H.Stars Explosion-proof Chiller
Functionsand featuresof explosion-proof chiller
Asa kind of special air-conditioning equipment,explosionproof equipment and its components are manufactured in strict accordance with relevant requirements of GB3836, anational explosion-proof standard,and explosion-proof certificateshallbeobtained forit.Itcanbeused inspecial places of high explosionor fire risk,as well as in ordinary circumstances.It is widely used in various industries, including petroleum,chemical,textile,printing,medicine, and food industries.Flameproof or positive pressure type ofexplosion proof equipment can be chosen based on the characteristics of the project.Our Explosion proof equipment have two explosion proof levels,Exd IIBT4and Exd IIC T4;other explosion level is also available according to user requirements.
Explosion proof certificates
Explosion-proof compressors
Explosion-proof compressors are produced in accordance with the national standard GB3836, have the explosion proof symbol of Exdib mb IIBT4Gb or Exde mb II BT4Gb,have passed the national inspection,and have obtained explosion proof certificates.Itsmainapplication isin Zones1and2in the petroleum,chemical industry,metallurgy,pharmaceutical and national defense industries,where explosive gas mixture exists in the air.
Explosion-proof electrical cabinet
Explosion proof mark:Exd ib IIBT4 Gb
The electrical cabinets come in flameproof and positive pressure types;with theircasemadeof steel plates,they are strongand durable;and theyalso have an NWN entry system.
Flameprooftype:itisusedinexplosivemixtureinvadesinto thecabinet and explodes due to some reason,it will not cause explosion of the explosive mixture outside the cabinet. Positive pressure type:Positive pressure ventilated explosion proof electrical cabinet achieves explosion prevention by usingpropermedium to isolate ignitionsource.
Explosion-proof fan
Theyare produced in accordance with the national standard GB3836,have the explosion proof symbol of Exd Il CT4Gb bypassed national inspection,and have obtained explosion proof certificates.
Explosion-proof components
Air-cooled explosion-proof screw chiller
| Standardconfiguration | |
| Compressor | Explosion-proof screw compressor |
| Evaporator | Self-developedhighperformanceevaporator |
| Condenser | Self-developed high performance finned tube condenser |
| Electrical control cabinet | explosion proof electrical control cabinet |
| Flow control device | Thermostatic/electronicexpansionvalve |
| Fan | Explosionproofmotorfan |
| Cable | Explosion proof cable |
| Thermal insulation materials | Antisepsis,waterproof,andreticularthermal insulation layer |
| Package | High-strength plastic sheet |
| Connection of water pipeline | Flange |
Air-cooled explosion proof scroll chiller
| Standardconfiguration | |
| Compressor | Explosion proof scroll compressor |
| Evaporator | Self-developedhighperformanceevaporator |
| Condenser | Self-developed high performance finned tube condenser |
| Electricalcontrol cabinet | explosionproof electrical control cabinet |
| Flow control device | Thermostatic expansionvalve |
| Fan | Explosion proof motor fan |
| Cable | Explosion proof cable |
| Thermal insulation materials | Antisepsis,waterproof,andreticularthermal insulation layer |
| Package | High-strength plastic sheet |
| Connection of water pipeline | Flange |
Water-cooled explosion-proof screwchiller
| Standardconfiguration | |
| Compressor | Explosion-proofscrewcompressor |
| Evaporator | Self-developedhighperformanceevaporator |
| Condenser | Self-developed high performance condenser |
| Electricalcontrolcabinet | explosion proof electricalcontrolcabinet |
| Flow control device | Thermostatic/electronicexpansionvalve |
| Cable | Explosion proof cable |
| Thermal insulation materials | Antisepsis,water proof,and reticular thermal insulation layer |
| Package | High-strength plasticsheet |
| Connectionof water | Flange |
Water-cooled explosion proof scroll chiller
| Standardconfiguration | |
| Compressor | Explosionproofscrollcompressor |
| Evaporator | Self-developedhighperformanceevaporator |
| Condenser | Self-developed high performance finned tube condenser |
| Electricalcontrolcabinet | explosionproof electrical control cabinet |
| Flow control device | Thermostatic expansion valve |
| Cable | Explosionproof cable |
| Thermal insulation materials | Antisepsis,water proof,and reticular thermal insulation layer |
| Package | High-strength plasticsheet |
| Ppenection of water | Flange |
Evaporative condenser explosion-proof screwchiller
| Standardconfiguration | |
| Compressor | Explosion-proof screw compressor |
| Evaporator | Self-developed high performanceevaporator |
| Condenser | Explosion-proof evaporative condenser |
| Electrical controlcabinet | explosion proof electrical controlcabinet |
| Flowcontrol device | Thermostatic/electronicexpansion valve |
| Fan | Explosion proofmotor fan |
| Cable | Explosion proof cable |
| Thermal insulation materials | Antisepsis,waterproof,andreticularthermal insulation layer |
| Package | High-strength plastic sheet |
| Connection ofwater | Flange |
Selection of explosion-proof chiller
| Usage* | □Central air conditionerolndustrial coolingandfreezing equipment□ Hotwaterequipment |
| Refrigerating/Heating* | □kW provision □Material provision |
| Applicableareacategory* | □l□lA□BlC |
| Explosion proof temperature level* | □T1□T2T3T4□T5 |
| Cooling mode* | □AirWaterEvaporativecondenserDual |
| Power supply* | □380V □4kV □6kV10kV |
| Power frequency | □50Hz □60Hz |
| Refrigerant type* | □R22□R1343a□R407C□R404A□R410A□R507 |
| Compressortype | □Screw Scroll |
| Control mode | □PLC |
| Inlet/Outletwatertemperature | □Standard oNon-standard |
| Coolingmedium | □Water Non-standard |
| Otherrequirements | □Customization |
Relevant standards of explosion proof
Equipment is in strict compliance with national standards:
GB3836.1-2010:Explosive atmospheres-Part 1: Equipment-General requirements.
This Part specifies general structure,testing and label requirements for electrical equipment and Excomponents forapplication in explosiveatmospheres.
Suitableforuseunderstandardatmosphereconditionsin thefollowingdangerousplaceswhereexplosiveenvironment exists:
Temperature:-20℃ ~ + 6 0 ^ { \circ } { \mathsf C }
Pressure:80kPa\~110kPa;
Standard oxygen content (volume ratio): 2 1 % #
Specialconsiderationsshallbe takenforelectrical equipment to beused beyond the atmosphere conditions mentionedabove.
Itisrecommendabletoconsider thesituationcombinedof explosivegasatmosphereandcombustibledustatmosphere andtakeadditional precautions.
Ignitionsourcesnotconsidered inthisPartinclude:adiabatic compression,shockwave,exothermicchemicalreaction, spontaneous combustion of dust,open flames,and hot gas/ liquid.
Electrical equipment is classified into three types:Type l, Type Il,andType Ill.
Type丨 electrical equipment isused in places where coal seam gas exists.
Type ll electrical equipment isused in placeswhere there is explosive gasother than coal seam gas.
Type Ill electrical equipment is used in explosive dust atmospheresother thancoal mines.
GB3836.2-2010:Explosiveatmospheres- Part2: Equipmentprotectionbyflameproof enclosures“d"
ThisPart specifies special structure and testing requirements forelectrical equipmentprotectedby flameproof enclosures “d" for application in explosive atmospheres.
GB3836.5-2010:Explosiveatmospheres-Part5:Equipment protectionbypositivepressure case“p”
ThisPartspecifiesspecialstructureand testingrequirements forelectrical equipment protected by positive pressure case "p"forapplication inexplosiveatmospheres.
GB3836.4-2010:Explosiveatmospheres-Part4:Equipment protectionbyintrinsicsafety“i”
ThisPartspecifiestermsofart,structure,testingand label requirements for electrical equipment protected by intrinsic safety“i”forapplicationinexplosiveatmospheresand for associatedelectricalapparatusinexplosiveatmospheres connectedwithintrinsicallysafecircuit.
GB3836.9-2014:Explosive atmospheres-Part9:Equipment protectionbytypeof protection“m”
This Part specifies special structure,testing and label requirements for electrical equipment,equipment parts and Ex components protected by type of protection“m"for application in explosiveatmospheresand explosive dust atmospheres.
GB3836.15-2000:Electricalapparatusforexplosive gas atmospheres-Part15:Electricalinstallationsinhazardous areas (otherthanmines)
This Part specifies design,selection,and installation requirements forelectrical installation in explosive atmospheres.
Thisstandardisapplicabletoinstallationofallelectrical equipmentin hazardousareas.
Thisstandardisnotapplicabletoelectrical installationin coalmines.
ScrewType Water-cooled Explosion-proof ChillerTechnical Parameters
| 19 Model | Cuppiy | |||||||||||||||
| kW | USRT | |||||||||||||||
| 40STD-FB440WS4 | 438 | 125 | 83 | 92 | 5" | 90 | 1 | 53 | 4 | 75 1 | 68 | 76 2840 | 3060 | |||
| 40STD-FB530WS4 | 532 | 151 | 100 | 0 50 75 100 | 109 | 5″ | 109 | 1 | 56 | 5" | 91 1 | 70 | 77 | 3100 3380 | ||
| 40STD-FB610WS4 | 615 | 175 | 115 | 126 | 5" | 126 | 1 | 54 | 5" 106 | 1 | 69 | 77 | 4100 | 4410 | ||
| 40STD-FB690WS4 | 691 | 196 | 128 | 140 | 5" | 141 | 1 | 56 | 5″ 119 | 1 | 70 | 77 | 4520 | 4890 | ||
| 40STD-FB800WS4 | 805 | 229 | 146 | 163 | 5" | 164 | 1 | 58 | 5" 138 | 1 | 72 | 78 | 4740 | 5190 | ||
| 40STD-FB880WS4 | 866 | 246 | 158 | 179 | 6" | 176 | 1 | 58 | 6″ 149 | 1 | 73 | 78 | 5130 | 5620 | ||
| 40STD-FB940WS4 | 943 | 268 | 172 | 191 | 6" | 192 | 1 | 73 | 6" 162 | 1 | 88 | 79 | 5810 | 6340 | ||
| 40STD-FB1060WS4 | 1064 | 303 | 195 | 216 | 6″ | 217 | 1 | 76 | 6” 183 | 1 | 91 | 79 | 6230 | 6760 | ||
| 40STD-FB1290WS4 | 1199 | 341 | 219 | 264 | 8" | 244 | 1 | 79 | 8 206 | 1 | 94 | 80 | 6750 | 7460 | ||
| 40STD-FB1520WS4 | 1536 | 437 | 272 | 310 | 8″ | 311 | 1 | 80 | 8″ | 264 1 | 95 | 81 7890 | 8600 | |||
| 40STD-FB1740WS4 | 1782 | 507 | 313 | 357 | 8" | 360 | 1 | 81 | 8" | 306 | 1 | 96 | 82 8989 | 10370 | ||
| 40STD-FB1110WD4 | 1111 | 316 | 204 | 228 6" | 226 | 1 | 56 | 6″ | 191 | 1 | 70 | 82 4820 | 5450 | |||
| 40STD-FB1220WD4 | 1230 | 350 | 230 | 0 25 37.5 50 62.5 75 | 252 8" | 251 | 1 | 56 | 8" | 212 | 1 | 70 | 82 | 5620 | 6170 | |
| 40STD-FB1380WD4 | 1382 | 393 | 256 | 281 | 8″ | 282 | 1 | 58 | 8″ 238 | 1 | 72 | 83 | 5810 | 6260 | ||
| 40STD-FB1600WD4 | 1610 | 458 | 292 | 326 | 8" | 327 | 1 | 58 | 8" 277 | 1 | 73 | 83 | 5980 | 6440 | ||
| 40STD-FB1880WD4 | 1886 | 536 | 344 | 383 | 8 | 383 | 1 | 73 8" | 324 | 1 | 88 | 84 | 9970 | 11190 | ||
| 40STD-FB2120WD4 | 2128 | 605 | 390 | 87.5 100 | 10" | 433 | 1 | 76 | 10" | 366 1 | 91 | 84 | 10350 11770 | |||
| 40STD-FB2580WD4 | 2398 | 432 527 | 10″ | 488 | 1 | 79 | 10″ | 412 1 | 94 85 | 12820 | 14450 | |||||
| 40STD-FB3040WD4 | 3072 | 682 873 | 438 | 621 | 12" | 622 | 1 | 80 | 10" | 528 | 1 | 95 | 86 15890 | 17910 | ||
| 40STD-FB3480WD4 | 3564 | 1013 | 544 626 | 714 | 14″ | 721 | 1 | 81 | 12″ | 613 1 | 96 | 87 | 16720 | 18960 | ||
Screw Type Water-cooled Explosion-proof ChillerTechnical Parameters
| 9 Model | Nomlnal | -501Z | |||||||||||||||
| KW | USRT | ||||||||||||||||
| 40STD-FBM440WS4 | 298 | 85 | 53 | 68 | 5" | 60 | 1 | 50 | 4" | 51 | 1 | 65 | 76 | 2700 | 2930 | ||
| 40STD-FBM530WS4 | 340 | 97 | 60 | 75 | 5" | 69 | 1 52 | 5″ | 58 | 1 | 68 | 77 | 2880 | 3150 | |||
| 40STD-FBM610WS4 | 400 | 114 | 70 | 81 5" | 81 | 1 | 52 | 5" | 69 | 1 | 65 | 77 | 3600 | 3960 | |||
| 40STD-FBM690WS4 | 449 | 128 | 78 | 98 5″ | 91 | 1 | 54 | 5″ | 77 | 1 | 68 | 77 | 4100 | 4370 | |||
| 40STD-FBM800WS4 | 516 | 147 | 90 | 0 50 | 119 5" | 104 | 1 | 56 | 5" | 89 | 1 | 70 | 78 | 4410 | 4910 | ||
| 40STD-FBM880WS4 | 572 | 163 | 98 | 75 | 136 6″ | 115 | 1 | 50 | 6" | 98 | 1 | 70 | 78 | 4730 | 5180 | ||
| 40STD-FBM940WS4 | 615 | 175 | 106 | 149 6" | 124 | 1 | 55 | 6" | 106 | 1 | 70 | 79 | 5360 | 5590 | |||
| 40STD-FBM1060WS4 | 719 | 204 | 121 | 162 6″ | 144 | 1 | 58 | 6" | 124 | 1 | 75 | 79 | 5670 | 6190 | |||
| 40STD-FBM1290WS4 | 823 | 234 | 140 | 183 8" | 166 1 | 60 | 8" | 142 | 1 | 78 | 80 | 6170 | 7070 | ||||
| 40STD-FBM1520WS4 | 1047 | 298 | 174 | 225 | 8″ | 210 1 | 75 | 8″ | 180 | 1 | 82 | 81 | 7250 | 8060 | |||
| 40STD-FBM1740WS4 | 1171 | 333 | 192 | 306 | 8" | 234 | 1 76 | 8" | 201 | 1 | 72 | 82 | 8550 | 9180 | |||
| 40STD-FBM1110WS4 | 731 | 208 | 130 | 25 37.5 | 204 | 6″ | 148 | 1 | 52 | 6” | 126 | 1 | 64 | 82 | 4370 | 4950 | |
| 40STD-FBM1220WS4 | 800 | 227 | 140 | 213 8" | 162 | 1 | 52 | 8" | 138 | 1 | 64 | 82 | 5200 | 5470 | |||
| 40STD-FBM1380WS4 | 898 | 255 | 156 | 0 50 62.5 75 87.5 100 | 8″ | 181 | 1 | 8″ | 154 | 1 | 65 | 83 | 5450 | 5740 | |||
| 40STD-FBM1600WS4 | 1032 | 293 | 238 272 | 8" | 208 | 1 | 53 55 | 8 | 177 1 | 68 | 83 | 5630 | 6180 | ||||
| 40STD-FBM1880WS4 | 1230 | 350 | 180 | 340 | 8″ | 248 | 1 | 64 | 84 | 9450 | 10400 | ||||||
| 40STD-FBM2120WS4 | 1438 | 212 242 | 383 | 1 | 8" 10" | 212 247 | 1 1 | 80 82 | 84 | 9610 | 11600 | ||||||
| 409 | 280 | 476 | 10" 10″ | 289 331 | 1 | 64 65 | 10″ | 283 | 1 | 83 | 85 12190 | 13300 | |||||
| 40STD-FBM2580WS4 | 1646 | 468 | 621 | 12" | 420 | 10" | 95 | 86 | 15890 | 17910 | |||||||
| 40STD-FBM3040WS4 | 2094 | 595 | 348 | 1 | 80 | 360 | 1 | ||||||||||
| 40STD-FBM3480WS4 | 2342 | 666 | 384 | 714 | 14” | 469 | 1 | 81 | 12″ | 403 | 1 | 96 | 87 | 16720 18960 | |||
Screw Type Air-cooled Explosion-proof Chiller Technical Parameters(R22)
| Model | ||||||||||||||
| 40STE-B110AS4 | 113 | 36 | 0,66,100 | 30 | 40 | 2.0×2 | 2-1/2″ | 19 1 | 28 | 68 | 1160 | 1270 | ||
| 40STE-B160AS4 | 160 | 50 | 42 | 57 | 1.2×4 | 3″ | 28 | 1 | 33 | 68 1730 | 1920 | |||
| 40T-81A4 | 2422 | 0 50 75 100 | 8085 | 2.0×4 | 333 | 11 | 485 | 6868 | 300 | |||||
| 6574 | 568 | 743 | 3030 | |||||||||||
| 40STE-B280AS4 | 297 | 86 | 78 | 121 | 2.0×6 | 4" | 51 | 1 | 61 72 | 2750 | 3020 | |||
| 40STE-B310AS4 | 319 | 93 | 84 | 121 | 2.0×6 | 4 | 55 | 1 | 64 72 | 2930 | 3240 | |||
| 40STE-B340AS4 | 347 | 103 | 93 | 161 | 2.0×8 | 4" 60 | 1 | 66 | 72 | 3160 | 3450 | |||
| 40STE-B380AD4 | 397 | 120 | 0 25 37.5 505 75 87.5 100 | 104 | 161 | 2.0×8 | 5" | 68 1 | 68 | 73 | 4430 | 4750 | ||
| 40STE-B420AD4 | 428 | 130 | 112 | 161 | 2.0×8 | 5" 74 | 1 | 68 | 73 | 4550 | 4970 | |||
| 40STE-B480AD4 | 504 | 148 | 136 | 170 | 1.2×12 | 5" 87 | 1 | 70 | 73 | 5340 | 5800 | |||
| 40STE-B560AD4 | 594 | 172 | 142 | 241 | 2.0×12 4" | *2 102 | 1 | 70 | 75 | 5500 | 6040 | |||
| 40STE-B620AD4 | 638 | 186 | 156 | 241 | 2.0×12 4" | *2 110 | 1 | 72 | 75 | 5860 | 6480 | |||
Screw Type Air-cooled Explosion-proof Chiller Technical Parameters(R134a)
| Model | |||||||||||||||
| 40STE-BM110AS4 | 75 | 23 | 0,66,100 | 30 | 28 | 2.0×2 | 2-1/2" | 13 | 1 | 28 | 68 | 1160 | 1270 | ||
| 40STE-BM160AS4 | 107 | 32 | 0 50 75 100 | 42 | 40 | 2.0×2 | 3″ | 18 | 1 | 33 | 68 | 1730 | 1920 | ||
| 40STE-BM210AS4 | 143 | 43 | 56 | 80 | 2.0×4 | 3" | 25 | 1 | 48 | 68 | 2590 | 2810 | |||
| 40STE-BM240AS4 | 169 | 49 | 68 | 80 | 2.0×4 | 3″ | 29 | 1 | 55 | 68 | 2670 | 2900 | |||
| 40STE-BM280AS4 | 195 | 56 | 78 | 80 | 2.0×4 | 4" | 34 | 1 | 61 | 72 | 2750 | 3020 | |||
| 40STE-BM310AS4 | 217 | 60 | 84 | 85 | 1.2×6 | 4″ | 37 | 1 | 64 | 72 | 2930 | 3240 | |||
| 40STE-BM340AS4 | 236 | 68 | 93 | 121 | 2.0×6 4" | 41 | 1 | 66 | 72 3160 | 3450 | |||||
| 40STE-BM380AD4 | 277 | 83 | 0 25 37.5 505 75 | 104 | 121 | 2.0×6 | 5″ | 48 | 1 | 68 | 73 | 4430 | 4750 | ||
| 40STE-BM420AD4 | 286 | 86 | 112 | 114 | 1.2×8 | 5" | 49 | 1 | 68 | 73 | 4550 | 4970 | |||
| 40STE-BM480AD4 | 338 | 98 | 136 | 161 | 2.0×8 | 5″ | 58 | 1 | 70 | 73 | 5340 | 5800 | |||
| 40STE-BM560AD4 | 390 | 112 | 142 | 161 | 2.0×8 | 4" *2 | 67 | 1 | 70 | 75 | 5500 | 6040 | |||
| 40STE-BM620AD4 | 434 | 120 | 87.5 100 | 156 | 170 | 1.2×12 | 4″ *2 | 75 | 1 | 72 | 75 | 5860 | 6480 | ||
H.Stars (Guangzhou) Refrigerating Equipment Group Ltd.
Address:No.1 Guoyuan 4th Road,Guangzhou Economic& Technological Development Zone,
HuangPu District,Guangzhou, China Zip Code 510530
Email:sales@hstars.com.cn
Tel:+862062266755 ext.886
Fax:+862082266081
Website: www.hstarschiller.com
Twitter:twitter.com/HStarsGroup
Facebook:www.facebook.com/Hstarsgroup
Linkedln: www.linkedin.com/company/hstarsgroup
Instagram: www.instagram.com/hstars_chiller_maker