Hardware Configuration Solution
for Rail Transit
Hardware Configuration Solution for Rail Transit
Typical Locks &
Hardware Brochure
Trane Protective Film
Product Catalog
Hardcover House
Hardware Configuration
Atlas
School Hardware
Configuration Brochure
Typical Bathroom
Hardware Atlas
Fire Door Hardware
Integration Brochure
Railway Hardware
Configuration Brochure
Hospital Hardware
Configuration Brochure
Typical Shower Room
Products
Shower Bathroom Hardware
Scene Integrated Product
Gallery
Apartment-Hotel Hardware
Configuration Brochure
Factories-Malls-Offices
Hardware Configuration
Solutions
For more product information, please scan the QR code in the image above
CONTENTS
Tender Technical Requirements Template .....05
Hardware Configuration Sheet Template.......11
Key Management System..............................13
Railway Transportation Total Solution...........15
Door Lock Hardware Series......... ..................37
Door Control Hardware Series.......................71
Bathroom Hardware Series...........................77
Project References........................................03
Anti-theft lock series.............................................................. 47
Escape push bar lock series...................................................50
American standard series...................................................... 39
Fire lock series.......................................................................58
Airtight lock..............................................................................56
Mechanical and electrical integrated lock series...................62
Hardware accessories series .................................................65
Kitchen hardware series.........................................................81
European standard series...................................................... 43
Tube well Lock series..............................................................60
Public accessories series........................................................83
Door closer series....................................................................72
Hardware Configuration Solution for Rail
Transit (American Standard Series)................19
Hardware Configuration Solution for Rail Transit
(European Standard Series)...........................28
01
Integrated Solutions Provider R & D patent
There are more than 800 patents in
domestic and abroad
It has more than 10000 products and
a constantly updated product library
More than 4000 sales service teams
from more than 500 sales service
institutions in domestic and abroad
Stock storage system
Professional installation team
Perfect logistics distribution system
R & D support
Product support
Service support
Warehousing, logistics,
installation support,
R & D Integration
Product integration
Service integration
Warehousing, logistics, installation integration
Product category
Organization and
team
Integrated system
02
CERTIFICATE OF COMPLIANCE
Certificate Number 20190510-R39782
Report Reference R39782-20190111
Issue Date 2019-May-10
Bruce Mahrenholz, ctor North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 2
Issued to: GUANGDONG KIN LONG PRECISION PRODUCTS CO
LTD
NO.88 Guangfu Rd, Tongle Village,Dongsheng Town
Zhongshan City, Guangdong 528414 CHINA
This certificate confirms that
representative samples of
SINGLE-POINT LOCKS AND LATCHES
See Addendum Page for Models/Product
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: ANSI/UL 10C - Positive Pressure of Fire Tests of Door
Assemblies
Additional Information: See the UL Online Certifications Directory at
https://iq.ulprospector.com for additional information.
This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow-Up
Services Procedure provides authorization to apply the UL Mark.
Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL’s
Follow-Up Services.
Look for the UL Certification Mark on the product.
Certificates from authorities
03 Shijiazhuang Metro Nanning Metro
04
Luoyang Rail Transit
Beijing New Airport Terminal
05 1、 Code and Standards
2、Technical Requirements
2.1、 Requirements for American standard mortise locks
2.1.1 General requirements
2.1.2、American standard storage room lock (used for equipment room doors)
Functional requirements for use
Product standards and code, engineering standards and code, acceptance standards and specifications include (but are
not limited to):
GB12955-2015《Fire resistant doorsets》
GB/T20909-2017《Steel windows and doors》
GB17565-2007《General specification burglary resistant safety door》
GB15763.1-2009《Safety glazing materials in building - Part 1: Fire resistant glass》
GB16809-2008《Fire resistant windows》
17J610-1《Special doors and windows》
GB14102-2005《Fire resistant shutter》
GB50877-2014(2019 version)《Code for installation and acceptance of fire resistant shutters,fire resistant doorsets and fire resistant windows 》
GB/T7106-2019《Graduations and test methods of air permeability, watertightness, wind load resistance performance for building external windows and doors》
04J631《National Architectural Standard Design Institute for Hardware Accessories for Doors, Windows, Curtain Walls and Windows;》
GA93-2004《Fire-proof door closer》
JG/T268-2019《Door Closers for Construction》
QB/T 2474-2017《Mortise locks》
GA/T73-2015《Burglary-resistant mechanical locks》
GB16807-2009 《Fire intumescent seals》
GB50157-2013 《Code for design of metro》
DB11/995-2013 《Code for design of urban rail transit engineerin》
GB51298-2018 《Standard for fire protection design of metro》
GB50016-2014(2018 Version)《Code for fire protection design of buildings》
GB 50352-2019 《Uniform standard of civil buildings》
The product standards and code involved in the equipment; Engineering standards and code; The acceptance standards, specifications,
etc. shall fully comply with all current regulations and specifications of the People's Republic of China, including but not limited to the
above content. The above code and standards have the terms of this standard by quoted in this requirement. All code and standards
default to the latest version of these files. For any discrepancies with the current version , the latest version shall prevail.
1)The performance meets the first level standard of ANSI/BHM A156.13, and a third-party certification report is required.
2)The service life is over 1 million times, a third-party certification report is required.
3)Precision cast stainless steel with a length of no less than 19mm, three section anti friction latch bolt, and all locking bolt
should not contain any non-metallic materials such as plastic. Adopting precision cast stainless steel split solid handle, with a
surface treatment of forged stainless steel color. Standard installation center distance 70mm,
4)The lock body material should be made of high-strength steel, which has undergone anti-corrosion treatment. The key
moving parts of the door lock should be made of steel stamping, and the load-bearing parts should be precision cast stainless
steel. Brass or other soft metals cannot be used. The lock body should be equipped with a stainless steel locking buckle plate
that meets ANSI standards, with a guide bolt, and no distinction between left and right hands. The locking bolt can be reversed
and adjusted on-site to adapt to the left and right hand door orientation.
5)The lock body should use high-strength springs to ensure the normal rebound of the handle and prevent the handle from
sagging during use. The handle shaft should be made of corrosion-resistant reinforced steel with sufficient length to adapt
to different thicknesses of the door leaf. The indoor and outdoor handles should be designed separately to ensure separate
operation.
6) Doors with fire protection requirements and locks on the doors should pass the 1.5 hour fire protection type inspection
required by the national standard GB12955-2008, and provide a third-party certification report.。
Proposal Technical Requirements Template
06
2.1.3、 American standard classroom lock (used for cable rooms, air rooms, air ducts, etc.)
Functional requirements for use:
2.1.4、American standard corridor lock (for corridor doors)
Functional requirements for use:
2.1.5、American standard apartment lock (used for employee dormitories)
Functional requirements for use:
2.1.6、 American standard public restroom indicating lock
Functional requirements for use:
2.1.7、American standard dormitory locks
1) Inside the door: Pressing the handle inside the door at any time can simultaneously retract the inclined bolt and safety
bolt, achieving a single action emergency escape function.。
2)Outside the door: The outside handle is always fixed and cannot rotate. The door automatically locks when closed. After
locking, use the key to open the door. When the door is closed, assist the safety bolt to lock the latch bolt. Equipped with a
mechanical lock cylinder on the outside.
1) Inside the door: Pressing the handle inside the door at any time can simultaneously retract the latch bolt and safety bolt,
achieving a single action emergency escape function.
2)Outside the door: The door is locked with a key, but cannot be locked inside. After locking, use the key to unlock the door.
When the door is closed, assist the safety bolt to lock the latch bolt. Equipped with a mechanical lock cylinder on the outside.
Press the handle inside and outside the door at any time to retract the latch bolt to unlock, without a lock cylinder.
1)Inside the door: Pressing the handle inside the door at any time can simultaneously retract the latch bolt and safety ,
achieving a single action emergency escape function.
2)Lock the door with a key outside the door. After locking, unlock the door with the key. When the door is closed, assist the
safety bolt to lock the latch bolt. Equipped with a mechanical lock cylinder on the outside.
3)Lock the door with a knob to active deadbolt.
Inside the door: 1) Press the handle inside the door at any time to retract both the latch bolt and the safety bolt, achieving an
emergency escape function in one action.
2) Use the knob to active the deadbolt lock it
Outside the door: 1) In any case, can use coins to retract deadbolt outside the door at anytime, and the device has a usage status
indicator function
2)When locking with a knob indoors (with the bolt actived), the outer handle cannot be pressed down to unlock
3.)When the dead bolt retracts, the outer handle can be pressed down to unlock.
Inside the door: 1) Press the handle inside the door at any time to retract both the latch bolt and the safety bolt, achieving an
emergency escape function in one action.
2)Use the knob to active deadbolt and lock the outer handle at the same time.
Outside the door: 1) The key can unlock under any circumstances.
2)When locking with a knob indoors (with the bolt actived), the outer handle cannot be pressed down to unlock.
3)When the dead bolt retracts, the outer handle can be pressed down to unlock.
2.1.8、American standard office locks
Inside the door: 1) Press the handle inside the door at any time to retract both the latch bolt and the safety bolt, achieving an emergency
escape function in one action.
2)Use the knob to lock or unlock the outer handle.
Outside the door: 1) The key can unlock under any circumstances.
2) Lock or unlock the external handle with the key.
3)When the outer handle is locked, the outer handle cannot be pressed down to unlock it.
2.2、Requirements for anti-theft locks
Inside the door: 1) Press the handle inside the door at any time to retract both the latch bolt and the deadbolt, achieving an
emergency escape function in one action.
07 2.3 Requirements for European standard mortise locks
2.3.1 General requirements
2.4 Requirements for airtight locks
2.5、American standard door closer
2.6、European standard door closer
2.7、American standard hinge
The lock body has passed EN12206 Level III testing and CE certification, with an opening life of over 200000 times.
Doors with fire protection requirements and locks on the doors should pass the 1.5 hour fire protection type inspection required by the
national standard GB12955-2008, and provide a third-party latch bolt .The functions include corridor lock, bathroom lock, door lock,
indicator bathroom lock, office lock, deadbolt lock, storage room lock, and classroom lock.
1)The product meets the requirements of GB/T7106-2019, and the wind resistant surface can withstand a pressure of 3000Pa. The door
leaf bears an impact load of 294N and has a lifespan of 500000 times.
2)Handwheels are installed on both sides of the door, both inside and outside, and the door leaf can be opened through the handwheel
3)3 point fastening (top, bottom, middle)
1)The door closer should comply with ANSI A156.4-200I A156.4-2000 Class I standard and be certified. It has been opened more than
2 million times and has passed the UL3-hour fire protection certification of the American Business Laboratory. It meets the relevant
requirements of GB12955-2008 and has passed the fire protection type test of the China National Fixed Fire Extinguishing System and
Refractory Component Quality Supervision and Inspection Center.
2)The door closer should be made of high-strength steel, with independent door opening buffer adjustment function, door closing
speed and locking speed adjustment function. The door closer has adjustable force levels 1 to 6, suitable for a maximum door width of
1524mm, and comes with a protective cover.
3)The surface treatment of the door closer meets the corrosion resistance salt spray test standard for more than 100 hours, and the silver
electrostatic spraying surface is applied.
4)The door closer should have no distinction between left and right door orientations, and should be equipped with a parallel arm
mounting plate as standard. The outer door closer should be equipped with a high-strength parallel arm mounting plate with a door stop
function.
5)The door closer should have no distinction between left and right door orientations, and should be equipped with a parallel arm
mounting plate as standard. The outer door closer should be equipped with a high-strength parallel arm mounting plate with a door stop
function.
1)The door closer should pass EN1154 testing and have CE certification, with a lifespan of over 500000 times, meet the relevant
requirements of GB12955-2008, and pass the fire protection type test of the China National Fixed Fire Extinguishing System and
Fireproof Component Quality Supervision and Inspection Center.
2)The door closer should be made of high-strength steel, with independent door opening buffer adjustment function, door
closing speed and locking speed adjustment function.
3) The number of hinges is determined based on the height of the door. Generally, one hinge is used for every 762mm of the door
height, specifically:
Door height ≤ 1524mm:2 pieces
1524mm < door height ≤ 2286mm:3 pieces
2286mm < door height ≤ 3048mm:4 pieces
1)Ordinary hinges should comply with the American standard ANSI/A156.1-2006 Class II standard, and can be opened more
than 1.5 million times. A third-party certification report is required. The hinges used for fire doors must pass the 1.5 hour fire test
required by the national standard GB12955-2008 and have a report
2)The ordinary door adopts a stainless steel hinge with 5 sections and 2 oil lubricated ball bearing structures, with a satin
stainless steel finish. The access door or tube well door adopts a 3 section steel spring hinge,
2) Use the knob to active or retract the safety bolt.
3)The inner handle can be lifted backwards to active the deadbolt.
Outside the door: 1) The key can open the fixed deadbolt and latch bolt, but cannot open the safety bolt.
2)The outer handle can be lifted backwards to active the deadbolt.
3)The outer handle cannot be pressed down and the latch bolt cannot be tilted.
The entire product meets the B-level requirements of the GA73-2015 \"Burglary-resistant mechanical locks\" standard, with the lock cylinder
meeting the C-level requirements and a test report from the Testing Center of the Ministry of Public Security
08
2.8、European standard hinge
2.9、Door pivot
2.10、American standard escape device
2.11、European standard escape devices
2.12.Floor hinge
2.13、 Interval escape device (four lock point type)
4)Model and size: Ordinary hinge H1:114 × 114 × 3.4 mm
Crossing hinge EH: 114 × 114 × 3.4 mm
5)The manufacturer's trademark should be etched on the front of each hinge to enable identification of the hinge manufacturer even
after the door is installed.
1)Tested according to the European standard EN 1935:2002 and CE certified, with up to 200000 opening times;
2)Must pass the 90 minute fire test required by the national standard GB12955-2008 and provide a test report.
1) To install steel or eccentric heaven and earth door shafts for closed doors or wind resistant doors, the door shaft must have a loadbearing capacity of over 275kg, a lifespan of over 500000 times, and can withstand positive and negative wind pressures of 6000 Pa. There
is a third-party test report.
2)The shootbolt lock system can be provided in various specifications that are suitable for different door types. For doors with a height
exceeding 2.0m, an intermediate shaft must be installed at the center line of the height.
3)Should pass the 1.5 hour fire test required by the national standard GB12955-2008 and have a report.
1)The tunnel passage door adopts a flat push escape device, which meets the first level standard of ANSI A156.3-2001 and has been
certified. It has passed the UL3-hour fire protection certification of the American Underwriters' Laboratory, meets the relevant requirements
of GB12955-2008, and has passed the fire protection type test conducted by the China National Fixed Fire Extinguishing System and
Refractory Component Quality Supervision and Inspection Center for more than 1.5 hours.
2)The escape device push bar made of stainless steel material, and the fixing parts of the escape push bar should be designed reasonably
to ensure that any screw, bolt, or other fixing part falling off or loosening will not cause the escape push bar lock bolt to fail to operate.
3)The exterior handle style and surface treatment of the device should match other locks, and its lock cylinder can be included in a unified
master key management system with other locks.
4) The escape devices of the same series should have optional electronic control functions such as connecting with the access control,
electronic control handles, electronic control locks, status monitoring, local or remote alarms, and electronic control delayed exit.
1)Passed EN1125 testing and CE certification, with a lifespan of over 200000 cycles,
2)Must pass the 90 minute fire detection required by the national standard GB12955-2008 and provide a detection report
All floor hinges comply with EN 1154 standards, are suitable for doors weighing 300KG, have a 90 degree door stop function, have a lifespan
of over 500000 times, are made of 304 stainless steel, and have a surface hairline treatment.
1)Install interval emergency evacuation doors and escape doors at designated locations within the central area of the escape passage.
The installation of heavy-duty flat push escape devices for all interval emergency evacuation doors and escape doors should meet the
requirements of national standard commercial grade high-strength escape devices.
2)The fire door lock of the interval connecting passage must adopt an escape push bar device (upper, middle, and lower four point type),
which includes push bar (or press bar), fixed seats, lock bolts, lock seats, and other components. When pushed horizontally or pressed
down along the escape direction at any position of the effective length of the push bar on the inner side of the door, the lock bolt will retract
to release the locking function, achieving an emergency escape function. The outer side is equipped with a handle and lock cylinder.
3)It must be a product that has passed the verification of the National Fixed Fire Extinguishing System and the Quality
Supervision and Inspection Center for Refractory Components, and has a valid 90 minute fire protection type test
report. It must have been tested more than 500000 times, and corresponding test certificates must be provided for the
above standards;
4)The escape device must be equipped with a door lock cylinder and a fixed handle outside the door, which is made of
stainless steel; The handle style and surface treatment should match other locks. The device should have the feature of
quickly changing the door handle on site without distinguishing between left and right directions;
5)The section connecting passage fireproof door is required to be able to withstand wind pressure of 6000Pa.
2.14、Door hardware accessories
The door hardware provided by the bidder must be provided by the same manufacturer, and all small hardware components, such as
sequencers, door stoppers, bolts, dustproof boot, etc., must not be used interchangeably between two or more brands of small hardware
in the same door.
09 3)Push pull handle, skirting board and mop board, stainless steel pull plate, door stop:
The surface treatment is hairline stainless steel color. It must be fixed with threaded screws, and the surface treatment should be hairline
stainless steel color.
The door stop should be installed on the wall or on the ground according to the actual situation, and should not obstruct the normal passage
of people or affect the opening angle of the door leaf.
3、Installation Technical Requirements
4、Information to Be Provided by The Bidder
5、Product Delivery
1)Except for special specifications or certain control requirements, as well as those determined by the design unit, the installation
of hardware can be carried out in accordance with the specifications described in the National Building Standard Design Atlas 04J631
compiled by the China Building Standards Design and Research Institute;
2)Install each hardware according to the manufacturer's instructions and recommendations. Whether it is internal or surface
mounted hardware, if it needs to be cut or matched, it must be painted or finished on the door surface, removed, stored, reinstalled,
and subjected to surface protection treatment before proceeding. And only after the primer is completed can the hardware be
installed;
3)Set horizontal or vertical lines to ensure the correct installation position. If necessary, adjust and reinforce the base plate for
proper installation and operation.
1)Product information: According to the requirements, the bidder will submit the product technical information of each hardware
manufacturer, including necessary documents to prove compliance with the design requirements, installation instructions, and maintenance
instructions for operating components and finishes;
2)Hardware configuration table: The supplier shall prepare and submit the final hardware configuration table in the following form for
confirmation by the design unit and the tenderer before manufacturing. The content includes information such as the size of the door,
functional area, form of the door, opening direction, and hardware configuration of each door
3)The final hardware configuration table includes: based on the hardware summary table, the file configuration table is divided into
\"hardware groups\" according to the listed hardware, indicating the various hardware required for each door. Including the following
information:
a.The model, style, functional description, quantity, and finish of the hardware;
b.Hardware name and manufacturer;
c. The corresponding positions of hardware on doors and frames;
4)Before submitting the hardware configuration table and placing an order, the bidder must submit a set of exposed hardware samples
that meet the requirements listed in the hardware configuration table in this technical requirement, along with coordinated finishes, for
confirmation by the design unit and the bidder's representative;
5)The bidder shall provide samples for all doors, door frames, and other product manufacturers that require factory prefabrication for
the installation of hardware components.
1)Concealed double door sequencer: used to control the closing sequence of two doors to ensure correct closing and prevent stacking
a. Must pass the 90 minute fire test required by the national standard GB12955-2008 and provide a test report。
b. Built in high-strength spring double bolt structure.
c. All SUS304 stainless steel materials.
d. The warranty period is 2 years and a quality guarantee certificate issued by the manufacturer is required.
e. Location of use: All double leaf fire doors should be installed. If there is a conflict with the installation of the access lock or door closer,
a surface mounted double door sequencer can be used; Surface mounted double door sequencer: used to control the closing sequence
of two doors, it must pass the fire protection testing conducted by the national testing agency (in accordance with the fire protection
requirements of GB12955-2015 appendix), and have a 90 minute fire protection type effective testing report
2)Manual concealed bolt for steel door
a. Must pass the 90 minute fire proof type test certification required by GB12955-2015, and provide a copy of the certificate. Including
access doors and normally open fire doors for use.
b.Double door driven door leaf is used, and manual (automatic) latch should be provided with steel door according to the material of the
door body.
c.Double door height above 2300mm, with extended concealed latch (16 inches or longer) or automatic latch on the upper part.
d.The installation of concealed bolt and door leaf must be equipped with a dustproof boot.
10
6、Technical Documents And Materials
The bidder shall provide relevant technical data, including drawings, manuals, test reports, and other technical materials, in
accordance with the requirements of the User Requirements Specification and in combination with the characteristics of the
bidding product and the actual needs of this project.
Technical data should include but not be limited to the following:
1)List of product descriptions;
2)A detailed description of the main technical indicators and performance of the product;
3)Product related testing, inspection, and testing reports;
4)The main production process of the product;
5)The testing, inspection, and debugging methods of the supplied products;
6)Project implementation progress control plan;
7)Implementation plan for related services;
8)Analysis of product operation and maintenance costs;
1)Bidders should request hardware manufacturers to label and package each hardware item according to the hardware configuration
table, and attach basic installation instructions.
2)The hardware manufacturer will work with the bidder's representative or installer to count the provided hardware until the quantity is
correct and meets the contract requirements.
3)For the convenience of management, the tenderer proposes to use a master key system for the key of the station equipment
management room area, which is set according to the three-level key system and special keys. The details are as follows:
A.Primary key
The highest level key, the first level key, can open all doors of this station (except for special keys)
B. Secondary key
Professional key, secondary key can open all doors of a certain profession. Each profession can develop multiple secondary keys according
to their usage needs, and develop their own range of rooms that can be opened by secondary keys.
C.Third level key
A room key, a third level key, can open all the doors of a room.
D.Special key
a. The keys for opening the connecting passage doors and pump room doors of the entire line section are not included in the overall key
system, but are independently configured;
b.Special facilities such as other line rooms, police rooms, ticketing rooms, vending machine rooms, customer service centers, etc. in the
station equipment management area
The keys of the rooms are individually configured and are not included in the overall key system.
4)Among them, the station equipment rooms involved in the secondary key master key system are divided into three categories, so the
secondary keys are correspondingly divided into three categories. The classification requirements are as follows:
A: The first category is ventilation and air conditioning rooms, including chiller rooms, ventilation and air conditioning rooms, air ducts, air
chambers, etc;
B : The second category of B is the dynamic lighting room, including the lighting distribution room, environmental control and electrical
control room, etc;
C : The third category is water supply and drainage rooms, including sewage pump rooms, wastewater pump rooms, fire pump rooms, etc.
Note: The specific secondary key classification is subject to the final design liaison.
5)The bidder shall be responsible for keeping all hardware items that have been delivered to the site for use in the project but have not
yet been installed.
6)Explanation::
a.The bidder is required to select the appropriate hardware group from the hardware configuration table for each door of each station
within the scope of this bidding to configure door hardware. Doors that are not fully listed should be selected according to similar doors.
b.The principles and methods for applying hardware groups can be found in the notes after the hardware configuration table
c.In order to facilitate the management of lock cylinders and after-sales maintenance, all hardware products selected by the bidder
(including escape door locks and core locks, hinges, door closers, etc.) must be produced by the same manufacturer, and all door hardware
products should be supplied by the same supplier. The bidder is required to provide the bidder with product authorization documents
from the hardware manufacturer.
d.The door hardware supplier selected by the bidder should have professional planning and graphic integration capabilities for door
hardware to cope with potential hardware configuration changes caused by design changes.
11 Hardware Configuration Table Template
1 N4-01 GFM
GFSM
GHM
GFM
GFM
GFM
GFM
GFM
GHM
GFM
GFM
GFBM
GFSM
GFM
GHM
GFM
GHM
GHM
GFDM
GHM
GHM
GFM
GHM
N4-04
N4-07
N4-10
N4-02
N4-05
N4-08
N4-11
N4-03
N4-06
N4-09
N4-12
N4-13
N4-13
N4-14
N4-15
N4-16
N4-17
N4-18
N4-19
N4-20
N4-21
N4-22
2
Station Control
Room
Station master
Room
Meeting Room
Police Office
Changing room
Changing room
Connected aisle
Cleaning tool
room
washroom
washroom
AFC
Ticket Office
AFC
Ticket Office
AFC
AFC
Maintenance work area
Maintenance work area
Advertising spare
parts warehouse
Driver's cage
Train inspection
room
Ventilation and air
conditioning room
Vehicle repair
tool room
Thoroughfare
Air duct
Walkway
Anterior chamber
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Walkway
Right,
outside
Right,
Steel First class
First class
First class
First class
First class
First class
First class
First class
First class
First class
First class
First class
First class
First class
First class
classroom
lock
classroom
lock
classroom
lock
classroom
lock
classroom
lock
classroom
lock
Bathroom
lock
Bathroom
lock
Storeroom
lock
Storeroom
lock
Storeroom
lock
Storeroom
lock
Storeroom
lock
Storeroom
lock
Storeroom
lock
Channel
lock
Air tight
lock
Push bar
Push bar lock
against wind
pressure
Indicating
bathroom lock
Indicating
bathroom lock
Burglar-proof
lock
SHW-01
SHW-05
SHW-02
SHW-06
SHW-03
SHW-07
SHW-10
SHW-08
SHW-08
SHW-11
SHW-11
SHW-10
SHW-04
SHW-10
SHW-10
SHW-12
SHW-13
SHW-14
SHW-15
SHW-15
SHW-09
SHW-04
no SHW-04
no
no
no
no
no
no
no
1200 2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
2300
1000
900
1500
1500
1000
1000
1000
1000
1500
1200
1000
1500
1500
1200
1000
1000
1000
1200
1000
1000
1500
1000
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Steel
Right,
inside
Right,
inside
Right ,
inside
Right,
inside
Right ,
inside
Right,
inside
Right ,
inside
Right,
inside
Left,
inside
Left ,
inside
Left,
inside
outside
Double,
swing
Single
passage
Public
area
Air duct
Common
area
stairwell
4
6
7
10
3
5
8
11
9
12
13
14
15
16
17
18
19
20
21
22
23
Item Door
number
Door
code Room name Door
leaf
Opening Door Door Door Fireproof
Lock Hardware
direction material width height type Group
Outside
area
Push bar
Right,
outside
Left,
outside
outside
outside
outside
outside
outside
outside
outside
Right,
Right,
Right,
Left,
Left,
Left,
Left,
Double
Double
Double
Double
Double
Double
Double
Double
Double
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
Single
12
European
standard hinge
European standard
classroom lock
6
1
2
2
2
1
1
1
1
Pcs
Set
Set
Hairline
Hairline
KIN LONG
KIN LONG
KIN LONG
KIN LONG
KIN LONG
KIN LONG
KIN LONG
KIN LONG
KIN LONG
SHY403030-2BB
ST5572E5--
SSN12730FE
Pcs silver
silver
European standard
door closers
Overload the
sequencer
External single door
magnetic lock
Steel door latch
Dust cans
Half ball doorstop
Pcs KDS15010
SCX12701
4.0*4.0*3.0,200,000 lifetimes,304 stainless
steel main material
European standard EN12209,CE certification,
Passed 1.5 hours of fire resistance testing
and 200000 life tests;
Deputy lock SSN12730-False lock Dummy handle
When power off, the door will be open
Pcs
Pcs
Pcs
Pcs
SSW12604
BBM90105
304 stainless steel,Passed 1.5 hours of fire
resistance testing
304 stainless steel main material, used with latch
European standard EN1154,500,000 lifetimes
SFT12801
SMX12211 304 stainless steel material
6 \"steel door manual hidden latch
Product name Quantity Unit treatment Function description
Hardware group:SHW-01
Brand Model number
Hardware group template
Hairline
Hairline
Hairline
Surface
Hairline
Hairline
13 GGMK
GMKB
KBB2
MKBB
MKBA
MKAB
MKAA
GMKA
KBB1
KBA2
KBA1
KAB2
KAB1
KAA2
KAA1
Key management system
Key management system
architecture diagram:
Key management systems are often used in apartments, office buildings, commercial spaces and other places. Various sizes, forms and
specials are produced according to different needs.
Functional lock cylinder. With a set of Kinlong Master Key, you can open any door of your company or home as you like, which is safe and
convenient.
The key management system is divided into two-level management lock cylinder, three-level management lock cylinder and four-level
management lock cylinder. The master key of a certain level can open the specified range
All door locks. For example, GMKA can open MKAA, MKAB, KAA1, KAA2, KAB1, KAB2, but cannot open the upper level GGMA
And door locks within the scope of GMKB. The dedicated key of each lock is an independent key, and only the matching lock can be opened.
This system makes the corresponding key management system according to the architecture of each
building
14
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
KIN L ONG
Subway project master key architecture diagram
Management center
Transfer center
Dispatch and
control center
Computer
room Office Office Ticketing Crew Office Office Maintenance
office Sub theme Maintenance
warehouse
Bathroom
changing
room
Warehouse Fire passage Warehouse
Administrative and
other departments
Maintenance
department
Security
department
Station maintenance
department
Engineering
maintenance
Cleaning
department
Various stations
Secondary management lock cylinder
The secondary management lock cylinder has a master key, which can open the lock
cylinder of the entire system.The lower level of the master key is divided into multiple
independent keys, and each key opens its own lock cylinder:
MKA
Personal key
Master key
Lock cylinder
15 Hotel hardware decoration solution
Rail transit
hardware
(Catalogue) Hotel hardware hardware Shopping mall
Kinlong offers comprehensive hardware
solutions for eight key sectors.
16
hardware Office building
School
hardware
hardware Hardbound room
Hospital Airport hardware
hardware
17 19 Equipment room Hardcover matching Escape passage
Fire door Platform level
Tunnel area Platform level
Movable rail
Telescopic railing
Seats/stainless steel trash cans
Movable rail
Telescopic railing
stainless steel trash cans
On-off arrow/sign/blind path sign/blind path
Hall level
Escape lock
Air duct sealed door
Gas-tight door
Tunnel section gate
Access door
Fire door
Fire door
Waiting area
Bathroom door
Shaft lock/trap door (fire hydrant)
Equipment housing area
Escape door
Security door
Access control system
18 20
Public area Public toilet
Bathroom partition hardware
Ceramic sanitary ware
Toiletry hardware
Separate toilet Changing room
Matching hardware
Bathroom partition hardware Bathroom partition hardware
Ceramic sanitary ware
Toiletry hardware
Safety handrail
Fire door
Equipment/
management occupancy area
Escape door
Security door
Access control system
Common area
Pipe door/trap door (fire hydrant)
Bathroom door Pipe door/trap door (fire hydrant)
Channel region
Open the door with a frame
Hall level
19 Hardware Configuration Solution for Rail Transit
(American Standard Series)
20
Hardware configuration of spare parts warehouse locks
Hardware configuration of station control room locks
Product name Product model Material Unit Quantity
Aluminum alloy
304 stainless steel Set 1
304 stainless steel
304 stainless steel
Set 1
Pair
Pcs
1.5
1
American standard storage
room function lock
American standard
door closer
American standard
level-ll hinge
Door stopper
Equipment room
Spare parts warehouse
High voltage room
Weak current room
ST7092A6-SMB10213
BBM60006
SHY454034-2BB
SMX12211
American standard
classroom lock
Hidden sequencer
ST7092A5-SMB10213
SSW12603
Set
Pcs
1
1
False lock
Steel door automatic
latch
SMB10213
SCX12710
Set
Pcs
1
2
Dustproof cylinder
American standard
door closer
Door stopper
SHY454034-2BB
SFT12801
BBM60006
SMX12211
Aluminum alloy
Pair
Set
Pcs
Pcs
3
1
2
2
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
A m e r i ca n sta n d a rd
level-II hinge Station controller
Conference room
Environmental control
electric control room
Application
Scenarios
Application
Scenarios
21 Walkway lock hardware configuration
Lounge lock hardware configuration
Aluminum alloy
Set 1
Set 1
Pair
Pcs
1.5
Door stopper 1
Office
Lounge
Tool room
ST7092A3-SMB10213
BBM60006
SHY454034-2BB
SMX12211
A m e r i ca n sta n d a rd
door closer
A m e r i ca n sta n d a rd
office locks
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
A m e r i ca n sta n d a rd
level-II hinge
ST7092A1-SMB10213
SSW12603
Set
Pcs
1
1
Deputy lock
American standard
channel lock
SMB10213
SCX12710
Set
Pcs
1
2
Dust-proof cylinder
Concealed sequencer
Steel door
automatic latch
American standard
door closer
Door stopper
Walkway
Equipment area
passage
SHY454034-2BB
SFT12802
BBM60006
SMX12211
Aluminum alloy
Pair
Set
Pcs
3
1
2
2
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
Pcs
A m e r i ca n sta n d a rd
level-II hinge
Application
Scenarios
Application
Scenarios
22
Hardware configuration of mother and baby room lock
Hardware configuration of self-service ticket vending machine room locks
Anti theft lock
Vending machine rooms
AFC ticketing room
SFDS0207-68 Set 1
Anti-theft hinge
Door stopper
SHY12112
SMX12211
Pair
Pcs
1.5
1
A m e r i ca n sta n d a rd
door closer BBM60006 Aluminum alloy Set 1
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
Aluminum alloy
Set 1
Set 1
Pair
Pcs
1.5
1
American Standard
Dormitory Locks
Delayed door closer
Changing room
Baby room
Accessible bathroom
Door stopper
ST7092AB-SMB10213
BBM90115
SHY454034-2BB
SMX12211
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
A m e r i ca n sta n d a rd
level-II hinge
Application
Scenarios
Application
Scenarios
23 Hardware configuration of locks in public restroom
Hardware configuration of tea room locks Door stopper
Sliding plate
Bead lock
Pantry
Office restroom
SFZ11206
SMX12222
Set
Pcs
1
1
SHY454034-2BB 1.5
BBM60006
STB12901
Aluminum alloy Set
Set
1
1
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
A m e r i ca n sta n d a rd
level-II hinge
American standard
door closer
Aluminum alloy
Set 1
Set 1
Pcs
1.5
Door stopper 1
Changing room
ST7092A9-SMB10213
BBM60106
SHY454034-2BB
SMX12211
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
A m e r i ca n sta n d a rd
level-II hinge
American standard
door closer
P u b l i c B a t h r o o m
Bathroom
American standard
indicating bathroom lock
Application
Scenarios
Application
Scenarios
Pair
Pair
24
上门轴
中门轴
下门轴
Hardware configuration of safety exit locks
Hardware configuration of locking devices for section communication channels
STS11801
BBM60006
Set
Set
1
2
STS11802
SSW12604
Set
Pcs
1
1
Door stopper
Emergency Exit
Staircase
Equipment area passage
Heavy duty sequencer
External handle lock STS11810
SMX12222
SHY454034-2BB
Set
Pair
1
2
3
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel Pcs
A m e r i ca n sta n d a rd
level-II hinge
A m e r i c a n s t a n d a r d
horizontal push bar lock
American standard shootbolt
lock push bar system
American standard
door closer
Set 1
Aluminum alloy
Set 1
Set
Set
1
1
Section connection
channel
STS11510
STS11712
BBM60206
SHY12140F
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
American standard
door closer
Eccentric door spindle
External handle lock
Four point anti wind
pressure push bar lock
Application
Scenarios
Application
Scenarios
25 New air duct door lock hardware configurati
Hardware configuration ofsignal equipment room locks
Aluminum alloy
Set 1
Set 1
Pcs
1.5
Door stopper 1
New air duct door
Airtight lock SQM46032
BBM60006
SHY454034-2BB
SMX12222
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
A m e r i ca n sta n d a rd
secondary hinge
American standard
door closer
Door stopper
Integrated access
control machine
Power distribution room
Signal equipment room
Station master's room Wire breaker
American standard
mechatronic lock CML850
SMX12211
KDM22020
Set
Pcs
Set
1
1
1
BBM60006 Aluminum alloy Set 1
SHY454034-2BB
SGX12801 Set
1.5
1
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
Plastic
A m e r i ca n sta n d a rd
secondary hinge
American standard
door closer
Application
Scenarios
Application
Scenarios
Pair
Pair
26
Hardware Configuration of Public Bathroom Bathroom
Accessible bathroom bathroom hardware configuration
WSZ45981
WSZ7105B
WDQ20030
WDL3931C-75
WZH10160
WZH20080
WFJ41030
WSZ96220
WSZ96040
Product Model Picture Material
Angle valve
Pop-up drain
Soap
dispenser
Drain pipe
Hand dryer
Floor drain
Tissue box
ABS/white
ABS/white
304 stainless steel
/Matte
Stainless steel
/hairline
304 stainless steel
/Satin
Brass/
chrome plated
Brass/
chrome plated
Brass/
chrome plated
Brass/
chrome plated
WSZ96040
WZH20080
WSZ45981
WFS42110
WFS42090
WDL3931C-75
WFS41010
WSZ7105B
WDQ20030
Product Model Picture Material
Pop-up drain
Hand dryer
Floor drain
Safety
handrails
Safety
handrails
Safety
handrails
Angle valve
Nylon+
304 stainless steel
Nylon+
304 stainless steel
Nylon+
304 stainless steel
304 stainless steel
/Satin
304 stainless steel
Brass/
chrome plated
Brass/
chrome plated
Brass/
chrome plated
ABS/white
Sensor faucet
Integrated trash bin &
toilet paper dispenser
Integrated trash bin &
toilet paper dispenser
Sensor faucet
27 防盗门锁系列 WSZ44010
WYG11080
Angle valve WSZ71090
Product Model Picture Material
304 stainless steel
304 stainless steel
304 stainless steel
Basin faucet
Sinks WCP12226
WSH2008A
WFG41020
WSZ45981
WSZ96030
WSZ96220
WSZ71090
HDPE/ grey
Induction
faucet
Angle valve
Product Model Picture Material
304 stainless steel
304 tainless steel
/Satin
Pop-up
drain
Drain pipe Brass/Satin
Brass/
chrome plated
Brass/
chrome plated
Hardware configuration of mother and baby room bathroom
Tea room bathroom hardware configuration
Kitchen Shelves Zinc Alloy/Mirror
Bathroom
Seats
Integrated trash
bin & toilet
paper dispenser
28
Hardware Configuration Solution for Rail
Transit(European Standard Series)
29 ST6072E6-SSN12730 Set 1
SHY404030-2BB Pair 1.5
Door stopper
Equipment area
Spare parts warehouse
Strong (weak)
electrical room
European standard
door closer
European standard hinge
European standard
storage room lock
BBM90006
SMX12211
aluminum alloy Set
Pcs
1
1
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
Hardware configuration of weak current room locks
Hardware configuration of locks in the environmental control electric control room
ST5572E5-SSN12730
SSW12602
Set
Pcs
1
1
SSN12730
SCX12701
Set
Pcs
1
2
European standard hinge
European standard
door closer
European standard
classroom lock
Manual latch for steel
doors
Station controller
Meeting Room
Environmental control
electric control room
SHY404030-2BB
SFT12801
BBM90006
SMX12211
aluminum alloy
Pair
Set
Pcs
Pcs
3
1
2
2
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
Deputy lock
Sequencer Application
Scenarios
Application
Scenarios
Door stopper
Dust socket
30
Walkway lock hardware configuration
Office lock hardware configuration
aluminum alloy
Set 1
Set 1
Pair
Pcs
1.5
Door stopper 1
Office
Lounge
Tool room
SSN12730FE
BBM90006
SHY404030-2BB
SMX12211
European standard
door closer
European standard hinge
European standard
office lock
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
ST6072E1-SSN12730FE
SSW12602
Set
Pcs
1
1
SSN12730
SCX12701
Set
Pcs
1
2
Door stopper
Manual latch for
steel doors
SHY404030-2BB
SFT12802
BBM90006
SMX12211
Aluminum alloy
Pair
Set
Pcs
Pcs
3
1
2
2
European standard
door closer
European standard hinge
European standard
channel lock
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
Sequencer
Equipment area passage
Walkway
Application
Scenarios
Application
Scenarios
Dummy lock
Dust socket
31 Accessible bathroom lock hardware configuration
AFC ticketing room lock hardware configuration Set 1
Aluminum alloy
Pair 3
Set
Pcs
1
Door stopper 1
Anti theft hinge
Anti-theft lock SFDS0207-68
SHY12111
BBM90006
SMX12211
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
European standard
door closer
Ticket vending machine
room
AFC Ticket Office
Aluminum alloy
Set 1
Set 1
Pair
Pcs
3
Door stopper 1
ST6072E4-SSN12700
BBM90006
SHY404030-2BB
SMX12211
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
European standard
door closer
European standard
bolt lock
European standard hinge
Changing room
Nursery
Accessible restroom
Application
Scenarios
Application
Scenarios
32
Hardware configuration of lockers in the changing room
Hardware configuration of office restroom locks
Set 1
Aluminum alloy
Pcs 1
Pair
Pcs
3
Door stopper 1
Office restroom
Pantry Bead lock
Sliding plate STB12901
SFZ11206
SHY42135
SMX12222
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
Aluminum alloy
Set 1
Set 1
Pair
Pcs
3
Door stopper 1
ST6078E9-SSN12730
BBM900115
SHY404030-2BB
SMX12211
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
European standard
door closer
E u r o p e a n s t a n d a r d
indicating bathroom lock
European standard hinge
Public area restroom
changing room
Application
Scenarios
Application
Scenarios
Hydraulic hinge
33 Set 1
Aluminum alloy
Set 1
Set
Set
1
1
STS11510
STS11712
BBM60206
SHY12140F
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
Section connection
channel
Eccentric door spindle
American standard door
closer
External handle lock
Four point anti wind
pressure push bar lock
Upper door shaft
Middle door axis
Lower door shaft
Hardware configuration of staircase lock
Hardware configuration of locking devices for section communication channels STS11701
BBM90006 aluminum alloy
Set
Set
1
2
STS11702
SSW12604
Set
Pcs
Pcs
1
1
Door stopper
STS11712
SMX12222
SHY404030-2BB
Set
Pcs
1
2
6
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
European standard
door closer
Equipment area passage
Staircase
Emergency Exit
Overload sequencer
European standard hinge
External handle lock
European standard shootbolt
lock push bar system
E u r o p e a n s t a n d a r d
horizontal push bar lock
Application
Scenarios
Application
Scenarios
34
Hardware configuration of locks in the station master's room
New air duct door lock hardware configurati
Aluminum alloy
Set 1
Set 1
Pcs
Pcs
3
1
Airtight lock
Door stopper
New air duct door
SQM46032
BBM90006
SHY404030-2BB
SMX12222
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
European standard
door closer
European standard hinge
Door stopper
KDM22020
ST6072TD-SSN12730-EU
SMX12211
Plastic Set
Set
Pcs
1
1
1
BBM90115 Aluminum alloy Set 1
SHY404030-2BB
TD454030
Pcs
Pcs
2
1
Product name Product model Material Unit Quantity
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
European standard
door closer
Integrated access
control machine
European standard
mechatronic lock
European standard hinge
Power distribution room
Signal equipment room
Station master's room
Thread passing hinge
Application
Scenarios
Application
Scenarios
35 Hardware Configuration of Public Bathroom Bathroom
Accessible bathroom bathroom hardware configuration
WSZ96040
WSZ96220
WSZ45940
WSZ7110H/C
WDQ20010
WFS42110
WFS42090
WDL3931C-75
WFS41010
Brass/
chrome plated
Brass/
chrome plated
Brass/
chrome plated
Brass/
chrome plated
Nylon +
304 tainless steel
Nylon +
304 tainless steel
Nylon +
304 tainless steel
304 tainless steel
/Satin
ABS/white
Angle valve
Pop-up drain
Drain pipe
Hand dryer
Floor drain
Safety
handrail
Safety
handrail
Safety
handrail
Product Model Picture Material
WSZ45984
WSZ7110H/C
WDQ20010
WDL3012C
WZH10160
WZH30060
WFJ41030
WSZ96210
WSZ96010
Aluminum alloy
ABS/white
ABS/white
ABS
Angle valve 304 tainless steel
/Satin
Pop-up drain
Soap
dispenser
Drain pipe
Hand dryer
Floor drain
Tissue box
Tissue box
Brass/
chrome plated
Brass/
chrome plated
Brass/
chrome plated
304 stainless steel/
chrome plated
Product Model Picture Material
Sensor faucet
Sensor faucet
36
防盗门锁系列
Hardware configuration of mother and baby room bathroom
Tea room bathroom hardware configuration
WSZ44010
WYG11080
WSZ71090
304 stainless steel
304 stainless steel
304 stainless steel
304 stainless steel
Angle valve
Product Model Picture Material
Sink WCP12233
WSH2008A
WFG41010
WSZ96010
WSZ96210
WSZ71090
HDPE/grey
304 stainless steel
Brass/Satin
Brass/
chrome plated
Brass/
chrome plated
304 tainless steel
/Satin
Product Model Picture Material
Induction
faucet
Angle valve
Pop-up drain
Drain pipe
WSZ45984
Integrated
trash bin &
toilet paper
dispenser
Bathroom Seats
Basin faucet
Kitchen Shelves
37 Lock hardware typical
picture book
Door lock hardware series
38
39 American standard lock series
40
148
104.5
92 61.6
70
19
26
31.5
21.5
162
16
25
28
16.3
13
ST7092A American standard lock body
SMB10211 American standard fire lock
SMB10212 American standard fire lock
SMB10213 American standard fire lock
SMB10214 American standard fire lock
American standard handle cover ring SX-008 Cylinder 11,5
122
58
SMB10213F American standard fire lock
American standard lock fireproof series
Comply with American ANSI/BHMA A156.13 Grade 1 standard
Passed ANSI certification, passed UL certification
Suitable for steel or wooden entrance doors, villa doors, etc.
8 lock bodies with different functions to choose from,
suitable for different places
1 million times of opening life, sturdy and durable, the latch
bolt is adjustable
The function switch button can easily switch the function of
door lock and channel lock
The safety tongue can prevent the latch bolt from being
inserted
Equipped with s slot single row 6 ball marble lock cylinder
Center to center distance: 70mm
Hole center distance: 92mm
Applicable door thickness: above 45mm
(centered installation)
Each model has a different maximum door thickness
applies to. If it's beyond the max thickness, some
fiitings need be customized
Cover plate: 304 Stainless steel
Mounting screws: Stainless steel
Surface treatment:Stainless steel hairline
Function Model
Office lock
Classroom lock
Storage room lock
Dormitory Lock
Entry lock
Apartment lock
Indicative public
restroom lock
Channel lock ST7092A1-SMB10211
ST7092A3-SMB10211
ST7092A5-SMB10211
ST7092A6-SMB10211
ST7092A9-SMB10211
ST7092AB-SMB10211
ST7092AC-SMB10211
ST7092AD-SMB10211
Office lock
Classroom lock
Storage room lock
Dormitory Lock
Entry lock
Apartment lock
Indicative public
restroom lock
Channel lock
Model
ST7092A1-SMB10212
ST7092A3-SMB10212
ST7092A5-SMB10212
ST7092A6-SMB10212
ST7092A9-SMB10212
ST7092AB-SMB10212
ST7092AC-SMB10212
ST7092AD-SMB10212
Function
Office lock
Classroom lock
Storage room lock
Dormitory Lock
Entry lock
Apartment lock
Indicative public
restroom lock
Channel lock
Model
ST7092A1-SMB10214
ST7092A3-SMB10214
ST7092A5-SMB10214
ST7092A6-SMB10214
ST7092A9-SMB10214
ST7092AB-SMB10214
ST7092AC-SMB10214
ST7092AD-SMB10214
Function
Office lock
Classroom lock
Storage room lock
Dormitory Lock
Entry lock
Apartment lock
Indicative public
restroom lock
Channel lock ST7092A1-SMB10213
ST7092A3-SMB10213
ST7092A5-SMB10213
ST7092A6-SMB10213
ST7092A9-SMB10213
ST7092AB-SMB10213
ST7092AC-SMB10213
ST7092AD-SMB10213
Function Model
American standard apartment fire lock
American standard channel fire lock
American standard classroom fire lock
American standard storage room fire lock
ST7092A1-SMB10213F
ST7092A5-SMB10213F
ST7092A6-SMB10213F
SMB10213F
Function Model
Certified by ANSI and UL;
Comply with GB12955-2008 fire test
and pass fire protection certification;
41
American standard lock function introduction
1
2
3
4
5
6
7
8
ST7092A1
ST7092A3
ST7092A5
ST7092AC
ST7092A9
ST7092AB
ST7092AD
ST7092A6
KINL ONG
KIN L ONG
O
K G
N
NO. Function type Model Diagram Function description
Passage door
lock
Office lock
Classroom lock
Entrance door
lock
Indicative
public toilet
lock
Dormitory
lock
Apartment
lock
Storeroom
lock
Outdoor: Under any circumstances, the outer handle can be pressed down to
unlock
Indoor: Under any circumstances, the inner handle can be pressed down to
unlock
Outdoor: 1. The key can be unlocked at any time
2. The key locks or unlocks the outer handle
3. When the outer handle is locked, the outer handle cannot be pressed down
to unlock
Indoor: 1. The inner handle can be pressed down to unlock at any time
2. The knob can lock or unlock the outer handle
Outdoor: 1. The key can be unlocked at any time
2. The key locks or unlocks the outer handle
3. When the outer handle is locked, the outer handle cannot be pressed down
to unlock
Indoor: 1. The inner handle can be pressed down to unlock at any time
Outdoor: 1. The key can be used to unlock under any circumstances
2. When the room is locked with a key, the outer handle cannot be pressed
down, only the key can be used to unlock
Indoor: 1. The inner handle can be pressed down to unlock at any time
2. The key locks or unlocks the outer handle
Outdoor: 1. Coins can be used to retract the bolt outside under any circumstances, with
indication function
2. When the indoor knob is locked (with the tongue bolt out), the outer handle cannot be
pressed down to unlock
3. When the tongue is bolt, the outer handle can be pressed down to unlock
Indoor: 1. Under any circumstance, you can open the door by pressing the handle outside
2. The inner handle has an escape function (retract the latch bolt and the dead bolt at the
same time), and unlock the outer handle
3. The knob can stick out the bolt and lock the outer handle at the same time
Outdoor: 1. The key can be used to unlock under any circumstances
2. When the indoor knob is locked (with the bolt sticking out), the outer handle cannot be
pressed down to unlock
3. When the bolt is retracted, the outer handle can be pressed down to unlock,
Indoor: 1. Under any circumstances, the inner handle can be pressed down to open the door
2. The inner handle has an escape function (retract the latch bolt and the dead bolt at the same
time), and unlock the outer handle
3. The knob can stick out the bolt and lock the outer handle at the same time
Outdoor: 1. The key can be used to unlock under any circumstances
2. When the indoor knob is locked (with the bolt sticking out), the outer handle cannot be
pressed down to unlock
3. When the bolt is retracted, turn the knob up 20° to unlock the outer handle. At this time,
the outer handle can be down.
Press to unlock
Indoor: 1. The door can be opened by pressing the inner handle under any circumstances
2. The inner handle has an escape function (retract the latch bolt and the dead bolt at the
same time)
3. The knob can stick out the bolt and lock the outer handle at the same time
4. When the bolt is retracted, turn the knob 20° to unlock the outer handle
Outdoor: 1. The key can be unlocked at any time
2. The outer handle is always fixed and cannot be pressed down to unlock
Indoor: 1. The inner handle can be pressed down to unlock at any time
42
CERTIFICATE OF COMPLIANCE
Certificate Number 20190510-R39782
Report Reference R39782-20190111
Issue Date 2019-May-10
Bruce Mahrenholz, Director North American Certification Program
UL LLC
Any information and documentation involving UL Mark services are provided on behalf of UL LLC (UL) or any authorized licensee of UL. For questions, please
contact a local UL Customer Service Representative at http://ul.com/aboutul/locations/
Page 1 of 2
Issued to: GUANGDONG KIN LONG PRECISION PRODUCTS CO
LTD
NO.88 Guangfu Rd, Tongle Village,Dongsheng Town
Zhongshan City, Guangdong 528414 CHINA
This certificate confirms that
representative samples of
SINGLE-POINT LOCKS AND LATCHES
See Addendum Page for Models/Product
Have been investigated by UL in accordance with the
Standard(s) indicated on this Certificate.
Standard(s) for Safety: ANSI/UL 10C - Positive Pressure of Fire Tests of Door
Assemblies
Additional Information: See the UL Online Certifications Directory at
https://iq.ulprospector.com for additional information.
This Certificate of Compliance does not provide authorization to apply the UL Mark. Only the UL Follow-Up
Services Procedure provides authorization to apply the UL Mark.
Only those products bearing the UL Mark should be considered as being UL Certified and covered under UL’s
Follow-Up Services.
Look for the UL Certification Mark on the product.
American Standard Lock Certificate
American standard mortise lock ANSI certificate
American standard mortise lock fire certification certificate American standard mortise lock fire certification certificate
UL certificate for American standard mortise lock
43 European standard lock series




