TABLE OF CONTENTS
The copyright of this manual belongs to our company.
1.SafetyPrecautions..................................................................................01
2.Air Conditioner Structure and Composition ........................................04
3.Operation Guide and Troubleshooting................................................ 05
4.Installation Instructions ........................................................................08
5.Technical Parameters and Environmental Protection Instructions ....10
6.User Service Guide ................................................................................11
7.Operating Conditions and Packing List ................................................12
8.Cleaning and Maintenance ...................................................................13
·This manual is a general version. The appearance of the product is
subject to the actual item.
·In case of product technology or software upgrades, no further notice
will be given.
·This product is for use only after the vehicle has stopped or the engine
has been turned off.
·This product employs 72V electronic control and inverter technology
for continuous speed adjustment. The panel remote control does not
interfere with the operation of any functions.
SAFETY PRE“Prohibited” sign. Any content bearing this symbol
represents actions that must be strictly prohibited, as failure
to do so could result in damage to machinery or endanger
the safety of the user.
Non-professionals are strictly prohibited from installing this
product: Any modification or unauthorized installation of this
product is strictly forbidden. Otherwise, it may lead to
consequences such as water leakage, malfunction, electrical short
circuit, electric shock, explosion, and fire.
Please do not touch the switch with wet hands, otherwise it may
cause an electric shock accident.
It is prohibited to move the piping privately.
It is strictly prohibited to install this product near hot objects to
avoid aging and deformation of the product's casing and other
components, which may affect its normal operation.
When installing this product, it is strictly prohibited to place it
close to gas supply devices for flammable gases and other liquid
or solid devices and appliances that are volatile, flammable, or
explosive. In case of a leakage of flammable substances, it may
lead to accidental fires or accidents.
The air conditioner compressor must not operate with
compressed air. When air is mixed into the air conditioning
system, it is strictly prohibited to run for a long time. Otherwise, it
may cause faults, explosions or fires and other accidents.
ECAUTIONS
Ensure the power supply is disconnected before completing all
installation, wiring and inspection work.
After the installation of this product, check whether the drain port is
blocked. If the drainage is not smooth, leading to the overflow of
condensed water from the air conditioner, it may cause loss of the
user's personal belongings. (Split unit)
If pipeline welding and other work are required during installation,
keep away from containers of various flammable and explosive
substances (including air conditioner refrigerants) to ensure the
safety of the construction site.
During installation, ensure the installation and fixing position can
bear the weight of the machine, and provide auxiliary support if
necessary.
During wiring, ensure the crimping is firm and reliable; otherwise,
loose crimping may easily cause sparking and overheating at the
contact points, and even cause fires.
Only qualified electricians can perform the wiring work of this
product, and all wiring shall be carried out in accordance with
relevant electrical regulations. If the power cord is damaged, to avoid
danger, you must contact our company's service hotline for handling.
Before installation and wiring, please carefully refer to the relevant
diagrams in the product manual. Incorrect installation and wiring
connections will not only damage the product, but also may lead to
accidents such as personal injury.
Please do not stay in the cold air from the air conditioner for a long
time, or set the temperature too low. Otherwise, it may affect your
health.
\"Warning\" sign: All contents marked with this sign are
related to product safety and the user's personal safety, and
operations must be carried out in strict accordance with the
warning contents.
SAFETY PREPrecautions during relocBefore conducting inspection and maintenance, the power supply
of the air conditioner must be disconnected first. Otherwise, it
may cause accidents such as malfunctions, electric shock,
explosion or fire.
After the air conditioner has completed the maintenance and
inspection work, it is strictly prohibited to leave any foreign
objects such as metal fragments or wire ends inside the machine
being repaired. Otherwise, it may cause faults, electric shock,
explosion or fire and other accidents.
During maintenance, it is strictly prohibited for fingers, gloves,
clothes, etc. to come into contact with the rotating parts of the fan
to avoid causing personal injury.
It is prohibited to connect the power cord in the middle or to use
an extended wire. It is also prohibited to damage the power cord.
The positive and negative poles must not be connected reversely;
otherwise, it may cause electric shock, damage to the computer
board, fire and other accidents.
ECAUTIONS
cation and maintenance
Before conducting inspection and maintenance, the power supply of
the air conditioner must be disconnected first. Otherwise, it may
cause accidents such as malfunctions, electric shock, explosion or
fire.
After the air conditioner has completed the maintenance and
inspection work, it is strictly prohibited to leave any foreign objects
such as metal fragments or wire ends inside the machine being
repaired. Otherwise, it may cause faults, electric shock, explosion or
fire and other accidents.
During maintenance, it is strictly prohibited for fingers, gloves,
clothes, etc. to come into contact with the rotating parts of the fan to
avoid causing personal injury.
Operation Guide aPanel Interfac
and Fault Inquiry
ce Description
24V positive electrode
feedback signal Speed control signal fan- fan+
temperature control line
negative electrode
Operation Guide and Fault Inquiry
Core temperature sensor Internal and external machindrive
panel
Inlet air temperature sensor
Evaporator fan
Evaporator fan connection line
Condenser fan connection wire
ne connection cables
condenser fan
electric compressor
Operation guide aRemote Contrsleep mode
Wind speed adjustment
Power Saving Mode
and fault inquiry
rol Instructions
on/off
Powerful Mode
swaying wind
timing
temperature regulation
fault code cause EL Under-voltage protection
EH Overvoltage protection
EC Temperature sensor failure
EF Internal fan failure
short circuit or overcurrent in the fan
E2 Compressor overcurrent protection
E3 Compressor phase loss or overload
protection
E4 Compressor controller under-voltage
protection
E5 Compressor short-circuit protection
E6 Controller overvoltage protection
Checkcheckis too ChecktempeCheckToo mheat sThe ccloggeCheckthe neCheckthe coCheckE7 Three consecutive failures in startup attempts This isoff theE8 Outdoor fan failure
H2 Controller phase loss protection
CheckE9 The temperature switch or pressure switch
has been disconnected CheckCheckH3 Controller power device over-temperature
protection
H4 Controller reference sampling error
ReducThen, The elthe ele
solution
k whether the power supply lines are too long, too thin or have poor contact;
k the system voltage and under-voltage settings; the generator's output voltage
high.
k the connectors of the environmental temperature probe and the core body
erature probe, or replace the temperature probes.
k whether the indoor fan has a short circuit or carbon brush problem.
much refrigerant has been added; the condenser needs cleaning, and there is a
source at the installation location.
connection line of the compressor is not properly connected, the pipeline is
ed, or the compressor is stuck.
k the main power line to see if the connecting wires are too long or too thin, or if
egative pole is connected to the frame.
k for any wear or short circuits in the connection line between the controller and
ompressor.
k if the system voltage exceeds 32V. The voltage of the generator is too high.
s usually caused by E3 or E12. Check the compressor connection wires, then turn
e machine for 10 minutes before restarting it.
k the connection lines of the fan.
k the system pressure or temperature switch.
k the connection lines of the compressor.
ce the amount of refrigerant filled and enhance the system's heat dissipation.
shut down the machine for 30 minutes before restarting it.
lectronic fan short-circuited, causing internal damage. Replace the controller and
ectronic fan at the same time.
INSTALLATION INSTRUCTIONS
■The installation position of the main unit must avoid the heat sources of the
engine and the muffler. Ensure good ventilation and dust prevention. Avoid
resonance.
■When pressing the pipe head, pay attention to the force applied to prevent
deformation of the inner diameter hole of the pipe core.
■The length of the air conditioning pipe and the positive and negative main wires
should be as short as possible. The refrigerant is R134a and has been filled.
■The red wire should be connected to the positive terminal of the battery (the
end with the fuse), and the black wire should be connected to the negative
terminal of the battery. Tighten to ensure good electrical contact. Do not connect
the black wire to the ground wire. Be careful not to make a mistake.
■During installation, monitor the pressure to ensure there are no leaks before
evacuating for more than 20 minutes and opening the outdoor unit valve.
■It is recommended to install the indoor unit on the right side of the passenger
seat at the top.
■If the installation or use does not follow the above relevant requirements,
resulting in air conditioning failures or other losses, our company will not bear any
direct or indirect responsibility.
Installation precautions
■The installation location should ensure unobstructed air inlet and outlet;
■Choose a place that is easy to drain condensate water and is convenient for
connection with the outdoor unit;
■The installation position of the air conditioner should be determined according
to the actual situation of the vehicle and the relevant \"wiring requirements and
pipeline layout\";
■According to the selected installation position of the indoor part of the air
conditioner, at least 6 fixing points for the indoor unit must be ensured;
■If drilling is required in the driver's
cabin, it is necessary to consult the
vehicle manufacturer before drilling to
confirm that the drilling location does not
affect the circuits, lines, oil lines,
structural strength, and other usage
functions;
■A 15mm return air space needs to be
reserved above the figure on the right;
Selection of installation location
Top of the vehicle
Above 5cm Above 5cm
Step 1:Installation of indoor unit. Locate a suitable position to install the
indoor unit. First, fix the wooden board of the indoor unit to the appropriate
position in the cab using four screws. Then, secure the indoor unit onto the
wooden board (screws are provided in the packaging box).
Installation steps
Step 3: First, make holes. Connect the pipeline to the wiring harness. The plug
connection is simple and quick. During installation, apply refrigerating oil; do
not use engine oil as it may cause the rubber ring to oxidize and leak
refrigerant.
Step 4:Test and evacuate the R134a filling valve, and check for any leaks.
Step5:You need to remove the vacuum pump after some time. Use an internal
hexagonal wrench to open the copper valve of the outdoor unit. Note! Open
the high-pressure valve first, then the low-pressure valve (the high and low
pressure pipes are marked). Make sure to fully open both copper valves to
ensure that the refrigerant can flow freely in the piping.
Step 6:Wrap the indoor pipes, wiring harnesses, and condensate water pipes
with white adhesive tape. Ensure that the pipes, wiring, and condensate
water pipes are securely fixed without any friction, collision, or shaking.
Step 7:Connect the positive and negative cable wires. The red wire should be
connected to the positive terminal of the battery, and the black wire to the
negative terminal.(Note: The battery wires must be securely fixed.)
Step 8: Turn on the power switch. Set the remote control to the \"cooling\"
mode. Press the temperature adjustment button on the remote control and
set the temperature to the lowest level. Then, start the test run.
Step 2 : Installation of the outdoor unit. Based on the
length of the wiring and piping, select the optimal
position to install the outdoor unit. First, fix the bracket
at an appropriate position on the driver's cabin, then
use rivets to secure the bracket, and finally place the
outdoor unit flat and fix it with screws. When installing
the bracket, apply foam glue and add foot pads to
prevent resonance.
INSTALLATION INSTRUCTIONS
Installation precautions
Step 1:Installation of indoor unit.
Locate a suitable position to install
the indoor unit. First, fix the wooden
board of the indoor unit to the
appropriate position in the cab
using four screws. Then, secure the
indoor unit onto the wooden board
(screws are provided in the
packaging box).
Start the vacuum pump to perform
vacuuming. Run it for more than 15
minutes and observe until the
vacuum gauge reaches -0.1 Mpa (-760
mmHg).
Fully close the low-pressure valve and
stop the operation of the vacuum
pump. Please maintain this state for
1-2 minutes or more, then confirm
whether the pointers of the high and
low pressure gauges have returned. If
they have returned, check the leakage
points and repair them. After that,
please perform the vacuuming
operation of the vacuum pump again.
Rotate the two-way and three-way
stop valves counterclockwise in the
opposite direction until they are fully
open.
Tighten the caps on the two-way and
three-way stop valves as well as the
screws on the filling ports.
leakage detecting
High pressure gauge
vacuum pressure gauge
Low pressure valve
refrigerant pipe
high-pressure valve
refrigerant pipe
vacuum pump
valve body
valve stem
nut
nut
Dip a sponge block in soapy water or use a leak detector to inspect all the
openings of the indoor and outdoor units.
Inspect the shut-off valves and stay at each location for at least 3 minutes.
Pre-test inspection
■ Connect the power cord to the vehicle battery terminal. It is recommended to
add a power control switch for easier disconnection and connection. Pay
attention to not reversing the positive and negative poles. Check if the wiring is
properly connected, tightened, and especially ensure that the connecting wires
are fully pressed.
■ Check if the internal and external units are installed firmly. Pay attention to
sealing the pipe holes with sealant or other methods to prevent water leakage and
air leakage, and try to coordinate with the vehicle sound.
■ After remote control startup, set the cooling operation according to the current
room temperature. Set the setting to the lowest level steadily.
■ The test run should last for more than 30 minutes for comprehensive
inspection. (It should be no less than 15 minutes.)
■ In case of special circumstances, the indoor and outdoor connection pipes
need to be extended. Please add the refrigerant as per the table below.
Voltage Query and Battery Protection
Voltage Query: When the device is powered on, simply press the \"Voltage\" button
to view the current battery voltage.
Note:Due to the varying battery characteristics of vehicle storage batteries, the
voltage values obtained during operation may differ. This information is provided
for reference only.
Increase the length of the connecting pipe to increase the refrigerant dosage (R134a)
No need to add
(connecting pipe length-5)×30g
≤5m
5-10m
Technical Specifications and EnAll product models and technical parameters
Environmental Protection Description
The names and contents of hazardous substances in the product
Component Name
Pb Hg Cd Cr(VI) PBB PBDE
Compressor and accessories
Refrigerant
Motor
Heat exchanger
Pipe fittings
Valves
Nuts and other fasteners
Other metal parts
Controllers and electrical components
deadening
froth
Other plastic parts
rubber articles
Power cord and connecting wire
Packaging printing components
hazardous substance
Parameter Name explain
Input Voltage (V) DC-24V
customized cooling capacity 500-2400W
power rating 800W
rated current 10A-30A/35℃
*The components in
the details are a
summary of the
main components
included in different
models. Whether
this product
includes this
component
depends on the
actual configuration
of the product.
*Other components
of this product and
their homogeneous
materials not listed
in the details do not
contain harmful
substances.
*All components
and homogeneous
materials containing
harmful substances
in the details comply
with the strict
requirements of EU
ROHS for the
restriction of the use
of harmful
substances. Please
feel free to use
them.
nvironmental Protection Notes
This table is compiled in accordance with the provisions of SJ/T11364.“O”
It indicates that the content of the harmful substance in all homogeneous
materials of this component is below the limit requirements stipulated in GB/T
26572.
\"X\" indicates that the content of the harmful substance in at least one
homogeneous material of this component exceeds the limit requirements
specified in GB/T 26572. Currently, there is no mature alternative solution in the
industry. Subsequent technological progress will gradually reduce the use of the
harmful substance.
Cautionary reminder:
To protect the environment, after the of this product or its components, as a
consumer, you have the responsibility to separate it from household garbage and
send it to a qualified recycling site. The recycling and treatment site will classify,
dismantle, and recycle it according to relevant national regulations.
For details on the recycling and treatment of this product, please consult the local
government, waste disposal institutions, etc.
User ServMatters need attention
Please check if the \"Appendix\" in this guide is complete so that you can receive the
services provided by our company. If you find that the card is missing, you can
immediately request the unit selling the air conditioner to replace this guide.
Although each air conditioner undergoes strict testing and inspection before
leaving the factory, due to long-distance transportation or improper installation, it
may affect the normal use of the air conditioner. Therefore, if you need us to
provide services such as air conditioner installation and maintenance, please call
the local customer consultation center service number.
Please check whether the installation of the power line at the air conditioner
installation location complies with relevant national regulations and electrical
safety standards, and whether it meets the power load requirements of the air
conditioner product you purchased. Also, ensure that there are good safety
protection grounding measures.
The purchase invoice is a necessary document for repairing the air conditioner
when it malfunctions during use. Please keep it properly.
When installing the air conditioner, please make sure to ask the installation
personnel to stick the serial number of the air conditioner body and the barcode
of the production date on the appendix, and fill in the purchase date and other
contents.
Maintenance Guide During Warranty Period
If your air conditioner malfunctions, please contact the local customer service
center by phone, letter or in person.
You need to provide the following information: air conditioner model, contact
person, phone number, detailed address, and the symptoms of the
malfunction.Agree on the repair time. When the repair personnel are conducting
the repair, please ask them to present their air conditioner service certificate.
Then, please show the valid purchase invoice or voucher to the repair service
personnel.After the air conditioner is repaired, it usually requires more than half
an hour of test operation. If the fault is resolved and the air conditioner operates
normally, please have the maintenance personnel carefully fill out the \"Air
Conditioner Maintenance Record Form\" attached to this guide and the air
conditioner maintenance document carried by the maintenance personnel, and
sign to confirm. If the fault is not resolved or the maintenance result does not meet
your satisfaction, please do not sign.If you have any questions or dissatisfaction
with our products and services, please report them to the local customer
consultation center or service supervision hotline. We will promptly and properly
solve the problems you raise.
(Contact information can be found on the back cover of this manual)
vice Guide
The conditions for enjoying free warranty are as follows:
A. Can provide the purchase invoice or valid purchase certificate;
B. Must be installed and repaired by the authorized air conditioner maintenance
and installation unit;
C. Must be within the warranty period;
Note: If the warranty procedures have been completed but the valid purchase
certificate or warranty card cannot be presented, the warranty period will be
calculated based on the manufacturing date indicated on the barcode.
The following situations do not qualify for free repair service:
A. Due to unstable power supply voltage outside the air conditioner's operating
voltage range, or due to improper connection of peripheral electrical lines that do
not comply with national safety electricity usage standards, resulting in damage
to the air conditioner;
B. Due to improper use by the user or poor storage, causing damage to the air
conditioner;
C. Not installed or repaired by the air conditioner's authorized installation and
maintenance unit, and thus causing malfunction and damage to the air
conditioner;
D. Without valid purchase certificate or without completing warranty procedures;
E. The purchase certificate has been altered without authorization;
F. Beyond the warranty period;
G. Due to force majeure factors causing product damage;
H. Other items not within the scope of our company's promised services;
1. Damage to the remote control caused by personal reasons is not covered by the
warranty;
J. Faults and damages caused by the harsh environment in which the air
conditioner operates (for example: blockage of the heat exchanger due to strong
sand, fracture of the compressor bolt due to poor road conditions, or other
reasons causing abnormal corrosion and damage to components);
The above service contents are provided by our company with paid services.
The charging price is executed in accordance with the unified charging standard
set by our company.
User ServTerms of Use Operating range of air conditioning
Refrigeration
and
Dehumidification
Inside the car
highest
lowest
highest
lowest
Dry bulb:32.5℃ Wet bulb:26℃
Dry bulb:21℃ Wet bulb:15.5℃
Dry bulb:50℃
Dry bulb:21℃
outside the car
When used under the above conditions, the cooling effect will slightly decrease
when approaching the maximum temperature (sun shading measures can be
adopted to prevent direct sunlight exposure).
· When the vehicle is moving or parked on a steep road and the machine is
running, it may cause cold condensate to spill out. It is advisable to avoid running
the machine on steep roads.
Note: For detailed product parameters, please refer to the electronic manual.
Before the season starts
Check if the auxiliary line pipes are in good condition; √ Remove the machine
cover;
Check if there are any obstructions blocking the inlet and outlet vents of the
indoor and outdoor units;
Check if the air filter is dirty; √ Check if the drainage pipes are unobstructed;
Check if the battery of the remote control is usable.
After using the season
Turn off the power of the air conditioner;
Clean the air filter and let it dry thoroughly before installing it into the indoor unit;
Cover the indoor and outdoor units with the covers;
Check if the drainage pipes are unobstructed;
Remove the battery from the remote control.
vice Guide
Packing List
Note:
1. Installation accessories for non-standard models can be found in the packing
list inside the accessory box.
2. Installation accessories for standard models are included in the packaging box
of the entire machine.
3. The detailed list of specific accessories can be referred to in the electronic
manual.
Complete packing list for the entire machine
serial number name type specification Units Quantity Remarks
The entire machine See the nameplate unit 1
Instruction Manual / copy 1
Remote control / piece 1
Battery Model 7 cell 2
Power cord / 1
1
2
3
4
5
Attachment: Packing List (General Model)
serial number name type specification Units Quantity Remarks
Body fixation component / set 1
Lashing strap group / group 1
1
2
Cleaning andCleaning Tips:
· For cleaning purposes, use water and a mild detergent. Avoid using gasoline,
diesel or solvents. Do not use a high-pressure cleaning machine;
· Occasionally, clean the air conditioning shell with a damp cloth;
· Regularly remove leaves or other dirt from the air conditioning grille. Do not use
sharp or hard objects; ensure that the grille is not damaged during cleaning;
· Clean the remote control with a frequently used slightly damp cloth. It is
recommended to use a glass cleaning cloth to clean the display screen.
The intended use of this product
· This device is mainly used for cooling in the cab;
· This system is an automotive parking air conditioning system and can also be
used during vehicle operation;
· This device is not applicable for agricultural and construction vehicles;
· The working temperature range of this device is 15℃ to 42℃.
Recovery processing
If you wish to carry out the final processing of this product, please
consult the local recycling center or professional dealers for detailed
instructions on how to follow the recycling regulations and operate
accordingly. Please handle this product at the official recycling
processing site that complies with the regulations.
Disposal of remote control battery waste
Do not dispose of batteries along with general household waste.
Please return defective or used batteries to the retailer or dispose of
them at a centralized collection point.
d Maintenance
Maintenance reminder!
· Try to park the vehicle in a shady area;
· Cover the vehicle body with a cover when it is not in use;
· If your vehicle does not have a vehicle air conditioning system, please open the
windows first to allow ventilation inside the vehicle, and then use this device;
· Please close the car doors and windows when using the device;
· Remove all heat sources inside the vehicle to ensure that the performance of this
device is not interfered with by other heat sources;
· Reduce the number of power-using devices inside the vehicle to possibly extend
the operating time of the device;
· Select the appropriate temperature and operation mode;
· Ensure that no cloth, paper, or other foreign objects block the outlet and return
grilles;
· If you want the appearance color of this device to match your vehicle color, only
apply paint to the top of the device shell. It is recommended to have it painted by
a professional paint shop;
· Regularly clean the vehicle body. Accumulated dust in the driver's cabin will
cause it to heat up faster;
· During the first use, there may be a slight odor. This odor is due to the
production process of the air conditioning system. It will disappear after the first
operation.
After-sales SeCleaning Tips:
From the date of purchase, if there is any quality issue, the entire machine is covered by aare not included in the free warranty and please pay attention.
· Human-induced damage;
· Damage caused by natural disasters (such as fires, earthquakes, etc.);
· Faults and damages resulting from improper operation in accordance with the precaut· Product faults and damages caused by unauthorized disassembly without the manufac
ervice and Warranty
a one-year warranty. During the warranty period, the following situations
tions stated in the user manual;
cturer's permission.
T10/T20 SPLIT-TYPE 24V Parking Air Conditioner Installation Manual