FAN COIL UNIT
Contents
01 ENTERPRISE
About yesncer 01
Enterprise qualification 05
Development history 07
Cutomers' Visit 09
Services We Provide 11
02
ABOUT PRODUCT
Horizontal Concealed FCU 13
Horizontal Concealed FCU 190mm 28
Cassette fan coil unit 35
Slim Exposed FCU 47
Ultra-thin Exposed FCU 52
Exposed Fan coil Unit 57
Wall hanging Fan Coil Unit 61
4P Cabinet Fan Coil unit 67
High static pressure fcu 69
AHU catalog (combined) 73
I ABOUT YESNCER
Yuexin Company is an advanced professional heating and cooling equipment manufacturer in China that integrates R&D, production, sales and services. It was rated as a "National High-tech Enterprise" in 2022. After more than 30 years of continuous development, it has successively conquered super-national standard fan coils, combined air-conditioning units, constant temperature and humidity units, functional fan coils, industrial and agricultural heating and cooling fans.
The independently developed variable frequency series fan coils have outstanding use effects and are well received by users. High-performance open-mounted products are sold well in the international market and are now serving more than 60 countries around the world. Yuexin's full-scene application terminal products quickly lead the new market trend with its own unique style. Yuexin creates a learning-oriented corporate organization with the core values of "professionalism, innovation, and excellence".
With the business philosophy of "providing customers with high-quality products and services", it develops world-class central air-conditioning terminal products to meet the growing demand of the global market for comfortable, energy-saving and beautiful products. It is the driving force for Yuexin's development.
Yesncer always adhere to the implementation of "pre-sale, sale, after-sales" three-stage service, adhere to "your every little thing is our big thing" as a service concept. Management standard, unified standards, committed to the best service
Set up remote intelligent service center, professional team real-time monitoring, in this era of consumer power, we recognize that your journey with our products or services does not end after the transaction. This is just the beginning of a lasting relationship that we are committed to nurturing and maintaining.
Our after-sales service is more than just a promise; It's a deal. We promise unparalleled support, assistance and satisfaction. Ensure that your journey is as exciting as the first contact, and provide users with a more effortless, worrying and money-saving central air conditioning service.
Establish user installation and maintenance database to provide users with quality service in time.
39+
TECHNOLOGICAL SEDIMENTATION
Research and development strength
Yesncer is a specialized central air conditioning end production company, has always adhered to independent research and development, adhering to the "no ceiling" in research and development funds to implement the "on-demand investment" principle, only in 2021 scientific research investment reached 5,726,800 yuan.
Yesncer has trained more than 20 professional and technical backbones to form different levels of technical research and development teams. Continue to receive the industry's cutting-edge information, learning, discussion, a strong guarantee of technological research and development of innovation.
The company has refrigeration technology research laboratory, mechanical and electrical technical engineer, professional HVAC design team, professional HVAC master, ISO9001 quality management system certification, ISO14001 environmental management system certification, and won the EU CE certification in 2021.
EXPORT COUNTRIES
Warehousing strength
Yesncer is located in the ancient city of Baoding, Hebei Province, in the heart of the logistics center, and is very close to Beijing and Tianjin Port, covers an area of 5000 square meters, the daily reserve of 20,000 units, warehousing using ERP management system to ensure accuracy.
Existing cooperative logistics of SF Express, Deppon, Aneng, One meter Tick and other cooperative logistics, order direct destination! To serve customers accurately, efficiently and quickly
Quality control
Control system basis: The core is based on national GB/T19232-2019, and the safety performance has passed the IS09001 quality management system certification, IS014001 environmental management system certification, and IS045001 Occupational health and safety management system certification by Hefei General Machinery Research Institute. Key parameters of the production process.
Production technology
Advanced simulation, design tools SOLIDWORKS design modeling software, independent AHU selection software, independent research and development of linear design software. High-precision machining equipment Automatic welding equipment, air-tight helium leak detection technology, dynamic balance testing machine and other precision CNC machining equipment.
Scientific and rigorous quality control system Supply system → key parameter production process control system →QC system → Packaging system →storage system → pre-shipment inspection system → after-sales service system
3000 +
100 %
NATIONAL SERVICE NETWORK
FULL SHIPMENT INSPECTION
I ENTERPRISE QUALIFICATIONS
I DEVELEPMENT HISTORY
I Cutomers' Visit
SERVICE WE SUPPLY
CUSTOMIZED
The CAD design drawing plan of the project are available
GOODS TRACKING
We will following the goods delivery untill you got the goods
INSTALLATION GUIDE
Supply the installation and maintanence instruction online
The free spare parts available
QUALITY GUARANTEED
If any quality problem of product, we can refund you
You can get us at any time, after order placed
WARRANTY
Three years' warranty
Details parts of the fan coil unit
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 | |
| Cooling Ca.(Water in 7°C) | kw | 1.9 | 2.8 | 3.75 | 4.6 | 5.5 | 7.3 | 9.2 | 11 | 12.8 |
| Heating Ca.(Water in 60°C) | kw | 3.4 | 5.18 | 6.67 | 7.5 | 9.35 | 12.4 | 14.7 | 17.6 | 20.5 |
| Power Input | w | 36 | 50 | 60 | 74 | 93 | 130 | 147 | 183 | 221 |
| Air flow | m³/h | 357 | 535 | 714 | 892 | 1071 | 1428 | 1785 | 2090 | 2390 |
| Motor Power | w | 25 | 20 | 25 | 25 | 40 | 40+25 | 40+40 | 40+40 | 50+50 |
| Noise | dB(A) | 37 | 39 | 41 | 43 | 45 | 47 | 48 | 50 | 52 |
| Motor No. | 1 | 2 | ||||||||
| Fan No. | 1 | 2 | 3 | 4 | ||||||
| Static pressure | 30Pa | |||||||||
| Water flow | m³/h | 0.32 | 0.478 | 0.64 | 0.797 | 0.956 | 1.275 | 1.59 | 1.9 | 2.23 |
| Condenser length | mm | 450 | 580 | 650 | 760 | 900 | 1100 | 1350 | 1550 | 1750 |
| Condenser height | mm | 20065 | ||||||||
| Condenser Width | mm | |||||||||
| Iron Wheel Weight | kg | 10.7 | 13.2 | 14.2 | 15.4 | 17 | 22.7 | 27 | 28.8 | 31.2 |
| ABS Weight | kg | 10.3 | 12.6 | 13.4 | 14.6 | 16.2 | 21.9 | 26.2 | 28 | 30.4 |
| Package length | mm | 790 | 880 | 980 | 1080 | 1180 | 1380 | 1680 | 1880 | 2080 |
| Package width | mm | 520250 | ||||||||
| Package height | mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A | 755 | 855 | 955 | 1055 | 1155 | 1355 | 1655 | 1855 | 2055 |
| B | 505 | 635 | 705 | 815 | 955 | 1155 | 1405 | 1605 | 1805 |
| C | 477 | 607 | 677 | 787 | 927 | 1127 | 1377 | 1577 | 1777 |
| Model | FCU-02EC F | CU-03EC | FCU-04EC | FCU-05ECF | CU-06EC | FCU-08EC | FCU-10EC | FCU-12EC | FCU-14EC | |
| Cooling Ca.(Water in 7°℃) | kw | 1.8 | 3.26 | 3.97 | 4.6 | 5.75 | 7.45 | 9.19 | 10.8 | 12.7 |
| Heating Ca.(Water in 60°C) | kw | 3.49 | 5.27 | 6.77 | 8.65 | 11.17 | 13 | 15.97 | 17.7 | 21.2 |
| Power Input (12Pa) | w | 14 | 16.7 | 22.4 | 32.9 | 52.1 | 60 | 72.8 | 92.7 | 125.2 |
| Power Input (30Pa) | w | 19.8 | 24.3 | 32.5 | 43.5 | 67 | 78.5 | 92.2 | 116 | 156 |
| Power Input (50Pa) | w | 26.3 | 32.4 | 42.5 | 55.7 | 82.2 | 98 | 115.9 | 155.5 | 186 |
| Noise (12Pa) | dB(A) | 18~32 | 18~30 | 20~34 | 23~38 | 29~43 | 28~42 | 32~43 | 33~44 | 37~47 |
| Noise (30Pa) | dB(A) | 20~38 | 20~37 | 22~41 | 24~43 | 30~47 | 31~46 | 34~47 | 34~48 | 38~49 |
| Noise (50Pa) | dB(A) | 23~43 | 22~42 | 25~45 | 26~47 | 33~50 | 34~49 | 36~51 | 37~51 | 39~53 |
| Air Flow | m3/h | 360 | 545 | 724 | 900 | 1090 | 1440 | 1750 | 2140 | 2490 |
| Motor Power | w | 60 | ||||||||
| Motor No. | 1 | 2 | ||||||||
| Fan No. | 1 | 2 | 3 | 4 | ||||||
| Static pressure | 0~50Pa | |||||||||
| Water flow | m³/h | 0.4 | 0.59 | 0.73 | 0.81 | 1 | 1.2 | 1.57 | 1.86 | 2.19 |
| Condenser length | mm | 450 | 580 | 650 | 760 | 900 | 1100 | 1350 | 1550 | 1750 |
| Condenser height | mm | 210 | ||||||||
| Condenser Width | mm | 38.1 | ||||||||
| Weight | kg | 10.1 | 12.1 | 13 | 14.2 | 15.5 | 20.1 | 23.5 | 25.5 | 27.3 |
| Package length | mm | 790 | 880 | 980 | 1080 | 1180 | 1380 | 1680 | 1880 | 2080 |
| Package width | mm | 520250 | ||||||||
| Package height | mm | |||||||||
| Unit: mm | |||||||||
| Model | FCU-02EC | FCU-03EC | FCU-04EC | FCU-05EC | FCU-06EC | FCU-08EC | FCU-10EC | FCU-12EC | FCU-14EC |
| A | 755 | 855 | 955 | 1055 | 1155 | 1355 | 1655 | 1855 | 2055 |
| B | 505 | 635 | 705 | 815 | 955 | 1155 | 1405 | 1605 | 1805 |
| C | 477 | 607 | 677 | 787 | 927 | 1127 | 1377 | 1577 | 1777 |
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 | |
| 3+1Cooling Ca.(Water in 7℃ ) | kw | 1.85 | 2.78 | 3.7 | 4.63 | 5.56 | 7.41 | 9.27 | 11.1 | 12.9 |
| 3+1Heating Ca.(Water in 60℃ ) | kw | 1.2 | 1.9 | 2.5 | 3.1 | 3.7 | 4.85 | 6.1 | 7.3 | 8.6 |
| 2+2Cooling Ca.(Water in 7℃ ) | kw | 1.2 | 1.8 | 2.5 | 3.2 | 3.8 | 5.1 | 6.2 | 7.7 | 8.8 |
| 2+2Heating Ca.(Water in 60℃ ) | kw | 1.8 | 2.8 | 3.8 | 4.7 | 5.7 | 7.7 | 9.5 | 11.3 | 13.2 |
| Power Input | w | 36 | 50 | 60 | 74 | 93 | 130 | 147 | 183 | 221 |
| Air Flow | m³/h | 357 | 535 | 714 | 892 | 1071 | 1428 | 1785 | 2090 | 2390 |
| Motor Power | w | 25 | 20 | 25 | 25 | 40 | 40+25 | 40+40 | 40+40 | 50+50 |
| Noise | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 |
| Motor No. | 1 | 2 | ||||||||
| Fan No. | 1 | 2 | 3 | 4 | ||||||
| Static pressure | 30Pa | |||||||||
| Water flow | m³/h | 0.32 | 0.478 | 0.64 | 0.797 | 0.956 | 1.275 | 1.594 | 1.913 | 2.232 |
| Condenser length | mm | 450 | 580 | 650 | 760 | 900 | 1100 | 1350 | 1550 | 1750 |
| Condenser height | mm | 200108.3 | ||||||||
| Condenser Width | mm | |||||||||
| Iron Wheel Weight | kg | 10.7 | 13.2 | 14.2 | 15.4 | 17 | 22.7 | 27 | 28.8 | 31.2 |
| ABS Weight | kg | 10.3 | 12.6 | 13.4 | 14.6 | 16.2 | 21.9 | 26.2 | 28 | 30.4 |
| Package length | mm | 790 | 880 | 980 | 1080 | 1180 | 1380 | 1680 | 1880 | 2080 |
| Package width | mm | 520260 | ||||||||
| Package height | mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A | 755 | 855 | 955 | 1055 | 1155 | 1355 | 1655 | 1855 | 2055 |
| B | 505 | 635 | 705 | 815 | 955 | 1155 | 1405 | 1605 | 1805 |
| C | 477 | 607 | 677 | 787 | 927 | 1127 | 1377 | 1577 | 1777 |
| Unit: mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A (Total length) | 755 | 855 | 955 | 1055 | 1155 | 1355 | 1655 | 1855 | 2055 |
| B (Plenum length) | 507 | 637 | 707 | 817 | 957 | 1157 | 1407 | 1607 | 1807 |
| C (Distance betweenlifting holes) | 477 | 607 | 677 | 787 | 927 | 1127 | 1377 | 1577 | 1777 |
| The maximumnumber of air outlets(150mm) | 2 | 3 | 3 | 4 | 5 | 6 | 7 | 8 | 9 |
| The maximumnumber of air outlets(200mm) | 1 | 2 | 2 | 3 | 3 | 4 | 5 | 6 | 7 |
Static pressure box material: 0.8mm hot-dip galvanized sheet metal, no flower and no oil, static pressure port is made of ABS material
| Unit: mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A(Total length) | 755 | 855 | 955 | 1055 | 1155 | 1355 | 1655 | 1855 | 2055 |
| B(Plenum length) | 507 | 637 | 707 | 817 | 957 | 1157 | 1407 | 1607 | 1807 |
| C(Distance betweenlifting holes) | 477 | 607 | 677 | 787 | 927 | 1127 | 1377 | 1577 | 1777 |
| The maximumnumber of jet ports | 3 | 4 | 5 | 6 | 7 | 9 | 10 | 12 | 14 |
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A (Total length) | 755 | 855 | 955 | 1055 | 1155 | 1355 | 1655 | 1855 | 2055 |
| B (Plenum length) | 507 | 637 | 707 | 817 | 957 | 1157 | 1457 | 1607 | 1807 |
| C (Distance betweenlifting holes) | 477 | 607 | 677 | 787 | 927 | 1127 | 1377 | 1577 | 1777 |
| The max NO ofdamper | 1 | 2 | 2 | 3 | 3 | 3 | 4 | 5 | 5 |
Brief :
Product name: Ultra-thin concealed fan coil unit with electric damper developed by ourselves.
The different damper could connect the air duct to different rooms to solve the problem of not enough space for install enough fan coil units.
What's more, the using room only a air inlet, no moise of the fan coil unit.
There the PCB we developed by ourselves, relizng seperate control in different rooms.
Control logic : One room open the thermostat, the fan coil open, all the thermsotat close, the fan coil unit close.
When the room temprature reach to the setting tempearature, the damper will be closed.
If you think the air flow is not enough, the RPM of the motor could be set by yourself on the PCB.
| Unit: mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A (Total Length) | 755 | 855 | 955 | 1055 | 1155 | 1355 | 1655 | 1855 | 2055 |
| B(Distance betweenlifting holes) | 477 | 607 | 677 | 787 | 927 | 1127 | 1377 | 1577 | 1777 |
| C(Elbow length(tuyere length)) | 512 | 642 | 712 | 822 | 962 | 1162 | 1412 | 1612 | 1812 |
| Unit: mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A | 755 | 855 | 955 | 1055 | 1155 | 1355 | 1655 | 1855 | 2055 |
| B | 505 | 635 | 705 | 815 | 955 | 1155 | 1405 | 1605 | 1805 |
| C | 477 | 607 | 677 | 787 | 927 | 1127 | 1377 | 1577 | 1777 |
| D | 510 | 640 | 710 | 820 | 960 | 1160 | 1410 | 1610 | 1810 |
| E | 460 | 590 | 660 | 770 | 910 | 1110 | 1360 | 1560 | 1760 |
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 | |
| Cooling Ca.(Water in 7°℃) | kw | 1.8 | 2.7 | 3.6 | 4.5 | 5.4 | 7.2 | 9.0 | 10.8 | 12.6 |
| Heating Ca.(Water in 60℃) | kw | 2.7 | 4.05 | 5.4 | 6.75 | 8.1 | 10.8 | 13.5 | 16.2 | 18.9 |
| Power | w | 36 | 50 | 60 | 74 | 93 | 130 | 147 | 183 | 220 |
| Air flow | m3/h | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
| Noise | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 |
| Static pressure | 12Pa | |||||||||
| Water flow | m³/h | 0.32 | 0.478 | 0.64 | 0.797 | 0.956 | 1.275 | 1.594 | 1.913 | 2.232 |
| Condenser length | mm | 460 | 580 | 650 | 730 | 850 | 1050 | 1310 | 1510 | 1600 |
| Condenser height | mm | 190 | ||||||||
| Condenser Width | mm | 40 | ||||||||
| Iron Wheel Weight | kg | 11 | 14 | 15 | 17 | 18 | 25 | 28 | 34 | 38 |
| ABS Weight | kg | 10 | 13 | 14 | 16 | 17 | 24 | 27 | 33 | 37 |
| Unit:"mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A | 600 | 760 | 830 | 910 | 1030 | 1290 | 1500 | 1690 | 1790 |
| B | 410 | 570 | 640 | 730 | 850 | 1100 | 1310 | 1510 | 1600 |
| C | 460 | 610 | 690 | 780 | 870 | 1170 | 1360 | 1560 | 1650 |
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 | |
| 2+2 Cooling Ca.(Water in 7°C) | kw | 1.8 | 2.7 | 3.6 | 4.5 | 5.4 | 7.2 | 9.0 | 10.8 | 12.6 |
| 2+2 Heating Ca.(Water in 60°℃ ) | kw | 1.2 | 1.8 | 2.4 | 3.1 | 3.6 | 4.8 | 6.1 | 7.3 | 8.5 |
| 2+2 Cooling Ca.(Water in 7°C) | kw | 1.2 | 1.8 | 2.5 | 3.2 | 3.8 | 5.1 | 6.2 | 7.7 | 8.8 |
| 2+2 Heating Ca.(Water in 60°℃ ) | kw | 1.8 | 2.8 | 3.8 | 4.7 | 5.7 | 7.7 | 9.5 | 11.3 | 13.2 |
| Power Input | w | 36 | 50 | 60 | 74 | 93 | 130 | 147 | 183 | 220 |
| Air flow | m³/h | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
| Noise | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 |
| Static pressure | 12Pa | |||||||||
| Condenser length | mm | 460 | 580 | 650 | 730 | 850 | 1050 | 1310 | 1510 | 1600 |
| Condenser height | mm | 190 | ||||||||
| Condenser Width | mm | 52 | ||||||||
| Iron Wheel Weight | kg | 12 | 15 | 16 | 19 | 20 | 27 | 31 | 36 | 41 |
| ABS Weight | kg | 11 | 14 | 15 | 18 | 19 | 26 | 30 | 35 | 40 |
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A | 600 | 760 | 830 | 910 | 1030 | 1290 | 1500 | 1690 | 1790 |
| B | 410 | 570 | 640 | 730 | 850 | 1100 | 1310 | 1510 | 1600 |
| C | 460 | 610 | 690 | 780 | 870 | 1170 | 1360 | 1560 | 1650 |
Ultra-thin Fan Coil Unit Data Sheet
| Product Name | Ultra-thin concealed fan coil unit(AC motor) | ||
| Application | It is widely used for hotel,restaurant,hospital,shopping mall,factory and office building etc.And some other villa | ||
| Product Function | It can be used for cooling, heating, dehumidification | ||
| Product Models | FP-51/68/85/102/136/170CB | ||
| CoilCooper | Fin | 0.105mm thickness aluminum fins, distance between fins is 1.3mm | |
| tube | ameter, 30 tubes or 24tubes in total | ||
| Drain pan | aterial with plastic coating | ||
| Drain | Drain pump | Optional (internal) | |
| Alertor | Optional | ||
| ProductComponents | Shell | Panel | 1mm Al-Zn-Si hot-dip galvanized steel sheet |
| Insulation | EVA insulation pasted outside and inside the panel, B1 rating. | ||
| Motor | EC motor with3-speed or 0-10v thermostat | ||
| Label | Labels: model label, wiring diagram, precautions, fan rotation, logo, etc. | ||
| Fan | ABS material Centrifugal, forward-curved blades | ||
| Control | Could connect both 3-speed thermostat and 0-10V thermostat. | ||
| ProductionTechnology | Tube | Mechanical expansion, automatic welding | |
| Body Panel | Fully automatic molding in one molding, with longitudinal reinforcement at the bend | ||
| Motor panel | Hydraulic abrasive ribs+longitudinal reinforcement at the bend | ||
| Inspection Standards | 1. No scratches or rust on the surface of the machine2. The internal cooler of the machine has no leakage under the pressure of 1.6Mpa(hold pressure for at least 5min)3. The unit starts under the condition of 90% of the rated voltage and runs stably for 10 minutes4. Under normal temperature and humidity conditions, use 500V insulation resistance meter tomeasure the insulation resistance between the live part and non-metal live part of the unit isnot less than 2MΩ | ||
| Model | A Total length | B Body length | C air outlet length | D lifting eye distance | F & G Air intake length | |
| FP-51CB | CBFCU-03EC | 926 | 848 | 650 | 890 | 740 |
| FP-68CB | CBFCU-04EC | 926 | 848 | 650 | 890 | 740 |
| FP-85CB | CBFCU-05EC | 1176 | 1098 | 900 | 1140 | 990 |
| FP-102CB | CBFCU-06EC | 1176 | 1098 | 900 | 1140 | 990 |
| FP-136CB | CBFCU-08EC | 1626 | 1548 | 1350 | 1590 | 1440 |
| FP-170CB | CBFCU-10EC | 1626 | 1548 | 1350 | 1590 | 1440 |
Parameter of both Ultra-thin FCU
| Model | FP-51CB | FP-68CB | FP-85CB | FP-102CB | FP-136CB | FP-170CB | ||
| Motor power | w | 12 | 20 | 20 | 25 | 25+25 | 40+40 | |
| Power consumption | w | 48 | 55 | 72 | 90 | 129 | 148 | |
| Motor NO. | 1 | 2 | ||||||
| Fan NO. | 2 | 4 | ||||||
| Static Pressure | Pa | 12Pa | ||||||
| Air flow | m³/h | 530 | 700 | 875 | 1030 | 1360 | 1750 | |
| Cooling capacity(7°C chilled water) | kw | 2.8 | 3.7 | 4.7 | 5.7 | 7.8 | 9.4 | |
| Heating capacity(60°C hot water) | dB(A) | 5.0 | 6.5 | 7.2 | 9.1 | 11.8 | 14.8 | |
| H | dB(A) | 39 | 41 | 43 | 45 | 46 | 48 | |
| Noise | M | dB(A) | 36 | 38 | 41 | 42 | 43 | 45 |
| L | kg | 33 | 35 | 36 | 38 | 39 | 40 | |
| Weight | Net weight | kg | 18.3 | 18.5 | 21.2 | 21.5 | 30.6 | 31 |
| Gross weight | mm | 21 | 21.3 | 24.4 | 24.7 | 34.6 | 35 | |
| Coil length | mm | 650 | 650 | 900 | 900 | 1330 | 1330 | |
| Coil width | mm | 210 | ||||||
| Coil thickness | mm | 38.1 | ||||||
| L | mm | 1040 | 1040 | 1290 | 1290 | 1740 | 1740 | |
| Packagesize | H | mm | 565250 | |||||
| W | ||||||||
More Parameter of ultra-thin concealed FCU (EC motor)
| Model | S.P. | 12Pa | 30Pa | 50Pa | |||
| CBFCU-03EC | Votage adjust | 3.1V | 5.5V | 3.4V | 6.5V | 3.8V | 7.5V |
| Air Flow(m³/h) | 260 | 516 | 270 | 520 | 270 | 510 | |
| Noise(dBA) | 18 | 34 | 20 | 39 | 27 | 41 | |
| CBFCU-04EC | Votage adjust | 3.4V | 6.5V | 3.6V | 7.5V | 3.9V | 8.5V |
| Air Flow(m³/h) | 320 | 697 | 330 | 688 | 340 | 684 | |
| Noise(dBA) | 21 | 40 | 23 | 41 | 29 | 44 | |
| CBFCU-05EC | Votage adjust | 3.6V | 6.4V | 3.8V | 7.5V | 4.1V | 8.7V |
| Air Flow(m³/h) | 400 | 860 | 350 | 877 | 360 | 876 | |
| Noise(dBA) | 22 | 41 | 26 | 43 | 28 | 46 | |
| CBFCU-06EC | Votage adjust | 3.8V | 7.5V | 4.2V | 8.5V | 5V | 9.8V |
| Air Flow(m³/h) | 450 | 1100 | 460 | 1030 | 480 | 1040 | |
| Noise(dBA) | 24 | 43 | 27 | 45 | 29 | 48 | |
| CBFCU-08EC | Votage adjust | 4V | 6.8V | 4.3V | 7.8V | 5V | 8.5V |
| Air Flow(m³/h) | 700 | 1480 | 640 | 1380 | 730 | 1400 | |
| Noise(dBA) | 26 | 43 | 32 | 47 | 38 | 49 | |
| CBFCU-10EC | Votage adjust | 4.2V | 8.2V | 4.8V | 9.0V | 5V | 9.5V |
| Air Flow(m³/h) | 750 | 1720 | 840 | 1750 | 850 | 1730 | |
| Noise(dBA) | 28.2 | 45 | 34 | 48 | 38 | 51 | |
Ultra-thin concealed fan coil unit (0-10v EC motor)
| CBFCU-05EC CBFCU-06EC | CBFCU-08EC | |||||||
| Model | CBFCU-03EC | CBFCU-04EC | ||||||
| Motor power | w | |||||||
| 60 | ||||||||
| Power consumption | w | 33 | 45 | 52 | 83 | 63 | 116 | |
| Motor NO. | 1 | 2 | ||||||
| Fan NO. | 2 | 4 | ||||||
| Cooling capacity(7°C chilled water) | kw | 2850 | 3730 | 4700 | 5724 | 7810 | 9486 | |
| Heating capacity(60°C hot water) | kw | 5000 | 6520 | 7220 | 9108 | 11870 | 14810 | |
| Weight | Net weight | kg | 18.3 | 18.5 | 21.2 | 21.5 | 30.6 | 31 |
| Gross weight | kg | 21 | 21.3 | 24.4 | 24.7 | 34.6 | 35 | |
| Coil length | mm | 650 | 650 | 900 | 900 | 1350 | 1350 | |
| Coil width | mm | 21 | 0 | |||||
| Coil | thickness | mm | 39 | |||||
| long | mm | 1040 | 1040 | 1290 | 1290 | 1740 | 1740 | |
| Packagesize | wide | mm | 565250 | |||||
| thick | mm | |||||||
| Model | S.P. | 12Pa | 30Pa | 50Pa | |||||||||
| CBFCU-03EC | DIP Switch adjust | 1100 | 1110 | 1101 | |||||||||
| Air Flow(m3/h) | 350 | 580 | 380 | 545 | 390 | 550 | |||||||
| Noise(dBA) | 23 | 35.8 | 25 | 40 | 30 | 42.5 | |||||||
| CBFCU-04EC | DIP Switch adjust | 111 | 0 | 110 | 1 | 011 | 1 | ||||||
| Air Flow(m3/h) | 400 | 695 | 420 | 710 | 340 | 685 | |||||||
| Noise(dBA) | 24 | 41 | 25 | 42 | 30 | 44.5 | |||||||
| CBFCU-05EC | DIP Switch adjust | 111 | 0 | 110 | 1 | 011 | 1 | ||||||
| Air Flow(m3/h) | 450 | 865 | 400 | 850 | 390 | 870 | |||||||
| Noise(dBA) | 24 | 42 | 25 | 43 | 28.8 | 46.5 | |||||||
| CBFCU-06EC | DIP Switch adjustAir Flow(m3/h) | 1101 | 101 | 1 | 011 | 1 | |||||||
| 510 | 1080 | 490 | 1025 | 470 | 1040 | ||||||||
| Noise(dBA) | 25 | 42.5 | 27.5 | 44.8 | 28 | 48 | |||||||
| CBFCU-08EC | DIP Switch adjust | 000 | 1 | 101 | 1 | 011 | 1 | ||||||
| Air Flow(m3/h) | 750 | 1430 | 650 | 1490 | 650 | 1400 | |||||||
| Noise(dBA) | 27 | 43.3 | 32.5 | 46 | 34 | 47 | |||||||
| CBFCU-10EC | DIP Switch adjust | 0011 | 1011 | 011 | 1 | ||||||||
| Air Flow(m3/h) | 810 | 1720 | 790 | 1750 | 780 | 1730 | |||||||
| Noise(dBA) | 30 | 46 | 30 | 48 | 32 | 51 | |||||||
| Digital Code | 000 | 0 | 0010 | 0110 | |||||||||
| Dip sample | Tm | mm | |||||||||||
\* Data sheet of air flow and noise in different DIP switch setting connected 3-speed thermostat
Slim Horizontal Concealed Fan Coil Unit With Electrical Damper
One fan coil used for a few of rooms
Product name: Ultra-thin concealed fan coil unit with electric damper developed by ourselves.
The different damper could connect the air duct to different rooms to solve the problem of not enough space for Install enough fan coil units.
What's more, the using room only a air inlet, no moise of the fan coil unit.
There the PCB we developed by ourselves, relizng seperate control in different rooms.
Control logic : One room open the thermostat, the fan coil open, all the thermsotat close, the fan coil unit close.
When the room temprature reach to the setting tempearature, the damper will be closed.
if you think the air flow is not enough, the RPM of the motor could be set by yourself on the PCB.
Drawing of ultra-thin concealed FCU (EC motor) with damper
| Model | CBFCU-03EC | CBFCU-04EC | CBFCU-05EC | CBFCU-06EC | CBFCU-08EC | CBFCU-10EC |
| A | 859 | 859 | 1109 | 1109 | 1579 | 1579 |
| B | 265 | 265 | 312.5 | 312.5 | 400 | 400 |
| C | 263.5 | 163.5 | 241 | 241 | 188 | 188 |
| D | 890 | 890 | 1140 | 1140 | 1609 | 1609 |
| E | 759 | 759 | 1009 | 1009 | 1478 | 1478 |
| Damper Dia | 150 | 150 | 150 | 150 | 150 | 150 |
Structure of 4-way cassette
| Model | FP-34KM-SF | P-51KM-SF | P-68KM-SF | P-85KM-SF | P-102KM-S F | P-136KM-SF | P-170KM-SF | P-204KM-SF | P-238KM-S | |
| Cooling Ca. (kw)(Water in 7°C)(Air inlet temperature:DB 27℃, WB19.5℃) | H | 1.98 | 2.98 | 3.68 | 4.98 | 5.4 | 7.2 | 9.9 | 10.8 | 12.6 |
| M | 1.63 | 2.27 | 2.81 | 3.75 | 4.32 | 5.53 | 7.51 | 8.08 | 9.68 | |
| L | 1.04 | 1.51 | 1.89 | 2.51 | 2.85 | 5.53 | 5.00 | 5.55 | 6.45 | |
| Heating Ca. (kw)(Water in 60°C)(Air inlet temperature:DB 20C) | H | 2.97 | 4.80 | 5.48 | 7.20 | 8.1 | 10.80 | 14.50 | 16.20 | 18.90 |
| M | 2.45 | 3.67 | 4.19 | 5.42 | 6.33 | 8.17 | 11.00 | 12.35 | 14.52 | |
| L | 1.57 | 2.44 | 2.82 | 3.60 | 4.52 | 5.47 | 7.33 | 8.48 | 9.68 | |
| Air flow (m³/h) | H | 345 | 510 | 690 | 875 | 1035 | 1375 | 1705) | 2045 | 2380 |
| M | 280 | 390 | 520 | 640 | 790 | 1030 | 1290 | 1500 | 1800 | |
| L | 180 | 260 | 350 | 430 | 520 | 690 | 860 | 1030 | 1200 | |
| Power Input (W) | 50 | 50 | 58 | 72 | 92 | 126 | 128 | 152 | 198 | |
| Current (A) | 0.151 | 0.225 | 0.258 | 0.32 | 0.385 | 0.561 | 0.547 | 0.677 | 0.882 | |
| Noise (dB (A)) | 37 | 39 | 41 | 43 | 45 | 46 | 47 | 49 | 52 | |
| Static Pressure (Pa) | 12 | |||||||||
| Power Supply | 220-240v/1ph/50HzWired or remote controller | |||||||||
| Control Way | ||||||||||
| Water Flow (m³/h) | 0.42 | 0.52 | 0.62 | 0.86 | 0.98 | 1.0825 | 1.58 | 1.7844 | 1.9246 | |
| Water Pressure Drop(kPa) | 14 | 14 | 16 | 18 | 22 | 39 | ||||
| Water Pipe For in/out | ZG3/4 | |||||||||
Size Drawing of Self-drainage 4 way Cassette:
| Model | FP-34KM | FP-51KM | FP-68KM | FP-85KM | FP-102KM | FP-136KM | FP-170KM | FP-204KM | FP-238KM | |
| Cooling Ca. (kw)(Water in 7°C)(Air inlet temperature:DB 27℃, WB19.5℃) | H | 1.98 | 2.98 | 3.68 | 4.98 | 5.4 | 7.2 | 9.9 | 10.8 | 12.6 |
| M | 1.63 | 2.27 | 2.81 | 3.75 | 4.32 | 5.53 | 7.51 | 8.08 | 9.68 | |
| L | 1.04 | 1.51 | 1.89 | 2.51 | 2.85 | 5.53 | 5.00 | 5.55 | 6.45 | |
| Heating Ca. (kw)(Water in 60°C) | H | 2.97 | 4.80 | 5.48 | 7.20 | 8.1 | 10.80 | 14.50 | 16.20 | 18.90 |
| DB 20C) | M | 2.45 | 3.67 | 4.19 | 5.42 | 6.33 | 8.17 | 11.00 | 12.35 | 14.52 |
| L | 1.57 | 2.44 | 2.82 | 3.60 | 4.52 | 5.47 | 7.33 | 8.48 | 9.68 | |
| Air flow (m3/h) | H | 345 | 510 | 690 | 875 | 1035 | 1375 | 1705) | 2045 | 2380 |
| M | 280 | 390 | 520 | 640 | 790 | 1030 | 1290 | 1500 | 1800 | |
| L | 180 | 260 | 350 | 430 | 520 | 690 | 860 | 1030 | 1200 | |
| Power Input (W) | 50 | 50 | 58 | 72 | 92 | 126 | 128 | 152 | 198 | |
| Current (A) | 0.151 | 0.225 | 0.258 | 0.32 | 0.385 | 0.561 | 0.547 | 0.677 | 0.882 | |
| Noise (dB (A)) | 37 | 39 | 41 | 43 | 45 | 46 | 47 | 49 | 52 | |
| Static Pressure (Pa) | 12 | |||||||||
| Power Supply | 220-240v/1ph/50Hz | |||||||||
| Control Way | Wired or remote controller | |||||||||
| Water Flow (m³/h) | 0.42 | 0.52 | 0.62 | 0.86 | 0.98 | 1.08 | 1.58 | 1.78 | 1.92 | |
| Water Pressure Drop(kPa) | 14 | 14 | 16 | 18 | 22 | 25 | 39 | 44 | 46 | |
| Water Pipe For in/out | ZG3/4” | |||||||||
b: Indoor mainframe size
C: Distance from hook to top of indoor unit
d: Distance from top of indoor unit to bottom of ceiling
Size drawing of 2-pipe 4 way Cassette :
290 High End Model Mounting Dimensions
A: Panel size
B: Ceiling Opening Dimensions
C: Indoor unit mainframe size
D: lifting eye Size
4-pipe 4 way Cassette
| Model | FP-34KM-4P | FP-51KM- 4P | FP-68KM-4P | FP-85KM-4P | FP-102KM-4P | FP-136KM-4P | FP-170KM- 4P | FP-204KM-4P | FP-238KM-4P | |
| Cooling Ca. (kw)(Water in 7°C) | H | 1.215 | 1.935 | 2.52 | 3.105 | 3.735 | 4.635 | 6.3 | 7.29 | 8.01 |
| Heating Ca. (kw)(Water in 60°C) | H | 1.53 | 2.295 | 2.88 | 3.69 | 4.365 | 5.31 | 7.38 | 8.325 | 9.045 |
| Air flow (m3/h) | H | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
| Power Input (W) | 34 | 50 | 58 | 72 | 92 | 126 | 128 | 152 | 198 | |
| Running current (A) | 0.151 | 0.225 | 0.258 | 0.32 | 0.385 | 0.561 | 0.547 | 0.547 | 0.882 | |
| Noise dB (A) | 37 | 39 | 41 | 43 | 45 | 46 | 47 | 49 | 52 | |
| Static pressure (Pa) | 12220-240v/1ph/50HzWired or remote controller | |||||||||
| Power Supply | ||||||||||
| Control way | ||||||||||
| Water pipe for in/out | ZG3/4 | |||||||||
| Drain pipe | Male thread 26mm | |||||||||
| Weight (kg) | 21 | 22 | 23 | 30.5 | 31 | 31.5 | 38.5 | 39.5 | 40.5 | |
| Panel size (mm) | 650*650*30 | 800*800*30 | 950*950*30 | |||||||
a: Hook to ceiling base distance b: Indoor mainframe size C: Distance from hook to top of indoor unit d: Distance from top of indoor unit to bottom of ceiling A: Panel size B: Ceiling Opening Dimensions C: Indoor unit mainframe size D: lifting eye Size
Size drawing of 4 pipe :
8 way Cassette Fan Coil Unit
The machine adopts an eight-sided air outlet design, which reduces the indoor air supply resistance, quickly delivers the airflow to every corner, makes the space environment temperature more uniform, and achieves low noise in overall operation.
| Model | FP-170KM-8W | FP-204KM-8W | FP-238KM-8W | |
| Cooling Ca. (kw)(Water in 7°C) | H | 9.9 | 10.4 | 12.6 |
| Heating Ca. (kw)(Water in 60°C) | 工 | 14.5 | 15.2 | 18.9 |
| Air flow (m³/h) | 工 | 1700 | 2040 | 2380 |
| M | 1275 | 1575 | 1850 | |
| L | 850 | 1050 | 1250 | |
| Power Input (W) | 128 | 152 | 198 | |
| Running current (A) | 0.547 | 0.547 | 0.882 | |
| Noise dB (A) | 48 | 49 | 52 | |
| Static pressure (Pa) | 12 | |||
| Power Supply | 220-240v/1ph/50Hz | |||
| Control way | Wired or remote controller | |||
| Water pipe for in/out | ZG3/4" Femal thread | |||
| Drain pipe | Male thread 20mm | |||
| Packing Size(mm) | 1000*1000*380 | |||
| Install whole open size(mm) | 840-900 | |||
| Hanging anchor size(mm) | 867*420 | |||
Size drawing :
Mounting Dimensions
a: Hook to ceiling base distance
b: Indoor mainframe size
C: Distance from hook to top of indoor unit
d: Distance from top of indoor unit to bottom of ceiling
A: Panel size
B: Ceiling Opening Dimensions
C: Indoor unit mainframe size
D: lifting eye Size
2 way Cassette Fan Coil Unit
Removable filter screen, easy toclean and minnannence
| Model | FP-51KM-2W | FP-68KM-2W | FP-85KM-8W | FP-102KM-2W | FP-136KM-8W | |
| Cooling Ca. (kw)(Water in 7°C) | H | 2.7 | 3.8 | 4.5 | 5.4 | 7.2 |
| Heating Ca. (kw)(Water in 60°C) | H | 4.5 | 5.5 | 6.7 | 8 | 10.8 |
| Air flow (m3/h) | H/M/L | 510/390/260 | 680/520/400 | 850/640/490 | 1020/765/600 | 1360/1050/800 |
| Power Input (W) | 50 | 64 | 70 | 85 | 110 | |
| Running current (A) | 0.23 | 0.29 | 0.31 | 0.38 | 0.49 | |
| Noise dB (A) | 39 | 42 | 43 | 45 | 46 | |
| Static pressure (Pa) | 12Pa | |||||
| Power Supply | 220V-50Hz-1Ph | |||||
| Control way | Remote controller (Wired as optional) | |||||
| Water flow(L/H) | 520 | 620 | 776 | 930 | 1245 | |
| Water pressure drop (KPa) | 10 | 11 | 13 | 16 | 20 | |
| Water pipe for in/out | DN20 | |||||
| Unit Size mm | 1259*680*340 | |||||
| Panel Size(mm) | 1240*680*30 | |||||
| Install whole open size(mm) | 1172*475mm | |||||
Size drawing :
Mounting Dimensions
a:: Hook to ceiling base distance
b: Indoor mainframe size
C: Distance from hook to top of indoor unit
d: Distance from top of indoor unit to bottom of ceiling
A: Panel size
B: Ceiling Opening Dimensions
C: Indoor unit mainframe size
D: lifting eye Size
Water Chilled Fan Coil Unit Data Sheet
| Product Name | Slim exposed FCU | |||||
| Product type | 2-pipe | |||||
| Product models | YG-10/20/30 | |||||
| Application | It is generally used for home, office or hotel, connected with heat pump/chiller or boiler. | |||||
| Product function | It can be used for heating or cooling | |||||
| Power supply | 190-250V 50/60Hz 1PH | |||||
| Condenser | Fin | 0.105mm thickness blue color hydrophilic aluminum fins, FPI 20 | ||||
| Cooper tube | 0.26mm thickness,7mm diameter,pitches 21*12.68mm, 42 copper tubes in 3 rows | |||||
| Drain pan | Material | Steel sheet with Anti-corrosion spraying inside and 6mm insulation on the bottom | ||||
| Product components | Panel | 0.8mm Hot zinc sheet metal with white spray | ||||
| Motor | Low noise five speed DC fan motor | |||||
| Label | Labels: model label, wiring diagram, precautions, fan rotation logo, etc. | |||||
| Fan | ABS+glass fiber material cross flow fan with low noise | |||||
| Tube | Mechanical bending, Mechanical expansion, automatic welding | |||||
| Production technology | Drain pan | One-time molding | ||||
| Body Panel | Fully automatic molding in one molding, with longitudinal reinforcement at the bend,and with high gloss spray surface treatment | |||||
| Motor panel | Hydraulic abrasive ribs+longitudinal reinforcement at the bend | |||||
| Inspection Standards | 1. No scratches or rust on the surface of the machine2. The internal cooler of the machine has no leakage under the pressure of 1.6Mpa(hold pressure for at least 5min)3. The unit starts under the condition of 90% of the rated voltage and runs stably for 10 minutes4.Under normal temperature and humidity conditions, use 500V insulation resistance meter to measure theinsulation resistance between the live part and non-metal live part of the unit is not less than 2MΩ | |||||
| Model | YG-10 | YG-20 | YG-30 | |
| Power supply | 190-250V,50/60HZ,1PH | |||
| Fan speed range | 200-2000RPM | |||
| Air Flow | m3/h | 265 | 420 | 630 |
| Power Input | w | 14 | 16 | 21 |
| Noise (1200RPM) | (dB) A | 34 | 37 | 39 |
| Cooling Cap. (7°C) | KW | 0.9 | 1.68 | 3.36 |
| Heating Cap. (45C) | KW | 0.99 | 1.83 | 3.45 |
| Heating Cap. (60°C) | KW | 1.56 | 3 | 5.65 |
| Water P.D. | Kpa | 12 | 10 | 41 |
| Water Flow | m3/h | 0.2 | 0.3 | 0.61 |
| Net weight | kg | 15.3 | 17.9 | 23.3 |
| Gross weight | kg | 18 | 21 | 27 |
| Packing size | mm | 820*670*185 | 1010*670*185 | 1290*670*185 |
| Noted | 1. All the datas test under the 1200rpm2.The test condition,cooling: DB24°C, WB18.7°C; heating: 20°C | |||
| Model | YG-10 | YG-20 | YG-30 | |||||||||||||
| Fan speed | r/min | 1200 | 1400 | 1600 | 1800 | 2000 | 1200 | 1400 | 1600 | 1800 | 2000 | 1200 | 1400 | 1600 | 1800 | 2000 |
| Air flow | m³/h | 265 | 300 | 340 | 370 | 400 | 430 | 500 | 580 | 660 | 740 | 630 | 750 | 860 | 980 | 1060 |
| Power Input | w | 14 | 19 | 26 | 32 | 35 | 16 | 23 | 32 | 45 | 62 | 21 | 30 | 44 | 63 | 80 |
| Noise | (dB) A | 34 | 38 | 42 | 46 | 48 | 37 | 42 | 45 | 48 | 49 | 39 | 44 | 48 | 49 | 52 |
| Cooling Cap. (7°C) | KW | 0.9 | 1.1 | 1.25 | 1.35 | 1.4 | 1.68 | 1.92 | 2.15 | 2.35 | 2.59 | 3.36 | 3.7 | 4.13 | 4.4 | 4.73 |
| Heating Cap. (45°C) | KW | 0.99 | 1.2 | 1.38 | 1.4 | 1.45 | 1.83 | 2.07 | 2.33 | 2.57 | 2.73 | 3.45 | 3.92 | 4.37 | 4.79 | 5.05 |
| Heating Cap. (60°C) | KW | 1.56 | 1.87 | 2.12 | 2.3 | 2.38 | 3 | 3.35 | 3.74 | 4.15 | 4.5 | 5.65 | 6.38 | 7.12 | 7.77 | 8.24 |
| Water flow | m^3/h | 0.2 | 0.23 | 0.26 | 0.29 | 0.32 | 0.3 | 0.33 | 0.36 | 0.39 | 0.42 | 0.61 | 0.65 | 0.75 | 0.8 | 0.85 |
| Water pressure drop | Kpa | 12 | 12 | 14 | 15 | 16 | 10 | 10 | 12 | 14 | 15 | 41 | 45 | 54 | 63 | 70 |
| Model | YG-10 | YG-20 | YG-30 |
| A Total length | 760 | 950 | 1220 |
| B Air outlet length | 360 | 550 | 820 |
| D Distance between hanging hole | 421 | 611 | 881 |
3 ways of installation
Added small drain pan
The small drian pan can prevent the water from the vent valve or water pipe condensate water drip fell to the floor
Two drain pans in the units,then the units can be installed vertical or horizontal
Thermostat control
Power-off memory function
Water sensor optional
Passive linkage function
Remote control with display
Cold air protection optional
°C and ℉ can be switched at will
5 fan speed adjustable
Product Specification Details Show
| Product Name | Ultra-thin exposed fan coil unit | |||||
| Product type | 2-pipe | |||||
| Product models | FP-34/51/68/85/102/136/170/204 | |||||
| Application | It is widely used for hotel,restaurant,hospital,shopping mall,factory and office building etc. And some other villa. | |||||
| Product function | It can be used for cooling, heating, dehumidification | |||||
| Voltage | 220V | Frequency | 50Hz | |||
| Product components | Condenser | Fin | 0.105mm thickness aluminum fins, distance between fins is 1.3mm | |||
| Cooper tube | Three rows, 0.28mm thickness, 7mm diameter, 30 tubes in total | |||||
| Drain pan | Panel | 0.8 mm thickness, high-gloss spray for strong resistance to corrosion | ||||
| insulation | Thickness 6mm | |||||
| Shell | 0.8mm Hot zinc sheet metal+ABS,not fade | |||||
| Motor | Low noise 3 speed fan motor, long life span | |||||
| Label | Labels: model label, wiring diagram, precautions, fan rotation logo, etc. | |||||
| Fan | ABS material Centrifugal, forward-curved blades | |||||
| Control | LCD thermostat | |||||
| Production technology | Tube | Mechanical expansion, automatic welding | ||||
| Drain pan | One-time molding, high-gloss coating on the surface, thermal insulation on the exterior | |||||
| Body Panel | Fully automatic molding in one molding, with longitudinal reinforcement at the bend | |||||
| Motor panel | Hydraulic abrasive ribs+longitudinal reinforcement at the bend | |||||
| Inspection Standards | 1. No scratches or rust on the surface of the machine2. The internal cooler of the machine has no leakage under the pressure of 1.6Mpa (hold pressure for at least 5min)3. The unit starts under the condition of 90% of the rated voltage and runs stably for 10 minutes4. Under normal temperature and humidity conditions, use 500V insulation resistance meter to measure the insulationresistance between the live part and non-metal live part of the unit is not less than 2MΩ | |||||
| Model | FP-34GQ | FP-51GQ | FP-68GQ | FP-85GQ | FP-102GQ | FP-136GQ | FP-170GQ | FP-204GQ | |
| Cooling capacity(CHW 7℃) | kw | 2.2 | 3.2 | 3.95 | 4.8 | 5.8 | 7.4 | 9.3 | 11 |
| Heating capacity(HW 60℃) | kw | 3.3 | 4.8 | 5.92 | 7.15 | 8.7 | 11 | 13.95 | 16.4 |
| Heating capacity(HW 45℃) | w | 2.2 | 3.2 | 3.95 | 4.8 | 5.8 | 7.4 | 9.3 | 11 |
| Air flow | m³/h | 350 | 560 | 700 | 875 | 1045 | 1410 | 1790 | 2050 |
| Power Input | w | 31 | 40 | 55 | 70 | 83 | 110 | 145 | 180 |
| Noise | dB(A) | 35 | 37 | 39 | 41 | 44 | 45 | 47 | 49 |
| Water Resistance | kPa | 30 | 30 | 30 | 40 | 40 | 40 | 42 | 43 |
| Motor No. | 1 | 2 | |||||||
| Fan No. | 1 | 2 | 3 | 4 | |||||
| Weight | kg | 11 | 15 | 17.2 | 17.9 | 20.6 | 22.5 | 25.8 | 29 |
| Package length | mm | 790 | 940 | 1040 | 1090 | 1290 | 1440 | 1690 | 1890 |
| Package height | mm | 620230 | |||||||
| Package width | mm | ||||||||
| Condenser length | mm | 400 | 550 | 650 | 700 | 900 | 1050 | 1300 | 1500 |
| Condenser hight | mm | 21039 | |||||||
| Condenser thichkness | mm | ||||||||
| Model | FP-34GQ | FP-51GQ | FP-68GQ | FP-85GQ | FP-102GQ | FP-136GQ | FP-170GQ | FP-204GQ |
| A Total length | 752 | 902 | 1002 | 1052 | 1252 | 1402 | 1652 | 1852 |
| B Length of air outlet | 400 | 550 | 650 | 700 | 900 | 1050 | 1300 | 1500 |
| C Distance between liffting holes | 508 | 658 | 758 | 808 | 1008 | 1158 | 1408 | 1608 |
| Height | 550 (630 with feet)180 | |||||||
| Thickness | ||||||||
| Model | FP-34TM | FP-51TM | FP-68TM | FP-85TM | FP-102TM | FP-136TM | FP-170TM | FP-204TM | FP-238TM | |
| Cooling Ca.(Water in 7°℃) | kw | 1.8 | 2.7 | 3.6 | 4.5 | 5.4 | 7.2 | 9 | 10.8 | 12.6 |
| Heating Ca.(Water in 60°C) | kw | 2.7 | 4.05 | 5.4 | 6.75 | 8.1 | 10.8 | 13.5 | 16.2 | 18.9 |
| Air flow | m3/h | 340 | 510 | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 |
| Power Input | w | 37 | 52 | 62 | 76 | 96 | 134 | 152 | 189 | 228 |
| Noise | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 |
| Motor No. | 1 | 2 | ||||||||
| Fan No. | 1 | 2 | 3 | 4 | ||||||
| Static pressure | Pa | 12 | ||||||||
| Condenser length | mm | 450 | 580 | 650 | 760 | 900 | 1100 | 1350 | 1550 | 1750 |
| Condenser height | mm | 200 | ||||||||
| Condenser Width | mm | 65 | ||||||||
| Weight | kg | 13.6 | 16 | 17 | 18.2 | 21 | 26.4 | 31 | 33.7 | 36.6 |
| Package length | mm | 800 | 945 | 990 | 1110 | 1270 | 1460 | 1690 | 1890 | 2070 |
| Package width | mm | 560250 | ||||||||
| Package height | mm | |||||||||
| Unit: mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A Total length | 790 | 940 | 980 | 1100 | 1260 | 1410 | 1680 | 1880 | 2040 |
| B Airoutlet length | 470 | 620 | 660 | 780 | 940 | 1090 | 1360 | 1560 | 1720 |
| C Lifting hole distance | 490 | 600 | 670 | 800 | 920 | 1120 | 1370 | 1570 | 1720 |
| Height of ceiling mounted type | 560640 | ||||||||
| Height of floor standing type | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 | ||
| Air flow | m3/h | 357 | 535 | 714 | 892 | 1071 | 1428 | 1785 | 2090 | 2390 | |
| Cooling Ca.(Water in 7°C) | 3+1 | kw | 1.8+0.6 | 2.7+0.9 | 3.6+1.2 | 4.5+1.5 | 5.4+1.8 | 7.2+2.4 | 9.0+3.0 | 10.8+3.6 | 12.6+4.2 |
| 2+2 | kw | 1.2+1.2 | 1.8+1.8 | 2.4+2.4 | 3.0+3.0 | 3.6+3.6 | 4.8+4.8 | 6.0+6.0 | 7.2+7.2 | 8.4+8.4 | |
| Heating Ca. | 3+1 | kw | 2.7+0.9 | 4.0+1.3 | 5.4+1.8 | 6.7+2.2 | 8.1+2.7 | 10.8+3.6 | 13.5+4.5 | 16.2+5.4 | 18.9+6.3 |
| (Water in 60°C) | 2+2 | kw | 1.8+1.8 | 2.7+2.7 | 3.6+3.6 | 4.5+4.5 | 5.4+5.4 | 7.2+7.2 | 9.0+9.0 | 10.8+10.8 | 12.6+12.6 |
| Water flow | m³/h | 0.32 | 0.478 | 0.64 | 0.797 | 0.956 | 1.275 | 1.594 | 1.913 | 2.323 | |
| Power Input | w | 36 | 50 | 60 | 74 | 93 | 130 | 147 | 183 | 221 | |
| Noise | dB(A) | 37 | 39 | 41 | 43 | 45 | 46 | 48 | 50 | 52 | |
| Static pressure | Pa | 12 | |||||||||
| Condenser length | mm | 470 | 580 | 650 | 780 | 900 | 1100 | 1350 | 1550 | 1700 | |
| Condenser height | mm | 200 | |||||||||
| Condenser Width | mm | 87 | |||||||||
| Package length | mm | 840 | 990 | 1030 | 1150 | 1310 | 1460 | 1730 | 1930 | 2090 | |
| Package width | mm | Vertical type 660/Horizontal type590260 | |||||||||
| Package height | mm | ||||||||||
| Unit: mm | |||||||||
| Model | FP-34 | FP-51 | FP-68 | FP-85 | FP-102 | FP-136 | FP-170 | FP-204 | FP-238 |
| A Total length | 790 | 940 | 980 | 1100 | 1260 | 1410 | 1680 | 1880 | 2040 |
| B Airoutlet length | 470 | 620 | 660 | 780 | 940 | 1090 | 1360 | 1560 | 1720 |
| C Distance between twoHanging Hole | 490 | 600 | 670 | 800 | 920 | 1120 | 1370 | 1570 | 1720 |
| Horizontal type(without feet) | 560640 | ||||||||
| Vertical type High(with feet) | |||||||||
I Wall Hanging Fan Coil Unit
Ultra-slim space-saving design
Intelligent control
Strong environmental adaptability
| MODEL NO. | Power Input | Cooling Cap | Heating Cap | Air Flow | Water flow | Noise |
| FP-2PSY | 33W | 3.5KW | 5.4KW | 680m³/h | 0.75m³/h | 33-45dba |
| Coil Size | Net Size | Package Size | G.W. | |||
| C type680mm | 860*280*195mm | 920*340*280mm | 9.3KG | |||
| MODEL NO. | Power Input | Cooling Cap | Heating Cap | Air Flow | Water flow | Water PD | Noise |
| FP-2PGD | 33W | 3.5KW | 5.4KW | 680m³/h | 0.75m³/h | 38KPa | 33-45dba |
| Coil Size | Net Size | Package Size | N.W. | ||||
| C type680mm | 850*205*265mm | 905*280*345mm | 9.2KG | ||||
| MODEL NO. | Motor | AL fins | Copper Tube | Shell Material | Fan | Control |
| FP-2PSY | Welling brandDC motor | Hydrophilicgolden colorAL fins 19FPI0.105mm thick. | 7*0.32mm28tubes intotal 5 in 5 out | HIPS materialNo color change | Φ96 cross fanHeat-resistingmaterialABS+AS+GF | 1.Fault self-detectioncapabilities2. Cold air protect3.High Temp. protect |
| MODEL NO. | Motor | AL fins | Copper Tube | Shell Material | Fan | Control |
| FP-2PGD | Welling brandDC motor | Hydrophilicgolden colorAL fins19FPI0.105mm thick. | 7*0.26mm28tubes intotal 5 in 5 out | HIPS materialNo color change | Φ96 cross fanHeat-resistingmaterialABS+AS+GF | 1.Fault self-detectioncapabilities2. Cold air protect3.High Temp. protect |
Parameter of Wall Hanging FCU FP-3PJY
| MODEL NO. | Power Input | Cooling Cap | Heating Cap | Air Flow | Water flow | Water PD | Noise |
| FP-2PLY | 33W | 3.6KW | 5.4KW | 680m³/h | 0.75m3/h | 38KPa | 33~38~45dba |
| Coil Size | Net Size | Package Size | N.W. | ||||
| C type650mm | 890*315*188mm | 955*390*245mm | 9.3KG | ||||
Parameter of Wall Hanging FCU FP-2PLY
| MODEL NO. | Power Input | Cooling Cap | Heating Cap | Air Flow | Water flow | Noise |
| FP-3PJY | 35W | 5.42KW | 9.22KW | 1020m³/h | 0.98m³/h | 33~47dba |
| Coil Size | Net Size | Package Size | N.W. | |||
| C type 750mm | 970*315*233mm | 1050*390*315mm | 13.5KG | |||
| MODEL NO. | Motor | AL fins | Copper Tube | Shell Material | Fan | Control |
| FP-2PLY | Welling brandDC motor | Hydrophilicgolden colorAL fins18FPI0.105mm thick. | 7*0.26mm30tubes intotal 5 in 5 out | HIPS material | Φ94 cross fanHeat-resistingmaterialABS+AS+GF | 1.Power cut memoryfunction2. Cold air protect3.High Temp. protect4.Two flap forwindless feeling |
| No color change |
| MODEL NO. | Motor | AL fins | Copper Tube | Shell Material | Fan | Control |
| FP-3PJY | Welling brandDC motor | Hydrophilicgolden colorAL fins 0.105mmthick. | 7*0.32mm32tubes intotal 5 in 5 out | HIPS materialNo color change | 108 cross fanHeat-resistingmaterialABS+AS+GF | 1.Sense and showroom&water Temp.2.Fault self-test3.High Temp. protect |
Dimension Drawing of Wall Hanging FCU FP-2PLY:
I Fan coil unit data sheet
We will provide you detailed product specific about the fan coil units
Brief of the Fan Coil Unit
Cabinet fan coil, mainly composed of fan and coil, suitable for large room with large air volume,efficient heat exchange efficiency, which very popular in the market. Cabinet fan coil unit standingon the corner and does not occupy much space, installation is also very convenient.
Parameter
| Cooling Cap (7C) | Heating Cap (60°C) | Air Flow | Power | Noise |
| 7.5KW | 11.25KW | 1700m³/h | 60W | 48dB(A) |
| Coil Size | Packing Size | GW | ||
| 705*385*45mm | 1840*430*600mm | 35KG | ||
Product Specification Details Show
I Ducted Type High Static Pressure Fan Coil Unit
Unit box This series of fan coil unit panels are made of color steel plate orgalvanized steel plate through compression molding and bending. Cooperate with internal heat preservation and noise elimination materi-als,the appearance is beautiful and elegant. The casing of the unit can be easily and integrally removed, and the installation and maintenance are convenient.
Fan coil unit heat exchanger adopts high-quality 9.52mm copper tube, high-efficiency hydrophilic coated aluminum fin and advanced tube expanding process to make the copper tube and aluminum foil reach the best contact
Large air volume,high efficiency,low noise and large diameter centrifugal fan are adopted to enable the unit to exert the most ideal heat transfer efficiency.
The water-collecting head is forged with brass,which makes the water flow evenly distributed and reduces the pressure loss,further improving the overall heat transfer effect of the fan coil unit.
High flexibility and easy installation and maintenance. It can be applied to a variety of installation modes according to the site conditions,and the unit can be controlled by using a three-speed switch or a fan coilunit temperature controller.
High static pressure design and long-distance air supply can be applied to different places,and different tuyeres are designed according to different places,so that air conditioners are evenly distributed to rooms.
0 air return grille
The indoor unit reduces part of the indoor noise through the optimized design of the air duct, the use of heat preservation and sound insulation materials,and reduces the noise influence on the indoor space again throughthe design of the static pressure box of the project.
Famous brand motor is adopted.Fully enclosed rolling bearing.The base is insulated from vibration by rubber shock pads to reduce running noise.
The product has low noise, stable air supply, invisible installation, and can be connected with air pipe for air supply or directly sent out from the side. Main applicable places:offices, hotels, hotels, hospitals, schools, computer rooms,etc.
| Data unit marked in the figure: mm | ||||||||||||
| MODEL NO. | FP-68H | FP-85H | FP-102H | FP-136H | FP-170H | FP-204H | FP-238H | FP-270H | FP-300H | FP-340H | FP-400H | FP-460H |
| A | 500 | 500 | 500 | 550 | 550 | 620 | 620 | 620 | 620 | 670 | 670 | 670 |
| B | 825 | 825 | 825 | 1000 | 1000 | 1200 | 1200 | 1400 | 1400 | 1400 | 1400 | 1400 |
| C | 260 | 260 | 260 | 315 | 315 | 345 | 345 | 350 | 350 | 400 | 400 | 450 |
| D | 877 | 877 | 877 | 1052 | 1052 | 1252 | 1252 | 1452 | 1452 | 1452 | 1452 | 1452 |
| E | 400 | 400 | 400 | 450 | 450 | 520 | 520 | 520 | 520 | 570 | 570 | 570 |
| L | 675 | 675 | 675 | 850 | 850 | 1050 | 1050 | 1250 | 1250 | 1250 | 1250 | 1250 |
| M | 209 | 209 | 209 | 264 | 264 | 294 | 294 | 299 | 299 | 349 | 349 | 399 |
| N | 185 | 185 | 185 | 240 | 240 | 270 | 270 | 275 | 275 | 325 | 325 | 375 |
| Model NO. | FP-68H F | P-85H F | P-102H F | P-136H F | P-170H F | P-204H F | P-238H F | P-270H F | P-300H | FP-340H | FP-400H | FP-460H | |
| Rated Air flow (m3/h) | 680 | 850 | 1020 | 1360 | 1700 | 2040 | 2380 | 2700 | 3000 | 3040 | 4000 | 4600 | |
| Cooling Cap. (kw) | 3.7 | 4.3 | 4.9 | 7.5 | 9.3 | 11.4 | 12.8 | 14.6 | 15.9 | 17.7 | 20.1 | 22.6 | |
| Heating Cap. (kw) | 5.5 | 6.5 | 7.5 | 11.3 | 13.9 | 16.9 | 19.1 | 22.1 | 24.2 | 26.7 | 30.7 | 34.5 | |
| Coil | Type | Red Copper Tube /Hydrophilic aluminum foil fins | |||||||||||
| Work presssure(MPa | ) 1.6 | ||||||||||||
| Water flow (m3/h) | 0.636 | 0.744 | 0.846 | 1.302 | 1.608 | 1.968 | 2.202 | 2.52 | 2.736 | 3.036 | 3.456 | 3.888 | |
| PD (KPa) | 13.6 | 18.1 | 22.9 | 10.8 | 15.7 | 26.2 | 32.1 | 7.8 | 9 | 8.8 | 11.1 | 12.7 | |
| Fan | Type | Centrifugal Forward Tilting Multi-wing Double-inlet Galvanizing Fan | |||||||||||
| QTY | 2 | ||||||||||||
| MotorInput power (W) | Three-speed single-phase motor | ||||||||||||
| 1 | |||||||||||||
| AC - 220V - 50Hz - 1PHClass B | |||||||||||||
| Insulation grade | |||||||||||||
| 88 | 110 | 143 | 202 | 256 | 278 | 333 | 385 | 485 | 573 | 715 | 860 | ||
| Electric current (A) | 0.4 | 0.5 | 0.7 | 0.9 | 1.2 | 1.3 | 1.5 | 1.8 | 2.2 | 2.6 | 3.3 | 3.9 | |
| ESP (Pa) | 60 | 60 | 60 | 80 | 80 | 100 | 100 | 100 | 100 | 100 | 100 | 100 | |
| Noise (dBa) | 44 | 45 | 47 | 52 | 52 | 56 | 58 | 58 | 60 | 60 | 60 | 62 | |
| Water connection Pipe | 3/4” FPT | ||||||||||||
Product features:
Ceiling, vertical, and horizontal air
conditioning units have the same internal structure, only the installation method is different. The three types of units have the advantages of compact structure, light
weight, convenient operation and simple maintenance.
Air flow ceiling-mounted AHU: 1500\~15000m³/h;
Air flow vertical AHU: 3000\~40,000m³/h.
Product features: Complex structure, many functional segments, and can achieve multiple air treatment functions such as cooling, heating, humidification, and noise reduction.
Air volume range of combined air
conditioning unit:
3000-200000m³/h
Structure&Components&Selection
Structure
Ceiling type, vertical type and horizontal type air conditioning units are mainly composed of profile panel, filter, surface cooler and blower. They are simple in structure and are suitable for places with low air quality requirements.
Structure
The structure of the combined AHU is more complicated, mainly composed of the fresh air section, the return air section, the primary filter section, the medium efficiency filter section, the surface cooling water blocking section, the heating section, the humidification section, the electric heating section, the blower section, and the muffler section. It is composed of middle section, and each functional section can be freely combined to meet the requirements of cold, heat and humidity that require high air quality.
Panel & Frame
Aluminum alloy frame and High quality ABS 3-way connection . Double-skin,two powder coated steel with the insulation betwwen.
Material: polystyrene or polyurethane Also thickness and density cstomized.
Custom components
Components-Filtration
Type: bag Class: F5-F9 Material: Nonwoven fabric
Components-Filtration
Type: steel pipe wound Al / steel fins Heat exchange medium: high temperature water, steam Advantage: easy to clean, not easy to form dust scale, strong anti-corrosion.
Custom components
Components-Filtration
Function of water baffle: In AHU, the water baffle is placed behind the coil and in front of the fan. The purpose is to prevent the airflow from taking away the condensate on the surface of the coil during cooling in summer. It is commonly known as "drifting water" which will have undesirable consequences for the fan&motor.
Components-humidifier section
High-pressure micro-mist humidification:
The water is pressurized by a high-pressure plunger pump, and then atomized by a professional nozzle to achieve the purpose of humidification. Energy-saving and reliable, the humidification range is large, the humidification efficiency is as high as 95%, and the water quality requirements are high.
Electric heating humidification: energize the electric heating tube immersed in water to heat the water to boiling to produce clean steam.
Electrode humidification: Insert an alternating current electrode in the water, use the conductivity of the water to heat and boil to produce steam.
Both humidification methods send steam into the unit through a steam hose
Components-Electric heater
PTC type (recommended):
It is composed of PTC ceramic heating element and Al tube, with low thermal resistance, high heat exchange efficiency, wide voltage application range, non-burning, safe and reliable, super long and durable without oxidation.
Components-Electric heater
Micro-perforated plate muffler:
The thickness of the commonly used metal plate is 1mm, the perforation rate is 1% to 3%, and the hole diameter is less than 1mm.
It is suitable for places with high noise requirements, such as hospitals, schools, libraries, etc.
Generally placed on the rear side of the fan in the AHU to reduce the noise caused by airflow disturbance.
Custom components
Components-Fan&motor
The motor directly drives the impeller, high efficiency, low noise, light weight, compact structure, convenient installation and maintenance, and the air volume range is 1000-20000m³/h
Components-heat recovery
Components-humidifier section
High heat recovery efficiency Occupies large space Easy to get dirty Larger air volume Power supply required
Components-heat recovery
Plate heat exchangers
usually use aluminum foil or fiber materials as the base material to make heat exchange unit bodies, and the corrugated plates of the unit bodies are stacked crosswise. The fresh air can be pre-cooled and dehumidified in summer and pre-heated and humidified in winter, and its heat recovery efficiency can reach to 60%. Therefore, under the premise of ensuring sufficient fresh air replacement in the room, the cooling load and consumption during air conditioning operation are reduced.