ZPW-2000S Jointless Track Cicuit is a basic signalling safety equipment that uses the rail as the transmission medium.
Its major functions are as follows:
The block diagram of the track circuit system principle is as follows:
ZPW-2000S Jointless
Track Circuit Equipment
System Function
· Provide track section occupied/clear status information for the trackside signalling system.
· Broken rail detection (when a rail break occurs and results in an electrical open cricuit).
· Continuously transmit 18 types of real-time low-frequency control information to the onboard equipment.
Train Signal Antenna
Indoor Data Acquisition
Outdoor Data
Acquisition
Outdoor
Indoor
Compensation Capacitor
Outdoor
Equipment
Outdoor
Equipment
Centralized Monitoring Communication Unit / Relay Coding Condition
Indoor Acquisition Equipment Indoor Receiving Equipment Indoor Sending Equipment
Monitoring and Diagnostic Equipment
Signal Cable Signal Cable
ZPW-2000S equipment, developed by HollySys,
supports both communication coding and
relay coding, and is applicable to high-speed,
conventional, and intercity railway lines.
01.\"2oo2×2\" Hardware Redundancy Structure
The system adopts a \"2oo2×2\" hardware redundancy structure, with indoor control units integrating two sets of CPUs. The confi gured
dual control units form a dual-machine operation and hot standby system, ensuring higher safety and reliability.
02.Double Safety Check
The system employs double safety check
technology with added internal check loops
between the sender and the receiver to double
check the frequency shift signal of the indoor
and outdoor loops. It can protect the crosstalk
of frequency shift signal, thereby improving the
safety of the system.
03.Outdoor Equipment Dual Isolation Redundant Protection
The outdoor equipment employs a dual isolation protection design. Auxiliary tuning units and tuning matching units are installed at the
mechanical insulation joints at both ends of the platform track. When the mechanical insulation is damaged or the tuning matching unit
malfunctions, this can ensure safe transmission of the outdoor frequency shift signal.
Technical Features
Frequency
Shift Signal
Outdoor
Track Loop
Indoor
Loop
Sender
Receiver
Analog
Network
Analog
Network
Outdoor
Equipment
Frequency
Shift Signal
Air Core Coil
Primary
Protection
Secondary
Protection
Tuning
Matching Unit
Air Core Coil
Tuning
Matching Unit
Auxiliary
Tuning Unit
Choke
Transformer
Choke
Transformer
High Safety and Reliability
The system adopts intelligent remote maintenance technology, equipped with monitoring and diagnosis devices. It features indoor and
outdoor monitoring, visual display of station and equipment status, data and curve query, early warning of equipment abnormalities, fault area
diagnosis, on-site maintenance guidance, historical data playback, and centralized monitoring and communication. These functions enable
remote fault diagnosis and precise location of track circuit failures, enhance capabilities in intelligent analysis, operations, maintenance, and
decision-making, reduce fault delays, and improve transportation effi ciency.
Maintenance Friendly
The system adopts an integrated design, with the indoor equipment incorporating an analog network, direction switching circuits, analog
signal acquisition circuits, current sensors, and alarm relays. This reduces external cable connections, saves corresponding relays, simplifi es
installation, effectively reduces project costs, and facilitates engineering design, implementation, and maintenance.
High Integration and Easy Installation
Analog Signal
Acquisition
Sending Analog
Network
Current
Sensor
Receiving Analog
Network
Alarm
Relay
Direction
Switching Circuit
Channel Acquisition Main Receiver Parallel Receiver Main Sender Standby Sender Redundancy Switch Analog Network
SIL4 certifi cate from
Ricardo Certifi cation
First Prize for Scientifi c and Technological
Progress from China Communications and
Transportation Association
Invention Patents
Certifi cate of Railway Transport
Infrastructure Equipment Manufacturer
from National Railway Administration of
the People's Republic of China
Railway product certifi cates from
CRCC(China Railway Test &
Certifi cation Center)
Qualifi cations and Honors
Applied Cases
· Xingguo-Quanzhou Railway · Guiyang South-West Ring Railway
· Chengxiang Railway Station · Jingbian-Shenmu Railway
· Chengdu-Ya'an Railway · Beijing Fengshuang Railway
· Shenyang-Dalian Railway · Jining-Datong-Yuanping High-speed Railway
· Zibo-Boshan Railway · Baotou-Yinchuan High-speed Railway
· Shijiazhuang-Taiyuan High-speed Railway · Lanzhou-Zhangye No.3 & No.4 Line High-speed Railway
ZPW-2000S Track Circuit Products have been applied to 24
railways worldwide, supporting diverse railway line types with
operating speeds ranging from 120 km/h to 350 km/h and
covering a total distance of 1286 kilometers.