Panasonic
Graphene carbon crystal electric heater Instruction Manual
Please read this manual patiently before use
Awarrantycardisincluded
Preface
Thank you for purchasing and using our company's products.To ensure your safe and correct use of this product, please read all the contents of this manual carefully beforeuse.
Please keep this manual properly to ensure the normal use and maintenance of this product.
、 Safety Instructions
1. Install the corresponding safety socket that matches this electric heater.Make sure the ground wire is properly connected to ensure a firm plug.
2.There are dangerous voltage control components inside.Non-professional qualified personnel are not allowed to turn on the electric heater.
3. It must be kept dry.During transportation, it should not be exposed to rain or moisture.When cleaning,cut off the power supply first and do not wipe with too wet towels.
4.This heater must not be used around swimming pools,nozzles or bathtubs.
5. Do not cover the electric heater or place damp items on it to prevent overheating
6.After the usage season is over orwhen the electric heater has been out for several days without use, please unplug the power cord.
7.In case of any malfunction during use,please refer to the general troubleshooting and maintenance at the back. You can solve it by yourself. If it cannot be solved, please contact the agent. Do not open it without authorization. Otherwise, the warrantywillbewaived.
8.Do not use power supplies with voltages other than the rated voltage (220V to 50HZ).
9.A three-hole flat-head fixed socket with a reliable grounding and a specification of no less than 10A must be used.It is recommended to be equipped with a dedicated power line and have the wiring done by professionals.
Model parameters
| Product model | Overall dimensions | Rated power | Heating area |
| TJ-10 | 1050x430x90mm | 1000w | 10-13m² |
| TJ-15 | 1050x430x90mm | 1500w | 15-18m² |
| TJ-20 | 1050x430x90mm | 2000w | 20-23m² |
| TJ-25 | 1050x430x90mm | 2500w | 25-28m² |
二、 Installation and wiring
1. Secure the steel nails to the wall and hang the holes on the back cover plate ofthe electric heater onto the steel nails.
2. Secure the hanging piece to the wall with steel nails. Hang the upper groove of the electric heater horizontally on the hanging piece,and push the lower part backward into the groove to prevent the electric heater from sliding off due to vibration. 3.Portable and floor-standing electric heaters can be used either wall-mounted or floor-standing according to personal preference. 4.The power cord must be placed at the bottom of the horizontal electric heater to prevent it from being at the top.This is because the product components are vulnerable to damage from high temperatures (if the temperature on the top of the product is too high),it will shorten the service life or burn out the electric heater.Therefore,do not use it upside down. The heater must not be placed directly under the power socket.
三、Maintenance methods
1.Do not plug the electric heater into the power socket before it is cleaned or assembled.
2. Keep the electric heater away from dust, lint and other substances.When cleaning witha vacuum cleaner, unplug the power cord.Never disassemble the electric heater for cleaning.When cleaning the shell, please wipe it dry with a cloth dampened with detergent. Do not use anyabrasive tools or solvents that may damage the surface to clean it.
3.Do notallow water or other liquids to enter the electric heater.
四、 Operating Instructions
Technical Parameters
1.Power Supply: \mathsf { A C } 2 2 0 \mathsf { V } ± 3 0 \mathsf { V } 5 0 / 6 0 H z
2.Temperature Sensing: NTC thermistor
3.Self Power Consumption: \mathbf { \bar { \rho } } _ { < } 1W
4.Control Accuracy: ± 1 9 0
5.Temperature Setting Range: 5 ~ 6 5 ^ { \circ } { \mathsf { C } }
6.Temperature Display Range: 0 ^ { \circ } \mathsf { C } { ~ } 8 5 ^ { \circ } \mathsf { C }
7. Operating Ambient Temperature: 0 { ~ } 6 0 ^ { \circ } \mathsfit { C }
8. Humidity: 5 ~ 9 5 % \mathsf { R H } (non-condensing)
9.Housing Material: High-grade \mathsf { P C } + ABS
flame retardant plastic
10.Buttons:Touch buttons
11.AllowableLoadCurrent:30A
Functions and Operation Instructions:
1.Power On:Press thepower buton,and the display will show the ambient temperature.
2.Temperature Setting: Presstheupand down buttons to set the temperature ( 5 \small { ~ } 6 5 ^ { \circ } ~ \mathsf { C } ) ).Heating activateswhen the ambienttemperature is lower than the settemperatureand the temperature diference exceeds the hysteresis value; heating stops when the ambient temperature is equal to or higher than the set temperature.
3.Humidification Function:Press the Mode button to turnon humidification,and the humidification indicator light williluminate.Press the Mode butonagain toexit humidification mode.Once humidification is enabled, it will automatically shut down after running for 4 hours.
4.Timed Power On/Off:When the device is powered on,press the "Set" button to display the timed shutdown time,then press theupand down butons to set the shutdown time.When the device is powered off,press the "Set"buton to display the timed startup time,then press theupand down buttons to set the startup time.The system will enter countdown mode after the setting is completed.The timing setting range is O-24 hours;a value of O disables the timing function.
5.Child Lock: Press and hold the Set buton for 5 seconds toactivate the child lock and lock allbuttons.
Press and hold the Setbutton foranother 5 seconds to deactivate the child lock.
6.Hysteresis Value Seting:In power-offstate,press and hold the corresponding buttonfor5seconds until P1 is shown on the screen.Press the \square \sqcup \square \square and down buttons to adjust the hysteresis value (range: 1 { ~ } 5 % ,factory default: 2 ^ { \circ } \mathsf { C } ).Press the corresponding buttonagain to exit after finishing setting.
7.Temperature Compensation Seting:In power-off state,press and hold the corresponding button for 5 seconds to show P1,press the seting button to switch to P2.Then press theupand down buttons to adjust the temperature compensation value (range: - 5 - 5 9 ,factorydefault: 0 ^ { \circ } \mathsf { C } ).Pressthe corresponding buttonagain to exitafter setting is done.
8.When no button operation is performed for 60 seconds under power-on status,the screen will turn off automatically.Inscreen-off state,only the powerbutton indicatorlight,child lock icon (ifactivated), heating icon and humidification icon remain displayed.
Remote Controller:
1.Press the "ON" key to power on the unit,and press the "OFF" key to power it off.
2.Press "Tem+" and "Tem-" keys to set the heating temperature.
3.Press "Time+" and "Time-" keys to set the countdown shutdown time; setting it to OH means the
countdown function is disabled.
4.Press the "LOCK" key to enable or disable the child lock function.
5.Press the "Mode" key to turn humidification on or off.
Operating instructions for mechanical models
This temperature controlisaliquid expansion type,which issturdyand durable withan extremely lowfailurerate.When the temperature control is in operation, the machine's own temperature ranges from 3 0 ^ { \circ } \mathsf { C } to110℃C,significantlyextendingthe machine'sservice life.
五、Precautions
1.The heater must not be placed directly under the power socket.
2. Once the power cord is damaged,it must be replaced by an after-sales service center or a professional.
3.Usersare not alowed to disassemble or replace the internal parts of the electric heaterat will. In case of any malfunction,they must contact the after-sales service department for repair.(There are no parts in this electric heater that users can repair.)
4.Any changes to the functional structure will not be notified separately.The product shall prevail.
5.Warning: To prevent overheating,do not cover the heater.
6. Do not use this heater around bathtubs, showerheads or swimming pools.
六、 Faults and troubleshooting methods
| Fault | Cause of occurrence | Exclusionmethod |
| The electric heater doesn't get hotafter being connected to electricity | 1.The power socket is not properly connected 2.The power connector inside the electric heater isnotproperlyconnected 3.Check whether the knob of the temperature controllera issetto the minimum value 4.Check if the indoor temperature is | 1. Check whether the power socket is connected properly 2.Return to the factory for replacement |
| Semet aetric ingcondoned to electricity | toohigh The connection of the heating wire is burned out or fallsoff | Return to the factory for replacement |
| Whenused for too long,static electricity is generated on the surfaceof the electric heater | Check whether the power ground wire has come loose or is missing | Check and connect the ground wireroperlyfthereistileakage retumittothefactoryforreplacement |
| When E1and E2 flashes occur | Theecrtris | Replace |
七、Warranty card
| Installation unit | Contact number | |||||
| Product model | Factory serial number | |||||
| Purchase date | Year Month Date | Installation date | YearMonth Date | |||
| Have youchecked he powersupply? | □Are口No | Wetherthe orctusagshas he mastred | □Are口No | |||
| Have you checked the thermostat | □Are口No | Whetherthesafeystructiosfoeeepd | □Are□No | |||
| Customer telephone number | ||||||
| Installation technician Sign | Year Month Date | Customer signature | YearMonth Date | |||
八、Maintenance record
| Repair date | Maintenance content | Maintenance worker's signature | Remarks |
Warmth stems from quality and comfort comes from service
Voice operation instructions