TICA MODULARAIRHANDLINGUNIT TAC/TBC Series
A irPioneer
Establishedin1991,TICAisanationalhigh-techenterprisethatisdedicatedtobecoming theworld'sleading supplierand service provider of smart and clean environment and green energy systems.TICA isalsoa marketleader in Chinaintermsofcleanair processing inextremeenvironments,apractitionerof energy conservationinbuildingand industrialenvironments,andapioneerinlow-temperaturepowergenerationand greenandrenewableenergies.TiCAownsfive productionsitesinNanjing,Tianjin,Guangzhou,Chengdu andKualaLumpur,eight plants,andanetworkofover70salesandserviceoutletsaroundtheworld.
In the industrial and biological clean room segment, TlCA's market share has achievedover40%inChina.
Servingover7,oooGrade-AClass3andClass2hospitals InfectiousHospital (Uzbekistan),Al Hospital(Fiji),BrawijayaHospital(Indonesia),etc.
Servingover5,oooGMP-certifiedpharmaceuticalplants Bayer (Germany),DexaPalembang(Indonesia),MerrymedFarmFactory(Uzbekistan),etc.
Servingover2,0o0microelectronicmanufacturers WesternDigital (Malaysia),LongshengTechnology (Cambodia),ApexCircuit (Thailand),etc.
Content
AirPioneer
Inventionof frameless fullmoduleairconditioning cabinetstructure China'sfirst ISOClass1ultracleanintegratedenvironmentalsystem China'sfirstnationalbrandwithEUROVENT&AHRlcertifications
Great Originality, Fabulous Craftsmanship Over 30 Years' Professional Experience in Clean Air-Conditioning
1991 Registered TICA
1999 Purifying DX system
2014 ISO Class 1 ultra clean
Design
Application Production Service
Modular design with free
combination
Energy-efficient module with
low resistance
Focusing on low-carbon energy saving solutions Customization base on personalized demand
International first-class manufacturing production line Intelligent orderdesignsystem
Professional sales service Ticare
2017
Obtained MIIT Champion
Product Award
2021
Obtained eco-friendly zero-ODP insulation system&TUVcertification
3TICA—
Introduction
Overview
Aftermore than30yearsoftechnologicaltransformationforAirPioneer,wehaveaccumulatedalotofprojectexperienceand valuablesuggestionsfromcustomersandengineers.Theinnovativemicromoduledesign,leadstoabrand-newcabinetdesign concept,significantly improving the structural flexibility.
Therefore,AirPoneerhashigherenergy-savingpropertyandreliablitymeeting thecustomizationnedsofmoreprofessional scenarios.
Higher-level Casing Critical industrial Ultra-strong installation performance application adaptability
Professional Design
TICA Air Pioneer modular air handling unit has a patented casing structure and excellent detailed design,as wellas outstanding performance in the industry in terms of mechanical strength,air tightness,thermal insulation performance,and anti-cold bridge.(ZL 2014 2 0122442.9) It also meets the EN1886 standard for casing performance and is certified by EUROVENT.
Casing inside is flatlyandseamlesslyspliced No corners with possible dust deposition
Obtained AHRl certification for heat exchangerand RoHS certification for copper pipe
High-efficiency heat exchange,high reliability
5 0 {kg / m ^ { 3 } } high-density polyurethane Lowerheat loss,highstrengthwithout deformation
AirPioneer
Self-developed casing structure
Micromoduledesign
Alabyrinth sealing structure,with the concave andconvexmodules interlocked Aluminum-plasticcompositeprofilewithsoft and hard co-extrusion sealing strip
Eull distributionofcoilsintheunit section Reduced internal resistance,goodenergy savingproperty
YR
Highly-sealedfilter installationframe High-eficiency and energy saving fan
Highest levelof EN1886airtightness Supply cleanairafter filtering
EC fan with higher energy efficiency Cleaner without voluteand belt dust
Full-size door with large space,more convenient repair Seamless foamingofdoor leaf,with goodairtightness Pressure relief design for door handle,ensuring operation safety
Model Selection
Selectunitli-ieof-i.
Unit dimension and filter size
| Model | Internal dimensions (H × W) | External dimensions (H×W) (mm) | Numberoffilters | |||
| mm | TAC | TBC | 24"*24" | 20"*24" | 12"*24" | |
| 012012 | 612*612 | 662*662 | 712*712 | 0 | 0 | 2 |
| 014017 | 714*867 | 764*917 | 814*967 | 0 | 1 | 1 |
| 016023 | 816*1173 | 866*1223 | 916*1273 | 0 | 1 | 2 |
| 020026 | 1020*1326 | 1070*1376 | 1120*1426 | 2 | 0 | 2 |
| 022028 | 1122*1428 | 1172*1478 | 1222*1528 | 2 | 2 | 0 |
| 026031 | 1326*1581 | 1376*1631 | 1426*1681 | 4 | 0 | 2 |
| 028038 | 1428*1938 | 1478*1988 | 1528*2038 | 6 | 0 | 0 |
| 035048 | 1785*2448 | 1835*2498 | 1885*2548 | 8 | 4 | 0 |
| 047063 | 2397*3213 | 2447*3263 | 2497*3313 | 15 | 5 | 0 |
| 050079 | 2550*4029 | 2600*4079 | 2650*4129 | 24 | 0 | 4 |
| 067086 | 3417*4386 | 3467*4436 | 3517*4486 | 35 | 0 | 7 |
| 074102 | 3774*5202 | 3824*5252 | 3874*5302 | 48 | 0 | 6 |
| 096120 | 4896*6120 | 4946*6170 | 4996*6220 | 80 | 0 | 0 |
| 099138 | 5049*7038 | 5099*7088 | 5149*7138 | 88 | 0 | 8 |
| Function section | Simple diagram | Dimensions (mm) (referencevalue) | |
| Water Mist humidifier | |||
| 京京京 | L=900,water eliminator required *With standard drain pan: width | ||
| Width > 69 modulus -- Pipe diameter: DN50 (2 pcs) | |||
| Spray section | |||
| *Customizable according to the specific requirement | L=2uble-rowspray nozzel | ||
| Heat recovery section Dehumidification section | |||
| *Customizable according to the specific requirement | |||
| Fan section | L=700~3500 gto | ||
| Diffuser section | 010013-026035:L=500 028034-047058:L=600 047063-050074:L=800 | ||
| Silencing section | |||
| 050079-099138:L=1000 | |||
| L=500/800/1100 | |||
| Middle section | 010013-026035:L=500 | 028034-099138:L=600 *Placed before the filter section,cooling coil section,heating section,silencing section and other function sections | |
| Air outlet section | |||
| 010013-020028:L=500 026031-035044:L=700 047055-050069:L=1000 067086-074090:L=1400 |
Note
Basic Configuration
| System type | Basicfeatures | Sectionconfiguration | |||||||||||
| Commercial unit | Temperature control ·Applicable to commercial applications | QQQ | |||||||||||
| (/heating section) + fan section | Mixing section + plate filter section + cooling coil section | Mixing section + plate filter section + bag filter section + cooling coil section + | fan section | ||||||||||
| Temperature control ·Apply to 4-pipe commercial applications | |||||||||||||
| Constant temperature and humidity unit | · Temperatureand humidity control ·Applicable to process projects | QQQQQ | 。 | 治 | Mixingsection +platefiltersection+coingcolsection+heatingsection +humidificationsection +fansection +flowequalization | ||||||||
| Constant temperature and humidity with heat recoveryunit | Temperatureand humidity control as well as heat recovery ·Applicable to process projects | ||||||||||||
| Full fresh air unit | ·Focus on fresh air humidity treatment Applicable to air- conditioning systems in comfortable projects | er section + cooling coil section + fansection | |||||||||||
AirPioneer
Industry Solutions
Taking intoaccount thereal needs of applicationscenariosand summinguptheexperienceinthesubdivisionfields,wehave continuouslyimprovedthedesignofAirPioneeraccordingtothe scenariosandarecommittedtoprovidinguserswithextremelyclean andrefinedenergy-savingscenarioapplicationsolutions.
Application features
Hygiene requirements forair supply: 5\~75cfu/m bacterial concentration ISO 5\~8.5 cleanliness
Frequent cleaningand disinfection inside the equipment
Low humidity in special operating department, requiringenergyconsumption for reheating
Product features
·Professionalantibacteralofigurationsuchasboad-spectrumgiencyUVC,silerionantibacterialfiteddust
free fan
·Stainless steel inner plate is suitable for frequent disinfectionand is easy to clean,splicing issmooth
·The DXunitcanprovidelow-humidityairsupplyand precise heatrecovery,therebyguaranteeing theperformanceof the energy-saving system with temperature and humidity control typically used in hospitals.
\* Some functions are optional. Consult TICA factory for detailed configuration.
Application features
Comply with GMP whole-process supervision
Microbial contamination is strictly controlled in the production process
TheairtightnessofHEPA meets the GMPcleanliness requirements
Product features
·With thepatentedsealedHEPAmounting frame (ZL201520338421.5),theairsupplycleanlinessafterHEPAreaches ISOClass5 ·Ozone sterilization isused withavariableairflowfantoachieve disinfection mode switching,meting GMP/FDArequirements : 2 0 + largeair-conditioning testing laboratoriesaccredited by CNAS& ILAC MRA;
· Mature FAT testing solutions
Application features
APCandAMCpollutantsare strictly controlled
Thedemand for freshairis complexand changeable
Largeair flowand highair pressure freshair devicesare equipped
Product features
Primary,mediumandhigheficiencyfilters,aswellasatersprayfiterandchemicalfilterareconfiguredforpurifcationin electronics plants.
·Themulti-stagehigh-effciencyheatexchangersuitableforlargeloadoffreshaircancopewithcomplexandchangeable working conditions and meet indoor constant temperature and humidity requirements.
·High-strength MAU box ensures no deformation under large air flowand large static pressure.
\* Some functions are optional. Consult TICA factory for detailed configuration.
Arrangement of full fresh air MAU function section in electronics plant
Air inlet ^ + primary and medium efficiency ^ + preheating ^ + middlesection ^ + pre-cooling ^ + middle section ^ + waterspray ^ + middlesection ^ + re-cooling ^ + middlesection ^ + reheating ^ + fan ^ + flowequalization ^ + two-stagechemical ^ + middle section ^ + mediumefficiency ^ + high efficiency ^ + airoutlet
Main parameter estimation table for typical applications
| Airflow (m³/h) | esp (Pa) | Motor power (kW) | Pre-coltling | Re-cooling | Preheatng | Reheatitng | Unit dimensions (LxWx H) (mm) |
| 40000 | 800 | 45 | (kW) 550 | (kW) 340 | (kW) 610 | (kW) 105 | 12900×3007×2085 |
| 45000 | 800 | 55 | 610 | 380 | 700 | 115 | 12900×2854×2442 |
| 50000 | 800 | 75 | 685 | 425 | 770 | 130 | 12900×3160×2442 |
| 55000 | 800 | 75 | 750 | 467 | 850 | 145 | 13900×2905×2697 |
| 60000 | 800 | 75 | 810 | 500 | 920 | 155 | 14000×3313×2697 |
| 70000 | 800 | 90 | 950 | 590 | 1080 | 180 | 14000×3619×2850 |
| 80000 | 800 | 90 | 1090 | 680 | 1240 | 205 | 14000×3874×2850 |
| 100000 | 800 | 110 | 1370 | 850 | 1550 | 260 | 15200×3772×3717 |
| 120000 | 800 | 132 | 1630 | 1010 | 1850 | 310 | 15200×4486×3717 |
| 140000 | 800 | 160 | 1900 | 1150 | 2100 | 360 | 15400×4690×4074 |
| 180000 | 800 | 200 | 2450 | 1520 | 2750 | 450 | 15400×5098×4686 |
Notes:1.Theabove isa fullfreshair unit fora chip plant.For other solutions,consult TICAfactory. 2.Themotorpoweristheestimatedvalueofthereseredmargin.Thecurentmotorpowerisbasedontheresistancebroughtbythefinalstage H13 high efficiency filter. 3.Theunitizeisanestimatedvaluendthespaceoftemachineroomshouldbenosmalerthantherequiredsize.Forfrtherdiension selection of the unit,consult TICAfactory. 4.The air inlet conditions in cooling season and heating season are 3 8 ^ { \circ } C / 6 0 % and - 6 ^ { \circ } C / 5 0 % ,respectively. 5.The inlet and outlet temperatures of cold water are \bar { 1 4 } / 2 0 ^ { \circ } { C } (pre-cooling) and 7 1 1 3 ^ { \circ } { C } (re-cooling),respectively,and the inlet and outlet temperatures of hot water are both 3 8 / 3 2 ^ { \circ } \mathsf { C } 6.Therecommended principle forsize selection is that the windward fanspeedofthecoildoes not exceed 2.5m/s.
TICARE
Customized service
Asaprofessionalcleanprocesingsystemintegratorandserviceproviderweprovideairtreatmentdsignandproductcustom izationservicesthatfitheusers'businessformatforvariousextremeindustrialenvironmentsandcomfortablelivingenvironments,fullycoveringcommonneeds.Wearecommittdtoprovidinguserswiththeoptimalcleanenvironmentsolutions
Personalizedcustomizationand quickmodelselection
Specializedoperatingsystem, automaticassociationdesign,quick andaccuratemodelselection,perfect projectmanagement,andquick feedbackoncustomerneeds.
Modelselection functions
Avarietyofstandardizedmodules, directlyprovidingmodelsforselection; Avarietyoffunctionsection configurations,meetingrequirements for process design; Alarge-capacitymodel database, coping withvariousscenariorequirements.
Professional model selection software
Theheatexchangermodelselection softwarepassesAHRlcertification. Thewholemodel selectionsoftware passes.
Euroventcertification.
Output of professional model selection reports
Themodel selection resultscan be outputthroughacomplete setofreports,includingthetechnical parameterdetail listofeach functionsection of theunit, the coil model selection detail list, enthalpy/humiditychart,operatingconditions,fancurve,weight reportandunitdimensiondiagram.
Ai TirPioneer
Core Components
AirPioneer'skeycomponents,areallselectedfromwell-known brands.bringingusersareliableandconvenientexperience.
Component
Core Components
Fan section
Intelligent selection of optimal model,speed,and motor
·The fan impeller and belt pulley are corrected by static and dynamic balance before delivery,and operate stably.
·Adamping device is equipped to greatly reduce the operating noise.
·The impellerand frameare made of high-strength alloy steel plate,with high structural strength.
•Avariety of inverter fansare available.
Centrifugal fan
·Doubleinlet forward/backward · Belt-driven,with good aerodynamic performance ·Variable speed motor is optional
Plug fan
·Direct-drive,easy to clean, small vibration,and low noise ·Variable speed motor is optional
Coil section
·All coilswill undergoa pressure test beforedelivery to ensure worry-free operation.
·Zigzag-shapedcircuitcaneffectivelypreventtheproblemoffreezingcracks duetouncompleteddrainageinwinter.
• All fins are made of hydrophilic aluminum foil to improve heat exchange efficiencyandanti-oxidationeffect.
·ThedrainpanisV-shapedwithaninclinationangleofover 5 ^ { \circ } toensurerapid drainage.
·Witha varietyof circuit formsand AHRl-certified professional selection software,the water resistance can be flexibly optimized.
Cold/hotwatercoil
· High-quality copper pipes and hydrophilic aluminum fins ·Adoption of integrated mechanical expansion pipe
·Excellent cavitation resistance and waterhammerresistance Optionalaluminumfins/steel fins
Filtersection
·Micro modular design of imperial units,with full distribution of filters in the unit height direction
·Uniform air flow,reducing the average air speed of the sectionand improving the filtration efficiency
·Airtight installation and overhaul frame,ensuring low leakagerate and convenient overhaul
自
Platefilter Filtration efficiency: MERV7-MERV9
HEPAfilter Filtration efficiency: E10-E12/H13-H14
Anti-bacterial filtersection
Therequirementofhealthyventilationinpublicplacescanbe metbytheoptionalantibacterialfiltersection:
·Itisrecommendedtochooseamediafilterwithsilverionsto prevent secondarypollution frombacterial reproduction. ·Ahigh-voltageelectrostaticsterilizationfilterisequippedto capture particulatematterand kill microorganisms. ·Photocatalystdegrades toxicand harmful gases in theair, effectivelykillingavarietyofbacteria.
·Meltblown PP plus chemical ion coating
·Microorganisms are killed through high pressure ionization and adsorption.
Core Components
Heat recovery
·Modernair conditioning increasinglyuses heat recoverysystems. ·It not only directly saves operating costs,but also indirectly plays a role in ecological protection.
Humidification section
Humidificationisanessential function inorderto provide healthy air with the right humidity.
The following performance should be considered when choosing a humidifier:
· Saturated efficiency · Humidificationcleanliness · Control precision ·Absorption distance
Air Pioneer
Reference Projects
Reference Projects
Hotel&Commercial Building
The Park Semarang
Holiday Inn Bandung
University
Mangosuthu Unviersity of Technology
Industrial Cooling
Proton Automobile
Semi-Conductor Factory
T&W Electronics
Longsheng Technology
25TICA—