TICAMODULARAIRHANDLINGUNIT TAC/TBC Series
NO.B2822G01
A irPioneer
Establishedin1991,TICAisanationalhigh-techenterprisethatisdedicatedtobecomingtheworld'sleading supplierandserviceproviderofsmartandcleanenvironmentandgreenenergysystems.TiCAisalsoa marketleaderinChinaintermsofcleanairprocessinginextremeenvironments,apractitionerofenergy conservationinbuildingandindustrialenvironments,andapioneerinlow-temperaturepowergenerationand greenandrenewableenergies.TCAownsfiveproductionsitesinNanjing,TianjinGuangzhouChengdu andKualaLumpureightplants,andanetworkofover70salesandserviceoutletsaroundtheworld.
Inthe industrial and biological clean room segment,TicA's market share has achievedover40%inChina.
Servingover70ooGrade-AClass3andClass2hospitals Infectiousospital (Uzbekistan),Alospital(Fiji),rawijayaHospital(doneia)tc.
Serving over5,oooGMP-certified pharmaceutical plants Bayer(Germany),DexaPalembang(Indonesia),MerrymedFarmFactory(Uzbekistan),etc.
Servingover2,0oomicroelectronicmanufacturers WesternDigital (Malaysia),LongshengTechnology(Cambodia),ApexCircuit (Thailand),etc.
AirPioneer
Inventionofframelessfullmoduleairconditioningcabinetstructure China'sfirstISOClass1ultracleanintegratedenvironmentalsystem China'sfirstnationalbrandwithEUROVENT&AHRlcertifications
Great Originality, Fabulous Craftsmanship Over 30 Years' Professional Experience in Clean Air-Conditioning
Design
Application Production Service
Modulardesignwith free
combination
Energy-efficient module with
lowresistance
Focusing on low-carbon energy saving solutions Customization base on personalized demand
International first-class manufacturing production line Intelligent orderdesignsystem
ProfessionalsalesserviceTicare
2017
Obtained MIIT Champion
Product Award
2021
Obtained eco-friendlyzero-ODPinsulation system&TUVcertification
3TICA—
Introduction
Overview
Aftermorethan3OyearsoftechnologicaltransformationforAirPioneerwehaveaccumulatedalotofprojectexperienceand valuablesuggestionsfromcustomersandengineers.Theinnovativemicromoduledesign,leadstoabrand-newcabinetdesign concept,significantly improving the structural flexibility.
Therefore,Airioneerashgherenergysavingpropertyndreliablityeetingtheustomizationneedsofmoreproessional scenarios.
上 AHRICERTIFIED TUV CE 黑SUDCRAA
Casing thickness:sandwich insulation panel 50mm
Installation type:horizontal /vertical /ceiling
Airflowrange:1,000 to360,000m/h
Higher-level Casing Critical industrial Ultra-strong installation performance application adaptability
Professional Design
TICAAir Pioneer modularair handling unit hasa patented casing structureand excellent detaileddesign,aswellasoutstandingperformanceintheindustryintermsofmechanical strength,airtightness,thermal insulationperformance,andanti-coldbridge.(ZL20142 0122442.9) ItalsomeetstheEN1886 standardforcasingperformanceand iscertifiedbyEUROVENT.
Casing inside is flatlyandseamlesslyspliced No corners with possible dust deposition
ObtainedAHRlcertificationforheat exchangerand RoHS certification for copperpipe
High-efficiency heat exchange, high reliability
5 0 {kg } / { m } ^ { 3 } high-density polyurethane Lower heat loss, high strength without deformation
AirPioneer
Self-developedcasing structure
Micromoduledesign
Alabyrinthsealingstructure,withtheconcave andconvexmodulesinterlocked Aluminum-plastic composite profile with soft and hard co-extrusion sealing strip
Full distribution of coilsin theunit section Reduced internal resistance,goodenergy savingproperty
XP
High-efficiencyand energysaving fan
Highest levelofEN1886airtightness Supply cleanairafterfiltering
EC fanwith higher energy efficiency Cleanerwithout voluteand belt dust
Full-size door with largespace,more convenient repair Seamless foaming of door leaf,with good airtightness Pressure relief design for door handle,ensuring operationsafety
Model Selection
Selectunilsgoi-iaieofe i.
Unitdimensionand filtersize
| model | Internal dimensions (H ×W) | External dimensions (H×W)(mm) | Numberoffilters | |||
| mm | TAC | TBC | 24"*24" | 20"*24" | 12"*24" | |
| 012012 | 612*612 | 662*662 | 712*712 | 0 | 0 | 2 |
| 014017 | 714*867 | 764*917 | 814*967 | 0 | 1 | 1 |
| 016023 | 816*1173 | 866*1223 | 916*1273 | 0 | 1 | 2 |
| 020026 | 1020*1326 | 1070*1376 | 1120*1426 | 2 | 0 | 2 |
| 022028 | 1122*1428 | 1172*1478 | 1222*1528 | 2 | 2 | 0 |
| 026031 | 1326*1581 | 1376*1631 | 1426*1681 | 4 | 0 | 2 |
| 028038 | 1428*1938 | 1478*1988 | 1528*2038 | 6 | 0 | 0 |
| 035048 | 1785*2448 | 1835*2498 | 1885*2548 | 8 | 4 | 0 |
| 047063 | 2397*3213 | 2447*3263 | 2497*3313 | 15 | 5 | 0 |
| 050079 | 2550*4029 | 2600*4079 | 2650*4129 | 24 | 0 | 4 |
| 067086 | 3417*4386 | 3467*4436 | 3517*4486 | 35 | 0 | 7 |
| 074102 | 3774*5202 | 3824*5252 | 3874*5302 | 48 | 0 | 6 |
| 096120 | 4896*6120 | 4946*6170 | 4996*6220 | 80 | 0 | 0 |
| 099138 | 5049*7038 | 5099*7088 | 5149*7138 | 88 | 0 | 8 |
| Functionsection | Simplediagram | Dimensions(mm) (referencevalue) L=900,watereliminatorrequired | ||
| Water Mist humidifier | 京京京 | *With standard drain pan: width69 modulus | -- Pipe diameter: DN32 -- Pipe diameter:DN50 -- Pipe diameter: DN50 (2 pcs) | |
| Spray section | L | L=2uble-rowspray nozzel | ||
| Heatrecovery section | *Customizableaccording to thespecificrequirement | |||
| Dehumidification section | *Customizable according to the specific requirement | |||
| Fansection | oto | L=700~3500 | ||
| Diffuser section | 010013-026035:L=500 028034-047058:L=600 047063-050074:L=800 050079-099138:L=1000 | |||
| Silencing section | L=500/800/1100 | |||
| Middle section | 010013-026035:L=500 028034-099138:L=600 *Placed before the filter section,cooling coil section,heating section,silencing section and other function sections | |||
| Air outlet section | 010013-020028:L=500 022028-023033:L=600 026031-035044:L=700 035048-042060:L=900 047055-050069:L=1000 050074-067072:L=1200 067086-074090:L=1400 074102-099138:L=1600 | |||
| Other function sections | Eliminator section | *Shared with cooling coil section | ||
| Evaporation& coolingsection L=900 Self-purification high-efficiency L=1800 cartridge filtersection Inflamer section L=3000 | ||||
Note
Basic Configuration
| System type | Basicfeatures | Sectionconfiguration | |||||||||||
| Commercial unit | Temperaturecontrol applications | Q&& | QQQ | ||||||||||
| ·Applicable to commercial | Mixing section + plate filter section + cooling coil section (/heating section) + fan section | Mixing section + plate filter section + bag filter section + cooling coil section + | fan section | ||||||||||
| Temperaturecontrol applications | ·Apply to 4-pipe commercial | QQ888 Mixing section + plate filter filte ection | |||||||||||
| Constant temperature and humidity unit | ·Temperatureand humidity control ·Applicable to process projects | Mixingsection +platefitersection+coolingcoilsection +heatingsection +humidificationsection +fansection +flowequalization section + bag filter section +air supply section | 。 | 治 | |||||||||
| Constant temperature and humidity with heat recovery unit | Temperature and humidity control aswell as heat recovery ·Applicabletoprocess projects | Mixing section + platefiltersection + bag filter section + DXcooling coi + heatrecoverysection + electric heating section+ humidification section +fan section | |||||||||||
| Full fresh air unit | Focus on freshair humidity treatment Applicable toair- conditioning systems in comfortable projects | External fiter section + cooling coil section + fan section | |||||||||||
Ai irPioneer
Industry Solutions
Taking intoaccountthereal needsof applicationscenariosand summinguptheexperienceinthesubdivisionfields,wehave continuouslyimprovedthedesignofAirPioneeraccordingtothe scenariosandarecommittedtoprovidinguserswithextremelyclean andrefinedenergy-savingscenarioapplicationsolutions.
Applicationfeatures
Hygiene requirements forairsupply: 5\~75cfu/m³ bacterial concentration ISO 5\~8.5 cleanliness
Frequent cleaningand disinfection insidethe equipment
Lowhumidityinspecial operatingdepartment, requiring energy consumption for reheating
Productfeatures
·ProfessionalaibacterialoigurationschasoadspectrumifiencyUCsilronntbacterialfieddust free fan
Stainlesssteelinnerplateissuitable forfrequentdisinfectionandiseasytoclean,splicing is smooth
·The DXunitcanprovidelow-humidityairsupplyandpreciseheatrecovery,therebyguaranteeing theperformanceof the energy-saving systemwith temperature and humidity control typically used in hospitals.
\* Some functions are optional. Consult TICA factory for detailed configuration.
Biopharmaceutical workshops
Applicationfeatures
Comply with GMP whole-process supervision
Microbial contamination isstrictly controlled in the production process
Theairtightnessof HEPA meetstheGMPcleanliness requirements
Productfeatures
·WiththepatentedsealedHEPAmountingframe(Z0152O338421.5),theairsupplycleanlinessafterHEPAreachesISOClass5 ·Ozonesterilizationisusedwithavariableairflowfantoachievedisinfectionmodeswitching,meetingGMP/FDArequirements : 2 0 + largeair-conditioning testing laboratoriesaccreditedbyCNAS&ILACMRA;
·Mature FAT testing solutions
LargeairflowMAUforSemiconductorfactories
Applicationfeatures
APC and AMC pollutants are strictly controlled
Thedemand forfreshairis complexandchangeable
Largeair flowandhigh air pressure freshairdevicesare equipped
Productfeatures
Primarymediumandhighefciencyfilters,aswellasatersprayfiterandchemicalfilterareconfguredforpurifcationin electronics plants.
·Themulti-stagehigh-eficiencyheatexchangersuitableforlargeloadoffreshaircancopewithcomplexandchangeable working conditions and meet indoor constant temperature and humidity requirements.
·High-strength MAU box ensures no deformation under largeair flowand large static pressure.
\*Some functions are optional. Consult TiCA factory for detailed configuration.
Arrangementof full freshairMAUfunctionsectioninelectronicsplant
Air inlet ^ + primaryand medium efficiency ^ + preheating ^ + middlesection ^ + pre-cooling ^ + middlesection ^ + waterspray ^ + middle section ^ + re-cooling ^ + middle section ^ + reheating ^ + fan ^ + flowequalization ^ + two-stagechemical ^ + middle section ^ + mediumefficiency ^ + highefficiency ^ + airoutlet
Mainparameterestimationtablefortypicalapplications
| Air flhw | ESa) | Motorwower | Preco | Re-c | (LnitwixH)(m) | ||
| 40000 | 800 | 45 | 550 | 340 | 610 | 105 | 12900×3007×2085 |
| 45000 | 800 | 55 | 610 | 380 | 700 | 115 | 12900×2854×2442 |
| 50000 | 800 | 75 | 685 | 425 | 770 | 130 | 12900×3160×2442 |
| 55000 | 800 | 75 | 750 | 467 | 850 | 145 | 13900×2905×2697 |
| 60000 | 800 | 75 | 810 | 500 | 920 | 155 | 14000×3313×2697 |
| 70000 | 800 | 90 | 950 | 590 | 1080 | 180 | 14000×3619×2850 |
| 80000 | 800 | 90 | 1090 | 680 | 1240 | 205 | 14000×3874×2850 |
| 100000 | 800 | 110 | 1370 | 850 | 1550 | 260 | 15200×3772×3717 |
| 120000 | 800 | 132 | 1630 | 1010 | 1850 | 310 | 15200×4486×3717 |
| 140000 | 800 | 160 | 1900 | 1150 | 2100 | 360 | 15400×4690×4074 |
| 180000 | 800 | 200 | 2450 | 1520 | 2750 | 450 | 15400×5098×4686 |
Notes:1.Theabove isa fulfreshair unit fora chipplant.For other solutions,consult TICA factory. 2.ThemotorpoweristeestimatedalueofthereseredmarginThecurentmotorpowerisbasedontheresistancebroughtbytefinalstage H13 high efficiency fiter. 3.Theunitsizeisanetimatedvaluendthespaceofthemachineroomshoudbenosmalerthantherequiedsize.Forfurthdimsion selection of the unit, consult TICA factory. 4.The air inlet conditions in cooling season and heating season are 3 8 ^ { \circ } C 1 6 0 % and - 6 ^ { \circ } C 1 5 0 % ,respectively. 5.The inlet and outlet temperatures of cold water are \bar { 1 4 } / 2 0 ^ { \circ } { C } (pre-cooling) and 7 / 1 3 ^ { \circ } { C } (re-cooling),respectivelyandthe inletandoutlet temperatures of hot water are both 3 8 / 3 2 ^ { \circ } C 6.The recommended principle forsize selection is that the windwardfanspeedof thecoil does not exceed 2.5m/s.
TICARE
Customized service
Asaprofessionalcleanprocesingsystemintegratorandserviceproviderweprovideairtreatmentdesignandprodctcustom izationservicesthatftheusers'businessformatforvariousextremeindustrialenvironmentsandcomfortablelivingenvironments,fullyoveringcommonneeds.Wearecommitedtoprovidinguserswiththeotimalleanevironmentsolutions.
Personalizedcustomizationand quickmodelselection
Specializedoperatingsystem, automaticassociationdesign,quick andaccuratemodelselection,perfect projectmanagement,andquick feedbackoncustomerneeds.
Modelselectionfunctions
Avarietyofstandardizedmodules, directlyprovidingmodelsforselection; Avarietyoffunctionsection configurations,meetingrequirements forprocessdesign; Alarge-capacitymodeldatabase,coping withvariousscenariorequirements.
Professionalmodelselection software
Theheatexchangermodelselection softwarepassesAHRlcertification. Thewholemodel selectionsoftware passes.
Euroventcertification.
Outputofprofessionalmodelselectionreports
Themodelselectionresultscanbeoutputthroughacomplete setofreports,includingthe technical parameterdetail listofeach functionsectionoftheunit,thecoilmodelselectiondetaillist, enthalpy/humiditychart,operatingconditions,fancurve,weight reportandunitdimensiondiagram.
Air Pioneer
Core Components
AirPioneer'skeycomponents,areallselectedfromwell-known brands.bringingusersareliableandconvenientexperience.
Component
Core Components
Fansection
Intelligent selectionofoptimal model,speed,and motor
·The fanimpellerandbelt pulleyarecorrectedbystaticand dynamic balance before delivery,and operate stably.
·Adampingdevice isequipped to greatly reduce the operating noise.
·Theimpellerand framearemadeof high-strengthalloysteel plate,with high structural strength.
·Avarietyof inverter fansareavailable.
Centrifugalfan
·Double inlet forward/backward ·Belt-driven,with good aerodynamic performance ·Variable speed motor is optional
Plug fan
·Direct-drive,easytoclean, small vibration,and low noise ·Variablespeedmotor is optional
Coil section
·Allcoilswillundergoapressuretestbeforedeliverytoensureworry-free operation.
·Zigzag-shapedcircuitcaneffectivelypreventtheproblemoffreezingcracks duetouncompleted drainage inwinter.
·All finsare made of hydrophilicaluminum foil to improve heat exchange efficiencyandanti-oxidationeffect.
·Thedrainpanis V-shapedwithaninclinationangleofover 5 ^ { \circ } toensure rapid drainage.
·Withavarietyofcircuit formsandAHRl-certifiedprofessional selection software,thewaterresistancecanbeflexiblyoptimized.
Cold/hotwatercoil
· High-quality copper pipes and hydrophilic aluminum fins ·Adoptionof integrated mechanical expansion pipe
·Excellentcavitationresistanceand waterhammerresistance ·Optional aluminum fins/steel fins
Filtersection
·Micro modular design of imperial units,with full distribution of filters in the unit height direction
·Uniformair flow,reducing theaverageairspeedof the sectionand improving the filtration efficiency
·Airtight installationandoverhaul frame,ensuring low leakagerate and convenientoverhaul
四
Platefilter
Filtration efficiency: MERV7-MERV9
Bag filter Filtration efficiency: MERV7-MERV13
HEPAfilter Filtration efficiency: E10-E12/H13-H14
Anti-bacterialfiltersection
Therequirementofhealthyventilationinpublicplacescanbe metbytheoptionalantibacterialfiltersection:
·Itisrecommendedtochooseamediafilterwithsilverionsto preventsecondarypollution frombacterial reproduction. ·Ahigh-voltageelectrostaticsterilizationfilterisequippedto captureparticulatematterandkillmicroorganisms. ·Photocatalystdegradestoxicandharmfulgasesintheair, effectivelykillingavarietyofbacteria.
Anti-bacterialfilter
·MeltblownPPpluschemical ion coating
Plate typeelectrostatic
·Microorganismsare killed through high pressure ionizationand adsorption.
Core Components
Heat recovery
·Modern air conditioning increasingly uses heat recovery systems. ●Itnot only directly saves operating costs,butalso indirectly playsa role in ecological protection.
Humidification section
Humidificationisanessential functionin orderto provide healthy air with the right humidity.
The following performance should beconsidered whenchoosing ahumidifier:
·Saturated efficiency ·Humidificationcleanliness ·Control precision ·Absorptiondistance
AirPioneer
Reference Projects
Reference Projects
Hotel&Commercial Building
The Park Semarang
Holiday Inn Bandung
University
Mangosuthu Unviersity of Technology
Industrial Cooling
Proton Automobile
Semi-Conductor Factory
T&W Electronics
25 TICA—




