dooch
Hotwater circulation pump DPC Series
User'smanual
Safety precaution
Prior to installationand use,please read thismanual for yourunderstanding. Please place this manual where anybody can find easily. This manual contains warranty certificate.
Preface
Thank you for choosing our products.
Thismanual contains the instructions for operation and caution foruse.
Please read and understand thismanual carefully for its best performance.
Theproduct should be used according to the instructions on this manual only.
For any question,you can contact the distributor or supplier forthis product.
※Any contenton thismanual canbe changedwithoutanynotice, duetoproductperformanceenhancementortechnicalmatter.
Available forhigh temperature( - 1 0 ^ { \circ } C - + 1 1 0 ^ { \circ } C ) (20号
Available for hight pressure (Max.10bar)
Y1 EASY
Compact design,easy to install
Low noise
国
3-speed control (Not applicable for DPC 50 series)
Purpose
Hotwatercirculation Industrial, Closed circulationsystem
Caution for use and handling
A
Caution
Inordertoavoid electric shock,please installthecircuitbreak ratedunder \mathsf { 3 0 m A }
A
Caution
Inordertoavoidelectric shock,please switch OFFwhen you install, uninstall orcarry out the maintenance forpower supply.
A
Caution
In order to avoid electricshock dueto anybadinsulation, pleaseapplytheearth grounding.
A
Danger
Do not touch the power cablewithwet handsto avoid electric shock,and keep the power cable not to be wet.
A
Caution
A
Caution
Keep the product from external impact,since it can causeanydamage.
Keep the product from external impactand humidity,inambient temperature of - 1 0 ^ { \circ } { C } ~ 5 0 { ^ \circ C } ,since it contains electric parts.
Donot install the product as the motor towards to vertical way.
A Caution
If youapply the product to boilers (with oil,briquette or charcoal),you have to build thepiping linesas [Fig.1].Especially,for the case of boilers runby briquette orcharcoal, you should not install the pump in front of fuel intake.
(※You should install the pump at side/backward of fuel intake.)
※This product is under guaranteeat the temperature up to 1 1 0 ^ { \circ } 0 only,this product is not responsible for them.
This product is for whom capable to handle with safety, only.
Please keep this product from children in order for them not to play with this.
In case the power cable is damaged,only theauthorized one oragent should
change that inordertoavoidanyaccident likeelectricshock.
A Caution
As[Fig.2],you canassemble the casing regardless itsdirection.You can change the casing direction according to following procedure.
1) Dis-assemble the casing bolts. (Make sure the boltsnot to be lost.)
2) Rotate the casing. (You can rotate the casing to 4 directions as the figure below.)
3)Re-assemble thecasingbolts.
Caution foruse
A
A
Danger
Do not cover the pump with cloth,vinyl or rag. It cancausefireaccident.
Caution
Do not carry the pumpas hangedby itspower cable.Any damagedue to this can cause electric leakage orshock.
A
Caution
Never run the pump dry. Anydamagecan be occurred for internal partsdue to that,and it can cause anyproblem.
A
Danger
This product should be usedonlyforcleanwater. Foranyother flammable mediaorchemicals, itwill cause fireaccident orany problem on pump.
When you dis-assemble the drain plug,you can be burnt by boiled water from the pump inside.So,during that,make sure for wearing suitable protection equipments, andavoidyourfacefrommotorside. Please becareful foranyaccident due to steam.Anysteam can be leaked from drainplug if itis loosenbyhightemperatureandsystempressure. In case any air remains in the pump or piping lines,water circulation could not be fluent.For that situation,loosen the drain plug with screw driver,and vent the aircompletely. ●During summer season,water scale can exist in the pump,if it is not under operation for long time.In that situation,the pump might not be operated even though power is supplied.
Components
How to control the pump speed
①De-energize the power supply.
{ x } With the speed control switch,you can adjust the motor R.P.M.in3 steps,according to operation condition.
③You cansave the Max. 50 % of energy, if you set the most suitable R.P.M.
\bullet In case the water heating is not done enough, the pump speed could be slow.For this case, speed up the pump.On the other hand, in case the pump speedis too high,any noise can be occurred from thermostatic regulating valve or piping lines.For this case,adjust the speed control switch for slow-down.
\otimes You can adjust the pump speed in 3 steps with the knob on terminal box,as [Fig. 4].
| Troubles | Cause | Counteraction |
| Pump is not operated. | Motorstuck due to non-operation | ★Rotate the shaft to clockwise. |
| Incorrect contact of power supply | ★ Check the contact of power supply. | |
| Defect on power cable | Replace the power cable. | |
| Defect on motor | Repair the motor. | |
| Low voltage | Check the voltage.In case the power supply is not enough against the voltage,discuss with power stationand make it higher | |
| Leakage from pump | Leakage from packing | ★Check the connection bolts |
| No water circulation whilst pump operation | No water in piping lines | ★Fill up the water in piping lines. |
| Air in piping lines | ★Eliminate the air from piping lines. | |
| Air ingress from suction piping line | ★Check and repair the piping lines or connections which are suspected for air ingress. | |
| Lowwatercirculation whilst pump operation | Valve closed | ★ Open the valve. |
| Strainer jammed | ★ Clean the strainer. | |
| Not enough pump capacity | ★Additional pump installation or change of pump to higher capacity ones. | |
| Air in piping lines | ★Eliminate the air from piping lines. |
DOOCH guarantee the quality of the product authorized and passed all the required QC procedure.Warranty periods and warranty services are varied in accordance with theregionwhere the customers purchase our product.Thewarranty period applies from thedateof purchaseby the first customerand is transferableonly between endusers.Thewarrantycoversmanufacturingdefectsonly.
| Product | Hot water circulation pump | Warranty | 1year |
| Model | DPC- | Purchased | |
| Agent | Validuntil | ||
| Address | TEL. |
Warranty policy
1.This product is under warranty for1year from purchased date. Please contact to our A/S centre oragent forany trouble.
2.This product will not be under responsibility of warranty for following cases.
- Trouble due to user's misuse (Not operating by manual instruction.)
-Trouble due to unauthorized repair,modification or dis-assemble.
-Force majeure
-Trouble due to improper storage.(High temperature/humidity, place with chemicals) - In case this warranty certificate is lost.
-Incaseanywarranty information is corrected.
- Parts or consumables are not under warranty.
-The product is not under responsibility for any consequential damage
from product trouble.
Notice
1.This certificate is for the warranty according to above policy,
not for the restriction foruser's legal right.
2.Forany question on this certificate,please contact our A/S centre or agent.
3.Please get this certificate filledwithwarranty information.
4.Please keep this certificate carefully,since this cannot be re-issued.
DOOCH CO.,LTD.
2F\~4F,162LS-ro,Gunpo-si,Gyeonggi-do,Korea TEL:+82-31-831-1243FAX:+82-31-831-1250 Web:www.doochpump.com
DPC(E)-1901-M