AINEXT STATION
IntelligentRegulation of Indoor Temperature,Humidityand Air Quality and Strong Performance
TheNextStationofWonderfulAir
Almulti-dimensional regulationofindoor temperature,humidity andairquality
SmartEyeAl technology 汇: Whole-house airpurification
Whole-house
sensing for
improvedcomfort
Skeleton motor-powered compressor and EVl technology for more powerful performance
s-30°C under 米 s55°CGunder lowtemperatures hightemperatures
F Anti-freezing through waterpump Whenthesystemwater temperatureistoolow,thewater pumpstartsautomaticallyto preventfreezingand enable circulation
Anti-freezing through auxiliaryheater
Whenthewatertemperature
doesnotreachthesafety threshold,theauxiliary
heaterstartsautomaticallyto preventfreezing
Anti-freezing through unitheating
Whenthewatertemperatureis
lowerthanthesafetythreshold,
heatingstartsautomaticallyto
preventfreezingandenable circulation
Triune ion cluster for whole-area purification and fresh air containing negative oxygen ions for better user experience
TICA Trinity
OH free radical Sterilizationiecionrmlde removal,andodorelimination
Negative oxygen ion Freshairforenhancedhealth
Activecation Dustremovalandhaze preventionforallergyprevention
Eliminating 12 air-related health risks through one system
8
CO.concentration ≤1000 ppm At least2whole-house air replacements per hour
PM2.5concentration≤35ug/m³
Formaldehydeconcentration≤0.08mg/m3
TVOCconcentration≤0.6mg/m³
△
Noise in.livingroom≤40dB Noise in bedroom ≤20 dB (night)
Multi-dimensional interactions For better air quality
3D smart spoiler to avoid direct air blowing
IPLV up to 4.95, 30% higher the national EEl level 1 Low carbon and green life
PERT high-conductivity material Double heat
Operatingcostoffloor
heatingreducedbyupto 50%winter VS
Heating Operating Heating Operating
capacity cost capacity cost
Traditional wall-mounted Our system gasboilers
Rapid humidification/ dehumidification/oxygen generation for improved comfort
:
Dust removaland haze prevention Dust/Miteremovalrate>94.75%/h PM2.5primaryfilterefficiencyupto99.1%
A
Sterilizationandmold prevention forhighercleanness Bacterial/viruspurificationefficiency>99.99% Moldpreventionclass0 (optimal) \*CertifiedbyauthoritiessuchasGS,TUVandGW
Moisturizedandskin-friendly Deepdehumidification:7.8kg/h\* Stronghumidification:1.8kg/h\* \*Formodelswithanairflowof500m³/h
| Model | Unit | TDN50-7.8AL/R |
| Airflow | m³/h | 500 |
| ESP | Pa | 120 |
| Powersupply | 220 V~ 50 Hz | |
| Nominaldehumidificationcapacity | (kg/h) | 7.8 |
| Nominaldehumidification power | kW | 1.1 |
| Nominaldehumidificationcurrent | A | 5.2 |
| Humidityratioofsuppliedairincoolingmode | g/kg | 8 |
| Humidificationcapacity | (kg/h) | 1.8 |
| Chargedrefrigerantamount | R410A/700g | |
| Maximumoperating powerof theunit | kW | 2.1 |
| Maximumoperatingcurrentoftheunit | A | 10.2 |
| Maximumoperatingpressureoftheheatexchanger(waterside/refrigerantside) | MPa | 0.5/4.2 |
| Designinletwatertemperatureonthewaterside | °℃ | 16/21 |
| Noise | dB (A) | 48 |
| Weight | kg | 86 |
| Dimensions (Length *Width *Height) | mm | 980×660×400 |
| IPrating | IPXO | |
| Protectionagainst electric shock | Classl | |
Infinity Main Unit Specifications
Notes:TheapplicablestandardisGB/T18430.2-2016.
| Mainunit | TECA 120BEDNC | TECA 140BEDNC | TECA 160BEDNC | TECA 180BERNA | TECA 200BERNA | TECA 220BERNA | TECA 255BETNA | TECA 285BETNA | TECA 335BETNA | |
| Powersupply | 220V~50Hz | 380V3N~50 Hz | ||||||||
| Nominal cooling 7℃ kW capacity | 12 | 14 | 16 | 18 | 20 | 21 | 25.5 | 28.2 | 32 | |
| Ratedpowerinput (kW) 3.77 | 4.68 | 5.4 | 6.04 | 6.89 | 7.72 | 7.5 | 8.41 | 10.6 | ||
| COPC(kW/kW) 3.18 | 2.99 | 2.96 | 2.98 | 2.9 | 2.72 | 3.4 | 3.35 | 3.02 | ||
| Nominal heating 45℃ capacity | kW | 14 16 | 18 | 20 | 22 | 22.5 | 27 | 30 | 34 | |
| Ratedpowerinput (kW) 4.09 | 4.73 | 5.37 | 6.1 | 6.77 | 7.25 | 7.4 | 8.33 | 9.99 | ||
| COPh (kW/kW) | 3.42 | 3.38 | 3.35 | 3.3 | 3.25 | 3.1 | 3.65 | 3.6 | 3.4 | |
| IPLV(C) 4.6 | 4.5 | 4.3 | 4.5 | 4.4 | 4.3 | 4.95 | 4.94 | 4.6 | ||
| Circulatingwaterflow (m³/h) | 2.06 | 2.41 | 2.75 | 3.1 | 3.44 | 3.61 | 4.39 | 4.9 | 5.5 | |
| Pumptype (Formodelswith waterpumps) | Variablefrequencycannedpump | Centrifugalchiller | ||||||||
| Maximum total | 7.3 | 7.3 | 7.3 | 10 | 10 | 10 | 14.5 | 17 | 17.5 | |
| Maximumoperating current(A) | 34 | 34 | 34 | 16.5 | 16.5 | 16.5 | 24 | 26 | 27 | |
| Applicable ambient | Cooling operation 5to55 | 5to55 | 5to55 | 5to55 | 5to55 | 5to55 | -5to55 | -5to55 | -5to55 | |
| temperature (℃) | operation -25to43 Heating | -25to43 | -25to43 | -25to43 | -25to43 | -25to43 | -25to55 | -25to55 | -25to55 | |
| Refrigerant/Charge quantity | R410A/2.80kg | R410A/3.85kg | R410A/6.30kg | |||||||
| Operatingsound (dB(A)) | 55 55 | 56.5 | 57 | 57 | 57.5 | 56 | 58 | 59 | ||
| Unit externallift (mH2O)* | 10 8.5 | 7 | 7 | 6 | 5 | 21 | 19 | 16 | ||
| Waterpressure drop (kPa)* | 16 20 | 26 | 26 | 30 | 32 | 15 | 20 | 25 | ||
| Water inlet/outlet waterpipe Circulating pipediameter | DN32 | |||||||||
| connection mode | Connection | Externalthread(R1-1/4') | Externalthread(R1-1/4") | |||||||
| Net weight (kg) | 119 | 220(i | ||||||||
| Dimensions (L×W×H) | 980×390×1260 | 1100×470×1550 | ||||||||
Hidwind Indoor Unit Specifications
| Model | TCRS21BYP | TCRS30BYP | TCRS36BYP | TCRS41BYP | TCRS50BYP | TCRS56BYP | TCRH80BYP | ||
| Air flow (m³/h) | High | 340 | 510 | 650 | 750 | 850 | 1020 | 1360 | |
| Medium | 270 | 380 | 487 | 562 | 640 | 780 | 1020 | ||
| Low | 190 | 280 | 325 | 375 | 450 | 560 | 680 | ||
| Cooling capacity (kW) | High | 2.1 | 3.0 | 3.6 | 4.1 | 5.0 | 5.6 | 8.1 | |
| Medium | 1.6 | 2.4 | 2.8 | 3.2 | 4.0 | 4.4 | 6.8 | ||
| Low | 1.2 | 1.8 | 2.1 | 2.4 | 3.0 | 3.3 | 4.9 | ||
| Heatingcapacity(inlet watertemperatureof60℃, kW) | High | 3.4 | 5.1 | 5.8 | 7.1 | 8.3 | 9.3 | 12.8 | |
| Medium | 2.7 | 4.0 | 4.6 | 5.6 | 6.6 | 7.4 | 10.8 | ||
| Low | 2.0 | 3.0 | 3.4 | 4.2 | 4.9 | 5.5 | 7.8 | ||
| Heatingcapacity(inlet watertemperatureof45℃, kW) | High | 2.2 | 3.0 | 3.6 | 4.1 | 5.0 | 5.6 | 8.1 | |
| Medium | 1.7 | 2.4 | 2.9 | 3.3 | 4.0 | 4.5 | 6.6 | ||
| Low | 1.3 | 1.8 | 2.2 | 2.5 | 3.0 | 3.4 | 4.8 | ||
| Power input (W) | High | 21 | 34 | 34 | 42 | 46 | 60 | 87 | |
| Medium | 14 | 19 | 20 | 23 | 24 | ||||
| Low | 9 | 11 | 12 | 13 | 13 | 31 16 | 43 19 | ||
| Coolintentgy CEciency | High 88 | 75 | 87 | 82 | 90 | 75 | 70 | ||
| Heatingenergyefficiencycoefficient (FCCOP) | High 142 | 128 | 141 | 142 | 149 | 124 | 120 | ||
| (Inletwater temperatureof 60°C) Heatingenergyefficiency coefficient(FCCOP) (Inletwatertemperatureof45C) | High 92 | 75 | 87 | 82 | 90 | 75 | 70 | ||
| Noise (dB(A)) | High 27 | 31 | 32 | 33 | 33 | 35 | 48.5 | ||
| Medium | 23 | 25 | 26 | 28 | 28 | 29 | 42 | ||
| Low | 21 | 21 | 22 | 23 | |||||
| Type | 23 | 24 | 33 | ||||||
| Fan Motor | Quantity | 2 | Forward-curvedmulti-bladedoubleinletcentrifugal fan | ||||||
| Type | 2 | 3 | 3 | 4 | 4 | 3 | |||
| Insulationclass | Brushless DC motor | ||||||||
| IPrating | B | ||||||||
| Powersupply | IP41 220V/1N~/50 Hz | ||||||||
| Quantity 1 | 1 1 1 | ||||||||
| Structure type | Efficientdouble-flanged hydrophilicaluminumfinsand copper tubes,expanded intoone | ||||||||
| Heat exchanger Waterresistance | Maximumoperatingpressure (MPa) | 1.6 | |||||||
| Waterinlet/outletpipediameter | Rc3/4 (taper pipe female threaded) | 1.00 1.40 | |||||||
| Waterflow(m³/h) | 0.39 0.52 0.65 | ||||||||
| kPa | 20 30 | 30 30 | 30 40 | 40 | |||||
| Drainpan | Type | EPSblisterdrain pan | Inteitatedetmembly R3/4 | ||||||
| Condensatewaterpipediameter | DN20 | (taperpipemale threaded) | |||||||
| Dimensions(WxD×H) | mm | 810×450×228 | 1030×450×228 | 1250×450×228 1470×462×257 | |||||
| Netweight | kg | 18.5 18.5 | 23 23 | 30.0 30.0 | 30.0 | ||||
Notes:
1.TheairflowvaluesintheabovetablearemeasuredbasedonaninletairDBtemperatureof 20C,aninletairWBtemperatureof15°C,andthefactthatthecoilsarefreeofwater. 2.Thecoolingcapacityvaluesintheabove tablearemeasuredbasedonaninletairDB temperatureof27C,aninletairWBtemperatureof19.5°C,aninletwatertemperatureof7℃, andanoutletwatertemperatureof12C.
3.Theheating capacityvalues intheabove tablearemeasuredbased onan inletairDB temperatureof 21°C under thesamewater flowconditionsas thoseused forcooling. 4.Thenoisevaluesintheabove tablearemeasuredinasemi-anechoicchamberwitha backgroundnoiseof11.5dB(A)inaccordancewithGB/T19232-2019. 5.Theabovetests,ncludingairflow,oolingcapacity,eatingcapacityandoisetetsre basedonunitswithoutanyfilters.
6.Thespecificationsmaybechangedduetoproduct improvement.The parameters indicated ontheunitnameplateshouldprevail.