Worldwide Air Conditioner Partner
TMV6
Full-DC inverter Central air conditioning system
High Efficiency and Energy Saving
Full DC Design
Surrounding Refrigerant Cooling Technology
Electric Control Box Refrigerant Cooling
Using liquid refrigerant cooling control box system is less affected byenvironmental, when ambient temperature is up to 56°C, the systemcan still keep stable and reliable.
Wide Operation Temperature Range
Wide operation range, cooling: -15°C\~56°C heating: - 3 0 ^ { \circ } C - 2 8 ^ { \circ } C
Easy installation
1100m Super Long Piping Design
. The industry-leading piping length, with a total length of 110Om, makes floor design more flexible.
. The max distance between the IDU and the ODU (the higher ODU) is 100m. The max distance between the IDU and the ODU (the lower ODU) is 11Om.
. The maximum distance between indoor units is 40m.
. The maximum actual single pipe length is 220m.
. The maximum equivalent single tube length is 240m.
. The equivalent length from first indoor distributor to last indoor unit 120m.
130Pa External Static Pressure
Through the combined action of new fan blades and high-volume fans, the system achieves higher external static pressures of up to 130 Pa\* to ensure heat dissipation in layered or centralized placement of outdoor units
Better heat dissipation, better refrigeration effect
Easy Maintenance
Anti-adversity Function
The external force blows the outdoor unit fan to rotate in reverse. At this time, start and stop the rotation of the fan, and then restart the fan motor in a forward rotation according to the normal procedure, so as not to damage the fan motors due to excessive starting current.
Against the wind
Electronic Control Board SMT Placement Technology
The external force blows the outdoor unit fan to rotate in reverse. At this time,start and stop the rotation of the fan, and then restart the fan motor in a forward rotation according to the normal procedure, so as not to damage the fan motors due to excessive starting current.
Outstanding Reliability
Triple Backup System Technology
Compressor backup operation Emergency operation of fan motor ODU backup operation
Multiple Protection Functions
Low voltage recognition function Lightning protection Compressor overload protection Motor overheating protection
Compressor overload protection
Phase sequence protection
Anti-freeze protection
Current protection
High voltage protection
Intelligent Control Solution
System Cloud Control and Management
IDU Lineup
| Series | Fanmotor | Model | Capacity range(x10Ow) | ||||||||||||||||||||||||
| 18 | 22 | 25 | 28 | 32 | 36 | 40 | 45 | 50 | 56 | 63 | 71 | 80 | 90 | 100 | 112 | 125 | 140 | 160 | 180 | 220 | 224 | 280 | 450 | 560 | |||
360°Q8cassette | DC | TMV-V(**) Q8/N1D1 (E) | O | ● | |||||||||||||||||||||||
compactcassette | DC | TMV-V(**) Q4R/N1D1Y (E) | C | ||||||||||||||||||||||||
Low ESPSlim Duct | DC | TMV-V(**) F5/N1DY(E) | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ● | ||||||||||||
Free ESP Duct | DC | TMV-V( ** ) F2/N1DY(E) | ● | ● | O | 金 | C | C | C | C | |||||||||||||||||
| Wall- mounted(External EXV) | DC | TMV-V(**) G/N1DY-B(E) | ● | ● | ● | C | ● | O | ● | C | ● | ● | |||||||||||||||
| Wall- mounted(Built-in EXV) | AC | TMV-V(**) G/N1Y-B(E) | ● | C | |||||||||||||||||||||||
High staticpressure duct | AC | TMV-V(**) F1/N1Y(E) | ● | ● | C | ||||||||||||||||||||||
Fresh air duct | AC | TMV-V(**) F1/XFN1Y(E) | C | ● | C | ||||||||||||||||||||||
Ceiling & Floor | AC | TMV-V(**) ZD/N1Y(E) | C | O | O | ||||||||||||||||||||||
One-waycassette | DC | TMV-V(**) Q1/N1DY(E) | ● | ● | ● | C | ● | ● | ● | ||||||||||||||||||
Two-waycassette | AC | TMV-V(**)Q2/N1Y(E) | ● | O | ● | C | ● | ● | 家 | ||||||||||||||||||





360°Q8cassette
compactcassette
Low ESPSlim Duct
Free ESP Duct
High staticpressure duct
Fresh air duct
Ceiling & Floor
One-waycassette
Two-waycassette