SUZHOUSUSHI Testing Group
Aboutus
Suzhou Sushi Testing Group CO., LTD. (stock code: 3004l6,referred to as "ssT") is a leading domestic and internationallyrenowned provider of industrial product environmental adaptability and reliability test verification and analysis service solutions.Since its establishment in l956,sST has been working hard in the field of environment and reliability testing,focusingonimproving thereliability of industrial product and boosting the highquality development of the industry.SST is strivingtobecometheleaderintheresearch and developmentof domestic environment and reliability testing equipment,and an importantcontributortotheimprovementof industrial product quality and reliability.
TheformerSuzhou GeneralFactoryofTesting Instrumentswas foundedin1956,andonJanuary222015,thecompany waslistedontheGEMboardofthe Shenzhen Stock Exchange,with stock code:300416.In2019,sSTacquiredChongqing SDElto furtherexpandtheproductioncapacityoftestinginstrument,andinthesameyear,SSTacquiredShangaisT to enter the field of IC services,with the ability to provideafullindustrial chainof testing services.
MAINBUSINESS STRUCTURE
n
25+ CHAIN LABORATORIES WORLDWIDE
n
3+ DEVELOPMENT BASE
TestInstrument
Test Service
·Mechanical environment test system
·Climate environment test system
·Combined environment test system
·Analysis system
·Sensor
·Environmental test
·Reliability test
·Emc test
·Performance test
·Material test
·Software test
·Field test
· Integrated circuit verification and analysis
·Electronic test and certification
| THV Series Temperature, Humidity and Vibration Combined Test System P.01 |
| Smart-Ol Temperature and Humidity Controller P.11 |
| WI Series Walk-in Test Chamber P.13 |
| HH Series Highly Accelerated Life Test and Stress Screening System (HALT&HASs) P.15 |
| HHED Series Electric Highly Accelerated Life Test and Stress Screening System P.17 |
| ATHV Series Vibration,Temperature, Humidity,Low Pressure Combined Environmental Test System P.19 |
| CTSSeries VehicleTestChamber P.21 |
| KMT Series Thermal Vacuum Test Chamber P.23 |
| SDK/SDL/SDE Series Environmental Stress Screening Chamber P.25 |
| SDP Series High and Low Temperature Test Chamber P.29 |
| TSM Series Temperature Shock Chamber (Two Chamber Shock) P.31 |
| TSD Series Temperature Shock Chamber (Three Chamber Shock) P.33 WG/DGT/DGF/Cs Series High Temperature Oven, Blast Drying Oven P.35 |
Temperature,Humidityand Vibration CombinedTest System
The THV series combined environmental test system is a high-end test equipment developed by SSTusing its professional experienceand technical trength in thefieldofenvironmentaland reliabilitytest.Itcan fullysimulatea variety of environmentalfactorsand provide customers with accurateenvironmentaladaptationand reliability test services.
The THV series combined environmental test system can provide α comprehensive test solution from single environmental stress tocomplex multi-stress combination.Byintegrating multiple environmental factors such as temperature,humidityand vibration,the systemcansimulate theproductduring transportation,storageanduseat various extreme environmental conditions that may be encountered.
Large combined system using procedure
of the corresponding workstation
05
04
品
The coordination process of horizontal workstation and blind plate workstation is the same
5
Close the chamber door,and use themotor to drive the screw rod to liftthechamber to complete the coordination
| SST Combined Test System | Common Combined Test System | |||
| Systematic special design tailored to vibration shaker and test chamber | Subsystems designed separately, leading to low communication efficiency and possible design oversights | |||
| System Manufacturing | Entire system manufacturing coordinated by SST,delivery time controllable | Manufacturing and delivery dates uncontrollable | × | |
| System Coordination | *System fully coordinated and debugged before factory shipment *Omissions repaired on-site at factory *Ensures improved delivery efficiency | * Subsystems made by different companies * First-time installation at customer site * Prone to mismatching issues * Significantly impacts delivery efficiency to customers | X | |
| System Usage | * SST leverages long-term laboratory experience * Systematically addresses long-term reliability issues * Aims to extend equipment service life | requirements at delivery * Long-term use may reveal issues from design omissions Examples: * Condensation on table surface during extended low-temperature tests * Condensed water infiltrates slip table oil tank *These issues reduce slip table service life | × | |
| Easy Installation | * Based on long-term lab experience, SST adopts an integrated solution * First install specimen and fixture, then move the test chamber * This approach simplifies user installation and operation | * Customer convenience for specimen and fixture installation was overlooked | ||
| System Structure | * SST holds multiple structural and appearance patents * Features beautiful design,compact structure * Smooth lifting mechanism * Convenient operation and high safety | * Traditional combined chambers use fixed, hydraulic vehicle lifting,or external frame gantry structures These have drawbacks: * Inconvenientoperation and ifting/lowering * Bulky, bloated structure * Low safety | × | |
| System Control | *Controls vibration, temperature, and humidity * Displaysand exportsdataonaunified software interface | * Temperature, humidity,and vibration controlled by separate systems * Interfaces have inconsistent styles and operating habits * Test data must be exported separately from each system | × | |
01 N1 Integrated Control Test settings,parameter display,and curve recording allin one software interface.
N Strong Scalability 04 Supports multiple interface connection methods for vibration shaker and chamber,enhancing flexibility and adaptability.
02 Timeline Consistency Precise synchronization of vibration, temperature,and humidity timelines for easymonitoringanddataretrieval.
N5 Digitall/O Ports
Standard 8-way digital input/output ports enable control and monitoring of external devices (sensors,switches),boosting automation and intelligence of tests.
03 Easy to Use Real-time preview of setting conditions on the timeline during test setup,enhancing user-friendliness for complex test conditions.
CEC-3000SERIES
CEC-3ooo Vibration, Temperature and Humidity CombinedController
CEC-3000 isacontrollerspeciallydevelopedforcombinedtests.Theobjectsofcontrolarevibrationshakerrefrigeration unit,heatingcomponentandhumidificationcomponent.CEC-3o0integrates multiplefunctionsofcontrol,signal acquisition and signal analysis.It is the first integrated controller in China.
Hardware
| Vibration Part | |
| Number Of Input Channels | Standard 4Channels |
| Connection | BNC |
| Coupling Mode | AC,DC,IEPE,Charge |
| Input Dynamic Range | 100dB |
| Sampling Rate | Up to 102.4 kHz |
| Power Supply | External DC Power Supply |
| Communication | Network |
| Temperature and Humidity Part | |
| Number of Input Channels | Standard 4 Channels |
| Sensor Type | T-type Thermocouple or PT100 |
| Power Supply | External DC Power Supply |
| Communication | Network |
| THVSeriesTemperature nbiat ombined Test Temperature fluctuation C | ystemTecnnicalParameter(Chamber) ±0.5 ±2 | ||||||||||
| Temperature deviationC Temperature uniformity C | ≤2 | ||||||||||
| Humidity range %RH Humidity deviation %RH | 20~98 | ||||||||||
| ≤75%RH:≤±5%;>75%RH:≤+2-3% +4~89.5 | |||||||||||
| Dew point temperature℃C | 3/N/PEAC,380V±10%,50Hz | ||||||||||
| Power supply | |||||||||||
| Test chambermodel/volume L | THV-600 | ||||||||||
| Test area dimension mm Load | 800W×800D×1000H | ||||||||||
| Temperature rangeC | 25kg aluminum ingot | ||||||||||
| Temperature change assessment range C | -70~+180 | ||||||||||
| -40~+85 | -55~+85 | ||||||||||
| Heating and cooling rate C/min | 5 10 | 15 | 2 | 5 | 10 | 15 | 2 | 5 | 10 | 15 | |
| Rated Power kW | 2 9 | 12 | 19 | 25 | 9 | 17 | 23 36 | 7 | 10.5 | 1 | 1 |
| Cooling circulating water flow t/h | 2.6/N3.4/N | 6.2 | 5.5 | 5.8 | |||||||
| 10.6 | 2.1/N | 9.7 THV-1200 | 14 | 2.3 | 1 | ||||||
| Test chamber model/volume L Test area dimension mm | |||||||||||
| Load | 1100W×1100D×1040H | ||||||||||
| Temperature range℃ | 50kg aluminum ingot | ||||||||||
| Temperature change assessment rangeC | -70~+180 | -40~+180 | |||||||||
| Heating and cooling rateC/min | -40~+85 | 2 | -55~+85 | 5 | 10 | 15 | |||||
| Rated Power kW | 2 | 5 10 19 25 | 15 39 | 5 21 | 10 36 | 15 43 7.9 | 2 | 13.9 | 一 1 | ||
| 9 10 | |||||||||||
| Cooling circulating water flow t/h | 2.6/N 6.2 10.6 16.1 2.9 6.8 | ||||||||||
| Test chamber model/volume L | THV-2200 | ||||||||||
| Test area dimension mm | 1400W×1400D×1100H | ||||||||||
| Load | 100kg aluminum ingot | -40~+180 | |||||||||
| Temperature rangeC | -70~+180 | ||||||||||
| Temperature change assessment rangeC | -40~+85 | -55~+85 | 15 | ||||||||
| Heating and cooling rateC/min | 2 | 5 | 10 15 | 2 | 5 | 10 | 15 | 2 | 5 16.6 | 10 1 | |
| Rated Power kW | 12 | 23 | 39 56 | 17 | 28 | 52 | 75 | 10.5 | 一 | ||
| Cooling circulating water flow t/h | 3.4/N | 7.7 16.1 | 20.9 | 5.5 | 12 | 19.8 | 27.3 5.8 | 8.4 | 1 | 1 | |
| Testchambermodel/volumeL | THV-3300 | ||||||||||
| Test area dimension mm | 1500W×1500D×1500H | ||||||||||
| Load | 150kg aluminum ingot | ||||||||||
| Temperature range℃ | -70~+150 | -40~+150 | |||||||||
| Temperature changeassessment rangeC | -40~+85 | -55~+85 | 1 | ||||||||
| Heating and cooling rateC/min | 2 | 5 10 | 15 | 2 | 5 | 10 | 15 2 | 5 | 10 | 15 | |
| Rated Power kW | 19 | 30 46 | 67 21 | 36 63 | 87 | 13.9 | 20 | 1 | |||
| Cooling circulating water flow t/h 6.2/N | 12.4 18.5 | 26.56.8/N | 14 23 | 30.7 | 6.4 | 10 | 一 | 1 | |||
| Test chamber model/volume L | THV-4800 | ||||||||||
| Test area dimension mm | 1800W×1800D×1500H | ||||||||||
| Load | 150kg aluminum ingot | ||||||||||
| Temperature rangeC | -70~+150 | ||||||||||
| Temperature changeassessment rangeC | -40~+85 | -55~+85 | -40~+150 | ||||||||
| Heating and cooling rateC/min | 2 | 5 | 10 | 15 2 | 5 | 10 87 | 2 13.9 | 5 24.6 | 10 15 1 1 | ||
| Rated Power kW Cooling circulating water flow t/h | 23 7.7/N | 39 16.1 | 81 93 29.5 34 | 23 9.7 | 43 16.1 | 126 30.7 46 | 6.4 | 11.7 | 1 1 | ||
| Testchambermodel/volumeL | ||||||||||||||
| Test area dimension mm Load | 1800W×1800D×1800H/2000W× 2000D×1500H 200kg aluminum ingot | |||||||||||||
| Temperature range℃ | -70~+150 | -40~+150 | ||||||||||||
| Temperature change assessment range ℃ 2 | -40~+85 | -55~+85 | 一 | |||||||||||
| Heating and cooling rate C/min | 5 | 10 | 15 | 2 | 5 | 10 | 10 | 2 | 5 | 10 | 15 | |||
| Rated Power kW | 25 | 46 | 81 | 134 | 28 | 52 | 87 | 150 | 17.2 | 30 | 1 | 1 | ||
| Cooling circulating water flow t/h | 18.5 | 29.5 | 53 | 12 | 19.8 30.7 | 54.6 | 7.4 | 13.6 | 1 | |||||
| 10.6 | THV-8000 | |||||||||||||
| Test chambermodel/volume L | ||||||||||||||
| Test area dimension mm Load | 2000W×2000D×2000H | |||||||||||||
| Temperature rangeC | 200kg aluminum ingot | -40~+150 | ||||||||||||
| Temperature change assessment rangeC | -40~+85 | -70~+150 | -55~+85 | |||||||||||
| Heating and cooling rateC/min | 2 | 5 | 10 | 15 | 2 5 | 10 | 15 | 2 | 5 | 10 | 15 | |||
| Rated Power kW | 25 | 46 | 93 | 162 | 28 63 | 126 | 174 | 17.2 | 一 | 一 | ||||
| Cooling circulating water flow t/h | 10.6 | 18.5 | 34 | 59 | 12 | 23 | 46 | 61.4 | 7.4 | 1 1 | 1 | 一 | ||
| Testchambermodel/volume m³ | THV-10 | |||||||||||||
| Test area dimension mm Load | 2300W×2300D×2000H | |||||||||||||
| Temperature rangeC | 200kg aluminum ingot -70~+150 | -40~+150 | ||||||||||||
| Temperature change assessment range ℃C | -40~+85 | |||||||||||||
| Heating and cooling rateC/min | 2 | 5 10 | 15 | 2 | 5 | 10 | 15 | 2 | 5 | 10 | 15 | |||
| Rated Power kW | 67 134 | 200 79.5 | 36 | 75 | 150 | 1 | 20 | 1 | 一 | 一 | ||||
| 39 Cooling circulating water flow t/h 16.1 | 7.9 | 1 | 1 | |||||||||||
| Test chamber model/volume m³ | 26.5 53 14 27.3 54.6 1 | |||||||||||||
| Test area dimension mm | THV-12 | 2200W×2200D×2600H/2500W×2500D×2000H | ||||||||||||
| Load | 200kg aluminum ingot | |||||||||||||
| Temperature range℃ | -70~+150 | -40~+150 | ||||||||||||
| Temperature change assessment range C | -40~+85 | -55~+85 | ||||||||||||
| Heating and cooling rateC/min | 5 | 10 | 15 | 2 5 | 10 | 15 | 2 | 5 | 10 | 15 | ||||
| Rated Power kW | 67 | 134 | 200 | 36 | 75 | 150 | 1 | 20 | 1 | 1 | 一 | |||
| Cooling circulating water flow t/h | 39 16.1 14 27.3 | 26.5 53 79.5 | 1 | 一 | ||||||||||
| Test chamber model/volume m³ | 54.6 1 7.9 THV-18 | |||||||||||||
| Test area dimension mm | 3000W×3000D×2000H | |||||||||||||
| Load | 250kg aluminum ingot | |||||||||||||
| Temperature rangeC | -70~+150 | -40~+150 | ||||||||||||
| Temperature change assessment rangeC | -40~+85 2 | -55~+85 10 | 15 | 5 | 10 | 15 | ||||||||
| Heating and cooling rateC/min Rated Power kW | 15 2 5 186 52 104 | 5 10 81 162 | ||||||||||||
| THV 600 | THV 1200 | THV 2200 | THV 3300 | THV 4800 | THV 5800 | THV 6000/8000 | THV 10 | THV 12(2222) | THV 12(2525) | THV 18 | THV 24 | |
| DC-1000/SV-0505 | 。 | 。 | ||||||||||
| DC-1000/SV-0606 | ||||||||||||
| DC-1000/SV-0808 | ||||||||||||
| DC-2200/SV-0505 | 。 | |||||||||||
| DC-2200/SV-0606 | ||||||||||||
| DC-2200/SV-0808 | ||||||||||||
| DC-3200/ST-1010 | 。 | |||||||||||
| DC-3200/ST-1212 | 。 | · | ||||||||||
| DC-3200/SV-0505 | ||||||||||||
| DC-3200/SV-0606 | ||||||||||||
| DC-3200/SV-0808 | ||||||||||||
| DC-3200/SV-1010 | · | 。 | ||||||||||
| DC-3200/SV-1212 | 。 | · | ||||||||||
| DC-4000/ST-1010 | 。 | |||||||||||
| DC-4000/ST-1212 | ||||||||||||
| DC-4000/SV-0505 | . | |||||||||||
| DC-4000/SV-0606 | ||||||||||||
| DC-4000/SV-0808 | ||||||||||||
| DC-4000/SV-1010 | · | 。 | ||||||||||
| DC-4000/SV-1212 | 。 | |||||||||||
| DC-5000/ST-1010 | ||||||||||||
| DC-5000/ST-1212 | ||||||||||||
| DC-5000/ST-1515 | ||||||||||||
| DC-5000/ST-2020 | 。 | |||||||||||
| DC-5000/SV-0505 | 。 | |||||||||||
| DC-5000/SV-0606 | · | |||||||||||
| DC-5000/SV-0808 | 。 | |||||||||||
| DC-5000/SV-1010 | ||||||||||||
| DC-5000/SV-1212 | 。 | |||||||||||
| DC-5000/SV-1515 | ||||||||||||
| DC-6000/ST-1010 | 。 | |||||||||||
| DC-6000/ST-1212 | 。 | 。 | 。 | |||||||||
| DC-6000/ST-1515 |
| THV 1200 | THV 2200 | THV 3300 | THV 4800 | THV 5800 | THV 6000/8000 | THV 10 | THV 12(2222) | THV 12(2525) | THV 18 | THV 24(3030)|24(3535) | THV | |
| DC-6500/ST-1010 | 。 | |||||||||||
| DC-6500/ST-1212 | ||||||||||||
| DC-6500/ST-1515 | ||||||||||||
| DC-6500/ST-2020 | ||||||||||||
| DC-6500/SV-0505 | ||||||||||||
| DC-6500/SV-0606 | 。 | |||||||||||
| DC-6500/SV-0808 | ||||||||||||
| DC-6500/SV-1010 | 。 | |||||||||||
| DC-6500/SV-1212 | 。 | 0 | ||||||||||
| DC-6500/SV-1515 | ||||||||||||
| DC-7500/ST-1010 | ||||||||||||
| DC-7500/ST-1212 | 。 | 。 | ||||||||||
| DC-7500/ST-1515 | 。 | |||||||||||
| DC-7500/ST-2020 | ||||||||||||
| DC-7500/SV-0505 | ||||||||||||
| DC-7500/SV-0606 | 。 | |||||||||||
| DC-7500/SV-0808 | 。 | |||||||||||
| DC-7500/SV-1010 | ||||||||||||
| DC-7500/SV-1212 | ||||||||||||
| DC-7500/SV-1515 | ||||||||||||
| DC-12000/ST-1010 | ||||||||||||
| DC-12000/ST-1212 | ||||||||||||
| DC-12000/ST-1515 | ||||||||||||
| DC-12000/ST-2020 | ||||||||||||
| DC-12000/ST-2525 | ||||||||||||
| DC-12000/SV-0808 | 。 | |||||||||||
| DC-12000/SV-1010 | ||||||||||||
| DC-12000/SV-1212 | 。 | |||||||||||
| DC-12000/SV-1515 | ||||||||||||
| DC-20000/ST-1515 | 。 | |||||||||||
| DC-20000/ST-2020 | ||||||||||||
| DC-20000/ST-2525 | ||||||||||||
| DC-20000/SV-1515 |
C
SMART-01
Temperature andhumidity controller
Smart-0lisatemperatureandhumiditycontrolsystem independentlydevelopedbySST,builtonanindustrial-grade intelligentPore.Itrsgelablitytabilitystomatidlbilityithserfrdlyratioiple communicationoptions,remotemonitoringanddataacquisition,Smart-0lis widelyusedinssT'snvironmental test products,including temperatureandhumiditychambers,combined chambers,walk-inchambers,andvehicle test chambers.
Interface display function introduction
30.1 94.9 M B MAN
System Main Menu
Displays the running program number, number of steps, remaining time, number of cycles and cumulative running time of the device.
Running Curve
The operation trend curve is displayed.The limit coordinate axis of time, temperature and humidity are adjustable,and the graph can be enlarged or reduced.
Program Selection
Canselect value run or program run.
Program Editing
Set the program steps to run and preview the program graphic curve
System Operation Status
Display the system's operating conditions to facilitate system monitoring, detection and maintenance.
Alarm
Displays the fault alarm type and provides alarm solutions.
| Beautiful interface | 10.1/15.6-inch LCD display,resolution 1280 × 800P/1920 × 1080P |
| User-friendly | Human-machine interaction mode (HMl),using touch input and control. WiN10 operating system. |
| Language | Can switch to English to cope with different language environments. |
| Power off memory | The power failure recovery mode can be set to stop,start,and pause. |
| Multi-level permission account | Allow more than 20 different users to use 3 different security permissions to fully ensure the security of the system. |
| Intelligenttemperaturecontrol | The default temperature control mode is air temperature control,and the sample detection temperature control mode is optional. |
| Dewpointautomaticcontrolfunction | Automatically manage air dew point to prevent condensation on the surface of the specimen. |
| Communicationinterface | The built-in LAN port supports Ethernet, ModbusTCP,3G/4G and other communication methods. |
| Can be connected to computer for curve display,data acquisition and remote monitoring. | |
| Can be connected to Ethernet via professonal software and hardware to achieve remote control and assistance over the network. | |
| Optional hardware is available to support common communication methods such as RS-485 and RS-232. | |
| Data storage and reading | Historical curves, data,control parameter,alarm documents,etc.can be downloaded via USB flash drive. |
| Built-in large storage space, cyclic memory storage of I2 months of historical curves and data. | |
| Programcapacity | Fixed value running time setting: the default maximum is 320oo min (can also be set to continuous operation with no time limit). |
| Usable single program capacity: 100 steps per group. | |
| Available memory program capacity: Maximum 100 groups,totaling 10,oo0 steps. | |
| Executable program loop commands: Each command can be cycled up to 32,0oo times. | |
| Supports for linking program functions. |
C
WISERIES
Walk-inTestChamber
Walk-in testchambersareused in theautomotiveparts,electronicdevices,plastics,chemicals,and pharmaceutical industriesfor heatresistance,coldresistanceandhumidityresistancetest,providingatemperatureandhumiditytest environment for large parts,semi-finished products and finished products.
Note:
1.Temperaturechangerate temperature,range,humidityandotherparametercanbecustomizedaccording to needs;
2. High and low temperature chamber(No humidity) can be highly customized;
3.The volume and size of the test chamber can be customized according to needs;
4.Product manufacturing standards meet IEC 60o68-3-5,JJF 1101.
| Testchambermodel | 9 | 11 | ||
| Test area dimension width mm | 2200 | 2200 | ||
| Test area dimension depth mm | 2100 | 2100 | ||
| Test area dimension high mm | 2000 | 2300 | ||
| Temperature fluctuationC | ||||
| Temperature deviation℃ | ||||
| Temperature uniformity C | ||||
| Temperature rangeC | ||||
| Temperature change assessment rangeC | ||||
| Heating and cooling rateC/min | ||||
| Humidity range %RH | ||||
| Humidity deviation %RH | ||||
| Dew point temperatureC | ||||
| Power supply | ||||
| Rated power kW | 19 26 | 20 | 37 | 22 |
| Cooling circulation water flow+30oC t/h | 8 10 | 8 | 12 | 9 |
| 14 | 16 | 18 | 21 | ||||
| 2200 | 2200 | 2200 | 2200 | ||||
| 3100 | 3100 | 4100 | 4100 | ||||
| 2000 | 2300 | 2000 | 2300 | ||||
| ±0.5°℃ | |||||||
| ±2°C | |||||||
| ≤2°C | |||||||
| -40~+120/-60~+120 | |||||||
| -25~+105/-40~+100 | |||||||
| 2(customizable) | |||||||
| 20~98 | |||||||
| ≤75%RH:≤±5% | |||||||
| >75%RH:≤+2-3% | |||||||
| -3~89.5 | |||||||
| 3/N/PEAC,380V±10%,50Hz | |||||||
| 42 | 24 | 45 | 25 | 47 | 34 | 47 | |
| 16 9 | 18 | 10 | 19 | 12 | 19 | ||
Highly Accelerated Life Test and Stress Screening System (HALT&HASS)
Highly AcceleratedLifeTesting(HALT)isareliabilitytestthatapplies extreme stress-suchasrapid temperaturechanges and high-level vibrations-beyond normaloperatingconditions.Itsgoal is toquicklyreveal potentialfailurepoints helping toidentifyaproduct'soperatingand destructive limits earlyin developmentand improveoveral reliability
应回
Analyze and Improve Product Design Limits
ContinuousAssessmentof Product Improvements
Quickly Find Designand Damage Limits
Improve Product Quality and Reliability
Eliminate Design Defectsand Reduce Early Failure Rates
Reduce R&D and Production Time and Costs
System Composition
HC-3000 controller
&
Three-axis Six DoF Vibration Assembly(
The vibration assembly uses compressed air as power source and consists of an exciter, a vibration table and a support system.
The HC-30o0 controller is designed specifically for Highly Accelerated Life Testing (HALT) and Stress Screening (HAss). It integrates control, signal acquisition,and analysis functions. The system preciselymanages air hammer force, liquid nitrogen flow, and electric heating. It also offers accurate temperature measurement and broadband random spectrum analysis.
5 Rapid temperature change test chamberi
Thetestchamberuses high-efficiencynickel-chromium alloyheatingwireand liquidnitrogenrefrigerationto achieve rapid temperature change
əTemperature and vibration integrated controller o Temperature and vibration are controlled by HC-3000
Test Methods That The System Meets
Testmethods available for highly accelerated life test and stress screening test systems
Vibration Step, Cycle
Vibration and Temperature Combined Test
Temperature Shock, Step,Cycle
| Model | HH-610 HH-900 HH-1200 | ||
| Temperature range | -100~+200°℃ | ||
| Temperature change rate | 70C/min | ||
| Refrigerationmethod | Liquid nitrogen | ||
| Flow rate L/min | 13 | 24 | 34 |
| Frequency range | 10~10000Hz | ||
| Vibration Level Grms | 5~100 | 5~100 | 5~100 |
| Table load kg | 45 | 150 | 200 |
| Table dimension mm | 610×610 | 900×900 | 1200×1200 |
| Working space mm | 850W×850D×500H | 1140W×1140D×900H | 1400W×1400D×1050H |
| Overall dimension mm | 1340W×1114D×1900H | 1415W×1650D×2250H | 1930W×1700D×2860H |
| Power supply | 3/N/PEAC,380V±10%,50Hz | ||
| Controller | HC-3000 | ||
Product Introduction
Theelectro-dynamic high acceleratedlife test and stress screening system consists of ahigh accelerationelectrodynamicvibration shaker,arapid temperature change test chamberand an integrated temperature and vibration controller.
Electro-dynamic Highly Accelerated Life Testand Stress ScreeningSystem
System Composition
| Model HHED-600 | HHED-1200 HHED-2200 | ||
| Temperature range | -100~+200°℃ | ||
| Temperature change rate | 70℃/min | ||
| Refrigeration method | Liquid nitrogen | ||
| Flow rate L/min | 28 | 35 | 46 |
| Workspace mm | 800W×800D×1000H | 1100W×1100D×1040H | 1400W×1400D×1100H |
| Power supply | 3/N/PEAC,380V±10%,50Hz | ||
| Vibration shaker model | ☆DC-3200~DC-12000 | ||
| Controller | CEC-3000 | ||
Note:
ATHVSERIES
LowPressure,Temperature,Humidity,Vibration Combined Test System
It usesrollingsealandarmatureself-centering technologies,integratingtemperature,humidityvibration,and high-altitude low-pressure stress tests into a combined environmental stress test system.
Flexible Parameter Settings
During testing,temperature,humidityration,irpressuredelectricalstressesreppliedtotheimen either simultaneously or separately in specified combinations and cycles.
RealisticSimulation
Comparedto single-stresstests,itofers more realistic environmentalsimulationand higher testing efficiency.
Wide Application
Itis usedinerospace,specialvehicles,andotherindustries toevaluateandcertifythereliabilityanddaptability of electronic products.It also helps identify design and process defects earlyin the development stage.
The Vibration Shaker Works Stably
The vibration shaker features a full sealed design with adjustable internal air pressure to counteract suction forces caused by pressre changes in the test chamber.This ensures the armature remains centered and the shaker operates smoothly.
Note:
1.Water supply temperature:Water temperature of 5 ^ { \circ } { \mathsf { C } } { ~ } 2 8 ^ { \circ } { \mathsf { C } } can meet the usage requirements.Water temperature of 2 8 ^ { \circ } { \mathsf { C } } { ~ } 3 3 ^ { \circ } { \mathsf { C } } can be used normally, but the cooling time will vary.
2.The specifications of the vibration table can be customized.
3.Overllibdtt be slightly adjusted due to differences in compressor configuration.
| Model | ATH-1000 | ATH-3300 | ATH-8000 | ATH-12 |
| Inner dimension mm | 1000W×1000D×1000H | 1500W×1500D×1500H | 2000W×2000D×2000H|2500W×2500D×2000H | |
| TemperaturePerformanceParameters | ||||
| Temperature range℃ | -70~+150 | |||
| Heating rateC/min | 2(-40C→+85C) | |||
| Cooling rateC/min | 2(+85C→-40C) | |||
| Temperature fluctuation C | ±0.5 | |||
| Temperature deviation C | ±1 | |||
| Temperature uniformity C | ±2 | |||
| PressurePerformanceParameters | ||||
| Pressure range Pa | Normal pressure~500 | |||
| Depressurization time min | Normal pressure→1kPa≤45 | |||
| Pressure recovery kPa/min | ≤10 | |||
| Pressure deviation kPa | Normal pressure~25:±2/25~2:±0.5/2~0.4:±0.1 | |||
| Temperature-Humidity Climate Parameters (normal pressure,no load) | ||||
| Temperature rangeC | 20~85 | |||
| Humidity range %RH | 20~98 | |||
| Humidity deviation %RH | ≤75%RH:≤±5%/>75%RH:≤±3% | |||
| Dew point temperatureC | 6~81 | |||
| Test port mm | 2xISO-100,4×KF-50 4xISO-100,4×KF-50 | |||
| Viewing window mm | φ200 | |||
| Power supply | 3/N/PEAC,380V±10%,50Hz | |||
| Optional vibration shaker | DC-6500 | DC-6500_DC-10000 | DC-6500 DC-10000 DC-12000 | |
| DC-12000 | DC-16000 DC-20000 | |||
C
CTSSERIES
VehicleTestChamber
Thevehicle testchamberisalarge climate simulation chamberdesignedto testvehicles,large parts,and products againstvarious environmental conditions like extreme temperatures,humidity,temperature cycles,shocks,rapid changes,andolariationItisssetialinidustriesschasviationerospace,tomotiveomepld research.Thechamber mainlyconsistsofathermalinsulationcabin,airconditioning,freshairsystem,dynamometer exhaustemissionsystem,andsolarirradiationsystem,withcustomizablecomponents basedonrequirements.
It can be highly customized to meet all customer-specific requirements and needs.
Can offer comprehensive multichambercombinationandtailored customized solutions.
alternating high and low humidity environment
01 486m³ vehicle test chamber
02 500m² vehicle test chamber
03 780m² vehicle test chamber
04 100m² vehicle test chamber
Various air duct layoutscan be customizedto fitthecustomer'ssite.
回
Can provide various door types based oncustomerneeds,includingdouble doors,electric slidingdoors,electric upward sliding doors,etc.Multiple air duct layouts can also be customized to fit the customer's site.
C
KMTSERIES
Thermal Vacuum TestChamber
The thermal vacuum test chamber offers a vacuum level better than 1 0 ^ { 3 } Pa. It features an internal annular heat sink to simulate cold blackspaceandatemperature-controlledbotom plate to speedupspecimentemperature stabilization under high vacuum.The system monitors and records temperature data throughout the test.It is ideal for space environmentandreliability testingofmaterials,components,assemblies,parts,andsmaldevicesin theerospace industry.
| Type | 810 | 812 |
| Vessel dimensionmm | Φ1000×1000 | Φ1000×1200 |
| Heat sink mm | Φ800×1000 | Φ800×1200 |
| Specimeninstallationbase plateL×Wmm | 650×600 | 800×600 |
| Bottomplate installationpositionmm | 200±2 below the center line | 200±2 below the center line |
| Solarspectrum absorption coefficient of the inner surface of the heat sink | ||
| Hemispherical emissivity of the inner surface of the heat sink | ||
| Temperature performance parameter | ||
| Heat sink temperature rangeC | ||
| Installation base temperature range℃ | ||
| Average temperaturechange rateof heatsinkC/min | ||
| Average temperature change rate of bottom plateC/min | ||
| Heat sink temperature uniformityC | ||
| Bottom plate temperature uniformityC | ||
| Pressure performance parameter | ||
| UItimate pressure Pa | ||
| Working pressure Pa | ||
| Main pump pressure pumping time | ||
| Simulated loadkg | 10 | |
| Simulated load dimension WxD×H mm | 350×400×400 350×600×400 | |
| Main pump | ||
| Oil Pump | ||
| Backingpump | ||
| Refrigerationmethod | ||
| Power Requirements | ||
| Heating power kW | ||
| PowerkW | 50 55 | |
| Noise dB(A) | ||
| Condensation method | ||
| Total weight kg | 1950 | 2250 |
| 1010 | 1015 | 1216 | 1515 |
| Φ1200×1000 | Φ1300×1500 | Φ1500×1600 | Φ1800×1500 |
| Φ1000×1000 | Φ1000×1500 | Φ1200×1600 | Φ1500×1500 |
| 650×600 | 1200×600 | 1200×800 | 1300×1100 |
| 250±2 below the center line | 200±2below thecenter line | 300±2 below the center line | 300±2below thecenter line |
| αs≥0.93 | |||
| £H≥0.87 | |||
| -70~150 -70~150 | |||
| ≥2 | |||
| ≥2 | |||
| ±2 | |||
| ±2 | |||
| ≤5×10-5(Cryogenic pump+Molecular pump);≤5x10-4(Molecular pump) ≤1.3×10-3 | |||
| 5 | |||
| 15 | 20 | ||
| 350×600×400 | 300×300×400 | 450×850×500 | 450×850×500 |
| Cryogenic pump orMolecular pump | |||
| High and low temperaturemagnetic pump | |||
| Rotary vane pump+Roots pump | |||
| Mechanical cascade refrigeration (liquid nitrogen assisted refrigera tion) | |||
| AC380V50HzTN-S | |||
| 18 | 30 | 36 | |
| 60 | 60 | 75 | 96 |
| ≤75 | |||
| Water cooled | |||
| 2400 | 2800 | 3800 | 3800 |
SDK/SDL/SDE SERIES
Environmental Stress ScreeningChamber
Environmental Stress Screening (Ess)isareliabilitytest usedduring production to identifyandeliminate designor processdefectsandearlyfailures.Itcan beappliedatvarious productassemblylevels,suchasequipment,component and unit levels.
| SDKSeres eening | |||
| Temperature fluctuation | ±0.5°℃ | ||
| Temperature deviation | ±2°℃ | ||
| Temperature uniformity | ≤2°℃ | ||
| Humidity range | 20~98%RH(+20oC~+85C) Refer to the temperature and humidity range chart | ||
| Humidity deviation | ≤75%RH: ≤±5%;>75%RH: ≤+3% | ||
| Power supply | 3/N/PE AC,380V±10%,50Hz | ||
| Model | SDK402FH | SDK702FH | |
| Volume | 210L | 210L | |
| Test area dimension mm | 600W×500D×700H | 600W×500D×700H | |
| Overall dimension mm | 800W×1670D×1740H | 800W×1670D×1740H | |
| Load | No load | No load | |
| Temperature range | -40~+150℃ | -70~+150°℃ | |
| Heating and cooling rate | +20℃→+150C ≤60min;+20℃→-40C ≤90min | +20°℃→+150C ≤60min; +20C→-70C ≤75min | |
| Rated Power2kW | 6.5 | 8.5 | |
| Cooling method | Air-cooled | Air-cooled | |
| Model | SDK405FH | SDK705FH | |
| Volume | 500L | 500L | |
| Test area sdimension mm | 800W×700D×900H | 800W×700D×900H | |
| Overall dimension mm | 1000W×1540D×1950H | 1000W×1540D×1950H | |
| Load | No load | No load | |
| Temperature range | -40~+150℃ | -70~+150℃ | |
| Heating and cooling rate | +20°C→+150°C ≤60min;+20C→-40C ≤90min | +20°℃→+150C ≤60min; +20C→-70C ≤75min | |
| Rated Power²W | 9 | 9 | |
| Cooling method | Air-cooled | Air-cooled | |
| Model | SDK410FH | SDK710FH | |
| Volume | 1000L | 1000L | |
| Test area dimension mm | 1000W×1000D×1000H | 1000W×1000D×1000H | |
| Overall dimension mm | 1200W×1840D×2050H | 1200W×1840D×2050H | |
| Load | No load | No load | |
| Temperature range | -40~+150℃ | -70~+150℃ | |
| Heating and cooling rate | +20℃→+150C ≤60min;+20℃→-40C ≤90min | +20℃→+150C ≤60min;+20℃→-70C ≤75min | |
| Rated Power²kW | 13 | 13 | |
| Cooling method | Air-cooled | Air-cooled | |
| SDLSeriesEhvironm screeningCnamberParameter | ||
| Temperature fluctuation | ±0.5°℃ | |
| Temperature deviation | ±2°C | |
| Temperature uniformity | ≤2°℃ | |
| Humidity range | 20~98%RH(+20oC~+85C) Refer to the temperature and humidity range chart | |
| Humiditydeviation | ≤75%RH: ≤±5%; >75%RH: ≤3% | |
| Power supply | 3/N/PEAC,380V±10%,50Hz | |
| Model | SDL402FH | SDL702FH |
| Volume | 210L | 210L |
| Test area dimension mm | 600W×500D×700H | 600W×500D×700H |
| Overall dimension mm | 800W×1670D×1740H | 800W×1670D×1740H |
| Load | No load | No load |
| Temperature range | -45~+150℃ | -70~+150°℃ |
| Heating and cooling rate | +20℃→+150°C ≤60min;+20℃→-40℃ ≤60min | +20C→+150C ≤60min; +20C→-70C ≤75min |
| Rated Power²kW | 5.5 | 7.5 |
| Cooling method | Air-cooled | Air-cooled |
| Model | SDL405FH SDL705FH | |
| Volume | 500L | 500L |
| Test area sdimension mm | 800W×700D×900H | 800W×700D×900H |
| Overall dimension mm | 1000W×1540D×1950H | 1000W×1540D×1950H |
| Load | No load | No load |
| Temperature range | -45~+150℃ | -70~+150℃ |
| Heating and cooling rate | +20℃→+150C ≤60min; +20℃→-40C ≤60min | +20C→+150C ≤60min; +20C→-70C ≤75min |
| Rated Power²kW | 8 | 9.5 |
| Cooling method | Air-cooled | Air-cooled |
| Model | SDL410FH | SDL710FH |
| Volume | 1000L | 1000L |
| Test area dimension mm | 1000W×1000D×1000H | 1000W×1000D×1000H |
| Overall dlimension mm | 1200W×1840D×2050H | 1200W×1840D×2050H |
| Load | No load | No load |
| Temperature range | -45~+150℃ | -70~+150℃ |
| Heating and cooling rate | +20℃→+150℃ ≤60min;+20°C→-40℃ ≤60min | +20°℃→+150℃ ≤60min;+20℃→-70℃ ≤75min |
| Rated Power²kW | 11 | 13 |
| Cooling method | Air-cooled | Air-cooled |
| SDESeresHi rormanc | |||||||
| Temperature fluctuation | |||||||
| Temperature deviation | ±2°℃ | ||||||
| Temperature uniformity | ≤2°℃ | ||||||
| Humidity range | 20~98%RH(20~+85C)Refer to humidity range chart | ||||||
| Humidity deviation | |||||||
| Power supply | |||||||
| Model | SDE702SH-A SDE702SH-B SDE702SH-C | ||||||
| Volume | 210L | ||||||
| Test area dimension mm | 600W×500D×700H | ||||||
| Overall dimensions mm | 20kg | 800W×2330D×2090H | |||||
| Load | 40kg | 20kg aluminum ingot | 10kg | ||||
| aluminum ingot aluminum ingot | -70~+150°℃ | aluminum ingot | |||||
| Temperature range Average | Average | 5 5 | 10 | ||||
| temperature change rate | Linear | 3 | 3 | 5 | 15 | ||
| C/min (-55℃~+85℃) | 10 | ||||||
| Rated powerkW | 12.5 3 | 15.5 | 25.5 | 30 | |||
| Cooling circulatingwater flow t/h | 400 | 4.5 500 | 8.5 600 | 10 | |||
| Weight kg | SDE705SH-A | SDE705SH-B | SDE705SH-C | 650 SDE705SH-D | |||
| Model | SDE705SH-E | ||||||
| Volume | 500L | ||||||
| Test area dimension mm Overall dimension mm | 800W×700D×900H 1000W×2570D×2310H | ||||||
| Load | 20kg 40kg | ||||||
| Temperaturerange | aluminum ingot | aluminum ingot | aluminum ingot -70~+150°℃ | aluminum ingot | aluminum ingot | ||
| Average | Average | 5 | 5 | 10 | 15 | 15 | |
| temperaturechange rate | Linear | 3 | 3 | 10 | |||
| C/min (-55℃~+85℃) | 5 | 10 | |||||
| Rated power kW | 16 | 21 | 30.5 | 41 | 48.5 | ||
| Cooling circulating water flow t/h | 4.5 1100 | 6.5 1200 | 10 1400 | 13 | 16.5 | ||
| Weight kg | SDE710SH-B | SDE710SH-C | 1600 SDE710SH-D | 1700 SDE710SH-F | |||
| Model | SDE710SH-A | ||||||
| Volume | 1000L 1000W×1000D×1000H | ||||||
| Test area dimension mm | |||||||
| Overall dimensions mm | 1200W×3100D×2470H 20kg | 40kg. | 1200W×3100D×2470H | ||||
| Load | aluminum ingot | aluminum ingot 50kg | aluminum ingot | aluminum ingot | aluminum ingot | ||
| Temperature range | -70~+150°℃ | -70~+150°℃ | |||||
| Average | Average | 5 | 5 | 10 | 10 | 15 | |
| temperature change rate | Linear | 3 | 3 | 5 | 5 | 10 | |
| C/min (-55C~+85℃) Rated power kW | 22 | 31 | 42 | 60 | 72 | ||
| Cooling circulatingwater flow t/h | 6.5 | 10 | 13 | 18 | 24 | ||
| Weight kg | 1600 | 1700 | 1800 | 1900 | 2100 | ||
| SDE720SH-A | |||||||
| Model Volume | SDE720SH-C SDE720SH-D 2000L | ||||||
| 2000L 1200W×1400D×1200H | 1200Wx1400D×1200H | ||||||
| Testarea dimensionmm Overall dimension mm | 1500W×3500D×2630H | 1500W×3500D×2630H | |||||
| Load | 80kg | 40kg | 120kg | 80kg | |||
| Temperature range | aluminum ingot aluminum ingot -70~+150℃ | aluminum ingot aluminumingot -70~+150°℃ | |||||
| Average | Average | 5 | 5 | 10 | 10 | 15 | |
| temperature change rate | Linear | 3 | 3 | 5 | 5 | 10 | |
| C/min (-55C~+85℃) | |||||||
| Rated power kW Cooling circulating water flow t/h | 31.5 | 42 | 60 | 73 24 | 92 | ||
| 10 | 13 | 20 | 31 | ||||
| Weight kg | 1900 | 2000 | 2200 | 2400 | 2400 | ||
C
SDPSERIES
High and Low Temperature and Low Pressure Test Chamber
High and lowtemperatureand low pressure testchambers simulate temperature,altitude,and humidityconditions. Theyareusedforenvironmentalandreliabilitytestingof materials,components,assemblies,parts,instruments,and smallequipmntitiorospaeomie,igrmtioologydletroics.
| SDPSeries Highand Lowtemperatureand LowPressureTest ChamberTechnicalParameter | |||||||||
| Model | 702S 702SH | 705S | 705SH | 710S | 710SH | 720S | 720SH | ||
| Volume L | 210 | 504 | 1000 | 2016 | |||||
| Cabinet depth mm | 500 | 700 | 1000 | 1200 | |||||
| Cabinet width mm | 600 | 800 | 1000 | 1200 | |||||
| Cabinet height mm | 700 | 900 | 1000 | 1400 | |||||
| Depth mm | 2660 | 2865 | 3415 | 3615 | |||||
| Width mm | 1000 | 1200 | 1400 | 1600 | |||||
| Height mm | 1620 | 1950 | 2380 | 2680 | |||||
| Temperatureperformance parameter | |||||||||
| Temperature rangeC | -70~150 | ||||||||
| Heating time min | 20C→150C≤90min | ||||||||
| Cooling time min | 20C→-70C≤90min | ||||||||
| Heating and cooling rateC/min | 1C/min (-55~+85C,linear) | ||||||||
| Load (aluminum ingot) kg | 20 | 25 | 25 15 | 100 24 | |||||
| Heating power W | 6 12 | ||||||||
| Temperature fluctuationC | ≤1 | ||||||||
| Temperature uniformityC | ≤2 | ||||||||
| Temperature deviation C | ±2 | ||||||||
| Pressureperformanceparameter | |||||||||
| Ultimate pressure kPa | 1 | ||||||||
| Depressurization time min | Normal pressure→1kPas45min | ||||||||
| Pressure recovery kPa/min Pressure deviation | ≤10 Normal pressure~40kPa:≤±2kPa;4kPa~40kPa:≤±5%kPa; below 4kPa:≤±0.1kPa | ||||||||
| Temperatureand humidity climate parameter | |||||||||
| Temperature rangeC 20~85 | |||||||||
| Humidity range %RH | |||||||||
| Humidity deviation %RH | 20~98 ±3%RH (humidity>75%RH) | ||||||||
| ±5%RH (humidity≤75%RH) | |||||||||
| Humidification power kW Vacuum pump kW | 4.5 | 9 | 1.1 | ||||||
| Power Requirements | 0.55 | 0.9 AC380V 50Hz three-phase five-wire | |||||||
| Maximum current A | 47 47 61 | 65 | 65 | 104 | 104 | ||||
| Total power kW | 22 22 | 25 | 25 | 61 | 34 | 34 | 54 | 54 | |
| Noise dB(A) | ≤75 10 | 15 | |||||||
| Cooling water m³/h | 7 | ||||||||
| Condensation method | 1400 | Water cooled 1500 | |||||||
| Total weight kg | 950 1050 | 1800 | 1900 | 2600 | 2800 | ||||
Note:
C
TSMSERIES
Thermal Shock Chamber (Two-zone Shock)
TSM series thermal shock chambers simulate rapid temperature changes between high and low temperature zones forenvironmentalsimulation,reliabilitytesting,andstress screeningofelectronicproducts,components,parts,nd materials.Specimens are moved between two test spaces via a basket to create thermal shock.
Note:
| TSMSeries Thermal Shock Chamber (Two-zone Shock) Technical Parameter | ||||||||||||||
| Model | 401FL 402SL 403SL 405SL 410SW 501SL 502SL 503SL 505SL 510SW 601SL 602SL | 603SL 605SL | ||||||||||||
| Volume L | 27 | 64 | 125 | 210 | 512 | 27 | 64 | 125 | 210 | 512 | 27 | 64 125 | 210 | |
| Basket depth mm | 300 | 400 | 500 | 650 | 800 | 300 | 400 | 500 | 650 | 800 | 300 | 400 | 500 | 650 |
| Basket width mm | 300 | 400 | 500 | 650 | 800 | 300 | 400 | 500 | 650 | 800 | 300 | 400 | 500 | 650 |
| Basket height mm | 300 | 400 | 500 | 500 | 800 | 300 | 400 | 500 | 500 | 800 | 300 | 400 | 500 | 500 |
| Depth mm | 1970 | 1830 | 2110 | 2570 | 1810 | 1970 | 1830 | 2110 | 2570 | 1810 | 1970 | 1830 | 2110 | 2570 |
| Width mm | 1340 | 1560 | 1530 | 1720 | 3110 | 1340 | 1560 | 1530 | 1720 | 3110 | 1340 | 1560 | 1530 | 1720 |
| Overall height mm | 2000 | 2250 | 2360 | 2610 | 2550 | 2000 | 2250 | 2360 | 2610 | 2550 | 2000 | 2250 | 2360 | 2610 |
| Chamber structure | Vertical | Horizontal | Vertical | Horizontal | Vertical | |||||||||
| Temperatureperformanceparameter | ||||||||||||||
| High temperature chamber temperature | ||||||||||||||
| range℃ Low temperature chambeature | -70~-0 | -80~-0 | ||||||||||||
| range℃ Shock | -55~150 | |||||||||||||
| temperature℃ | -40~150 | |||||||||||||
| Conversion time | 15 | |||||||||||||
| Recovery time min High temperature | 5 | |||||||||||||
| chamber heating time min Low temperature | RT→200°C≤60min | RT→-70°C≤60min | ||||||||||||
| chamber cooling time min ingot (aluminum | 5 | RT→-55C≤60min 20 | 40 | 5 | RT→-65C≤60min | |||||||||
| Temtuaraturec | 10 | 15 | 10 | 15 ≤1 | 20 | 40 | 5 | 10 | 15 | 20 | ||||
| Teimprmityre | ||||||||||||||
| Teviatirnture | ±2 | |||||||||||||
| Power Requirements | ||||||||||||||
| Power kW | 18 | 21 26 | 35 | 51 | AC380V 50Hz three-phase five-wire 18 | 24 | 27 | 45 | 83 | 24 | 34 | 36 | 60 | |
| Noise dB(A) | ≤75 | |||||||||||||
| Condensation | Air Water | |||||||||||||
| method Total weight kg | cooled 800 | 900 | 1100 | 1200 | 1300 | 800 | 1200 | cooled 1300 | 1350 | 1450 | 920 | 1200 | 1300 | 1500 |
C
TSDSERIES
Thermal Shock Chamber (Three-zone Shock)
TSDseries thermal shock testchambersare usedforenvironmentalsimulation,reliabilitytestingandstress screening of electronicomponents,products,ssemblies,andmaterials.Theyprovideafixedtestspaceforrapid temperature changes within specified limits.Unliketransfer-type chambers,TSDchambers keep specimensstationaryand create thermal shock by switching air doors,preventing damage to sensitive or small parts during movement.
| 401FL 402SL404SW405SW410SW 502SL 503SW 504SW 505SW 510SW 603SW605SW | ||||||||||||
| Model Volume L | 80 | 150 | 364 | 504 | 1000 | 150 | 252 | 364 | 504 1000 | 252 | 504 | |
| Cabinet depth mm | 400 | 500 | 700 | 800 | 1000 | 500 | 600 | 700 | 800 | 1000 | 600 | 800 |
| Cabinet width mm | 500 | 600 | 800 | 900 | 1000 | 600 | 700 | 800 | 900 | 1000 | 700 | 900 |
| Cabinet height mm | 400 | 500 | 650 | 700 | 1000 | 500 | 600 | 650 | 700 | 1000 | 600 | 700 |
| Depth mm | 1760 | 2020 | 2400 | 2560 | 3400 | 2020 | 2200 | 2400 | 2560 | 3400 | 2400 | 2560 |
| Width mm | 1500 | 1600 | 1850 | 2050 | 2150 | 1600 | 1850 | 1850 | 2050 | 2150 | 1850 | 2050 |
| Overall height mm | 2150 | 2300 | 1820 | 2000 | 2320 | 2300 | 1770 | 1820 | 2000 | 2320 | 1770 | 2000 |
| Chamber structure | Vertical | Horizontal | Vertical | Horizontal | ||||||||
| Temperatureperformanceparameter | ||||||||||||
| Himghtemturature chamber 60~200 | ||||||||||||
| Lewptermturaturechamber | -70~0 | |||||||||||
| Working room temperature | -70~200 -75~200 | |||||||||||
| Temperature shock rangeC | -40~150 -55~150 -65~150 | |||||||||||
| Conversion time | 15 | |||||||||||
| Recovery time min | 5 | |||||||||||
| Highitemimeraturechamber | RT→200C≤60min | |||||||||||
| Low temperature chamber cooling time min | RT→ RT→ | |||||||||||
| Load (aluminum ingot) kg | 5 10 | 20 | -55C≤60min 25 | 50 | 10 | -65℃≤60min 15 | 20 | 25 50 | 10 | -70C≤60min 10 | ||
| Temperature fluctuation C | ≤1 | |||||||||||
| ≤2 | ||||||||||||
| Temperature uniformityC | ||||||||||||
| Temperature deviation C | ±2 | |||||||||||
| Power Requirements | AC380V 50Hz three-phase five-wire | |||||||||||
| Power kW | 25 | 25 61 70 | 76 | 115 | 42 50 | 67 | 87 | 142 | 64 | 93 | ||
| Noise dB(A) | 70 | 74 | 75 | 76 | 73 | 74 | 75 | 76 | 77 | 76 | 76 | |
| Condensation method | ciled | Wated | ||||||||||
| Total weight kg | 1200 1700 | 2200 | 2400 | 2500 1800 | 2150 | 2300 | 2450 | 2600 | 2250 | 2450 | ||
Note:
WG/DGT/DGF/CS SERIES
Heating& Dryingchamber
| Model | 2001 | 2002 | 2005 | 2010 | 3001 | 3002 | 3005 | 3010 | |
| Volume L | 101 | 165 | 510 | 1000 | 101 | 165 | 510 | 1000 | |
| Cabinet Depth mm | 450 | 550 | 850 | 1000 | 450 | 550 | 850 | 1000 | |
| Cabinet width mm | 450 | 500 | 750 | 1000 | 450 | 500 | 750 | 1000 | |
| Cabinet High mm | 500 | 600 | 800 | 1000 | 500 | 600 | 800 | 1000 | |
| Depth mm | 690 | 770 | 1070 | 1220 | 690 | 770 | 1070 | 1250 | |
| Width mm | 1070 | 1120 | 1390 | 1640 | 1070 | 1120 | 1390 | 1660 | |
| Height mm | 820 | 920 | 1120 | 1320 | 820 | 920 | 1120 | 1320 | |
| Temperature performance parameter | |||||||||
| Maximum temperatureC | 200 | 300 | |||||||
| Minimum temperature C | Room temperature +10 | ||||||||
| Heating rate min | Room temperature→200C≤45min | Room temperature→300oC≤90min | |||||||
| Linear heating rateC/min | 1 | 1 | 1 | 1 | 1 | 1 | 1 | 1 | |
| Temperature fluctuation C | ≤1 | ≤1 | |||||||
| Temperature uniformity C | ≤2 | ≤2within 200°C;≤4above 200C | |||||||
| Temperature deviation ℃ | ±2 | ±2within 200C;±4above 200℃ | |||||||
| Controller | Adopt Japan FujiPXF9 temperature controler,digitaldisplay control,with PID self-tuning function, | can switch between fixed value and ramp control | |||||||
| Power requirements AC | AC220V | AC380V | AC220V | AC380V | |||||
| Total power kW | 3 | 4.5 | 7 | 10 | 3 | 4.5 | 7 | 10 | |
| Noise dB(A) | 68 | ||||||||
| Total weight kg | 70 | 80 | 100 | 180 | 75 85 | 105 | 185 | ||
WG/DGT/DGF/CS SERIES
| GT\DGF\CSSerlesDryingChamberTechnicalParameter | ||||
| DGT DGT DGT | ||||
| Model | 2006B | 202B | 302B | |
| Volume L | 640 | 2460 | 2460 | |
| Cabinet depth mm | 800 | 1100 | 1100 | |
| Cabinet width mm | 800 | 1500 | 1500 | |
| Cabinet high mm | 1000 | 1600 | 1600 | |
| Depth mm | 1070 | 1440 | 1440 | |
| Width mm | 1300 | 2270 | 2270 | |
| Height mm | 1280 | 1920 | 1920 | |
| Temperature performance parameter | ||||
| Maximum temperatureC | 200 | 200 | 300 | |
| Minimum temperatureC | Room temperature +20 | |||
| Heating time min | Room temperature → 200°℃≤60min | Room temperature→ 300°C≤90min | ||
| Temperature fluctuation C | ≤±0.5 | |||
| Temperature uniformity C | ≤±2.5% | |||
| Controller | AdoptShanghai Yatai YL30o0 series | |||
| Heater type | Nickel-chromium heating tube | |||
| Power requirements AC | 380V/50Hz three-phase five-wire system | |||
| Total power kW | 7.5 | 16 | 16 | |
| Noise dB(A) | 68 | 68 | 68 | |
| Total weight kg | 200 | 500 | 500 | |
| DGF 3006B | DGF 4002B | CS 1EB | CS 2EB | CS 3EB |
| 640 | 225 | 72 | 137 | 234 |
| 800 | 500 | 400 | 500 | 600 |
| 800 | 600 | 450 | 550 | 650 |
| 1000 | 750 | 400 | 500 | 600 |
| 1070 | 880 | 580 | 680 | 780 |
| 1320 | 1230 | 610 | 710 | 810 |
| 1280 | 1080 | 910 | 1030 | 1180 |
| 300 | 400 | 300 | ||
| Room temperature +20 | Room temperature +20 | |||
| Room temperature → 300℃≤90min | Room temperature→ 400°C≤100min | Room temperature→ 300°℃≤90min | ||
| ≤±0.5 ≤±2.5% | ≤±0.5 | |||
| temperature controller,Digital temperature control with PID self-tuning function | ≤±2.5% | |||
| Nickel-chromium heatingwire | Nickel-chromium heatingwire | |||
| 380V/50Hz | 220V | 220V | ||
| 5.5 | 7 | 1.8 | 2.7 | 3.6 |
| 68 200 | 68 600 | 68 50 | 68 70 | 68 90 |
PRODUCT DISPLAY
ProviderofEnvironmental
Test Equipment Solutions
41|SST
DEVELOPMENT BASE
Suzhou Development Base
Mechanical,Climatic&Combined Environmetal TestSystemDevelopmentBase
No.55,uhan d,ewistrict,uhou,Jiangsu,ina
Chongqing Development Base
Climatic Environmental Test System Development Base
No.8, Huijin Rd,North New District, Chongqing, China No.3,Tiankang Rd, Yubei District, Chongqing, China
Yangzhou Development Base
Analytical&TestSystemand Sensor Development Base
No. 47, Xiangyun Rd, Hanjiang District, Yangzhou,Jiangsu, China
Headquarter Address BranchAddress
No.5l,Fangyuan St, Industrial Park, Suzhou No.55,Lushan Rd,New District,Suzhou




