COMPREHENSIVE SELECTIONMANUAL
COMPANY PROFILE
Scale,show strength!
JOYELEC companybeestablished in2011year,which isa companylocated inLiushiWenzhoucity,China.JOYELEC companybecombinedbyexportcompany&ingection moldingworkshop&metal stampingworkshop&product manufacture company,whichmainly focus on low-voltage electric products,such asmcb、mccb、contactor、 relay、switch、pushbutton、distributionbox、industry socket and plug、terminal etc.
Withourhighquality,competitiveprice,fastdelivery timeand efficient service,wearedevelopingalwayswith customersallovertheworld.Currentlywehavemore than 100 employeesand engineers.Wealso candevelopnew productsmould and manufactureaccordingto customers special requirement.Weare looking forward to your inquiries for future cooperation.
WORKSHOP EQUIPMENT
Quality comes from the improvementof everydetail
Thecompany has produces the products strictly in compliancewith nationalstandardsand internationalstandards,controlstheprocedures fromrawmaterialtothefinishedproductscompletely.Inaddition,the company set down the quality policy "Regard thecustomerdemand as thecenter,production managementas foundation,improve the quality systemcontinuously,improve user satisfactionwith the products".
Thecompanyemploys firstclass productionequipmentand manufacturingengineering,paysattentions to new products developingandmanpowertraining,now,she hasownedacomplete setofresearchingandmanufacturingtechnologyforsoftstarter products.
Insistingon the goal of high qualityand highaccuracy,JOYELEC peoplewill trytheirbestto providecustomersall over theworld with themost excellent products,and work hard to sharea largermarket in thecompetitive electricalfield.
JOYELEC ⑧
QUALIFICATION CERTIFICATE
Regard product quality as life
Aroundcountlessachievements,wecherishmore thanbefore Butwe can'tsaitisfy notdare toslacken our efforts for this Becausewe know— Honor is yesterday's praise Our pursuing is endless.
OurVision
Tobeaglobal leader in laser tubeprocessing!
OurMission
Focusing on the R&D and productionof laser pipe cutting machinesforglobalcustomers.Providing intelligent comprehensivesolutionsforlasertube processing!
OurValues
Based on customer needs,togetherwith continuous innovation, we hope fora win-win situation with customer, employeesandenterprises!
JOYELEC ⑧
PRODUCT CATALOGUE Selection,high qualityproducts!
MiniatureCircuitBreaker Page 01\~18
5
Contactor&Relay&DOL Page40\~50
记
EarthLeakageCircuitBreaker Page19\~26
6
Meter Page 51\~55
3
MouldedCaseCircuitBreaker Page27\~37
7
IndustryPlug&Socket Page 56\~58
OtherElectrical Page38\~39
8
NylonCableTies Page59
JOYELEC TECHNOLOGY www.joyelec.com
QYB-633KA TO 4.5KA Miniature Circuit Breaker
Compliant standards IEC/EN60898-1
Major function
Overload protection,short circuit protection,positive isolation
Technical parameters
0 Rated current:1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A,50A,63A;
0 Ratedvoltage:220V\~/230V\~/240V\~(1P,1P+N,2P),380V\~/400V\~/415V\~(2\~4P,3P+N);
0 Frequency.50/60Hz;
0 Thermal magnetic release:B,C,D;
0 Numberof poles:1P,1P+N(Nonright),2P,3P,3P+N(Nonright),4P;
0 Mechanical life:200o0 cycles;
0 Electrical life:10000 cycles;
0 Rated short-circuitbreaking capacity(lcn):3000A,4500A(2P,220V/230V/240V);
0 Short-circuit breaking capacity (lcs):3000A,4500A(2P,220V/230V/240V);
0 Rated insulationvoltage Ui:500V 0 Rated impulse withstand voltage (Uimp):4kV;
0 Power consumption oneach pole of the circuit breaker:see Table 1.
Temperaturederatingsee table2
| Rated current In (A) | Maximum powerconsumptionper pole (W) |
| 1~10 | 3 |
| 16 | 3.5 |
| 20~25 | 4.5 |
| 32 | 6 |
| 40 | 7.5 |
| 50 | 9 |
| 63 | 13 |
| Amientemurratur(C) | -35 | -20 | -10 | 0 | 10 | 20 | 30 | 40 50 | 60 | 70 |
| 1~6 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 10~25 | 1.27 | 1.24 | 1.19 | 1.13 | 1.07 1.02 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 32~40 | 1.27 | 1.24 | 1.19 | 1.13 | 1.08 1.04 | 1 | 0.97 | 0.92 | 0.88 | 0.83 |
| 50~63 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
QYB-125 Miniature Circuit Breaker
Compliant standards IEC/EN60947-2
Major function
Overload protection,shortcircuit protection,positive isolation
Compliant certification CE
Technical parameters
0 Ratedcurrent:63A,80A,100(1P,2P,3P,4P),125A(1P,2P);
0 Rated voltage:230V\~(1P),400V\~(2P,3P,4P);
0 Frequency. 50/60Hz 0 Thermal magnetic release:C:8ln,D:12ln 0 Numberof poles:1P,2P,3P,4P;
0 Mechanical life:200o0 cycles;
0 (20 Electrical life:6000cycles(In≤100A);4000cycles (In>100A);
0 (20 Rated short-circuit breaking capacity(lcu):10kA;
0 (204号 Short-circuit breaking capacity(lcs):10Ka;
0 Rated impulse withstand voltage(Uimp):4kV;
Technical parameter
| 1P.0.52 | 2P.0.74 | 3P.1.40 | 4P.40 | |
| L(mm) | 27..20 | 54.20 | 81.20 | 108.20 |
| H(mm) | 75.5 | 78.5 | 78.5 | 78.5 |
QYB DC Miniature Circuit Breaker
Application
QYB-63DC MCBsupplementaryprotectorsaredesigned toprovide overcurrent protection within appliancesorelectrical equipment,whereabranchcircuitprotection isalreadyprotectionornotrequired Devicesare designed for direct current (DC) control circuit applications.
Technical parameters
| QYB-63SeriesCircuit Breaker | QYB-63DC | |
| FrameDegree Rated Current(A) | 63 | |
| Pole | 1P,2P,3P,4P | |
| Rated Operating Voltage(VDC) | DC12V-DC1200V | |
| Rated Current In (A) | 1-63A | |
| Rated Insulation VoltageUi(VDC) | 1200VDC | |
| Rated ImpactVoltageUimp(KV) | 4 | |
| Ultimate BreakingCapacity Icu (KA) | 6 | |
| RunBreaking Capacity Ics (%lcu) | 75% | |
| Curve Type | C | |
| TripType | Thermal-magnetic | |
| Mechanical | Actual Average Value | 20000 |
| Standard | 8500 | |
| Electric | Actual Average Value | 2500 |
| Standard | 1500 | |
Application
QYB-63DC MCB high breaking capacity circuit breaker is specially forsolar PVsystem.Thecurrent is form63Ato125Aand voltage upto100oVDC.Standardaccordingto IEC/EN60947-2.
Technical parameters
| QYB-63SeriesCircuit Breaker | QYB-125 | |||
| Rated Current | 63,80,100,125A | |||
| Rated Voltage | 250VDC/550VDC/750VDC/1000VDC | |||
| Electrical Life | 6000 Times | |||
| Mechanical Life | 20000 times(C.O.) | |||
| No. of Pole | 1P,2P,3P,4P | |||
| Weight(G) | 1P | 2P | 3P | 4P |
| 180 | 360 | 540 | 720 | |
QYB1-63 4.5KA TO 6KA Miniature Circuit Breaker
Application
QYB1-63 high breaking miniature circuit breaker has the features of structureadvanced,performance reliable,breakingcapacityhigh,appearanceelegantand itsshellandpartsaremadeof material with impact resistance,strongflame-retardant feature
Itissuitabletopowersystemof 50or60frequency,Ue40oVandbelow,Ui63Aandbelow. It ismainlyappliedatofficebuilding,residence,forlighting,powerdistributionandoverloadandshort circuitprotectionofequipment.Normaly,italsocanbeusedasthenotfrequent transferof powersystem. It conformsto the standards IEC60898 and GB10963.1.
Features
0 Rated voltage:230/400VAC
0 frequency: 50/60Hz
0 Ratedcurrent:1,2,3,4,5,6,10,16,20,25,32,40,5
0 1/2/3/4 poles optional
0 Mechniacal life:20,0ootimes
0 Flame-redardant:PA66 nylonmaterial
0 Protection degree: IP20
0 Withover load/shortcircuit protection
0 Standard: IEC60898
0 Enduring tem:30℃
0 Breaking Capacity:6KA
0 Lighting/Motor protection optional
Technical parameters
| Rated voltage(V) | Poles | Rated current (A) | Ratedshort circuit breakingcapacity | |
| Tettst breaking capacity(kA) | Powerfactor | |||
| 230 | 1.2 | 6,10,16,20 | 6 | 0.65~0.7 |
| 230/400 | 1,2 | 25,32 | 6 | |
| 400 | 2,3,4 | 40 | 6 | |
| 230 | 1,2 | 50,63 | 6 | 0.75-0.8 |
| 230/400 | 1,2 | 6 | ||
| 400 | 2,3,4 | 6 | ||
Remark:
1.Mechanical life:20ooo times (off-on)
2.Heat resistance:category2 (temperature55C,relative humidity95%)
3.Wiring is terminal withclamp,cable dia: 2 5mm ^ { 2 }
| Test current(A) | Rated current(A) | Requested time | Result | Start station | Remark |
| 1.13ln | all | t≥1h | Donp | 1.13ln | |
| 1.45ln | all | T | trip | 1.13ln | reqCurentalscestdst in s |
| 2.55ln | In≤32A | 1s| 1.13ln | Auxiliaryswitchclosed power ison | | |
| 2.55ln | In>32A | 1s| 1.13ln | Auxiryswitchclosed | | |
| 5ln(C mode) | all | t≥0.1s | 1.13ln | Auxilary wftchciosed | |
| 10ln(C mode) | all | t | 1.13ln | Auxiryswitchclosed | |
| 10ln(C mode) | all | t≥0.1s | 1.13ln | Auliryswtchclosed | |
| 14ln(C mode) | all | t | 1.13ln | Auxiry witch closd |
QYB2-63 4.5KA TO 6KA Miniature Circuit Breaker
Compliant standards IEC/EN60947-2
Major function
Overload protection,short circuit protection,positive isolation
Technical parameters
0 Rated CUrrent:1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A,50A,63A;
0 Ratedvoltage:220V\~/230V\~/240V\~(1P,1P+N,2P),380V\~/400V\~/415V\~(2\~4P,3P+N);
0 Frequency:50/60Hz;
0 Thermal magnetic release: B, C,D;
0 Numberof poles:1P,1P+N(Nonright),2P,3P,3P+N(Nonright),4P;
0 Mechanical life:20oo0 cycles;
0 Electricalife:10000cycles;
0 Rated short-circuit breakingcapacity(lcn):3000A,4500A(2P,220V/230V/240V);
0 Short-circuit breakingcapacity (lcs):3000A,4500A(2P,220V/230V/240V);
0 Rated insulation voltage Ui: 500V 0 Rated impulse withstand voltage (Uimp):4kV;
Power consumption on each pole of the circuit breaker:see Table 1.
| Ratedcurrent In (A) | Maximum powerconsumption per pole (W) |
| 1~10 | 3 |
| 16 | 3.5 |
| 20~25 | 4.5 |
| 32 | 6 |
| 40 | 7.5 |
| 50 | 9 |
| 63 | 13 |
| Ambienttemperature('℃) Ratedcurrent In (A) | -35 | -20 | -10 | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 |
| 1~6 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 10~25 | 1.27 | 1.24 | 1.19 | 1.13 | 1.07 | 1.02 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 32~40 | 1.27 | 1.24 | 1.19 | 1.13 | 1.08 | 1.04 | 1 | 0.97 | 0.92 | 0.88 | 0.83 |
| 50~63 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
QYB2-125 Miniature Circuit Breaker
Compliant standards IEC/EN60947-2
Major function
Overload protection,short circuit protection,positive isolation
Compliant certification CE
Technical parameters
0 Rated current:63A,80A,100(1P,2P,3P,4P),125A(1P,2P);
0 Rated voltage:230V\~(1P),400V\~(2P,3P,4P);
0 Frequency.50/60Hz 0 Thermal magnetic release:C:8ln,D:12ln 0 Numberof poles:1P,2P,3P,4P;
0 Mechanical life: 200o0 cycles;
0 (204号 Electrical life:6000cycles(In≤100A);4000cycles(In>100A);
0 Rated short-circuit breaking capacity(lcu):10kA;
0 Short-circuit breaking capacity(lcs):10Ka;
0 Rated impulse withstand voltage(Uimp):4kV;
Technical parameter
| 1P | 2P | 3p | 4P | |
| L(mm) | -0.52 27.0.5 | 548.74 | 81.40 | 108..40 |
| H(mm) | 75.5.20 | 78.5.20 | 78.5.1.20 | 78.5.20 |
QYB2DC Miniature Circuit Breaker
Application
QYB2-63 DC MCB supplementary protectorsare designed to provide overcurrent protection within appliances or electrical equipment,where a branch circuit protection isalready protection or not required. Devicesare designed fordirect current (DC) control circuitapplications.
Technical parameters
| QYB2-63SeriesCircuit Breaker | QYB2-63DC | ||
| Frame Degree Rated Current(A) | 63 | ||
| Pole | 1P,2P,3P,4P | ||
| Rated Operating Voltage(VDC) | DC12V-DC1200V | ||
| RatedCurrent In (A) | 1-63A | ||
| Rated Insulation Voltage Ui (VDC) | 1200VDC | ||
| Rated ImpactVoltageUimp (KV) | 4 | ||
| UltimateBreakingCapacitylcu (KA) | 6 | ||
| RunBreaking Capacity Ics (%lcu) | 75% | ||
| Curve Type | C | ||
| TripType | Thermal-magnetic | ||
| Mechanical | Actual average value | 20000 | |
| Standard | 8500 | ||
| Electric | Actual average value | ||
| Standard | 2500 | 1500 | |
Application
QYB2-125DC MCB high breaking capacity circuit breaker isspeciallyforsolar PVsystem.The current is form63A to125Aand voltageupto100oVDC.Standardaccording to IEC/EN60947-2.
Technical parameters
| QYB2-125SeriesCircuitBreaker | QYB2-125DC | |||
| Rated Current | 63,80,100,125A | |||
| Rated Voltage | 250VDC/550VDC/750VDC/1000VDC | |||
| Electrical Life | 6000 Times | |||
| Mechanical Life | 20000times(C.O.) | |||
| No. of Pole | 1P,2P,3P,4P | |||
| Weight(G) | 1P | 2P | 3P | 4P |
| 180 | 360 | 540 | 720 | |
QYB3-63 6KA TO 1OKA Miniature Circuit Breaker
Compliant standards IEC/EN60898-1
Major function
Overload protection,short circuit protection,positive isolation
Technical parameters
0 Rated current:1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A,50A,63A;
0 Ratedvoltage:220V\~/230V\~/240V\~(1P,1P+N,2P),380V\~/400V\~/415V\~(2\~4P,3P+N);
0 Frequency.50/60Hz;
0 Thermal magnetic release:B,C,D;
0 Numberof poles:1P,1P+N(Nonright),2P,3P,3P+N(Nonright),4P;
0 Mechanical life:200o0 cycles;
0 Electrical life:10000 cycles;
0 Rated short-circuitbreaking capacity(lcn):3000A,4500A(2P,220V/230V/240V);
0 Short-circuit breaking capacity (lcs):3000A,4500A(2P,220V/230V/240V);
0 Rated insulationvoltage Ui:500V 0 Rated impulse withstand voltage (Uimp):4kV;
0 Power consumption on each pole of the circuit breaker:see Table 1.
Temperature derating see table2
| Rated current In (A) | Maximum powerconsumptionper pole (W) |
| 1~10 | 3 |
| 16 | 3.5 |
| 20~25 | 4.5 |
| 32 | 6 |
| 40 | 7.5 |
| 50 | 9 |
| 63 | 13 |
| Amientemurratur(C) | -35 | -20 | -10 | 0 | 10 | 20 | 30 | 40 50 | 60 | 70 |
| 1~6 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 10~25 | 1.27 | 1.24 | 1.19 | 1.13 | 1.07 1.02 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 32~40 | 1.27 | 1.24 | 1.19 | 1.13 | 1.08 1.04 | 1 | 0.97 | 0.92 | 0.88 | 0.83 |
| 50-63 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
QYB3-1OoAC 1OKA Miniature Circuit Breaker
General
Certificates:CE
Standard: IEC60947-2;
Ratedvoltageupto1oooV,Ratedcurrentupto63A; Protection of circuits against overload currents;
Protection of circuitsagainst short-circuitcurrents; QYB3-10oACcircuit-breakersare used in
communication systems and PVAC systems.
Technical data
Ambienttemperature:-35C\~+70℃
Theatmosphere condition:≤95%
Pollution degree:ⅡI
RateCurrentIn:6A,1A,13A,16A,2A,25A,32A,4A,5A,A
Numberof poles:1P,2P,3P,4P
Tripping curves:C Type,(7\~10)ln
| Rated current(A) | -35℃ | -30℃ | -20℃ | -10℃ | 0℃ | 10℃ | 20℃ | 30℃ | 40℃ | 50 | 60 | 70 |
| 1 | 1.3 | 1.26 | 1.23 | 1.19 | 1.15 | 1.11 | 1.05 | 1 | 0.96 | 0.93 | 0.88 | 0.83 |
| 2 | 2.6 | 2.52 | 2.46 | 2.38 | 2.28 | 2.2 | 2.08 | 2 | 1.91 | 1.86 | 1.76 | 1.66 |
| 3 | 3.9 | 3.78 | 3.69 | 3.57 | 3.42 | 3.3 | 3.12 | 3 | 2.88 | 2.79 | 2.64 | 2.49 |
| 4 | 5.2 | 5.04 | 4.92 | 4.76 | 4.56 | 4.4 | 4.16 | 4 | 3.84 | 3.76 | 3.52 | 3.32 |
| 6 | 7.8 | 7.56 | 7.38 | 7.14 | 6.84 | 6.6 | 6.24 | 6 | 5.76 | 5.64 | 5.28 | 4.98 |
| 10 | 13.2 | 12.7 | 12.5 | 12 | 11.5 | 11.1 | 10.6 | 10 | 9.6 | 9.3 | 8.9 | 8.4 |
| 13 | 17.16 | 16.51 | 16.25 | 15.6 | 14.95 | 14.43 | 13.78 | 13 | 12.48 | 12.09 | 11.57 | 10.91 |
| 16 | 21.1220.48 | 20 | 19.2 | 18.4 | 17.76 | 16.96 | 16 | 15.36 | 14.88 | 14.24 | 13.44 | |
| 20 | 26.4 | 25.6 | 25 | 24 | 23 | 22.2 | 21.2 | 20 | 19.2 | 18.6 | 17.8 | 16.8 |
| 25 | 33 | 32 | 31.25 | 30 | 28.75 | 27.75 | 26.5 | 25 | 24 | 23.25 | 22.25 | 21 |
| 32 | 42.5641.28 | 40 | 38.7237.1235.52 | 33.93 | 32 | 30.72 | 29.7628.1626.88 | |||||
| 40 | 53.2 | 51.2 | 50 | 48 | 46.4 | 44.8 | 42.4 | 40 | 38.4 | 37.2 | 35.6 | 33.6 |
| 50 | 67 | 65.5 | 63 | 60.5 | 58 | 56 | 53 | 50 | 48 | 46.5 | 44 | 41.5 |
| 63 | 83.79 | 81.9 | 80.01 | 76.86 | 73.71 | 70.56 | 66.78 | 63 | 60.48 | 58.9 | 55.4452.29 |
Dimensions and installation sizes(mm)
QYB3-1OoDC 1OKA Miniature Circuit Breaker
Application
QYB3-100DCMCB supplementaryprotectorsare designed toprovide overcurrentprotectionwithin appliancesor electrical equipment,whereabranch circuit protection isalreadyprotection or not required. Devices are designed for direct current (DC) control circuit applications.
Technical parameters
| QYB3-100Series Circuit Breaker | QYB3-100DC | |||
| Rated Current | 63,80,100A | |||
| Rated Voltage | 250VDC/550VDC/750VDC/1000VDC | |||
| Electrical Life | 6000 Times | |||
| Mechanical Life | 20000times(C.O.) | |||
| No.of Pole | 1P,2P,3P,4P | |||
| Weight(G) | 1P | 2P | 3P | 4P |
| 180 | 360 | 540 | 720 | |
QYB3DCT 1OKA DC Miniature Circuit Breaker
General
0 Certificates: CE;
0 Standard:IEC/EN60947-2,RoHS; Ratedvoltage upto10ooV,Ratedcurrent up to63A;
△ Protection of circuitsagainst overload currents;
< Protectionofcircuitsagainstshort-circuit currents;
0 QYB3-63 DC circuit-breakers are used in
0 communication systems and PVDC systems.
Type designation
QYB3-DCT Direct Current Designed sequence number MCB Company code
Features
0 Excellent breaking capacity 0 Double connection function of lead wire and bus bar 0 Stored energy operation,fastclosing,longservice life 0 Convenient installation,disassembly 0 Contact on-off indication,higher secuity 0 Green environmental protection and energy saving
Operating conditions
0 Ambient temperature:-35C\~+70C(Refer to5.3) 0 The atmosphere condition:≤95% 0 Pollution degree:ll 0 Altitude:≤2000m(if exceed 2000m,Referto5.4)
Technical data
0 Classification
0 Rate Current In:1A,2A3A,4A6A,A, 16A,20A,25A,32A,40A,50A,6A Number of poles:1P,2P,4P
0 Tripping curves:C Type,(7\~1O)ln Parameters
0 Rated breaking capacity lcu
Wiring diagram description:
1P 2P 日 1 工 + m F==== + L L+
1.Positive \Theta Negative
2 . 1 + Load positive L-Load negative
3.Prohibit power reversed
4.Ratedvoltage:1P:250V2P:500V,4P:1000V 5.Strictly forbiddentoremove the fourpoles products of sealing plugwiring operation.
QHB4-63 6KA Miniature Circuit Breaker
General
Function
protectionof circuitsagainstshort-circuit currents,protectionofcircuitsagainst overload currents, switch,isolation.QHB4-63circuit-breakersareusedindomesticinstalation,aswellasincommercial and industry electrical distribution systems.
Selectiont
Technical dataof thenetworkatthepointconsidered:short-circuitcurrentat thecircuit-breaker installationpoint,whichmust alwaysbe less than the breakingcapacityof thisdevice,network normal voltage.Trippingcurves:
B curve (3-5ln)
protection forpeople andbig lengthcablesinTNandIT systems.
C curve (5-10ln)
protection for resistiveand inductive loadswith low inrush current.
D curve(10-14ln)
protection for circuitswhich supply loads with high inrush current at the circuit closing (LV/LVtransformers, breakdown lamps)
Approvalsandcertificates
Detailed information,please refer to Certificates Table on the last page.
Features
0 Ratedvoltage:230/400VAC
0 frequency:50/60Hz
0 Ratedcurrent:1,2,3,4,5,6,10,16,20,25,32,40,50,6A
0 1/2/3/4 polesoptional
0 Mechniacal life:20,0ootimes
0 Flame-redardant:PA66nylonmaterial
0 Protection degree: IP20
0 With over load/short circuit protection
0 Standard: IEC60898
0 Enduring tem:30℃
0 Breaking Capacity:6KA
0 Lighting/Motor protection optional
Dimensions and installation sizes(mm)
BTMiniature Circuit Breaker
Compliant standards IEC/EN60947-2
Major function
Overload protection,shortcircuit protection,positive isolation
Technical parameters
0 Rated CUrrent:1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A,50A,63A;
0 Ratedvoltage:220V\~/230V\~/240V\~(1P,1P+N,2P),380V\~/400V\~/415V\~(2\~4P,3P+N);
0 Frequency:50/60Hz;
0 Thermal magnetic release:B, C,D;
0 Numberof poles:1P,1P+N(Nonright),2P,3P,3P+N(Nonright),4P;
0 Mechanical life:20oo0 cycles;
0 Electricalife:10000cycles;
0 Rated short-circuit breakingcapacity(lcn):3000A,4500A(2P,220V/230V/240V);
0 Short-circuit breaking capacity (lcs):3000A,4500A(2P,220V/230V/240V);
0 Rated insulation voltage Ui: 500V 0 Rated impulse withstand voltage (Uimp):4kV;
Power consumption on each pole of the circuit breaker:see Table 1.
| Rated current In (A) | Maximum powerconsumption per pole (W) |
| 1~10 | 3 |
| 16 | 3.5 |
| 20~25 | 4.5 |
| 32 | 6 |
| 40 | 7.5 |
| 50 | 9 |
| 63 | 13 |
| Ambienttemperature(℃) Rated current In (A) | -35 | -20 | -10 | 0 | 10 | 20 | 30 | 40 | 50 | 60 | 70 |
| 1~6 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 10~25 | 1.27 | 1.24 | 1.19 | 1.13 | 1.07 | 1.02 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 32~40 | 1.27 | 1.24 | 1.19 | 1.13 | 1.08 | 1.04 | 1 | 0.97 | 0.92 | 0.88 | 0.83 |
| 50~63 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
IC6ON Miniature Circuit Breaker
Compliant standards IEC/EN60898-1
Major function Overload protection,short circuit protection,positive isolation
Technical parameters
0 Rated Current:1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A,50A,63A;
0 Ratedvoltage:220V\~/230V\~/240V\~(1P,1P+N,2P),380V\~/400V\~/415V\~(2\~4P,3P+N);
0 Frequency: 50/60Hz;
0 Thermal magnetic release:B,C,D;
0 Number of poles:1P,1P+N(Nonright),2P,3P,3P+N(Nonright),4P;
0 Mechanical life:200o0 cycles;
0 Electrical life:10000 cycles;
0 Rated short-circuit breaking capacity(lcn):3000A,4500A(2P,220V/230V/240V);
0 Short-circuit breaking capacity (lcs):3000A,4500A(2P,220V/230V/240V);
0 Rated insulationvoltage Ui:500V 0 Rated impulse withstand voltage (Uimp):4kV;
0 Power consumption on each pole of the circuit breaker:see Table 1.
Temperaturederatingsee table2
| Rated current In (A) | Maximum power consumption per pole (W) |
| 1~10 | 3 |
| 16 | 3.5 |
| 20~25 | 4.5 |
| 32 | 6 |
| 40 | 7.5 |
| 50 | 9 |
| 63 | 13 |
| Ambientemurrntuar("C) | -35 | -20 | -10 | 0 | 10 | 20 | 30 | 40 50 | 60 | 70 |
| 1-6 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 10~25 | 1.27 | 1.24 | 1.19 | 1.13 | 1.07 1.02 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 32~40 | 1.27 | 1.24 | 1.19 | 1.13 | 1.08 1.04 | 1 | 0.97 | 0.92 | 0.88 | 0.83 |
| 50~63 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
NC125 Miniature Circuit Breaker
Compliantstandards IEC/EN60898-1
Major function Overload protection,shortircuitprotection,positiveisolation
Technical parameters
0 Rated current:1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A,50A,63A;
0 Ratedvoltage:220V\~/230V\~/240V\~(1P,1P+N,2P),380V\~/400V\~/415V\~(2\~4P,3P+N);
0 Frequency.50/60Hz;
0 Thermal magnetic release:B,C,D;
0 Numberof poles:1P,1P+N(Nonright),2P,3P,3P+N(Nonright),4P;
0 Mechanical life:200o0 cycles;
0 Electrical life:10000 cycles;
0 Rated short-circuitbreaking capacity(lcn):3000A,4500A(2P,220V/230V/240V);
0 Short-circuit breaking capacity (lcs):3000A,4500A(2P,220V/230V/240V);
0 Rated insulationvoltage Ui:500V 0 Rated impulse withstand voltage (Uimp):4kV;
0 Powerconsumption on each pole of the circuit breaker:see Table1.
| Rated current In (A) | Maximum powerconsumptionper pole (W) |
| 1~10 | 3 |
| 16 | 3.5 |
| 20~25 | 4.5 |
| 32 | 6 |
| 40 | 7.5 |
| 50 | 9 |
| 63 | 13 |
Table 2
| Ambienttemperature(℃) Rated current(A) | -35 | -20 | -10 | 0 | 10 | 20 | 30 | 40 50 | 60 | 70 |
| 1~6 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 10~25 | 1.27 | 1.24 | 1.19 | 1.13 | 1.07 1.02 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 32~40 | 1.27 | 1.24 | 1.19 | 1.13 | 1.08 1.04 | 1 | 0.97 | 0.92 | 0.88 | 0.83 |
| 50~63 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
Dimensions and installation sizes(mm)
EZ9-63 Miniature Circuit Breaker
Compliant standards IEC/EN60898-1
Major function Overload protection,short circuit protection,positive isolation
Technical parameters
0 Rated current:1A,2A,3A,4A,6A,10A,16A,20A,25A,32A,40A,50A,63A;
0 Ratedvoltage:220V\~/230V\~/240V\~(1P,1P+N,2P),380V\~/400V\~/415V\~(2\~4P,3P+N);
0 Frequency: 50/60Hz;
0 Thermal magnetic release:B,C,D;
0 Number of poles:1P,1P+N(Nonright),2P,3P,3P+N(Nonright),4P;
0 Mechanical life:200o0 cycles;
0 Electrical life:10000 cycles;
0 Rated short-circuit breaking capacity(lcn):3000A,4500A(2P,220V/230V/240V);
0 Short-circuit breaking capacity(lcs):3000A,4500A(2P,220V/230V/240V);
0 Rated insulationvoltage Ui:500V 0 Rated impulse withstand voltage (Uimp):4kV;
0 Power consumption on each pole of the circuit breaker:see Table 1.
| Ratedcurrent In (A) | Maximum powerconsumptionper pole (W) |
| 1~10 | 3 |
| 16 | 3.5 |
| 20~25 | 4.5 |
| 32 | 6 |
| 40 | 7.5 |
| 50 | 9 |
| 63 | 13 |
Table 2
| Amintecuratur(C) | -35 | -20 | -10 | 0 | 10 | 20 | 30 | 40 | 50 60 | 70 |
| 1~6 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 | 1.03 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 10~25 | 1.27 | 1.24 | 1.19 | 1.13 | 1.07 1.02 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
| 32~40 | 1.27 | 1.24 | 1.19 | 1.13 | 1.08 1.04 | 1 | 0.97 | 0.92 | 0.88 | 0.83 |
| 50~63 | 1.28 | 1.25 | 1.18 | 1.13 | 1.08 1.03 | 1 | 0.96 | 0.91 | 0.87 | 0.82 |
1P-N A6oN Miniature circuit breaker
Compliant standards IEC/EN60898-1
Compliant certification CE
Major function
Overload protection,shortcircuit protection,positive isolation
Technical parameters
0 Rated current:6A,1A,16A,2A,25A,32A,4A;
0 Rated voltage:230V;
0 Frequency: 50/60Hz;
0 Thermal magnetic release: C,D;
0 Number of poles:1P+N;
0 Mechanicalife:200o0 cycles;
0 Electrical life:10000 cycles;
0 Rated short-circuit breaking capacity(lcu):6000A;
0 Short-circuit breaking capacity(lcs): 6000A;
0 Rated impulse withstand voltage(Uimp): 4kV;
0 Power consumption on each pole of the circuit breaker: see Table 1.
| Rated current In (A) | Maximum powerconsumption per pole (W) |
| 6~10 | 2 |
| 16~32 | 3.5 |
| 40 | 5 |
QJF1L-63 Residual Current Operated Circuit Breaker without over-current protection (Magnetic)
1.GENERAL
Function
Control electric circuits.
Protect people against indirect contactsand additional
protection against direct contacts.
Protect installationsagainstfire hazard due to insulation faults.Residual currentcircuitbreakersare used in housing,tertiarysectorand industry.
2.TECHNICALDATA
| Standard | IEC/EN61008-1 | IEC/EN61423-1 | |||||
| Electrical features | Type (waveform of the earth leakage sensed) | AC,A | AC-G,A-G,A-SI | AC,A | AC-S,A-S | F | |
| Rated current In | A | 16,25,32,40,63 | 16,25,32,40,63 | 80,100 | 63,80,100 | 25,40,63 | |
| Poles | 2P,4P | ||||||
| Rated voltage Ue | V | 230/400~240/415,110/127 (2P) | 230/400~240/415 | ||||
| Rated senstivityl△n | A | 0.01for1P+N25A, 0.03,0.1,0.3,0.5 | 0.03,0.1,0.3 | 0.03,0.1,0.3 | 0.1,0.3 | 0.03,0.1,0.3 | |
| Insulation voltage Ui | V | 500 | |||||
| Rated residual making and | A | 500 (In=25A/40A) | 500 (In=25A/40A) | 1000 | 1000 | 500 (In=25A/40A) | |
| breakingcapacityl△m | 630 (In=63A) | 630 (In=63A) | (In=80A/100A)|(In=63A/80A/100A) | 630 (In=63A) | |||
| Short-circuit current Inc=l△c | A | 6000/10000 | 10000 | ||||
| SCPD fuse | A | 中 | 10000 | ||||
| break time underl△n | S | 10m-100mas | (Nomaltype) | 150msy0ms | ≤0.1(Normal type) | ||
| Rated frequency | Hz | 50/60 | |||||
| Ratedimpulsewithstandvoltage(1.2/50) Uimp Dielectric test voltage at ind. | V | 6000 | |||||
| Freq.for 1 min | kV | 2 | |||||
| Mechanical | Pollution degree | 2 | |||||
| Electricallife | 2,000 | ||||||
| Mechanicallife | 2,000 | ||||||
| Fault current indicator | Yes | ||||||
| Protectiondegree Ambienttemperature | IP20 | ||||||
| (withdailyaverage | ℃ | -25...-40 | |||||
| Terminal connection type | Storage temperation | ℃ | -25...*470 | ||||
3.OVERALLANDMOUNTINGDIMENSIONS(MM)
SEZDResidual Current Operated Circuit Breaker without over-current protection (Magnetic)
1.GENERAL
Function
Control electric circuits.
Protect people against indirect contacts and additional
protection against direct contacts.
Protect installationsagainst fire hazard due to insulation faults.Residual current circuit breakersare used in housing,tertiarysectorand industry.
2.TECHNICALDATA
| name | argument | |
| Number of poles | 2P | 4P |
| Rated current | (A)6-100 | (A)6-100 |
| Operating voltage | 230V | 400V |
| Rated frequency | Hz50/60 | Hz50/60 |
| sensitivity | 30MA100MA | 30MA500MA |
| Tripmode | M:2P | M:4P |
| E:2P | E:4P | |
| Ratedbreaking capacity | 6KA | |
| Utilzationcategory | A | |
| Mechanical life | 20000 | |
| Degree of protection | IP20 | |
| Ambient temperature | -25~60℃ | |
| Installation environment | ||
| Install | No obvious shock and vibration Standard rail | |
3.OVERALLANDMOUNTINGDIMENSIONS(MM)
QL1-63 Residual Current Operated Circuit Breaker without over-current protection (Magnetic)
1.GENERAL
Function
Control electric circuits.
Protect people against indirect contactsand additional
protection against direct contacts.
Protect installationsagainstfire hazard due to insulation faults.Residual current circuit breakersare used in housing, tertiarysector and industry.
2.TECHNICALDATA
| Standard | IEC/EN61008-1 | IEC/EN62428-1 | |||||
| Electrical features | Type (waveform of the earth leakage sensed) | AC,A | AC-G,A-G,A-SI | AC,A | AC-S,A-S | F | |
| Rated current In | A | 16,25,32,40,63 | 16,25,32,40,63 | 80,100 | 63,80,100 | 25,40,63 | |
| Poles | 2P,4P | ||||||
| Rated voltage Ue | 230/400~240/415,110/127 (2P) | 230/400~240/415 | |||||
| Rated sensivity △n | 0.01for1P+N25A, 0.03,0.1,0.3,0.5 | 0.03,0.1,0.3 | 0.03,0.1,0.3 | 0.1,0.3 | 0.03,0.1,0.3 | ||
| Insulation voltage Ui | 500 | ||||||
| Rated residual making and | V | 500 (In=25A/40A) | 500 (In=25A/40A) | 1000 | 1000 | 500 (In=25A/40A) | |
| breaking capacityl△m | A | 630 (In=63A) | 630 (In=63A) | (In=80A/100A)|(In=63A/80A/100A) | 630 (In=63A) | ||
| Short-circuit current Inc=l△c | A | 6000/10000 | 10000 | 10000 | |||
| SCPD fuse | 中 | ||||||
| break time underl△n | ≤0.1(Normal type), | ≤0.3V | 150ms~500ms | ≤0.1(Normal type) | |||
| Rated frequency | Hz | 10ms~300ms(G/Sl type). | (Normaltype) 50/60 | (S type) | |||
| Ratedimpulsewithstandvoltage(1.2/50) Uimp | V | 6000 | |||||
| Dielectrictestvoltageatind. Freq.for1min | kV | 2 | |||||
| Pollutiondegree | 2 | ||||||
| Mechanical | Electrical life | 2,000 | |||||
| Mechanicallife | 2,000 | ||||||
| Fault current indicator | Yes | ||||||
| Protection degree | IP20 | ||||||
| Ambient temperature | ℃ | -25...+40 | |||||
| (withdailyaverage | ℃ | -25...-.70 | |||||
| Terminal connection type | |||||||
3.OVERALLANDMOUNTINGDIMENSIONS(MM)
SHDResidual Current Operated Circuit Breaker without over-current protection (Magnetic)
1.PRODUCTINTRODUCTION
Instructions
One,three-phase zero line motor leakage protector Second,canreplace the ic653Pvigiproductseparationinstallation
advantage
1.The fault indication isclear
2.Small size and easy installation
3.Electromagnetic trip electronic interference
2.TECHNICALDATA
| name | argument | |
| Number of poles | 2P | 4P |
| Rated current | (A) 6-100 | (A)6-100 |
| Operating voltage | 230V | 400V |
| Rated frequency | Hz50/60 | Hz50/60 |
| sensitivity | 30MA100MA | 30MA500MA |
| Tripmode | M:2P | M:4P |
| E:2P | E:4P | |
| Ratedbreakingcapacity | 6KA | |
| Utilztion category | A | |
| Mechanical life | 20000 | |
| Degree of protection | IP20 | |
| Ambient temperature | -25~60℃ | |
| Installation environment | No obvious shock and vibration | |
| Install | Standard rail | |
3.OVERALLANDMOUNTINGDIMENSIONS(MM)
F360Residual CurrentOperatedCircuitBreaker without over-current protection (Magnetic)
1.GENERAL
Function
Control electric circuits.
Protect people against indirect contacts and additional
protection against direct contacts.
Protect installationsagainstfire hazard due to insulation faults.Residual currentcircuit breakersareused in housing,tertiarysectorand industry.
2.TECHNICALDATA
| Standard | IEC/EN61008-1 | IEC/EN62423-1 | |||||
| Electrical features | Trth wavaormonfthe | AC,A | AC-G,A-G,A-SI | AC,A | AC-S,A-S | F | |
| Rated current In | A | 16,25,32,40,63 | 16,25,32,40, 63 | 80,100 | 63,80,100 | 25,40,63 | |
| Poles | 2P,4P | ||||||
| Rated voltage Ue | V | 230/400~240/415,110/127 (2P) | 230/400~240/415 | ||||
| Rated sensitivityl△n | A | 0.01for1P+N25A, 0.03,0.1,0.3,0.5 | 0.03,0.1,0.3 | 0.03,0.1,0.3 | 0.1,0.3 | 0.03,0.1, 0.3 | |
| Insulationvoltage Ui | V | 500 | |||||
| Ratedrngsdual malingad | A | 500(In-254/40A | 500(In-254/40A) | (In-10A/1004) | (n-63100A100A) | 500(In-254/40A) | |
| Short-circuit current Inc=l△c | A A | 6000/10000 | 10000 | ||||
| SCPD fuse | 中 ≤0.1(Normal type), | 10000 | |||||
| break time underl△n | s | 10ms~300ms(G/Sl type). | ≤0.3V (Normal type) | 150ms~500ms (S type) | ≤0.1(Normal type) | ||
| Rated frequency | Hz | 50/60 | |||||
| Ratedimpulsewithstandvoltage(1.2/50) Uimp | V | 6000 | |||||
| kV | 2 | ||||||
| Pollutiondegree | 2 2,000 | ||||||
| Mechanical features | Electrical life | ||||||
| Mechanical life | 2,000 | ||||||
| Fault current indicator | Yes | ||||||
| Protection degree | IP20 | ||||||
| Ambient temperature (withdailyaverage | ℃ | -25...-40 | |||||
| Storage temperation | ℃ | -25...-.70 | |||||
| Terminal connection type | |||||||
3.PRODUCTPORTFOLIOCHART
F2F4 Residual Current Operated Circuit Breaker without over-current protection (Magnetic)
1.GENERAL
Function
Control electriccircuits.
Protect people against indirect contactsand additional protectionagainstdirectcontacts.
Protectinstallationsagainstfirehazarddueto insulation faults.Residualcurrentcircuit breakersare used in housing,tertiary sector and industry.
2.TECHNICALDATA
| Standard | IEC/EN61008-1 | IEC/EN62423& IEC/EN61008-1 | |||||
| Electrical features | Type (waveform of the earth leakage sensed) | AC,A | AC-G,A-G,A-SI | AC,A | AC-S,A-S | F | |
| Rated current In | 16,25,32,40,63 | 16,25,32,40,63 | 80,100 | 63,80,100 | 25,40,63 | ||
| Poles | 2P,4P | ||||||
| Rated voltage Ue | 230/400~240/415,110/127 (2P) | 230/400~240/415 | |||||
| Rated sensitivityl△n | 0.01for1P+N25A, 0.03,0.1,0.3,0.5 | 0.03, 0.1, 0.3 | 0.03, 0.1, 0.3 | 0.1,0.3 | 0.03,0.1,0.3 | ||
| Insulationvoltage Ui | 500 | ||||||
| Rredingcal mtyfand | 500In-254/40A) | 500 0-254A | (n-0/100A)00A) | 5000In-2540A | |||
| A A | |||||||
| Short-circuit current Inc=l△c | A | 6000/10000 | 10000 | ||||
| SCPD fuse | |||||||
| break time under1△n | (Nomatyre) | 150msy50ms | ≤0.1(Normal type) | ||||
| Rated frequency | 50/60 | ||||||
| Ratedimpulse withstandvoltage(1.2/50) Uimp | kV | 6000 | |||||
| Pollution degree | 2 | ||||||
| 2 | |||||||
| Mechanical | Electrical life | 2,000 | |||||
| Mechanical life | 2,000 | ||||||
| Fault current indicator | Yes | ||||||
| Protectiondegree | IP20 | ||||||
| -25../+40 | |||||||
| ℃ | -25...-70 | ||||||
| Storagetemperation Terminal connection type | |||||||
3.OVERALLANDMOUNTINGDIMENSIONS(MM)
DXID Residual Current Operated Circuit Breaker without over-current protection (Magnetic)
1.GENERAL
Function
Control electric circuits.
Protect people against indirect contacts and additional
protectionagainstdirectcontacts.
Protect installationsagainstfire hazarddue toinsulation faults.Residual current circuit breakersare used in housing,tertiarysector and industry.
2.TECHNICALDATA
| Standard | IEC/EN61008-1 | IEC/EN 62423-1 | |||||
| Electrical features | Type (waveform of the earth leakage sensed) | AC,A | AC-G,A-G,A-SI | AC,A | AC-S,A-S | F | |
| Rated current In | A | 16,25,32,40,63 | 16,25,32,40,63 | 80,100 | 63,80,100 | 25,40,63 | |
| Poles | 2P,4P | ||||||
| Rated voltage Ue | V | 230/400~240/415,110/127 (2P) | 230/400~240/415 | ||||
| Rated sensitivity △n | A | 0.01for1P+N25A, 0.03,0.1,0.3,0.5 | 0.03,0.1,0.3 | 0.03, 0.1,0.3 | 0.1,0.3 | 0.03,0.1,0.3 | |
| Insulationvoltage Ui | V | 500 | |||||
| Rbreakingca mty1and | A | 500 (In-25404) | 500(In-2540A | (0 | 500n-254A | ||
| Short-circuit current Inc=l△c | A | 6000/10000 | 10000 | ||||
| SCPD fuse | A | 中 | 10000 | ||||
| break time under1△n | s | 10m-1ma/styr | (Nomaltyp) | ||||
| Rated frequency | Hz | 50/60 | 150msy50ms | ≤0.1(Normal type) | |||
| Rated impulse withstand voltage(1.2/5o) Uimp | V | 6000 | |||||
| kV | 2 | ||||||
| Pollutiondegree | 2 | ||||||
| Mechanical features | Electrical life | 2,000 | |||||
| Mechanical life | 2,000 | ||||||
| Fault currentindicator | Yes | ||||||
| Protectiondegree | IP20 | ||||||
| (wtmbinteragersure) | ℃ | -25...-40 | |||||
| Storage temperation | ℃ | -25...-.70 | |||||
| Terminal connection type | |||||||
3.OVERALLANDMOUNTINGDIMENSIONS(MM)
ID Residual Current Operated Circuit Breaker without over-current protection (Magnetic)
1.GENERAL
Function
Control electriccircuits.
Protect people against indirect contacts and additional
protectionagainstdirectcontacts.
Protectistallsfds
2.TECHNICALDATA
| Numberof poles | 2P | 4P |
| Rated current | (A)6-63 | (A)6-63 |
| Operating voltage | 230V | 400V |
| Rated frequency | Hz50/60 | Hz50/60 |
| sensitivity | 30MA100MA | 30MA500MA |
| Tripmode | M:2P | M:4P |
| E:2P | E:4P | |
| Rated breakingcapacity | 6KA | |
| Utilizationcategory | A | |
| Mechanical life | 2000 | |
| Degree of protection | IP20 | |
| Ambienttemperature | -25~65℃ | |
| Installation environment | No obviousshock and vibration | |
| Install | Standardrail | |
3.OVERALLANDMOUNTINGDIMENSIONS(MM)
QYM1/1P-125DC
QYM1 DC/AC Series Moulded Case Circuit Breaker
General
Themoulded case circuit breakerwillprovide protection for thecircuit and equipment incaseof overload, short circuit and under voltage condition occurred in the powerdistribution circuit. Besides,itcanalsoprovideprotectionofoverload,shortcircuitandundervoltageforthenonfrequentstart of motor.
Frame size
QYM1seriesmoulded casecircuitbreaker:
63A,125A,160A,250A,400A,630A,800A1000A,1250A,1600A
QYM1 series moulded case circuit breaker
Ratedoperationalvoltage:Ue:220V/230V/240V,380V/400V/415V,500V,690V Breaking capacity code:E,S,F,H
Number of poles:1P,2P,3P,4P
Frequency:AC,DC
Release type:thermal magnetic fixed type;magnetic fixed type;electronic type. Installation method: Fixed type; plug-in type
QYM2 Series Moulded-case Circuit Breaker
QYM2/3P-125A
Compliant standards IEC 60947-2
Major function
Themoulded case circuit breaker willprovide protection for thecircuit and equipmentincaseof overload, short circuit and under voltage conditionoccurred in thepower distributioncircuit.Besides,itcanalso provide protection of overload,short circuit and under voltage for the nonfrequent startof motor
Technical parameters
Ratedcurrent:32A4A5A63A8A100A125A,160A,200A,25A32A,400A,630A,800A,00A5 A,1600A,2000A;
Ratedvoltage:220V/230V/240V380V/400V/415V,500V,690V
Frequency: 50/60Hz;
Thermal magnetic release:B,C,D;
Number of poles:3P、4P
Mechanicalife:20ooo cycles;
Electrical life:10000 cycles;
Ratedshort-circuitbreaking capacity(lcu):25KA,35KA,50KA,75KA(220V/230V/240V)
Short-circuitbreakingcapacity (lcs):18KA,25KA,35KA,50KA(220V/230V/40V)
Rated insulation voltage Ui:800V
Rated impulse withstand voltage (Uimp):8kV;
Nameplateinterpretation
Product type:Frame size;breaking capacity,poles number
Ui: Rated insulation voltage
Frequency of A.C.
Uimp: Rated impulsive withstand voltage
Ue:Rated operational voltage The product is in conformity with standard IEC/EN 60947.2 Icu/lcs: Ultimate short circuit breaking capacity/Service short circuit breaking capacity + 4 0 { c } :Ambient temperature Electrical symbolforcircuitbreakerwith isolating function CatA:Utilizationcategory of breaker
In:Rated operational current
li:10lnMultipleofcurrent of transientbehavior
The product is inconformitywith standard IEC/EN60947-2
QYM2/3P-160A
| Serial number | Productname | Serial number | Productname |
| 1 | Body | 5 | Handheld test module(optional) |
| 2 | Shunt release (optional) | 6 | Under voltage release (optional) |
| 3 | Motor-drivenmechanism (optional) | 7 | Interphase barrier (standard) |
| 4 | Auxiliary contact (optional) |
BEZC Series Moulded Case Circuit Breaker
| lechhlcalSpeclficatioh | ||||||||
| Type | curet d | nPolber | Polution | |||||
| BEZC-100B | 15,16,20250 | 3P | 10 755 | |||||
| 45.16,20.25.3, 3P 80,100 | 2.5 25 | |||||||
| BEZC-100F | 10 | |||||||
| BEZC-100N | 15,16,20,25, 30,32,40,45, 50,60,63,75, 80,100 15,16,20, | 1P | 7.5 5 | |||||
| 18 | ||||||||
| 2.5 | ||||||||
| 25,30,32, 406.0 | 3P,4P 1P | 25 15 | ||||||
| 25 | ||||||||
| BEZC-100H | 5 | |||||||
| 3030 | ||||||||
| 24P | ||||||||
| BEZC-250F | 100.15.150 225,250 | 3P | 25 18 | |||||
| 15 5 | ||||||||
| BEZC-250N | ≤690 | |||||||
| 50 | ||||||||
| 100.126.150 225,250 | 3P 690 | 25 | ||||||
| 3 | 20 | |||||||
| 8 | ||||||||
| BEZC-250H | 180.17800 2P,3P 63,80, | 85 | ||||||
| 325 | ||||||||
| 25 | 10 | |||||||
| BEZC-250N 160,175,200 225,250 63,80, 100,125,150 | 100,125,150 | 4P | 25 | |||||
| 20 8 | ||||||||
| BEZC-250H | 4P 160,175,200 225,250 | 36 25 10 | ||||||
| BEZCV250N | 63,80, 100,175 225,250 | 3P,4P | 10 | 25 20 | ||||
| BEZCV250H | 63,80, 100,125,150 160,175,200 | 3P,4P | 36 | |||||
| 25 | ||||||||
| BEZC400N | 225,250 250,300,320 | - - | ||||||
| 36 | ||||||||
| 350,400 | 3P,4P | 15 | ||||||
| BEZC400H | 50 20 | |||||||
GS Series Moulded Case Circuit Breaker
Application
GSseriesmoulded casecircuitbreaker isapplicable tothecircuit ofAC5O/6oHz,rated insulation voltage 690Vratedoperatingvoltage uptoAC 95OV,rated current10A-160OA forpowerdistribution andprotectionof electrical equipmentincaseofoverload,shortcircuitandundervoltageandalsofor unfrequentswitchover of electrical circuits under normal conditions.The MCCB conforms to standard IEC60947-2.
Technical Specification
GS-125
| Type | Rated current of trip (In A) | Number of poles | Rated current(A) | Rated frequency(Hz) | Arcing-over distance (mm) | |
| Icu/cos Φ | lcs/cos Φ | |||||
| GS-125B | 10,12.5,16,20, 25,32,40,50,63, 80,100,125 | 1P | 25/0.25 | 25/0.25 | 50/60 | 30 |
| 10,12.5,16,20, 25,32,40,50,63, | ||||||
| GS-125B | 25/0.25 | 10/0.3 | ≤30 | |||
| GS-125N GS-125H | 30/0.25 50/0.25 | 15/0.3 35/0.25 | ≤30 ≤30 | |||
| GS-160B | 50,63,80, 100,125,160 | 30/0.25 | 15/0.3 | ≤30 | ||
| GS-160N | 35/0.25 | 25/0.25 | ≤30 | |||
| GS-160H | 50/0.25 | 35/0.25 | ≤30 | |||
| GS-250N | 35/0.25 | 25/0.25 | ≤30 | |||
| 50/0.25 5/0.25 | ||||||
| GS-250S | 125,160, 200,250 | 65/0.2 | 45/0.25 | ≤30 ≤30 | ||
| GS-250H GS-250L | 85/0.2 | 60/0.2 | ≤60 | |||
| GS-400N | 35/0.25 | 25/0.25 | ≤60 | |||
| GS-400S | 250,315,400 400,500,630 | 3P | 50/0.25 | 35/0.25 | ≤60 | |
| GS-400H | 70/0.2 | 20/0.25 | ≤60 | |||
| GS-400L | 100/0.2 | 75/0.2 | ≤80 | |||
| GS-630N | 35/0.25 | 25/0.25 | ≤80 | |||
| GS-630S | 20/0.25 | 35/0.25 | ≤80 | |||
| GS-630H | 70/0.2 | 50/0.25 | ≤80 | |||
| GS-630L | 630,700,800 | 100/0.2 | 70/0.2 | ≤100 | ||
| GS-800N | 50/0.25 | 35/0.25 | ≤80 | |||
| GS-800S | 50/0.25 | 35/0.25 | ≤80 | |||
| GS-800H | 70/0.2 | 50/0.25 | ≤80 | |||
| GS-800L | 630,800, 1000,1250 | 100/0.2 | 70/0.25 | ≤100 | ||
| GS-1250N | 50/0.25 | 35/0.25 | ≤100 | |||
| GS-1250S | 50/0.25 | 35/0.25 | ≤100 | |||
| GS-1250H | 70/0.2 100/0.2 | 50/0.25 | ≤100 | |||
| GS-1250L | 80,1000, 1250,1600 | 50/0.25 | 70/0.25 | ≤120 | ||
| GS-1600N | 50/0.25 | 35/0.25 | ≤100 | |||
| GS-1600S | 70/0.2 | 35/0.25 | ≤100 ≤100 | |||
| GS-1600H | 50/0.25 | |||||
| GS-1600L | 100/0.2 | 70/0.2 | ≤120 | |||
GS-250
Working Conditions
GS-630
0 Ambient temperature
0 Top limit:+40℃
0 Buttom limit:-5℃
0 Average value within:24≤+35℃
0 Altitudes:Altitudes≤2000m
0 Atmospheric conditions
0 Humidity shall be less than 5 0 % below + 4 0 \tau
0 Maximum relative humidity is 9 0 % in dampest
0 Monthwiththeaverage temperatureabove + 2 5 \Upsilon
0 Pollution degree:3
NSX Series Moulded Case Circuit Breaker
Application
NSXseriesmouldedcase circuit breaker isapplicable tothecircuit ofAC5O/6oHz,rated insulation voltage690VratedoperatingvoltageuptoAC950V,ratedcurrent12.5A-1600Aforpowerdistribution andprotectionof electrical equipmentincaseofoverload,shortcircuitandundervoltageandalsofor unfrequentswitchoverofelectrical circuitsundernormal conditions.The MCCBconformstostandard IEC60947-2.
Technical Specification
NSX-100N3P
NSX-250N-3P
| Type | Rated cuirentaof | umber | Rated | Rated | Arcing- | Uitimate short | Short circuit capaity breaking | Operation performance | |
| ON OFF | |||||||||
| NSX-100D | 12.5,16, 20,25,32, | 16,20,25, 32,40,50, 63,80,100, 125,160 | 950 | ≤690 | 18 | 18 | 1500 | 8500 | |
| NSX-100N | 25 | 25 | |||||||
| NSX-100H 40,50,63, | 70 | 70 | |||||||
| NSX-100L | 150 | 150 | |||||||
| NSX-160D | 25 | 25 | |||||||
| NSX-160N | 35 | 35 | |||||||
| NSX-160H | 70 | 70 | |||||||
| NSX-160L | 150 | 150 | |||||||
| NSX-250D | 160,180, 3P 200,225, 4P 250 | 36 | 25 25 | 1000 | 7000 | ||||
| NSX-250N | 36 | ||||||||
| NSX-250H | 70 | 70 | |||||||
| NSX-250L | 150 | 150 | |||||||
| NSX-400D | 200,225, 250,300, 315,400 | 25 | 25 | 100 | 4000 | ||||
| NSX-400N | 36 | 36 | |||||||
| NSX-400H | 70 | 70 | |||||||
| NSX-400L | 150 | 150 35 | |||||||
| NSX-630D | 315,350, 400,500, 600,630 | 35 | 45 | 1000 4000 | |||||
| NSX-630N | 45 | ||||||||
| NSX-630H | 70 | ||||||||
| NSX-630L | 150 | ||||||||
NSX-250N-4P
Working Conditions
| Rated current of release(A) | Thermodynamicrelease(ambienttemp+40℃) | Operational current of magnetic release(A) | |
| 1.05ln(coldstate)inoperation time(h) | 1.30ln(heat state) operative time(h) | ||
| In | ≥1 | 10ln ± 20% | |
| 63≤In≤100 | >2 | 10ln±20% | |
| 100≤In≤630 | ≥2 | 5-10ln ±20% | |
| Rated current of release (A) | Thermodynamicrelease(ambienttemp+40℃) | Operational curontof release(A) | |||
| 1.0ln(cold state) operative time(h) | 1.20ln(heat state) operative time(h) | 1.50ln(heat state) operative time(h) | 1.01In (heat state) operative time(h) | ||
| 12.5≤n≤400 | >2 | ≤4min | 2S| 12ln ± 20% | | |
T
GNSX Series Moulded Case Circuit Breaker
Application
GNSXseriesmouldedcasecircuitbreakerisapplicabletothecircuitofAC5O/6oHz,rated insulation voltage 690VratedoperatingvoltageuptoAC95OV,ratedcurrent12.5A-1600A forpowerdistribution andprotectionofelectricalequipmentincaseofoverload,shortcircuitandundervoltageandalsofor unfrequentswitchover of electrical circuitsundernormal conditions.The MCCBconformstostandard IEC60947-2.
Technical Specification
GNSX-250D-3P
GNSX-400D-3P
| Type | Rated current of trip (In A) | Pole number | Rated insulating voltage M | Rated operating distance (mm) | Arcing- over distance (mm) | Uitimate circuit breakering capaity | Short breaking capaity | poforation | |
| ON | OFF | ||||||||
| GNSX-100D | 40,50,63, 80,100 | 16,20,25, 32,40,50, 3P 200,225, 4P | ≤690 | 18 | 18 | 1500 | 8500 | ||
| 12.5,16, 20,25,32, | 25 | ||||||||
| GNSX-100N | 70 | 25 70 | |||||||
| GNSX-100H GNSX-100L | 150 | 150 | |||||||
| GNSX-160D | 25 | 25 | 1000 | 7000 | |||||
| GNSX-160N | 35 | 35 70 | |||||||
| GNSX-160H | 70 | ||||||||
| GNSX-160L | 63,80,100, 125,160 160,180, | 950 | 150 25 | 150 | 1000 | 7000 | |||
| GNSX-250D | 25 | ||||||||
| GNSX-250N | 36 | 36 | |||||||
| GNSX-250H | 70 | 70 | |||||||
| GNSX-250L | 200,225, 250,300, 315,400 | 150 | 150 | 100 4000 | |||||
| GNSX-400D GNSX-400N | 25 36 | 25 36 | |||||||
| GNSX-400H | 70 | 70 | |||||||
| GNSX-400L | 150 | 150 | |||||||
| GNSX-630D | 315,350, 600,630 | 35 | 35 | 1000 | 4000 | ||||
| GNSX-630N | 45 | 45 | |||||||
| 400,500, GNSX-630H | 70 | 70 | |||||||
| GNSX-630L | 150 150 | ||||||||
GNSX-160D-4P
Working Conditions
| Rated current of release(A) | Thermodynamicrelease(ambienttemp+40℃) | Operational currentof magneticrelease(A) | |
| 1.05ln(coldstate)inoperation time(h) | 1.30ln(heatstate) operative time(h) | ||
| In | ≥1 | 10ln ±20% | |
| 63≤In≤100 | >2 | 10ln ±20% | |
| 100≤n≤630 | ≥2 | 5-10ln±20% | |
| Rated current of release (A) | Thermodynamicrelease(ambienttemp+40℃) | Operational current of magnetic release(A) | |||
| 1.0ln(cold state) operative time(h) | 1.20ln(heatstate) operative time(h) | 1.50ln(heat state) operative time(h) | 1.01ln (heat state) operative time(h) | ||
| 12.5≤n≤400 | ≤4min | 2S| 12ln ± 20% | | ||
DZ518(GV2-P)
Motor Protection Circuit Breaker DZ518(GV2/GV3)
Application
TheDZ518circuit breaker(GV3mouldedcase circuitbreaker)issuitable for thealternating voltage to 690V,the electric current1toin the8OA electriccircuit,takes three phase mouse cageasychronous electric motoroverload,breaks,short-crcuitprotectionandnotfrequentstartingcontrolusesmayerve asthedistributionlineprotectionandthenotfrequent,load transformation,butalsomaydoisolates the use.
Main technical parameters
DZ518(GV2-MC..)
| Type | Rated curent | Motoroutpot | Setting range(A) | Order No. | |
| Thermad releases | ovinstantanreouse | ||||
| GV3-M(ME) | 2.5 | 0.75 | 1.6-2.5 | 30 | DZ518-80(GV3-M07) |
| 4 | 1.1/1.5 | 2.5-4 | 48 | DZ518-80(GV3-M08) | |
| 6 | 2.2 | 4-6 | 72 | DZ518-80(GV3-M10) | |
| 10 | 3/4 | 6-10 | 120 | DZ518-80(GV3-M14) | |
| 16 | 5.5/7.5 | 10-16 | 190 | DZ518-80(GV3-M20) | |
| 20 | 7.5/10 | 16-20 | 240 | DZ518-80(GV3-M21) | |
| 25 | 11 | 20-25 | 300 | DZ518-80(GV3-M25) | |
| 40 | 18.5 | 25-40 | 480 | DZ518-80(GV3-M40) | |
| 63 | 28 | 40-63 | 720 | DZ518-80(GV3-M63) | |
| 80 | 32 | 56-80 | 960 | DZ518-80(GV3-M80) | |
DZ518(GV2-MC..)
DZ518M(GV2/GV3) Accessories
| Namesofaccessories | Code | The type of comtacts | Installation place |
| Instantaneousauxiliarycontacts | A01 | 1NO+1NC | The right of breaker (1 PCS can be installed) |
| A02 | 2NO |
DZ518(GV3-M)
DZ518(GV3-ME)
| DZ518(GV2-M)(ME)(P) | DZ518(GV2-RS) | DZ518(GV2-LS)(LE) | |||
| M01C | 0.1-0.16 | RS01C | 0.1-0.16 | ||
| M02C | 0.16-0.25 | RS02C | 0.16-0.25 | ||
| M03C | 0.25-0.4 | RS03C | 0.25-0.4 | LS03 | |
| M04C | 0.4-0.63 | RS04C | 0.4-0.63 | LS04 | |
| M05C | 0.63-1 | RS05C | 0.63-1 | LS05 | |
| M06C | 1-1.6 | RS06C | 1-1.6 | LS06 | |
| M07C | 1.6-2.5 | RS07C | 1.6-2.5 | LS07 | |
| M08C | 2.5-4 | RS08C | 2.5-4 | LS08 | |
| M10C | 4-6.3 | RS10C | 4-6.3 | LS10 | |
| M14C | 6-10 | RS14C | 6-10 | LS14 | |
| M16C | 9-14 | RS16C | 9-14 | LS16 | |
| M18C | 10-16 | RS18C | 10-16 | LS18 | |
| M20C | 13-18 | RS20C | 13-18 | LS20 | |
| M21C | 17-23 | RS21C | 17-23 | LS21 | |
| M22C | 20-25 | RS22C | 20-25 | LS22 | |
| M32C | 24-32 | RS32C | 24-32 | ||
1P+N DPN Circuit Breaker
Technical parameters
| Pole | 1P+N |
| Amp | 6A10A16A20A25A32A40A |
| Din rail | 18mmwidth |
Timer Switch
Latching Relay
9VDC,9VDC+220VBatterySmokeDetectorAlarm
CHARACTERISTIC TECHNOLOGY
Operatingvoltage:9VDC,9VDC+220V Detection range:360 CE IP20 Alarm frequency:10m Operating temperature: - 1 0 ~ + 4 0 ^ { \circ } 1 Medidas:13.3x4cm Sound level: 85dB a 3m Ambient temperature:s95%
INSTALACION
9VDC,9V DC+220V battery smoke detector alarm On the basis of mounting on the ceiling or walloverlapping.
With a loud alarm.
Easyto installby swivelingand clicking on the base.
CJX2-D(XLC1-D) Series AC Contactor
Application
CJX2-DseriesAC contactor is suitabe forusing in the circuitsupto therated voltage66oVAC50/60Hz, ratedcurrentupto66oVformaking,breaking,frequentlystarting&controlingtheACmotor,comied with theauxiliarycontact block,timerdelay&machine-interlocking deviceetc,it becomes the delay contactormechanical interlockingcontactorstar-edltastarterwiththethermalrelayitiscombined into theelectromagneticstarier.
Technical Data
| Type | D09 | D12 | D18 | D25 | D32 | D40 | D50 | D65 | ||
| Rated working current(A) | AC3 | 9 | 12 | 18 | 25 | 32 | 40 | 50 | 65 | |
| AC1 | 3.5 | 5 | 7.7 | 8.5 | 12 | 18.5 | 24 | 28 | ||
| AC3capacityof phase3 squirrel-cage motorAC3(kW) | 220/230V | 2.2 | 3 | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | |
| 380/400V | 4 | 5.5 | 7.5 | 11 | 15 | 18.5 | 22 | 30 | ||
| 415V | 4 | 5.5 | 9 | 11 | 15 | 22 | 25 | 37 | ||
| 500V | 5.5 | 7.5 | 10 | 15 | 18.5 | 22 | 30 | 37 | ||
| 660/690V | 5.5 | 7.5 | 10 | 15 | 18.5 | 30 | 33 | 37 | ||
| Rated heat current(A) | 20 | 20 | 32 | 40 | 50 | 60 | 80 | 80 | ||
| Electrical life | AC3×10+ | 100 | 100 | 100 | 100 | 80 | 80 | 60 | 60 | |
| AC4×10+ | 20 | 20 | 20 | 20 | 20 | 15 | 15 | 15 | ||
| Mechanical life×10* | 100 | 1000 | 1000 | 1000 | 800 | 800 | 800 | 800 | ||
| Numberof thecontacts | 3P+NO | 3P+NO+NC | ||||||||
| D80 | D95 | D115 | D150 | D170 | D205 | D245 | D300 | D410 | D475 | D620 |
| 80 | 95 | 115 | 150 | 170 | 205 | 245 | 300 | 410 | 475 | 620 |
| 37 | 44 | 52 | 60 | 75 | 85 | 105 | 117 | 138 | 147 | 180 |
| 22 | 25 | 30 | 40 | 55 | 63 | 75 | 100 | 110 | 147 | 200 |
| 37 | 45 | 55 | 75 | 90 | 110 | 132 | 160 | 220 | 265 | 335 |
| 45 | 45 | 59 | 80 | 100 | 110 | 132 | 180 | 220 | 2280 | 375 |
| 55 | 55 | 75 | 90 | 110 | 129 | 160 | 200 | 250 | 355 | 400 |
| 45 | 55 | 80 | 100 | 110 | 129 | 160 | 220 | 280 | 355 | 450 |
| 125 | 125 | 200 | 250 | 250 | 275 | 315 | 400 | 500 | 700 | 1000 |
| 60 | 60 | 200 | 60 | 60 | 50 | 50 | 50 | 30 | 30 | 20 |
| 10 | 10 | 15 | 15 | 15 | 15 | 15 | 15 | 8 | 8 | 5 |
| 600 | 600 | 300 | 300 | 300 | 300 | 300 | 300 | 100 | 100 | 100 |
| 3P+NC+NO | ||||||||||
Standard Control Circuit Voltages
| Volts | 24 | 42 | 48 | 110 | 220 | 230 | 240 |
| 50Hz | B5 | D5 | E5 | F5 | M5 | P5 | U5 |
| 60Hz | B6 | D6 | E6 | F6 | M6 | P6 | U6 |
| 50/60Hz | B7 | D7 | E7 | F7 | M7 | P7 | U7 |
| Volts | 380 | 400 | 415 | 440 | 500 | 660 |
| 50Hz | Q5 | V5 | N5 | R5 | S5 | Y5 |
| 60Hz | Q6 | V6 | N6 | R6 | S6 | Y6 |
| 50/60Hz | Q7 | V7 | N7 | R7 | S7 | Y7 |
New typeCJX2-09、12、18(LC1-D09、12、18)
NewtypeCJX2-25、32、38(LC1-D25、32、38)
Dimension & Mounting Size
New typeCJX2-40、50、65(LC1-D40、50、65)
CJX2-D(XLC1-D) Series AC Contactor
NewtypeCJX2-80、95 (LC1-D80、95)
ForCJX2-D09\~95contactors
| Type | A | B | C | D | E | a | b | Φ |
| CJX2-D09/12 | 47 | 76 | 82 | 11 | 133 | 34/35 | 50/60 | 4.5 |
| CJX2-D18 | 47 | 76 | 87 | 118 | 138 | 34/35 | 50/60 | 4.5 |
| CJX2-D25 | 57 | 86 | 95 | 126 | 146 | 40 | 48 | 4.5 |
| CJX2-D32 | 57 | 86 | 100 | 131 | 151 | 40 | 48 | 4.5 |
| CJX2-D40/65 | 77 | 129 | 116 | 145 | 165 | 40 | 100/110 | 6.5 |
| CJX2-D80/95 | 87 | 129 | 127 | 175 | 195 | 40 | 100/110 | 6.5 |
| Type | A | B | C | b1 | P | Q | s | Q1 | M | N | L | Ga | Ha | |
| CJX2-D115 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | ||
| CJX2-D150 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | m6 | ||
| CJX2-D170 | 158 | 120 | 132 | 158 | 35 | 60 | 17 | 25 | 134 | 96.2 | 75 | M6 | 120-106 | |
| CJX2-D205 | 168.5 | 174 | 181 | 137 | 40 | 69 | 20 | 59.4 | 154 | 127 | 113.5 | M8 | 80 | 120-106 |
| CJX2-D245 | 168.5 | 19 | 181 | 137 | 48 | 69 | 25 | 51.5 | 172 | 127 | 113.5M10 | 80 | 120-106 | |
| CJX2-D300 | 213 | 206 | 219 | 145 | 48 | 91 | 25 | 74 | 181 | 158 | 145 | M10 | 80 | 120-106 |
| CJX2-D410 | 213 | 206 | 219 | 209 | 48 | 91 | 25 | 74 | 181 | 158 | 146 | M10 | 80 | 120-106 |
| CJX2-D475 | 233 | 238 | 232 | 209 | 55 | 108 | 30 | 77 | 208 | 172 | 145 | M10 | 80 | 180 |
| CJX2-D620 | 309 | 304 | 255 | 280 | 80 | 140 | 40 | 89 | 264 | 202 | 155 | M12 | 80 | 180 |