EUROPE R32 AII DC Inverter Air Conditioner
D1Series Duct / Cassette / Floor & Ceiling / Console / Light Commercial AC Slim Size 245mm Ceiling& Flooring 仓 Fresh Air { C _ { { * } } } Snow Blowing { / { 2 0 0 } { 0 } } High ESP Up to 200 Pa Twin System ⑦ WiFi App/OTA Airzone Solutions
FullDCInverter
AdoptDCinvertercompressorand motortoensurebeter energysavingand reliabilityofairconditioning system.
High Efficiency
Use high energy efficiency compressor,the product meets ERP standard,SEER of the unit can reach \mathsf { A } { + } { + } efficient level,andScOPcanreach \mathsf { A } + efficient level.
√ote:classA++:6.1<SEER<8.5 classA+:5.6≤SEER<6.1 classA:5.1<SEER<5.6 classB:4.6≤SEER<5.1
classA++:4.6≤SCOP<5.1 classA+:4.0≤SCOP<4.6 classA:3.4≤SCOP<4.0 classB:3.1≤SCOP<3.4
AmbientTemperature Range Long Piping Length Twin Split
Coolingand heatingsteadily from -25to 5 8 ^ { \circ } C Meet various of working conditionsandscenarios.
Pipe length reach 75m from ODU to IDU.The biggest gap reach 30m.
Connect 2 IDU,all indoor units ON/ OFFat the same time.
Refrigerant Recovery
When piping leaks or system in malfunction,refrigerant could be recovered and stored in ODU condenser.
Stability Design
Energy Saving Al Algorithms Operation
The full DC inverter intelligent airconditioning system can adjust the compressor speed accordingto Al algorithms.
Dust-Removing/Snow Blowing. Fanmotorrotatesreverse to remove dust/snow on fins. Maintaining the good performance of the condenser fins,enhance stability.
High ESP
ESP up to 2OoPa\* supports longer air duct and fits with more installation scenarios.
Fresh Air
Takeinoutdoor freshair,ensure that the indoorair is freshand circulated.
Seven Gear Wind Speed Ceiling& Floor Installation
Delicate fan speed adjustment.To satisfywindsensitiveusers'requirement,morecomfortable.
Support both ceiling concealed and floor concealed installation.
Soft Wind Panel (optional)
三三 电e 二
360of outlet wind,2565 micro-hole soft wind lades to break up the airflow,making the wind soft and comfortable to the body.
\*Notavailable for compact cassette
Wide Range Of Swing Angle Easyto Clean Filter
Arc louver swingangle,range from O-85°, sendsoftairtoanycornerofthe roomeasily.
The filter is very easy to disassemble and clean, keeping the air healthyall the time.
1200mm Water Pump Lift
The Cassette has a built-in water pump,the maximum lift can reach 12oomm,which is conducive to the installation of drain pipes.
Fresh Air
Take in outdoor fresh air,ensure that the indoorair is freshandcirculated.Maxfreshairvolume 1 5 %
2 Direction Drainage
Condensingwatercan be drained their from left or from right.
3D AirFlow
Power Off Memory
1 0 4 ^ { \circ } wide range of air flow.
Withunique swing design,to achieve 3D air supply.
During the operation of the air conditioner, if the power iscut off then come again, thedevicewill work as the previousmodeand setting temperature.
IOC Platform
Empowering commercial buildings& industrial parks,buildingan integrated control ^ + energysupervision ^ + split billing
01.Product Overview
Management Layer (Software platform)
Control Layer (Smart gateway)
02.Key Features
田
ComprehensiveCentralizedControl
Remote Monitoring VRF/LCAC /Modular, Batch On/Off,group management.
Individual Billing System
VRF professional billling, tenant fullifecycle management, periodic billing. \*Billing only available for VRF system
03.Flexible Deployment Modes
Smart Schedule Management
Timed automatic operation, ordinary/priorityschedule settings.
INVOE国
Data O&M&FaultAnalysis
Real-timeenergydatacollection, automaticcurvegeneration, fault alarm statistics.
04.Powerful Access Capacity (Single Gateway)
VRF:1024Indoor Units LCAC:255 Units Modular:247Sets
Optional Accessories
Wired Control
Central Controller
RemoteController
WiFi Control (Optional)
Condenser
1
Panels
(Cassette optional)
Water Pump (Duct optional)
Detector (Optional) (foraftersalesservice)
#
Multiple Control Modes
Various ofcontrollers meets diferentusers’demand.Including wired controler,remotecontroller,APPcontrol, central control and BMS control.
| Central Controller | Basic routine control,group management,schedule management,abnormal operation monitoring, energy-savingstrategy formulation,and fault tracing. |
| IOC | hepoweuti |
| 3rd BMS Control | The Modbus port on the PCB,allows up to 255 AC units connecting with the 3rd party BMS (BuildingManagementSystem). |
| Wifi Module/ WiFi Controller | These optional WiFi accessories allows smart-phone control via TCL APP or TUYA APP. |
| Voice Controller | Off-line speech recognition technology allows user control units by just speaking (Only English now,partial modelsavailable) |
| AC Detector | This inteligent detectoris used for aftersales service,with portable sizea Service Asist APP,to inquire parametersquicklyand troubleshooting. |
GDTCL INTELLIGENTHEATING&VENTILATING EQUIPMENTCO.,LTD.Address: No.7 Yuanlin Road, Nantou, Zhongshan,Guangdong,PR ChinaWeb:cac.tcl.com E- mail:hvac@tcl.com
TCL CAC TCL CAC \circledast TCL CAC 回 HVAC-TCL TCL-CAC