1301型电子式电动双座调节阀
65
Product
BAIC GROUP
1301 Type Electronic-Type Electric Double-Seat Regulator
1301 type electronic-type electric double-seat regulator is composed of 3610L/
3810/PSL electronic integrated electric actuator (or intelligent electronic actuator)
and double-seat regulating mechanism. The electric actuator is equipped with a
servo system, so it does not need to be equipped with a servo amplifier, and it can
be controlled with an input signal and power supply, simple wiring, regulation
structure is characterized by small unbalance force, large allowable differential
pressure and large flow capacity. Suitable for high differential pressure, large flow
rate, with oscillation and large pressure changes occasions.
Double-seat valve generally leak more, so please take care when selecting a
model!
Specifications and technical parameters
Nominal diameter DN (mm) 25 32 40 50 65 80 100 125 150 200
Rated flow
coefficient Kv
Linear 12.5 19.5 30.5 48.4 76 125 195 305 484 760
Equal
percent 11 17.6 27.5 44 69 110 176 275 440 690
Rated stroke L(mm) 16 25 40 60
Matching electronic actuator
361LSA-08
381LSA-08
PSL201
361LSA-20
381LSA-20
PSL202
361LSB-30
381LSB-30
PSL204
361LSC-65
381LSC-65
PSL312
Nominal diameter DN (mm) 250 300 350 400
Rated Kv
Linear 1100 1760 2750 4400
Equal
percent 1000 1600 2500 4000
Rated stroke L(mm) 100 100 100 100
Matching electronic actuator 361LSC-99
381LSC-99/PSL316 361LSD-160 PSL320
Nominal
pressure PN
MPa 1.6,2.5,4.0,6.4(6.3),10.0
Bar 16,25,40,64(63),100
Lb ANSI:Class150, Class300, Class600
Intrinsic flow characteristics Linear (not recommend), equal percentages (preferred)
Intrinsic adjustable ratio (R) 50
Signal Input: 4-20mA/1-5V, feedback input: 4-20mA
Power supply 220V 50HZ (380V must be specified)
Allowable leakage amount(1/
h) Class II (5×10-3×rated valve capacity) metal hard seal
Operating
temperature t
(℃)
Normal
temperature
type
- 20~200-40~250-60~250
Heat
dissipation
type
-40~450 -60~450
High
temperature
type
(Use of high temperature materials) 450~650
Low
temperature
type
-60~-100 -100~-200 -200~-250
Cut-off type -40~150 (valve core clamp PTFE) -60~200 (valve core clamp reinforced PTFE)
1. Performance indicators of this product implement GB/T4213-92 standard
2. There is no double-seat valve for DN25 or below, DN250-400 is not a national unified
product, KV value should be noted!
66
Product
BAIC GROUP
Outline dimensions
1301 Type electric double-seat regulator outline dimensions table
Nominal
Nominal
Unit: mm
diameter D D3 D4 n-d
-100
H1
℃ -200℃ -250℃ Weight
Kg
diameter
H2
L
H H
H1
2
H
H
D
H
PN MPa
25
255
260 290
PN6.4MPa
8-14
1.6
102
4.0
500
6.4
1112
700
1312
25
900
160
1512
206
41
120
32
680
285
830
315 8-14
26
105
30
1118
33
1318
32
1518
180
44
210
40
120
255
683
305
834
335
255
8-16
28
127
31
1190
34
1390
40
1590
200
62
220
50
140
340
758
370
908
8-16
38
132
47
1200
51
1400
50
1600
230
67
286
65
145
370
768
400
919
10-16
41
171
51
600
55
1463
65
800
290
1663
311
1000
190
1863
989
100
1152
80
255
405
61
435
80
10-16
88
188
80
1489
310
1689
337
1889
210
112
1022
100
1185
460
77
490
100
12-18
110
200
100
1505
350
1705
394
1905
220
143
1042
125
1207
310
96
525
120
555
131
14-18
125
250
400
700
460
1842
270
900
1336
2042
1548
1100
310
2242
160
229
195
150
243
590
150
630
480
16-18
508
260
280
1585
1358
2052
1570
2252.
205
296
248
200
268
700
200
740
600
18-18
610
300
320
1892
1436
2092
1548
2292
275
471
402 435
250 730 752 450 1707 1947 485 605 665
300 850 819 465 1767 2005 635 758 828High temperature Normal temperature PN 1.6 MPa Heat dissipation high temperature Normal temperature
1301 Type electric double-seat low temperature regulator outline dimensions table
H2
Weight Kg
Unit: mm
Performance indicators
67
Product
BAIC GROUP
Item Indicator value
Basic error % ±1.0
Return difference % 1.0
Dead zone % 1.0
Initial-end points
deviation %
Power on
Initial point ±2.5
End point ±2.5
Power off
Initial point ±2.5
End point ±2.5
Rated stroke deviation % +2.5
Bonnet type
Connection dimensions and standards
Refer to 1301 type pneumatic membrane double-seat regulator chapter
Refer to 1301 type pneumatic membrane double-seat regulator chapter
Ordering information
When ordering, users are requested to provide the following materials
· Regulator name, model and purpose.
· Nominal diameter (mm), nominal pressure (MPa), operating temperature and range.
· Upstream pressure, downstream pressure.
· Media name and status, media flow rate.
· Valve body flange standards.
· Valve body structure length (flange surface distance L).
· Other special requirements (e.g., corrosion resistance requirements, explosion-proof
level requirements, leakage level limitation requirements, etc.).
Technical parameters are subject to change without notice!