Switchgear Fittings and Components
Eberre www.vcbbreaker.com
唯一经久不变的价值标准,企业本着最高的诚意以尖端科技挑战命运的机遇,优化生产出更好的产品提供高质量的服务为用户带来优质优价的产品
The only enduring value standard. the enterprise in line with the highest sincerity With cutting-edge technology to challenge the gate of the opportunity. optimize produce a better product Provide high quality service for users with quatity products
COMPANY PROFILE
Eberry Electric Co.,Ltd.is committed to supplying the most reliable high and low-voltage components for power transmission and distribution systems for a long time, as a professional manufacturer with integrated R&D, production,sales, after-sales service, and trade,we are a comprehensive and modern science and technology enterprise covering an area of more than 10 acres, with over 100 employees, including 10 R&D personnel.
Our main products are indoor/outdoor 10-35KV high-voltage vacuum circuit breakers, vacuum load switchesSF6 switches,SF6gas-insulated metal-enclosed switchgear(C-GIS), KYN28A-12 armored movable metal-enclosed switchgear and related accessories. These products are crucial in many major engineering systems in China, and we are a long-term cooperation supplier of the State Grid of China. With nearly 10 years of experience in customizing products and services for overseas markets, we provide tailored solutions for our customers.
Due to advantages such as competitive pricing, fast team response, flexible cooperation programs, and a faithful and honest service concept, our sales have maintained an annual growth rate of over 20% in the past five years.
In the next step, we will increase investment in overseas R&D and sales to improve our brand influence in global market.
PRODUCT CATALOG
Copper Parts Contact Series
001 Tulip Contact Series
003 Static Contact Series
005 VS1 Contact Arm Series
Insulating Components
007 Contact Box Series
014 Bushing Series
024 Bending Plate Series
Earthing Switch
026 EK6-12/31.5 Series Indoor Earthing Switch
028 JN15-12/315(ES1-10/31.5) Earthing Switch
030 JN17-12/40 Earthing Switch
032 JN17-12/50 Earthing Switch
034 JN15-24/31.5 Series Earthing Switch
036 JN22B-40.5/31.5 Series High Voltage Earthing Switch
038 DJN15-31.5 Electric Earthing Switch
040 Chassis Truck
Switchgear Fittings
047 Electric Earthing Switch Controller
056 Guide Rail
058 Earthing Switch Operation Mechanism Interlocking Device
059 Shutter Mechanism
064 New Emergency Opening Device
065 Cabinet Lock & Padlock
075 Cable Clamp & Rubber Retainer & Protective Core
081 Display
083 Wiring Duct
084 Others
EB-5-630A (12 pieces)
| Number of contacts:12 | ![]() | |
| EB-5-630A (24 pieces) | ||
| Number of contacts:24 | ||
![]() | ||
![]() | ||
![]() | ||
| EB-5-1250A (30 pieces) | ||
| Number of contacts:30 | ||
![]() | ||
![]() | ||
![]() | ||
| EB-5-1600A (36 pieces) | ||
| Number of contacts:36 | ||
![]() | ||
![]() | ||
![]() | ||
EB-5-2000A (48 pieces)
Number of contacts:48
EB-5-2500A/3150A (64 pieces)
Number of contacts:64
EB-5-4000A (82 pieces)
Number of contacts:82
630A Static contact outline and installation dimension
| L=72/82 Conventional length | |||
| conventional | economic | c1250A | |
| H | 20 | 15 | 20 |
| D | Φ24 | Φ26 | Φ20 |
1250A Static contact outline and installation dimension
| L=72/82 Conventional length | ||
| conventional | economic | |
| H | 20 | 15 |
| D | Φ24 | Φ26 |
1600A Static contact outline and installation dimension
1600\~2000A Static contact outline and installation dimension
| conventional | economic | |
| H | 20 | 20 |
| D | Φ54 | Φ63 |
| conventional | economic | |
| H | 25 | 20 |
| D | Φ84 | Φ90 |
3150\~4000A Static contact outline and installation dimension
| conventional | economic | |
| H | 25 | 20 |
| D | Φ84 | Φ90 |
BT.12.108.1/108.2VS1-12/630A
Name: Contact arm Material: Copper/Aluminum
BT.12.109.1/109.2VS1-12/1250A
Name: Contact arm Material: Copper/ Aluminum
BT.12.110VS1-12/1 600A
Name: Contact arm Material: Copper
BT.12.111 VS1-12/1600A
Name: Contact arm Material: Copper
BT.12.112VS1-12/2000A
Name: Contact arm Material: Copper
BT.12.113 VS1-12/2000A
Name: Contact arm Material: Copper
BT.12.114VS1-12/2500-3150A
Name: Contact arm Material: Copper
BT.12.115 VS1-12/4000A
Name: Contact arm Material: Copper
CH4-12-208 Contact box(rated current 1600\~2000A),outline and installation dimension
CH9-12-256 Medium M12 side 4-m10 90 °with heat sink contact box,outline and installation dimension
CH1-24-225 Contact box(rated current ≤630A\~1600A),outline and installation dimension
CHJ14-12 Contact Box for Kyn cabinets (1600A-3150A),outline and installation dimension
| A | 48 | 55 | 58 | 63 | 67 |
| B | 12 | 10 | 14 | 9 | 17 |
| A | 65 | 48 | 68 | 88 | 105 | 70 |
| B | 15 | 14 | 18 | 18 | 15 | 15 |
| A | 68 | 48 | 108 | 110 | 125 | 128 | 130 |
| B | 18 | 18 | 18 | 18 | 30 | 18 | 48 |
| A | 68 | 85 | 108 | 128 | 130 | 135 |
| B | 18 | 15 | 18 | 18 | 48 | 45 |
| A | Round 110 | 88 | 108 | 128 | 70 | 68 |
| B | 18 | 18 | 18 | 30 | 18 |
| A | 110 | 110 | 135 | 135 | 135 | 88 | 90 | 135 | 130 |
| B | 18 | 48 | 45 | 60 | 40 | 18 | 40 | 20 | 60 |
TG1-24-175×255X218 Wall bushing,outline and installation dimension
| NO | A | B | C |
| 1 | 372 | 232 | 10 |
| 2 | 392 | 252 | 10 |
| 3 | 382 | 252 | 20 |
Product definition
Central distance between poles
·Rated short -time withstand current(KA)
Rated voltage(KV)
Design No.
Indoor
Earthing switch
Introduction
The EK6-12/31.5 series indoor earthing switch is an advanced design, developed as an improvement over the ES1 type. It is suitable for 3\~12KV, three-phase, 50(60)Hz power systems. Serving as an earthing protection device, it is widely applicable in various types of high-voltage switchgear. The product complies with GB1985-2004 and IEC129 standards.
Working condition
Ambient temperature:-10℃-+40℃;
Altitude:≤1000m;
Relative humidity: Daily average≤95%, Monthly average≤90% Earthquake intensity:≤8 degree;
Dirtiness degree: II.
| No. | Item | Unit | Data | |
| 1 | Rated voltage | KV | 12 | |
| 2 | Rated short time withstand current | KA | 31.5 | |
| 3 | Rated short circuit withstand time | S | 4 | |
| 4 | Rated short circuit making current | KA | 80 | |
| 5 | Rated peak withstand current | KA | 80 | |
| 6 | Rated insulation level | 1min power frequency withstand voltage | KV | 42 |
| Lightning Impulse withstand voltage | 75 | |||
| 7 | Mechanical life | TIMES | 2000 | |
| Specification | E | F | G | H | D | C |
| EK6-12/31.5-165 | 165 | 75 | 160 | 565 | 426 | |
| EK6-12/31.5-180 | 180 | 75 | 160 | 595 | 456 | |
| EK6-12/31.5-200 | 200 | 75 | 160 | 635 | 496 | |
| EK6-12/31.5-210 | 210 | 75 | 160 | 655 | 516 | |
| EK6-12/31.5-220 | 220 | 75 | 160 | 675 | 536 | |
| EK6-12/31.5 230 | 230 | 75 | 160 | 695 | 556 | 96 |
| EK6-12/31.5-250 | 250 | 75 | 160 | 735 | 596 | 96 |
| EK6-12/31.5-275 | 275 | 75 | 185 | 810 | 646 | 96 |
Please confirm whether the electrical display model number is required.
Note the soft link length when ordering (normal length =250mm).
If you have any special requests, please consult us.
Product definition
Central distance between poles
Rated short-time withstand current(KA)
Rated voltage(KV)
Design No.
Indoor
Earthing switch
Introduction
The JN15-12/31.5 Series indoor earthing switch is a new design that is improved from the ES1 type. It is suitable for electric power systems with a voltage of 3\~12kV, threephase, and AC 50(60)Hz. As an earthing protection device, it can be used in various kinds of HV switchgear. It meets the GB1985-2004 and IEC 129 standards.
Mainly technical specification
Working condition
Ambient temperature:-10℃-+40℃; Altitude: ≤1000m;
Relative humidity: Daily average ≤ 95%, Monthly average ≤ 90%
Earthquake intensity:≤ 8 degree;
Dirtiness degree: II.
| No. | ltem | Unit | Data | |
| 1 | Rated voltage | kV | 12 | |
| 2 | Rated short time withstand current | KA | 31.5 | |
| 3 | Rated short circuit withstand time | S | 4 | |
| 4 | Rated short circuit making current | KA | 80 | |
| 5 | Rated peak withstand current | KA | 80 | |
| 6 | Rated insulation level | 1min power frequency withstand voltage | kV | 42 |
| Lightning Impulse withstand voltage | 75 | |||
| 7 | Mechanical life | TIMES | 2000 | |
EK6-12/31.5 earthing switch(ES-10/31.5) Outline and installation dimension
| Specification | E | F | G | H | D | C |
| JN15-12/31.5-165 | 165 | 75 | 160 | 565 | 426 | |
| JN15-12/31.5-180 | 180 | 75 | 160 | 595 | 456 | |
| JN15-12/31.5-200 | 200 | 75 | 160 | 635 | 496 | |
| JN15-12/31.5-210 | 210 | 75 | 160 | 655 | 516 | |
| JN15-12/31.5-220 | 220 | 75 | 160 | 675 | 536 | |
| JN15-12/31.5 230 | 230 | 75 | 160 | 695 | 556 | 96 |
| JN15-12/31.5-250 | 250 | 75 | 160 | 735 | 596 | 96 |
| JN15-12/31.5-275 | 275 | 75 | 185 | 810 | 646 | 96 |
Please confirm whether the electrical display model number is required.
Note the soft link length when ordering (normal length =250mm).
If you have any special requests, please consult us.
Product definition
Central distance between poles
Rated short-time withstand current(KA)
Rated voltage(KV)
Design No.
Indoor
Earthing switch
Introduction
JN17-12/40 (Old type is JN15-12/40) Series indoor high voltage earthingswitch is a new design and improved product based on the ES1 type.The structure is assembled and suitable for electric power system with3\~10KV, three-phase and AC 50(60)Hz. As an earthirng protection, itcan be used in various kinds of HV switchgears. It meets GB1985- 2004and IEC129 standard.
Mainly technical specification
Working condition
Ambient temperature:-10℃-+40℃; Altitude: ≤1000m;
Relative humidity: Daily average ≤ 95%, Monthly average ≤ 90%
Earthquake intensity:≤ 8 degree;
Dirtiness degree: II.
| No. | Item | Unit | Data | |
| 1 | Rated voltage | kV | 12 | |
| 2 | Rated short time withstand current | KA | 31.5 | |
| 3 | Rated short circuit withstand time | S | 4 | |
| 4 | Rated short circuit making current | KA | 80 | |
| 5 | Rated peak withstand current | KA | 80 | |
| 6 | Rated insulation level | 1min power frequency withstand voltageLightning Impulse withstand voltage | kV | 42 |
| 75 | ||||
| 7 | Mechanical life | TIMES | 2000 | |
EK6-12/31.5 earthing switch(ES-10/31.5) Outline and installation dimension
| Specification | E | F | G | H | D |
| JN17-12/40-210 | 210 | 50 | 185 | 655 | 516 |
| JN17-12/40-220 | 220 | 50 | 185 | 675 | 536 |
| JN17-12/40- 230 | 230 | 50 | 185 | 695 | 556 |
| JN17-12/40-250 | 250 | 50 | 185 | 735 | 596 |
| JN17-12/40-275 | 275 | 50 | 210 | 810 | 646 |
Please confirm whether the electrical display model number is required.
Note the soft link length when ordering (normal length =250mm).
If you have any special requests, please consult us.
Product definition
Central distance between poles
Rated voltage(KV)
Design No.
Indoor
Earthing switch
Introduction
JN17-12/50 series (previously JN15-12/750) earthing switch is a newly designed and improved product based on the ES1 model. The structure is modular and suitable for power systems with 3-10kV, three-phase AC at 50/60Hz. It serves as an earthing protection device and can be used in various types of high-voltage switchgear. The product complies with GB985-2004 and IEC129 standards.
Working condition
Ambient temperature:-10℃-+40℃; Altitude: ≤1000m;
Relative humidity: Daily average ≤ 95%, Monthly average ≤ 90%
Earthquake intensity:≤ 8 degree;
Dirtiness degree: II.
| No. | ltem | Unit | Data | |
| 1 | Rated voltage | kV | 12 | |
| 2 | Rated short time withstand current | KA | 50 | |
| 3 | Rated short circuit withstand time | S | 4 | |
| 4 | Rated short circuit making current | KA | 100 | |
| 5 | Rated peak withstand current | KA | 80 | |
| 6 | Rated insulation level | 1min power frequency withstand voltage | kV | 42 |
| Lightning Impulse withstand voltage | 75 | |||
| 7 | Mechanical life | TIMES | 2000 | |
EK6-12/31.5 earthing switch(ES-10/31.5) Outline and installation dimension
| Specification | E | F | G | H | D |
| JN17-12/50-210 | 210 | 50 | 185 | 655 | 516 |
| JN17-12/50-220 | 220 | 50 | 185 | 675 | 536 |
| JN17-12/50- 230 | 230 | 50 | 185 | 695 | 556 |
| JN17-12/50-250 | 250 | 50 | 185 | 735 | 596 |
| JN17-12/50-275 | 275 | 50 | 210 | 810 | 646 |
Please confirm whether the electrical display model number is required.
Note the soft link length when ordering (normal length =250mm)
If you have any special requests, please consult us.
Introduction
JN15-24/31.5 series indoor earthing switch is a newly designed and improvedproduct based on the JN15 model (with unchanged installation dimensions). It is suitable for powersystems with 20-24kV, three-phase AC at 50/60Hz. As an earthing protection device, it can be applied in various types of high-voltage switchgear. The product complies with GB1985-2004 and IEC129 standards.
Mainly technical specification
Working condition
Ambient temperature:-10℃-+40℃; Altitude: ≤1000m;
Relative humidity: Daily average ≤ 95%, Monthly average ≤ 90%
Earthquake intensity:≤ 8 degree;
Dirtiness degre: II.
| No. | Item | Unit | Data |
| 1 | Rated voltage | kV | 24 |
| 2 | Rated short time withstand current | KA | 31.5 |
| 3 | Rated short circuit withstand time | S | 4 |
| 4 | Rated short circuit making current | KA | 80 |
| 5 | Rated peak withstand current | KA | 80 |
| No. | Item | Unit | Data | |
| 6 | Rated insulation level | 1 min power frequency withstand voltage | KV | 65 |
| 7 | Lightning Impulse withstand voltage | 95 | ||
| 8 | Mechanical life | TIMES | 2000 | |
| Specification | E | F | G | H | D | D |
| JN15-24/31.5-210 | 210 | 50 | 160 | 655 | 516 | |
| JN15-24/31.5-220 | 220 | 50 | 160 | 735 | 536 | |
| JN15-24/31.5- 230 | 230 | 50 | 160 | 810 | 556 | 96 |
| JN15-24/31.5-250 | 250 | 50 | 160 | 810 | 596 | 96 |
| JN15-24/31.5-275 | 275 | 50 | 185 | 810 | 646 | 96 |
Product definition
Central distance between poles(mm)
4S thermal stability current(KA)
maximum voltage(KV)
Design No.
Indoor earthing switch
Introduction
The JN22B-40.5/31.5 series indoor HV earthing switch is researched and developed by Xi'an HV Electric Research Organization. It features advanced design, stable performance, simple structure, and easy mounting and adjustment. This switch is suitable for electric power systems with a voltage of 40.5kV, three-phase, and AC 50Hz. As an earthing protection device, it can be used in KYN-40.5 or other types of switchgear. It complies with GB 1985-2004 and IEC 129 standards.
Working condition
Ambient temperature:-10℃-+40℃; Altitude: ≤1000m;
Relative humidity: Daily average ≤ 95%, Monthly average ≤ 90%
Earthquake intensity:≤ 8 degree;
Dirtiness degree: II.
| No. | Item | Unit | Data | |
| 1 | Rated voltage | kV | 12 | |
| 2 | Maximum voltage | KA | 50 | |
| 3 | Rated short time withstand current | S | 4 | |
| 4 | Rated short circuit withstand time | KA | 100 | |
| 5 | Rated short circuit making current | KA | 80 | |
| 6 | Rated peak withstand current | 42 | ||
| 7 | Rated insulation level | 1min power frequency withstand voltage | KV | 75 |
| Lightning Impulse withstand voltage | 2000 | |||
| 8 | Central distance between poles | TIMES | ||
Outline and installation dimension
Please confirm whether the electrical display model number is required.
Note the soft link length when ordering (normal length =250mm).
If you have any special requests, please consult us.
General
The controller of the DN15-3.5 earthing switch provides control and protection for the motor operating mechanism. If the electric mechanism encounters difficulty driving the motor—such as improper installation or a jam in the mechanism—the controller will detect the fault condition, immediately stop the motor, and reverse its operation to release the jammed chassis.
Introduction
To meet the evolving demands of power switchgear, we developed the electric earthing switch, which has been awarded a national invention patent. Maintaining the original style and interlock functions of the switchgear, the electric earthing switch incorporates a motor operating mechanism based on the original JN15, N17, N228, and JN22 series earthing switches. It retains the characteristics of the original earthing switch while enabling electric operation. Additionally, electric and manual operations do not require switching, satisfying the requirements for automated operation in power systems
Control logic
Electric open and close operations are permitted when the interlock signal is satisfied.
During the switch opening and closing operation, if a switch opening or closing instruction is issued, the controller will execute the original operation.
If the open/close buttons on the panel are pressed simultaneously or if the interlock signal becomes invalid during the operation, the controller will halt the operation.
When the blocking rotation protection condition is met, the blocking rotation protection current setting is configured to 1A.
The time limit for electric opening and closing operations is set to 12 seconds. If the time expires and the relay is not in the correct position, the system will stop and trigger an alarm.
Wiring diagram
Technical Parameters
Supply voltage: AC/DC 220V,AC/DC 110V
Motor rated voltage: DC220V, DC110V
Rated power of motor: Max 300w
Power consumption:< 2W
Power frequency withstand voltage: AC2.5KV 1min
Output contact:1NO.3A,AC 250V
Protection: IP20
Working temperature:-20C to +50°℃
Dimensions: L\*W\*H=125\*78\*69
Installation: door panel installation
Installation hole size
Statement:
The four φ5 openings in above picture are the fix installation openings of controller on the panel. Φ20-40 opening is used to go through the connection cable inside the controller.
The opening is used for thecable of the controller. Ans it has no strict requirementof processing dimension tolerances.
Outline and installation dimension
1、DPC-4A-450 Chassis truck outline and installation dimension (match VD4)
DPC Chassis truck definition
Wide:650mm,800mm,1000mm
A: wheel with bearing, noA: wheel without bearing
Design No.3、4、5
DPC-□-□Chassis truck order notes
Please specify the chassis truck specifications, lock plate code, and the specifications of the auxiliary switch (e.g., 5 NO, 3 NO & 2 NC, etc.).
Indicate the earthing method.
For any special requests, please consult us.
Note: The specifications of the auxiliary switch do not reflect its state when the chassis truck is in the testing position.
Chassis truck
Introduction
Chassis truck is primarily designed to support circuit breakers, transformers, and other components in withdrawable switchgear. It facilitates the pushing and extraction of the chassis. As an auxiliary operation, it connects components and busbars. When operated with the internal mechanism of the circuit breaker and the interlock mechanism of the mid-placed cabinet, it meets the interlock requirements of the "5 Preventions" stipulated in GB3906. The specific functions are as follows:
Circuit breaker can only be closed when the handcart is in the testing, isolating, or working position. When the handcart is in the locked state, this prevents misconnection and mismatched isolation contacts with the load.
If the handcart is in the working position or moves 110 mm away from the testing/isolating position, the earthing switch fails to close, thus avoiding unintentional operation of the switch.
When the earthing switch is closed, the handcart cannot shift from the testing/isolating position to the working position, preventing the circuit breaker from closing inadvertently.
Once the chassis enters the cabinet and moves away from the testing/isolating position, the handcart cannot be drawn out of the cabinet.
Lock plate of the chassis truck
Note: There are five types of lock plates available for selection. The standard specification is 8EB.141.012. If you require any of the other four lock plates, please specify your choice when placing the order.
| Product Type | A | B | C | D | E | F |
| DPC-4-650 | 500 | 450 | 410 | 38513×30 | 502 | 535 |
| DPC-4A-650 | ||||||
| DPC-4-800 | 650 | 600 | 560 | 520 | 652 | 685 |
| DPC-4A-800 |
| Product Type | A | B | C | D | E | F | G |
| DPC-5-800 | 650 | 600 | 520 | 520 | 652 | 685 | 25 |
| DPC-5A-800 | |||||||
| DPC-5-1000DPC-5A-1000 | 850 | 800 | 720 | 700 | 852 | 885 | 45 |
8、Earthing method of chassis truck
(1) Installation of earthing bar(650/800)
(2)Earthing bar installation (type 1000)
| Type | A |
| DPC-□-650 | 100 |
| DPC-□-800 | 160 |
(3) Installation size of earthing contact
(4) Guide rail earthing(both side)
| Type | A |
| DPC-□-650 | 180 |
| DPC-□-800 | 296 |
| DPC-□-1000 | 496 |