Evaporation Condenser
YANTAI CITY AOWEI REFRIGERATION EQUIPMENTS CO.,LTD.
Heat Exchange Equipments
Safety and environmental protection,pay attention to life,care for health.
Aowei refrigeration equipment Co., Ltd is located in the coastal city of Yantai, which is one of the earliest private
enterprises established in the middle of 1980 s .The first generation founders with courage and wisdom have built
the company which is mainly engaged in refrigeration engineering and installation accessories. After several
decades of development, the company has grown up to refrigeration equipment industry chain leader under the
belief of self-improvement and social service. After taking over by the second generation owners, they devoted
himself to building a high-tech enterprise center with international competition inspirit. Now the company not only
have four professional refrigeration equipment manufacturing plant engineering company and trading company, but
also building a technology Research Institute where include researching and developing compressors and
compressor systems integration, cold chain integration mainly in frozen equipment.
Review the past and look forward to the future, greet the new age of development. Aowei company devote himself
to manufacturing matching with national standards and industry standard products as the company lifeline, and
always putting the customer's benefit as themselves. R&D and produce the products in conformity with the
international standards.
The Company Introduction
Aowei obey the national development strategy to manufacture products with advantages of \"green, low-carbon,
environmental protection,sustainable development\".All products and systems are intelligent, digital and realized
unmanned system. Developed a new generation series of screw refrigeration compressor successfully, the
structure and the type of line parameters have a big breakthrough. Especially for CO2 compressor and system,
more nearly to realize \"environmental protection, safe, and efficient\". The company is committed to one-stop
overall cold chain solutions and value-added services. Represented by the integrated carton quick freezer and
spiral freezer machine already get more than 110 patents. The compressor test platform with experimental device
and air cooler test platform laid a good foundation for the company to the higher level.
According to country laws and regulations, all the products of our company have already got the corresponding
certificates and licence.
Aowei will continue insisting the principle of \"brand strategy, well-designed\" to produce high -tech and customer
satisfactory products. Aowei is willing to join hands with all friends at home and abroad and create a bright future.
Model Explanation
SZNXⅡ - 600 A
Normal conditions heat removal (KW)
The vapor evaporate and take away the heat of the refrigerant. During operation, the cooling water
is pumped up to the nozzle on the top of condenser and evenly spraying to the outside surface of
condensing tubes and forming a water layer. The high temperature refrigerant gas come into the
condensing coils from top and condenses by cooling water into liquid and flow out from bottom. Some
water absorb the heat and become steam, the rest water drop to the water tank for re-circulation,
meanwhile, the fans on the top make wind with speed of 3~5 m/s to speed up the evaporation of the
water layer outside the surface of condensing tubes and also cool the dropping water which will get
back to spay onto the heat-exchange tubes. The steam is blown out by the blower and the blobs mixed
to the steam remain on the dehydrator. The floating valve in the tank control water supplement into the
tank automatically.
Working principle
01 Refrigerant code: A-R717(optional) F-R404A/R507A
Design code: II - Second Generation; Others no marks.
Series code: SZNX - Double effect evaporation condenser
ZNX - Evaporation condenser
GZN - Efficient evaporation condenser
Evaporation Condenser
Structure diagram
SZNX series evaporation condenser
Hot & wet air Fresh air
Fresh air
Water spray system
Condensing coil
Air guider
Water tank Water circulation pump
Dehydrator
Heat-exchange layer
Maintain passage
Axial flow fan
ZNX series evaporation condenser
Condensing coil
Dehydrator
Axial flow fan
Hot & wet air
Water spray system
Air guider
Fresh air Fresh air
Water tank
Water circulation pump
02
Construction features
We design the machine with advantages of novelty, unique and reasonable.
The condensation tubes and the interior metal components inside are hot-dipped galvanized (good
anti-corrosion and long lifetime).
Special tube arrangement makes the coil much smarter and more coil area in a fixed space to
enhance heat-exchange.
Patented dehydrator is used to reduce the water consumption.
The water spray nozzle is anti-blocked type to ensure even spraying.
The axial fans are low noise and large air-flow. The blades are made of aluminum alloy and the motor
is damp-proof.
Heat removal coefficient of R507A / R134 = Heat removal coefficient of R717 × 1.12(Except GZN series).
30
32
34
35
36
38
40
42
44
20
1.53
1.34
1.1
1.02
0.96
0.81
0.71
0.66
0.61
21
1.88
1.46
1.18
1.06
1.01
0.86
0.75
0.68
0.63
22
2.13
1.53
1.28
1.13
1.08
0.9
0.78
0.71
0.62
23
2.26
1.67
1.32
1.2
1.12
0.96
0.86
0.75
0.64
24
2.48
1.85
1.5
1.24
1.19
1.01
0.92
0.77
0.66
25
2.97
2.08
1.68
1.35
1.26
1.08
0.96
0.82
0.69
26
-
-
1.87
1.53
1.35
1.12
1.01
0.84
0.71
27
-
-
2.1
1.69
1.53
1.2
1.08
0.86
0.75
28
-
-
-
1.87
1.69
1.34
1.12
0.9
0.78
29
-
-
-
2.15
1.85
1.48
1.2
0.96
0.86
30
-
-
-
2.49
2.14
1.57
1.34
1.01
0.92
Condensing
temp. ℃
Wet ball temp. ℃
Coefficient table of heat removal - Ammonia (R717)
Advantages of evaporation condenser
● Power-saving: The condensing temperature of evaporation condenser is decided by wet ball
temperature. Normally, the wet ball temperature is 6~8℃ lower than ambient temperature. So we
designed the structure of the evaporation condenser according to this to lower the condensing
temperature and system pressure; so that to increase the refrigerating capacity of the compressor and
reduce the power consumption. The power of water pump is only 1/3~1/4 compared with other watercooled condenser. According to the calculation and operation, the power consumption of evaporation
condenser is 15% lower than water-cooled condenser.
●Water-saving: the evaporation condenser use water evaporation to take away the heat -1 liter of
water evaporated will take away 670W of heat. But water-cooled system use water heating-up to take
away the heat -1 liter of water only can take away 4~5W of heat. Therefore, to remove same volume of
heat the water-cooled condenser needs more water (we need to prepare large water tank, cooling
tower and cooling tubes which will bring more chance for water losing). Contrarily the evaporation
condenser needs less water and meanwhile the dehydrator of the machine has higher efficiency of
water reclaim. The water loss of evaporation condenser is only 10% of water-cooled condenser.
● Space-saving, easy to install and short duration.The evaporation condenser is an integrated
machine include condensing coil, cooling tower, water pond and water pump, which can be put on the
top of the roof. The piping system is simple and there is no other accessory of water system. It will
reduce the installation material, construction period and installation cost.
●Low maintenance cost. If we use evaporation condenser, the condensing temperature will be low,
what's more, the exhaust pressure, exhaust temperature and the temperature of lubrication oil are
also low. So the machine is working under a perfect condition, and the lifetime of the machine will be
longer and the running of the machine is more smoothly so that to reduce the maintenance cost.
03
04
SZNXⅡ-300
SZNXⅡ-350
SZNXⅡ-400
SZNXⅡ-450
SZNXⅡ-500
SZNXⅡ-550
SZNXⅡ-600
SZNXⅡ-650
SZNXⅡ-700
SZNXⅡ-800
SZNXⅡ-900
SZNXⅡ-1000
SZNXⅡ-1100
SZNXⅡ-1200
SZNXⅡ-1300
SZNXⅡ-1400
SZNXⅡ-1500
305
356
405
455
506
555
605
653
706
805
906
1005
1109
1206
1304
1407
1503
2460
2460
2460
2460
3000
3000
3000
3920
3920
3920
5000
5000
5600
5600
5600
5600
5600
2000
2070
2200
2140
2200
2110
2200
2170
2070
2200
2070
2170
2200
2200
2200
2200
2200
3715
3715
3715
3940
3715
3940
3940
4005
4240
4240
4295
4295
4320
4320
4320
4570
4570
2550
2550
2550
2550
2550
2550
2550
2810
2810
2810
2815
2815
2835
2835
2835
2835
2835
1035
1035
1035
1260
1035
1260
1260
1065
1295
1295
1344
1344
1344
1344
1344
1583
1583
2360
2520
2670
2850
3050
3160
3300
4000
4120
4400
5060
5320
5720
5955
6160
6480
6600
3500
3750
4000
4150
4500
4600
4750
5800
5950
6300
7200
7550
8350
8935
9200
9720
9900
60000
60000
60000
60000
60000
60000
60000
90000
90000
90000
120000
120000
120000
120000
150000
150000
150000
2.2×2
2.2×2
2.2×2
2.2×2
2.2×2
2.2×2
2.2×2
2.2×3
2.2×3
2.2×3
2.2×4
2.2×4
2.2×4
2.2×4
2.2×6
2.2×6
2.2×6
18.1
18.1
18.1
18.1
18.1
18.1
18.1
22.2
22.2
22.2
36.1
36.1
36.1
36.1
47.2
47.2
47.2
1.5
1.5
1.5
1.5
1.5
1.5
1.5
2.2
2.2
2.2
3.0
3.0
3.0
3.0
4.0
4.0
4.0
35
40
45
50
55
61
67
72
83
88
100
110
122
134
144
154
166
DN100
DN100
DN100
DN100
DN100
DN100
DN100
DN100
DN100
DN100
DN125
DN125
DN125
DN125
DN100×2
DN100×2
DN100×2
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65×2
DN65×2
DN65×2
SZNX II series evaporation condenser
Suitable for environment friendly refrigerants (such as R717、 R404A、 R507A, etc.)
The tube is oval type which is good for refrigerant flowing inside and good for water layer formatting
on the tube surface so that to enhance heat-exchange.
There is polyethylene heat exchange layer under the coil. Fresh cool air gets into the machine and
cools both the coil and the layer. On the way the water dropping to the water tank, the layer will cool
the water again to enhance the heat exchange result.
The air and water get in to the machine in same direction which will effectively speed up water flow
and reduce the filth appear on the condensing tubes.
Smart structure and all the models are easy to be transported in container (half-half or break up)
L W H h1 h2
Model
Normal
conditions
heat
exchange
kW
Weight(kg) Fan Water pump
Transport Air flow
3
(m /h)
Power
(kW)
Water
volume
3
(m /h)
Power
(kW)
Tube connection
dimension
(mm)
Operating Vapour in Liquid out
Outline dimension(mm)
L W
h2 h1
H
1
2
4
6
5
3
1. Refrigerant in 2. Refrigerant out 3. water supply in DN25 4. Maintain access 5. Overflow DN40 6. sewage outfall DN40
Evaporation Condenser
Ammonia
filled in
(kg)
W L
H
1
2
5
3
4
ZNX II series evaporation condenser
ZN XⅡ-320
ZN XⅡ-400
ZN XⅡ-480
ZN XⅡ-560
ZN XⅡ-640
ZN XⅡ-720
ZN XⅡ-800
ZN XⅡ-880
ZN XⅡ-960
ZN XⅡ-1100
ZN XⅡ-1200
ZN XⅡ-1300
ZN XⅡ-1400
ZN XⅡ-1500
ZN XⅡ-1600
ZN XⅡ-1700
ZN XⅡ-1800
322
402
481
565
645
722
805
884
962
1105
1203
1304
1406
1505
1603
1701
1804
2120
2120
2630
2630
2630
2630
3230
3230
3230
4240
4240
5000
5000
5000
5000
5600
5600
1275
1560
1500
1770
2000
2230
2040
2230
2040
2120
2230
2120
2230
2070
2150
2070
2200
2980
2980
2980
2980
3030
3030
3160
3160
3390
3210
3210
3330
3330
3560
3700
3700
3700
1160
1160
1160
1160
1210
1210
1260
1260
1260
1310
1310
1310
1415
1415
1415
1501
1501
1680
2000
2380
2680
3200
3560
3930
4140
4400
5130
5550
5980
6440
6900
7520
7910
8640
2480
3060
3400
3800
4400
5000
5900
6200
6710
7350
7760
8370
8500
9250
10500
11050
11700
30000
50000
50000
60000
60000
75000
90000
90000
90000
120000
120000
120000
120000
150000
150000
150000
150000
2.2
2.2×2
2.2×2
2.2×2
2.2×2
5.5
2.2×3
2.2×3
2.2×3
4×2
4×2
4×2
4×2
5.5×2
5.5×2
5.5×2
5.5×2
9.4
9.4
12.7
12.7
18.1
22.2
22.2
36.1
36.1
36.1
36.1
36.1
36.1
36.1
47.2
47.2
47.2
0.75
0.75
1.1
1.1
1.5
2.2
2.2
3.0
3.0
3.0
3.0
3.0
3.0
3.0
4.0
4.0
4.0
50
62
75
87
100
106
114
124
136
156
168
184
193
212
226
240
252
DN100
DN100
DN100
DN80×2
DN80×2
DN80×2
DN80×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN125×2
DN65
DN65
DN65
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
1. Refrigerant in 2. Refrigerant out 3. Overflow DN40 sewage outfall DN40 water supply in DN25 4. 5.
h1
h2
L W H h1 h2
Refrigerant
charge
(kg)
1035
1035
1035
1035
1035
1035
1065
1065
1296
1065
1065
1105
1105
1344
1344
1344
1344
Reasonable design all meet the conditions of container transport, simple and convenient.
The set of heat exchange tube, oval high-frequency welded pipe and the flow of the liquid in the pipe
and the pipe outer surface form a uniform water film, enhanced heat transfer effect.
05 Model
Normal
conditions
heat
exchange
(kW)
Weight(kg) Fan Water pump
Transport Air flow
3
(m /h)
Power
(kW)
Water
volume
3
(m /h)
Power
(kW)
Tube connection
dimension
(mm)
Operating Vapour in Liquid out
Outline dimension(mm)
Vapour in
06
GZN series evaporation condenser
GZN-50
GZN-70
GZN-90
GZN-110
GZN-130
GZN-150
GZN-170
GZN-190
GZN-210
GZN-230
GZN-250
GZN-280
GZN-300
GZN-350
51
70
91
112
132
154
172
191
215
235
252
285
302
352
840
1200
1380
1670
1980
2290
2570
2330
2570
2770
1865
2050
2220
2540
795
795
795
795
795
795
795
795
795
795
1395
1395
1395
1395
1950
1950
1950
1950
1950
1950
1950
2060
2060
2060
2100
2100
2100
2100
990
990
990
990
990
990
990
990
990
990
1130
1130
1130
1130
410
410
410
410
410
410
410
520
520
520
455
455
455
455
330
440
500
600
705
760
860
870
920
980
990
1050
1200
1340
550
720
830
1000
1180
1310
1490
1440
1550
1660
1810
1960
2190
2480
9000
15000
15000
18000
22200
22500
27000
27000
27000
27000
37000
37000
46900
46900
1.1
0.75×2
0.75×2
1.1×2
1.1×2
0.75×3
1.1×3
1.1×3
1.1×3
1.1×3
1.5×2
1.5×2
2.2×2
2.2×2
34
34
34
34
34
34
34
34
34
65
65
65
65
65
0.36
0.36×2
0.36×2
1.1
1.1
1.1
1.5
1.5
1.5
2.2
2.2
2.2
3
3
9
12
16
20
23
27
31
34
38
41
45
51
54
63
1
1 / \"8
1
1 / \"×2 8
1
1 / \"×2 8
1
1 / \"×2 8
1
1 / \"×3 8
1
1 / \"×4 8
1
1 / \"×4 8
1
1 / \"×4 8
1
1 / \"×4 8
1
1 / \"×4 8
3
1 / \"×3 8
3
1 / \"×3 8
3
1 / \"×4 8
3
1 / \"×4 8
7
/ \"8
7
/ \"×2 8
7
/ \"×2 8
7
/ \"×2 8
7
/ \"×3 8
7
/ \"×4 8
7
/ \"×4 8
7
/ \"×4 8
7
/ \"×4 8
7
/ \"×4 8
1
1 / \"×3 8
1
1 / \"×3 8
1
1 / \"×4 8
1
1 / \"×4 8
L W H h1 h2
Water pump
Water
volume
3
(m /h)
W
h1 h2
H
H
W
3
4
L
1
2
Suitable for environment friendly refrigerants (such as R404A、R507A, etc.)
The tube is made of copper which is clean and good at keeping clean; Special internal and external
dipteral type structure has nice heat-exchange result.
Smart size, light weight, nice heat-exchange result and easy to transport.
Smart structure and all the models are easy to be transported in container (half-half or break up)
1. Sewage outfall DN20 2. Water supply in DN15 3. Refrigerant in 4. Refrigerant out
SZNX series evaporation condenser
The tube is oval type which is good for refrigerant flowing inside and good for water layer formatting on the
tube surface so that to enhance heat-exchange.
Suitable for environment friendly refrigerants (such as R717、 R404A、 R507A, etc.)
There is polyethylene heat exchange layer under the coil. Fresh cool air gets into the machine and cools
both the coil and the layer. On the way the water dropping to the water tank, the polyethylene layer will cool
the water again to enhance the heat exchange result.
The air and water get in to the machine in same direction which will effectively speed up water flow and
reduce the filth appear on the condensing tubes.
Note: the \"nominal capacity\" as the refrigerant R507A, condensation temperature 35 ℃environment, on average, the biggest
change heat when the wet bulb temperature of 25.5 ℃.Selection should pay attention to the environment, on average, wet bulb
temperature increase 1 ℃, the selected model should be increased 15%.
Refrigerant
charge
(kg)
Model
Normal
conditions
heat
exchange
kW
Weight(kg) Fan
Transport Air flow
3
(m /h)
Power
(kW)
Power
(kW)
Tube connection
dimension
(mm)
Operating Vapour in Liquid out
Outline dimension(mm)
Evaporation Condenser
W L W
h2 h1
H
1
2
4
6
5
3
1. Refrigerant in 2. Refrigerant out 3. water supply in DN25 4. Maintain access 5. Overflow DN40 6. sewage outfall DN40
SZNX-350
SZNX-380
SZNX-410
SZNX-450
SZNX-500
SZNX-550
SZNX-600
SZNX-650
SZNX-700
SZNX-760
SZNX-820
SZNX-880
SZNX-940
SZNX-1000
SZNX-1040
SZNX-1100
SZNX-1160
SZNX-1200
SZNX-1280
SZNX-1380
SZNX-1460
SZNX-1520
SZNX-1600
SZNX-1680
SZNX-1760
SZNX-1800
SZNX-1860
SZNX-1920
SZNX-2000
SZNX-2100
SZNX-2200
352
385
412
452
506
555
601
652
705
762
826
888
942
1006
1045
1102
1163
1206
1288
1382
1466
1522
1606
1688
1765
1806
1862
1926
2008
2106
2208
2460
2460
2460
2460
3000
3000
3000
3000
3920
3920
3920
3920
3920
4240
4240
4240
4240
4240
5000
5000
5000
5000
5000
5600
5600
5600
5600
5600
5600
5600
5600
2200
2200
2200
2200
2600
2600
2600
2600
2600
2600
2600
2600
2600
2800
2800
2800
2800
2800
3000
3000
3000
3000
3000
3100
3100
3100
3100
3100
3500
3500
3500
3495
3720
3720
3720
3495
3720
3945
3945
3975
4210
4210
4440
4440
4210
4440
4440
4440
4440
4260
4500
4500
4500
4500
4280
4520
4520
4520
4520
4520
4520
4520
2550
2550
2550
2550
2550
2550
2550
2550
3010
3010
3010
3010
3010
3010
3010
3010
3010
3010
3015
3015
3015
3015
3015
3035
3035
3035
3035
3035
3035
3035
3035
810
1035
1035
1035
810
1035
1260
1260
834
1065
1065
1296
1296
1065
1296
1296
1296
1296
1105
1344
1344
1344
1344
1105
1344
1344
1344
1344
1344
1344
1344
2540
2650
2740
2840
3540
3700
3810
3940
4520
4660
4780
4900
5050
5240
5360
5480
5590
5650
6020
6240
6380
6460
6600
7740
7960
8080
8270
8450
9080
9310
9540
1610
1700
1800
1900
2320
2460
2560
2680
3050
3180
3290
3410
3550
3680
3800
3920
4020
4080
4410
4600
4730
4800
4930
5460
5640
5760
5940
6090
6400
6610
6820
4
6×10
4
6×10
4
6×10
4
6×10
4
7.5×10
4
7.5×10
4
7.5×10
4
7.5×10
5
1.2×10
5
1.2×10
5
1.2×10
5
1.2×10
5
1.2×10
5
1.5×10
5
1.5×10
5
1.5×10
5
1.5×10
5
1.5×10
5
1.5×10
5
1.8×10
5
1.8×10
5
1.8×10
5
1.8×10
5
2.25×10
5
2.25×10
5
2.25×10
5
2.25×10
5
2.25×10
5
2.55×10
5
2.55×10
5
2.55×10
2.2×2
2.2×2
2.2×2
2.2×2
5.5
5.5
5.5
5.5
4×2
4×2
4×2
4×2
4×2
5.5×2
5.5×2
5.5×2
5.5×2
5.5×2
5.5×2
4×3
4×3
4×3
4×3
5.5×3
5.5×3
5.5×3
5.5×3
5.5×3
7.5×3
7.5×3
7.5×3
65
65
65
65
80
80
80
80
130
130
130
130
130
130
130
130
130
130
170
170
170
170
170
230
230
230
230
230
230
230
230
1.5
1.5
1.5
1.5
2.2
2.2
2.2
2.2
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
3.0
4.0
4.0
4.0
4.0
4.0
5.5
5.5
5.5
5.5
5.5
5.5
5.5
5.5
40
44
48
52
56
61
66
71
77
83
90
96
102
110
115
121
125
160
142
156
160
166
174
182
195
201
204
218
235
252
264
L W H h1 h2 Heaviest
section
3930
4030
4120
4240
5680
5860
5960
6090
7400
7560
7680
7800
7950
8460
8580
8710
8820
8900
9480
9590
9730
9820
9960
12600
12830
12960
13130
13300
14580
14860
15100
DN100
DN100
DN100
DN100
DN100
DN100
DN100
DN100
DN80×2
DN80×2
DN80×2
DN80×2
DN80×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN100×2
DN125×2
DN125×2
DN125×2
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
07 Water pump
Water
volume
3
(m /h)
Refrigerant
charge
(kg)
Model
Normal
conditions
heat
exchange
kW
Weight(kg) Fan
Transport Air flow
3
(m /h)
Power
(kW)
Power
(kW)
Tube connection dimension
(mm)
Operating Vapour in Liquid out
Outline dimension(mm)
08
ZNX series evaporation condenser
ZNX-320
ZNX-400
ZNX-480
ZNX-560
ZNX-600
ZNX-640
ZNX-720
ZNX-800
ZNX-900
ZNX-1000
ZNX-1200
ZNX-1400
ZNX-1500
ZNX-1600
ZNX-1800
ZNX-2000
ZNX-2200
ZNX-2300
ZNX-2400
ZNX-2500
ZNX-2600
ZNX-2800
ZNX-3000
322
402
481
565
606
646
722
806
881
1010
1202
1415
1510
1606
1808
2008
2208
2306
2406
2508
2600
2808
3006
2120
2120
2630
2630
2630
2630
2630
2630
3920
3920
3920
4140
4320
4590
5160
5730
6330
6580
5500
5730
5990
6410
6840
1275
1560
1500
1770
1885
2000
2230
2455
1885
2110
2455
2350
2350
2350
2350
2350
2350
2350
2900
2900
2900
2900
2900
2980
2980
2980
2980
3030
3030
3030
3030
3280
3280
3450
3790
3790
3840
3840
3910
3910
3910
3910
4010
4010
4060
4060
1160
1160
1160
1160
1210
1210
1210
1210
1310
1310
1460
1526
1526
1576
1576
1646
1646
1646
1746
1746
1746
1796
1796
1035
1035
1035
1035
1035
1035
1035
1035
1065
1065
1065
1296
1296
1296
1296
1296
1296
1296
1296
1296
1296
1296
1296
1680
2000
2380
2680
3000
3200
3560
3600
4100
4680
4680
5390
6000
6500
7000
7500
8200
8900
9500
10300
10800
11500
12000
2480
3060
3400
3800
4200
4400
5000
5240
5560
6480
7260
8580
9000
9900
10350
12300
13350
14250
15000
15450
16200
17000
18200
4
3×10
4
5×10
4
5×10
4
6×10
4
6×10
4
6×10
4
7.5×10
4
7.5×10
4
9×10
4
9×10
5
1.2×10
5
1.2×10
5
1.2×10
5
1.5×10
5
1.5×10
5
1.8×10
5
1.8×10
5
2.0×10
5
2.25×10
5
2.25×10
5
2.25×10
5
2.4×10
5
2.4×10
2.2
2.2×2
2.2×2
2.2×2
2.2×2
2.2×2
5.5
5.5
2.2×3
2.2×3
4.0×2
4.0×2
4.0×2
5.5×2
5.5×2
4.0×3
4.0×3
4.0×4
5.5×3
5.5×3
5.5×3
4.0×4
4.0×4
34
34
46
46
65
65
80
80
80
130
130
130
130
170
170
230
230
230
230
130×2
130×2
170×2
170×2
0.75
0.75
1.1
1.1
1.5
1.5
2.2
2.2
2.2
3
3
3
3
4
4
5.5
5.5
5.5
5.5
3×2
3×2
4×2
4×2
50
62
75
87
93
100
106
114
124
146
168
195
211
222
235
255
275
298
320
347
371
384
405
L W H h1 h2
Water
volume
3
(m /h)
Suitable for environment friendly refrigerants (such as R717、 R404A、 R507A, etc.)
The tube is oval type which is good for refrigerant flowing inside and good for water layer formatting on the tube
surface so that to enhance heat-exchange.
D 100
DN100
DN100
DN80×2
DN80×2
DN80×2
DN80×2
DN80×2
DN100×2
DN100×2
DN100×2
DN100×4
DN100×4
DN100×4
DN100×4
DN100×4
DN100×6
DN100×6
DN100×4
DN100×4
DN100×6
DN100×6
DN100×6
D 65
DN65
DN65
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×2
DN65×4
DN65×4
DN65×4
DN65×4
DN65×4
DN65×6
DN65×6
DN65×4
DN65×4
DN65×6
DN65×6
DN65×6
ZNX-320~ZNX-1200 ZNX-1400~ZNX-3000
1. Refrigerant in 2. Refrigerant out 3. Overflow DN40 Sewage outfall DN40 5 Water supply in DN25 4. .
N N
Water pump
Refrigerant
charge
(kg)
Model
Normal
conditions
heat
exchange
kW
Weight(kg) Fan
Transport
Air flow
3
(m /h)
Power
(kW)
Tube connection
dimension
(mm)
Operating Vapour in Liquid out
Outline dimension(mm)
Power
(kW)
Evaporation Condenser
System management diagram
① Evaporation condenser
② Compressor
③ Cooling water pump
④ Underground water tank
Ball-cock
Ball valve
Butterfly valve
Check valve
Water flow direction in summer
Water flow direction in winter
Tap water
2、The volume of underground water tank should be more than total volumes that in the machine flume and
tubes.
3、The water return pipe of the compressor in the drawing I should be higher than the compressor. Water supply
pipe II could be put under ground. The height of valve F and its pipe should be lower than the pipe between
cooling pump and the compressor to ensure the water in the pipe being drained thoroughly in winter.
1、In winter make sure that the water in the cooling pump ③ and underground water tank ④ does not freeze.
2、In summer, the valves C, D, F and H should be closed, the rest valves should be opened.
3、In winter, close valves A, B, E and G, drain the water in the pipe between A-B and E-G from valve C and valve
D, open valve H. Before operation, start the cooling pump of the compressor first, and then start the spray pump
after the water in the tank is full. When the water pump is stopped, open value F to drain the water inside the tank
and pipeline to avoid water freezing inside. Before start the cooling water pump again, the value F must be
closed. In winter, the cooling water for the evaporation condenser and the compressor comes from the
underground tank. The value C could supply the consumed water.
1、This drawing is only an example. We could specially design for the user it according to conditions and actual
requirements.
In summer, water supply to the cooling pump ③ of the compressor comes from the water tank, and water level
inside the tank is controlled automatically by the ball-cock.
Attention
Explanation
1
2
3
2
A
E
B
C
F
D
H
G
4
09
10
High pressure vapor pipe
High pressure liquid pipe
Mixture gas pipe
Pressure equalizer
1、We suggest to use padding type oil separator for this system. If you want to use washing type oil separator,
please pay attention to the height. (Refer to the layout. Unit: mm)
2、The horizontal pipe between liquid out pipe and the receiver should have a grade of 1/50 along with
refrigerant direction.
3、Each vertical pipe for liquid out should have a U turn. For the height please refer to the drawing.
4、The distance between evaporation each condensers should be 1.5-2m.
Explanation
①
②
③
③
③
≥300
Connection diagram between evaporation condenser and high pressure system
A: Connect to exhaust main of air-cooler
B: Liquid-out pipe
C: Connect to gas inlet of air separator
① Washing type oil separator
② High pressure receiver
③ Evaporation condenser
Vapour in
Liquid out
Liquid out
Evaporation Condenser
Sales network
Since 1993, Aowei refrigeration equipments have been
sold to more than 20 provinces and municipalities in
China and also sold to Southeast Asia, Europe,
America, South Africa and others, total 30 countries and
regions.
We set up offices and after sales service center
all over China, and offer fastest technical
support and spare parts supply.
After sales service
Evaporation Condenser
2024.01Add:No. 199, Jinbu Street, Qinshui Industrial Zone, Muping district, Yantai, China.
Tel:86-535-3395800 3396796 FAX:86-535-3397996 After-sale service:86-535-3398887
http://www.aowid.com.cn E-mail:master@aowid.com.cn
Win-Win Cooperation Creating The Future Together