TableofContents
ChapterIOverview 1
1.1 Working principle
1.2 Features 5
1.3Safetyand protection.. 6
ChapterIIPerformance Indicators 12
2.1 Reference conditions 16
2.2 Accuracy and repeatability 23
2.3Liquid flow 27
2.4 Zero stability· 31
2.5 Range ratio 35
2.6 Process pressure grade 37
2.7 Secondary pressure-resistant enclosure 40
Chapter III Working Conditions 45
3.1Ambient conditions 54
3.2Ambient temperature 57
3.3Process temperature 61
3.4 Process pressure influence 61
ChapterIVConverter 63
4.1 Converter CFT100 64
ChapterVStructural Parameters 66
5.1 Structural material 68
5.2Dimension parameters 68
Ordering Information 69
ChapterIOverview
1.1 Working principle
This product is based on Coriolis principle.The flowtubethroughwhich themediumflowsvibrates,thus causing Coriolis effect. The sensor can calculate the massflowanddensityofthefluidbydetectingand analyzing the changes of frequency,phase difference and amplitudeof the flowtube.
See Fig. 1.
The vibration frequency of the measuring tube of mass flowmeterchangeswith thedensityof themedium in the tube.By measuring the resonance frequency of the vibrating tube,the density of the medium can be obtained.
There is a precise temperature sensor inside the mass flowmeter,which can directlymeasure the temperature of themedium and outputit.At the same time,temperature can also be used for internal compensation flowand densitymeasurement.
·Double U-shaped measuring tube,with high sensitivity.
·The converter is equipped with high-performance microprocessor and OLED display screen,and convenientand rapid settingof the parameters.
·The converter has self-checking and selfdiagnosis functions.
·The measurement is not affected by changes in fluid density, viscosity and temperature.
·The product is not affected by installation and environment,and can maintain long-term stability.
·The installation is simple,and straight pipe section and rectification are not required.
·High-temperature,ultra-low-temperature and high-pressure applications are allowed.
·Ex explosion-proof type can be used in dangerous places.
The design,production,test,verification, transportation and storage of mass flowmeters of Chongqing Chuanyi Automation Co.,Ltd. Flowmeter Branch shall be implemented accordingto the national standardGB/T31130-2014CoriolisMassFlowMeter.
1.2 Features
OurCoriolismass flowmeters have excellent flow and densitymeasurement performance,and can provide stable and accurate measurement results in liquid,gas and slurry flowmeasurement.
·Accurate multi-parameter measurement, including mass flow,volume flow,density and temperature measurement.
1.3Safetyand protection
·Converter certificate:
CFT100 explosion-proof mark:Ex d[ib] IIB T4 Gb
·Sensor certificate:
CFS series explosion-proof mark:Ex ib IIB/IIC T6...T1 Gb
IP grade:IP67
ChapterIIPerformanceIndicators
2.1Referenceconditions
Reference conditions of instrument measurement performance:Water temperature is 1 5 . 2 5 ^ { \circ } { C } and water pressure .i 0 . 2 { - } 0 . 3 { M P a }
2.2Accuracyandrepeatability
| Performance& specification | Option1 | Option 2 | Option 3 | Option 4 |
| Mass flow accuracy | ±0.1% | ±0.15% | ±0.2% | ±0.5% |
| Mass flow repeatability | ±0.05% | ±0.075% | ±0.1% | ±0.25% |
| Density accuracy g/cm3 | ±0.002 | |||
| Density repeatabilityg/cm3 | ±0.001 | |||
| Temperature accuracyC | ±1 | |||
| Temperature repeatabilityC | ±0.2 | |||
| Performance&specification | Option 1 | Option 2 |
| Mass flowaccuracy | ±0.5% | ±0.75% |
| Mass flow repeatability | ±0.25% | ±0.35% |
| Temperature accuracyC | ±1 | |
| Temperature repeatabilityC | ±0.2 | |
2.3Liquid flow
| Model | Caliber | Maximum flowratekg/h |
| CFS003 | DN3 | 360 |
| CFS006 | DN6 | 1200 |
| CFS015 | DN15 | 4200 |
| CFS020 | DN20 | 7200 |
| CFS025 | DN25 | 12000 |
| CFS040 | DN40 | 32000 |
| CFS050 | DN50 | 60000 |
| CFS080 | DN80 | 180000 |
| CFS100 | DN100 | 300000 |
| CFS150 | DN150 | 600000 |
2.4 Zero stability
| Model | Caliber | Zerostability kg/h |
| CFS003 | DN3 | 0.01 |
| CFS006 | DN6 | 0.06 |
| CFS015 | DN15 | 0.13 |
| CFS020 | DN20 | 0.46 |
| CFS025 | DN25 | 0.71 |
| CFS040 | DN40 | 1.7 |
| CFS050 | DN50 | 2.4 |
| CFS080 | DN80 | 8.2 |
| CFS100 | DN100 | 12.3 |
| CFS150 | DN150 | 22 |
2.5 Range ratio
The following diagram shows an example of measurement characteristics under various flow conditions.If the flowrequiresalargerangeratio(greaterthan2O:1),thezero stabilityvaluemaybeaffctedbythefluidconditionsand the instruments used,thus affecting the performance.
A.Accuracy, % B.Flow, % (204号
2.6Process pressure grade
The maximum working pressure of the sensor indicates the highest process pressure grade that canbe achieved by agiven sensor.The process connection type as wellas theambient temperature and process medium temperature may reduce thislevel.
| Model | Maximum working pressure | |
| StandardtypeMPa | High-pressure type Mpa | |
| CFS003 | 4.0 | 11 |
| CFS006 | 4.0 | 11 |
| CFS015 | 4.0 | 25 |
| CFS020 | 4.0 | 25 |
| CFS025 | 4.0 | 11 |
| CFS040 | 4.0 | 11 |
| CFS050 | 4.0 | 11 |
| CFS080 | 4.0 | 11 |
| CFS100 | 4.0 | 11 |
| CFS150 | 4.0 | 11 |
2.7 Secondary pressure-resistant enclosure
The mass flowmeter sensor enclosurecan realize secondary pressure resistance and protection,and prevent dangerous media from leaking to the external environment to cause more serious accidents.
It meetstherequirementsofGB/T20801PressrePipingCode-IndustrialPiping andGB50316Design Code for Industrial Metallic Piping.
| Model | Maximum enclosurepressureMpa |
| CFS003 | 3.1 |
| CFS006 | 3.1 |
| CFS015 | 2.9 |
| CFS020 | 2.5 |
| CFS025 | 2.1 |
| CFS040 | 2.0 |
| CFS050 | 1.8 |
| CFS080 | 1.5 |
| CFS100 | 1.3 |
| CFS150 | 1.1 |
Note:When the operating temperature is too high,the instrument needs to be depressurized for use.Please consult the sales representative for details.
ChapterIIIWorkingConditions
3.1Ambientconditions
Atmospheric pressure:85kPa 106kPa Ambient temperature:See Clause 3.2 Relative humidity: 5 % ~ 9 5 % (non-condensing)
3.2Ambienttemperature
Generally,thesensorcanbeusedinthemedium temperature range shown in the table below.
| Sensor type | Temperature range |
| Universal type | -70~+200℃ |
| Cryogenic type | -200~+60℃ |
| High-temperature type | -40~+300°℃ |
Theworking environment of the converter shall meet the following requirements.
| Components | Category | Temperature |
| Converter | teAmbiente | -40~+60℃ |
3.3Process temperature
Formass flow measurement, the influence of process temperature is defined as the change of sensor flow accuracy specification due to the deviation of process temperature from the calibration temperature.
For density measurement,the influence of process temperature is defined as the change of density accuracy specification due to the deviationof process temperature from the calibration temperature.
The zero-point calibration and intelligent instrument self-calibration toolscan beused to correct all influence of process temperature.
3.4Processpressure influence
The process pressure influence is defined as the change of mass flow and density accuracy of the sensor caused by the deviation of process pressure from the nominal pressure.The influence can be corrected by dynamic pressure input or fixed instrument coefficient. Consult the sales representative for details.
ChapterIVConverter
4.1ConverterCFT100
CFT10o is an electronic system with microprocessor as the core.It can provide driving force for the sensor and convert the sensor signal into mass flow signal and other signals.The brand-new digital signal processing technology and all-digital driving technology are adopted to greatly improve the processing of micro-flow micro-signal of flowmeter,and realize rapid signal processing and rapid response.
CFT100 converter is equipped with the industryleading large OLED screen,with clear display,and ensures to continue to provide customers with stable parameterdisplay and serviceat the lowtemperature of - 4 0 ^ { \circ } { C }
·Typical measurement parameters
Mass flow/total
Volume flow/total
Density
Temperature
·Intelligent functions
Instrument intelligent diagnosis
Bi-directional measurement
Codedlock
·Power options
85\~265VAC50/60Hz10W
24VDC10W
·Electrical interface
2female threaded interfaces:NPT1/2
2female threaded interfaces:M20
· Signal output (optional)
4 { ~ } 2 0 { m A } current loop
0\~10kHz frequency
Modbus RS485
HART
FF
·HMI
Chinese/English display
Status indication
Independent light-sensitive isolation butt
ChapterVStructuralParameters
5.1Structuralmaterial
| Category | Structure | Material |
| Wetted part | Measuringtube | Optional 316L stainless steel/Hastelloy |
| Shunt support | Optional 304 stainless steel/316L stainless steel/Hastelloy | |
| Flange | Optional 304 stainless steel/316L stainless steel/Hastelloy | |
| Enclosure | Sensor | 304 stainless steel or 316L stainless steel |
| Converter | Cast aluminum alloy (coated with epoxy polyurethane) | |
| Junction box | Castaluminum alloy (coated with epoxy polyurethane) |
5.2Dimension parameters
| Model | Type | Caliber | Dimension (mm) | |||
| A | B | C | D | |||
| CFS003 | Triangle | DN3 | 196 | 255 | 243 | 64 |
| CFS006 | Triangle | DN6 | 163 | 274 | 235 | 54 |
| CFS015 | Triangle | DN15 | 188 | 339 | 293 | 162 |
| CFS020 | U | DN20 | 332 | 401 | 301 | 101 |
| CFS025 | Triangle | DN25 | 211 | 538 | 448 | 117 |
| CFS040 | Triangle | DN40 | 262 | 636 | 576 | 227 |
| CFS050 | U | DN50 | 552 | 711 | 506 | 230 |
| CFS080 | U | DN80 | 731 | 893 | 653 | 278 |
| CFS100 | U | DN100 | 755 | 1162 | 709 | 345 |
| CFS150 | U | DN150 | 1020 | 1322 | 907 | 393 |
OveralldimensionsofCFT1ooconverter
Splitinstallationdimensionsofconverter
Note:The thicknessof the supportplateis 3 {mm } 业
OrderingInformation
Selection TableofMFM-CSeriesMassFlowmeters
| Option description | Code | Code informationdescription |
| Product main name □□ | MFMC | Diameter:DN3-DN3oo; three digits:the first and second digits of DN and the number of zeros following the first two digits (unit: mm). |
| Sensor model | CFS003 | (0~110)kg/h |
| CFS006 | (0~1200)kg/h | |
| CFS015 | (0~3000)kg/h | |
| CFS020 | (0~7200)kg/h | |
| CFS025 | (0~12000)kg/h | |
| CFS040 | (0~32000)kg/h | |
| CFS050 | (0~60000)kg/h | |
| CFS080 | (0~180000)kg/h | |
| CFS100 | (0~300000)kg/h | |
| CFS150 | (0~600000)kg/h | |
| Sensorcharacteristics □ | B | 316L Temperature-resistant 200 body 316L cover 304 |
| C | 316LTemperature-resistant 300 body 316L cover 304 | |
| S | Special order(special material:304L,Hastelloy C22,duplex stainless steel,tantalum) | |
| Accuracy class | 1 | Class 0.5 |
| Process | 1 | GB/T9115-2010 RFwelding neck flange 4MPaWN-RF |
| 2 | GB/T9115-2010RFweldingneckflange1.6MPaWN-RF | |
| 3 | GB/T9115-2010RFweldingneckflange6.3MPaWN-RF | |
| 4 | HG/T20615-2009RFweldingneckflangeClass300WN-RF | |
| 5 | ASMEB16.5-2009RFweldingneckflangeClass150WN-RF | |
| 6 | ASMEB16.5-2009RFweldingneckflangeClass300WN-RF | |
| 7 | HG/T20592-2009RFweldingneckflange4MPaWN-RF | |
| 8 | HG/T20592-2009RFweldingneckflange1.6MPaWN-RF | |
| 9 | ASMEB16.5-2009RFweldingneckflangeClass600WN-RF | |
| A | Threaded connection (DN15 and DN25 only) | |
| B | Threaded connection (DN15 and DN20 only) High-pressure type | |
| S | Special order | |
| Y | Heat tracing jacket | |
| □ | X | XXX |
| Converter model Electrical interfaceof | CFT100 M | Chinese/English switching interface,IP67,Exd ibIIBT1-T6Gb,shunt type M20 |
| N | 1/2NPT | |
| S | T: Special order | |
| Power supply mode □ | 1 | 18VDC-36VDC |
| 2 | 85VAC-265VAC |
| Option description | Code | Codeinformationdescription |
| Communication and data acquisition mode□ | 1 | Active circulating current (4~20)mA+frequency (0~10)kHz+RS485 |
| 2 | Active circulating current (4~20)mA+frequency (0~10)kHz+HART | |
| 3 | Passive circulating current (4~20)mA+frequency (0~1O)kHz+RS485 | |
| 4 | Passive circulatingcurrent (4~20)mA+frequency (0~10)kHz+HART | |
| S | Special order | |
| Measurement mode□ | A | Standard measurement type |
| F | Undefined | |
| Installation method □ | Y | Integrated type (only forDN50 and above) |
| F | Split type | |
| Annex □ | 0 | N/A |
| 1 | Carbonsteel flange,boltand nut,and metal wound gasket | |
| 2 | 304stainlesssteel flange,boltand nut,and metal wound gasket | |
| 3 | 316L stainless steel flange,bolt and nut,and metal wound gasket | |
| Cable | S | 9: Special order The cable length increases every 5m,with the default of Oo(3m) and the |
| Certification □ | 00 | longest of 95m. Factory verification certificate |
| 0 1 | Verification certificate of national verification institution | |
| 2 | Verificationcertificate of third-party designated organization | |
| 3 | XXXX |
Selection TableofMFM-NSeriesMassFlowmeters
| Option description | Code | Code information description |
| Product main name | MFMN | Diameter:DN3-DN3oo; three digits:the first and second digits of DN and the number of zeros following the first two digits (unit: mm). |
| Sensor model | CFS003 | (0~110)kg/h |
| CFS006 | (0~1200)kg/h | |
| CFS015 | (0~3000)kg/h | |
| CFS020 | (0~7200)kg/h | |
| CFS025 | (0~12000)kg/h | |
| CFS040 | (0~32000)kg/h | |
| CFS050 | (0~60000)kg/h | |
| CFS080 | (0~180000)kg/h | |
| CFS100 | (0~300000)kg/h | |
| CFS150 | (0~600000)kg/h | |
| Sensor characteristics | B | 316L Temperature-resistant 200 body 316L cover 304 |
| C | 316L Temperature-resistant 3O0 body 316L cover 304 | |
| S | Special order (special material: 3O4L,Hastelloy C22,duplex stainless steel, tantalum) | |
| Accuracy grade □ | 2 | Class 0.2 |
| 3 | Class 0.15 | |
| Process connection type □ | 1 | GB/T9115-2010RFweldingneckflange 4MPaWN-RF |
| 2 | GB/T9115-2010RFwelding neck flange1.6MPaWN-RF | |
| 3 | GB/T9115-2010RFweldingneck flange 6.3MPaWN-RF | |
| 4 | HG/T20615-2009RFweldingneckflangeClass300WN-RF | |
| 5 | ASMEB16.5-2009RFweldingneckflangeClass150WN-RF | |
| 6 | ASMEB16.5-2009RFweldingneck flangeClass300WN-RF | |
| 7 | HG/T20592-2009RFweldingneck flange 4MPa WN-RF | |
| 8 | HG/T20592-2009RFweldingneckflange1.6MPaWN-RF | |
| 9 | ASMEB16.5-2009RF welding neck flange Class600 WN-RF | |
| A | Threaded connection (DN15 and DN25 only) | |
| B | Threaded connection (DN15 and DN20 only) High-pressure type | |
| S | Special order | |
| Y | Heat tracing jacket | |
| Sensor accessory □ | X | XXX |
| Converter model Electrical interface of | CFT100 | Chinese/English switching interface,IP67,Exd ibIIBT1-T6Gb,shunt type |
| M | ||
| N | 1/2NPT | |
| Communicationand data acquisition mode | S | T: Special order 18VDC-36VDC |
| 1 | ||
| 2 | 85VAC-265VAC |
| Option description | Code | Codeinformationdescription |
| Communication and data acquisition mode □ | 1 | Active circulating current (4~20)mA+frequency (0~10)kHz+RS485 |
| 2 | Active circulating current (4~20)mA+frequency (0~10)kHz+HART | |
| 3 | Passive circulatingcurrent(4~20)mA+frequency(0~10)kHz+RS485 | |
| 4 | Passive circulating current(4~20)mA+frequency(0~10)kHz+HART | |
| S | Special order | |
| Measurement mode □ | A | Standard measurement type |
| F | Undefined | |
| Installation method □ | Y | Integrated type (only forDN50 and above) |
| F | Split type | |
| Annex □ | 0 | N/A |
| 1 | Carbonsteelflange,boltand nut,and metal wound gasket | |
| 2 | 304 stainless steelflange,boltand nut,and metalwound gasket | |
| 3 | 316L stainless steel flange,bolt and nut,and metal wound gasket | |
| S | 9:Special order | |
| Cable | 00 | The cable length increases every 5m,with the defaultof Oo(3m) and the longest of 95m. |
| Certification □ | 0 | Factory verificationcertificate |
| 1 | Verification certificate of national verification institution | |
| 2 | Verification certificate of third-partydesignated organization | |
| 3 | XXXX |
Selection TableofMFM-PSeriesMassFlowmeters
| Option description | Code | Code informationdescription |
| Product main name □□□ | MFMP | Diameter:DN3-DN3o0; three digits: the first and second digits of DN and the number of zeros following the first two digits (unit: mm). |
| Sensor model | CFS003 | (0~110)kg/h |
| CFS006 | (0~1200)kg/h | |
| CFS015 | (0~3000)kg/h | |
| CFS020 | (0~7200)kg/h | |
| CFS025 | (0~12000)kg/h | |
| CFS040 | (0~32000)kg/h | |
| CFS050 | (0~60000)kg/h | |
| CFS080 | (0~180000)kg/h | |
| CFS100 | (0~300000)kg/h | |
| CFS150 | (0~600000)kg/h | |
| Sensorcharacteristics □ | B | 316L Temperature-resistant 200 body 316L cover 304 |
| C | 316L Temperature-resistant 300 body 316L cover 304 | |
| S | Special order(special material: 3O4L,Hastelloy C22,duplex stainless steel, tantalum) | |
| Accuracy grade □ | 4 | Class 0.1 |
| Process connection type □ | 1 | GB/T9115-2010RFwelding neck flange4MPaWN-RF |
| 2 | GB/T9115-2010RFwelding neck flange1.6MPaWN-RF | |
| 3 | GB/T9115-2010RFwelding neck flange6.3MPaWN-RF | |
| 4 | HG/T20615-2009RFweldingneck flangeClass300WN-RF | |
| 5 | ASMEB16.5-2009RFweldingneckflangeClass150WN-RF | |
| 6 | ASMEB16.5-2009RFweldingneckflangeClass300WN-RF | |
| 7 | HG/T20592-2009RFweldingneckflange 4MPaWN-RF | |
| 8 | HG/T20592-2009RFweldingneckflange1.6MPaWN-RF | |
| 9 | ASMEB16.5-2009 RF welding neck flange Class600 WN-RF | |
| A | Threaded connection (DN15and DN25 only) | |
| B | Threaded connection (DN15 and DN20 only) High-pressure type | |
| S | Special order | |
| Sensor accessory □ | Y | Heat tracing jacket XXX |
| X | ||
| Converter model | CFT100 | Chinese/English switching interface,IP67,Exd ibIIBT1-T6Gb,shunt type |
| Electrical interface of converter power supply and signal line □ | M | M20 |
| N | 1/2NPT | |
| S | T: Special order | |
| Power supply mode | 1 | 18VDC-36VDC |
| 2 | 85VAC-265VAC |
| Option description | Code | Codeinformationdescription |
| Communication and data acquisition | 1 | Activecirculatingcurrent(4~20)mA+frequency(0~10)kHz+RS485 |
| 2 | Active circulatingcurrent(4~20)mA+frequency(0~10)kHz+HART | |
| 3 | Passive circulating current(4~20)mA+frequency(0~10)kHz+RS485 | |
| 4 | Passive circulating current(4~20)mA+frequency (0~10)kHz+HART | |
| S | Special order | |
| Measurement mode □ | A | Standard measurement type |
| F | Undefined | |
| Installation method □ | Y | Integrated type (only forDN50and above) |
| F | Split type | |
| Annex □ | 0 | N/A |
| 1 | Carbonsteel flange,boltand nut,andmetal wound gasket | |
| 2 | 304 stainless steel flange,bolt and nut,and metal wound gasket | |
| 3 | 316Lstainlesssteel flange,boltand nut,andmetal wound gasket | |
| S | 9: Special order | |
| Cable | 00 | The cable length increases every 5m,with the default of Oo(3m) and the longest of 95m. |
| Certification □ | 0 | Factoryverificationcertificate |
| 1 | Verification certificate of national verification institution | |
| 2 | Verificationcertificateof third-partydesignated organization | |
| 3 | XXXX |
SelectionTableofMFM-L SeriesMassFlowmeters
| Option description | Code | Code information description |
| Product main name □ | MFML | Diameter: DN3-DN3OO; three digits: the first and second digits of DN and the number of zeros following the first two digits (unit: mm). |
| Sensor model □ | CFS003 | (0~110)kg/h |
| CFS006 | (0~1200)kg/h | |
| CFS015 | (0~3000)kg/h | |
| CFS020 | (0~7200)kg/h | |
| CFS025 | (0~12000)kg/h | |
| CFS040 | (0~32000)kg/h | |
| CFS050 | (0~60000)kg/h | |
| CFS080 | (0~180000)kg/h | |
| CFS100 | (0~300000)kg/h | |
| CFS150 D | (0~600000)kg/h | |
| Sensor characteristics | 316LCryogenic-200cC (body 316L,cover 304) | |
| □ | S | Special order(special material: 304L,Hastelloy C22,duplex stainless steel, tantalum) |
| 1 | Class 0.5 | |
| 2 | Class 0.2 | |
| Process connection | 3 | Class 0.15 |
| 4 | Class 0.1 | |
| 1 | GB/T9115-2010RFweldingneck flange4MPaWN-RF | |
| 2 | GB/T9115-2010RFweldingneck flange1.6MPaWN-RF | |
| 3 | GB/T9115-2010RFweldingneck flange6.3MPaWN-RF | |
| 4 | HG/T20615-2009RFweldingneckflangeClass300WN-RF | |
| 5 | ASMEB16.5-2009RFwelding neck flangeClass150WN-RF | |
| 6 | ASMEB16.5-2009RFweldingneckflangeClass300WN-RF | |
| 7 8 | HG/T20592-2009RFweldingneckflange4MPaWN-RF | |
| HG/T20592-2009RFwelding neck flange1.6MPaWN-RF | ||
| 9 | ASMEB16.5-2009RFweldingneckflangeClass600WN-RF Threaded connection (DN15and DN25only) | |
| A B | Threaded connection (DN15 and DN20 only) High-pressure type | |
| S | Special order | |
| CFT100 | Chinese/Englishswitching interface,IP67,ExdibIIBT1-T6Gb,shunt type | |
| Converter model□ Electrical interface of | M | M20 |
| N | 1/2NPT | |
| converter power supply and signal line□ Power supply mode | S | T: Special order |
| 1 | 18VDC-36VDC | |
| 2 | 85VAC-265VAC |
| Option description | Code | Code information description |
| Communication and data acquisition mode | 1 | Activecirculatingcurrent(4~20)mA+frequency(0~10)kHz+RS485 |
| 2 | Active circulatingcurrent (4~20)mA+frequency(0~10)kHz+HART | |
| 3 | Passive circulating current (4~20)mA+frequency (0~10)kHz+RS485 | |
| 4 | Passive circulatingcurrent (4~20)mA+frequency(0~10)kHz+HART | |
| S | Special order | |
| Measurement mode □ | A | Standard measurement type |
| F | Undefined | |
| Installation method □ | Y | Integrated type (only forDN50 and above) |
| F | Split type | |
| Annex □ | 0 | N/A |
| 1 | Carbonsteel flange,boltand nut,and metal wound gasket | |
| 2 | 304 stainless steel flange,boltand nut,and metal wound gasket | |
| 3 | 316L stainless steel flange,bolt and nut,and metal wound gasket | |
| S | 9: Special order | |
| Cable□ | 00 | The cable length increases every 5m,with the default of OO(3m) and the longest of 95m. |
| Certification □ | 0 | Factoryverificationcertificate |
| 1 | Verificationcertificateofnationalverificationinstitution | |
| 2 | Verification certificate of third-party designated organization | |
| 3 | XXXX |
CHONGQINGCHUANYIAUTOMATIONCO.,LTD.FLOWMETERBRANCH
Address:No.61,Middle Section of Huangshan Avenue,New North Zone,Chongqing,China Tel.:023-67032678 67032666 67032667 67032668 67032669 Fax:023-67032676 Postal code:401121 Website:www.sicflow.com.cn Email:flowmaster@sicc.com.cn flowmaster@sicflow.com.cn
PleasescantheQRcode ofChongqing Chuanyi
QRcodeofChuanyi Flowmeter