NOAHI
SUSTAINABILITYISINOURNATURE
Heat pumps for an energy-efficient everyday life and a better world
TICA
INTRODUCTION
Since the introduction of TlCA's first air-cooled heat pump at the end of the last century, we have been deeply committed to heat pump technology for nearly 30 years.With the continuous advancement of refrigerants,TlCA has once again initiated innovations in heat pump systems.With the NOAH series,TICA was one of the first manufacturers to optimally implement the environmentally friendlyand highly efficient properties of the refrigerant R290,thereby expanding the potential of this refrigerant.
LOW-CARBON
One Ton Of \mathsf { C O } _ { 2 } Is Equivalent To:
Building A Sustainable Environment
For a house with a living space of 18O square meters, a family of three can be heated with conventional radiators:
Replacing a gas-fired boiler with a TICA heat pump will reduce your emissions by an average of 12261kg \mathsf { C O } _ { 2 } per year.
Replacing an oil-fired boiler with a TICA heat pump will reduce your emissions by an average of 17113 kg \mathsf { C O } _ { 2 } per year.
R290
Brings unbeatable benefits to our heat pumps:
The R290 heat pump features a SCOP of up to 4.9, ensuring high energy efficiency and reduced running costs.Operating between - 2 5 ^ { \circ } \mathsf { C } and + 4 6 ^ { \circ } C , it provides excellent hotwatercomfortand legionella protection withouta backup heater.Witha GWP of just3,itoffers aneco-friendly heating solution,balancing minimal environmental impactwithoptimal performance.
日 8 months housumold electricty 回 380L gasoline 神 100m² mixed forest L 7500km bycar Y 5000km economical flight 红 27000km bytrain
What is GWP ?
GWP is a comparative value that indicates the greenhouse effect of a greenhouse gas to be released into the environment. The higher the value, the worse the impact on the climate.
Exemplary GWPs of some refrigerants:
Exemplary calculation:
R410A 1 . 8 \mathsf {kg } of R410A×2088 GWP =3760 kg CO2
The value indicates the amount of \mathsf { C O } _ { 2 } which has an equal global warming effect.
To calculate the \mathsf { C O } _ { 2 } impact of arefrigerant, the amount contained in the heat pump is multiplied by its GWP value.
13-hourflightfromLondontoKualaLumpur
R290 (NOAH]
0 . 6 ~ \mathsf {kg } of { \mathsf { R } } 2 9 0 { x } 3 \ { \mathsf { G W P } } = 1 . 8 \ { \mathsf {kg } } \ { \mathsf { C O } } _ { 2 }
15kmdrivebycar
O
R290
ECOfriendily Natural refrigerant GWP3
TICA's cutting-edge heat pump technology using natural refrigerant (R290) is the best testimony to its future environmental commitment: The same heat pump, using R290, has only 0 . 0 5 % of the greenhouse effect of traditional R410A .
TICA SMART H@ME
Link To The Future
TICA
OPTIMUMPERFORMANCE
With certification from the EU Energy Efficiency Label,this product achieves an \mathsf { A } + + + efficiency rating at water outlet temperatures of 3 5 ^ { \circ } \mathsf { C } and 5 5 ^ { \circ } C .The entire range reachesa peak COP of 5.45 (A35W18), demonstrating top-tier energy efficiency andoperationalexcellence.
PREMIUMCOMFORT
QUIETOPERATION
The use of efficient, low-speed fans and advanced soundproofing measures ensures that the noise from the outdoor unit is reduced to below 30 dBlA).This allows for flexible placement of the external unit without concerns,even in densely populated residential areas,with no adverse effects on you or yourneighbors.
Below 30dB(A)
Test condition:Ambienttemp.(DB/ WB) 7/6°C.Wateroutlet temp.55C
NOAH's noise reduction technology
Theenlarged fanallows for lower rotational speeds,reducingnoise while maintaining efficiency.Combinedwith Panasonic's DC brushlessmotor,itprovidesa quieter,more energy-efficientoperation.
The CFD-optimized, low-resistance air duct designensuresevenairflowdistribution, minimizingairresistance anddelivering quieter,smootherairflow.
With the integration of a shock-absorbing padunder thecompressorandadual-layer chassis,noise reduction beginsat the source, leadingto softer sound output fora more comfortableacousticexperience.
The compressor is enclosed in multiple layers ofsound-absorbingandinsulatingmaterials. Thisincludesenvironmentallyfriendlyflameretardantacousticinsulation andathreelayernoisereductionsystem,ensuringa significantlyquieteroperation.
TICA
SMARTCONTROL
TICA NOAH App - Comprehensive Smart Home Control
The TICA NOAH app offers a new level of control and comfort by making the management of the home automation solution easier. With TlCA's innovative technology. the users have access to:
强
H
Remote management: Control your heat pump from anywhere inreal time.
Smart scene integration:
Programmable scheduling: Automate heating and cooling based on your routine.
Create customized modes for variousscenarios.
品
Energy monitoring:
Track power consumption and manageenergyefficiency.
Fault detection and diagnostics: Getimmediatealertsand run diagnostics remotely.
Multi-device management: Group and control multiple devices with ease.
&
Personalized settings: Adjust user preferences fora tailored experience.
Customer support: Firmware updates:
Access technical help anytime you need it.
Keep your system updated with the latest improvements.
Fosteringabetterlife Limiting the temperature increase to 1.5 °
TICA
SYSTEMSECURITY
R290 Refrigerant - Advanced Safety Solutions
Recognizing the safety differences between R290and refrigerants like R32 or R410A,we have introduced five progressive safety protocols.These measures are specifically designed to minimize accident risks and ensure secure system operation.
TICA NOAH Monobloc Heat Pump Enhanced Safety Innovations
1 Sealed Electric Control Box (IP55)
Featuring a fireproof and explosion-proof control box designed for A3refrigerants,the fullysealed unitprotects electrical components from refrigerant leaks,ensuring enhanced operational safety.
2 Explosion-Proof Electrical Systems
Integrated explosion-proof electrical components eliminate potential ignitionsources,safeguarding the system.
3 ReducedRefrigerantVolume
\boldsymbol { \varphi 5 } tubing lowers the refrigerant volume,enhancing the overall safety profile of the system.
4 Comprehensive Design with Exhaust Valve
The all-in-one design with an integrated exhaust valve ensures refrigerant stays outside the building,contributing toasafer indoorenvironment.
5 Advanced Leak Detection Systems
Double detection via sensors and advanced algorithms ensuresthatrefrigerant leaksareimmediatelyidentified, optimizing operational safety.
NOA
ABOUTPRODUCTION
MES Full Life Cycle Management System
Starting from the raw materials,the production of all units is controlled by the MES system,making the entire production process more digital and standardized.Until the NOAH heat pump meets you,every process is traceable.
Auto.detection ofwater pressure
Digital monitoring of vacuum pumping
TICA
CERTIFICATIONS
| Model | TUCA040KHLB | TUCA060KHLB | TUCA080KHLB | TUCA100KHLB | TUCA120KHLB | TUCA140KHLB | TUCA160KHLB | |
| Power supply | 220~240V-50Hz | 380~415V-3N-50Hz | ||||||
| Heating(A7W35) | Capacity | W 4500 | 6200 | 8400 | 10000 | 12000 | 14000 | 15000 |
| COP | / 5.42 | 5.25 | 5.15 | 5.05 | 5.15 | 5.05 | 5.00 | |
| Capacity | W 4500 | 6000 | 8000 | 10000 | 12000 | 14000 | 15000 | |
| Heating(A7W45) Heating(A7W55) | COP | / 4.20 | 4.05 | 3.90 | 3.65 | 3.90 | 3.75 | 3.60 |
| Capacity | W 4600 | 6200 | 8000 | 9500 | 12000 | 14000 | 15000 | |
| COP | / 3.40 | 3.35 | 3.30 | 3.20 | 3.30 | 3.20 | 3.10 | |
| Heating(A2W35) | Capacity | W 4400 | 5600 | 7100 | 8200 | 11000 | 12000 | 13000 |
| COP | / 4.10 | 3.90 | 3.85 | 3.65 | 3.75 | 3.65 | 3.50 | |
| Capacity | W 4500 | 5800 | 7200 | 8000 | 10500 | 11500 | 12800 | |
| Heating(A-7W35] Cooling(A35W18] | COP | 3.20 | 2.95 | 3.10 | 2.85 | 3.10 | 3.00 | 2.85 |
| Capacity | W 4300 | 5600 | 7000 | 8600 | 12000 | 140000 | 16000 | |
| EER | / 5.20 | 4.71 | 4.95 | 4.50 | 4.60 | 4.30 | 4.00 | |
| Cooling(A35W7) | Capacity | W 4100 3.42 | 5600 | 6800 | 7600 | 12000 | 13500 | 14500 |
| SCOP | EER | / | 3.01 | 3.21 | 3.04 | 3.05 | 2.90 | 2.75 |
| Average climate,W35 | / A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | A+++ | |
| Average climate,W55 | / A+++ | A+++ | A+++ | A+++ | A++ | A++ | A++ | |
| Net weight | kg 117 | 117 | 132 | 132 | 168 | 168 | 168 | |
| Gross weight Net dimension(W*D*H) | kg 137 | 137 | 152 | 152 | 192 | 192 | 192 | |
| Packing dimension(W*D*H) | mm 110Ox458x945 118Ox60Ox1115 | 110Ox458×945 118Ox60Ox1115 | 110Ox458×945 118Ox60Ox1115 | 110Ox458×945 | 110Ox458x1520 | 110Ox458x1520 | 110Ox458x1520 | |
| Erp sound power level | mm 55 | 55.5 | 56 | 118Ox60Ox1115 57.5 | 1180x60Ox1705 60 | 118Ox60Ox1705 | 118Ox60Ox1705 | |
| Refrigerant | dB | R290/3 | 61 | 62 | ||||
| Type/GWP | 0.51 | R290/3 0.51 | R290/3 0.80 | R290/3 0.80 | R290/3 | R290/3 | R290/3 | |
| Charge | kg | 1.1 | 1.1 | 1.1 | ||||
| Cooling Heating | °℃ 5~46 °℃ | 5~46 | 5~46 | 5~46 | 5~46 | 5~46 | 5~46 | |
| Operating ambient temperature | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | |
| DHW | ℃ -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | -25~43 | |
| Cooling | °℃ 5~25 | 5~25 | 5~25 | 5~25 | 5~25 | 5~25 | 5~25 | |
| Heating | ℃ | 22~80 | 22~80 | 22~80 | 22~80 | 22~80 | 22~80 | |
| Water setting temperature | DHW | 22~80 ℃ 20~75 | 20~75 | 20~75 | 20~75 | 20~75 | 20~75 | 20~75 |