Specifications
High static pressure duct
| Model (TMDH-XX-AB) | 100 | 112 | 125 | 140 | ||||||
| Nominal cooling capacity | kW | 10.0 | 11.2 | 12.5 | 14.0 | |||||
| Nominal heating capacity | kw | 11.2 | 12.5 | 14.0 | 16.0 | |||||
| Power supply | V/N/Hz | 220/1/50 | ||||||||
| Motor type | , AC motor | |||||||||
| Nominal input power | W | 400 420 | 500 | 550 | ||||||
| Dimensions(WxDxH) | mm | 1200×750×390 | ||||||||
| Air flow | High medium | 1800 2000 | 2250 | 2700 | ||||||
| m³/h 1450 | 1800 | 2150 | ||||||||
| 1050 | 1300 | 1450 | ||||||||
| Low ESP (adjustable) | Pa | 50(100/200) | 50(100/200) 50(100/200) | 1750 50(100/200) | ||||||
| Sound pressure level (H/M/L) | dB(A) | 49/46/42 | 49/46/42 51/47/43 | 51/47/43 | ||||||
| Weight | kg | 62 | 62 | 62 | 62 | |||||
| Coninectingige | Liquid pipe | mm | Φ9.52 | |||||||
| Gas pipe | mm | Φ15.88 | ||||||||
| Condensate drain pipe mm | DN25 | |||||||||
| Model (TMDH-XX-BI) | 200 | 250 | 335 | 400 | 450 | 500 | 560 | 615 | ||
| Nominal cooling capacity | kW | 20.0 | 25.0 | 33.5 | 40.0 | 45.0 | 50.0 | 56.0 | 61.5 | |
| Nominalheatingcapacity | kw | 22.4 | 27.0 | 37.5 | 45.0 50.0 | 56.0 | 63.0 | 69.0 | ||
| Power supply | 380/3/50 | |||||||||
| Motor type | V/N/Hz 。 | AC motor | ||||||||
| Nominal input power | W | 1100 | 1100 | 2200 2200 | 3000 | 3000 | 3000 | 3000 | ||
| Dimensions (WxDxH) | mm | 906×1410×590 | 1006×2360×840 | |||||||
| Air flow | m2/h | 4000 | 7000 7000 | 1006×1860×800 9000 | 10000 | 10000 | ||||
| esp | Pa | 4000 100/200 | 100/200 | 100/180/250 | 100/180/250 | 100/180/250 | 9000 100/180/250 | 200/300 | 200/300 | |
| Sound pressure level | dB(A) | 54 | 54 | 55 | 55 | 57 | 57 | 59 | 59 | |
| Weight | kg | 100 | 100 | 200 | 200 | 200 | 200 | 260 | 260 | |
| Conimetingpnipe | Liquid pipe mm | 12.7 | 15.88 | 19.05 | ||||||
| Gas pipe | φ22.23 | |||||||||
| mm | Φ28.6 | 31.8 | ||||||||
| Condnpipate | mm | |||||||||
| DN32 | ||||||||||
COMFORT
Quiet Operation
3rand-new highly eficient noise reduction motor built with the latest technology minimizing the noise of IDU.
HEALTH
Wideair flow
Theuniquetwo-layeredauto swing providing widerairsupplyrange tooptimizeairfow compared toconventional units
EASYMAINTENANCE
Removableairreturnpanel
The removableair return outlet panel facilitates the cleaning of filterand panel.
Specifications
Wall-mounted
| Model (TMVW-XX-ACB) | 028 | 036 | 040 | 056 | |||
| Nominal cooling capacity | kW | 2.8 | 3.6 | 4.0 | 5.6 | ||
| Nominal heating capacity | kw | 3.0 | 4.3 | 4.5 | 6.0 | ||
| Power supply | V/N/Hz | 220/1/50 | |||||
| Motor type | - | DC motor | |||||
| Nominal input power | W | 65 65 70 | 70 | ||||
| Dimensions (WxDxH) | mm | 803×209×287 | 913×209×287 | ||||
| Air flow | High | m/h | 600 | 600 | 600 | 750 | |
| medium | 550 | 550 | 550 | 700 | |||
| Low | 500 | 500 | 500 | 650 | |||
| Sound pressure level (H/M/L) | dB(A) | 40/36/32 | 45/41/35 | ||||
| Weight | kg | 12 | 12 | 12 | 13 | ||
| Connetingnige | Liquid pipe | mm | Φ9.52 | φ9.52 | |||
| Gas pipe | mm | φ15.88 | 22.23 | ||||
| Condensate drain pipe | mm | DN20 | |||||
Celling&Floor
COMFORT
HEALTH
Quiet Operation
Unequally spaced oblique angle large diameter through flowfan isusedto ensurestrongairsupply,lower fan speedand lowerenergyconsumption.
Health
Anefficientfilterdeviceisequippedtocompletelyfilter dust,smokeand other smallparticles in theair,effectively preventing bacteria breedingand thoroughly improving the air quality.
AIRFLOW
Wideair flow
Autowide-rangeairsupplyguaranteed gentle,natural,and evenair flow.Variousair supply modesareavailable. Anti-cold wind designensuresmore comfortableair supply in winter.
EASYMAINTENANCE
Removableairreturnpanel
The removableairreturnoutlet panel facilitates the cleaningof filterand panel.
Single-sidemaintenance
All maintenanceworkand theremoval of fanand motor canbe implemented through theaccess hole on the side.
Specifications
Ceiling &Floor
| Model(TMVX-XX-A) | 028 | 036 | 056 | 071 | 090 | 112 | 125 | 140 | |||
| Nominal cooling capacity | kW | 2.8 | 3.6 | 5.6 | 7.1 | 9.0 | 11.2 | 12.5 | 14.0 | ||
| Nominal heatingcapacity | kW | 3.2 4.0 | 6.3 | 8.0 | 10.0 | 12.5 | 14.0 | 16.0 | |||
| Power supply | V/N/Hz | 220/1/50 | |||||||||
| Motor type | ACmotor | ||||||||||
| Nominal input power | W | 48 62 85 | 120 156 | 210 | 240 | 240 | |||||
| Dimensions(WxDxH) | mm | 905×673×243 | 1288×673×243 | 1672×673×243 | |||||||
| Air flow | High | m³/h | 450 | 600 | 820 | 1100 | 1470 | 1800 | 2000 | 2000 | |
| medium | 360 | 480 | 700 | 980 | 1280 | 1550 | 1680 | 1680 | |||
| Low | 280 | 370 | 570 | 850 | 1060 | 1250 | 1350 | 1350 | |||
| Sound pressure level (H/M/L) | dB(A) | 42/39/36 | 43/40/38 | 45/42/40 | 47/44/41 | 49/46/42 | 50/47/44 | 51/48/45 | 51/48/45 | ||
| Weight | kg | 28 | 28 | 30 | 40 | 40 | 45 | 45 | 45 | ||
| Connecting pipe Dimensions | Liquid pipe | mm | 6.35 | 9.52 | |||||||
| Gas pipe | mm | Φ12.70 15.88 | |||||||||
| Condensatedrain pipe | mm | DN25 | |||||||||
Full-freshairhandlingunit
HEALTH
Intake freshair
Intakefreshair tomaketheoutdoorairclose toroom temperature throughtheindoor heatexchangerandthe powerful heating/cooling capacity,so as to meet various requirements.
AIRFLOW
Multi-split unit for multi-point air supply
Air outlets can be flexibly configured to meet the requirements for multi-point air supply.
300Paultra-high static pressure
Allfreshair handlingunithas thestaticpressureup to 3 0 0 \mathsf { P a } ,makingitpossibletoconnectextra-longairducttorealize longdistanceairsupplyandbring freshand cleanair to indoor places.
Specifications
Full-freshairhandlingunit
| Model (TMDF) | 120A-020 | 175A- | 210A- | 250A- | 250A- | 250A- | 300A- | 400A- | 400A- 500A- | 500A- | 600A- | 600A- | |||
| Nominal cooling capacity | kW | 14.0 | 25.0 | 28.0 | 28.0 | 28.0 | 28.0 | 28.0 | 45.0 | 45.0 | 56.0 | 56.0 | 56.0 56.0 | ||
| Nominal heatingcapacity | kw | 10.0 | 14.0 | 17.4 | 17.4 | 17.4 | 17.4 17.4 | 28.0 | 28.0 | 35.0 | 35.0 | 35.0 | 35.0 | ||
| Power supply | V/N/Hz | 220/1/50 | 380/3/50 | ||||||||||||
| Motor type | acmotor | ||||||||||||||
| Nominal input power | W | 330 | 630 700 | 480 | 560 | 790 | 750 | 880 | 1290 | 1000 1400 | 1350 | 1700 | |||
| Dimensions (WxDxH) | mm | 1200×750×390 | 1300×820×500 | 1650×850×665 | 2000×850×665 | ||||||||||
| Air flow | m³/h | 1200 | 1750 | 2100 | 2500 | 2500 2500 | 3000 | 4000 | 4000 | 5000 | 5000 | 6000 | 6000 | ||
| EsP | Pa | 200 | 220 | 200 | 150 | 200 | 300 | 200 | 200 | 300 200 | 300 | 200 | 300 | ||
| Sound pressure level | dB(A) | 49 | 49 | 49 | 52 55 | 58 | 56 | 59 | 62 | 62 | 65 | 62 | 65 | ||
| Weight | kg | 62 | 75 | 75 | 75 75 | 75 | 75 | 140 | 140 | 165 | 165 165 | 165 | |||
| Connecting pipe Dimensions | Liquid pipe | mm | 9.52 | φ12.70 | 15.88 | ||||||||||
| Gas pipe | mm | Φ15.88 Φ22.23 | 25.58 | 28.58 | |||||||||||
| Conde psate | mm | DN25 | |||||||||||||
S
Fresh Air Solutions Care for every breath
97% PM2.5 purification efficiency \*1
90% Formaldehyde purification efficiency \*2
S
O
7
Freshair introduction
EfficientPM2.5
Chemicalremovalof formaldehyde
HeatRecovery Ventilator (HRV)
++=益 Ventilationand Heat Haze airexchange recovery removal
Multiplehazeremoval
Must-haveforhazeremoval
·Filtering offers layers of protection. ·Themaximum PM2.5 removal rate is 9 5 %
Highlyefficient energyrecovery
Efficient heat exchange core
·The heat recovery core is formed by cross-laminating androtating the single-sided corrugated,parallel papersheets by 9 0 ^ { \circ } ,withtwomutuallyvertical and non-interfering channels.The freshairand return airareable to exchange heatand humiditywithout being mixed when passing the two channels.
·With the latest technologyof Japan,the parallel paperisevenand tight,andboastsa heatrecovery rateof 8 0 %
Omni-directionalairreplacement
Fresh air enjoyed without opening the window
Theunit is ceiling-mounted in places not that noisesentimental.Withallairportsput indoors,itcanensure thatair issuppliedand discharged evenlyand smoothly.
Specifications
| Model (TRV-XX) | 015 | 025 | 035 一 | 050 | |
| Powersupply | V/N/Hz | 220/1/50 | |||
| Power Input | W | 105 | 135 | 276 | 365/380 |
| Current | A | 0.5 | 0.6 | 1.25 | 1.7/1.76 |
| Air flowrate | m³/h | 150 | 250 | 350 | 500 |
| Purification efficiency | % | 95 | 95 | 95 | 95 |
| ESP | Pa | 80 | 80 | 80 | 50/100 |
| Heatexchangeefficiency (heating/cooling) | % | 85/67 | 82/63 | 80/62 | 73/61 |
| Enthalpyexchangeeficiency (heating/cooling) | % | 75/55 | 72/52 | 68/51 | 64/50 |
| Sound pressure level | dB(A) | 32 | 34 | 39 | 43 |
| Weight | kg | 24 | 24 884×555×230 | 27 | 53 950×972×314 |
| Dimension | mm | ||||
Standardseriesfreshairventilators
Patentstructureandlowairleakagerate Elimination ofcoldbridgeand rust
The junction part of the unituses aluminum profile with a concave grooveandaconvex grooveand issecuredwithbolts andnutsto formapatentedlabyrinthsealingstructure,achieving theairleakagerateas lowas 0 . 0 2 9 % -only1/66oftheair leakagerateallowedinthenationalstandardandrealizinglower operating costs.
Allthemetal partsin thecabinetofTlCA'shigh-capacityduct IDUare isolated from outsidemetal parts usingpolyurethane foamandspeciallydesignedsealingstrips,avoidingthe thermal insulationstripsattached insidethecommonproducttoprevent condensation.Coldbridgeanddrippingare resolved,and the systemnoiseislower.
Highefficiencyandenergysaving
Safeandreliable
Thefull core heat exchanger achieves high heat exchange efficiency,temperatureefficiencyashighas 7 0 % and enthalpy efficiencyashighas 60 % #
The direct driven fan does not require maintenance.Only the filterneeds to be cleaned regularly.
Specification
| Model (TFD-XX) | 010FC | 015FC | 020FC | 025FC | 030FC | 040FC | 050FH | 060FH | 080FH | 105FH | |||||
| Air flow | m³/h | 1000 | 1500 | 2000 | 2500 | 3000 | 4000 | 5000 | 6000 | 8000 | 10500 | ||||
| EsP | Airsupply | Pa | 90 | 110 | 120 | 110 | 100 | 110 | 100 | 100 | 110 | 100 | |||
| Air discharge | Pa | 90 | 110 | 120 | 110 | 100 | 110 | 100 | 100 | 110 | 100 | ||||
| Cooling | %% | 6152 | 5951 | 5750 | 5750 | ||||||||||
| 5951 | 6153 | 5850 | 5951 | 5750 | 5750 | ||||||||||
| Heating | Temperaturerecoveryefficiency | % | 72 | 71 | 73 | 70 | 71 | 69 | 69 | 71 | 69 | 69 | |||
| Enthalpyrecoveryrate | % | 60 | 59 | 61 | 58 | 59 | 58 | 58 | 59 | 58 | 58 | ||||
| Motor power | |||||||||||||||
| Aisgarge | WW | 03 | 0.45 | 0.55 | 0.55 | 11 | 1515 | 0.552 | 1.02 | 1.50x2 | |||||
| Sound pressure level Power supply | dB(A) | 53 | 53 | 55 | 56 | 58 | 59 | 62 | 62 | 63 | 66 | ||||
| V/N/Hz | 220/1/50 | 380/3/50 | |||||||||||||
High-endseriesfreshairventilators
Wideapplication
Wideairflowrange:1000m/h\~6000m³/h
Modelmodels:Two-wayventilationandenergyrecovery
Applytooccasionssuchasresidences,meetingrooms,labs,offices, equipment rooms,restaurantsand gyms.
High reliability
Easyinstallation
Structural design:The product isdesignedwithasheetmetal structure,with insulation cotton attached inside.
Convenient installation: The machine is positioned in the ceiling and does not occupy the indoor effective space.
| Model (TRD-XX) | 100 | 150 | 200 | 250 | 300 | 400 | 500 | 600 | ||
| Fresh air flow | m/h | 1000 | 1500 | 2000 | 2500 | 3000 | 4000 | 5000 | 6000 | |
| ESP | Pa | 120 | 160 | 105 | 100 | 150 | 125 | 95 | 120 | |
| Enthalpy recovery rate | 5122 | 5160 | 5162 | 5871 | 5165 | 577 | ||||
| Cooing | %% | 5167 | 587 | |||||||
| TemperaturerecoveryeffciencyHeating | Cooling | % | 67 | 61 | 61 | 64 | 64 | 67 | 67 | 67 |
| % | 82 | 77 | 75 | 80 | 82 | 78 | 82 | 84 | ||
| Sound pressure level | dB(A) | 45 | 51 | 52 | 53 | 52 | 58 | 59 | 60 | |
| Input power of the entire unit | W | 550 | 920 | 1310 | 1630 | 1900 | 1940 | 2790 | 3280 | |
| Current of the entireunit | A | 2.7 | 4.2 | 6.3 | 7.6 | 8.7 | 5.3 | 7.3 | 7.8 | |
| Powersupply | V/N/Hz | 220/1/50 | 380/3/50 | |||||||
| NetWeight | Kg | 100 | 143 | 175 | 185 | 198 | 290 | 360 | 390 | |
TIMS HYplus Healthy VRF
Quadruple Filtration √ Physical intercept Chemicalaldehyderemoval 欢 Silverionbacteriostasis 河 UVCdisinfection
Healthy Air Is On the Way
BasicBenefitsofHealthyAir
Reduce Iliness AlleviateAllergies Pet-Friendly Sleep Better
QuadrupleFiltration
Creatinghealthylife
Usechemical formaldehyderemoval filtersandtheefficicncyisupto 9 5 % ina 3 0 ~ \mathsf { m } ^ { 3 } labmodule.
Returnto safe envirnoment
UseArgenzil and UvC to sterilizeand inactivate. Thesterilization efficiency of { \mathsf { A } } { \mathsf { g } } ^ { + } is600oo times that of alcohol. UVC light can denature and dissociate protein. The primary purification efficiency of microbe isup to 90 % 业
Scene customization
PurifyModuleMatchingTable
| Type | Model | Capacity(kW) | ||||||||||||||||||
| 2.2 2.5 | 2.8 | 3.2 | 3.6 | 4.0 | 4.5 | 5.0 | 5.6 | 6.3 | 7.1 | 8.0 | 9.0 | 10.011.212.5 | 14.0 | 16.0 | ||||||
| Hyplus-Ultra-thin PurificationType(TP03) | TMDP | · | · | · | · | · | · | · | · | · | · | · | ||||||||
| Hyplus-MedicalSpecialType(TP04) | TMDP | · | · | · | · | · | · | customize | customize | |||||||||||
| Hyplus-MicroelectrostaticType(TP05)* | TMDP | · | · | · | ||||||||||||||||
| Hyplus-Quadruple Filtration Type (TP06) | TMDP | . | · | · | · | · | · | · | · | · | · | · | · | · | · | · | · | · | · | |
HYplus IDU
| 025 | ||||||||||||||
| ModTl TMAP-ACANNN | 022 2.2 | 2.5 | 028 2.8 | 032 3.2 | 036 3.6 | 040 4.0 | 045 | 050 | 056 | 063 | 071 | |||
| Nominal cooling capacity | kW | 2.5 | 2.8 | 3.2 | 3.6 | 4.0 | 4.5 | 4.5 5.0 | 5.0 5.6 | 5.6 6.3 | 6.3 7.1 | 7.1 | ||
| Nominal heatingcapacity | kW | 8.0 | ||||||||||||
| Power supply | V/N/Hz | 220/1/50 AC motor | ||||||||||||
| Motor type | W | 55 | 105 | |||||||||||
| Nominal input power Dimensions(WxDxH) | mm | 54 54 54 | 77 77 920×450×200 | 77 100 | ||||||||||
| Air flow | High | 500 | 500 | 500 | 700×450×200 560 | 560 | 560 | 750 | 750 | 750 | 920 | 1140×450×200 1000 | ||
| Medium | m³/h | 370 | 370 | 370 | 430 | 430 | 430 | 620 | 620 | 620 | 710 | 800 | ||
| Low | 310 | 310 | 310 | 360 | 360 | 360 | 550 | 550 | 550 | 590 | 680 | |||
| ESP (adjustable) | Pa | 10(30) | ||||||||||||
| Sound pressure level (H/M/L) | dB(A) | 33/28/23 33/28/23 | 33/28/23 | 33/28/24 | 33/28/24 | 33/28/24 | 35/30/28 | 35/30/28 | 35/30/28 | 36/32/28 | 37/32/29 | |||
| Weight | kg | 17.5 17.5 17.5 17.5 | 21.5 | 21.5 | 28 | 28 | ||||||||
| Conecting | Liquid pipe | mm | 17.5 17.5 21.5 6.35 | 9.52 | ||||||||||
| mm | 9.52 | 12.70 | ||||||||||||
| Gaspipe Condepsate | mm | 15.88 | ||||||||||||
| Dimensions | mm | DN25 18.5×700×200 | 18.5×920×200 | |||||||||||
| Dimension offilter | 18.5×1140×200 | |||||||||||||
| ModTlTMDC-ACBNNN | 022 | 025 | 028 | 032 | 036 | 040 | 045 | 050 | 056 | 063 | 071 | |||
| Nominal cooling capacity | kW | 2.2 | 2.5 | 2.8 | 3.2 | 3.6 | 4.0 | 4.5 | 5.0 | 5.6 | 6.3 | 7.1 | ||
| Nominal heatingcapacity | kw | 2.5 | 2.8 | 3.2 | 3.6 | 4.0 | 4.5 | 5.0 | 5.6 | 6.3 | 7.1 | 8.0 | ||
| Powersupply | V/N/Hz | 220/1/50 | ||||||||||||
| Motor type | - | DCmotor | ||||||||||||
| Nominal input power | W | 50 | ||||||||||||
| Dimensions (WxDxH) | mm | 40 | 40 | 40 700×450×200 | 45 | 45 | 50 | 50 | 50 | 60 | 60 | |||
| High | 500 500 | 560 750 | 920×450×200 750 | 750 | 1140×450×200 1000 | |||||||||
| Air flow | Medium | m³/h | 370 | 370 | 500 370 | 560 430 | 430 | 620 | 620 | 750 620 | 620 | 920 710 | 800 | |
| 310 310 | 310 | 360 | 360 | 550 | 550 | 550 | 550 | 590 | 680 | |||||
| Low ESP (adjustable) | Pa dB(A) | 10(30) | ||||||||||||
HYplus IDU
| ModelTMPP-AEBNNN | 022 | 025 | 028 | 032 | 036 | 040 | 045 | 050 | 056 | |||
| Nominal cooling capacity | kW 2.2 | 2.5 | 2.8 | 3.2 | 3.6 | 4.0 | 4.5 | 5.0 | 5.6 | |||
| Nominal heatingcapacity | kW 2.5 | 2.8 | 3.2 | 3.6 | 4.0 | 4.5 | 5.0 | 5.6 | 6.3 | |||
| Power supply V/N/Hz | 220/1/50 | |||||||||||
| Motor type | - | DCmotor | ||||||||||
| Nominal input power | W | 35 35 35 | 45 | 45 | 45 | |||||||
| Dimensions (WxDxH) | mm | 40 920×450×200 | 40 | 40 | 1140×450×200 | |||||||
| Air flow | High | m³/h | 450 | 450 | 450 | 500 | 500 | 500 | 650 | 650 | 650 | |
| ESP (adjustable) | Pa | 10(0~30) | ||||||||||
| Sound pressure leve (CH/M | dB(A) | 33/28/23 | 33/28/24 | 35/30/28 | ||||||||
| Weight | kg | 21.5 | 26.5 | |||||||||
| Connecting pipe Dimensions | Liquid pipe | mm | ||||||||||
| Gaspipe | mm | 6.35 Φ12.70 | ||||||||||
| Condepsate | mm | DN25 | ||||||||||
| Dimensionof filter | mm | 42×920×200 | 42×1140×200 | |||||||||
| Dimensionoffilter | mm | 42×920×200 | 42×1140×200 | |||||||
| Mode1TMPP-AEBNN | 071 | 080 | 090 | 100 | 112 | 125 | 140 | 160 | ||
| Nominal cooling capacity | kW | 7.1 | 8.0 | 9.0 | 10.0 | 11.2 | 12.5 | 14.0 | 16.0 | |
| Nominal heatingcapacity | kW | 8.0 | 9.0 | 10.0 | 11.2 | 12.5 | 14.0 | 16.0 | 18.0 | |
| Powersupply | V/N/Hz | 220/1/50 | ||||||||
| Motor type | - | DCmotor | ||||||||
| Nominal input power | W | 100 130 130 | 160 160 | 160 | 200 | 200 | ||||
| Dimensions (WxDxH) | mm | 1200×680×270 | ||||||||
| Air flow High | m³/h | 1000 1300 | 1300 | 1600 | 1600 | 1600 | 2000 | 2000 | ||
| ESP (adjustable) | Pa | 10(0~50) | ||||||||
| Sound presure level(HA/M/ | dB(A) | 37/32/29 | 40/36/33 | 40/36/33 | 43/37/33 43/37/33 | 43/37/33 | 43/35/27 | 43/35/27 | ||
| Weight Liquid pipe | kg | 34.5 34.5 34.5 37 37 37 | 38 38 | |||||||
| Connecting | mm | φ9.52 | ||||||||
| pipe | Gas pipe | mm | 15.88 | |||||||
| Dimensions Corndepsate | mm | DN25 | ||||||||
| Dimension offilter mm | 150×1200×270 | |||||||||
| Model TMDP-TP04 Nominal coolingcapacity | 10.0 | 11.2 | 12.5 | 071AEBNNN 080AEBNNN 090AEBNNN 100AEBNNN 112AEBNNN 125AEBNNN 140AEBNNN 160AEBNNN 14.0 | ||||||
| Nominal heatingcapacity | kW | 7.1 8.0 | 8.0 9.0 | 9.0 10.0 | 11.2 | 12.5 | 14.0 16.0 | 16.0 18.0 | ||
| kW V/N/Hz | ||||||||||
| Powersupply | - | 220/1/50 | ||||||||
| Motor type | W | DCmotor | ||||||||
| Nominal input power | mm | 100 | 130 | 130 160 | 160 1200×680×270 | 160 | 200 | 200 | ||
| Dimensions(WxDxH) Air flow | High | m³/h | 1000 1600 1600 1600 2000 | |||||||
| Pa | 1300 1300 10(0~50) | |||||||||
| ESP (adjustable) | dB(A) | |||||||||
| Sound pressure level (H/M/L) | kg | 37/32/29 40/36/33 | 40/36/33 | 43/37/33 | 43/37/33 37 | 43/37/33 | 43/35/27 | 43/35/27 | ||
| Weight | 34.5 34.5 | 34.5 | 37 | 9.52 | 37 | 38 | 38 | |||
| Connecting pipe Dimensions | Liquid pipe | mm | ||||||||
| Gaspipe | mm | 15.88 | ||||||||
| Condensate drainpipe | mm | DN25 | ||||||||
| Dimension of filter | mm | 150×1200×270 | ||||||||
Intelligent Control
Provide you with convenient services
WirelessRemoteController
ModeSetting:Cool/Heat/Dry/Fan/Auto
Scheduled power-on/off
Temperature setting
Fanspeed setting:High/Medium/Low/Auto
Eco/Quiet/Sleep functions
Vertical swing/Horizontal swing
TMC311
Wired Remote Controllers
8 6 x 8 6mm panel,LED
Error reporting
ON/OFF,swing,memory function,etc. Cool/Heat/Auto/Fan/Drymodes
Temperature setting,timer power-on/-off Touch keys
Filter cleaning reminder
Background light TICA √
24.0℃
02:34
鸟 ¥ △
品 ? V
TMC315/TE300
Central Controllers
8-inch colored touchscreen
Supports centralized control of amaximumof 64 IDUs in8systems
Setting,management and monitoring (set temperature,air flow) of IDU Accessibleto IDU/ODUnetwork
Schedul control byweek/month/year
Unified management of IDU groups
Statistics of changes inrunning statusesof all devices inacertain time period. Faultdisplay,parameterstatus query,device query,and permission
management
Display of indoor environmental indicators (IDU needs to be equipped with sensor nodes)
OCPAD
Building Management System (BMS)
TIMSadoptsmultipleBMSstoaccesstotheBAS for comprehensivelyauto control. TICA BMS supportsaccess via ModBus.Up to 1024IDUsand16ODUscanbeconnected.
Basiccontrol functions
\bullet ACon/off,operation,and monitoring the operationstatus
{ \otimes } Monitoring the IDU error code
\bullet Monitoringand setting the IDU temperature
\bullet Monitoring and switching the operating mode
\bullet Remote controller lock function
\bullet Service monitoring
\bullet Auto running
\bullet Mode lock function,user can lock the running mode of indoorunit
\bullet Free management by group
⊚ Complete schedule management
① Historical data records
{ 1 2 } Schedule control by week/month/year
⊚ Centralized control function
⊚ Interlock control (fire alarm,door lock,fault,etc.)
Intelligentsoftware
Selectionsoftware
TICAdedicated toprovidethebestHVACengineeringsupportandsolutions focusedoneffectivelydesigned,built, supervisedandmntainedthroughoutthelifecycle,providingourcustomersafsterasierndamoreccuratewayin everydayduties.
Management software
The IDUsareconnectedtoacomputerbythedataacquisition module,sothatfullcentralizedcontrolcanbeimplemented onthis management software.Thecontrolfunction is verypowerful,andoperationsare simpleand clear.One setof softwaresupportsupto32systemsand2048IDUsforlarge-scalecentralizedcontrol.Thecontrolsignalofdataacquisition module can reach up to 1 2 0 0 ~ { m } 业
Freemanagementby group
Completeschedulemanagement
Historical data records
Schedule control byweek/month/year
Centralized control function
Centralized control overair conditioning systems in multiple buildingsat the same place
Permission setting
Temperature seting,timer power-on/-off
Errorreporting
Interlocking control
Remotemanagement
| Model | Appearance | Dimension | ||||||||
| Gas side joints ID15.88 OD15.88D12.7 | Liquid side joints | |||||||||
| TBP4022TA | ID19.05ID15.880D15.88 353035 ID22.23 | ID9.52_OD9.52 | ID6.35 D6.35 | ID9.52 ID9.52/ 170 ID12.7ID9.52 | ||||||
| ID15.881D15.88D12.7 300 ID22.23OD22.23 | ||||||||||
| ID22.23 | ID22.23 OD22.23ID19.051D15.88 ID28.58 | ID12.70D12.7 ID12.7 ID9 ID6.35 200 ID15.88OD15.88ID12.7 | ||||||||
| ID28.58OD28.58 23 | ID25.4ID22.23 ID22.23 ID19.05ID15.880D15.88 353535 ID25.4ID22.23 | |||||||||
| hn | ID28.58/ 303 ID38.1OD38.1 403530 | |||||||||
| TBP4073TA | ID38.1ID34.9 ID31.75 298 | |||||||||
| OD28. ID31.75 | 3535 1D22.231D1905OD15.88 ID28.6ID25.41D22.2 | |||||||||
| 292 OD28.6 | ID12.7 353035 35 35 ID15.886D15.88D12.7 300 ID15.88OD15.88 ID12.7 ID19.05 ND15.88OD15.88 35 ID15.88OD15.88 | |||||||||
| ID22.23 | ||||||||||
| D38.1ID34.9ID31.75 | 1ID22.2 OD22.2ID19.05ID15.88 | |||||||||
| TBP4135TA | ID31.75 | ID28.6ID25.4ID222 292 | D15.88/0015.88/ID12.7 | |||||||
| ID38.1003 | ID22.2 DD22 | |||||||||