BROCHURE MERI COMMERCIAL HEAT PUMP
CONTENTS
Air Source Heat Pump Water Heater \mathsf { P 1 } \mathsf { - P 5 }
Air Source Heat Pump For Heating and Cooling P6-P8
01 Product Features
02 High-Efficiency Air Source Heat Pump Water Heater
03 Ultra-Low Temperature Air Source Heat Pump Water Heater
01 Product Features
02 Modular Air-Cooled Heat Pump Unit
03 Ultra-Low Temperature Air Source Heat Pump For Heating and Cooling
01 Product Features 02 Ultra-Low Temperature Air Source Heat Pump Heating Unit
01 Product Features 02 High-Efficiency Air Source Heat Pump for swimming pool
High-Efficiency Air Source Heat Pump Water Heater
Performance Features
High Temperature Water Output The maximum water outlet temperature can reach up to 6 0 ^ { \circ } C . . Provide stable and efficient hot water production under various weather conditions.
Intelligent Temperature Control
Achieve smart constant temperature regulation based on key parameters such as ambient temperature, water tank temperature, and water level
Safe and Durable
Does not directly contact the heat transfer medium, fundamentally eliminating potential safety risks such as flammability, explosiveness, and electrical leakage. Low maintenance cost with high reliability and durability.
Low Carbon and Energy Saving
Use electric energy to absorb heat from the air for heating, consuming over 7 5 % less electricity compared to traditional electric heating methods, significantly reducing carbon emissions.
Application
MR Air Source Heat Pump Water Heater
MRCAX Series
High-Efficiency Air Source Heat Pump Water Heater
| MODEL [MRCAX-] | 20S33A | 40D33A | 40S33A | 45S33A | 50S33A | ||
| Normal Operating Condition | Heating Capacity | kW | 18.9 | 37.3 | 37.3 | 44.8 | 49.9 |
| Water Yield | m³/h | 0.41 | 0.80 | 0.80 | 0.96 | 1.07 | |
| Input Power | kW | 4.2 | 8.4 | 8.4 | 10.1 | 11.3 | |
| COP | W/W | 4.50 | 4.44 | 4.44 | 4.44 | 4.42 | |
| Nominal Operating Condition | Heating Capacity | kW | 14.5 | 29.3 | 29.3 | 32.5 | 34.5 |
| Water Yield | m³/h | 0.27 | 0.55 | 0.55 | 0.61 | 0.64 | |
| Input Power | kW | 3.9 | 7.8 | 7.8 | 8.6 | 9.3 | |
| COP | W/W | 3.72 | 3.76 | 3.76 | 3.78 | 3.71 | |
| Power Supply | 380V/3N~50Hz | ||||||
| Max. Input Power | kW | 6 | 13 | 13 | 16 | 18 | |
| Max. Input Current | A | 11 | 25 | 25 | 30 | 34 | |
| Ambient Temperature | ℃ | -12~45 | |||||
| Max. Outlet Temperature | ℃ | 60 | |||||
| Refrigerant | |||||||
| Compressor | High-Efficiency Scroll | R410A | |||||
| Air Side Heat Exchanger | High-Efficiency Copper Tube & Fin Heat Exchanger | ||||||
| Water Side Heat Exchanger | Tube In Tube | ||||||
| Water System | Nominal Water Flow | m³/h | 2.5 | 5.0 | 5.0 | 5.6 | 5.9 |
| Pipe Diameter | DN25(Female) | DN40(Female) | DN40(Female) | DN40(Female) | DN40(Female) | ||
| Water Pressure Drop | kpa | ≤80 | |||||
| Dimension (L*W*H) | mm | 750*750*1100 | 1470*750*1100 | 1020*1100*1820 | 1020*1100*1820 | 1020*1100*1820 | |
| Noise Level | dB(A) | ≤58 | ≤60 | ≤65 | ≤65 | ≤66 | |
| Weight | kg | 135 | 235 | 270 | 290 | 290 | |
High-Efficiency Air Source Heat Pump Water Heater
| MODEL [MRCAX-] | 75D33A | 90D33A | 100D33A | 190D33A | |||
| Normal Operating Condition | Heating Capacity | kW | 74.8 | 89.6 | 99.2 | 187.0 | |
| Water Yield | m³/h | 1.61 | 1.93 | 2.13 | 4.02 | ||
| Input Power | kw | 16.8 | 20.2 | 22.5 | 42.5 | ||
| COP | W/W | 4.45 | 4.44 | 4.41 | 4.40 | ||
| Nominal Operating Condition | Heating Capacity | kW | 58.5 | 65.0 | 69.0 | 136.0 | |
| Water Yield | m³/h | 1.09 | 1.21 | 1.29 | 2.54 | ||
| Input Power | kW | 15.6 | 17.5 | 18.6 | 36.8 | ||
| COP | W/W | 3.75 | 3.71 | 3.71 | 3.70 | ||
| Power Supply | 380V/3N~50Hz | ||||||
| Max. Input Power | kW | 26 | 32 | 36 | 58 | ||
| Max. Input Current | A | 49 | 61 | 68 | 110 | ||
| Ambient Temperature | ℃ | -12~45 | |||||
| Max. Outlet Temperature | ℃ | 60 | |||||
| Refrigerant | R410A | ||||||
| Compressor | High-Efficiency Scroll | ||||||
| Air Side Heat Exchanger | High-Efficiency Copper Tube & Fin Heat Exchanger | ||||||
| Water Side Heat Exchanger | Tube In Tube | ||||||
| Water System | Nominal Water Flow | m³/h | 10.1 | 11.2 | 11.9 | 23.4 | |
| Pipe Diameter | DN50(Male) | DN50(Male) | DN50(Male) | DN65(Flange) | |||
| Water Pressure Drop | kPa | ≤50 | |||||
| Dimension (L*W*H) | mm | 1950*1060*1950 | 1950*1060*1950 | 1950*1060*1950 | 2330*1350*2200 | ||
| Noise Level | dB(A) | ≤68 | ≤70 | ≤70 | ≤75 | ||
| Weight | kg | 550 | 560 | 600 | 920 | ||
Ultra-Low Temperature Air Source Heat Pump Water Heater
| MODEL [MRCAX-] | 20SD33A | 40DD33A | 45SD33A | 50SD33A | ||
| ONerating | Heating Capacity | kW | 18.8 | 38.5 | 45.0 | 50.5 |
| Water Yield | m³/h | 0.40 | 0.83 | 0.97 | 1.09 | |
| Input Power | kW | 4.2 | 8.7 | 10.0 | 11.4 | |
| COP | W/W | 4.48 | 4.43 | 4.50 | 4.43 | |
| Operedng Condition | Heating Capacity | kW | 14.9 | 29.5 | 34.0 | 37.5 |
| Water Yield | m³/h | 0.28 | 0.55 | 0.64 | 0.70 | |
| Input Power | kW | 4.0 | 7.9 | 9.0 | 10.1 | |
| COP | W/W | 3.73 | 3.73 | 3.78 | 3.71 | |
| Nominal Conditin | Heating Capacity | kW | 10.2 | 20.5 | 24.8 | 28.1 |
| Water Yield | m³/h | 0.19 | 0.38 | 0.46 | 0.53 | |
| Input Power | kW | 4.2 | 8.4 | 10.1 | 11.7 | |
| COP | W/W | 2.43 | 2.44 | 2.46 | ||
| Power Supply | 380V/3N~50Hz | 2.40 | ||||
| Max. Input Power | kW | 6 | 13 | 15 | 17 | |
| Max. Input Current | A | 11 | 25 | 28 | 32 | |
| Ambient Temperature | ℃ | -30~45 | ||||
| Max. Outlet Temperature | ℃ | 60 | ||||
| Refrigerant | ||||||
| Compressor | R410A High-Efficiency Scroll | |||||
| Air Side Heat Exchanger | High-Efficiency Copper Tube & Fin Heat Exchanger | |||||
| WaterSide Heat Exchanger | ||||||
| Water System | Nominal Water Flow | m³/h | 2.9 | Tube In Tube | 7.1 | 8.1 |
| DN25(Female) | 5.9 | DN40(Female) | DN40(Female) | |||
| Pipe Diameter Water Pressure Drop | DN40(Female) | |||||
| Dimension (L*W*H) | kPa | ≤80 | ||||
| mm | 750*750*1100 | 1470*750*1100 | 1020*1100*1820 | 1020*1100*1820 | ||
| Noise Level Weight | dB(A) kg | ≤58 140 | ≤60 260 | ≤65 300 | ≤66 300 | |
Ultra-Low Temperature Air Source Heat Pump Water Heater
| MODEL [MRCAX-] | 75DD33A | 90DD33A | 100DD33A | 190DD33A | ||
| Normal Operating | Heating Capacity | kW | 75.0 | 90.0 | 100.0 | 188.0 |
| Water Yield | m³/h | 1.61 | 1.93 | 2.15 | 4.04 | |
| Input Power | kW | 16.9 | 20.3 | 22.7 | 42.7 | |
| COP | W/W | 4.44 | 4.43 | 4.41 | 4.40 | |
| Rated Operating Condition | Heating Capacity | kW | 59.0 | 67.5 | 70.3 | 136.6 |
| Water Yield | m³/h | 1.10 | 1.26 | 1.31 | 2.55 | |
| Input Power | kW | 15.8 | 18.0 | 18.9 | 36.9 | |
| coP | W/W | 3.73 | 3.75 | 3.72 | 3.70 | |
| Nominal Operating Condition | Heating Capacity | kW | 40.3 | 49.5 | 56.0 | 104.0 |
| Water Yield | m³/h | 0.75 | 0.93 | 1.05 | 1.94 | |
| Input Power | kW | 16.7 | 20.5 | 23.3 | 43.3 | |
| COP | W/W | 2.41 | 2.41 | 2.40 | ||
| Power Supply | 380V/3N~50Hz | 2.40 | ||||
| Max. Input Power | kw | 26 | 30 | 34 | 58 | |
| Max. Input Current | A | 49 | 57 | 65 | 110 | |
| Ambient Temperature | ℃ | -30~45 | ||||
| Max. OutletTemperature | ℃ | 60 | ||||
| Refrigerant | R410A | |||||
| Compressor | High-Efficiency Scroll | |||||
| Air Side Heat Exchanger | High-Efficiency Copper Tube & Fin Heat Exchanger | |||||
| Water Side Heat Exchanger | Tube In Tube | |||||
| Water System | Nominal Water Flow | m³/h | 11.6 | 14.2 | 16.1 | 29.8 |
| Pipe Diameter | DN50(Male) | DN65(Flange) | ||||
| Water Pressure Drop | kpa | DN65(Flange) | DN65/DN80(Flange) | |||
| Dimension (L*W*H) | ≤50 | |||||
| mm | 2010*1170*2110 | 2010*1170*2110 | 2010*1170*2110 | 2330*1350*2200 | ||
| Noise Level Weight | dB(A) kg | ≤68 650 | ≤70 700 | ≤70 720 | ≤75 960 | |
Modular Air-Cooled Heat Pump Unit
Ultra-Low Temperature Air Source Heat Pump For Heating And Cooling
Performance Features
Low-Carbon & Energy Efficient
Absorb low-grade heat from the air and convert it into high-grade heat energy, saving over 7 5 % electricity compared to traditional electric heating methods. Use eco-friendly refrigerants with low GWP, zero ODP, non-toxic and odorless—environmentally safe and sustainable.
Safe & Durable
No direct contact with the heated medium, fundamentally eliminating potential safety risks such as flammability, explosion, and electrical leakage. Low maintenance cost, high reliability, and long service life.
Wide Applicability
The modular air-cooled heat pump units operate reliably in ambient temperatures from - 1 2 ^ { \circ } C to 4 5 ^ { \circ } C . The ultra-low temperature air source heat pumps adopt enhanced vapor injection technology and work in environments from - 、 3 5 ^ { \circ } C to 4 5 ^ { \circ } C
Multi-Functional Use
Provide both cooling in summer and heating in winter with one single unit—reducing equipment investment and maximizing utility.
Application
Residential buildings,
villas,
schools,
communities,
hospitals,
supermarkets,
hotels,
clubs,
office buildings,
government facilities,
railway stations, and more.
MR Air Source Heat Pump For Heating and Cooling
MRCAH Series
Ultra-Low Temperature Air Source Heat Pump For Heating and Cooling
| MODEL [MRCAH-] | 40SD33A | 45SD33A | 75DD33A | 80DD33A | 150DD33A | 170DD33A | 290FD33A | ||
| Rated Heating Condition | Heating Capacity | kW | 36.8 | 41.0 | 73.4 | 80.5 | 150.0 | 171.0 | 290.0 |
| Input Power | kW | 10.7 | 12.0 | 21.6 | 23.7 | 44.1 | 50.3 | 86.8 | |
| coP | W/W | 3.44 | 3.42 | 3.40 | 3.40 | 3.40 | 3.40 | 3.34 | |
| Heating Capacity | kW | 25.0 | 28.1 | 50.0 | 54.2 | 99.5 | 110.0 | 195.0 | |
| Heating Condition Low | Input Power | kW | 10.3 | 11.7 | 20.6 | 22.5 | 41.3 | 45.7 | 83.1 |
| cop | W/W | 2.43 | 2.40 | 2.43 | 2.41 | 2.41 | 2.41 | 2.35 | |
| Heating Capacity | kW | 21.0 | 24.8 | 42.5 | 45.9 | 88.0 | 96.5 | 173.0 | |
| Input Power | kW | 10.2 | 12.2 | 21.3 | 23.0 | 44.1 | 48.2 | 89.0 | |
| Temperiature Condition Nominal Heating Condition | COP | W/W | 2.06 | 2.03 | 2.00 | 2.00 | 2.00 | 2.00 | 1.94 |
| Cooling Capacity | kW | 33.0 | 36.5 | 65.3 | 72.3 | 130.0 | 140.0 | 258.0 | |
| Input Power | kW | 11.2 | 12.6 | 22.5 | 25.0 | 45.4 | 48.9 | 92.0 | |
| coP | W/W | 2.95 | 2.90 | 2.90 | |||||
| Power Supply | 2.89 380V/3N~50Hz | 2.86 | 2.86 | 2.80 | |||||
| Max. Input Power | kW | 15 | 17 | 29 | 33 | 57 | 64 | 115 | |
| Max. Input Current | A | 28 | 32 | 55 | 63 | 108 | 122 | 218 | |
| Ambient Temperature | ℃ | -35~45 | |||||||
| Max. Outlet Temperature ℃ | |||||||||
| Refrigerant | 55 | ||||||||
| Compressor | R410A | ||||||||
| Air Side Heat Exchanger | High-Efficiency Scroll | ||||||||
| Water Side Heat Exchanger | High-Efficiency Copper Tube & Fin Heat Exchanger | ||||||||
| Nominal Water Flowm²/h | High-Efficiency Plate Heat Exchanger | High-Efficiency Shell Tube Heat Exchanger | |||||||
| Pipe Diameter | 5.7 | 6.3 | 11.2 | 12.4 | 22.4 | 24.1 | 44.4 | ||
| Water System Water Pressure Drop | kPa | DN40(Female) DN40(Female)DN50(Male) | DN50(Male)DN65(Flange) DN65(Flange)DN100(Flange) | ||||||
| Dimension (L*W*H) | mm | ≤50 | |||||||
| Noise Level | dB(A) | ≤65 | 1020*1100*18201020*100*18202010*1170*21102010*1170*21102330*1350*22002330*1350*23002350*2350*2460 | ||||||
| Weight | kg | 300 | ≤65 300 | ≤70 700 | ≤70 700 | ≤75 1100 | ≤75 1100 | ≤75 2350 | |
Modular Air-Cooled Heat Pump Unit
| MODEL [MRCAH-] | 35S33A | 65D33A | 130D33A | 260F33A | ||
| Nominal Cooling Condition | Cooling Capacity | kW | 33.0 | 65.0 | 131.0 | 262.0 |
| Input Power | kW | 10.5 | 20.5 | 42.0 | 84.0 | |
| COP | W/W | 3.14 | 3.17 | 3.12 | 3.12 | |
| Nominal Heating Condition | Heating Capacity | kW | 36.8 | 68.0 | 136.0 | 272.0 |
| Input Power | kW | 10.7 | 20.0 | 40.0 | 80.0 | |
| Cop | W/W | 3.44 | 3.40 | 3.40 | 3.40 | |
| Power Supply | 380V/3N~50Hz | |||||
| Max. Input Power | kW | 14 | 27 | 52 | 104 | |
| Max. Input Current | A | 27 | 51 | 99 | 198 | |
| Ambient Temperature | ℃ | -12~45 | ||||
| Max. Outlet Temperature ℃ | 55 | |||||
| Refrigerant | R410A | |||||
| Compressor | High-Efficiency Scroll | |||||
| Air Side Heat Exchanger | High-Efficiency Copper Tube & Fin Heat Exchanger | |||||
| Water Side Heat Exchanger | High-Efficiency Plate Heat Exchanger | High-Efficiency Shell Tube Heat Exchanger | ||||
| Water System | Nominal Water Flow | m³/h | 5.7 | 11.2 | 22.5 | 45.1 |
| Pipe Diameter | DN40(Female) | DN50(Female) | DN65(Male) | DN80(Flange) | ||
| Water Pressure Drop | kpa | ≤50 | ||||
| Dimension (L*W*H) | mm | 1020*1100*1820 | 2100×1050×1950 | 2300×1150*2230 | 2300×2300*2230 | |
| Noise Level | dB(A) | ≤65 | ≤70 | ≤75 | ≤75 | |
| Weight | kg | 300 | 700 | 925 | 1711 | |
Ultra-Low Temperature Air Source Heat Pump Heating Unit
Performance Features
Green & Low Carbon
Save over 6 0 % energy compared to traditional electric heating methods. Use next-generation eco-friendly refrigerant with low GWP, zero ODP, non-toxic, and odorless—both energy-saving and environmentally friendly
Safe & Durable
No direct contact with the heated medium, fundamentally eliminating safety hazards such as flammability, explosion, or electric leakage. Low maintenance and high reliability.
Stable Operation in Extreme Cold
Equipped with enhanced vapor injection (EVI) technology, the units operate efficiently in ambient temperatures as low as \angle 3 0 ^ { \circ } C to 2 5 ^ { \circ } \mathsf { C } . . Deliver strong heating performance even in harsh cold climates.
High-Temperature Heating for Cold Regions
Provide stable high-temperature heating above 5 5 ^ { \circ } C in severe winter conditions. Compatible with all terminal systems, especially suitable for retrofitting older buildings with cast iron radiators in northern areas.
Application
Villas,
schools,
residential communities,
hospitals,
supermarkets,
hotels,
clubs,
office buildings,
government facilities,
and older public buildings such as railway stations.
MR Air Source Heat Pump Heating Unit
MRCAR Series
Ultra-Low Temperature Air Source Heat Pump Heating Unit
| MODEL [MRCAR-] | 40SD33A | 45SD33A | 75DD33A | 80DD33A | 150DD33A | 170DD33A | 290FD33A | ||
| Rated Heating Input Power | Heating Capacity | kW | 38.8 | 44.8 | 74.4 | 79.3 | 148.3 | 170.0 | 290.0 |
| kW | 11.4 | 13.0 | 21.8 | 23.5 | 44.3 | 50.7 | 86.8 | ||
| COP | W/W | 3.40 | 3.45 | 3.41 | 3.37 | 3.35 | 3.35 | 3.34 | |
| Heating Capacity | 25.5 | 28.8 | 50.5 | 54.7 | 102.0 | 110.6 | 200.0 | ||
| Nominal Heating Condition ① | Input Power | kW | 12.1 | 13.6 | 23.8 | 25.9 | 48.6 | 52.9 | 99.0 |
| COP | W/W | 2.11 | 2.12 | 2.12 | 2.11 | 2.10 | 2.09 | 2.02 | |
| Heating Capacity | kW | 25.0 | 28.1 | 50.0 | 54.2 | 99.5 | 110.0 | 195.0 | |
| Input Power | kW | 10.3 | 11.7 | 20.6 | 22.5 | 41.3 | 45.8 | 83.1 | |
| Condition ② Low | COP | W/W | 2.43 | 2.40 | 2.43 | 2.41 | 2.41 | 2.40 | 2.35 |
| Heating Capacity | kW | 22.6 | 25.4 | 43.3 | 46.9 | 88.4 | 96.2 | 184.0 | |
| Input Power | kW | 12.4 | 13.8 | 23.9 | 26.0 | 49.1 | 53.4 | 103.4 | |
| COP | W/W | 1.82 | 1.84 | 1.81 | 1.80 | 1.80 | 1.80 | ||
| Condition Power Supply | 1.78 | ||||||||
| Max. Input Power | kW | 15 | 17 | 28 | 380V/3N~50Hz | 58 | 64 | 120 | |
| Max. Input Current | A | 28 | 32 | 53 | 34 65 | 110 | 122 | 228 | |
| Ambient Temperature | ℃ | -35~25 | |||||||
| Max. Outlet Temperature | ℃ | 60 | |||||||
| Refrigerant | R410A | ||||||||
| Compressor | |||||||||
| Air Side Heat Exchanger | High-Efficiency Scroll High-Efficiency Copper Tube & Fin Heat Exchanger | ||||||||
| Water Side Heat Exchanger | |||||||||
| Nominal Water Flowm³/h | 4.4 | 5.0 | 8.7 | Tube In Tube 9.4 | 17.5 | 19.0 | 34.4 | ||
| Pipe Diameter | DN40(Female) DN40(Female) DN65(Flange)DN65(Flange)DN65(Flange)DN65(Flange) DN80(Flange) | ||||||||
| Water Pressure Drop | kPa | ||||||||
| Dimension (L*W*H) | mm | 1020*1100*18201020*1100*1820 | ≤50 | 2010*1170*21102010*1170*21102330*1350*2200 | 2330*1350*23002350*2350*2460 | ||||
| Noise Level | dB(A) | ≤65 | ≤65 | ≤70 | ≤70 | ≤75 | ≤75 | ≤75 | |
| Weight | kg | 320 | 320 | 740 | 760 | 960 | 970 | 2150 | |
High-Efficiency Air Source Heat Pump For Swimming Pool
Performance Features
Green & Low Carbon
Utilize heat from ambient air for water heating, saving over 80 % energy compared to traditional electric heating methods. Use next-generation eco-friendly refrigerant with low GWP and zero ODP—efficient and environmentally responsible.
Safe & Reliable
Water and electricity are completely separated. No combustion, no leakage, no emissions—eliminating safety risks such as fire, explosion, electric shock, or poisoning associated with traditional heating systems.
Durable & Long-Lasting
Equipped with a titanium heat exchanger that resists ammonia ion corrosion, acid, and chemical damage. Offer over 10 years of reliable performance and is completely safe for human health.
Precise Temperature Control
Advanced control system ensures real-time monitoring of pool water temperature, maintaining consistent and comfortable water conditions.
Application
Resorts,
villas,
residential communities,
hotels,
clubs,
amusement parks, and more.
MR Air Source Heat Pump For Swimming Pool
MRCAY Series
High-Efficiency Air Source Heat Pump For Swimming Pool
| MODEL [MRCAY-] | Normal | 20S33A | 50S33A | 95D33A | 190D33A | ||
| Ultra Low-temp. | 20SD33A | 50SD33A | 95DD33A | 190DD33A | |||
| Nominal Operating Condition | Heating Capacity | kw | 20.0 | 47.0 | 95.0 | 190.0 | |
| Input Power | kW | 4.0 | 9.4 | 19.0 | 38.0 | ||
| CoP | W/W | 5.00 | 5.00 | 5.00 | 5.00 | ||
| Low Teperatugre Condition | Heating Capacity | kW | 15.8 | 39.6 | 80.0 | 160.0 | |
| Input Power | kw | 3.6 | 9.1 | 18.4 | 37.0 | ||
| cop | W/W | 4.39 | 4.35 | 4.35 | 4.32 | ||
| Power Supply | 380V/3N~50Hz | ||||||
| Max. Input Power | kw | 5.5 | 13 | 26 | 55 | ||
| Max. Input Current | A | 10 | 25 | 49 | 104 | ||
| Ambient Temperature | ℃ | -30~45(Ultra Low-Temp.)/-12~45 (Normal) | |||||
| Max. Outlet Temperature | ℃ 45 | ||||||
| Refrigerant | R410A | ||||||
| Compressor | High-Efficiency Scroll | ||||||
| Air Side Heat Exchanger | High-Efficiency Copper Tube & Fin Heat Exchanger | ||||||
| Water Side Heat Exchanger | Titanium Heat Exchanger | ||||||
| Water System | Nominal Water Flow | m³/h | 3.4 | 8.1 | 16.3 | 32.7 | |
| Pipe Diameter | DN32(Female) | DN40(Female) | DN65(Flange) | DN80(Flange) | |||
| Water Pressure Drop | kpa | ≤50 | |||||
| Dimension (L*W*H) | mm | 750*750*1100 | 1020*1100*1820 2010*1170*2110 | 2330*1350*2200 | |||
| Noise Level | dB(A) | ≤65 | ≤65 | ≤70 | ≤75 | ||
| Weight | kg | 180 | 360 | 680 | 1200 | ||
MR C A H V 100 S H D 1 1 A Version: A-1st Edition,B-2nd Edition, C-3rd Edition... and so on Power Supply: 1-1N220V/50HZ,2-3N380V/60HZ, 3-380V/50HZ,4-460V/60HZ,5-Other Refrigerant: 1-R134a,2-R32,3-R410A,4-R404A,5-R454 B, 6-R513A,7-R515B,8-R1234yf,9-R1234ze(E),A-R123 3zd (E),Z-Other Heat Source Side Type: D-Low Temp., E-Waste Heat Recovery, Omitted-Standard or None User Side Type:M-Medium Temp., H-High Temp., U-Ultra High Temp., Omitted-Normal Temp. (Heating) Compressor Quantity: S-Single, D-Double, T-Triple, F-Four, W-Five, L-Six, E-Eight, G-Other Rated Cooling (Heating) Capacity: 100 kW Various Frequency Available: V-Yes Omitted - No Application: H-Heat Pump, R-Single Heat, S-Hot Water Primary Heating, X-Hot Water Circulating Heating, Y-Swimming Pool, D-Combined Heating and Cooling Supply Cooling (Heat Source) Type: A-Air-cooled (Air Source), W-Water-cooled (Water Source) Compressor Type: C-Scroll, R-Rotary, F-Cascade, P-Piston Company: MR-MERI
1. R410A High-Efficiency Air Source Heat Pump Water Heater: MRCAX-75D33A;
2. R410A Ultra-Low Temperature Air Source Heat Pump Heater: MRCAR-150DD33A;
3. R410A Ultra-Low Temperature Air Source Heat Pump For Heating and Cooling: MRCA H-75DD33A;
4. R410A High-Efficiency Air Source Heat Pump Water Heater: MRCAY-95D33A.
APPLICATION
| TypeofWater Heating Equipment | Electric Boiler | GasBoiler | Fuel Oil Boiler | Solar Energy System With Electric Backup | MERI Heat Pump |
| Energy Type | Electricity | Natural Gas | Diesel | Solar Energy+ ElectricityAir Source + Electricity | |
| Energy Calorific Value | 860kcal/kW·h | 9,200kcal/m3 | 10,300kcal/kg | 860kcal/kW·h | 860kcal/kW·h |
| Heat Conversion Efficiency | 95% | 90% | 90% | 250% | 420% |
| Energy Unit Price | ¥0.72/kW·h | ¥3.00/m3 | ¥7.80/kg | ¥0.72/kW·h | ¥0.72/kW·h |
| Daily Energy Consumption | 490.0kW·h | 48.3m3 | 43.2kg | 196.0kW·h | 116.7kW·h |
| Daily Energy Cost (RMB) | ¥352.8 | ¥144.9 | ¥337.0 | ¥141.1 | ¥84.0 |
| Annual Energy Cost (RMB) | ¥128,800 | ¥52,900 | ¥123,000 | ¥51,500 | ¥30,700 |
| Environmental Friendliness | Pollution Free | Emissions from combustion | Heavy Pollution | Pollution Free | Pollution Free |
| Safety | Risk of electric leakage | fires andexplosions | Risks foileaksiges | Rsk of electriumetube, rupture | Safe and reliable |
Remarks:Based on hot water production of 10 tons/day, ambient temperature 20°C, inlet water temperature 15°C, outlet water temperature 55°C, and annual operating time 365 days.
F
| Heating Equipment | Electric Boiler | GasBoiler | Fuel Oil Boiler | MERI Heat Pump |
| Total Daily Heat Capacity | 10,320,000 kcal | 10,320,000 kcal | 10,320,000 kcal | 10,320,000 kcal |
| Energy Calorific Value | 860kcal/kW·h | 9,200kcal/m3 | 10,300kcal/kg | 860kcal/kW·h |
| Heat Conversion Eficiency | 95% | 80% | 90% | 300% |
| Energy Unit Price | ¥0.72/kW·h | ¥3.00/m3 | ¥7.80/kg | ¥0.72/kW·h |
| Daily Energy Consumption | 12,631.6kW·h | 1402.2m3 | 1,113.3 kg | 4,000.0 kWh |
| Daily Energy Cost (RMB) | ¥9094.7 | ¥4206.5 | ¥8,683.5 | ¥2,880.0 |
| Total Heating Seasonal Cost (RMB) | ¥1,091,400 | ¥504,800 | ¥1,042,000 | ¥345,600 |
| Heating Season Cost per m² | ¥109.1 | ¥50.5 | ¥104.2 | ¥34.5 |
Remarks:The heating system is designed for a total area of 10,000 square meters, with a heating season of 120 days. The design heating load is 50W/m².
CUSTOMER SERVICE
Choose MERI heat pump units and enjoy comprehensive, thoughtful service from meticulous pre-sales consultation to professional installation and worry-free after-sales support. We understand that every bit of warmth is closely tied to the comfort of our users' lives. That’s why we dedicate our efforts to every step, ensuring the heat pump system operates efficiently and remains durable.
Pre-sales: Conduct technical research to determine parameters and details, clarify project requirements, and provide comprehensive product introductions along with customized solutions.
During sales: Deploy a professional team for precise installation, ensure waterproof and anti-collision packaging to avoid damage, and provide full logistics tracking to optimize performance.
After-sales: Available 24/7 to respond quickly to any customer needs.