Dry-type Transformer
High Reliability
Maintenance Free
Electrical Sector
Power distribution and circuit
protection
Power quality, backup power
and power storage
Safety and security
Structural solutions
Control and automation
Solutions for harsh and
hazardous environments
Industrial Sector
Aerospace
Filtration
Vehicle
eMobility vehicle
electrification
Eaton's vision is to improve
quality of life and the
environment through the
use of power management
technologies and services.
• We are dedicated to developing
our employees by helping them
succeed not just at work, but in
life as well.
• We delight our customers by
understanding their challenges
and proactively delivering real
solutions.
• We deliver for our shareholders
by doing what’s right, so
investors want to own more
shares in our company.
• We support our communities by
providing products and solutions
that can improve quality of
life and the environment; we
also offer our time, talent and
resources to satisfy social and
economic needs where we work
and live.
2022 SALES
$ 6.4
BILLION
2022 SALES
$ 14.3
BILLION
Overview
Eaton
Eaton is an intelligent power management company dedicated to improving the
quality of life and protecting the environment for people everywhere. We are guided
by our commitment to do business right, to operate sustainably and to help our
customers manage power - today and well into the future. By capitalizing on the
global growth trends of electrification and digitalization, we’re accelerating the
planet’s transition to renewable energy, helping to solve the world’s most urgent
power management challenges, and doing what’s best for our stakeholders and all of
society.
Eaton was founded in 1911 and has been listed on the New York Stock Exchange
since 1923. We reported revenues of $20.8 billion in 2022 and serve customers in
more than 170 countries. Eaton entered the Chinese market in 1993 and has grown
significantly since then. In 2004, Eaton moved its Asia-Pacific headquarters from Hong
Kong to Shanghai. Today, Eaton has nearly 9,000 employees and 20 manufacturing
facilities in China. Eaton is marking its 100th anniversary of being listed on the New
York Stock Exchange, and its 30th anniversary of being in Chinese market.
NET INCOME
SALES
EARNING PER SHAREBILLION BILLION PER SHARE
$ 2.5
$ 20.8
$ 6.14
2
Overview 目录
FACILITIES
DATA CENTER
INDUSTRY
INFRASTRUCTURE
MACHINERY OEM
ALTERNATIVE ENERGY
Eaton’s Electrical Sector provides customized
comprehensive services by:
• Providing data centers with efficient and
safe energy-saving solutions to protect your
information and data.
• Providing photovoltaic, wind power, and hybrid
solutions to help you convert new energy into daily
power.
• Improving the reliability and uninterrupted running
time of smart grids.
• Providing continuous, clean, reliable power and
life cycle management services to improve project
efficiency.
• Helping enterprises to reduce operating costs
and complexity, enhancing the predictability of
operational failures, and ensuring personnel
safety.
• Assisting production equipment manufacturers
in making machinery production management
simpler,more reliable, safer, and more
energy-efficient
Focused and professional
3
Wisconsin, US
Texas, US
COOPER POWER SERIES
Transformers Haian, China
Eaton Transformer Jiangsu
Eaton Global Transformer Factories
Ankara, Turkey
Eaton Dry-type Transformer
A legacy of classics with rapid response to customer demands
Eaton transformer technology can be traced back to 1892
in which the first dry type transformer was developed.
In 1892
Eaton is committed to innovating and iterating transformers.
The acquisition of Cooper makes Eaton one of the world's
leading manufacturers of electrical equipment.
For over a century
In 2012
In 2023
Established in 2023
Eaton Transformer Jiangsu
Key products: Dry type transformer, Oil immersed
transformer, Prefabricated substation, Integrated
power conversion and step-up unit
Overview
Full series of Eaton
transformer solutions
• Complying with GB, IEC and UL standards
• Hundred years of technology heritage
• Customized manufacturing capabilities
• Rapid response to customer demands
4
Contents 目录
Dry-type Transformer
Product Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
Manufacturing. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Key Components. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Production Process. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Optional Accessories. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Quality Control. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Product Report. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Product Electrification Criteria. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 12
Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Key Markets. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
CONTENTS
5
Cast Resin Dry-type Transformer
Product Characteristics
Scope
Key components
• Voltage: Up to 35kV
• Rating : Up to 31.5MVA
• BIL : Up to 200kV
f. Insulation cylinder
e. Core
Core sheet metal consist of low loss, cold
rolled grain-oriented silicone sheets with
extruded cores
Reinforce insulation, improve the heat
dissipation of transformer
(between the LV coil and HV coil)
Standard arrangement: top
Customization: bottom
(on the behind)
Made of steel plate and processed
by laser cutting machine with high
accuracy. Rollers can spin both
horizontally and vertically
a. LV terminals
d. Clamping frame and truck
Safety
Safe, Non-flammable and self-extinguished
High efficiency
Low loss, low partial discharge, low noise and good
heat dissipation
Low cost
Maintenance free, easy to be settled and low
operation cost
Stability
Strong mechanical strength and short circuit withstand
Convenience
Moisture resistant, and can operate in 100%
humidity
Innovation
World’s leading three phase integrated 110kV cast
resin dry-type transformer
Environment-friendly
100% dry structure guarantees zero environmental
pollution
Climate-resistance
Working well even in extreme weather condition
a
e
f
g
h
b
C
d
Optimal layout schemes to adapt for various
substations. HV tapping link can adjust itself
to system voltage when power off
c. HV terminals
b. Coil support system
To isolate core and winding from
mechanical vibrations, reduce noise
emission
h. Low Voltage Coil
Belt(foil)winding conductors are used in
low voltage windings. F class(H class optional)
insulation material is saturated in the resin and
finally coils are hardened after winding process
g. High Voltage Coil
High voltage coils are using copper and
aluminum flat, round or band conductors
covered with F class (H class optional) glass
fiber. Windings are poured under vacuum
using premium resin
6
Manufacturing
Key Components
Core
The core material is made of high-quality cold-rolled grain-oriented silicon steel sheet
(amorphous alloy core uses amorphous alloy material). The core adopts 45º fully oblique
seam step-by-step lamination technology, the core-through screw pull plate structure, and
the automatic stacking robot technology of silicon steel sheets to ensure the size alignment of
the entire stack of silicon steel sheets and the lapping accuracy between sheets. High-quality
materials and complete technology can effectively reduce the no-load loss and noise level. The
outer surface of the core is coated with F-grade or H-grade black elastic two-component resin
paint, which can effectively prevent dust and rust.
HV winding
The HV winding adopts a cylindrical structure wound
continuously with insulated copper wire and double-layer
insulation. Under the vacuum state, the high-grade imported
epoxy resin is used for overall high-temperature curing and
molding. The mechanical strength after curing is very high, and
the ultimate surface tensile stress can reach the strength of
steel. The surface and air passage are very smooth, and it is
difficult for dust to adhere to the coil surface.
LV winding
The LV winding is made of a whole piece of round-edged
copper foil. The interlayer is insulated with thermosetting
epoxy prepreg cloth, which is cured at high temperature in
a curing furnace. There is no helix angle at the end of the
low-voltage foil winding coil, and the ampere-turn can be
automatically balanced in the axial direction according to the
distribution of the high-voltage coil, so that the short-circuit
electromotive force can be reduced to a minimum in the case
of a serious external short-circuit fault.
7
LV foil winding machine
The LV coil can be wound with electromagnetic wire, and Eaton
also produces LV transformers with foil coils, which have the
advantages of uniform electric field distribution and strong
short-circuit resistance. LV foil coils are tightly wound with highpurity round-edged foil tape and insulation pre-impregnated
with epoxy resin. The LV foil winding machine has the functions
of constant tension, deburring, and automatic deviation
correction.
Resin vacuum casting system
After the finished coil is pre-dried, it is transferred to the pouring
cabin of the epoxy resin vacuum casting equipment for vacuum
drying to remove moisture and gas in the insulation. At the same
time, materials such as epoxy resin and hardener are continuously
degassed in an independent material preparation tank. After the
processing process, the computer injects various chemical materials
into the mold according to the set ratio through the precision
metering system. After pouring, it is cured at high temperature in an
oven, and finally made into a strong solid coil.
Manufacturing
Production Process
Core automatic stacking equipment
The core is one of the key components of the transformer.
Eaton adopts first-class equipment, advanced technology, and
high-quality materials to ensure the quality of the core, which
greatly reduces the no-load loss and noise of transformers.
HV automatic winding machine
The HV coil automatic winding machine is controlled by a computer
program and has the functions of constant tension and automatic
winding. The HV coil is made of copper magnet wire, wound
together with insulating materials such as glass fiber, and adopts
a segmented cylindrical structure with low interlayer voltage and
strong overvoltage resistance. Larger capacity coils are equipped
with heat dissipation air passages, which have good heat dissipation
performance.
8
Optional Accessories
Optional Accessories
Cooling Fan
The transformer can be cooled by two modes: air natural cooling
(AN) and air forced cooling (AF). Forced-air AF output of the
transformer is up to 140% of the self-cooled rating, should be
used only for emergency non-recurring loads, and but is not
recommended for long-term running.
Steel-plate enclosure
The steel-plate enclosure is made of high-quality cold-rolled
steel plate, which is processed by CNC shearing machine,
CNC punching machine, and CNC plate bending machine. The
steel plate shell has the advantages of beautiful and exquisite
appearance, good ventilation performance, simple and quick
installation, and convenient transportation. The color of the steel
plate shell is RAL7032 computer gray or customized according to
user requirements.
Temperature Controller
The temperature is controlled by means of sensor provided
on each transformer. The sensor (PT100) is installed in the LV
winding. The digital controller shows the operating temperature
of each LV winding, sequentially. The temperature controller
performs the following functions of three-phase winding during
transformer running: automatically switch the cooling fans on at
100℃ and off at 80℃, it will send an over-temperature alarm at
130℃ , and will send emergency shutdown trip signal at 150℃
and sensor fault alarm.
Stainless steel enclosure
Stainless steel enclosure, the main material is stainless steel plate,
which is beautiful and anti-corrosion, and can be easily assembled
on site, with inspection doors on the front and back. The shell
protection device provides a safety barrier for the live parts, and
the protection level reaches IP20, IP23 and above. The IP20 casing
can prevent the entry of solid foreign objects with a diameter
greater than 12mm; the IP23 casing can also prevent the inflow of
water droplets within 60º from the vertical line.
9
干式变压器 Quality Control
Quality Control
Eaton quality control was carried out according
to ISO9001 quality management standard and
production standard, there are many quality
engineers working for IQC, PQC, FQC and OQC. All
transformers should be inspected and tested by
operator, auditor and inspector according to the
production standards and requirements before it
been transported to the next production process,
the failed product will be rejected. The product's
quality and reliability are ensured by our strict
management procedure, serious working attitude
and advanced testing equipments.
Transformer Inspection and Test Center
Test Item Test Type Test Item Test Type
Winding resistance measurements Routine test Induced-voltage test Routine test
Ratio and phase-relation tests Routine test Partial discharge measurements Routine test
No-load loss and excitation current
measurements Routine test Sound level measurements Type test
Load loss and impedance measurements Routine test Lightning impulse test Type test
Insulation resistance measurements Routine test Temperature rise test Type test
Applied-voltage test Routine test Short-circuit withstand test Special test
Impulse Test System Insulation ratio DC resistance test equipment Partial discharge laboratory
10
Product Report
Type Test Reports
SCB18-2500/10-NX1
SCB14-2000/10-NX2 SCB14-500/10-NX2
SCB18-1000/10-NX1
11
Product Electrification Criteria
10kV Class 100~3500kVA Distribution Transformer(Copper Winding)
Rated
Power
(KVA)
No-load
Loss
(kW)
On-load
Loss 120℃
(kW)
Short
Circuit
Impedance
(%)
Noise
(Lm-1)
(dB)
No-load
Current
(%)
Base Frame
Q1XQ2
(mm)
Weight
(kg)
Outline Dimension
(LengthxWidthxHeight)
(mm)
Enclosure Dimension
(IP20/IP21)
(LengthxWidthxHeight)
(mm)
100 0.40 1.57
4
47 1.5 550×660 640 1020×760×920 1600×1200×1400
125 0.47 1.85 48 1.3 550×660 700 1100×760×960 1600×1200×1400
160 0.54 2.13 49 1.3 660×660 860 1160×760×1000 1600×1200×1400
200 0.62 2.53 50 1.1 660×660 950 1200×760×1080 1600×1200×1400
250 0.72 2.76 50 1.1 660×660 1120 1240×760×1060 1600×1300×1500
315 0.88 3.47 50 1 660×660 1320 1300×760×1060 1600×1300×1500
400 0.98 3.99 50 1 660×660 1450 1400×760×1080 1800×1400×1600
500 1.16 4.88 50 1 660×660 1690 1480×760×1100 1800×1400×1600
630 1.34 5.88 50 0.85 660×660 2100 1500×760×1240 1800×1400×1600
630 1.30 5.96
6
50 0.85 660×660 1920 1580×760×1080 2000×1400×1800
800 1.52 6.96 51 0.6 820×820 2420 1680×920×1260 2000×1400×1800
1000 1.77 8.13 52 0.6 820×820 2760 1720×920×1340 2100×1400×1800
1250 2.09 9.69 54 0.5 820×820 3180 1780×920×1400 2100×1400×1800
1600 2.45 11.73 54 0.5 820×820 3960 1940×920×1420 2300×1500×2000
2000 3.05 14.45 56 0.5 1070×1070 4880 2000×1150×1580 2300×1500×2000
2500 3.6 17.17 60 0.5 1070×1070 5800 2120×1150×1680 2500×1600×2000
2000 3.05 15.96
8
56 0.5 1070×1070 4950 1930×1150×1630 2300×1500×2000
2500 3.6 18.89 60 0.5 1070×1070 5930 2080×1150×1780 2500×1600×2200
3150 4.28 22.46 62 0.5 1070×1070 7220 2180×1150×1840 2500×1600×2200
3500 4.63 24.31 64 0.5 1070×1070 8040 2250×1150×1900 2600×1600×2200
Remark: Eaton reserves the right to make changes or modify the contents of this catalogue without prior notice.
Eaton CRT can be designed and manufactured as per GB/IEC/ANSI standards.
HV Voltage:6kV/6.3kV/6.6 kV /10kV/10.5kV/11kV
LV Voltage:400V/415V/420V/433V
Frequency:50Hz/60Hz
HV tapping:±2*2.5%/±5%
Vector group:Dyn11/Dyn5/Dyn1/Yyn0
Material of winding:Copper
12
Product Electrification Criteria
10kV Class 100~3500kVA Distribution Transformer(Aluminum Winding)
Rated
Power
(KVA)
No-load
Loss
(kW)
On-load
Loss 120℃
(kW)
Short
Circuit
Impedance
(%)
Noise
(Lm-1)
(dB)
No-load
Current
(%)
Base Frame
Q1XQ2
(mm)
Weight
(kg)
Outline Dimension
(LengthxWidthxHeight)
(mm)
Enclosure Dimension
(IP20/IP21)
(LengthxWidthxHeight)
(mm)
100 0.40 1.57
4
47 1.5 550×660 580 1100×760×1040 1600×1200×1400
125 0.47 1.85 48 1.3 550×660 620 1180×760×1060 1600×1200×1400
160 0.54 2.13 49 1.3 660×660 790 1240×760×1100 1600×1200×1400
200 0.62 2.53 50 1.1 660×660 870 1280×760×1180 1600×1200×1400
250 0.72 2.76 50 1.1 660×660 1030 1320×760×1160 1700×1300×1600
315 0.88 3.47 50 1 660×660 1210 1340×760×1180 1700×1300×1600
400 0.98 3.99 50 1 660×660 1350 1420×760×1280 1800×1400×1700
500 1.16 4.88 50 1 660×660 1580 1500×760×1300 1800×1400×1700
630 1.34 5.88 50 0.85 660×60 1980 1530×760×1440 1800×1400×1700
630 1.30 5.96
6
50 0.85 660×660 1890 1600×760×1380 2000×1400×1800
800 1.52 6.96 51 0.6 820×820 2230 1720×920×1560 2000×1400×1800
1000 1.77 8.13 52 0.6 820×820 2560 1740×920×1640 2100×1400×2000
1250 2.09 9.69 54 0.5 820×820 2980 1810×920×1720 2100×1400×2000
1600 2.45 11.73 54 0.5 820×820 3760 1920×920×1720 2300×1500×2000
2000 3.05 14.45 56 0.5 1070×1070 4580 2020×1150×1760 2300×1500×2000
2500 3.6 17.17 60 0.5 1070×1070 5560 2080×1150×1980 2500×1600×2300
2000 3.05 15.96
8
56 0.5 1070×1070 4750 1920×1150×1960 2300×1500×2300
2500 3.6 18.89 60 0.5 1070×1070 5790 2080×1150×2020 2500×1600×2300
3150 4.28 22.46 62 0.5 1070×1070 6820 2180×1150×2080 2500×1600×2300
3500 4.63 24.31 64 0.5 1070×1070 7350 2250×1150×2150 2500×1600×2400
Remark: Eaton reserves the right to make changes or modify the contents of this catalogue without prior notice.
Eaton CRT can be designed and manufactured as per GB/IEC/ANSI standards.
HV Voltage:6kV/6.3kV/6.6kV/10kV/10.5kV/11kV
LV Voltage:400V/415V/420V/433V
Frequency:50Hz/60Hz
HV tapping:±2*2.5%/±5%
Vector group:Dyn11/Dyn5/Dyn1/Yyn0
Material of winding:Aluminum
13
Product Electrification Criteria
20kV Class 200~3500kVA Distribution Transformer(Copper Winding)
Rated
Power
(KVA)
No-load
Loss
(kW)
On-load
Loss 120℃
(kW)
Short
Circuit
Impedance
(%)
Noise
(Lm-1)
(dB)
No-load
Current
(%)
Base Frame
Q1XQ2
(mm)
Weight
(kg)
Outline Dimension
(LengthxWidthxHeight)
(mm)
Enclosure Dimension
(IP20/IP21)
(LengthxWidthxHeight)
(mm)
200 0.73 2.94
6
50 1.1 660×660 1370 1380×760×1220 2000×1500×2000
250 0.84 3.42 50 1.1 660×660 1380 1400×760×1230 2000×1500×2000
315 0.97 4.08 50 1 660×660 1480 1430×760×1295 2000×1500×2000
400 1.15 4.84 50 1 660×660 1660 1480×760×1355 2000×1500×2000
500 1.35 5.79 50 1 660×660 1820 1490×760×1405 2000×1500×2000
630 1.53 6.84 50 0.85 660×660 2030 1540×760×1430 2000×1500×2200
800 1.75 8.26 51 0.6 820×820 2380 1590×920×1550 2000×1500×2200
1000 2.07 9.78 52 0.6 820×820 2740 1620×920×1570 2200×1650×2200
1250 2.38 11.5 54 0.5 820×820 3330 1710×920×1615 2200×1650×2200
1600 2.79 13.8 54 0.5 820×820 4070 1810×920×1680 2200×1650×2200
2000 3.24 16.3 56 0.5 1070×1070 5130 1940×1150×1765 2500×1800×2400
2500 3.87 19.3 60 0.5 1070×1070 6070 2030×1150×1885 2500×1800×2400
2000 3.24 17.8
8
56 0.5 1070×1070 5200 2000×1150×1795 2600×1800×2400
2500 3.87 21.2 60 0.5 1070×1070 6200 2100×1150×1935 2800×1800×2500
3150 4.6 25.2 62 0.5 1070×1070 7380 2200×1150×1980 2900×1900×2600
3500 4.98 27.2 64 0.5 1070×1070 7990 2290×1150×2050 2900×1900×2600
HV Voltage:20kV/22kV/24kV
LV Voltage:400V/415V/420V/433V
Frequency:50Hz/60Hz
HV tapping:±2*2.5%/±5%
Vector group:Dyn11/Dyn5/Dyn1/Yyn0
Material of winding:Copper
Remark: Eaton reserves the right to make changes or modify the contents of this catalogue without prior notice.
Eaton CRT can be designed and manufactured as per GB/IEC/ANSI standards.
14
Product Electrification Criteria
20kV Class 200~2500kVA Distribution Transformer(Aluminum Winding)
Rated
Power
(KVA)
No-load
Loss
(kW)
On-load
Loss 120℃
(kW)
Short
Circuit
Impedance
(%)
Noise
(Lm-1)
(dB)
No-load
Current
(%)
Base Frame
Q1XQ2
(mm)
Weight
(kg)
Outline Dimension
(LengthxWidthxHeight)
(mm)
Enclosure Dimension
(IP20/IP21)
(LengthxWidthxHeight)
(mm)
200 0.73 2.94
6
50 1.1 660×660 1210 1450×760×1340 2000×1500×2000
250 0.84 3.42 50 1.1 660×660 1250 1420×760×1340 2000×1500×2000
315 0.97 4.08 50 1 660×660 1310 1440×760×1395 2000×1500×2000
400 1.15 4.84 50 1 660×660 1470 1490×760×1470 2000×1500×2000
500 1.35 5.79 50 1 660×660 1640 1530×760×1480 2000×1500×2000
630 1.53 6.84 50 0.85 660×660 1890 1580×760×1525 2000×1500×2200
800 1.75 8.26 51 0.6 820×820 2170 1630×920×1570 2000×1500×2200
1000 2.07 9.78 52 0.6 820×820 2680 1720×920×1640 2200×1650×2200
1250 2.38 11.5 54 0.5 820×820 3040 1810×920×1735 2200×1650×2200
1600 2.79 13.8 54 0.5 820×820 3810 1870×920×1955 2200×1650×2200
2000 3.24 16.3 56 0.5 1070×1070 4440 2000×1150×2045 2500×1800×2400
2500 3.87 19.3 60 0.5 1070×1070 5510 2190×1150×2075 2500×1800×2400
2000 3.24 17.8
8
56 0.5 1070×1070 4600 2050×1150×2100 2500×1800×2400
2500 3.87 21.2 60 0.5 1070×1070 5730 2240×1220×2130 2800×1800×2500
3150 4.6 25.2 62 0.5 1070×1070 6810 2320×1250×2180 2900×1900×2600
3500 4.98 27.2 64 0.5 1070×1070 7360 2400×1280×2250 2900×1900×2600
HV Voltage:20kV/22kV/24kV
LV Voltage:400V/415V/420V/433V
Frequency:50Hz/60Hz
HV tapping:±2*2.5%/±5%
Vector group:Dyn11/Dyn5/Dyn1/Yyn0
Material of winding:Aluminum
Remark: Eaton reserves the right to make changes or modify the contents of this catalogue without prior notice.
Eaton CRT can be designed and manufactured as per GB/IEC/ANSI standards.
15
Product Electrification Criteria
35kV Class 200~3500kVA Distribution Transformer(Copper Winding)
35kV Class 200~3500kVA Distribution Transformer(Aluminum Winding)
Rated
Power
(KVA)
No-load
Loss
(kW)
On-load
Loss 120℃
(kW)
Short
Circuit
Impedance
(%)
Noise
(Lm-1)
(dB)
No-load
Current
(%)
Base Frame
Q1XQ2
(mm)
Weight
(kg)
Outline Dimension
(LengthxWidthxHeight)
(mm)
Enclosure Dimension
(IP20/IP21)
(LengthxWidthxHeight)
(mm)
200 0.88 3.32
6
50 1.1 660×660 1480 1520×760×1680 2300×1800×2200
250 0.99 3.80 50 1.1 660×660 1760 1580×760×1740 2300×1800×2200
315 1.17 4.51 50 1 820×820 1980 1680×920×1660 2300×1800×2200
400 1.37 5.41 50 1 820×820 2280 1760×920×1700 2500×1800×2200
500 1.62 6.65 50 1 820×820 2480 1800×920×1720 2500×1800×2200
630 1.86 7.69 50 0.85 820×820 2900 1880×920×1800 2500×1800×2200
800 2.16 9.12 52 0.6 820×820 3380 1920×920×1900 2600×2000×2400
1000 2.43 10.40 52 0.6 820×820 3680 1980×920×1920 2600×2000×2400
1250 2.83 12.70 54 0.5 820×820 4280 2040×920×1960 2700×2000×2400
1600 3.24 15.40 56 0.5 1070×1070 5230 2120×1150×2040 2700×2000×2400
2000 3.82 18.20 58 0.5 1070×1070 5980 2240×1150×2080 2900×2200×2600
2500 4.45 21.80 60 0.5 1070×1070 6640 2300×1150×2200 2900×2200×2600
3150 5.29 28.50
8
64 0.5 1070×1070 8070 2400×1250×2300 3200×2300×2700
3500 5.72 30.80 68 0.5 1070×1070 8730 2480×1280×2380 3200×2300×2700
Rated
Power
(KVA)
No-load
Loss
(kW)
On-load
Loss 120℃
(kW)
Short
Circuit
Impedance
(%)
Noise
(Lm-1)
(dB)
No-load
Current
(%)
Base Frame
Q1XQ2
(mm)
Weight
(kg)
Outline Dimension
(LengthxWidthxHeight)
(mm)
Enclosure Dimension
(IP20/IP21)
(LengthxWidthxHeight)
(mm)
200 0.88 3.32
6
50 1.1 660×660 1330 1540×760×1720 2300×1800×2200
250 0.99 3.80 50 1.1 660×660 1590 1600×760×1780 2300×1800×2200
315 1.17 4.51 50 1 820×820 1790 1700×920×1690 2300×1800×2200
400 1.37 5.41 50 1 820×820 2180 1820×920×1780 2500×1800×2200
500 1.62 6.65 50 1 820×820 2280 1860×920×1750 2500×1800×2200
630 1.86 7.69 50 0.85 820×820 2580 1920×920×1820 2600×2000×2200
800 2.16 9.12 52 0.6 820×820 3140 1980×920×1940 2600×2000×2400
1000 2.43 10.40 52 0.6 820×820 3280 2020×920×1960 2700×2200×2400
1250 2.83 12.70 54 0.5 820×820 3690 2080×920×1980 2700×2200×2400
1600 3.24 15.40 56 0.5 1070×1070 4920 2180×1150×2090 3000×2200×2500
2000 3.82 18.20 58 0.5 1070×1070 5580 2280×1150×2120 3000×2200×2500
2500 4.45 21.80 60 0.5 1070×1070 6170 2400×1150×2280 3100×2200×2700
3150 5.29 28.50
8
64 0.5 1070×1070 7630 2480×1250×2360 3100×2400×2800
3500 5.72 30.80 68 0.5 1070×1070 8260 2580×1300×2480 3100×2400×2800
HV Voltage:33kV/34.5kV/35kV /37kV
LV Voltage:400V/415V/420V/433V
Frequency:50Hz/60Hz
HV tapping:±2*2.5%/±5%
Vector group:Dyn11/Dyn5/Dyn1/Yyn0
Material of winding:Copper
HV Voltage:33kV/34.5kV/35kV /37kV
LV Voltage:400V/415V/420V/433V
Frequency:50Hz/60Hz
HV tapping:±2*2.5%/±5%
Vector group:Dyn11/Dyn5/Dyn1/Yyn0
Material of winding:Aluminum
Remark: Eaton reserves the right to make changes or modify the contents of this catalogue without prior notice.
Eaton CRT can be designed and manufactured as per GB/IEC/ANSI standards.
16
Product Electrification Criteria
35kV Class 4000~25000kVA Power Transformer(Copper Winding)
35kV Class 4000~25000kVA Power Transformer(Aluminum Winding)
Rated
Power
(KVA)
No-load
Loss
(kW)
On-load
Loss 120℃
(kW)
Short
Circuit
Impedance
(%)
Noise
(Lm-1)
(dB)
No-load
Current
(%)
Base Frame
Q1XQ2
(mm)
Weight
(kg)
Outline Dimension
(LengthxWidthxHeight)
(mm)
Enclosure Dimension
(IP20/IP21)
(LengthxWidthxHeight)
(mm)
4000 7.02 29.4
8
64 0.70 1475×1070 10555 3230×1400×2100 4000×2400×3000
5000 8.37 34.9 66 0.60 1475×1070 12850 3300×1400×2250 4000×2400×3000
6300 9.9 40.8 66 0.60 1475×1070 16765 3505×1400×2330 4200×2400×3000
8000 11.3 46.0
9
68 0.50 1475×1475 18400 3755×1800×2700 4500×2800×3200
10000 12.9 55.5 68 0.50 2040×1475 22200 3900×1800×2950 4600×2800×3500
12500 15.7 64.6 70 0.40 2040×1475 28000 4095×1800×3040 4800×2800×3500
16000 19.3 76.0 70 0.40 2040×1475 31000 4105×1800×3100 4800×3000×3600
20000 22.9 85.5
10
74 0.35 2040×1475 34800 4295×1800×3200 5000×3000×3600
25000 27.1 101.0 74 0.35 2040×1475 38000 4400×1800×3400 5200×3000×3800
Rated
Power
(KVA)
No-load
Loss
(kW)
On-load
Loss 120℃
(kW)
Short
Circuit
Impedance
(%)
Noise
(Lm-1)
(dB)
No-load
Current
(%)
Base Frame
Q1XQ2
(mm)
Weight
(kg)
Outline Dimension
(LengthxWidthxHeight)
(mm)
Enclosure Dimension
(IP20/IP21)
(LengthxWidthxHeight)
(mm)
4000 7.02 29.4
8
64 0.70 1475×1070 9600 3300×1400×2300 4100×2400×3000
5000 8.37 34.9 66 0.60 1475×1070 11600 3380×1400×2555 4100×2400×3000
6300 9.9 40.8 66 0.60 1475×1070 15200 3580×1400×2730 4200×2400×3200
8000 11.3 46.0
9
68 0.50 1475×1475 16600 3840×1800×2800 4500×2800×3200
10000 12.9 55.5 68 0.50 2040×1475 20800 3980×1800×3150 4700×2800×3500
12500 15.7 64.6 70 0.40 2040×1475 25800 4160×1800×3240 4900×2800×3500
16000 19.3 76.0 70 0.40 2040×1475 27900 4200×1800×3260 4900×3000×3600
20000 22.9 85.5
10
74 0.35 2040×1475 31800 4380×1800×3380 5100×3000×3800
25000 27.1 101.0 74 0.35 2040×1475 35000 4600×1800×3500 5300×3000×4000
HV Voltage:33kV/34.5kV/35kV /37kV
LV Voltage:6kV/6.3kV/10kV /11kV
Frequency:50Hz/60Hz
HV tapping:±2*2.5%/±5%
Vector group:YNd11/ Yd11/ Dyn11/Yyn0
Material of winding:Aluminum
HV Voltage:33kV/34.5kV/35kV /37kV
LV Voltage:6kV/6.3kV/10kV /11kV
Frequency:50Hz/60Hz
HV tapping:±2*2.5%/±5%
Vector group:YNd11/ Yd11/ Dyn11/Yyn0
Material of winding:Copper
Remark: Eaton reserves the right to make changes or modify the contents of this catalogue without prior notice.
Eaton CRT can be designed and manufactured as per GB/IEC/ANSI standards.
17
干式变压器 Product Design
Design
H
L
Q1
Q2
W
18
Key Markets
Healthcare
Industry
Utilities
Data center
Commercial buildings
Renewable energy
19
Eaton Corporation
No.3, Lane 280. Linhong Road.
Changning District,
Shanghai, China 200335
Eaton Transformer (Jiangsu) Co., Ltd.
No. 88-9, West Changjiang Road,
Haian, China 226600
© 2023 Eaton Corporation
Al Rights Reserved
Printed in China
June 2023
Eaton is a registered trademark of
Eaton Corporation.
Al trademarks are property of their
respective owners.
Eaton is an intelligent power management company dedicated
to improving the quality of life and protecting the environment
for people everywhere. We are guided by our commitment to do
business right, to operate sustainably and to help our customers
manage power - today and well into the future. By capitalizing on
the global growth trends of electrification and digitalization, we’re
accelerating the planet’s transition to renewable energy, helping to
solve the world’s most urgent power management challenges, and
doing what’s best for our stakeholders and all of society.
Eaton was founded in 1911 and has been listed on the New York
Stock Exchange since 1923. We reported revenues of $20.8 billion
in 2022 and serve customers in more than 170 countries. Eaton
entered the Chinese market in 1993 and has grown significantly
since then. In 2004, Eaton moved its Asia-Pacific headquarters from
Hong Kong to Shanghai. Today, Eaton has nearly 9,000 employees
and 20 manufacturing facilities in China. Eaton is marking its 100th
anniversary of being listed on the New York Stock Exchange, and its
30th anniversary of being in Chinese market.
For more information about Eaton China, visit www.eaton.com.cn
Follow Eaton China WeChat account: Eaton_China