Instrument Brochure
Leaders in Optical Sensing
for Gas Detection
Innovative Technology
Precise and Efficient
Safe and Reliable
High Precision Manufacturing
CONTENTS
Company Profile 03
Technology Advantage 07
Product Introduction
Gas Safety Monitoring Solution
Industrial Gas Safety Monitoring System 09
Natural Gas Safety Monitoring System 11
Universal Gas Detection
GB8 Fixed Gas Detector GB8 13
XA8 Open Path Gas Detector XA8 15
XH8 Open Path Gas Detector XH8 17
XG8 Open Path Gas Detector XG8 19
AA6 Gas Alarm Controller AA6 21
Gas Alarm Controller A-711-B01 23
XB8 Laser Gas Remote Sensing Detector XB8 25
XD8 Laser Gas Remote Sensing Detector XD8 27
BA8 Portable Gas Detector BA8 29
Portable Multi-Gas Detector BB9 31
Coal Mine Gas Detection
Coal Mine Laser Gas Detector GJJ100B-INTL 33
Mining Laser Methane Power Failure Device DJJ100/127-INTL 35
Coal Mine Portable Laser Gas Detector BA8 37
Detector Intelligent Charging Cabinet CLF-50WG-INTL 39
Coal Mine Portable Laser Gas Detector BC8 41
Coal Mine Laser Methane Remote Sensing Detector XB8 43
Optional Components
Gas Sampling Pump TX1000-INTL 45
Optical Reflector TX3000-INTL 47
Calibration Gas Box TX4000-INTL 48
ABOUTCOMPANY
HXTX Sensing Technology (Dalian) Co., Ltd., a wholly-owned subsidiary of HXTX Group, was established in March 2019 with a registered capital of 136 million RMB. The company is committed to the research and development of optical detection technology, so that life away from the harm of harmful gases, vision to become the optical technology leader in the field of gas detection.
HONOR QUALIFICATION
· High Tech Enterprises
· Intelligent Factory in Liaoning Province
· Liaoning Province Eagle Enterprise
· Dalian No Waste Factory
· Dalian Green Manufacturing Factory
· Liaoning Province Green Manufacturing Factory
· Dalian Technology-based Small and Medium-sized Enterprises
· Innovative Small and Medium Sized Enterprises in Liaoning Province
· Liaoning Province's Technology-based Small and Medium-sized Enterprises
· Liaoning Province Advanced-Level Intelligent Factory
· AAA level Integrated Management System
· Liaoning Province's Specialized, Refined, Unique, and Innovative Small and Medium-sized Enterprises
· National Enterprise of Product/Service Quality & Integrity Commitment
· Dalian Demonstration Enterprise for Collaborative Transformation and Development of Industrialization and Informatization
· Liaoning Province's Pilot Unit for Implementing The Integrated Management System of Informatization and Industrialization
· Dalian Digital Green Collaborative Transformation Developmen Demonstration Enterprise
· The 4th Safety Science and Technology Progress Award of China Association of Work Safety
Expert in optical sensor specialize in gas detection
The main business includes the development and production of ga detection instruments based on laser technology, industrial gas safet monitoring system and so on. The products are mainly used in ga measurement and safety monitoring in coal mine, petroleum an petrochemical, natural gas and environmental protection fields, an provide technical support and service of sensing layer for smart safet supervision, smart city and smart mine.
The company has 100,000 ultra-clean production workshop and th first fully automatic laser gas sensor production line in China, witl independent research and development and mass production capacit of laser sensing products, master the manufacturing process an technology of laser and other core devices.
AAA Enterprise,Credit RatingCertified by SGS, TÜV Rheinland, etc. National patents | 46, Invention patent | 9 R&D achievements recognized as "Internationally Leading" by China Association of Work Safety
Cutting Edge Manufacturing Leading Industry Standards
Build a highly automated and digital intelligent factory based on Industry 4.0 standards, achieving comprehensive connectivity from the equipment layer to the informationlayer.
With the help of MES system, we can achieve full traceability from raw material storage, production process control to finished product delivery, ensuring transparency and controllability of quality and process.
Registered capital 136 Million CNY
Factory area occupied
Automated Assembly Center
The 2500+square meter modern assembly center has fully deployed MES intelligent production management system, achieving high automation at the equipment level and seamless integration at the information level. Not only has it achieved automation control, visual monitoring, and digital management of the entire production and assembly process of core products, but it has also significantly improved production efficiency and product quality, ensuring that every product leaving the factory has excellent performance and reliability.
Production workshop actual shooting
1
Created China's inaugural fully-automated laser gas sensor production line.
2
Master the production and manufacturing process and technology of core optical devices.
3 Independently researches develops and mass-produces laser-based gas detection products
Tunable Diode Laser Absorption Spectroscopy
• Technology Advantage
| Gategory | Laser | NDIR | Catalytic/Electrochemical | Semiconductor | |
| Measurement Precision | √√ | √√ | V | V | |
| Moisture Resistance | √√ | × | × | × | |
| Sensitivity & Range | √√ | √√ | x | V | |
| Remote Detection Capability | √√ | √ | x | × | |
| Intrinsically Safe & EMC | √√ | V | x | x | |
| Gas Mono-selectivity | √√ | V | x | x | |
| Response Time | √√ | V | V | × | |
| Operating Life | √√ | √ | x | V | |
| √√=Excellent √ = Good × = Bad | |||||
Product Type
Industrial Gas Safety Monitoring System
System Introduction
The IGSM System is a set of intelligent safety monitoring system developed based on TDLAS laser technology. The application of laser gas detection technology enables the IGSM system to solve the pain points of traditional technology products such as high negative rate, large project investment, large maintenance, high management difficulty and high construction risk. Can be widely used in metal smelting, petrochemical, glass ceramics, electric power, metallurgy, pharmaceutical, food, tobacco and many other industrial fields, the IGSM system topology diagram is shown below.
Application Site
Combined with the on-site pain point needs and related technical analysis, the project team adopted laser gas detection technology as the design basis and formulated targeted solutions, as follows :
① Using the reflection characteristic of laser, the special position can be monitored at a long distance without contact
Laser-sensing risks, intelligently guarding industrial safety.
② The IGSM system platform is used for centralized management of data visualization and upgrading management methods
Natural Gas Safety Monitoring System
System Introduction
The NGSM System is composed of laser methane detection equipment, control cabinet and system software, among which the laser methane detection equipment is the core equipment of the NGSM System. The product is designed based on TDLAS laser gas detection technology, and the absorption amount of light molecule gas of specific wavelength is analyzed and calculated by harmonic algorithm, so as to realize long-distance and non-contact methane gas detection. The NGSM System can realize real-time monitoring and early warning of natural gas leakage disasters and realize 7×24 hours unattended, which can not only improve the inspection efficiency, reduce the pipeline monitoring cost, but also avoid the safety risks caused by human negligence and error. Once the production unit leaks, on-site personnel can obtain relevant information in the first time. Implement security measures and emergency plans in a timely manner. The following shows the system topology.
System Solution Schematic Diagram
System Characteristic
① The use of advanced laser gas detection technology, 7x24 hours for large area coverage monitoring.
2 Set explosion-proof video andgas detection function as one, 360° Rotating line-type optical beam gas detector No dead Angle monitoring No dead Angle monitoring.
③ Fixed point automatic cruise can be set to achieve unattended.
4 The platform software can realize customized intelligent AI functions such as perimeter and helmet recognition.
⑤ Highly selective to methane gas, not affected by other gases and weather, low false alarm rate.
6 Support solar power supply, wireless communication function, adapt to various special scenarios.
Alarm Configuration and Recording
Application Scenario
Digital-Intelligent Platform
On Site Concentration and Video Monitoring
Video Recording and Playback
Historical Query and Tracing
GB8 Fixed Gas Detector GB8
Application Features
Industrial 24/7 Monitoring
• TDLAS-based CH4 detection (full-scale coverage)
• -40°C to +70°℃ outdoor-rated operation
Zero-Maintenance Operation
• Lifetime calibration-free with embedded diagnostics
• Sensor poisoning immunity | Humid/dust-resistant performance
Specification
Sampling Method Passive Diffusion
Measuring Range 0-100 %LEL
Accuracy
0-60 %LEL:±3% F.S
60-100 %LEL:±5% F.S
Resolution
1%LEL
Response Time (T90)
≤25s
Display Type
7-segment LED
Alarm Sound Level
>80 dB @ 1m
Environmental Parameters
• Operating Temperature
Indoor Type: -10-55 °C
Outdoor Type: -40- 70°C
• Storage Temperature
-40-70℃
• Operating Humidity
≤98%
• Operating Pressure
80kPa-116kPa
Power Specifications
• Input Voltage
12-24VDC
• Power Consumption
<3W
Communication Specifications
• Communication Interface
4-20mA(Default) or RS485 / LoRa
• Communication Protocol
Modbus RTU
Mechanical Construction
• Shell Material
Aluminium Alloy
• Ingress Protection IP66
•Weight 2.1kg
Smart Integration
• Modbus RTU & 4-20mA/RS485 DCS-ready
• IR remote setup (no manual adjustments in hazardous zones)
Intrinsic Safety
• High Safety Level Certification, IP66 High Protection Rating
• Anti-corrosion alloy for oil/gas environments
Equipment Functions
Laser Methane Detection(Custom gases)
Over-Limit Alarm
Areas of Application
Oil & Gas Production
• Real-time CH4 monitoring on drilling platforms
• Fracking zone combustible gas early warning
Pipeline Integrity
• 24/7 leak detection at valve stations
• Subsea pipeline end terminal protection
Storage Facilities
• LNG tank containment area risk assessment
• Tank truck loading zone gas dispersion monitoring
Industrial Processes
• Chemical reactor CH₄ accumulation alerts
• Biogas upgrading plant concentration control
Urban Infrastructure
• Utility tunnel gas monitoring networks
• Landfill gas collection safety systems
Certifications
Explosion Protection
• China Ex
•ATEX
-Ex db ib IIC T6 Gb
-Ex II 2G Ex d IIC T6 Gb
-Ex ib tb IIIC T80C Db
| Laser | CH4 | co | CO2 | H2S | C2H2 | O2 | HCL |
| Infrared | CO2 | C3H8 | |||||
| Electrochemistry | co | O2 | H2 | HCL | H2S |
XA8 Open Path Gas Detector XA8
Application Features
Point & Path Fusion, Dual Verification
• Combines diffusion and remote sensing for wide coverage and precise quantification
• Dual-mode design detects both large-scale dispersion and minor leaks
Independent Pod, Flexible Alignment
• Remotely adjustable module for precise targeting without moving main unit
• Upgraded structure enables reliable one-person on-site setup
Specification
Sampling Method Open Path+Passive Diffusion
Measuring Range 0-100,000 ppm·m (Line Type)
0-100 %LEL (Point Type)
Accuracy ±20% @Standard Reflective Surface
(Line Type)
0-60%LEL:±3% F.S (Point Type)
60-100%LEL:±5% F.S (Point Type)
Response Time (T90) < 1s (Line Type)
≤25s (Point Type)
Display Type Color LCD
Environmental Parameters
• Operating Temperature -10-50℃
• Storage Temperature -40-60℃
• Operating Humidity ≤98%
• Operating Pressure 80kPa-116kPa
Power Specifications
• Input Voltage 12-24 VDC
• Power Consumption ≤6W
Communication Specifications
• Communication Interface 4-20mA(Default) or RS485 / LoRa
• Communication Protocol Modbus RTU
Safety Classification
• Detection Beam CLASS I
• Alignment Beam CLASS IIIR
MechaLaser
• Shell Material
Aluminum alloy
• Ingress Protection IP68
·Weight 2.2kg
Long-Range Tracking, Second-Level Response
• 60 m non-contact optical path with <1 s response for linked control
• Laser technology resists interference, filters moisture/dust, zero false alarms
Pre-Calibrated, Plug-and-Play
• Factory pre-calibrated with standard Modbus/4-20mA interfaces
• Compact, maintenance-free design fits confined spaces
Equipment Functions
Dual-mode Point/Line Monitoring (Gas Customizable)
Rapid Leak Detection and Alarm
Flexible Adjustable Monitoring Direction
Hidden-bay Magnetic Pen System
Areas of Application
Natural Gas Stations & Valve Rooms
• High-precision point quantitative monitoring for complex valve rooms
• Utilizes open optical path for long-distance monitoring across station areas
LNG Storage Tank Areas & Pump Houses
• Precision monitoring of key leakage sources such as compressors and pump units
• Wide optical path coverage for tank perimeters and loading/unloading platforms
Oil & Gas Field Wellhead Stations
• Long-distance optical path for integrated monitoring of multiple wellheads with single-device control
• Efficiently addresses leakage localization and coverage challenges in dense well clusters
High-Value Equipment Protection
• Dual monitoring for core high-value equipment like gas turbines and booster compressors
• Close-range concentration measurement combined with long-range diffusion tracking and early warning
Certifications
Explosion Protection
• China Ex
-Ex db ib lIC T6 Gb
-Ex td ib llC T80C Db
| Laser | CH4 | NH3 | C2H2 | CO | CO2 | HCL | O2 |
\* Optional accessories are detailed on page 47.
Unit: mm
XH8 Open Path Gas Detector XH8
Application Features
Long-Range Detection
• TDLAS Non-Contact Monitoring , 500 m Reflection Path Full Coverage
• Instant 1s alarm triggering with Front-Back Mirrored Display System
Industrial Protection
• IP68 & 304/316L stainless steel
• Modbus RTU cascade alarm networks
Harsh Environment
• AGC anti-fouling: Rain/snow/dust compensation
• Signal penetration through heat haze/smoke
Specification
Sampling Method
Path Lengths
Open Path
120m(Diffuse Reflection)
500m (with Retroreflector)
Measuring Range
0-100,000 ppm·m
Accuracy
±20% @Standard reflective surface
Response Time (T90)
< 1s
Display Type
Color LCD
Environmental Parameters
• Operating Temperature -20-60℃
• Storage Temperature -40-60℃
• Operating Humidity
≤98%
• Operating Pressure
80kPa-116kPa
Power Specifications
• Input Voltage
100–240 VAC, 50/60 Hz
• Power Consumption
≤15W
Communication Specifications
• Communication Interface
RS485(Default) or Fiber or Ethernet
• Communication Protocol
Modbus RTU (RS485)
Modbus TCP (Fiber/Ethernet)
Relay Characteristics
• Contact Form
SPST-NO
(Single Pole Single Throw, Normally Open)
• Contact Rated Load
1A@DC30V
0.15A@AC220V
Laser Safety Classification
• Detection Beam
• Alignment Beam
CLASS I
Mechanical Construction
CLASS IIIR
• Shell Material
304 Stainless Steel
(Customizable 316L Stainless Steel)
• Ingress Protection
•Weight
IP68
13kg
Equipment Functions
Non-contact Laser Methane Long-range Monitoring(Custom Gases)
Relay Output Function
Front-Back Mirrored Display System
Field Data Display and Alarm Function
Areas of Application
Energy Facilities
• LNG tank 500m-level boundary alerts
• Gas storage linear path monitoring
Urban Gas
• Pipeline crossing directional sentry
• City gate station overflow alarms
Industrial Safety
• Steel plant coke gas linear tracking
• Landfill biogas migration monitoring
Emergency Response
• Oilfield perimeter long-range alerts
• Hazard containment directional setup
Certifications
Explosion Protection
• China Ex
-Ex db IIC T6 Gb
| Laser | CH4 | NH3 | C2H2 | co | CO2 | HCL | O2 |
Open Path Gas Detection
\* Optional accessories are detailed on page 47.
XG8 Open Path Gas Detector XG8
Application Features
Intelligent Scanning
• Rain/fog-resistant TDLAS detection
• Pan-tilt trajectory tracking & leak pinpointing
Dual Explosion Proof
• Ex d & Ex tD certifications for gas/dust zones
• IP68 protection for harsh environments
Rugged Deployment
• Pre-calibrated & solar-ready
• 304/316L Stainless steel for chemical resistance
Specification
Sampling Method Path Lengths
Measuring Range Accuracy Response Time (T90) Camera Parameter
Maximum Cruise Points
Environmental Parameters
• Operating Temperature
• Storage Temperature
• Operating Humidity
• Operating Pressure
Power Specifications
• Input Voltage
• Power Consumption
• Start-up Current
• Communication Interface
Communication Specifications
• Communication Protocol
0-100,000 ppm·m
Open Path
±20% @Standard reflective surface < 0.1s
120m(Diffuse Reflection)
500m (with Retroreflector)
1/2.8"CMOS,2 million pixels,
1920×1080,25X optical zoom
255
-40-60℃ -40-60℃ ≤95% 80kPa-110kPa
100–240 VAC, 50/60 Hz
≤75W < 1.5A
RS485 CH1 (Concentration)
RS485 | CH2 (PTZ Control)
Laser Safety Classification
ETH 10/100/1000M (Video)
Modbus RTU @CH1
PELCO-D/P @CH2
• Detection Beam
TCP/IP @ETH
• Alignment Beam
Motion Characteristics
CLASS I
CLASS IIIR
• Horizontal Range
• Horizontal Rotation Speed
360° Continuous Rotation
• Vertical Range
0.1 °- 40 °/S Smooth Variable Speed Rotation
• Vertical Rotation Speed
-90°-+90°
Mechanical Construction
0.1°-30°/S Smooth Variable Speed Rotation
• Shell Material
304 Stainless Steel
• Ingress Protection
(Customizable 316L Stainless Steel)
•Weight
IP68
35kg
Equipment Functions
Non-contact Laser Methane PTZ Scanning Monitoring (Custom gases)
HD Camera with Instant Photo Capture
Dual-Wiper Auto-Cleaning System
24/7 Autonomous Operation with PC software
Areas of Application
Oil & Gas
• Wellhead monitoring & perimeter scanning
• Compressor plant gas dynamic tracking
Chemical Storage
• Tank farm emission boundary alerts
• Loading zone dispersion path analysis
Urban Gas
• Pipeline concentration visualization
• LNG station explosion-proof zone alarms
Industrial Safety
• Refinery perimeter protection systems
• Power plant combustible gas detection
Mobile Solutions
• Fleet-based rapid source identification
• 24/7 emergency deployment support
Certifications
Explosion Protection
• China Ex
-Ex db IIC T6 Gb
•ATEX
-Ex tb IIIC T80C Db
-II 2G Ex db IIC T6 Gb
·SIL3
Safety Integrity Certification
-II 2D Ex tb IIIC T80C Db
AA6 Gas Alarm Controller AA6
Application Features
Multi-Point Smart Monitoring
• Up to 240 detectors, wide area coverage
• Multi-sensor support, complex scenarios
Industrial-Grade Reliability
• -20°C\~70°℃ wide temp, robust outdoors
• IP65 protection, dust & water proof, long life
Specification
Detector Capacity
Unit Types
240 Units
Maximum Range
%LEL; %LEL·m; %VOL; %VOL·m; ppm; ppm·m
Display Type
200%LEL; 100%VOL; 999,999ppm
Alarm Type
LCD Color Touch Screen
Input Channels
Audible and Visual Alarm
(Single Optional)
4-20mA | 16 Channels
RS485 Modbus RTU |1 Channel
Switch Output
LoRa Wireless | 1 Channel
Two-stage Alarm Relay | 2 Channels
Fault Relay | 1 Channel
Data Output
Shielding Relay | 1 Channel
4G Network Communication (Optional NB-IoT) , MQTT Protocol
10/100/1000M Ethernet TCP/IP, Modbus RTU Protocol
Relay Characteristics
• Contact Form
SPST-NO (Single Pole Single Throw, Normally Open) 5.0A @AC220V
• Contact Rated Load
Storage Specifications
•Storage Capacity
History Records >1,000,000
Alarm Data Records> 200,000
Power-off Records > 10,000
Operation Records > 10,000
Fault Records > 10,000
Shielding Records > 10,000
• Storage Method
SD Card (Removable)
Environmental Parameters
•Operating Temperature -20-70°C
• Storage Temperature -40-70℃
• Operating Humidity
≤98% RH
• Operating Air Pressure
80kPa-116kPa
Power Specifications
• Input Voltage
Main Power: 80 - 305 VAC, 50/60 Hz
Backup Power: 12V 4.5Ah Lead-Acid Battery, Runtime ≥2h
• Power Consumption
• Power Output
≤150W (Full Load)
Mechanical Construction
24VDC, 6A (Main Power Supply)
•Shell Material
Galvanized Steel Sheet
• Ingress Protection IP65
•Weight 5.0kg
Flexible Network & Cloud
• 4G/Ethernet, MQTT, data to cloud
• Optional LoRa, wireless deploy, cost-saving
Easy & Efficient Maintenance
• Color LCD, audio-visual alarms, fast response
• SD card log, data trace, easy analysis
Equipment Functions
Multi-channel Data Acquisition and Storage
Multiple Alarm Signal Outputs
Flexible Integration of Multi-type Detectors
Wireless Data Transmission Function
Intelligent Self-checking and Fault Diagnosis
Unified User Permission Management
Areas of Application
Smart Chemical Park Safety
• Plant area grid monitoring, production safety
• Corridors & warehouses, leak early warning
Municipal Gas Refined Mgmt
• Pipeline station monitoring, quick incident response
• Underground pipes, safety status alerts
Warehouse & Logistics Safety
• Hazardous storage monitoring, over-limit alarm
• Cold chain logistics, refrigerant leak detection
Environmental & Exhaust Monitoring
• Industrial exhaust, online continuous monitoring
• Air quality grid, pollution source tracking
Other Industrial Safety
• Spray/welding shops, gas safety monitoring
• Pharma/electronics, VOCs gas detection
Gas Alarm Controller A-711-B01
Compact Standalone Monitor - Efficient & Economical
• Designed for small, independent applications, supports 8-channel signal input.
• High cost-effectiveness meets budget-sensitive monitoring needs.
Intuitive Color Display & User-Friendly Operation
• 3.5-inch TFT color LCD clearly presents all 8-channel data.
• Audible and visual alarms activate simultaneously for prompt alerting.
Multi-Interface Compatibility & Flexible Configuration
• Supports 4-20 mA and RS485 Modbus RTU wired communica tion.
• Optional LoRa wireless for flexible site wiring
Reliable Performance & Traceable Safety
• Stores up to 4000 alarm and fault records for clear event tracking.
• Integrated backup power supports >2h outage monitoring.
Specification
Detector Capacity 8Unit
Unit Types %LEL; %LEL·m; %VOL; %VOL·m; ppm; ppm·m
Maximum Range 100%LEL; 100%VOL; 999,999ppm
Display Type 3.5-inch TFT Color LCD Screen
Audible and Visual Alarm
Input Channels
4-20mA|8 Channels
(Single Optional)
RS485 |1Channels
Switch Output
LoRa |1Channels
Alarm Relay | 2 Channels
Data Output
Fault Relay | 1 Channel
RS485 |1Channels(Default Modbus RTU protocol; supports wireless and protocol customization.)
Relay Characteristics Contact Form Contact Rated Load Storage Specifications Storage Capacity
SPST-NO (Single Pole Single Throw, Normally 5.0A @AC220V
Storage Method
Alarm Data Records>4,000 Fault Records >4,000 Internal Storage (Non-exportable)
Environmental Parameters
Operating Temperature -20-70℃
Storage Temperature -40-70℃
Operating Humidity≤98%
Operating Pressure 80kPa-116kPa
Power Specifications Input Voltage
80–305 VAC, 50/60 Hz/Main Power: 80–305 VAC
16.8V 3000mAh Lithium Battery, Runtime ≥ 2h
Power Consumption
≤50W (Full Load)
Power Output
Mechanical Construction
24VDC/2A (Main Power Supply)
Shell Material Galvanized Steel Sheet
Ingress Protection IP54
Weight 2.75kg
Equipment Functions
Multi-Channel Signal Acquisition & Display
Over-Limit Audio-Visual Alarms
Intelligent On-Site Data Logging
Supports Field-Triggered Outputs
Areas of Application
Small Industrial Plants
Independent Commercial & Industrial Sites
• Small boiler rooms, pump stations, independent gas storage facilities, laboratories
• Kitchen areas in small businesses and restaurants
Municipal Gas Local Management
Rapid Deployment Scenarios
• Suitable for small independent systems with a limited number of monitoring points
XB8 Laser Gas Remote Sensing Detector XB8
Application Features
Remote Detection
• Penetrates glass/flame via laser telemetry
• Industry-leading ppm sensitivity & detection limits
• IP65 housing & ergonomic design for harsh O&G sites
• 24/7 runtime with instant-charge docking
Industrial Reliability
Leak Localization
• Green laser guidance with real-time tracking
• Explosion-proof certified & precalibrated for safety
Specification
Sampling Method Open Path
Path Lengths 60m
Measuring Range 0-100,000 ppm·m
Accuracy True value ±20% @Standard reflective surface
Response Time (T90) <0.1s
Display Type Color LCD
Environmental Parameters
• Operating Temperature -10-50°C
• Storage Temperature -40-60℃
• Operating Humidity ≤98%
• Operating Pressure 80kPa-116kPa
Power Specifications
• Endurance Normal operation > 8H
Full load operation > 4H
(Continuous sound and light alarm)
• Charging Method Charging Dock
• Internal Battery Built-in Lithium Manganate Battery
Laser Safety Classification
• Detection Beam CLASSI
• Alignment Beam CLASS IIIR
Mechanical Construction
• Shell Material ABS+PC
• Ingress Protection IP65
•Weight 420g
Equipment Functions
Handheld Methane Leak Locator(Custom gases)
Real-time Leak Source Localization and Alarm
Tri-mode Alarms (Sound/Light/Vibration)
Areas of Application
Energy Infrastructure
• Remote leak screening for refinery pipelines/LNG tanks
• Real-time seal monitoring at wellheads
Urban Gas Systems
• Non-invasive leak detection in buried distribution networks
• Failure localization at gas pressure stations
Industrial Safety
• Pressurized leak source tracing in chemical plants
• Pre-entry hazard scanning for confined spaces
Certifications
Explosion Protection
• China Ex
-Ex ib IIC T4 Gb
•ATEX
-Ex II 2G Ex ib IIC T4 Gb
| Laser | CH4 | NH3 | C2H2 | Co | CO2 | HCL |
Portable Gas Detection
XD8 Laser Gas Remote Sensing Detector XD8
Application Features
Extremely Lightweight & Exceptional Value
• Ultra-compact, pocket-sized for easy carrying
• Cost-effective for universal personal safety wear
Integrated Light & Detection, Multi-Functional
• Built-in bright flashlight for cabinets, basements, and dark spaces
• Sliding cover toggles light/detection mode for efficient inspections
Dual-Power Convenience, Easy Charging
• Removable rechargeable battery eliminates power anxiety
• Integrated Type-C direct charging for flexible power needs
Precision Short-Range & Fast Response
• 15-meter detection range optimized for close-up inspection
• Tripod mount included for extended fixed-point monitoring
Specification
Sampling Method Open Path
Path Lengths 15m
Measuring Range 0-100,000 ppm·m
Accuracy ±20% @ Standard reflective surface
Response Time (T90) < 0.1s
Display Type Color LCD
Environmental Parameters
• Operating Temperature -10-50℃
• Storage Temperature -40-60℃
• Operating Humidity ≤98%
• Operating Pressure 80kPa-116kPa
Power Specifications
•Endurance
Normal operation>10h
Full-load operation>4h (with continuous
audible and visual alarm)
• Charging Method
Type-C direct charging
• Battery
Built-in Lithium Manganate Battery
Laser safety classification
• Detection Beam
CLASS I
• Alignment beam
CLASS IIIR
Mechanical Construction
• Shell material Aluminum alloy
• Ingress protection IP67
•Weight 200g
Equipment Functions
Non-Contact Laser Methane Leak Detection
Leak Source Location & Real Time Alarm
Tri-mode Alarms (Sound/Light/Vibration)
Dark Area Illumination
Removable & Replaceable Battery
Areas of Application
Residential Gas Safety Inspection
• Detection in confined dark spaces (cabinets, under stoves)
• Key point checks: gas meters, valves, hoses
Low-Light Environment Patrol
• Urban underground utility tunnels, deep pipeline & valve pits
• Unlit basements, corridors, and equipment room corners
End-Point Pipeline Screening
• Detection at hard-to-reach elevated & wall-mounted pipes
• Quick screening of regulators and valve pits in residential areas
Industrial & Commercial Confined Spaces
• Leak detection in cramped equipment layers & flange joints
• Inspection of hidden pipelines & dead corners in commercial kitchens
Certifications
Explosion Protection
• China Ex
•ATEX
-Ex ib IIC T4 Gb
-Ex II 2G Ex ia IIC T4 Ga
Open Path Gas Detection
BA8 Portable Gas Detector
BA8
Application Features
Cost Innovation Solutions
• Optimized laser detection with premium-grade performance
• TDLAS enables permanent calibration-free operation
Ultra-Portable Design
• Ergonomic structure for continuous wearable use
• Multi-scenario deployment via pocket/belt carry
Intrinsic Safety System
• Full-process Ex ib IIC T4 Gb certification
• False alarm immunity for vapor/chemical interference
Proactive Alert System
• Early-stage methane detection with pre-threshold alerts
• Tri-mode alarms (sound/light/vibration) trigger instant response
Specification
Sampling Method Passive Diffusion
Measuring Range 0-100 %LEL
Accuracy
0-60 %LEL:±3 % F·S
60-100 %LEL : ±5 % F·S
Resolution
1%LEL
Response Time (T90) ≤25s
Display Type
Segment FSTN
Environmental Parameters
• Operating Temperature
-25-55℃
• Storage Temperature
-40-60℃
• Operating Humidity
≤98%
• Operating Pressure
80kPa-116kPa
Power Specifications
• Endurance
≥10h
• Charging Method
Docking Charger | Cabinet Charger
• Internal Battery
Built-in Lithium Manganate Battery
Mechanical Construction
• Shell Material PC+TPE
• Ingress Protection IP65
• Weight 200g
Equipment Functions
Laser Methane Detection
Temperature and Pressure Detection
Tri-mode Alarms (Sound/Light/Vibration)
Auto-Logging Storage
Areas of Application
Industrial Safety Standard
• Cost-effective workforce-wide deployment
• All-day wearable for petrochemical/metallurgical processes
Confined Space Monitoring
• Real-time gas detection in underground utilities/tanks
• Dynamic inspection in WWTP restricted areas
Critical Operations
• Multi-point monitoring during equipment overhaul
• Instant data capture for process anomalies
Emergency Response
• Lightweight for multi-tool rescue coordination
• Explosion-proof reliability in extreme conditions
Certifications
Explosion Protection
• China Ex
•ATEX
-Ex ib IIC T4 Gb
Portable Multi - Gas Detector BB9
Application Features
Maintenance-Free Revolution
• TDLAS enables permanent calibration-free operation
• 10+ year core durability, zero consumables & sensor poisoning
Industrial-Grade Adaptability
• Reliable performance in H₂S/CO₂ environments
• IP65 rating with impact-resistant housing
• Micro-leak detection with interference immunity
Precision Across Scenarios
• Optional pump for directional sampling
• One-hand control with instant LCD feedback
• 10h continuous runtime via smart docking
Specification
Sampling Method Passive Diffusion/Active Sampling
Display Type Color LCD
Environmental Parameters
• Operating Temperature -25-55℃
• Storage Temperature -40-60℃
• Operating Humidity ≤98%
Uninterrupted Operation
• Operating Pressure 80kPa-116kPa
Power Specifications
• Endurance ≥10h
• Charging Method
Charging Dock
• Internal Battery
Built-in Lithium Manganate Battery
Mechanical Construction
• Shell Material ABS+PC
• Ingress Protection IP65
·Weight <330g
Equipment Functions
Laser Methane Detection
Electrochemical Carbon Monoxide Detection
Optional Pump Suction Sampling
Temperature and Air Pressure Display
Triple Warning (Beep/Flash/Buzz)
Areas of Application
Urban Gas Safety
Confined Space Protocol
Active Mining Monitoring
Storage & Transport Emergency
Certifications
Explosion Protection
• China Ex
•ATEX
Explosion Protection
-Ex ib I Mb
• China Mining Safety
-IM2 Ex ib IMb
-MA (Coal Mine)
| Part Number | GB992B97001 | GB811B08003 |
| Target Gas | CH4&CO | CH4 |
| Measuring Range | 0-10 %VOL (CH4) 0-1,000 ppm (CO) | 10-5,000ppm |
| Accuracy | 0.00-1.00 %VOL:±0.06 %VOL (CH4)1.0-10.0 %VOL: True value ±6% (CH4)0-100ppm : ±4ppm(CO)100-500ppm : True value ±5%(CO)500-1,000ppm : True value ±6%(CO) | 10-100ppm:±5ppm100-5,000ppm: True value ±5% |
| Resolution | 0.01%VOL (CH4) 1ppm (CO) | lppm |
| Response Time | <25s(CH4)<45s (CO) | <2s |
Protable Gas Detection
| Laser | CH4 | NH3 |
| Infrared | CO2 | |
| Electrochemistry | H2S | co |
Product Dimensions
\* Optional accessories are detailed on page 45,46.
Coal Mine Laser Gas Detector GJJ100B-INTL
Application Features
Safety Interlock Cutoff
• Auto-shutdown on gas overload prevents ignition risks
• SPDT-integrated system meets mining Ex-protected standards
• 304L Stainless Steel sealed construction (IP65 rated)
• LiMn₂O4 battery ensures 4-hour continuous monitoring
Industrial-Grade Architecture
Blackout Resilience
• Online auto-charging synchronizes with equipment power systems
• Compact design for confined space installations
Smart Connectivity
• RS485/CAN/4-20mA multi-interface support
• Real-time temp/pressure data enables smart ventilation or speed control
Specification
Sampling Method
Measuring Range
Passive Diffusion
Accuracy
0-100 %VOL
0.00-1.00 %VOL:±0.05 %VOL
1.0-100.0 %VOL : True value ±5%
Resolution
Response Time (T90)
0.01 %VOL
Display Type
Alarm Sound Level
≤25s
7-segment LED
Environmental Parameters
>80 dB @ 1m
• Operating Temperature
• Storage Temperature
0-40℃
• Operating Humidity
-40-60℃
• Operating Pressure
≤98%
Power Specifications
• Backup Power Runtime
80kPa-116kPa
• Charging Method
>4h
• Internal Battery
Online automatic charging
• Input Voltage
Built-in Lithium Manganate Battery
• Power Consumption
12-24VDC
<4.8W
Communication Specifications
• Communication Interface
RS485 (Default) (CAN / 4-20mA optional for
0-10%VOL range) / 200-1KHz output for
0-4%VOL range.
• Communication Protocol
Relay Characteristics
Modbus RTU
• Contact Form
• Power Cutoff Capability
SPDT
5A@DC30V 5A@AC250V
Mechanical Construction
10A @ AC125V
• Shell Material
• Ingress Protection
•Weight
304 Stainless Steel
IP65
2.0kg
Equipment Functions
Laser Methane Detection
Over-Limit Alarm and Power-off Control
Backup Power Operation
Areas of Application
Mining Equipment Safety
• CH4 monitoring & power interlock for shearers/roadheaders
• Haul truck/shuttle car operational safety
Smart Ventilation
• CH4-adaptive speed control for fan arrays
• Ventilation optimization in gas drainage
Critical Zone Monitoring
• Methane accumulation in sealed goafs/tunnels
• Explosive atmosphere monitoring for key facilities
Mine Modernization
• Gas protection retrofits for legacy equipment
• Smart safety networks deployment
Certifications
Explosion Protection
Functional Safety
• China Ex
• China Mining Safety
-Ex ib I Mb
-MA (Coal Mine) & KA (Non-coal Mine)
| Laser | CH4 | co | CO2 | H2S | C2H2 | O2 | HCL |
| Infrared | CO{2 | C3H8 | |||||
| Electrochemistry | co | O2 | H2 | HCL | |||
| Thermal catalysis |
Fixed Gas Detection
Mining Laser Methane Power Failure Device DJJ100/127-INTL CH4 Laser
Application Features
Highly Integrated, Ultra-Compact
• Built-in power cut-off and battery, smallest in its class
• Solves space constraints, easy to deploy
Laser Core, Accurate & Maintenance-Free
• TDLAS laser tech, millisecond response, shock-resistant
• High precision, no false alarms, 6-month calibration
Robust Structure, Durable
• Round stainless steel shell disperses impact force
• Explosion-proof IP68, withstands dust and water
Flexible Power, Wide Compatibility
• AC127V & DC24V versions fit various systems
• Wide voltage design, stable in fluctuating conditions
Specification
Sampling Method Passive Diffusion
Measuring Range 0-100 %VOL
Accuracy 0.00-1.00 %VOL:±0.05 %VOL
1.00-100.0 %VOL:Truth value±5%
Resolution 0.01 %VOL
Response Time (T90) ≤25s
Display Type 7-segment LED
Alarm Sound Level >80 dB @1m
Environmental Parameters
• Operating Temperature 0-40℃
• Storage Temperature -40-60℃
• Operating Humidity ≤98%
• Operating Pressure 80kPa-116kPa
Interference Immunity
• Electrical Fast Transient/Burst ±2kV Immunity
• Surge (Impulse) Immunity ±2kV
Power Specifications
• Backup Power Runtime >4h
• Charging Method
Online automatic charging
• Internal Battery
Built-in Lithium Manganate Battery
• Input Voltage
AC85\~265V / 12-24V
• Power Consumption
< 4.8W
Communication Specifications
• Communication Interface
RS485(Default) (CAN / 4-20mA optional
for 0-10%VOL range) / 200-1KHz output for
• Communication Protocol
0-4%VOL range
Relay Characteristics
Modbus RTU
• Contact Form
• Power Cutoff Capability
SPDT
1A @AC240V (Limit Value)
1A @AC125V
2A @DC120V (Limit Value)
2A @DC30V
Specification
Mechanical Construction
•Shell material 304 Stainless Steel
• Ingress protection IP68
• Weight 2.2kg
Equipment Functions
Onboard Methane Real-Time Monitoring
Exceed-Alarm and Power-Off Control
Backup Power Capability
Remote Parameter Setting via Controller
Areas of Application
Fully Mechanized Mining/Face
• Installed on shearers/roadheaders for mobile monitoring
Underground Auxiliary Transport
• Explosion-proof vehicles: trackless tires, personnel carriers
Continuous Mining Operations
• Continuous miners, shuttle cars under heavy vibration
Other Onboard Environments
• Points prone to impact: conveyor head, transfer machines
Certifications
Explosion Protection
• China Ex
Functional Safety
• China Mining Safety
-Ex mb [ib Mb]I Mb
Fixed Gas Detection
| Laser | CH4 | co | CO{2 | H2S | C2H2 | O2 | HCL |
| Infrared | CO2 | C3H8 | |||||
| Electrochemistry | co | O2 | H2 | HCL | |||
| Thermal catalysis |
Coal Mine Portable Laser Gas Detector BA8
Application Features
Cost Innovation Solutions
• Laser detection with price-optimized performance matching premium industry standards
• 6-month calibration breakthrough in coal mining (vs. 7-15 days standard)
Ultra-Portable Design
• Lightweight structure enables all-position wearable use
• Fuss-free deployment for multi-scenario carry (pocket/belt)
Intrinsic Safety System
• Full-process Ex ib I Mb certification for mobile inspections
• Mist/dust false alarm immunity through anti-interference algorithms
Proactive Alert System
• Early-stage methane detection with pre-threshold alerts
• Triple-mode (sound/light/vibration) alarms ensure instant on-site response
Specification
Sampling Method Passive Diffusion
Measuring Range 0-10 %VOL
Accuracy 0.00-1.00 %VOL:±0.06 %VOL
1.0-10.0 %VOL: True value ±6%
Resolution
0.01 %VOL
Response Time (T90) ≤25s
Display Type
Segment FSTN
Environmental Parameters
• Operating Temperature 0-40℃
• Storage Temperature
-40-60℃
• Operating Humidity
≤98%
• Operating Pressure
80kPa-116kPa
Power Specifications
· Endurance
≥10h
• Charging Method
Docking Charger | Cabinet Charger
• Internal Battery
Built-in Lithium Manganate Battery
Mechanical Construction
• Shell Material PC+TPE
• Ingress Protection IP65
·Weight 178g
Equipment Functions
Laser Methane Detection
Temperature and Air Pressure Display
Triple Warning (Beep/Flash/Buzz)
Auto-Logging Storage
Areas of Application
Universal Safety Gear
• Cost-effective deployment across workforce
• Unobtrusive wearing for full-process operations
Mobile Monitoring Grid
• Batch deployment creates gas concentration mapping
• Rapid checks at high-risk zones
Temporary Operations
• Multi-point monitoring during maintenance
• Dynamic data collection for ventilation tuning
Emergency Readiness
• Lightweight for multi-tool rescue operations
• Impact-resistant for disaster environments
Certifications
Explosion Protection
Functional Safety
• China Ex
• China Mining Safety
-Ex ib I Mb
-MA (Coal Mine)
•ATEX
-I M2 Ex ib I Mb
LaserCH4
Product Dimensions
Detector Intelligent Charging Cabinet CLF-50WG-INTL
Application Features
Intelligent Management, Cost & Efficiency
• Smart issue/return, cyclic use, no idle instruments
• Boosts efficiency, reduces manpower
Full-Process Data Traceability
• Logs instrument charging & personnel info, generates reports
• Issue, return, charging all traceable
Multi-Safety Protection, Unattended
• Real-time charging monitoring, over-current protection, fault alarm
• Supports unmanned operation, reliable operation
Digital Adaptability & System Integration
• Interfaces with digital mine platforms, open API
• Enables automated, info-based, intelligent equipment management
Equipment Functions
• High-Capacity Cluster Management
A single cabinet accommodates 50 detectors, supports wired/wireless
networking, and enables automated charging, dispatch, and return.
• Intelligent Fault Lockout
Automatically checks laser sensors, firmware, and battery status.
Locks faulty units to ensure only 100% compliant instruments are
• Multi-Level Safety Protection
Industrial-grade circuit design with short-circuit, over-current, and over-voltage protection. Real-time charging monitoring ensures safe operation.
• Convenient Operation & Management
Returned detectors can be plugged into any free slot (NFC auto-rec-
ognition). Iris + facial recognition enables fast, secure access.
• Granular Permission Control
Supports super/regular admin roles with clear permission levels,
ensuring assigned personnel responsibility.
• Full lifecycle Data Management
Automatically logs usage, issue, and return history. Supports Excel
import/export, print, and inspection-date alerts for ful traceability.
Specification
Single Cabinet Capacity 50 Units
Input Voltage AC220V
Input Current <4A (Per Cabinet)
Charging Protection Response Time 5ms
Charging Mode
The terminal charging management features
intelligent constant voltage and constant
current charging modes.
Unit Display Shows
Photo
Employee Information
Charging Power Level
Charging Voltage
Charging Current
Cabinet Door Status
External Dimensions
Instrument Charging Status, etc
• Per Cabinet External Dimensions
• Internal Cavity Dimensions
3100(Length)\*300(Width)\*2070(Height)mm
Environmental Parameters
300(Depth)\*240(Width)\*180(Height))mm
• Operating Temperature
• Operating Humidity
-5-40℃
• Storage Temperature
< 95%RH
• Storage Humidity
-20-60℃
Environmental Parameters
< 90%RH
•Weight
400kg
Coal Mine Portable Laser Gas Detector
BC8
Application Features
Dual-Laser Detection Technology
• Cross-interference-free simultaneous CH₄/CO₂ monitoring
• Enhanced molecular selectivity eliminates catalytic sensor false alarms
Full-Scenario Adaptation
• Ex-certified explosion-proof construction for hazardous zones
• 316L stainless steel core components resist coal dust and corrosion
Intelligent Support Systems
• Temperature-pressure compensation neutralizes environmental interference
• Real-time sensor health diagnostics with degradation alerts
Digital Inspection Integration
• RFID-enabled automated gas logging with inspection point geolocation
• Bluetooth/WiFi real-time data streaming to central monitoring systems
Specification
Sampling Method
Measuring Range
Passive Diffusion
0-10 %VOL
(Customizable 0-100%VOL) (CH₄)
0-5.00 %VOL (CO₂)
Accuracy
CH4
0.00-1.00 %VOL:±0.05%VOL
1.00-4.00 %VOL: ± 0.10%VOL
4.00-7.00%VOL: ± 0.20%VOL
7.00-10.0%VOL: ± 0.30%VOL
CO2
0.00-0.50%VOL: ± 0.10%VOL
0.50-5.00%VOL: ± (0.05+True value 5%)
Resolution
0.01 %VOL
Response Time (T90)
≤25s
Display Type
Monochrome OLED
Environmental Parameters
• Operating Temperature
0-40℃
• Storage Temperature
-40-60℃
• Operating Humidity
≤98%
• Operating Pressure
80kPa-116kPa
Power Specifications
• Endurance
≥10h
• Charging Method
Charging Dock
• Internal Battery
Built-in Lithium Manganate Battery
Mechanical Construction
• Shell Material
ABS+PC
• Ingress Protection
IP65
• Weight
423g
Equipment Functions
Laser Methane & Carbon Dioxide Detection
Temperature and Air Pressure Display
Bluetooth & WiFi Communication
RFID Inspection Check-in
Triple Warning (Beep/Flash/Buzz)
Areas of Application
Critical Zone Monitoring
• Dual-gas dynamics in working face apex zones
• Concurrent CO₂/CH4 monitoring in return airways
Sealed Space Safety
• Dual-risk control during goaf seal removal
• CH4-CO₂ interaction tracking in abandoned workings
Post-Disaster Evaluation
• Post-fire gas interference resolution
• Dual-gas compliance assessment in blast zones
Emergency Management
• Evacuation path gas matrix modeling
• Safety-tiered alternative route management
Certifications
Explosion Protection
• China Ex
Explosion Protection
-Ex ib I Mb
• China Mining Safety
-MA (Coal Mine)
Product Dimensions
Coal Mine Laser Methane Remote Sensing Detector xB8 CH4 Laser
Application Features
Non-Invasive Laser Sensing
• 0.5-30m open-path detection for goaf/blind lane monitoring
• Class IIIR green laser visualizes gas plumes in low-light conditions
Instant Response & Harsh Environment Resilience
• Subsecond T90 response time captures methane spikes
• IP65 rating with optical path compensation for high humidity /dust
Intrinsic Safety Design
• Ex ia I Ma certification for explosive methane atmospheres
• Ergonomic mobile configuration suits rescue operations
Dual-Mode Power Management
• Full load alarm>3 hours, automatic mode exceeds 5 hours, manual mode has longer battery life
• Dedicated charging dock for fast energy replenishment
Specification
Sampling Method Open Path
Path Lengths 30m
Measuring Range 30m
Measuring Range 0-100,000 ppm·m
Accuracy True value ±20% @Standard reflective surface
Response Time (T90) < 1s
Display Type Color LCD
Environmental Parameters
• Operating Temperature -10-50℃
• Storage Temperature -40-60℃
• Operating Humidity ≤98%
• Operating Pressure
80kPa-116kPa
Power Specifications
• Endurance
Automatic mode > 5h
Full load operation > 3h
(Continuous sound and light alarm)
• Charging Method
Charging Dock
• Internal Battery
Built-in Lithium Manganate Battery
Laser Safety Classification
• Detection Beam
CLASS I
• Alignment Beam
CLASS IIIR
• Ranging Beam CLASS II
Mechanical Construction
• Shell Material ABS+PC
• Ingress Protection IP65
·Weight 420g
Equipment Functions
Handheld Methane Leak Locator
Laser Ranging
Triple Warning (Beep/Flash/Buzz)
Areas of Application
Mining Face Gas Monitoring
• Real-time CH₄ fluctuation tracking at shearer drums/roadheader cutterheads
• Mobile inspection along conveyors/rail tracks to pinpoint gas leakage Sealed Zone Access Control
• Non-contact detection through cracks/vents in sealed roadway doors
• Pre-entry remote scanning for methane hotspots in abandoned faces
Ventilation System Validation
• CH4 gradient analysis across airlock doors/air crossings
• Multi-point laser scanning identifies stagnant gas zones
Post-Disaster Assessment
• Remote gas dispersion mapping after outbursts/explosions
• Dynamic concentration analysis for safe rescue route planning
Equipment Maintenance Safety
• Non-contact methane screening before live electrical maintenance
• Continuous monitoring during welding to prevent ignition
Certifications
Explosion Protection
Explosion Protection
• China Ex
• China Mining Safety
-Ex ia I Ma
•ATEX
-MA (Coal Mine)
-Ex I M2 Ex ia I Ma
Portable Gas Detection
| Laser | CH4 | NH3 | C2H2 | CO | CO2 | HCL | O2 |
Gas Sampling Pump
TX1000-INTL
Telescoping version
Portable Gas Detection
Specification
Sampling Pump Flow
>550mL/min
Environmental Parameters
• Operating Temperature
0-40°℃(Mining)
-10-40°℃(Industrial)
• Storage Temperature
-20-60℃
• Operating Humidity
≤98%
• Operating Pressure
80kPa-116kPa
Mechanical Construction
• Shell Material
• Weight
ABS
240g
Certifications
Explosion Protection
• China Ex
-Ex ib I Mb(Mining)
-Ex ib IIC T6 Gb(Industrial)
Product Dimensions
Gas Sampling Pump
TX1000-INTL |Wanxiang style
Portable Gas Detection
Specification
Sampling Pump Flow
Environmental Parameters
• Operating Temperature
• Storage Temperature
• Operating Humidity
• Operating Pressure
>550mL/min
• Shell Material
-20-60℃
Mechanical Construction
-10-40℃
≤98%
80kPa-116kPa
• Weight
ABS
240g
Certifications
Explosion Protection
• China Ex
-Ex ib IIC T6 Gb
Product Dimensions
Optical Reflector
TX3000-INTL
Open Path Gas Detection
Specification
Reflective surface material
Special PVC
Mechanical Construction
• Frame material
Aluminium Alloy
•Size
500mm\*500mm
•Weight
(1000mm\*1000mm Premium)
>2.1kg
Product Dimensions
Calibration Gas Box
TX4000-INTL
Open Path Gas Detection
Specification
Detect Gas
measurement range
power supply voltage
Mechanical Construction
5VDC
• Shell material
•Weight
Methane (customizable for other gases)
5 kg
0-99999ppm·m (other ranges can be customized)
Acrylic, Quartz
Product Dimensions