Santak Castle Series UPS
CASTLE 3C3 HD
20-200kVA
2 | CASTLE 3C3 HD
CASTLE 3C3 HD 20-200K
3C3 HD UPS is the new generation
three phase tower UPS, which
adopts the most advanced power
electronics and digital signal
control and protection technology.
It performs higher efficiency,
higher performance, and more
convenient operation, and can
provide users with high quality
power supply guarantee in various
industries.
Typical application
environment
• Small and medium-sized data
centers
• Computer data room
• Automation control system
• Transportation
• Banking, Finance
• Communication industry, 5G
• Production and manufacturing
Product features
• Adopt the new generation of IGBT and optimized three-level inverter
topology, with online efficiency up to 96% and ESS mode efficiency up
to 99%.
• Output power factor 1.0.
• Internal modular design, MTTR<30 minutes.
• High power density, save more than 50% footprint.
• Intelligent battery management function to extend battery life cycle.
• 5\" color touch screen for easy operation.
• Support lead-acid batteries and lithium batteries.
• Parallel UPS units up to 4, support common battery @2 UPS parallel.
• Support battery cold start.
Power range: 20/30/40/60/80/100/120/160/200kVA
Topology: Advanced three-level inverter, high-frequency IGBT conversion/
inversion technology
Input and output: 220V/380V three-phase four-wire
Frequency: 50/60 Hz
CASTLE 3C3 HD | 3
• ESS mode can provide up to 99% system efficiency, significantly reducing UPS power consumption and
cooling power consumption.
• In ESS mode, UPS built-in filter protection devices can still provide surge protection to ensure high-quality
power output.
• 3C3 HD can intelligently switch between ESS mode and double conversion mode automatically according to
the quality of the power grid. The typical switching time is only 2-4ms.
• In ESS mode, the reliability of key components is further improved and the service life is longer.
3C3 HD 20-200K UPS efficiency is up to 96% at online double conversion mode and 99% at ESS mode.
Extra Low TCO (Total Cost of Ownership)
330 690
975
600
850
1600
Model Width
(mm)
Depth
(mm)
Height
(mm)
Footprint
(m2)
Volumn
(m3)
40kVA
3C3 HD 330 668 521 0.21 0.05
Product A 440 750 1600 0.33 0.53
Product B 320 840 867 0.27 0.23
80kVA
3C3 HD 330 690 975 0.23 0.22
Product A 600 850 1600 0.51 0.82
Product B 450 840 1400 0.38 0.53
ESS mode
Typical load area
20%
95.5%
96.0%
96.5%
97.0%
97.5%
98.0%
98.5%
99.0%
99.5%
40% 60% 80% 100%
Double conversion mode
Smaller size, saving space in
computer room
The 3C3 HD adopts innovative modular design, optimizes the design
and layout of rectifiers, inverters and other components. On the premise
of ensuring reliability, the volume and weight of the product are greatly
reduced, which greatly saves the computer room space and improves the
utilization rate of the computer room. Compared to current mainstream
products in the market, the 3C3 HD saves 50% in footprint space and 90%
in volume.
4 | CASTLE 3C3 HD
load load load load
Output wiring
board
Mains input wiring board
Safe and reliable. Suitable for various application environments
DUSTPROOF DESIGN
Santak 3C3 HD has a dust filter to isolate dust from the outside of UPS, improving the adaptability to the harsh
environments. At the same time, the internal layout and airflow distribution are optimized, which greatly reduces
the dust accumulation.
• Dust filter complying with American fire protection standard UL94 and dust filter standard UL900.
• Easy to disassemble and clean. Low maintenance cost.
CAPACITORS HEALTH MONITORING
Santak 3C3 HD innovatively adopts a filter capacitor health monitoring
function, through real-time temperature detection of the internal
capacitor, monitors the health status of the capacitor, provides early
warning information before the capacitor is damaged, avoids the
occurrence of failure, and greatly guarantees the stability and reliability of
power for critical loads.
• Use temperature sensors to detect real-time temperature of all input
and output filtering capacitors.
• Fully automatic intelligent judgment of capacitor life, providing warning
information before the expiration of capacitor life to avoid faults.
• The protection measures will be activated as soon as possible in case of
abnormal capacitor faults , avoiding further expansion of faults.
PCBA COATING
Short circuit caused by corrosion of PCBA is one of the important
reasons for failure of UPS, especially in coastal cities. Santak 3C3 HD uses
advanced intelligent PCBA coating technology to further improve the salt
spray and corrosion resistance of the product.
• Full-automatic coating process to avoid manual operation error and
ensure coating precision and consistency.
• Blue-ray detection technology is used to ensure the coating quality.
INTELLIGENT PARALLEL
REDUNDANCY
The Santak 3C3 HD has built-in
synchronous CAN communication,
and no need to install a parallel
card during parallel operation. It
ensures output synchronous and
load balance of each UPS in the
parallel system, and ensures the
reliability and redundancy of the
parallel system.
• Point-to-point control, no
\"master-slave\" dependency
parallel control.
• No traditional load sharing lines.
• Eliminate single point of failure
in the system.
• Fast fault detection and
breakaway technology.
• Reliability is further enhanced.
CASTLE 3C3 HD | 5
• The first two-stage charging
mode ensures that the battery is
fully charged.
• The third stage rest mode make
the battery in the state of natural
discharge. UPS detects the
battery voltage in real time, and
automatically starts the charger
to enter a new charging cycle
again when the battery voltage
drops to the setting value.
• Intelligent rest mode can extend
battery life by up to 50%.
SANTAK INTELLIGENT BATTERY MANAGEMENT
3C3 HD adopts Santak intelligent battery management technology. In addition to the traditional two-stage
charging, it also has an intelligent rest mode to avoid the aging effect of the battery due to long-term floating
charge. This technology can also accurately predict the working state of the battery, detect potential discharge
faults in advance and give a warning.
Charge mode
Battery test 1
35 sec
24 hours
100 hours max 48 hours - 96 hours
2.1
2.3
28 days
< 10 days
Battery test 2
45 sec
float mode Rest mode
Volts per cells
Convenient operation and maintenance
Santak 3C3 HD adopts a 5” colorful touch screen with 3 color LED indicators, which is convenient for users to
check UPS running status and operate the UPS.
MENU ITEMS
Meters: Display the measurements of the system or critical load.
Control: Access various system control screens.
Statistics: Access and view the specific operating values of the system. Such operations shall be performed by
Eaton service engineers only.
Log: Access the system logs, including alerts, notices and commands.
Info: Display the UPS and HMI information.
Settings: Access various screen control variables for system operation.
1
2
3
4
UPS status area
Energy flow diagram
Meters data area
More Menu
1
2
3
4
6 | CASTLE 3C3 HD
3C3 HD 20-200K Technical Data
Model 3C3 HD-20K 3C3 HD-30K 3C3 HD-40K 3C3 HD-60K 3C3 HD-80K
Power rating 20KVA/20KW 30KVA/30KW 40KVA/40KW 60KVA/60KW 80KVA/80KW
Input
Wiring Wiring Three phase+Neutral+Ground
Mains voltage range 201 ~ 478Vac (L-L); 116 ~ 276Vac (L-N)
Bypass voltage range 338 ~ 458Vac (L-L); 195 ~ 264Vac (L-N)
Frequency 50/60Hz
Frequency range 42 - 70Hz
Power factor ≥ 0.99
THDi <2% linear load; <5% non-linear load
Output
Voltage 230/400Vac default (220/380V,240/415V optional)
Votlage regulation <1% @ steady state
Power factor 1
Overload
102 ~ 110%, 60mins
111 ~ 125%, 10mins
126 ~ 150%, 1min
parallel Up to 4 units
Efficiency
Online mode Up to 96%
ECO mode Up to 99%
Battery
Battery Voltage 320V~607V, default 432V (32~44 Blocks, default 36 blocks)
Max charge current 25A 38A 50A 76A 100A
Environment
Ambient temperature 0-40°C
Storage temperature –15 ~ +55°C
Ambient humidity 5 - 95 %
Altitude No derating < 1000m
Physical
Diamension (W*D*H) 330*668*521mm 330*690*975mm
Net Weight 41kg 45kg 45kg 90kg 90kg
Gross weight 50kg 55kg 55kg 131kg 131kg
Standard Safty IEC 62040
CASTLE 3C3 HD | 7
3C3 HD 20-200K Technical Data
Model 3C3HD-100K 3C3HD-120K 3C3HD-160K 3C3HD-200K
Power rating 100kVA/100kW 120kVA/120kW 160kVA/160kW 200kVA/200kW
Input
Wiring Wiring Three phase+Neutral+Ground
Mains voltage range 201 ~ 478Vac (L-L); 116 ~ 276Vac (L-N)
Bypass voltage range 338 ~ 458Vac (L-L); 195 ~ 264Vac (L-N)
Frequency 50/60Hz
Frequency range 42 - 70Hz
Power factor ≥ 0.99
THDi <3% linear load; <5% non-linear load
Output
Voltage 230/400Vac default (220/380V,240/415V optional)
Votlage regulation <1% @ steady state
Power factor 1
Overload
102 ~ 110%, 60mins
111 ~ 125%, 10mins
126 ~ 150%, 1min
parallel Up to 4 units
Efficiency
Online mode Up to 96%
ECO mode Up to 99%
Battery
Battery Voltage 320V~607V, default 432V (32~44 Blocks, default 36 blocks)
Max charge current 100A 120A 160A 200A
Environment
Ambient temperature 0-40°C
Storage temperature –15 ~ +55°C
Ambient humidity 5 - 95 %
Altitude No derating < 1000m
Physical
Diamension (W*D*H) 500*850*1230 550*850*1600
Net Weight 149kg 149kg 245kg 270kg
Gross weight 162kg 162kg 270kg 295kg
Standard Safty IEC 62040
SANTAK ELECTRONIC (SHENZHEN) CO., LTD.
Website: www.santak.com
July. 2026
Shenzhen, P.R. China
Address: No. 8 Baoshi Road, Baoan
District, Shenzhen, 518101
Tel: 0086 755 27572666
Fax: 0086 755 27572730 (27572480)
Email: santakexport@santak.com