Chapter I Overview
1.1 Working principle
1.2 Features
1.3 Safety and protection
Chapter II Performance Indicators
2.1 Reference conditions
2.2 Accuracy and repeatability
2.3 Liquid flow
2.4 Zero stability
2.5 Range ratio
2.6 Process pressure grade
2.7 Secondary pressure-resistant enclosure
Chapter III Working Conditions
3.1 Ambient conditions
3.2 Ambient temperature
3.3 Process temperature
3.4 Process pressure influence
Chapter IV Converter
4.1 Converter CFT100
Chapter V Structural Parameters
5.1 Structural material
5.2 Dimension parameters
Ordering Information
Chapter I Overview
This product is based on Coriolis principle. The
flow tube through which the medium flows vibrates, thus
causing Coriolis effect. The sensor can calculate the
mass flow and density of the fluid by detecting and
analyzing the changes of frequency, phase difference and
amplitude of the flow tube.
See Fig. 1.
1.1 Working principle
The vibration frequency of the measuring tube of
mass flowmeter changes with the density of the medium
in the tube. By measuring the resonance frequency of the
vibrating tube, the density of the medium can be
obtained.
There is a precise temperature sensor inside the
mass flowmeter, which can directly measure the
temperature of the medium and output it. At the same
time, temperature can also be used for internal
compensation flow and density measurement.
1.2 Features
• Double U-shaped measuring tube, with high
sensitivity.
• The converter is equipped with high-performance
microprocessor and OLED display screen, and
convenient and rapid setting of the parameters.
• The converter has self-checking and selfdiagnosis functions.
• The measurement is not affected by changes in
fluid density, viscosity and temperature.
• The product is not affected by installation and
environment, and can maintain long-term stability.
•The installation is simple, and straight pipe section
and rectification are not required.
• High-temperature, ultra-low-temperature and
high-pressure applications are allowed.
• Ex explosion-proof type can be used in dangerous
places.
The design, production, test, verification,
transportation and storage of mass flowmeters of
Chongqing Chuanyi Automation Co., Ltd. Flowmeter
Branch shall be implemented according to the national
standard GB/T 31130-2014 Coriolis Mass Flow Meter.
Our Coriolis mass flowmeters have excellent flow
and density measurement performance, and can provide
stable and accurate measurement results in liquid, gas
and slurry flow measurement.
• Accurate multi-parameter measurement, including
mass flow, volume flow, density and temperature
measurement.
01 Outlet detection
Inlet detection
Phase
No.flow
Inlet detection
Phase
With flow
Phase differenceNo.flow
Fig. 1 Measurement Principle of Mass Flowmeter
1.3 Safety and protection
• Converter certificate:
CFT100 explosion-proof mark: Ex d[ib] IIB T4 Gb
• Sensor certificate:
CFS series explosion-proof mark: Ex ib IIB/IIC T6...T1 Gb
IP grade: IP67
Chapter II Performance Indicators
2.1 Reference conditions
2.2 Accuracy and repeatability
2.2.1 Accuracy and repeatability of liquid measurement
±0.1% ±0.15% ±0.2% ±0.5%
±0.05% ±0.075% ±0.1% ±0.25%
±0.002
±0.001
±1
±0.2
2.2.2 Accuracy and repeatability of gas measurement
±0.5%
±0.25%
±0.75%
±0.35%
±1
±0.2
02
Reference conditions of instrument measurement performance: Water temperature is 15-25°C and water pressure
is 0.2-0.3 MPa.
Performance & specification Option 1 Option 2 Option 3 Option 4
Mass flow accuracy
Mass flow repeatability
Density accuracy g/cm3
Density repeatability g/cm3
Temperature accuracy°C
Temperature repeatability°C
Performance&specification Option 1 Option 2
Mass flow accuracy
Mass flow repeatability
Temperature accuracy°C
Temperature repeatability°C
03 2.3 Liquid flow
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
DN3
DN6
DN15
DN20
DN25
DN40
DN50
DN80
DN100
DN150
360
1200
4200
7200
12000
32000
60000
180000
300000
600000
2.4 Zero stability
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
DN3
DN6
DN15
DN20
DN25
DN40
DN50
DN80
DN100
DN150
0.01
0.06
0.13
0.46
0.71
1.7
2.4
8.2
12.3
22
Model Caliber Maximum flow rate kg/h
Model Caliber Zero stability kg/h
04
2.5 Range ratio
The following diagram shows an example of measurement characteristics under various flow conditions. If the
flow requires a large range ratio (greater than 20:1), the zero stability value may be affected by the fluid conditions and
the instruments used, thus affecting the performance.
2.6 Process pressure grade
The maximum working pressure of the sensor indicates the highest process pressure grade that can be achieved by
a given sensor. The process connection type as well as the ambient temperature and process medium temperature may
reduce this level.
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
4.0
11
11
25
25
11
11
11
11
11
11
A. Accuracy, %
B. Flow, %
Model
Maximum working pressure
Standard type MPa High-pressure type Mpa
05 2.7 Secondary pressure-resistant enclosure
The mass flowmeter sensor enclosure can realize secondary pressure resistance and protection, and prevent
dangerous media from leaking to the external environment to cause more serious accidents.
It meets the requirements of GB/T 20801 Pressure Piping Code - Industrial Piping and GB 50316 Design Code for
Industrial Metallic Piping.
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
3.1
3.1
2.9
2.5
2.1
2.0
1.8
1.5
1.3
1.1
Model Maximum enclosure pressure Mpa
Note: When the operating temperature is too high, the instrument needs to be depressurized for use. Please
consult the sales representative for details.
06
Atmospheric pressure: 85kPa 106kPa
Ambient temperature: See Clause 3.2
Relative humidity: 5%~95% (non-condensing)
-70 ~ +200°C
-200 ~ +60°C
-40 ~ +300°C
The working environment of the converter shall meet the
following requirements.
The process pressure influence is defined as the
change of mass flow and density accuracy of the sensor
caused by the deviation of process pressure from the
nominal pressure. The influence can be corrected by
dynamic pressure input or fixed instrument coefficient.
Consult the sales representative for details.
3.4 Process pressure influence
For mass flow measurement, the influence of
process temperature is defined as the change of sensor
flow accuracy specification due to the deviation of
process temperature from the calibration temperature.
For density measurement, the influence of process
temperature is defined as the change of density accuracy
specification due to the deviation of process temperature
from the calibration temperature.
The zero-point calibration and intelligent
instrument self-calibration tools can be used to correct
all influence of process temperature.
3.3 Process temperature
Chapter III Working Conditions
3.1 Ambient conditions
3.2 Ambient temperature
Generally, the sensor can be used in the medium
temperature range shown in the table below.
Sensor type Temperature range
Universal type
Cryogenic type
High-temperature type
Components Category Temperature
range
Converter Ambient
temperature -40 ~ +60 °C
07 Chapter IV Converter
C F T 1 0 0 i s a n e l e c t r o n i c s y s t e m w i t h
microprocessor as the core. It can provide driving force
for the sensor and convert the sensor signal into mass
flow signal and other signals. The brand-new digital
signal processing technology and all-digital driving
technology are adopted to greatly improve the
processing of micro-flow micro-signal of flowmeter, and
realize rapid signal processing and rapid response.
CFT100 converter is equipped with the industryleading large OLED screen, with clear display, and
ensures to continue to provide customers with stable
parameter display and service at the low temperature of -
40°C.
4.1 Converter CFT100 ●Typical measurement parameters
Mass flow/total
Volume flow/total
Density
Temperature
● Intelligent functions
Instrument intelligent diagnosis
Bi-directional measurement
Coded lock
● Power options
85~265 VAC 50/60 Hz 10W
24VDC 10W
● Electrical interface
2 female threaded interfaces: NPT1/2
2 female threaded interfaces: M20
● Signal output (optional)
4~20mA current loop
0~10kHz frequency
Modbus RS485
HART
FF
● HMI
Chinese/English display
Status indication
Independent light-sensitive isolation button
08
5.1 Structural material
5.2 Dimension parameters
B
A
B
C
D
A
C
D
A
B
C
DN3-DN40 DN50-DN150
DN20
D
Chapter V Structural Parameters
Category Structure Material
Wetted part
Enclosure
Measuring tube
Shunt support
Flange
Sensor
Converter
Junction box
Optional 316L stainless steel/Hastelloy
Optional 304 stainless steel /316L stainless steel/Hastelloy
Optional 304 stainless steel /316L stainless steel/Hastelloy
304 stainless steel or 316L stainless steel
Cast aluminum alloy (coated with epoxy polyurethane)
Cast aluminum alloy (coated with epoxy polyurethane)
09 Overall dimensions of sensor
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
Overall dimensions of CFT100 converter
132 174 170
Model Type Caliber
Dimension (mm)
A B C D
Triangle
Triangle
Triangle
U
Triangle
Triangle
U
U
U
U
DN3
DN6
DN15
DN20
DN25
DN40
DN50
DN80
DN100
DN150
196
163
188
332
211
262
552
731
755
1020
255
274
339
401
538
636
711
893
1162
1322
243
235
293
301
448
576
506
653
709
907
64
54
162
101
117
227
230
278
345
393
Note: Refer to HG/T20615-2009 PN40 RFWN flange for the above dimensions. Please
consult the sales representative for details.
10
Split installation dimensions of converter
Note: The thickness of the support plate is 3mm.
11 Product main name
□□□
Sensor model
□
Sensor characteristics
□
Accuracy class □
Process
connection type
□
MFMC
B
C
S
1
1
2
3
4
5
6
7
8
9
A
B
S
Sensor accessory
□
Y
X
Converter model □
CFT100
M
N
S
Power supply mode
□
1
2
Ordering Information
Selection Table of MFM-C Series Mass Flowmeters
Option description Code Code information description
Diameter: DN3-DN300; three digits: the first and second digits of DN and
the number of zeros following the first two digits (unit: mm).
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
(0 ~ 110)kg/h
(0 ~ 1200)kg/h
(0 ~ 3000)kg/h
(0 ~ 7200)kg/h
(0 ~ 12000)kg/h
(0 ~ 32000)kg/h
(0 ~ 60000)kg/h
(0 ~ 180000)kg/h
(0 ~ 300000)kg/h
(0 ~ 600000)kg/h
316L Temperature-resistant 200 body 316L cover 304
316L Temperature-resistant 300 body 316L cover 304
Special order (special material: 304L, Hastelloy C22, duplex stainless steel, tantalum)
Class 0.5
GB/T 9115-2010 RF welding neck flange 4MPa WN-RF
GB/T 9115-2010 RF welding neck flange 1.6MPa WN-RF
GB/T 9115-2010 RF welding neck flange 6.3MPa WN-RF
HG/T 20615-2009 RF welding neck flange Class300 WN-RF
ASME B16.5-2009 RF welding neck flange Class150 WN-RF
ASME B16.5-2009 RF welding neck flange Class300 WN-RF
HG/T 20592-2009 RF welding neck flange 4MPa WN-RF
HG/T 20592-2009 RF welding neck flange 1.6MPa WN-RF
ASME B16.5-2009 RF welding neck flange Class600 WN-RF
Threaded connection (DN15 and DN25 only)
Threaded connection (DN15 and DN20 only) High-pressure type
Special order
Heat tracing jacket
XXX
Chinese/English switching interface, IP67, Exd ib IIB T1-T6 Gb, shunt type
M20
1/2NPT
T: Special order
18VDC-36VDC
85VAC-265VAC
Electrical interfaceof
converter powersupply
and signal line□
12
Measurement
mode□
A
F
Y
F
Installation method
□
Annex
□
Certification
□
Communication
and data acquisition
mode□
1
2
3
4
S
0
1
2
3
S
00
0
1
2
3
Cable□
Option description Code Code information description
Active circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+RS485
Active circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+HART
Passive circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+RS485
Passive circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+HART
Special order
Standard measurement type
Undefined
Integrated type (only for DN50 and above)
Split type
N/A
Carbon steel flange, bolt and nut, and metal wound gasket
304 stainless steel flange, bolt and nut, and metal wound gasket
316L stainless steel flange, bolt and nut, and metal wound gasket
9: Special order
The cable length increases every 5m, with the default of 00(3m) and the
longest of 95m.
Factory verification certificate
Verification certificate of national verification institution
Verification certificate of third-party designated organization
XXXX
13 Product main name
□□□
Sensor model
□
Sensor characteristics
□
Accuracy grade
□
MFMN
B
C
S
2
3
Diameter: DN3-DN300; three digits: the first and second digits of DN and
the number of zeros following the first two digits (unit: mm).
Process
connection type
□
1
2
3
4
5
6
7
8
9
A
B
S
Sensor accessory Y
X
Converter model□ CFT100
Electrical interface of
converter power supply
and signal line□
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
(0~110)kg/h
(0~1200)kg/h
(0~3000)kg/h
(0~7200)kg/h
(0~12000)kg/h
(0~32000)kg/h
(0~60000)kg/h
(0~180000)kg/h
(0~300000)kg/h
(0~600000)kg/h
Class 0.2
Class 0.15
M
N
S
M20
1/2NPT
T: Special order
Communication and
data acquisition mode
□
1
2
18VDC-36VDC
85VAC-265VAC
Selection Table of MFM-N Series Mass Flowmeters
Option description Code Code information description
316L Temperature-resistant 200 body 316L cover 304
316L Temperature-resistant 300 body 316L cover 304
Special order (special material: 304L, Hastelloy C22, duplex stainless steel, tantalum)
GB/T 9115-2010 RF welding neck flange 4MPa WN-RF
GB/T 9115-2010 RF welding neck flange 1.6MPa WN-RF
GB/T 9115-2010 RF welding neck flange 6.3MPa WN-RF
HG/T 20615-2009 RF welding neck flange Class300 WN-RF
ASME B16.5-2009 RF welding neck flange Class150 WN-RF
ASME B16.5-2009 RF welding neck flange Class300 WN-RF
HG/T 20592-2009 RF welding neck flange 4MPa WN-RF
HG/T 20592-2009 RF welding neck flange 1.6MPa WN-RF
ASME B16.5-2009 RF welding neck flange Class600 WN-RF
Threaded connection (DN15 and DN25 only)
Threaded connection (DN15 and DN20 only) High-pressure type
Special order
Heat tracing jacket
□ XXX
Chinese/English switching interface, IP67, Exd ib IIB T1-T6 Gb, shunt type
14
Measurement mode
□
A
F
Y
F
Installation method
□
Annex
□
Certification
□
Standard measurement type
Undefined
Integrated type (only for DN50 and above)
Split type
Communication
and data acquisition
mode
1
2
3
4
S
Active circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+RS485
Active circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+HART
Passive circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+RS485
Passive circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+HART
Special order
0
1
2
3
S
00
0
1
2
3
Cable□
Option description Code Code information description
□
N/A
Carbon steel flange, bolt and nut, and metal wound gasket
304 stainless steel flange, bolt and nut, and metal wound gasket
316L stainless steel flange, bolt and nut, and metal wound gasket
9: Special order
The cable length increases every 5m, with the default of 00(3m) and the
longest of 95m.
Factory verification certificate
Verification certificate of national verification institution
Verification certificate of third-party designated organization
XXXX
15 Option description
Product main name
□□□
Sensor model
□
Sensor characteristics
□
Accuracy grade
□
B
C
S
4
1
2
3
4
5
6
7
8
9
A
B
S
Sensor accessory
□
Y
X
Converter model□ CFT100
Electrical interface of
converter power supply
and signal line □
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
(0~110)kg/h
(0~1200)kg/h
(0~3000)kg/h
(0~7200)kg/h
(0~12000)kg/h
(0~32000)kg/h
(0~60000)kg/h
(0~180000)kg/h
(0~300000)kg/h
(0~600000)kg/h
Chinese/English switching interface, IP67, Exd ib IIB T1-T6 Gb, shunt type
M
N
S
M20
1/2NPT
T: Special order
Power supply
mode□
1
2
18VDC-36VDC
85VAC-265VAC
MFMP
Class 0.1
Selection Table of MFM-P Series Mass Flowmeters
Code Code information description
Diameter: DN3-DN300; three digits: the first and second digits of DN and
the number of zeros following the first two digits (unit: mm).
316L Temperature-resistant 200 body 316L cover 304
316L Temperature-resistant 300 body 316L cover 304
Special order (special material: 304L, Hastelloy C22, duplex stainless steel, tantalum)
Process
connection type
□
GB/T 9115-2010 RF welding neck flange 4MPa WN-RF
GB/T 9115-2010 RF welding neck flange 1.6MPa WN-RF
GB/T 9115-2010 RF welding neck flange 6.3MPa WN-RF
HG/T 20615-2009 RF welding neck flange Class300 WN-RF
ASME B16.5-2009 RF welding neck flange Class150 WN-RF
ASME B16.5-2009 RF welding neck flange Class300 WN-RF
HG/T 20592-2009 RF welding neck flange 4MPa WN-RF
HG/T 20592-2009 RF welding neck flange 1.6MPa WN-RF
ASME B16.5-2009 RF welding neck flange Class600 WN-RF
Threaded connection (DN15 and DN25 only)
Threaded connection (DN15 and DN20 only) High-pressure type
Special order
Heat tracing jacket
XXX
16
Measurement mode
□
A
F
Y
F
Installation method
□
Annex
□
Certification
□
Standard measurement type
Undefined
Integrated type (only for DN50 and above)
Split type
Communication
and data acquisition
mode
□
1
2
3
4
S
0
1
2
3
S
00
0
1
2
3
Cable□
Option description Code Code information description
Active circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+RS485
Active circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+HART
Passive circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+RS485
Passive circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+HART
Special order
N/A
Carbon steel flange, bolt and nut, and metal wound gasket
304 stainless steel flange, bolt and nut, and metal wound gasket
316L stainless steel flange, bolt and nut, and metal wound gasket
9: Special order
The cable length increases every 5m, with the default of 00(3m) and the
longest of 95m.
Factory verification certificate
Verification certificate of national verification institution
Verification certificate of third-party designated organization
XXXX
17 Product main name
□□□
Sensor model
□
Sensor characteristics
□
Accuracy grade
MFML
D
S
(0~110)kg/h
(0~1200)kg/h
(0~3000)kg/h
(0~7200)kg/h
(0~12000)kg/h
(0~32000)kg/h
(0~60000)kg/h
(0~180000)kg/h
(0~300000)kg/h
(0~600000)kg/h
Process connection
type □
1
2
3
4
□
CFS003
CFS006
CFS015
CFS020
CFS025
CFS040
CFS050
CFS080
CFS100
CFS150
1
2
3
4
5
6
7
8
9
A
B
S
Converter model□ CFT100
Electrical interface of
converter power supply
and signal line□
M
N
S
Power supply mode
□
1
2
Selection Table of MFM-L Series Mass Flowmeters
Option description Code Code information description
Diameter: DN3-DN300; three digits: the first and second digits of DN and
the number of zeros following the first two digits (unit: mm).
316L Cryogenic-200cC (body 316L, cover 304)
Special order (special material: 304L, Hastelloy C22, duplex stainless steel, tantalum)
Class 0.5
Class 0.2
Class 0.15
Class 0.1
GB/T 9115-2010 RF welding neck flange 4MPa WN-RF
GB/T 9115-2010 RF welding neck flange 1.6MPa WN-RF
GB/T 9115-2010 RF welding neck flange 6.3MPa WN-RF
HG/T 20615-2009 RF welding neck flange Class300 WN-RF
ASME B16.5-2009 RF welding neck flange Class150 WN-RF
ASME B16.5-2009 RF welding neck flange Class300 WN-RF
HG/T 20592-2009 RF welding neck flange 4MPa WN-RF
HG/T 20592-2009 RF welding neck flange 1.6MPa WN-RF
ASME B16.5-2009 RF welding neck flange Class600 WN-RF
Threaded connection (DN15 and DN25 only)
Threaded connection (DN15 and DN20 only) High-pressure type
Special order
Chinese/English switching interface, IP67, Exd ib IIB T1-T6 Gb, shunt type
M20
1/2NPT
T: Special order
18VDC-36VDC
85VAC-265VAC
18
Measurement mode
□
A
F
Y
F
0
1
2
3
S
00
0
1
2
3
Installation method
□
Annex
□
Certification
□
Standard measurement type
Undefined
Communication
and data acquisition
mode□
1
2
3
4
S
Cable□
Option description Code Code information description
Active circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+RS485
Active circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+HART
Passive circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+RS485
Passive circulating current (4 ~ 20)mA+frequency (0 ~ 10)kHz+HART
Special order
Integrated type (only for DN50 and above)
Split type
N/A
Carbon steel flange, bolt and nut, and metal wound gasket
304 stainless steel flange, bolt and nut, and metal wound gasket
316L stainless steel flange, bolt and nut, and metal wound gasket
9: Special order
The cable length increases every 5m, with the default of 00(3m) and the
longest of 95m.
Factory verification certificate
Verification certificate of national verification institution
Verification certificate of third-party designated organization
XXXX
19
SIC ACCOMPANIES CUSTOMERS AND
CUSTOMERS IN THE HEART OF SIC
CHONGQING CHUANYI AUTOMATION CO., LTD. FLOWMETER BRANCH
Address: No. 61, Middle Section of Huangshan Avenue, New North Zone, Chongqing, China
Tel.: 023-67032678 67032666 67032667 67032668 67032669
Fax: 023-67032676 Postal code: 401121
Website: www.sicflow.com.cn
Email: flowmaster@sicc.com.cn flowmaster@sicflow.com.cn
Address: No. 61, Middle Section of Huangshan Avenue,
New North Zone, Chongqing, China
Sales hotline: 023-67032678
Tel.: 023-67032666
Technical support: 023-67032695 023-67032667
Fax: 023-67032676
Postal code: 401121
Website: www.cqcy.com
Email: flowmaster@sicc.com.cn
flowmaster@sicflow.com.cn
March 2023, First Edition It is subject to change without notice!
SIC ACCOMPAIES CUSTOMERS AND CUSTOMERS IN THE HEART OF SIC
QR code of Chuanyi
Flowmeter
Please scan the QR code
of Chongqing Chuanyi