TA-CLASS AIR-COOLED CHILLERS
GLOBAL #1 IN OIL-FREE CHILLERS
AE RANGE
Smardt TA-class Air-cooled Chillers
This publication contains information proprietary and confidential to Smardt Chiller Group Inc. and its subsidiary companies
(“Smardt”). Any reproduction, disclosure or unauthorized use of this publication is expressly prohibited without written permission from
Smardt. Smardt reserves the right to make changes to the product or component design as and when warranted and without notice, in
line with user needs or evolution in engineering and manufacturing technologies.
Smardt has exercised its best efforts to ensure that the information contained in this publication is correct at time of printing. However,
no warranty, reliability or accuracy is given with respect to the information contained herein, and Smardt is not and shall not be
responsible for any error or omission, or liable for the correctness or suitability of the information given. All brand names and product
names used in this publication are trademarks, registered trademarks, or trade copyrights of Smardt.
T-CLASS CHILLERS
© 2019, Smardt Chiller Group Inc. All rights reserved.
Contents
AE TA-CLASS OVERVIEW ..........................................................................................................................5
FEATURES AND BENEFITS ........................................................................................................................6
Oil-Free Compressor Technology................................................................................................................ 6
High Efficiency .............................................................................................................................................. 6
Corrosion Protection ..................................................................................................................................... 6
Environmentally Responsible........................................................................................................................ 6
Adaptable by Design ................................................................................................................................... 6
Durable Frame Construction ........................................................................................................................ 7
Control System.............................................................................................................................................. 7
Web-based Control Panel ........................................................................................................................... 7
Serviceability................................................................................................................................................. 7
Reliability & Redundancy............................................................................................................................. 7
Packaged Construction ................................................................................................................................ 7
HTML INTERFACE ......................................................................................................................................8
Remote Connectivity..................................................................................................................................... 8
CAPACITY RANGE - R134A......................................................................................................................9
CAPACITY RANGE - R1234ZE................................................................................................................10
Options .....................................................................................................................................................11
Economizers................................................................................................................................................ 13
Alternative Insulation .................................................................................................................................. 13
Passive Noise Insulation............................................................................................................................. 13
High Static Fans .......................................................................................................................................... 13
Rapid Restart ............................................................................................................................................... 13
High-Level Communications...................................................................................................................... 13
Power Monitoring ...................................................................................................................................... 13
Active Noise Control .................................................................................................................................. 13
Coil Construction ........................................................................................................................................ 14
Flanged Connections.................................................................................................................................. 14
Condenser Access Hatches ....................................................................................................................... 15
Stainless Steel Enclosures........................................................................................................................... 15
SMARDT Lift ................................................................................................................................................ 16
Frame Construction..................................................................................................................................... 16
PHYSICAL DATA.......................................................................................................................................17
APPLICATION CONSIDERATIONS.........................................................................................................18
Appropriate Climate................................................................................................................................... 18
Chilled Water Requirements ...................................................................................................................... 18
Evaporator Water Circuits.......................................................................................................................... 18
Flow Safety Interlocks................................................................................................................................. 18
INSTALLATION REQUIREMENTS ...........................................................................................................19
Site Clearances........................................................................................................................................... 19
Mounting Requirements.............................................................................................................................. 19
ENGINEERING SPECIFICATIONS......................................................................................................... 20
CHILLER NOMENCLATURE.................................................................................................................... 22
Smardt TA-class Air-cooled Chillers
[This Page is Intentionally Left Blank]
© 2019, Smardt Chiller Group Inc. All rights reserved. 5
AE TA-CLASS OVERVIEW
Smardt’s range of AE TA-class air-cooled chillers has
been designed to reliably deliver high efficiencies
across a wide range of operating conditions.
It features a base range of models, each with
extendable condensers and performance options,
creating a multitude of combinations to suit any
project requirement.
•Smardt has brought its extensive experience in oil-free
chiller development, sales and service into designing the
AE TA-class – a range of air-cooled chillers that delivers
the highest level of reliability, outstanding efficiency and
the lowest total cost of ownership.
•All Smardt chillers are designed to optimize the superior
performance of oil-free compressors from Danfoss
Turbocor® and the AE TA-class is no exception. These
compressors, coupled with our extendable condenser
design and high efficiency evaporator, result in the
highest efficiency air-cooled chiller.
•Our class leading performance and quality design
ensures the best results for total equipment life cycle
operation and reliability.
•The AE TA-class range comes with the same benefits as
all Smardt chillers, such as ease of installation, simplicity
of operation and maintenance, and lower operating and
maintenance costs.
• ADAPTABLE BY DESIGN - A BASE RANGE
WITH OPTIONS TO SUIT ANY AIR-COOLED
APPLICATION
• DESIGNED FOR EASE OF MAINTENANCE
AND SERVICEABILITY
• ADVANCED CORROSION PROTECTION ON
CRITICAL OPERATING SURFACE AREAS
• ACCURATELY DESIGNED FOR TROUBLEFREE AND SUSTAINED OPERATION
ACROSS THE ENTIRE CHILLER LOAD RANGE
• MANUFACTURED GLOBALLY, ACCEPTANCE
TESTED AND PRE-COMMISSIONED PRIOR
TO DELIVERY ENSURING TROUBLE-FREE
COMMISSIONING AND START-UP ON
EVERY PROJECT
HIGHLIGHTS
6 Smardt TA-class Air-cooled Chillers
CORROSION PROTECTION
The TA-class chiller range has been designed with hostile
environmental conditions in mind, utilizing a range of
corrosion-resistant materials and industry-leading coatings.
It is intended that this manual be used with the applicable
installation drawings and wiring diagrams supplied with
your chiller. The information provided is general in nature
and is subject to change as part of Smardt’s commitment
to continuous product improvement. For specific
application information, contact your nearest Smardt sales
representative.
ENVIRONMENTALLY RESPONSIBLE
All TA-class chillers utilize non-toxic refrigerants with zero
ozone-depletion potential. Additionally a range of low
GWP HFO refrigerants are available, compliant with long
term EU F-gas regulations.
ADAPTABLE BY DESIGN
The configuration of each AE TA-class base model is
extremely flexible in performance and footprint, and can
be adapted to suit any air-cooled application.
The AE TA-class extendable condenser design allows
for a range of different efficiency options based on job
location, application and critical operating environment.
In addition, an extensive range of performance, functional
and connectivity options are offered - all specific to project
application and customer requirements.
The AE TA-class chiller range features a highefficiency extendable condenser, with multiple
performance options, packaged on a compact, yet
robust structural frame.
OIL-FREE COMPRESSOR TECHNOLOGY
At the core of all Smardt chillers is an oil-free Danfoss
Turbocor® compressor, featuring magnetic bearing
technology. With no oil to compromise heat exchanger
performance, and no friction losses associated with
conventional compressor bearings, Smardt chillers are
able to achieve exceptional full- and part-load efficiencies.
This ultra high speed technology eliminates up to 99% of
compressor induced vibrations, and dramatically reduces
the sound levels emitted by the chiller.
HIGH EFFICIENCY
In addition to its compressor technology, the AE TA-class
utilizes high performance aluminum/copper coils and
industry-leading EC fan technology as standard to deliver
a highly-efficient refrigeration circuit. All Smardt chillers use
premium flooded shell and tube heat exchangers which
have superior efficiency and reliability to plate and frame
or DX heat exchangers.
FEATURES AND BENEFITS
© 2019, Smardt Chiller Group Inc. All rights reserved. 7
DURABLE FRAME CONSTRUCTION
An all-new space frame has been specially engineered as
the platform for the AE TA-class range of chillers. Substantial
reductions in embodied energy have been achieved
through a refined design, resulting in a rigid, yet lightweight
structure. This design provides a strong and durable frame
for worry-free lifting, installation and longevity.
CONTROL SYSTEM
Proven across years of industry experience in oil-free chiller
operation, Smardt’s advanced chiller controller is designed
to optimize the performance and capabilities of the AE
TA-class chiller range. Capacity can be reduced to as
little as 10% of full-load capacity. Simple integration with
building management systems via MODBUS is provided as
standard.
WEB-BASED CONTROL PANEL
The Smardt Control provides a web-based alternative to
traditional hardware controls. Using the HTML-based web
panel software in combination with the local touchscreen
interface display gives the customer both the ease-of-use
of a traditional control panel and the flexibility of a web
panel. The web panel software is installed on any digital
device (e.g., cell phone, tablet or computer) running a web
browser with access to the local network or via a secure
VPN connection. The interface software is installed on
the chiller controller. Switching between different control
panels is as easy as following a web link. Smardt offers
a modem connection option so any device connected to
the internet can remotely access the chiller via a secure
password protected connection.
SERVICEABILITY
All Smardt chillers are available with refrigerant isolation
valves on both sides of serviceable components, to
minimize ongoing maintenance requirements. This
facilitates servicing without the need to pump down the
entire unit, and in most cases can be undertaken while the
chiller remains operational. The majority of serviceable
components are readily accessible from the perimeter
of the unit, with each compressor easily accessible in
its weather resistant cover. The controller interface is
conveniently housed in a separate lockable enclosure
located between condenser coils where it is shielded from
rain and sun glare.
RELIABILITY & REDUNDANCY
With the experience of more than 8000 oil-free centrifugal
chillers now installed worldwide, Smardt chillers offer
outstanding reliability - unsurprising when an estimated
80% of all chiller field problems relate to failures in the
compressor oil-return. On multiple-compressor models,
mechanical and electrical isolation provides significant
redundancy and failsafes. In the event of a compressor
outage, Smardt’s controller will automatically adjust its
logic to continue serving the chilled water load with the
remaining available compressors. Should a compressor
require servicing, it can be quickly and easily isolated, even
removed, without stopping the chiller.
PACKAGED CONSTRUCTION
All Smardt chillers are factory assembled and tested,
ensuring trouble-free start-up and commissioning.
8 Smardt TA-class Air-cooled Chillers
HTML INTERFACE
LOCAL INTERFACE
SOFTWARE ON
CHILLER
CONTROLLER
HTML-BASED WEB
PANEL SOFTWARE
ON DEVICES
HTML-BASED
WEB PANEL APP
ON DEVICES
REMOTE CONNECTIVITY
All Smardt AE TA-class chillers feature an integrated
HTML server that can be configured to deliver real-time
monitoring of chiller performance on any web-enabled
device connected to the same local area network as the
chiller. Remote viewing of this data would also be made
possible with a secure VPN connection.
The HTML server features an inbuilt firewall which provides
security against unauthorized access to the chiller. The
firewall has been independently tested to OSSTMM;
which is internationally recognized as best practice in
vulnerability assessment and penetration testing.
© 2019, Smardt Chiller Group Inc. All rights reserved. 9
CAPACITY RANGE - R134A
The AE TA-class range has been designed to meet a wide variety of applications, with full-load capacities ranging from 200
kW up to 1800 kW.
Note: Available cooling capacity will vary with operating conditions
and chiller configuration. Capacities shown are based on standard
AHRI conditions.
Base Models
Economized
Selectable Full-Load Range
Unloading Capacity
Cooling Capacity [kW]
10 Smardt TA-class Air-cooled Chillers
CAPACITY RANGE - R1234ZE
The AE TA-class range has been designed to meet a wide variety of applications, with full-load capacities ranging from 200
kW up to 960 kW.
Note: Available cooling capacity will vary with operating conditions
and chiller configuration. Capacities shown are based on standard
AHRI conditions.
Economized
Unloading Capacity
Selectable Full-Load Range
Cooling Capacity [kW]
Base Models
© 2019, Smardt Chiller Group Inc. All rights reserved. 11
OPTIONS
12 Smardt TA-class Air-cooled Chillers
Options
© 2019, Smardt Chiller Group Inc. All rights reserved. 13
AVAILABLE OPTIONS
Every project is unique, yet a wide range of available
options allows the AE TA- class chiller range to be adapted
to any air-cooled application.
ECONOMIZERS
Economizers are available on all models, which extend the
capacity of the chiller and/or further increase its operating
efficiency.
ALTERNATIVE INSULATION
All models are fitted with 19 mm closed-cell rubber,
wrapped in 3 mm thick UV stabilized insertion rubber,
as standard. 38 mm rubber, aluminum cladding, 50 mm
polystyrene and 50 mm polyurethane options are also
available.
PASSIVE NOISE INSULATION
Virtually vibration-free, and featuring industry leading fan
technology, AE TA-class chillers are already amongst the
quietest air-cooled chillers on the market.
For noise-sensitive installations, where additional noise
dampening is required, Passive Noise measures can be
factory-fitted.
These measures provide a constant reduction in noise
levels without affecting the performance or efficiency of the
chiller.
FRAME - Stainless / Electro
HIGH STATIC FANS
High efficiency EC fans are installed as standard on all AE
TA- class models. Where increased condenser performance
is desired, or external static must be overcome, high static
fans enable continued efficient and reliable performance.
RAPID RESTART
Designed for critical installations, Rapid Restart allows
the chiller to resume operation in as little as 20 seconds
following power supply restoration.
HIGH-LEVEL COMMUNICATIONS
MODBUS RTU high-level communication is installed as
standard across all models. BACnet MSTP/IP, MODBUS
TCP/IP, and LON communication options are also
available.
POWER MONITORING
An integrated monitoring system, providing absolute power
usage and quality in real-time over HLI.
ACTIVE NOISE CONTROL
For installations where stringent time of use noise restrictions
apply, i.e. residential nighttime applications, an Active
Noise Control system allows the user to limit the chiller’s
noise levels throughout specific periods of operation.
14 Smardt TA-class Air-cooled Chillers
AVAILABLE OPTIONS (CONT’D)
COIL CONSTRUCTION
AE TA-class chillers are now available with two styles of
condenser heat exchanger construction:
•All-aluminum micro-channel: ideal for efficient and
economical operation.
•Tube and fin: ideal for hostile environments, featuring a
robust marine-grade aluminum frame, and available in a
number of materials and finishes:
• Aluminum or copper fins
• Hydrophobic + epoxy fin coating, or
• Nano hydrophyllic coating, or
• SBS electrophoretically dipped coating.
FLANGED CONNECTIONS
Chilled water connections may be customized to suit a
range of local standards, including:
• ANSI Class 150 (available globally)
• AS 2129 Table E (Asia-Pacific only)
• GB/T 9112 PN16 (China Only)
• DIN PN16 (available globally)
Enquire with your local Smardt sales representative for
requirements not listed above.
© 2019, Smardt Chiller Group Inc. All rights reserved. 15
AVAILABLE OPTIONS (CONT’D).
CONDENSER ACCESS HATCHES
Complete access to the inside of each condenser module
allows faster and more complete maintenance of the
condenser coils and fans.
This option may be factory-fitted on all AE TA-class models.
STAINLESS STEEL ENCLOSURES
All AE TA-class electrical enclosures are powder-coated.
For additional protection, powder-coated stainless steel
enclosures are available.
16 Smardt TA-class Air-cooled Chillers
AVAILABLE OPTIONS (CONT’D).
SMARDT LIFT
Designed to monitor and actively support the compressor’s
liquid-cooling system, Smardt Lift allows AE TA-class chillers
to operate in previously prohibitive conditions.
Best utilized where chilled water temperatures approach
ambient conditions, Smardt Lift enables the chiller to
continue delivering full cooling load while enhancing the
system’s efficiency.
Smardt Lift can be included as a factory-fitted option on all
models, or retrofitted later in the field.
FRAME CONSTRUCTION
For premium protection in corrosive environments, the
AE TA-class chiller’s frame may be constructed entirely of
stainless steel, and assembled using only stainless steel
fasteners.
© 2019, Smardt Chiller Group Inc. All rights reserved. 17
PHYSICAL DATA
BASE MODEL PASS
COUNT
FANS
QTY
COMP
QTY
OVERALL LENGTH
'L' (MM)
OPERATING
WEIGHT* (KG)
SHIPPING
WEIGHT** (KG)
AE022.1F 3 4 1 2610 2064 2009
3 6 1 3600 2459 2399
AE028.1B 3 4 1 2610 2064 2009
3 6 1 3600 2459 2399
4 4 1 2610 1994 1924
4 6 1 3600 2489 2414
AE030.1A 3 6 1 3600 2300 2256
3 8 1 4800 2650 2611
AE040.1E 3 6 1 3600 2300 2256
3 8 1 4800 2650 2611
4 6 1 3600 2300 2257
4 8 1 4800 2650 2607
AE044.2F 2 8 2 4800 2805 2749
2 10 2 6000 3480 3446
AE054.2B 2 8 2 4800 2805 2749
2 10 2 6000 3480 3446
AE060.2A 2 10 2 6000 3545 3492
2 12 2 7200 3890 3832
AE065.2E 2 10 2 6000 3545 3492
2 12 2 7200 3890 3823
AE066.3F 2 12 3 7200 4475 4397
2 14 3 8400 4815 4737
AE080.2E 2 12 2 7200 4350 4280
2 14 2 8400 4350 4280
AE086.3B 2 12 3 7200 4475 4397
2 14 3 8400 4815 4737
AE090.3A 2 16 3 9600 5450 5348
AE120.3E 2 14 3 9600 5450 5348
* Operating weights provided in the table above include standard-fitted features only. Additional options and extras may change these values. Please consult Smardt for more information.
** Shipping weights provided include refrigerant, which may be excluded from shipping where requested.
18 Smardt TA-class Air-cooled Chillers
APPLICATION CONSIDERATIONS
APPROPRIATE CLIMATE
Humidity has little effect on the efficiency of an air-cooled
chiller, therefore giving the AE TA-class the greatest
advantage in high-humidity environments.
For applications involving lower humidity, consider
Smardt’s EE range of E-Class high efficiency, oil-free,
purpose built evaporative chillers.
CHILLED WATER REQUIREMENTS
All external pipework must be self-supporting, and aligned
to prevent strain and distortion on the chiller’s headers and
couplings.
EVAPORATOR WATER CIRCUITS
The chiller performance and efficiency can be adversely
affected by contaminants in the water circuit. As such,
strainers should be located on the inlet side of the
evaporator.
The water circuit should be arranged so that the pumps
discharge through the evaporator, with the return water
to the chiller connected to the lower connection of the
evaporator.
FLOW SAFETY INTERLOCKS
Differential pressure (DP) transmitters enable the chiller
to shutdown in the event of low or high flow through
the evaporator and are fitted as standard on all Smardt
chillers.
An additional field-supplied chilled water pump interlock,
or a VSD interlock signal s required on all installations.
If the chiller is intended for an application using variable
chilled water flow, please confirm the appropriate cut off
point with Smardt.
DP
SUPPLIED
I
EXTERNAL
© 2019, Smardt Chiller Group Inc. All rights reserved. 19
INSTALLATION REQUIREMENTS
SITE CLEARANCES
A nominal clearance of 2000 mm is required around
all four (4) sides of AE TA-class chillers, and 3660 mm
between adjacent chillers.
A clearance equal to the length of the evaporator is
recommended at either end of the vessel for service access
requirements.
Installations with a raised platform that permits freeflowing fresh air supply to the chiller may achieve smaller
clearances. Contact Smardt for advice on restrictive
installations needs, please contact a Smardt representative
at sales@smardt.com.
MOUNTING REQUIREMENTS
The chiller shall be installed on a flat surface, with a
minimum of 75 mm flange width around the perimeter of
the base frame. Refer to individual product information for
these dimensions.
Waffle pads can be used in place of spring mounts for most
installations requiring structural isolation.
All enclosures are NIP54 (NEMA 3R equivalent) rated and
contain high quality components, thus providing you with
a reliable and safe product. Please note that access to the
electrical enclosures are restricted to qualified personnel
only.
20 Smardt TA-class Air-cooled Chillers
ENGINEERING SPECIFICATIONS
DESCRIPTION
Microprocessor controlled, electric water chiller using non-toxic
and zero ozone-depletion potential refrigerant, oil-free, two
stage centrifugal variable speed compressor and high efficiency
corrosion-resistant condenser.
QUALITY ASSURANCE
Construction shall comply with relevant country codes; vessels
shall be manufactured in accordance with ASME code or
AS1210. Selected units can be run tested at the factory prior to
shipment (optional).
EQUIPMENT
Fully integrated, factory assembled, air-cooled packaged liquid
chiller fitted with oil-free magnetic bearing compressors, variable
speed EC fans, and all factory wiring, piping, controls and
refrigerant. Chiller shall be certified in accordance with AHRI
Standard 550/590 (I-P).
COMPRESSOR
The compressor(s) shall be an oil-free semi-hermetic two stage
direct driven variable speed centrifugal. Compressor(s) shall be
equipped with discharge and suction shutoff (isolating) valves for
mechanical isolation as standard.
Capacity control shall be provided by VSD (variable speed
drive) and inlet guide vanes, capable of reducing unit capacity to
below 15% of full-load.
Compressor shall start unloaded and current inrush shall be
limited by control to less than 5 Amps.
Motor cooling shall be provided by an integrated liquid
refrigerant injection system controlled by the compressor(s). The
compressor(s) shall require no oil lubrication.
Compressors shall be housed in UV-stabilized HMWPE plastic
enclosures with quick release covers which when removed
provide full access for servicing requirements.
EVAPORATOR
Provide shell and tube design evaporator with seamless copper
tubes mechanically expanded into boiler quality mild steel tube
sheets with mild steel water boxes. Form the evaporator shell from
carbon steel plate, designed, tested and stamped in accordance
with AS1210 or ASME safety codes for unfired pressure vessels.
Rate the water tubes to a pressure to suit the installation but in any
case be not less than 1000 kPa.
Insulate the evaporator with 19 mm closed cell PVC nitrile rubber
sponge and further wrap with 3 mm thick stabilized insertion
rubber.
• In corrosive environments: vertically-finned coils shall be
post-coated with an electrophoretic process to achieve
precise and consistent coating across entire coil including
fin edge seal. Finished surface includes oven bake curing
and UV protective top coating. The coil coating shall be salt
spray certified to ASTM B117-97/DIN 53167 for 6,000 hrs.
Structural panels shall be shrouded with full size covers made of
HMWPE (high molecular weight polyethylene) with added UV
and colour stabilizers.
All fixings shall be of stainless steel.
REFRIGERATION COMPONENTS
Pressure relief valves shall be provided on the evaporator in a
paired assembly to allow for either to be isolated without the
introduction of any safety hazard.
Each compressor shall be fitted with discharge and suction
isolation valves.
Electronic expansion valves shall be provided.
Electronic level sensors shall be provided to allow for accurate
expansion valve control.
Evaporator shall be fitted with a sight glass to allow for visual
inspection of the tubes.
There shall be isolation valves within the refrigeration pipework to
allow for rapid serviceability of individual components. Isolatable
components shall be accompanied by a service port to allow for
localized refrigerant reclaim.
STANDARD CONTROLS, INTERLOCKS & SAFETIES
Provide and mount in the chiller set control cubicle the interlocks,
time delays, relays, surge controls, capacity control, safety
controls, relays, connections for interlocks with external pumps
and flow switches etc. necessary for safe and satisfactory
operation and for restarting the chiller set immediately upon
restoration of interrupted power supply.
Unit controls shall include the following minimum components:
• Microprocessor control with non-volatile memory
• Power and control circuit terminal blocks
• ON/OFF control switch
• Temperature sensors installed to measure cooler entering
and leaving fluid temperatures
• Sensors for suction and discharge pressures
• Sensors for suction and discharge temperatures
Unit controls shall include the following functions as standard:
•Capacity control based on leaving or entering chilled water
temperature with set point offset load compensation.
•Rate of change control at start-up to prevent overshoot.
•Control of condenser fans to optimize condensing pressure
and maximize efficiency.
•Auto restart after power failure.
•The control panel shall include a clear backlit, colour LCD
touchscreen with menu driven user interface for setting of
user set points and options, and for providing operating
information descriptions.
Unit controls shall include the following display variables as part
of the user interface:
• General operational data including: entering and leaving
chilled water temperatures, chilled water set point, ambient
air temperature, time and date, active timers, system
demand, chiller status, active faults and alarms.
© 2019, Smardt Chiller Group Inc. All rights reserved. 21
• Compressor data including: communication integrity, active
alarms, actual compressor(s) demand, impeller speed, IGV
position, active pressure ratio, suction pressure, discharge
pressure, active power input, desired power input, 3 phase
Amps, surge RPM, choke RPM.
• Trending Data including: entering and leaving chilled water
temperatures, input kW, % of design chilled water flow, %
of design capacity, system refrigerant level, EXV position,
suction and discharge pressures, saturated suction
temperatures, saturated discharge temperatures, system
demand, number of compressors running.
• The control system shall allow software upgrade without the
need for new hardware.
• The control system shall allow software upgrade without the
need for new hardware.
• Controller shall include contacts for interfacing to the
building management system via high level standard
communication protocol interface: Modbus™, TCP/IP native,
Modbus™, RTU RS485, LonTalk®, FT-10 module, BacNet™,
MSTP, BacNet™,IP, for the following functions: Summary
fault, Start/Stop, Chilled water flow interlock, Chiller water
reset and Demand limit.
Unit(s) shall be equipped to provide the following protection:
•Loss of refrigerant charge
•Low chilled water temperature
•Power supply error
•Compressor motor thermal or electrical overload
•Phase loss
•High pressure
•Low pressure
•Loss of chilled water flow.
OPERATING CHARACTERISTICS
Unit shall be capable of starting up with 35 °C entering fluid
temperature to the cooler and sustained operation in ambient air
on conditions exceeding 40 °C.
ELECTRICAL
• Unit primary electrical power supply shall enter the unit at a
single location
• Unit shall operate on 3-phase power at local voltage and
frequency
• Control voltage shall be 24 VDC
• Unit shall be shipped with factory installed control and
power wiring.
• Power factor shall be greater than 0.9 (compressors only) at
full design load
• Provide EMI filtration for high frequencies EMC compliance
• High impedance reactors providing enhanced low
frequency harmonic mitigation
UNIT OPTIONS
• Remote monitoring via HTML
• Smardt Lift for enhanced operating range and efficiency
• Economizers for extended full-load operating range/
efficiency
• Passive or Active Noise Control strategies
• High static fans
• Hydrophobic + epoxy-coated condenser coil fins – 1000
hrs salt
spray rating
• Nano-coated condenser coils – dust repellent with a 5000
hrs salt spray rating
• Premium frame construction, manufactured entirely of
stainless steel
• Alternative evaporator insulation
• Stainless steel electrical enclosures
• Flanged chilled water connections
• Rapid Restart.
22 Smardt TA-class Air-cooled Chillers
CHILLER NOMENCLATURE
© 2019, Smardt Chiller Group Inc. All rights reserved. 23
[This Page is Intentionally Left Blank]
24 Smardt TA-class Air-cooled Chillers
CHILLER GROUP
ASIA PACIFIC
CHINA
Mei Xing Industrial Park
No. 30 Dong Zhong Road ETDD
Hangzhou
T +86 20 8205 7161
E info@smardtchina.com
SINGAPORE
438A Alexandra Road #08-11
Alexandra Technopark 119967
T +65 6273 1120
E sales.as@smardt.com
AUSTRALIA
144 Colchester Road
Bayswater North VIC 3153
T +61 3 9761 7905
E sales.au@smardt.com
AMERICAS
CANADA
1800 Trans Canada Highway
Dorval Quebec H9P1H7
T +1 514 426 8989
E sales@smardt.com
USA
22 Colorado Street Bldg2815
Plattsburgh NY 12903
T +1 518 324 5741
E sales@smardt.com
BRAZIL
Smardt-Transcalor
Av. Eldorado, 187 – Jardim Ruyce – Diadema
SP – Brasil – CEP: 09961-470
T +55 11 4351-4089 / 4351-3803
E contato@transcalor.com.br
EUROPE, MIDDLE EAST, AFRICA
GERMANY
Bahnhofstraße 74 D73240 Wendlingen
T +49 7024 79429 0
E info.eu@smardt.com
02/19 Metric