MACON
SUPERHEATPLUS R290
NEWECOHOMESSOLUTION
Heating Cooling and Domestic Hot Water
MACON
PRODUCTFEATURES
Heating,CoolingandDomesticHotWaterfor MultifunctionApplications
MACON SuperHeat Plus Series is an integrated all-in-one system that meets all needs in your home including space heating, cooling, and domestic hot water. It is an ideal alternativefor traditional gas orfuel oil heating thatprovidesyou delightful warm and perfect hotwater supply throughout the year.
Heating in winter
MACON SuperHeatPlus Series can stably keeps heating in whole house during coldseasonstoimproveyourcomfort.
Cooling in summer
MACON SuperHeat Plus Series can quickly cools down andmaintains comfortablecooling duringhot seasons.
Domestichot water all year round Securing all yourhotwater demands throughout theyear includes bathing and washing in the whole house.
HIGHWATERTEMPERATURE
MaximumWaterTemperature \mathbf{75°C}, Meets theDemandsforMulti-pointWater Usage
MACON SuperHeat Plus Series can be installed with underfloor heating system, fan coil units, radiators, and domestic hot water tanks. With high temperature up to 75°{\mathsf{C}}, it is able to maintain optimal temperature and a continuous supply of hot waterthroughouttheyear, evenwith anoldcast ironradiators.
R290REFRIGERANT
MOREENVIRONMENTALFRIENDLY
Inordertoachievecarbonneutralityandmitigateglobal warming,MACONSuperHeatPlusSeriesusestheR290 naturalrefrigerant,whichhasasmallerimpactonglobal warming compared toother synthetic alternatives andis harmlessto theozonelayer.ThisenablesMACONSuperHeat PlusSeriestoprovidemoresustainable,green,and comfortablehotwaterheatingandcoolingsolutions.
Natural, Non-toxic and Ozone-free
R290 is a high-purity propane refrigerant with a global warming potential(GWP)of 3,which means itwill nothaveasmuch impact onozonedepletion asotheroptions.Itcomplieswith the environmental regulationsinmultiplecountries,makingit an environmentalfriendlychoice.
Excellent Thermodynamic Performance
R290 refrigerant iswith excellent thermodynamic performance,whichis abletomakehigherwater temperaturestomeetvariousapplication demands.
HIGHEFFICIENCY
DoubleA+++Energy Efficiency Class
MACON SuperHeat Plus Series achieves the best performance up to _{\mathsf{A}+++} energy rating forboth conditions underA7W35 and A7W55 according toERPDirective.
Technologies for Energy-Saving Performance
The technologically advanced MACON SuperHeat Plus Series takes a step ahead in terms of efficiency and sustainability.
Full Inverter Technology
The uses of DCinvertercompressor,DCfan motor andDCinvertercontroller contribute to significant improvement on the energy-saving effect by 15%
Enhanced Vapor Injection Technology
Thanks to the EVI technology, the heating efficiency is increased by more than 10% incoldclimate.
SMARTTOUCHDISPLAY
MACONSuperHeatPlushasahigh-endcontrollerwithcolorfultouch screen,whichisoneof thehighlightsof thistrendyheatpumpproduct. Itisincrediblyconvenientforusersfromdifferentcountriesthat multiplelanguagescanbechosen.
SmartAPPcontrolbringsalotofconveniencetousers.Temperature adjustment,modeswitching,andtimersettingcanbeachievedonyour smartphoneanytimeandanywhere.
MACON SMART CONTROL FAMILY
GUARANTEEDPERFORMANCES: HIGHHEATINGCAPACITIESDOWNTOLOWOUTSIDE TEMPERATURE
MACON SuperHeatPlus maintainsitshigh heating capacities down to low outdoor temperatures.The electrical back-up heater assistance is no longer required or only very limited. These high heating capacities, available on the whole MAcON SuperHeatPlus8kW-40kWrange,are achieved thanksto the combinationof:
·Optimized controls to achieve higher frequency of use at low
outdoortemperatures
·Liquid injection to avoid too high discharge temperatures
when high water temperatures are required at low outdoor tem
peratures
·Perfectly dimensionedplate heat exchangers to maximize theheat exchange surface
WideWorking Ambient Temperature Range
Wideworkingambienttemperature range: -30°C~48°C .Intelligentcontrol withautomaticloadadjustmentdesignto ensurereliableoperationunderdifferent climates.
High Outlet Temperature
Themaximumleavingwatertemperature is 75\circ C withoutbackupheaterdownto -25% outdoortemperature.
MINIMUMENERGYCONSUMPTION: MACONSUPERHEATPLUSINVERTER COMPRESSORSWITHHIGHMODULATINGRANGE
Whentheheatloadislowerthanthemaximumcapacityoftheheat pumpsystem,thecompressorcanturn inpartial loadoperation.This reduced compressorfrequencyresultsin:
·Higher compressor efficiency in partial load operation ·Delivered capacities exactly matching the actual heating demand of thebuilding ·Obtaining the capacities needed with minimum energy consumption ·Lesson/offoperation,increasingtheoperation lifecycleofthe compressor as MACON SuperHeat Plus has a high modulating range, meaning thecompressorcanmodulatedown tolowfrequenciesto offer the highest efficiencies over the relevant temperature range.
Each inverter compressor has a certain maximum and minimumfrequency, andworks in between the optimal operation area with the highest operating efficiencies. This isillustrated by the graph bellow.
Accelerated Heating
Aftertheunitisstarted,itquicklyentersa stableandefficientoperatingstate.MACON SuperHeatPlushasmoreheatingoutputthan ordinaryheatpumpinthesameworkingtime.
Intelligent Defrosting
MACONSuperHeatPlusisdesignedwithhigh performanceadaptiveintelligentdefrost technologythatcanadjusttheheatpump operationautomaticallyaccordingtotheactual runningstatus,reducing 40% ofineffective defrosttimecomparedtotraditionalheatpumps.
SMARTHEATINGCONTROL
ThecombinedeffectoftheMACONSuperHeatPlusweather-dependentset-pointcontrol andtheinvertercompressorsmaximizes the efficiency at each outdoor temperature,assuring stable roomtemperatures.
1Weather-dependentset-pointcontrol:MAcONSuperHeatPlus maximizes efficiency at everyoutdoor temperature through its weather-dependent set-point control. This control logic will alwayskeepthewatertemperaturesaslowaspossible,tomaximizetheheatpumpefficiencyforeachspecificoutdoor temperature.Thisresults in:
·Higherheatpumpefficiencywithlowerwatertemperatures
·Nounnecessary overheating,thereby delivering the temperaturesrequired
·Continuous heating at lower water temperatures,providing stable room temperatures
2Inverter technology:lowering thecompressor frequency with increasing outdoor temperatures, thus
increasingtheefficiency
Threemodes
Threeheatingmodes including energysaving mode,fastheatingmodeandquietheating modeareavailabletomeetthedemandsof usersunderdifferentconditions.
Control thewater temperatureinmultiple timeperiods
Automaticregulationofwatertemperature accordingtothesettingtimephases.Automaticwaterchangingtimerthatcanallow userstosetuptofourtimersofchangingthe watertemperatureduringaday.
STABLE&RELIABLE
Outstanding Performance in All Conditions
MACON SuperHeat Plus Series can efficiently provide house heating, cooling and domestic hot water even under extremely cold weather conditions, so it can be used in most regions of Europe.
High-quality Compressor
Panasoniccompressorensuresstableandreliable performanceforidealhomecomfort.
EVI (Enhanced Vapor Injection)
With EVItechnology,theheatingperformance isstillexcellentin coldweatherconditions.
·No attenuation in heating performance even at -10°\mathsf{C} ·Supply 75\circ C hotwateratoutdoortemperaturedownto -25∞ c ·Stableoperation in coldweatherconditionsdownto -30°C
MULTIPLEANTI-FREEZEPROTECTION
By implementingmultiple anti-freezing technologiessuch aswater pump circulation,system circulation,and chassisheating,the temperature of theheatpump andpipelinesare automatically monitored.Whentheambienttemperatureisbelow 2°C andthewatertemperatureisbelow 7°\mathsf{C}, the heatpumpwill automaticallyheatupto 15°\mathsf{C}, whichcanworktopreventthesystemfromfreezing.
Water pump circulation
When the ambient temperaturegetsdown tothe anti-freezing temperature,the circulating water pumpstartsrunning.
System circulation
The heat pump and pipelines temperatures are automaticallymonitored topreventsystemfrom freezing.
Chassis heating
Optimize the evaporator drain path,heat the chassistopreventfrostingatthebottom
SMARTDEFROST
By monitoring the operating temperature through several sensors and the defrosting time,MAcoN SuperHeatPlusSeriesperforms smart defrost according to actual demand toprevent invalid operation,which makes itmore effective and energy-saving compared with scheduled defrost.
AISMARTDEFROSTMODULE
EASYINSTALLATION
MACON hydraulic integrated indoor unit is builtwithspecialregardforthespaceand area it takes inside the house,as well as the aestheticvisual impact it causes.Upgrading yourhousewhilegivingthecomfortthat youneed.
Installation Diagram
MACON hydraulic integrated indoor unit 150L,200L and300L aretheideal solutionsfor various construction projects, meeting heating & cooling and domestic hot water (DHW) needs.
POWERFUL&MONEYSAVINGS
Combinablewith OtherHeatSources
MACON SuperHeat Plus can also be combined with various heat sources such as solar collectors, gas furnaces, and boilers, providing the highest efficiency and lowest cost operation.
| Model | KRCHRW | 08ZA-PBEN2A | 10ZA-PBEN2A | 12ZA-PBEN2A | 14ZA-PBEN2A | 16ZA-PBEN2A | |
| Intendeduseoftheunits | Lowandmediumtemperatureapplication | ||||||
| Powersupply | V/Ph/Hz | 220-240/1/50 | |||||
| Heating (AT7/6,WT30/35) | Capacity | kW | 8 | 10 | 12 | 14 | 16 |
| Ratedpowerinput | kW | 1.62 | 2.08 | 2.45 | 2.74 | 3.25 | |
| COP | kW/kW | 4.95 | 4.8 | 4.9 | 5.11 | 4.92 | |
| Heating (AT7/6,WT47/55) | Capacity | kW | 8 | 10 | 12 | 14 | 16 |
| Ratedpowerinput | kW | 2.42 | 3.03 | 3.43 | 4.24 | 5.00 | |
| COP | kW/kW | 3.3 | 3.3 | 3.5 | 3.3 | 3.2 | |
| Cooling (AT35,WT23/18) | Capacity | kW | 8 | 10 | 11.4 | 14 | 16 |
| Ratedpowerinput | kW | 1.63 | 2.15 | 2.78 | 2.74 | 3.33 | |
| COP | kW/kW | 4.9 | 4.65 | 4.1 | 5.11 | 4.8 | |
| Cooling (AT35,WT12/7) | Capacity | kW | 8 | 10 | 11.4 | 14 | 16 |
| Rated powerinput | kW | 2.50 | 3.33 | 4.07 | 4.52 | 5.52 | |
| COP | kW/kW | 3.2 | 3 | 2.8 | 3.1 | 2.9 | |
| SCOP | Averageclimate | 35℃ | 4.9 | 4.9 | 4.9 | 5.2 | 4.9 |
| Averageclimate | 55℃ | 3.85 | 3.85 | 3.85 | 3.9 | 3.9 | |
| Season space heatingenergy efficiency class | Averageclimate | 35°℃ | A+++ | A+++ | A+++ | A+++ | A+++ |
| Averageclimate | 55℃ | A+++ | A+++ | A+++ | A+++ | A+++ | |
| SEER | Fan coilapplication | 7℃ | 4.5 | 4.5 | 4.5 | 5.1 | 5.1 |
| Coolingfloorapplication | 18℃ | 6.3 | 6.5 | 6.2 | 7 | 7 | |
| Refrigerant | Type | R290 | |||||
| Charge | kg | 1.3 | 1.3 | 1.35 | 1.95 | ||
| Sound Level | dB(A) | 52 | 53 | 55 | 56 | 1.95 | |
| Waterpump | Ratedwaterflow | 56 | |||||
| m3/h | 1.38 | 1.72 | 2.06 | 2.41 | 2.75 | ||
| Total waterhead | m | 12.5 | 12.3 | 12 | 11.5 | 11.1 | |
| Maximumworkingpressureofrefrigerant | Availablewaterhead | m Mpa | 9 | 8.8 | 8.5 | 8 | 7.6 |
| Watersidesafetyvalve | Mpa | 0.85/3.2 | |||||
| / | 0.6 | 0.6 | 0.6 | 0.6 | 0.6 | ||
| Waterproofgrade | IPX4 | ||||||
| Waterside connection | in | 1 | 1 | 1 | 1 | 1 | |
| Netdimension Packagedimension | W*D*H | mm | 1170/440/880 | 1170/440/880 | 1170/440/880 | 1215/500/1395 | 1215/500/1395 |
| Ambienttemperaturerange | W'D*H | mm | 1270/480/1035 | 1270/480/1035 | 1270/480/1035 | 1315/540/1550 | 1315/540/1550 |
| Cooling | ℃ | 10-48 | |||||
| Heating | ℃ | -30-35 | |||||
| Leavingwatertemperaturerange | Domestichotwater | °℃ | -30-43 | ||||
| Cooling | °℃ | 5-25 | |||||
| Heating | °℃ | 24-60 | |||||
| Domestichotwater | ℃ | 30-75 | |||||
| Model | KRCHRW | 20ZA-SBEN2A | 24ZA-SBEN2A | 28ZB-SBEN2A | 32ZB-SBEN2A | 50ZB-SBEN2A | |
| Intendeduseoftheunits | Low andmediumtemperature application | ||||||
| Powersupply | V/Ph/Hz | 380/3/50 | |||||
| Heating (AT7/6,WT30/35) | Capacity | kW | 20 | 24 | 28 | 32 | 50 |
| Ratedpowerinput | kW | 4.17 | 4.90 | 5.48 | 6.50 | 9.75 | |
| COP | kW/kW | 4.8 | 4.9 | 5.11 | 4.92 | 5.13 | |
| Heating (AT7/6,WT47/55) | Capacity | kW | 20 | 24 | 28 | 32 | 50 |
| Rated powerinput | kW | 6.06 | 6.86 | 8.48 | 10.00 | 15.15 | |
| COP | kW/kW | 3.3 | 3.5 | 3.3 | 3.2 | 3.3 | |
| Cooling (AT35,WT23/18) | Capacity | kW | 20 | 22.8 | 28 | 32 | 50 |
| Ratedpowerinput | kW | 4.30 | 5.56 | 5.48 | 6.67 | 9.80 | |
| COP | kW/kW | 4.65 | 4.1 | 5.11 | 4.8 | 5.1 | |
| Cooling (AT35,WT12/7) | Capacity | kW | 20 | 22.8 | 28 | 32 | 50 |
| Rated powerinput | kW | 6.67 | 8.14 | 9.03 | 11.03 | 16.13 | |
| COP | kW/kW | 3 | 2.8 | 3.1 | 2.9 | 3.1 | |
| SCOP | Averageclimate | 35℃ | 4.90 | 4.90 | 5.20 | 4.90 | 5.00 |
| Averageclimate | 55℃ | 3.85 | 3.85 | 3.90 | 3.90 | 3.90 | |
| Seasonspaceheatingenergy efficiency class | Averageclimate | 35℃ | A+++ | A+++ | / | ||
| Averageclimate | 55°℃ | A+++ | A+++ | / | |||
| SEER | Fan coilapplication | 7°℃ | 4.5 | 4.5 | 5.1 | 5 | 5.1 |
| Cooling floorapplication | 18℃ | 6.5 | 6.2 | 7 | 7 | 7 | |
| Refigerant | Type | R290 | |||||
| Charge | kg | 2.6 | 2.7 | 3.9 | 3.9 | 3*2 | |
| Sound Level | ()aP) | 57 | 59 | 59 | 60 | 65 | |
| Waterpump | Ratedwaterflow | m3/h | 3.44 | 4.13 | 4.82 | 5.50 | |
| Total waterhead | 8.60 | ||||||
| Availablewaterhead | m m | / | / | ||||
| Maximumworkingpressureofrefrigerant | Mpa | / | |||||
| Watersidesafetyvalve | Mpa | 0.6 | 0.6 | 0.85/3.2 | |||
| Waterproofgrade | / | 0.6 IPX4 | 0.6 | 0.6 | |||
| Water side connection | in | 1-1/4 | 1-1/4 | 1-1/4 | 1-1/4 | ||
| Netdimension | W*D*H | mm | 1270/515/1600 | 1645/805/1580 | 2-1/2 | ||
| Package dimension | W*D'H | mm | 1270/515/1600 | 1645/805/1580 | 1750/875/1815 | ||
| 1370/545/1760 | 1370/545/1760 | 1710/925/1800 | 1710/925/1800 | 1810/955/1950 | |||
| Cooling | ℃ | 10-48 | |||||
| Ambienttemperaturerange | Heating | ℃ | -30-35 | ||||
| Domestichotwater | ℃ | -30-43 | |||||
| Cooling | ℃ | 5-25 | |||||
| Leavingwatertemperaturerange | Heating | 24-60 | |||||
| Domestichotwater | 30-75 | ||||||
MACON BESTCHOICEFORENERGYSAVING