromagnetic emission EN 61000-6-4
CISPR 16-2-3 – Disturbance field strength (measuring distance 3 m)
CISPR 16-2-1 – Disturbance current (DC voltage supply)
Electromagnetic immunity EN 61000-6-2
EN 61000-4-2 – Electrostatic discharge (ESD)
EN 61000-4-3 – Radiated electrosolenoidic radio frequency, free radiated
EN 61000-4-4 – Electrical fast transient (Burst)
EN 61000-4-5 – Surge
EN 61000-4-6 – Conducted radio-frequency, line guided
EN 61000-4-8 – Power frequency solenoidic field
Form factor, material
Housing: Stainless steel 1.4305 (AISI 303)
Protective tube: Stainless steel 1.4306 (AISI 304L)
Electrical connection
Supply voltage: CS: 5 VDC (tolerance range 4.75 - 5.5 VDC), CM: 12 VDC (tolerance range 9 - 15 VDC)
Max. power consumption: max. 40 mA
Output load: analog: > = 10 kΩ
Overvoltage protection: CS: up to 19 VDC short term
CM: up to 29 VDC short term
Polarity protection: VDC - GND
Operating voltage quality: CS: 5 VDC CM: 12 VDC
Load control: ±0.1 % ±0.15 %
Grid control: ±0.05 % ±0.05 %
Ripple: < 50 mVpp < 100 mVpp
Mechanical connection
Temposonics® C
M1-Sensor Analog
I 2 I
for Ua at Ia 0 - 100 %
for Ua at Uemin - Uemax
Pin Signal
1 Supply voltage
2 Output voltage
3 DC Ground
4
1 2
4 3
The sensor is a function of the customer
requirements according to the application,
and considering the environment, environmental
influences, including EMC protection effects.
Accessories
Ring magnet
Description Article No. Inside Ø Outside Ø Width
Ring magnet 19.3 mm 400 424 19.3 mm 28 mm 4.9 mm
Ring magnet 13.5 mm 254 012 13.5 mm 20 mm 10.5 mm
Float
Description Article No. Inside Ø Outside Ø Width
Float 1 201 611 9.5 mm 28.6 mm 30 mm
Temposonics® order code
C A V M 1
Series
Sensor model C
Supply voltage
S - 5 VDC
M - 12 VDC
Measuring length
72, 109, 128, 148, 162, 186, 194, 217, 250 mm
Output
V - Analog
Housing
M1 - IP69K housing
Example:
CM186AVM1 Sensor model C - Supply voltage 12 VDC - Measuring length 186 mm - Output analog - IP69K housing
Magnet and float options (An additional quantity of 1 unit per sensor should be ordered)
Describtion Function Articel No.
Ring magnet 19.3 mm optional after approval for applications requiring a magnet with more clearance 400 424
Ring magnet 13.5 mm optional after approval for applications requiring a magnet with more clearance 254 012
Float 1 with magnet optional after approval for applications 201 611
Temposonics® C
M1-Sensor Analog
I 3 I
ID
Width
N S
OD
ID
WidthN S
OD
Ø 9.5
Ø 26.9
30
Ø 28.6
201611
Application examples:
The target in customer solutions is a high degree of efficiency and synergy to the product. During the design phase measurements need to be taken which
enable the product to meet customer requirements suitable for the application.
In this respect, close cooperative partnership between the customer and Temposonics is desirable.
All constructive measures relating to operating parameters (vibration, temperature and ESD) require consultation with Temposonics. This also includes
the CE marking of components used for installation.
Level measurement in medical technology
An analyser for immunodiagnostics applications uses magnetostrictive level sensors in containers to monitor the
levels of consumables and of the collected waste products of the analysis. Through continuos measurement, it is
always known how much fluid is in the containers. This enables continuous reloading without interruption of the
analysis and anticipatory planning.
Increased dosing accuracy, reduced consumption
The dosing accuracy during preparation of damping solution and precise control of the IPA concentration are of
considerable importance for the production and process stability in printing systems. The continuous discussion
relating to the toxic load of the ambient air at work places and the need for cost reduction in printing companies
also requires further reduction of isopropyl alcohol in the damping solution. The Temposonics® OEM-sensor plays
an important part for dosing of damping solutions and thus for decreasing the overall costs.
Position feedback in process measurement and control systems
The valve position feedback combines well-proven sensor technology and state-of-the-art design for optimized
applications. Our development activity focused on the requirements and wishes expressed by our customers in
the liquid processing industry.
In addition to safe control and monitoring of all functions of process valves in breweries, dairies, facilities for
production of fruit juice and production plants in the pharmaceutical industry, the C-Series provides a high degree
of efficiency.
Position feedback in steering systems
The customer-specific sensors are used to monitor the steering position of rear drives and to provide position
feedback. Based on the linear C-series position sensor, these sensors are equipped with a special housing, which
was developed by the end user and realized by Temposonics. The sensors measure the stroke of steering
cylinders on the port side and the bow side. Typically installed in multi-engine boats, the boat control system
uses the sensor signal to permit control of the boat movement using a joystick: A solution termed “Steer-ByWire”.
Cabin suspension
To reduce the human vibration, directive 2002/44/EC (human vibration directive) of the European Union has been
implemented into national law in March 2007. This directive defines binding limit values (reference period of
8 hours < value 0.5 m/s²) for the hand-and-arm area as well as whole-body vibration values, which must not be
exceeded.
These limit values are met by effectively reducing the induced vehicle vibration using C-series position sensors in
a cabin suspension system. The cabin suspension system permits reduction of the accelerations mainly in the Z
axis. Due to this reduction, the vibration load acting on the driver is alleviated considerably, without affecting
driving experience and operability.
MTS Sensor Technologie
GmbH & Co. KG
MTS Automotive Sensors GmbH
Auf dem Schüffel 9
58513 Lüdenscheid, Germany
Tel. + 49-23 51-95 87 0
Fax + 49-23 51-5 64 91
E-Mail: info@mtssensor.de
www.mtssensor.de
MTS Systems Corporation
Sensors Division
3001 Sheldon Drive
Cary, N.C. 27513, USA
Tel. + 1-919-677-0100
Fax + 1-919-677-0200
E-Mail: sensorsinfo@mts.com
www.mtssensors.com
Document Number: 551401 Rev. B (EN) 09/2013
© 2021 Temposonics, LLC – all rights reserved. Temposonics, LLC and Temposonics GmbH & Co. KG are subsidiaries of
Amphenol Corporation. Except for any third party marks for which attribution is provided herein, the company names and product
names used in this document may be the registered trademarks or unregistered trademarks of Temposonics, LLC or Temposonics
GmbH & Co. KG. Detailed trademark ownership information is available at www.temposonics.com/trademarkownership.
temposonics.com
UNITED STATES
Temposonics, LLC
Americas & APAC Region
3001 Sheldon Drive
Cary, N.C. 27513
Phone: +1 919 677-0100
E-mail: info.us@temposonics.com
GERMANY
Temposonics GmbH & Co. KG
EMEA Region & India
Auf dem Schüffel 9
58513 Lüdenscheid
Phone: +49 2351 9587-0