PEOPLE
New Energy products ESS Cabinet
PEOPLE ELECTRIC PRODUCT SALES MANUAL
For the people of the world Provide safer electrical products
Top 500 Chinese enterprises and top 500 global machinery enterprises. In 2026, evaluated by the World Brand Lab, the brand value of "People" is 110.927 billion yuan, and it has become one of the 500 most valuable brands in China.
Products have won the highest award in the field of quality in China "National Quality Award" and China Quality Award nomination award, through CCC certification or "S", "CE", "CB" and other international certification, was named "China famous brand products" and "national customer satisfaction products", selling well in more than 125 countries and regions around the world.
More than 100 national key new products, more than 3,000 domestic and foreign patents, more than 5,000 science and technology certificates, the company has reached strategic partnerships with more than 30 institutions of higher learning and technology research and development institutions around the world.
5.0 Intelligent service with customers to establish a comprehensive service network, service hotline: 400-898-1166, we provide from the product unbox inspection, warranty period to provide three guarantees, warranty period to provide lifelong maintenance, on-site equipment installation arrangements to provide technical guidance and other leading services.
FAN COOLING SYSTEM
Intelligent dehumidifcation to eliminate condensation risk
Maintenance-free air-cooled design
| Model | RES-200W100 | RES-215W100 |
| Model | ||
| Battery Type | LiFePO4 | |
| Rated Charge/Discharge Performance | 0.5C | |
| Rated Voltage [V] | 716.8 | 768 |
| Operating Voltage Range [V] | 627.2~817.6 | 672~876 |
| Cell Rated Capacity [Ah] | 280 | 280 |
| Rated Capacity [kWh] | 200.7 | 215.04 |
| Composition | 1P224S | 1P240S |
| Rated Output Power [kW] | 100 |
| Max. Output Current [A] | 159 |
| Rated Grid Voltage [V] | 3/N/PE,230/400 |
| Rated Grid Frequency [Hz] | 50/60 |
| Power Factor Adjustable Range | 1(0.9 Leading~0.9 Lagging) |
| THDi | <3% (@ Rated Power) |
| Rated Output Power [kW] | 100 |
| Max. Output Current [A] | 159 |
| Rated Output Voltage [V] | 3/N/PE,230/400 |
| Rated Output Frequency [Hz] | 50/60 |
| Unbalanced Load Capacity | 100% |
| Ingress Protection | IP54 | |
| Battery Cooling Method | Air conditioning cooling | |
| Relative Humidity | 0~95%,Non-condensing | |
| Temp. Range [°C] | -20~+50 | |
| Altitude [m] | 4000(>2000 Derating) | |
| Communication | RS485/CAN | |
| Communication Protocol | Modbus/IEC104 | |
| Weight [kg] | ≈2250 | ≈2450 |
| Dimension (W*D*H) [mm] | 1550*1235(1050)*2264 | |
| Delivery Method | Integral transportation | |
PV Plant
FAN COOLING SYSTEM
Support remote upgrade & cloud operation and maintenance
| Model | RES-241L120 | RES-261L130 |
| Battery Parameters | ||
| Charge/Discharge Rate | 0.5C | |
| Rated Cell Capacity [Ah] | 314 | |
| Rated Voltage [V] | 768 | 832 |
| Operating Voltage Range [V] | 672~876 | 728~949 |
| Rated Capacity [kWh] | 241.15 | 261.248 |
| Configuration | 1P240S | 1P260S |
| Rated Output Power [kW] | 120 | 130 |
| Max. Output Current [A] | 191 | 206 |
| Rated Grid Voltage [V] | 3/N/PE,230/400 | |
| DC Component | <0.5% In | |
| Rated Grid Frequency [Hz] | 50/60 | |
| Power Factor | 1 (0.9 leading to 0.9 lagging) | |
| THDi | <3% (@ rated power) | |
| Rated Output Power [kW] | 120 | 130 |
| Max. Output Current [A] | 191 | 206 |
| Rated Grid Voltage [V] | 3/N/PE,230/400 | |
| Rated Grid Frequency [Hz] | 50/60 | |
| Unbalanced Load Capabilit | 100% | |
| IP Rating | IP54 | |
| Cooling Method | Air Cooling | |
| Fire Protection System | Aerosol | |
| Relative Humidity | 0~95%, Non-condensing | |
| Temp. Range [°C] | -20~+50 | |
| Max Altitude [m] | 4000 (>2000 Derating required) | |
| Communication Method | RS485, Ethernet | |
| Communication Protocol | Modbus | |
| Weight [T] | ≈2.5 | ≈2.7 |
| Dimensions(W*D*H) [mm] | 1000*1330*2350 | 1000*1370*2350 |
| *Certification | EN62477-1:2012; EN IEC 61000; EN 50549-1/10;NC RfG, PTPiREE, VDE, CEI 0-21, C10/11,NTS,EIFS,TOR,G99,NF EN 50549-1:2019,NF EN 50549-10:2022,EN 50549-1:2019+A1:2023, | |
FAN COOLING SYSTEM
| Model | RES-372L186 | RES-418L209 |
| Battery | ||
| Battery Type | LiFePO4 | |
| Rated Charge/Discharge Performance | 0.5C | |
| Rated Voltage [V] | 1331.2 | |
| Operating Voltage [V] | 1164.8~1497.6 | |
| Cell Rated Capacity [Ah] | 280 | 314 |
| Rated Capacity [kWh] | 372.73 | 417.99 |
| Composition | 1P416S | 1P416S |
| Rated Output Power [kW] | 186 | 130 |
| Max. Output Current [A] | 171 | 206 |
| Rated Grid Voltage [V] | 3/PE,690 | |
| Rated Grid Frequency [Hz] | 50/60 | |
| Power Factor | 1(0.9 Leading~0.9 Lagging) | |
| THDi | <3%(@Rated Power) | |
| Ingress Protection | IP54 | |
| Cooling Method | Battery Compartment (Liquid Cooled)、Electrical Cabin(Air Cooled) | |
| Battery Cooling Method | Liquid cooling system | |
| Fire Protection System | Aerosol/Perfluorohexanone | |
| Relative Humidity | 0~95%,Non-condensing | |
| Temp. Range [°C] | -20~+50 | |
| Altitude [m] | 4000(>2000 Derating) | |
| Communication | RS485、CAN | |
| Communication Protocol | Modbus、IEC104 | |
| Weight [kg] | ≈3600 | ≈3750 |
| Dimension (W×D×H) [mm] | 1325*1375*2300 | 1325*1375*2300 |
| Delivery Method | Integral transportation | |
FAN COOLING SYSTEM
All-in-one design for easy transportation and installation, flexible deployment
Multiple capacity designs Meets the needs of multiple applications
Separation of electrical and battery compartments to prevent thermal runaway from spreading
Supports PV DC access
| Model | RES-H10-482L250C-PS | RES-H10-723L250C-PS |
| Battery Parameters | ||
| Charge/Discharge Rate | 0.5C | |
| Rated Battery Cell Capacity [Ah] | 314 | |
| Rated Voltage [V] | 768 | |
| Operating Voltage Range [V] | 672~876 | |
| Rated Energy [kWh] | 482 | 723 |
| Configuration | (1P240S) *2P | (1P240S) *3P |
| AC Parameters (On Grid) | ||
| Rated Output Power [kW] | 250 | |
| Rated Output Current [A] | 360 | |
| Rated Grid Voltage & Range [V] | 3W/N/PE,230/400 | |
| Rated Grid Frequency [Hz] | 50/60 | |
| Power Factor | 1 (0.9 leading to 0.9 lagging) | |
| THDi | ≤3% (@ rated power) | |
| AC Parameters (Off Grid) | ||
| Rated Output Power [kW] | 250 | |
| Rated Output Current [A] | 360 | |
| Rated Output Voltage [V] | 3W/N/PE,230/400 | |
| Rated Output Frequency [Hz] | 50/60 | |
| Unbalanced Load Capability | 100% | |
| PV Input (PV Integration via Optional Side Cabinet) | ||
| PV Max. Input Power [kWp] | 360 | |
| MPPT Max. Number | 6 | |
| PV Input Voltage Range [V] | 200~660 | |
| PV Max. Input Current [A] | 6*150 | |
| General Parameters | ||
| Isolation Transformer | Yes | |
| IP Rating | IP54 | |
| Cooling Method | Battery Compartment (Liquid-Cooled)/Electrical Compartment (Air-Cooled) | |
| Fire Suppression System | Cabinet-level Fire Suppression | |
| Relative Humidity | 0~95%, Non-condensing | |
| Temp. Range [°C] | -20~+50 | |
| Max. Operating Altitude [m] | 4000 (>2000 Derating required) | |
| Communication Interface | CAN / RS485, Ethernet | |
| Communication Protocol | Modbus/IEC104 | |
| Weight [T] | ≈8.1 | ≈9.8 |
| Dimensions(W*D*H)[mm] | 2991*2438*2896 | |
PV+ESS+Charging Microgrid
FAN COOLING SYSTEM
Multi-protection design Higher security
| Model | LBS-4180-HV-G20 | LBS-5016-HV-G20 |
| Battery | ||
| Rated Charge/Discharge Performance | 0.5C | |
| Battery Capacity [Ah] | 314 | |
| Battery Rated Voltage [V] | 1331.2 | |
| Operating Voltage Range [V] | 1164.8~1497.6 | |
| Rated Capacity [kWh] | 4179.97 | 5015.96 |
| System Battery Configuration | (1P416S)*10P | (1P416S)*12P |
| General Parameters | ||
| Ingress Protection | IP54/IP55 | |
| Cooling Method | Liquid Cooling | |
| Fire Fighting System | Aerosol | |
| Relative Humidity | 0~95%, Non-condensing | |
| Operating Temperature [°C] | -20~+50 | |
| Altitude [m] | 4000(>2000 Derating) | |
| Communication | CAN/RS485/Ethernet | |
| Communication Protocol | Modbus/IEC104/IEC61850 | |
| Weight [T] | ≈37 ≈42 | |
| Dimension (W*D*H) [mm] | 6058*2438*2896 | |
| Product Certifications | ||
| Certificates | IEC 62619,IEC 62477,IEC 63056,IEC 61000,UL 1973,UL 9540A,NFPA 855 | |
| Safe Transportation | UN3536、UN38.3 | |
| Model | REG-2500K-UD-35 | REG-3450K-UD-35 | REG-5000K-UD-35 |
| AC Side Parameters | |||
| Rated Output Power [kW] | 2500 | 3450 | 5000 |
| Rated Output Voltage [kV] | 6~35 | ||
| Rated Output Frequency [Hz] | 50/60 | ||
| Power Factor | 1 (0.9 Leading - 0.9 Lagging) | ||
| Transformer Parameters | |||
| Rated Capacity [kVA] | 2500 | 3450 | 5000 |
| Voltage Transformation Ratio [kV/kV] | 0.69/6~35 | ||
| Connection Group | DY11 | ||
| Transformer Type | Dry Type/Oil-immersed | ||
| General Parameters | |||
| Ingress Protection | IP54/IP55 | ||
| Cooling Method | Forced Air Cooling | ||
| Relative Humidity | 0~95%,Non-condensing | ||
| Operating Temperature [°C] | -20~+50 | ||
| Altitude [m] | 4000 (>2000 Derating) | ||
| Communication | CAN/RS485/Ethernet | ||
| Communication Protocol | Modbus/IEC104/IEC61850 | ||
| Weight [T] | ≈16 | ≈17 | ≈22.5 |
| Dimension (W*D*H) [mm] | 6058*2438*2896 | 12192*2438*2896 | |