WATER QUALITYINSTRUMENT
CATALOG
EX03 03
ProSwap Logger 06
ProDSS 11
ProQuatro 19
ProSolo ODO/T 21
YSI MultiLab Line 23
exo 3 Thtehre rht sondice!
The parameters you need, without the features you don't.
Offering the greatestvalue of any sonde availableinthemarket,EXO3combines the maneuverability of ExO1with the powerful antifouling wiper of the EXO2.
EXO3 is a purpose-built sonde for monitoring major water quality parameters, including: pH, conductivity,temperature,turbidity and dissolved oxygen.
But that's just the beginning of the great benefits EXo3 has to offer:
The best-priced, highestquality sonde for baseline water quality monitoring.
Flexibility to switch from continuousmonitoring to spot sampling with a lighter, shorter form factor.
Integral SDl-12 communicationsmakesitidealfor existing data collection platforms and installations, including stations that need easyreplacementofourlegacy6-Seriessondes.
Plug-and-play design with all existing EXO platform smart sensors, including Total Algae, fDOM, and Wiped Conductivity & Temperature.
The best antifouling wiper in the industry, protecting your sensors for up to 90 days in the harshest conditions. α
5-portsAvailable (4) sensors and (1) anti-fouling wiper
| EXO Sonde Selection Guide | exo | A | ||
| EXO1 | EXO2 | EXO2s | EXO3 | |
| Available Sensor Ports | 4 | 7 | 7 | 5 |
| BatteryLife | 90 days* | 90 days* | N/A | 60 days* |
| Length | 64.77 cm (25.50 in) | 71.1 cm (28.00 in) | 47.00 cm (18.5 in) | 58.67 cm (23.1 in) |
| Weight | 1.42 kg (3.15 Ib) | 3.60 kg (7.90 Ib) | 1.1 kg (2.43 Ib) | 2.0 kg (4.41 Ib) |
| SDI-12 Communications | with Adapter | with Adapter | with Adapter | Integral |
| Vented Level | √ | |||
| Antifouling Protection | ||||
| Auxiliary Expansion Port | √ | √ | ||
\*Battery life will depend on the type of sensors and measurement frequency.
EXOSmartSensorSuite
Ammonium·Barometer·Blue-Green Algae(PC&PE)·Chloride·Chlorophyll·Conductivity·Depth OpticalDissolved Oxygen·fDOM * Nitrate·ORP·pH·Salinity * Temperature·Turbidity
YSI.com/EXO3
See reverse forfull specifications andcontactinformation.
"I'm very proud of the great work our customers do using our best-in-class sonde platform."
Dr.Stephanie A.Smith EXO Product Manager
YSI.com/EXO
| LxoSSpecmcatiors 5 sensor ports (4 ports available when central wiper in use) | |
| Ports | Peripheral ports:1 power communication port |
| Size | Diameter: 7.62 cm (3.00 in)Length: 58.67 cm (23.1 in) |
| Weight | 2.00 kg (4.41 Ibs) with afullpayload of4 probes, 1 wiper, and probe guard installed |
| Operating Temperature | -5to 50°℃ (23to 122°F) |
| Storage Temperature | -20to 80°℃ (-4to 176°F). Exception: 0to 60°℃ (32to 140°F) forpHand pH/ORP sensors |
| Depth Rating | 0to 250 m(0 to 820ft) |
| Communications | Sonde: Bluetooth wirelesstechnology, USB, RS-485, and integral SDI-12 Output Options withAdapters:USB,RS-232,orModbus |
| Sample Rate | Upto 4 Hz |
| Data Memory | 512 MBtotal memory; >1,000,000 logged readings |
| Ordering Information | |
| 599503-00 | EXO3 Sonde with no depth sensor |
| 599503-01 | EX03 Sonde with 10m depth sensor |
| 599503-02 | EX03Sondewith100mdepthsensor |
| 599503-03 | EX03 Sonde with 250m depth sensor |
ProSwap Logger
ProSwap Logger is a single-port monitoring sonde based on proven YSl technology. With flexible sensor and deployment options, ProSwap Logger is a perfect solution for those looking to expand their water quality monitoring at an affordable price.
Proven Data Quality Swappable Sensors
Industry-leading smart sensor technology with on-board monitoring for improved calibration and performance
Customize your system with user-replaceable water quality sensors alongside built-in temperature and depth
Ti
Autonomous Logging Ultimate Durability User-Friendly Interface
Elevate your data collection with continuous monitoring and unattended deployments
Titanium housing and waterproof connections guaranteeoperation well into the future
Simplify fieldwork with quick setup, direct system integration, and intuitive data management
Monitoring Made Simple.
ProSwap Logger features a universal port for a wide variety of real-time monitoring applications. Combine any digital smart sensor with the built-in temperature and depth sensors for more comprehensive measurements in a slim profiling package. Build a dedicated system for conductivity, dissolved oxygen, pH, turbidity, or algae monitoring applications with unique customization options.
| ProSwap Logger Specifications | |
| Material Internal Logging Memory | Titanium 512 MB, >100,000 data sets |
| Capacity | (includes date,time, site,parameters) |
| Software | Kor Software |
| Communications | |
| Sonde | YSIP, SDI-12, Modbus* |
| Adapters | USB, Flying-Lead |
| Power | |
| External | |
| Powering | 5.4 - 16 V |
| Charging | 9 - 16 V |
| Internal | Rechargeable Li-lon battery |
| Temperature | |
| Operating | -5 to 50°C (23 to 122°F) |
| Storage | -20 to50°C(-4 to 122°F) |
| Depth Rating | 0 to 100 m (0 to 328) |
| Battery Life | ≥ 90 days at 15 min log interval |
| Sampling Rate | 1 per second (fastest)to 1 per day(slowest) |
| Sonde Dimensions | |
| Diameter | 2.65 cm (1.05") |
| Length (with guard) | |
| Without battery | 49.70 cm (19.57") |
| With battery | 57.35 cm (22.58") |
| Sonde Weight** | |
| With battery | 0.57 kg (1.25 Ibs) |
| Without battery | 0.45 kg (0.99 Ibs) |
| Warranty | 2 years |
Continuous Unattended Logging
Ideal for short- and long-term deployments, the on-board memory is capable of holding over 100,000 data set. With ProSwap Logger, you can view trends in water level and quality over extended periods oftime for a true representation of the ecosystem.
Flexible Deployment
ProSwap Logger is a powerful instrument in a small package. Suspend in groundwater wells deployment pipes, and othertight or shallow spaces. A variety of power and deployment options are available to fit the needs of your system.
Reliable Connection
An integral cable allows foreasy topside communication and data download without removing the sonde from its deploymentlocation.A twist-lock connectorprovidesquick andreliable communicationvia a dedicated handheld or Kor Software.
With convenient options for calibration, deployment setup, and data collection, ProSwap Logger makes it easier than ever to effectively expand yoursmartwatershed.
Extreme Flexibility
ProSwap Logger is extremelyflexiblewith customizablepower options, swappable sensors,and simple integration into existing field systems.
Critical Components
ConnectorCap
Protection for top-side cable connector(included withPSL)
Use
Autonomous deployments (PSL with internal battery)
PowerPack
Dedicated external power with6AAbatteriesformonths of logging
Use
Autonomous deployments (PSL without internal battery)
Flying Lead Adapter Simplifies connection to any monitoring system
Use
OutputSDl-12orModbus\* Supplyexternalpower
ProSwap Handheld
Quick and easy mobile interface
with color display
Rugged, ergonomic design
Alsocompatiblewith
ProDSShandheld!
USBAdapter
Direct connection to a PC running Kor Software Provides charging via USB port orACadapter
KorSoftware
Familiarinterfacefor instrumentanddata management
\*Modbus output configurable with post-launch update.
Digital Smart Sensors
ProSwap Logger is compatible with any individual ProDSS Digital Smart Sensor for fast, easy setup and high quality data.Each sensorfeatures awelded titanium body, auto-recognition,andlocal storage of calibration for quick swapping.Trusted by water monitoring professionals,these sensors provide accurate data with advanced technology and proven performance!
| Proswap Loge | |||
| Sensor Specifications | |||
| Sensor/Parameter | Range | Resolution | Accuracy |
| Temperature (DSSSensor) | -5 to 70 °℃(23to 158F) | 0.1 °℃ or 0.1°F | ±0.2°℃ |
| Temperature (ProSwap Logger) | -5 to 50 °C(23 to 122°F) | 0.1 °C or 0.1 F | ±0.15 ℃ |
| PH | 0 to 14 pH units | 0.01 pH units | ±0.2 pH units |
| ORP | -1999 to 1999 mV | 0.1 mV | ±20 mV |
| Disglved | 0 to 500%, 0 to 50 mg/L | 0.01. m/ and 1%. | 0 to 200%: ±1% of reading or 1% saturation, whichever is greater 25%fh |
| Conductivity | 0 to 200 mS/cm | 0.001, 0.01 or 0.1 mS/cm (range | 20 to 50 mg/L: ±8% of reading 0 - 100 mS/cm: ±0.5% of reading or.001 mS/cm, whicheveris greater 100 - 200 mS/cm: ±1.0% of reading |
| Specific Conductance* | 0 to 200 mS/cm | 0 - 100 mS/cm: ±0.5% of reading or.001 mS/cm, whichever is greater 15-200m/m:±10%ofreadiatre (15 to 25 °C; default 25 °C) and compensation coefficient(0 to | |
| Salinity* | 0 to 70 ppt | 0.01 ppt | 4%/C; default 1.91%) ±1.0% of reading or ±0.1 ppt, whichever is greater |
| Tetal Dssolved solis | Oto 100 g/L | 0.001, 0.01, 0.1 g/L | |
| Resistivity* | O to 2 Mohms | 0.001, 0.01, 0.1 ohms | ±0.1% Full Scale |
| Seawater Density* | 0.0 to 50.0 sigma, sigma T | 0.1 sigma or sigma T | |
| Turbidity | 0 to 4000 FNU | 0.1 FNU | 0 to 999 FNU: 0.3 FNU or ±2% of reading, whichever is greater 1000 to 4000 FNU: ±5% of reading |
| TAL-Chlorophyll | 0 to 100 RFU or 0 to 400 μg/L chl | 0.01 FL r | Linearity:r2 ≥ 0.999 for Rhodamine WT across full range |
| TAL-Phycocyanin | Oto 40 RFL PC | ||
| TAL-Phycoerythrin | O to 40 BFL PE | ||
| Ammonium** | 0 to 200 mg/L NH-N | 0.01 mg/L | ±10% of reading or 2 mg/L, whichever is greater |
| Chloride** | 0to 18000 mg/L Cl | 0.01 mg/L | ±15% of reading or 5 mg/L, whichever is greater |
| Nitrate** | 0 to 200 mg/L NO-N | 0.01 mg/L | ±10% of reading or 2 mg/L, whichever is greater |
| Depth | 0to 100 m(0 to 328 feet) | 0.001 m or 0.001 ft | ±0.004 m for 1, 4, and 10 m cables ±0.04 m for cables 20 m and longer |
| Vented Level | 0 to 10 m (0 to 32.8 feet) | 0.001 m or 0.001 ft | 0.003 m (±0.01 ft) |
Customize your Professional Digital Sampling System to meet the demands of your water quality monitoring application.
With 21 parameter options and several cable configurations to choose from, the ProDsS is ideal for field or lab use in nearly any application: surface water, groundwater, coastal waters, aquaculture,andwastewater.
ProDSS
口 Rugged 国 Handheld
The ProDSS Handheld can withstand the harshest field conditions and handling, with maximum versatility and functionality.
· Easy-to-read color and backlit display can be used in any
lighting condition
· Scratch-resistant screen is viewable with polarized glasses
· Long-life rechargeable lithium-ion battery ensures
reliability in the field and minimizes waste
· Waterproof (IP-67) rubber over-molded casing
· Simple interface and a dedicated "Help" Button
· Ergonomic design for optimal handling and portability
· Optional GPS for geo-referencing data
· 3-year warranty
"I like the LCD display because of its ease of use in low and high light areas... the increased memory size and speed are also very nice for logging data."
ProDSSUser
Smart Sensors
The 4-Port ProDSS cable uses digital Smart Sensors for fast, easy setup and storage, and highest quality data.
· Universal smart Ports allow any configuration of sensors
·Traceable calibrations stored in sensor - recalibration not required if moved to another port or anotherinstrument
· Sensors are auto-recognized upon installation
·Replaceable sensor modules and ODO cap reduces maintenance and cost of operation
· Highly-ruggedized, welded titanium sensor body
· 2-year warranty
WaterQualityParameters:
Depth
GPS Coordinates
Ammonium
Ammonia
Chloride
Nitrate
Temperature
Barometric Pressure
Total Algae
Chlorophyll
Dissolved Oxygen (Optical)
Turbidity
pH
ORP/Redox
Conductivity
Specific Conductance
Salinity
Total Dissolved Solids (TDS)
Resistivity
Seawater Density
Total Suspended Solids (TSS)
Reliable Cables
Not just a power cord! ProDSS cables minimize electrical noise and signal degradation over any cable length.
· Single-line design for easy handling in the field
· MS (Military Spec) locking connector for secure connection
· Cable lengths up to 100 meters
· Sensor guard weights for vertical profiling and stability
· 2-year warranty
Multiparameter4-PortCableAssembly ODO/TandODO/CT
· Universal smart ports · Optional depth sensor
ProSwap 1-Port Cable Assembly
· Universal smart port · Built-in temperature sensor · Optional depth sensor · Just over 1-inch diameter
ProbeandCableAssemblies
· Temperature and ODO in one sensor · Optional built-in conductivity · Less than 1-inch diameter ·Rugged ODO sensor cap with 2-year warranty
ProOBODProbe and Cable Assembly
·TaperedprobeforBODbottles · Quiet, self-stirring · Guarded sensor cap
Powerful Data Management
Kor Software
· Powerful Kor Software is included with all systems
·Transfer instrument configurations to multiple Handhelds
· Transport data directly from handheld or USB
· Conduct real-time studies
· Enhance data with site images
| ProDSS General Specifications | |
| Auto Stable | User-defined auto-stable function holds stable readings on display when criteria is met |
| Buffer Recognition | Auto buffer recognition and temperature compensation for US and NIST buffers |
| Cable Connector | MS (military spec) waterproof with bayonet lock |
| Calibration Points | 1, 2, or 3 pointfor pH, Turbidity,Ammonium,Nitrate, and Chloride; 1 or2 point forDO; 1 point for ORP, Barometer, Conductivity,Specific Conductance,Salinity,and Depth |
| Certifications | CE; RoHS; IP-67; WEEE; FCC; UN Part Il, Section 38.3, Test methods forlithium-ion batteries(Class 9) |
| Connectivity | Builtin micro USB; Cable for PC connection and cable for connectionto USB memory stick are included |
| Data Management | Kor desktop software included; 100 user-defined Data ID tags and 100 Sites with GPS coordinates |
| Data Memory | >100000 data sets(data, date,time, user-defined info); 100 files |
| Dimensions | Handheld is 8.3 x 21.6 x 5.6 cm |
| Display | Color, LCD graphic display; 3.9 x 6.5 cm |
| GLP Compliance | Yes; 400 detailed GLP records can be stored and are available to view, download and print |
| GPS | Optional internal GPS; coordinates are stored with measurement data and site lists |
| Languages | English,panish,German,French, Italian,Norwegian, Poruguese,Japanese, Chinese (Simlifd &Traditional) Korean, Thai |
| Logging Modes | Single Point or Continuous |
| Operating Temperature | 0to50°C |
| Password Protection | Calibration menu can be password protected to prevent unauthorized sensor calibration |
| Battery | Rechargeable lithium-ion battery pack provides ~20 hours with the handheld, 4 port cable and 4 smart sensors; battery recharge time is ~9 hours with the AC power adapter |
| Storage Temperature | 0 to 45° C with battery installed; 0 to 60° C without battery installed |
| Recalibration Prompt | Provides reminder to recalibrate a ProDSS sensor after user-defined number of days |
| User ID | Optional user ID for data security |
| USB Port | Builtin micro USBOn-The-Go port for PC connection, recharging/powering the ProDSS and connecting directly to a USB stick |
| Warranty | 3-year:2-yearbulkhead,cable assembly, sensors; and ODOExtended Warranty cap;1-yearpH and pHORensrodlesnsrapndinatyackntniumitratd chloride sensor modules |
| Waterproof | IP-67 ; floats |
| Weight with Batteries (Handheld) | 567 grams (1.25 Ibs) |
"The meter, cable, and sensors are sturdy,wellprotectedforfieldwork, well designed, and professional."
ProDsS User
| Sensor/ Parameter | Range | Resolution | Accuracy |
| Temperature | -5 to 70 °℃(23to 158F) Temerarture mompensation | 0.1 °℃ or 0.1F | ±0.2°℃ |
| measurement: -5 to 50 °℃ | |||
| pH ORP | 0 to 14 pH units -1999 to 1999 mV | 0.01 pH units 0.1 mV | ±0.2 pH units ±20 mV |
| Disglved | 0 to 200%:±1% of reading or 1% saturation,whichever is greater 25%d%ofagwhhrsge | ||
| Barometer | 375 to 825 mmHg | 0.1mmHg | 20 to 50 mg/L: ±8% of reading ±1.5 mmHg from 0to 50 °℃ |
| Conductivity | 0 to 200 mS/cm | 0.001, 0.01 or 0.1 mS/cm (range | 0 to 100 mS/cm: ±0.5% of reading or 0.001 mS/cm, whichever is greater 100 to 200 mS/cm: ±1.0% of reading |
| Spndiuictancet | 0 to 200 mS/cm | 0.0 m150.0m. | 0 to 100 mS/cm: ±0.5% of reading or 0.001 mS/cm, whichever is greater 1t2%ofea (15 to 25 °℃; default 25 °C) and compensation coefficient(0 to |
| Salinity* | 0to 70 ppt | 0.01 ppt | 4%/°C; default 1.91%) ±1.0% of reading or ±0.1 ppt, whichever is greater |
| Totad isslved | 0to 100 g/L | 0.001, 0.01, 0.1 g/L | Callae |
| Resistivity* | O to 2 Mohms | 0.001, 0.01, 0.1 | ±0.1% Full Scale |
| Seawater Density* | 0.0 to 50.0 sigma, sigma T | ohms 0.1 sigma or sigma T | |
| Turbidity | 0 to 4000 FNU | 0.1 FNU | O to 999 FNU: 0.3 FNU or ±2% of reading, whichever is greater |
| TAL-Chlorophyll | 0 to 100 RFU or 0 to 400 μg/L chl | 1000 to 4000 FNU: ±5% of reading | |
| TAL-Phycocyanin | O to 40 RFULPC | 0.01 FUL r | Linearity: r2 ≥ 0.999 for Rhodamine WT across full range |
| TAL-Phycoerythrin | O to 0 RFU PE | ||
| Ammonium** | 0 to 200 mg/L NH-N | 0.01 mg/L | ±10% of reading or 2 mg/L, whichever is greater |
| Ammonia* | 0 to 200 mg/L NH4-N | 0.01 mg/L | ±10% of reading or 2 mg/L, whichever is greater |
| Chloride** | 0 to 18000 mg/L Cl | 0.01 mg/L | ±15%of reading or5mg/L,whicheveris greater |
| Nitrate** | 0 to 200 mg/L NO3-N | 0.01 mg/L | ±10% of reading or 2 mg/L, whichever is greater |
| Depth | 0 to 100 m(0 to 328 feet) | 0.001 m or 0.001ft | ±0.004 m for 1, 4, and 10 m cables ±0.04 m for cables 20 m and longer |
ProQuatro PORTABLEMULTIPARAMETERWATERQUALITYMETER
Tougher, Smarter, More Versatile
TheProQuatro handheld multiparameter metermeasures a variety of combinations of dissolved oxygen, conductivity, specific conductance, salinity, resistivity, total dissolved solids (TDS), pH, ORP, pH/ORP combination, ammonium(ammonia),nitrate,chloride and temperature.
In addition to itsimpact-resistant,waterproof case,theProQuatro has features that make field sampling faster and easier:
User-replaceable cablesandsensors
Real-time salinity compensation of DO measurements
Built-in micro USB port for easy datatransfertoflashdrive
Quick response times
ProSolo ODO/TOPTICALDISSOLVEDOXYGENANDTEMPERATURE METER
DON'TGOITALONE.GOSOLO
The ProSolo DIGITAL handheld meter is designed for use with YSl's latest Optical Dissolved Oxygen and Temperature (ODO/T) probes as well as legacy ProODO and ProOBOD probes.
Combining an extremely durable, user-friendly display with the most advanced DOtechnology,ProSolo stands alone as theindustry's best dissolved oxygen meter at an exceptionally affordable price.
What doyou get if you GoSolo?
3-year warranty on handheld, 2-year warranty on probe/cable assembly and ODO sensor cap
Highly-accurate ODO? sensor technology with no stirring
Rechargeablelithium-ionbatterythat supports a full day of sampling
YSIMultiLab Line
BenchtopInstrumentsfor the Lab
Parameters:
Temperature
Conductivity
Resistivity
Salinty
TDS (Total Dissolved
Solids)
pH/mV
Oxidation Reduction
Potential(ORP)
Partial Pressure
Dissolved Oxygen (%
and mg/L\*(BOD)
\*Optical Based
The YSl MultiLab line of instruments provide easy to use and easyto-calibrate menu-driven operation ideal for any laboratory.These one,two,orthree channel benchtop meters forthe measurement of pH, ORP, conductivity and/or optical-based dissolved oxygen (BOD) are ideal for highly accurate lab testing.
The instruments feature a large, easy to read display, Intelligent Digital Sensors (IDS) for plug-and-play connectivity, and a 3-year instrument warranty.
Model 4010-1-OneChannel
·Single channel input for pH, ORP, Optical-Based
DO/BOD, or conductivity
·Data storage-500 data sets in manual mode;
5,000 data sets in automatic logging mode
·Large,easyto read backlit graphic display
· GLP Compliant (sensors store serial # and calibration data) ·USB connectivity to manage data
· 3-year warranty
Models4010-2and4010-3 -Two and ThreeChannel
·Two or Three channel input for pH, ORP,
Optical-Based DO/BOD, or conductivity
·Data storage-500 data sets in manual mode;
10,0o0 data sets in automatic logging mode
·Large, easy to read color display
· GLP Compliant (sensors store serial # and calibration data) ·Antibacterial keypad
· USB connectivity to manage data
· 3-year warranty
Intelligent Digital Sensors (IDS)
The IDS sensors automatically store their unique serial number and calibration data. The sensors maintain their calibration data when moved from instrument to instrument and transmit this information to the new instrument so you don't have to recalibrate. In addition,they also digitally process the measurement signal.
·Plug-and-play connectivity in any combination with all MultiLab instruments · Sensors store their own unique ID with serial number and calibration status · Automatic sensor recognition with digital signal processing and data transfer · Includes self-stirring Optical-Based DO/BOD, pH, ORP, and conductivity sensors
CMC
The CMC function displays continual monitoring of the sensor's measuring range. The range is represented with a bar and calibration points are shown as vertical lines at the cal point. A moving cursor shows the current measured value and indicates if the measurement is within the calibrated range.
Quality Sensor Control (QSC)
The QSC is a system to monitor the condition of the pH electrodes. An initial calibration is performed and, afterwards, the sensor status is monitored and graphically displayed.
TheYSIIDSProOBODselfstirring optical BODprobe, powered by the instrument, has a built-in sensor guard to protect the sensing tip from damage while placing it into theBODbottles.
Superior Benchtop Measurement
The MultiLab line provides high accuracymeasurementsforthelab.
Measure conductivity, pH, ORP, or DO for BOD calculations confidently and quickly with the full range of IDS sensors. Also capable of using nonI D S_{P}H orORPsensorswithasimple adapterforsensorswithDiNorBNC connectors.
| MultiLab Line Benchtop Sensor Specifications | ||||
| pH103740Yand103741Y | pH103750Y | pH 103780Y(refillable) | ORP103790Y(refillable) | |
| pH Range Temperature Range | 0.000 to 14.000 (±0.004*) 0 to 80°C(32 to 176F) | 0 to 80°℃(32 to 176°F) | 0to 100°℃(32to 212F) | -1200to +1200 mV(±.2 mV) 0 to 100°C(32to 212°F) |
| Temperature Accuracy | ±0.2°℃ | ±0.2°℃ | ±0.2°℃ | ±0.2°℃ |
| Reference Electrode | Gel | 3 mol/ KCI | 3 mol/I KCI | 3mol/l KCl |
| Membrane Shape | Cylinder | Cylinder | Cone | |
| Diaphragm | Fiber | Ceramic | Platinum Wire | Ceramic |
| Material | Plastic | Plastic | Glass | Glass |
| Dimensions | Length 120 mm(4.7in); diameter 12 mm(0.47in)forall sensors | |||
| Warranty | 1year | 1 year | 1 year | 1 year |
| Cable Length | 1.5 m | 3m | 1.5 m | 1.5 m |
| Cond301710Yand301711Y | ||||
| Type | Cond301720Y 2-electrode,stainlesssteel | |||
| Conductivity Range | 4-electrode, graphite | 0.01μS/cm to 200 μS/cm ±(0.5% of value) | ||
| Resistity | 10 μS/cm to 2,000 mS/cm (±0.5% of value) | 5 k0hm cm to 100 M0hm cm (±0.5% of value) | ||
| Salinity | 0.5 0hm cm to 100 k0hm cm (±0.5% of value) | |||
| Total Dissolved Solids | 0.0 to 70.0 ppt (±0.5% of value) | |||
| Temperature Range | 0 to 1,999 mg/L; 0.0 to 199.9 g/L (±0.5% of value) | 0to 100℃(32 to 212F) | ||
| Temperature Accuracy | 0to 100℃(32 to 212F) ±0.2°℃ | ±0.2°℃ | ||
| Cell Constant | 0.1 cm ±2% | |||
| Material | 0.475 cm ±1.5% Epoxy | Stainless Steel | ||
| Dimensions | Length 120 mm (4.7 in); diameter 15.3 mm (0.6 in) | Length 120 mm (4.7 in); diameter 12 mm (0.47 in) | ||
| Warranty Cable Length | 2 years 301710Y-1.5m,301711Y-3m | 2years 1.5m | ||
| OpticalB0D626500 | ||||
| Type Dissolved Oxygen Range | Optical; lifetime luminescence detection with self-stirring mechanism | |||
| 0 to 50 mgl;0to 500% air saturation | ||||
| Dissolved Oxygen Accuracy** | 0to 20 mg/, ±0.1 mg/L or ±1% of reading, whichever greater; 20 to 50 mg/L,±10% reading (system) | |||
| Dissolved Oxygen Resolution | 0.01 mg/L; 0.1% | |||
| Temperature Range | Ambient10 to 40°C(50to 104°F); Compensation mg/L-5to 50°C(23to 104°F)(extrapolates beyond 45°C) | |||
| Temperature Accuracy | ±0.2°℃ | |||
| Temperature Resolution | 0.1℃ | |||
| Typical Response Time | 95% in 22seconds with stirring;95% in40 seconds without stirring | |||
| Warranty | 2 years; 1 year DO sensor cap | |||
\*accuracy of sensor electronics \*\*accuracy of system including probe, cable & instrument
Data Management
Beyond simply viewing data on the highly visible, graphic displays data can also be managed with the following features:
·send real time data AND stored data to thePCvia USB in.csv and ASCll formats. Capable of interfacing with LIMS.
·abilityto transfer stored data in ASCll and.csvformats viaUSB memory stick (4010-2 and 4010-3 only)
· ability to send data to external printers (4010-2 and 4010-3 only)
·works with BOD Analyst Pro desktop software to automatically calculateBODvalues
BOD Analyst Pro desktop software forthe calculation of BOD's.
| Model 4010-1 | Model4010-2andModel4010-3 | |
| Measurement Channels | 1 | 2 (4010-2) or 3(4010-3) |
| Data Storage | 500 data sets manual; 5,000 automatic | 500 data sets manual; 10,000 automatic |
| Interface | MiniUSB | Mini USB; USB-A |
| Display | Graphic, Backlit | Color, Graphic, Backlit |
| Power Supply | Universal power supply; 4 AA1.5 Vbatteries | Universal power supply |
| AllModels(4010-1,4010-2,4010-3) | ||
| Parameters | pH,ORP(m), ptical-Basd D%,DOmg/(BD proe), Parial Presure, Cndctivity, Reistivity,ainity,TD | |
| Temperature Compensation | Yes; except ORP | |
| Calibration Points | DO and Conductivity = 2; pH = 1 to 5 | |
| Calibration Storage | Max. 10 | |
| Calibration Timer | 1 to 999 days | |
| GLP/AQA Compliant | Yes | |
| Cerifications | CE, ETLus | |
| Warranty | 3years | |
| Warranty | CL,CLTEUS 3years |
| MultiLab Line Ordering Information | |
| 1FD350Y | 4010-1OnechannelDSbenchtop instrument;universal powersupply;electrodestand;manual; software andUSBcable |
| 1FD460Y | 4010-2TwochannelIDSbenchtopinstrument;universalpowersupply;electrodestand;manual; sofwareandUBcable |
| 1FD470Y | 4010-3Three chanelIDSbenchtopinstrument;universal powersupply;electrode stand;manual;software andUcale |
| 626570 | BOD Lab Kit-Includes 4010-1One Channel benchtop instrument(1FD350Y)and Optical BOD probe(626500) |
| 626571 | Advanced BODLabKit-Includes4010-1ne Channelbenchtop instrument(1FD350Y),OpticalOD probe(626500)and BODAnalyst |
| Pro desktop software forthe calculation of BODs(625120) | |
| 626572 | pH Lab Kit-Includes 4010-1One Channelbenchtopinstrument(1FD350Y)and DoubleJunction pHelectrode(103740Y) |
| 626573 | BOD/pHLabKit-Includes4010-2TwoChannelbenchtopinstrument(1FD460Y),OpticalBODprobe(626500)and DoubleJunctionpH electrode(103740Y) |
| 626574 | Advanced BODpHLabKit-Includes4010-2wo Channelbenchtopinstrument(1FD460Y),Optical OD probe(626500), Double |
| Junction pHelectrode(103740Y)and BODAnalyst Pro desktop software forthe calculation of BODs(625120) | |
| 103740Y(4110) 103741Y(4110-3) | pH, Plastic,Gel,Digital,Double Junction, 1.5 m(~5 ft) cable |
| pH,Plastic,Gel,Digital,Double Junction,3 m(~10 ft)cable | |
| 103750Y(4120) | pH, Plastic, 3 mol KCl, Digital, Double Junction, 1.5 m(~ 5 ft) cable |
| 103780Y(4130) | pH,Glass,3mol KCl, Digital,Double Junction, 1.5 m(~ 5 ft) cable |
| 103790Y(4210) | ORP,Glass, Digital, Double Junction, 1.5 m(~ 5 ft) cable |
| 301710Y(4310) | Conductivity, Epoxy,4-Graphite Electrodes, Digital,1.5 m(~ 5ft) cable |
| 301711Y(4310-3) | Conductivity,Epoxy,4-Graphite Electrodes,Digital,3m(~ 10 ft) cable |
| 301720Y(4320) | Conductivity,StainlessSteel, 2-Electrodes,Digital,1.5 m(~5 ft)cable |
| 626500 | Optical Dissolved Oxygen;Self-Stirring,BODProbe,2m(~6.5 ft) cable |
| 109830Y | Calibration Kit for IDS pH Electrodes ;3 ampules; pH 4.01,6.86,9.18 |
| 108131Y | pH Adapter DIN for4010-2 and 4010-3 |
| 101132Y | pHAdapterBNCfor4010-2and4010-3 |
| 902867 | Universal Power Supply |
| 109813Y | Stand plus holder for electrodes |
| 902883 | USB cable for connecting instrument with USB-Mini Bto a PC |