LESSO
PVC Conduit,Trunking and Fittings
PVC Conduit, Trunking and Fittings PVC Multifunctional Trunking and Fitings PVC Triangular Trunking
PVC Round Type Wiring Duct Series PVCAir-conditionDuct
LESSO
ABOUTLESSOGROUP
Established in 1986, LESSO (Stock Code: 02128.HK) is a global leader in home furnishings and building materials. The Group's business portfolio spans plastic piping, building materials and home furnishings, environmental protection, new energy, supply-chain service platforms and others. It offers a wide range of products such as pipes, photovoltaics, plumbing and sanitary ware, integral kitchen materials, integral doors and windows, aluminum formwork and smart scaffolds, water purifiers, water-proofing materials and sealants, fire-fighting equipment, valves, cables,lighting, hygiene materials, items for environmental protection, agricultural facilities, and oceanic aquaculture cages. In 2023, LESSo'ssalesrevenuereachedoverUSD4.38billion.
Since implementing a strategy of globalization and expanding its global presence, LEssO has evolved into a sophisticated multinational. It boasts more than 30 advanced production bases worldwide,broadening its industrial and sales networks to cover Asia,North America,South America, Europe, Africa, and Oceania. This enables LEssO to provide quality products and services for global customers in accordance with its continuously improved strategic layout in a timely and efficient way.
LESSO has founded its R&D center with more than 1,oo0 scientific researchers, nationally accredited enterprise technology center, and two post-doctoral workstations to support its innovation and technical development. The Group has taken a leading role in the revision of over 120 international and Chinese industry standards. LESSO owns over 30o0 patents (some of them are pending), and provides over 10,0o0 varieties of products, making it one of the most comprehensive manufacturers in the piping industry. Its products are utlized globally in different areas, including home decoration, civil construction, municipal water supply, drainage, energy management, power supply and telecommunications, gas supply,fire-fighting,environmental protection,agriculture,oceanic aquaculture,etc.
True to its idea of “Envisioning the Better, Building the Future", LESSO remains committed to creating a better living environment, and advocating ideal cities featuring greenness, livability, and efficiency. With concerted efforts from various sectors, LESsO wil fully play its role in sustaining healthy and beautiful space so that global residents could enjoy a comfortable life.
Contents
PVC Conduit, Trunking and Fittings PVC Round Type Wiring Duct Series
PVC Conduit and Fitting 01-10
Installation 11
PVC Round Type Wiring Duct 12-14
PVC Trunking and Fittings 15-19
Tools .... 20
PVC Multifunctional Trunking and Fittings ... 21-25
PVC Air-conditionDuct... 26-27
Flame-retardant Inulated PVC Triangula... 28-29
Certifications.... 30-34
Test Reports 35-36
Standard:IEC 614,IEC 61386-1,IEC 61386-21,AS/NZS 2053.2 Colors:whiteand othercolorsuponrequest Length:accordingtocustomer'srequests
Advantages
⊚ Excellent non-conductive performance : The conduit has excellent non-conductive performance, high current breakdown voltage resistance. There's no electrical danger by using Liansu UPVC conduit, because it can resist 25 thousand volt without breakage.
⊚ Good compressure resistance : The conduit can be layed in the concrete with good compressureresistance.
⊚ Good fire resistance : The conduit has good combustion resistance.
⊚ Moist resistance, corrosion resistance : The conduit can resist moist,unaffected by electrical reactions caused by acids,bases, and oils that cause corrosioninmetals.
⊚ Anti-insect :
The conduit can avoid be bited by insects.
⊚ Easy to bend : Insect one spring into the pipe, then the pipe can be easily bent without heating.
⊚ Easy installation :
Use Liansu cement to connect the pipe and all kinds of accessories.
Applications
⊚ Protect and manage indoor electrical wiring.
NOTE:The thickness marked below only forreference.
| SAP No. (plain end/2.9M) | SAP No. (belled end/2.9M) | Size(mm) | Wall Thickness | PackQty |
| 8030050003 | 8030050876 | 16 | 1.5 | 35 |
| 8030050011 | 8030050877 | 20 | 1.8 | 25 |
| 8030050020 | 25 | 2.0 | 20 | |
| 8030050026 | 32 | 2.2 | 10 | |
| 8030050409 | 40 | 2.4 | 10 | |
| 8030050410 | 8030051052 | 50 | 2.6 | 5 |
| SAPNumber | Size(mm) | Length (m/coil) |
| 8030020306 | 16 | 100 |
| 8030020311 | 20 | 100 |
| 8030020320 | 25 | 100 |
| 8030020331 | 32 | 50 |
| 8030020335 | 40 | 50 |
| 8030020337 | 50 | 25 |
| SAP No. (plain end/2.9M) | SAP No. (belled end/2.9M) | Size(mm) | Wall Thickness | PackQty |
| 8030050055 | 8030050798 | 16 | 1.3 | 35 |
| 8030050068 | 8030050136 | 20 | 1.5 | 25 |
| 8030050080 | 8030050138 | 25 | 1.6 | 20 |
| 8030050090 | 8030050800 | 32 | 1.9 | 10 |
| 8030050101 | 8030050967 | 40 | 2.0 | 10 |
| 8030050110 | 8030050801 | 50 | 2.2 | 5 |
Note:
The Grade A and Grade B is the classification code according to the mechanical requirements under specifiedtests (resistance to compression,resistance to impact, collapse resistance etc.). GradeAisHeavy and Grade B is Medium according to IEC 61386-21,IEC61386-23.
Coupling
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020287 | 16 | 900 |
| 8030020288 | 20 | 500 |
| 8030020289 | 25 | 250 |
| 8030020290 | 32 | 120 |
| 8030020291 | 40 | 100 |
| 8030020292 | 50 | 72 |
| 8030020293 | 60 | 50 |
Male Adapter(forcorrugated conduit)ll
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020350 | 16 | 560 |
| 8030020351 | 20 | 350 |
| 8030020352 | 25 | 200 |
| 8030020353 | 32 | 140 |
Change Union (for corrugated conduit)
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020790 | 20 | 350 |
Reducer
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020270 | 20×16 | 600 |
| 8030020271 | 25×20 | 480 |
| 8030020272 | 32×20 | 264 |
| 8030020273 | 32×25 | 264 |
| 8030020274 | 40×25 | 170 |
| 8030020275 | 40×32 | 150 |
| 8030020276 | 50×32 | 100 |
| 8030020277 | 50×40 | 80 |
Flexible Reducer
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020155 | 20×16 | 600 |
| 8030020398 | 25×16 | |
| 8030020399 | 25×20 | |
| 8030020400 | 32×16 | |
| 8030020401 | 32×20 | |
| 8030020402 | 32×25 |
External Quick Connect (for corrugated conduit)
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021423 | 16 | |
| 8030021233 | 20 | |
| 8030021446 | 25 | |
| 8030021443 | 40 | |
| 8030021463 | 50 |
Water-sealed Flexible Coupling
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021251 | 20 | |
| 8030021252 | 25 | |
Corrugated Conduit/Conduit Change Union
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021456 | 16 | |
| 8030021424 | 20 | |
| 8030021452 | 25 |
QuickConnectionMaleAdapter(for corrugated conduit)
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021409 | 20 | |
| 8030021444 | 25 | |
45° Elbow
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021230 | 20 | 400 |
| 8030021231 | 25 | 200 |
| 8030021212 | 32 | 100 |
| 8030021213 | 40 | |
| 8030021471 | 50 |
Tee
90° Elbow
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020170 | 16 | 300 |
| 8030020171 | 20 | 200 |
| 8030020172 | 25 | 130 |
| 8030020173 | 32 | 70 |
| 8030020174 | 40 | 40 |
| 8030020175 | 50 | 25 |
| 8030020176 | 60 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020206 | 16 | 500 |
| 8030020207 | 20 | 320 |
| 8030020208 | 25 | 160 |
| 8030020209 | 32 | 90 |
| 8030020210 | 40 | 50 |
| 8030020211 | 50 | 35 |
| 8030020212 | 60 | 20 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020621 | 16 | 500 |
| 8030020202 | 20 | 250 |
| 8030020203 | 25 | 130 |
| 8030020204 | 32 | 60 |
| 8030020205 | 40 | 40 |
| 8030040024 | 50 | 25 |
Elbow with Cover
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020391 | 16 | 300 |
| 8030020221 | 20 | 200 |
| 8030020222 | 25 | 125 |
| 8030020223 | 32 | 60 |
| 8030020224 | 40 | 40 |
| 8030020225 | 50 | 25 |
ExtendedLongSweepBend
Tee with Cover
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021469 | 16 | |
| 8030021232 | 20 | |
| 8030021470 | 25 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020392 | 16 | 120 |
| 8030020185 | 20 | 80 |
| 8030020186 | 25 | 60 |
| 8030020187 | 32 | 30 |
| 8030020580 | 40 | 20 |
| 8030020581 | 50 | 11 |
Bending Elbow
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021401 | 16 | |
| 8030021402 | 20 | |
| 8030021294 | 25 | |
Assembling Audio Video Gang Box
1 Way Terminal Box (with cover)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020231 | 65×40/1/16 | 40 | 60 |
| 8030020232 | 65×40/1/20 | 40 | 60 |
| 8030020233 | 65×40/1/25 | 40 | 60 |
1 Way Deep Terminal Box (concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020112 | 65×65/1/16 | 65 | 30 |
| 8030020113 | 65×65/1/20 | 65 | 30 |
| 8030020114 | 65×65/1/25 | 65 | 30 |
| 8030020558 | 65×70/1/16 | 70 | 30 |
| 8030020378 | 65×70/1/20 | 70 | 30 |
| 8030020368 | 65×70/1/25 | 70 | 30 |
2 Way Through Box (with cover)
| SAP Number | Size(mm) | H | PCS/CTN |
| 8030020256 | 65×40/21/16 | 40 | 50 |
| 8030020257 | 65×40/21/20 | 40 | 50 |
| 8030020258 | 65x40/21/25 | 40 | 50 |
2 Way Deep Through Box(concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020267 | 65×65/21/16 | 65 | 30 |
| 8030020268 | 65×65/21/20 | 65 | 30 |
| 8030020269 | 65×65/21/25 | 65 | 30 |
| 8030020561 | 65×70/21/16 | 70 | 30 |
| 8030020380 | 65×70/21/20 | 70 | 30 |
| 8030020381 | 65×70/21/25 | 70 | 30 |
2 Way Angle Box (with cover)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020239 | 65×40/2L/16 | 40 | 50 |
| 8030020240 | 65×40/2L/20 | 40 | 50 |
| 8030020241 | 65×40/2L/25 | 40 | 50 |
2 Way Deep Angle Box (concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020115 | 65×65/2L/16 | 65 | 30 |
| 8030020116 | 65×65/2L/20 | 65 | 30 |
| 8030020117 | 65×65/2L/25 | 65 | 25 |
| 8030020560 | 65×70/2L/16 | 70 | 30 |
| 8030020379 | 65×70/2L/20 | 70 | 30 |
| 8030020367 | 65×70/2L/25 | 70 | 25 |
3 Way Tee Box (with cover)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020191 | 65×40/3/16 | 40 | 50 |
| 8030020192 | 65×40/3/20 | 40 | 50 |
| 8030020193 | 65×40/3/25 | 40 | 40 |
3 Way Deep Tee Box (concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020167 | 65×65/3/16 | 65 | 30 |
| 8030020168 | 65×65/3/20 | 65 | 30 |
| 8030020169 | 65×65/3/25 | 65 | 25 |
| 8030020559 | 65×70/3/16 | 70 | 30 |
| 8030020382 | 65×70/3/20 | 70 | 30 |
| 8030020383 | 65×70/3/25 | 70 | 25 |
4 Way Cross Box (with cover)
| SAP Number | Size(mm) | H | PCS/CTN |
| 8030020247 | 65x40/4/16 | 40 | 50 |
| 8030020248 | 65×40/4/20 | 40 | 40 |
| 8030020249 | 65×40/4/25 | 40 | 35 |
4 Way Deep Cross Box (concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020118 | 65×65/4/16 | 65 | 25 |
| 8030020119 | 65×65/4/20 | 65 | 25 |
| 8030020120 | 65×65/4/25 | 65 | 25 |
| 8030020121 | 65×70/4/16 | 70 | 25 |
| 8030020122 | 65×70/4/20 | 70 | 25 |
| 8030020123 | 65×70/4/25 | 70 | 25 |
GangBox (with active foot, concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020044 | 77×77/20 | 38 | 40 |
| 8030020046 | 77×77/2025 | 38 | 40 |
8030020045 77×77/20 48 35
8030020047 77×77/2025 48 35
(with active foot, concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020062 | 77×77/20 | 56 | 30 |
| 8030020064 | 77×77/2025 | 56 | 30 |
8030020063 77×77/20 70 30
8030020065 77×77/20 25 70 30
(with active foot, concealed installation)
| SAP Number | Size(mm) | H PCS/CTN | |
| 8030020052 | 164×77/16×22025 | 38 | 22 |
(with active foot, concealed installation)
(with active foot,concealed installation)
| SAP Number | Size(mm) | H PCS/CTN |
| 8030020055 | 141×80/20 | 50 22 |
Deeper Assembling Gang Box (through reinforcement type, concealed installation)
| SAPNumber | Size(mm) | H PCS/CTN |
| 8030020066 | 81×81/20 50 | 35 |
| 8030021130 | 81x81/25 50 | 35 |
| 8030021293 | 81×81/Φ20Φ2550 | 35 |
| 8030021299 | 81×81/Φ20 60 | |
| 8030021301 | 81x81/Φ25 60 | |
| 8030021300 | 81×81/Φ20Φ2560 |
Gang Box (with active foot, conncealed installation)
SAP Number Size(mm) H PCS/CTN
8030020053255x75/20×225x250 12
Insert Reinforce Lengthened Assembling Gang Box (through reinforcement type,conncealed installation)
| SAP Number | Size(mm) | H | PCS/CTN |
| 8030020917 | 77×77/20 | 60 | 32 |
| 8030020864 | 77×77/20 | 70 | 27 |
| 8030020865 | 77×77/2025 | 70 | 27 |
| 8030020866 | 77×77/25 | 70 | 27 |
Gang Box (surface installation)
| SAPNumber | Size(mm) | 工 | PCS/CTN |
| 8030020071 | 86×86/2025 | 40 | 40 |
| 8030021168 | 86×86/20 | 40 | 40 |
| 8030020070 | 86×86/20 | 54 | 30 |
| 8030020072 | 86×86/2025 | 54 | 30 |
Gang Box(surface installation)
TransferFrame
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020388 | 77×77 | 22 | 91 |
GangBox
(through reinforcement type, conncealed installation)
| SAPNumber | ()az | 工 PCS/CTN |
| 8030020056 | 77×77/20 | 50 37 |
| 8030020057 | 77×77/20 | 60 32 |
| 8030020058 | 77×77/20 | 70 28 |
| 8030021176 | 77×77/25 | 70 28 |
| 8030020562 | 77×77/2025 | 50 37 |
| 8030020059 | 77×77/2025 | 60 32 |
| 8030020060 | 77×77/2025 | 70 28 |
| 8030021590 | 77×77/Φ20 | 105 |
| 8030021591 | 77×77/Φ20Φ25 | 105 |
GangBox (through reinforcement type, concealed installation)
| SAPNumber | Size(mm) | 工 | PCS/CTN |
| 8030020618 | 77×77/20 | 70 | 28 |
| 8030020619 | 77×77/2025 | 70 | 28 |
| 8030020918 | 77×77/20 | 60 | 32 |
| 8030020919 | 77×77/2025 | 60 | 32 |
Gang Box (typy Ⅲ, concealed installation)
GangBox (through reinforcement type, concealed installation)
| SAPNumber | Size(mm) | H | PCS/ CTN |
| 8030020620 | 141×80/20 | 50 | 22 |
| 8030020663 | 164×77/162025 | 38 | 22 |
| 8030020664 | 164×77/2025 | 50 | 18 |
Deeper Assembling Gang Box (typy Ⅲ, concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030021094 | 81×81/2020 | 50 | |
| 8030021095 | 81×81/2025 | 50 | |
| 8030021109 | 81×81/2020 | 45 | |
| 8030021551 | 81x81/Φ20Φ20 | 60 | |
| 8030021285 | 81×81/Φ20Φ25 | 60 | |
| 8030021558 | 81x81/Φ20Φ25 | 70 |
GangBox (with metal feet, concealed installation)
| SAPNumber | Size(mm) | 工 | PCS/CTN |
| 8030021083 | 77×77 | 50 | |
| 8030020867 | 100×65 | 50 | |
| 8030021528 | 135×65 | 50 | |
| 8030021529 | 181×65 | 50 |
Rib-piercing Deeper Assembling Gang Box (through reinforcement type, concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030021235 | 77×77/20 | 70 | 24 |
| 8030021236 | 77×77/2025 | 70 | 24 |
| 8030021237 | 77×77/25 | 70 | 24 |
Rib-piercing Lengthened Assembling Gang Box (through reinforcement type, conncealed installation)
| SAPNumber | Size(mm) | H | PCS/ CTN |
| 8030021548 | 77×77/Φ20 | 70 | |
| 8030021549 | 77×77/Φ20Φ25 | 70 | |
| 8030021550 | 77×77/Φ25 | 70 |
Assembling Gang Box (typy Ⅲ-1, concealed installation)
| SAPNumber | Size(mm) | 工 | PCS/CTN |
| 8030021210 | 86×86/2025 | 50 | |
Assembling Gang Box (with active foot)
SAPNumber Size(mm) H PCS/CTN 8030021422 81x81/Φ20 40
Positioning Assembly Gang Box (through reinforcement type, conncealed installation)
| SAPNumber | Size(mm) | H PCS/CTN |
| 8030021397 | 81×81/Φ20 | 70 |
| 8030021398 | 81×81/Φ20Φ25 | 70 |
| 8030021399 | 81×81/Φ25 | 70 |
| 8030021552 | 81×81 | 70 |
Water-sealed Gang Box (through reinforcement type
| SAPNumber | Size(mm) | H PCS/CTN |
| 8030021554 | 81×81/Φ20 | 50 |
| 8030021555 | 81×81/Φ20Φ25 | 50 |
| 8030021556 | 81×81/Φ20 | 60 |
| 8030021557 | 81x81/Φ20Φ25 | 60 |
| SAP Number | Size(mm) | H PCS/CTN |
| 8030021592 | 77×77/Φ20 | 70 |
| 8030021593 | 77×77/Φ20Φ25 | 70 |
| 8030021594 | 77×77/Φ25 | 70 |
| 8030021595 | 77×77 | 70 |
| 8030021607 | 77×77/Φ201l | 70 |
| 8030021608 | 77×77/Φ20Φ2511 | 70 |
| 8030021635 | 77×77/Φ2511 | 70 |
GangBox (through reinforcement type, with 8 active feet, concealed installation)
| SAPNumber | Size(mm) | H | PCS/CTN |
| 8030020661 | 77×77/20 | 70 | 38 |
| 8030020662 | 77×77/25 | 70 | 38 |
| 8030020763 | 77×77/20 | 60 | 40 |
| 8030020764 | 77×77/25 | 60 | 40 |
Rib-piercing Gang Box (through reinforcement type, with 8activefeet,concealed installation)
| SAPNumber | Size(mm) | 工 | PCS/CTN |
| 8030020041 | 77×77/20 | 50 | 45 |
| 8030020042 | 77×77/20 | 60 | 40 |
| 8030020043 | 77×77/20 | 70 | 38 |
| 8030020557 | 77×77/2025 | 70 | 38 |
| 8030020851 | 77×77/25 | 70 | 38 |
Gang Box Cover
Size:75×75\~86×86
| SAP Number | Size(mm) | PCS/CTN |
| 8030020387 | 75×75 | 340 |
| 8030020920 | 77×77 | 250 |
| 8030020369 | 86x86 | 230 |
| 8030020384 | 100×75 | |
| 8030020385 | 147×86 | 160 |
| 8030020386 | 164×77 | 160 |
| 8030020733 | 172×86 |
BoxCover
| SAP Number | Size(mm) | PCS/CTN |
| 8030020255 | 65 | 600 |
Box Cover (with 8 active feets)
Gang Box (1 ways, concealed installation)
Gang Box(2ways,concealedinstallation)
| Gang Box(4 4ways,concealed installation) | |||
| SAPNumber | Size(mm) | H PCS/CTN | |
| 8030021596 | 81×81/Φ20 | 70 | |
| 8030021624 | 81×81/Φ25 | 70 | |
| Gang Box (2 ways, concealed installation) | |||
| SAPNumber | Size(mm) | H PCS/CTN | |
| 8030021585 | 81x81/Φ20 | 70 | |
| 8030021599 | 81x81/Φ25 | 70 | |
Clamp
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020126 | 16 | 2000 |
| 8030020127 | 20 | 1000 |
| 8030020128 | 25 | 900 |
| 8030020129 | 32 | 500 |
| 8030020130 | 40 | 300 |
| 8030020131 | 50 | 210 |
Assembling Clamp
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020420 | 16 | 1800 |
| 8030020421 | 20 | 1000 |
| 8030020422 | 25 | 1000 |
| 8030020423 | 32 | 500 |
U Style Clamp
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021111 | 20 | 900 |
| 8030021112 | 25 | 700 |
U Style Clamp
| SAP Number | Size(mm) | PCS/CTN |
| 8030020593 | 16 | 2000 |
| 8030020594 | 20 | 1500 |
| 8030020595 | 25 | 1000 |
| 8030020596 | 32 | 500 |
Double U Clamp
Plug
| SAP Number | Size(mm) | PCS/CTN |
| 8030020158 | 16 | 3500 |
| 8030020159 | 20 | 3000 |
| 8030020160 | 25 | 2000 |
All-purpose Plug
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021524 | 16 | |
| 8030021525 | 20 | |
| 8030021526 | 25 |
Hook Clamp
| SAPNumber | Size(mm) | PCS/CTN | |
| 8030021494 | 16 | ||
| 8030021194 | 20 | ||
| 8030021195 | 25 | ||
| 8030021211 | 32 | ||
Side Clamp
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021542 | 16 | |
| 8030021543 | 20 | |
| 8030021544 | 25 | |
| 8030021545 | 32 | |
| 8030021546 | 40 | |
| 8030021547 | 50 |
Double U Side Clamp
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020736 | 16 | |
| 8030020737 | 20 | 900 |
| 8030020750 | 25 | 600 |
| 8030020751 | 32 | |
| 8030020752 | 40 | |
| 8030020753 | 50 |
| SAPNumber | Size(mm) | PCS/CTN | |
| 8030021633 | 16 | ||
| 8030021634 | 20 | ||
| 8030021622 | 25 | ||
| 8030021623 | 32 | ||
Color: white, grey and other colors upon request Length: according to customer's requests
Applications
⊚ Lay the wire inside and outside the stage, hotel, exhibition hall, classroom, computer room.
⊚ Lay the wire in the market, supermarket, writing building, the second decoration of the house.
⊚ Material warehouse, distributing center or other places with cars in and out.
⊚ The passage way in the workshop where there are forklifts come and across very often.
Installation Guid
⊚ Use special high sticky double-faced glue to fix the duct.
⊚ Clean the ground surface and the bottom surface of the duct before installation.
⊚ The width of the special high sticky double-faced glue should be 12\mathsf{mm}
⊚ For easy to connect with the accessories, when use the double-faced glue to connect with the duct, the vacancy of both ends of the duct with 20-30 size should be 60\mathsf{mm} at least; 100mm at least with 40-60 size of the duct; 150\mathsf{mm} at least with 70 size of the duct.For example, if the length of _{20x6} size of duct is 4\mathsf{m} then the length of the duct with double-faced glue should be 3.78m
Advantages
⊚ Attracting appearance,compressure resistance,fireresistance,non-conductive,corrosion resistance.
Wiring Duct
45° Elbow
| SAP Number (2m) | Size (mm) | PCS/CTN |
| 8030030001 | 20×6 | |
| 8030030002 | 30×8 | |
| 8030030003 | 40×9.5 | |
| 8030030004 | 50×11 | |
| 8030030005 | 60×13 | |
| 8030030006 | 70×15 |
| SAP Number | Size (mm) | PCS/CTN |
| 8030040037 | 20×6 | 400 |
| 8030040011 | 30×8 | 300 |
| 8030040006 | 40×9.5 | 200 |
| 8030040007 | 50×11 | 100 |
| 8030040019 | 60×13 | 100 |
| 8030040010 | 70×15 | 50 |
Tee
Adapter
| SAPNumber | Size (mm) | PCS/CTN |
| 8030040001 | 20×6 | 400 |
| 8030040012 | 30×8 | 300 |
| 8030040002 | 40×9.5 | 100 |
| 8030040013 | 50×11 | 60 |
| 8030040014 | 60×13 | 50 |
| 8030040015 | 70×15 | 40 |
| SAPNumber | Size (mm) | PCS/CTN |
| 8030040008 | 20×6 | 400 |
| 8030040020 | 30×8 | 300 |
| 8030040009 | 40×9.5 | 230 |
| 8030040021 | 50×11 | 200 |
| 8030040022 | 60×13 | 100 |
| 8030040023 | 70×15 | 100 |
90° Elbow
| SAP Number | Size (mm) | PCS/CTN |
| 8030040003 | 20×6 | 400 |
| 8030040016 | 30×8 | 300 |
| 8030040004 | 40×9.5 | 200 |
| 8030040005 | 50×11 | 100 |
| 8030040017 | 60×13 | 60 |
| 8030040018 | 70×15 | 50 |
| SAPNumber | Size (mm) | PCS/CTN |
| 8030040025 | 60×13→40×9.5 | |
| 8030040026 | 60×13→50×11 | |
| 8030040027 | 70×15→40×9.5 | |
| 8030040028 | 70×15→50×11 | |
| 8030040032 | 70×15→60×13 | |
| 90°InwardE Elbow(separable) | ||
| SAPNumber | Size (mm) PCS/CTN | |
| 8030040034 | 20×6 | |
Cross (separable)
| End Cap (separable) | ||
| SAPNumber Size (mm) | PCS/CTN | |
| 8030040036 | 50×11 | |
Standard: IEC 1084-2-1, IEC 61084-2-1 Colors: white and other colors upon request Length: according to customer's requests
Advantages
⊚ Non-conductive : Good insulation, able to resist 25kv voltage, assuring a safesystem.
⊚ Fire resistance: Self-extinguishing, do not support combustion.
⊚ Corrosionresistance: Resistant to acids,bases and salts, assuring a lower maintenancecostand a longerperformancelife.
⊚ Impact strength : Resistant to compression and impact, no cracks occur due to screwing.
⊚ Attracting appearance : Even color, good appearance, suitable for indoor installation.
⊚ Easy to install : Light weight, easy to transport, handle and install.
⊚ Good breakage resistance : The trunking won't be broke when peg the nail on it.
Applications
⊚ Protect and manage indoor electrical wiring
| SAP Number (2.9M) | Size(mm) | W | H | PackQty |
| 8030010280 | 20×10 | 20 | 10 | 30 |
| 8030010281 | 24×14 | 24 | 14 | 25 |
| 8030010514 | 30×15 | 30 | 15 | 20 |
| 8030010012 | 39×19 | 39 | 19 | 15 |
| 8030010017 | 50×25 | 50 | 25 | 10 |
| 8030010515 | 59×22 | 59 | 22 | 10 |
| 8030010024 | 60×40 | 60 | 40 | 6 |
| 8030010369 | 80×40 | 80 | 40 | 3 |
| 8030010412 | 80×50 | 80 | 50 | |
| 8030010533 | 99×27 | 99 | 27 | 5 |
| 8030010316 | 99×40 | 99 | 40 | 3 |
| 8030010516 | 99×60 | 99 | 60 | 2 |
| 8030010487 | 150×100 | 150 | 100 | 1 |
| 200×100 | 200 | 100 | 1 |
| SAP Number (2.9M) | Size(mm) | W | 工 | Pack Qty |
| 8030010491 | 20×10 | 20 | 10 | 30 |
| 8030010044 | 24 ×14 | 24 | 14 | 25 |
| 8030010397 | 30×15 | 30 | 15 | 20 |
| 8030010052 | 39×19 | 39 | 19 | 15 |
| 8030010291 | 50×25 | 50 | 25 | 10 |
| 8030010062 | 59×22 | 59 | 22 | 10 |
| 8030010067 | 60×40 | 60 | 40 | 6 |
| 8030010071 | 80×40 | 80 | 40 | 3 |
| 99×27 | 99 | 27 | 5 | |
| 8030010080 | 99×40 | 99 | 40 | 3 |
| 8030010509 | 99×60 | 99 | 60 | 2 |
| 150×100 | 150 | 100 | 1 | |
| 200×100 | 200 | 100 | 1 |
Coupling
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020079 | 24×14 | 750 |
| 8030020600 | 30×15 | 720 |
| 8030020080 | 39×19 | 500 |
| 8030020635 | 50×25 | 300 |
| 8030020081 | 59×22 | 270 |
| 8030020082 | 60×40 | 120 |
| 8030020799 | 80×40 | |
| 8030020800 | 80×50 | 120 |
| 8030020084 | 99×27 | 110 |
| 8030020085 | 99×40 | 68 |
| 8030020086 | 99×60 | |
| 8030020393 | 150×100 | 45 |
| 10 | ||
| 8030020372 | 200×100 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020001 | 39×19/24×14 | |
| 8030020631 | 50×25/39×19 | |
| 8030020002 | 59×22/39×19 | 230 |
| 8030020632 | 60×40/39×19 | |
| 8030020613 | 60×40/50×25 | |
| 8030020603 | 99×27/50×25 | |
| 8030020003 | 99×27/59×22 | |
| 8030020859 | 99×27/60×40 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020004 | 20×10 | 1000 |
| 8030020005 | 24×14 | 640 |
| 8030020624 | 30×15 | 360 |
| 8030020006 | 39×19 | 250 |
| 8030020407 | 50×25 | 120 |
| 8030020007 | 59×22 | 96 |
| 8030020008 | 60×40 | 66 |
| 8030020009 | 80×40 | 38 |
| 8030020757 | 80×50 | |
| 8030020011 | 99×27 | 44 |
| 8030020012 | 99×40 | 32 |
| 8030020013 | 99×60 | 20 |
| 8030021295 | 100×100 | 12 |
| 8030020404 | 150×100 | 2 |
| 8030020370 | 200×100 |
External Angle
| SAP Number | Size(mm) | PCS/CTN |
| 8030020026 | 20×10 | 700 |
| 8030020027 | 24×14 | 400 |
| 8030020802 | 30×15 | |
| 8030020028 | 39×19 | 180 |
| 8030020029 | 59×22 | 120 |
| 8030020030 | 60×40 | 80 |
| 8030020031 | 80×40 | 50 |
| 8030020801 | 80×50 | 25 |
| 8030020033 | 99×27 | 45 |
| 8030020034 | 99×40 | 30 |
| 8030020035 | 99×60 | 18 |
| 8030021296 | 100×100 | 12 |
| 8030020371 | 150×100 | 4 |
| 8030020025 | 200×100 | 4 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020038 | 24×14 | 288 |
| 8030020039 | 39×19 | 115 |
| 8030020711 | 50×25 | 70 |
| 8030020040 | 59×22 | 50 |
| 8030020582 | 60×40 | 30 |
Flat Tee
| SAPNumber | Size(mm) PCS/CTN |
| 8030020088 20×10 | 492 |
| 8030020089 24×14 | 336 |
| 8030020611 30×15 | 240 |
| 8030020090 39×19 | 180 |
| 8030020623 50×25 | 90 |
| 8030020091 59×22 | 72 |
| 8030020092 60×40 | 50 |
| 8030020093 80×40 | 36 |
| 8030020095 99×27 | 32 |
| 8030020096 99×40 | 24 |
| 8030020097 99×60 | 16 |
| 8030021197 100×100 | |
| 8030020373 150×100 | 2 |
| 8030020087 | 200×100 |
Stop End
Note : 80x40, 80x50 reserved hole.
| SAPNumber | Size(mm) PCS/CTN |
| 8030020105 24×14 | 500 |
| 8030020636 30×15 | |
| 8030020106 39×19 | 450 |
| 8030020612 50×25 | 220 |
| 8030020107 59×22 | 200 |
| 8030020374 60×40 | 84 |
| 8030020728 80×40 | |
| 8030020714 80×50 | 50 |
| 8030020109 99×27 | 75 |
| 8030020110 99×40 | 50 |
| 8030020111 99×60 | 30 |
| 8030021198 100×100 | |
| 8030020585 150×100 | 10 |
| 200×100 | |
| 8030020642 | 6 |
Middle-to-Big Tee
Middle-to-Small Tee
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020390 | 24×14 | |
| 8030020615 | 39×19 | |
| 8030020712 | 50×25 | |
| 8030020411 | 59×22 | |
| 8030020713 | 60×40 |
| SAPNumber | Size(mm) PCS/CTN |
| 8030020646 | 24×14/20×10 |
| 8030020647 | 30×15/24×14 |
| 8030020648 | 39×19/24×14 |
| 8030020690 | 39×19/30×15 |
| 8030020691 | 50×25/39×19 |
| 8030020744 | 59×22/39×19 |
| 8030020692 | 59×22/50×25 |
| 8030020770 | 60×40/50×25 |
| 8030020704 | 60×40/59×22 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020597 | 20×10 | |
| 8030020598 | 24×14 | |
| 8030020625 | 39×19 | |
| 8030020626 | 50×25 | |
| 8030020414 | 59×22 | |
| 8030020599 | 60×40 |
Middle-to-Big Angle Flat Tee
Left Flat Tee
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020874 | 20×10 | |
| 8030020412 | 24×14 | |
| 8030020627 | 30×15 | |
| 8030021118 | 39×19 |
| SAPNumber | Size(mm) PCS/CTN |
| 8030020705 | 20×10/24×14 |
| 8030020649 | 24×14/30×15 |
| 8030020706 | 24×14/39×19 |
| 8030020707 | 30×15/39×19 |
| 8030020681 | 39×19/50×25 |
| 8030020650 | 39×19/59×22 |
| 8030020708 | 50×25/59×22 |
| 8030020745 | 50×25/60×40 |
| 8030020709 | 59×22/60×40 |
Box-Style Flat Tee
Trunking Bridge
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020098 | 24×14 | |
| 8030020099 | 39×19 | |
| 8030020616 | 50×25 | |
| 8030020100 | 59×22 | |
| 8030020583 | 60×40 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020688 | 20×10 | |
| 8030020643 | 24×14 | |
| 8030020644 | 30×15 | |
| 8030020645 | 39×19 | |
| 8030020680 | 50×25 | |
| 8030020689 | 59×22 | |
| 8030021090 | 60×40 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020916 | 20×10 | |
| 8030020413 | 24×14 | |
| 8030020628 | 30×15 | |
| 8030020622 | 39×19 |
| SAPNumber | Size(mm) PCS/CTN |
| 8030020710 24×14 | |
| 8030020665 | 39×19 |
| 8030020666 | 50×25 |
| 8030020667 | 59×22 |
| 8030020668 | 60×40 |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020633 | 39×19/24×14 | |
| 8030020638 | 50×25/24×14 | |
| 8030020639 | 50×25/39×19 | |
| 8030020602 | 59×22/24×14 | |
| 8030020415 | 59×22/39×19 |
| SAPNumber | Size(mm) PCS/CTN |
| 8030020741 | 24×14 |
| 8030020742 | 39×19 |
| 8030020743 | 50×25 |
| 8030021223 | 59×22 |
| 8030021224 | 60×40 |
Box-style Internal Angle
| SAPNumber | Size(mm) PCS/CTN |
| 8030021097 | 24×14 |
| 8030021091 | 39×19 |
| 8030020771 | 50×25 |
| 8030021117 | 59×22 |
| 8030021092 | 60×40 |
Gang Box (with cover)
| SAPNumber | Size(mm) | Cover Diameter(mm) |
| 8030020729 | 80×40 | |
| 8030020730 | ||
| 8030020731 | ||
| 8030020715 | 80×50 | |
| 8030020716 | ||
| 8030020718 |
Coupling with hole
Bend through the wall
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021086 | 80×40 | |
| 8030021089 | 80×50 | |
Coupling through the wall
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021084 | 80×40 | |
| 8030021087 | 80×50 | |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030021085 | 80×40 | |
| 8030021088 | 80×50 | |
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020357 | 16 | 30 |
| 8030020362 | 20 | 20 |
| 8030020363 | 25 | 12 |
| 8030020375 | 32 | 8 |
| Cutter | |||
| SAPNumber | Size(mm) | PCS/CTN | |
| 8030020356 | 16-40 | ||
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020358 | 16 | 30 |
| 8030020361 | 20 | 20 |
| 8030020364 | 25 | 12 |
| 8030020376 | 32 | 8 |
Bending Spring (for Grade C Conduit)
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020359 | 16 | 30 |
| 8030020360 | 20 | 20 |
| 8030020365 | 25 | 12 |
| 8030020377 | 32 | 8 |
High Sticky Double-Faced Glue
Color: white
Length: according to customer's requests
Advantages
⊚ Perfect insulating performance It can withstand 2,500 electric voltages without the risk of leakage and electrocution.
⊚ Corrosion resistance and anti-insect It rarely reacts against general acids or bases,with no damage by insect.
⊚ Excellent fire-proof properties
The fire can go out once the trunk leave the flame, avoiding thespreading of flame.Dueto theweak conductiveperformanceforheating,the trunkcan protect the circuit and delay the operation of appliance control system whenfire happens,so that people can be evacuatedfromfieldoffire.
⊚ Age resistance
Advanced formula and process reduce the risk of color change due to Uv.
⊚ Simple assembly
Fix the trunkin bottompart with screw on wall without groove and plastering.Put the electricwireinto trunking and then cover the wire with top part of trunking. Theinstallation canbefinished atonce.
⊚ Convenience
Special lock joint is adopted so that the close/open operationiseasy.Theweight of trunking isverylight which is helpful to disassembly and reassembly.
Performances
| Item | Trunking | Trunking Fittings | |
| Mechanical Properties | Bending after Load | DA≤H/10,DA≤10mm DB≤W/10,DB≤10mm | Noseparationbetween trunking and fittings |
| Impact Resistance | No breakage or split | No breakage or split | |
| Foreign Load | No detachmentwithframe | ||
| Heat Resistance | ≤2.0mm | ||
| Oxygen Index | Ol≥32 | Ol≥32 | |
| Burning Properties | Parallel Burning | Grade I | Grade I |
| Vertical Burning | FV-0 | FV-0 | |
| Smoke Density Rating | SDR≤75 | SDR≤75 | |
| Voltage Resistance | 1minNopenetration | 1min No penetration | |
| Electric Properties | |||
| Insulating Resistance | R≥1.0×10Q | R≥1.0×10Ω | |
Applications
Theversatiletrunkingismainlyintendedforsurface distribution projects as the protection for wire, telephone wiring,TVcables,Internetcables.Itcanbeapplied tothe building, hospital, mall, hotel, workshop, etc.
■Trunking Size
Standard:QB/T 1614-2000
| SAPNumber (4M) | Size (mm) | WallThickness (mm) | W (Width) | H (Height) | PCS/CTN |
| 8030010179 | 105×50 | 2.5 | 105 | 50 |
Flame-retardant insulated PVC multi-function trunking (with divider)
| SAPNumber (4M) | Size (mm) | WallThickness (mm) | W (Width) | H (Height) | PCS/CTN |
| 8030010522 | 105x50 | 2.5 | 105 | 50 |
| FlatAngle | |||
| SAPNumber | Size(mm) | PCS/CTN | |
| 8030020588 | 105×50 | 24 | |
| FlatTee | |||
| SAPNumber | Size(mm) | PCS/CTN | |
| 8030020586 | 105×50 | 18 | |
| FlatFixedFoot | |||
| SAPNumber | Size(mm) | PCS/CTN | |
| 8030020592 | 105×50 | 1000 | |
Flat Internal Angle
| FlatStop End | |||
| SAPNumber | Size(mm) | PCS/CTN | |
| 8030020590 | 105×50 | 60 | |
InstallationGuideof PVC Multifunctional Trunking and Fittings
InstallationInstrument
\circled{1} Panel socket \circled{2} Screwdriver (Cross, Straight) \circled{3} Reel ruler Tools: \circled{4} Straight ruler \circled{5} Handsaw \circled{6} Marking pen
For example (installation for parallel two panel-sockets)
\circled{1} Take screwdriver to the position showed in Fig 1 \circled{3} Put screwdriver between cap and bottom base, slip the (keep screwdriver close as possible as the lock joint on cap) ,nccrewdriver and open the cap.
then pry the joint upwardly so as to detach it. With the previous
method,you can separate the lock joint on the other side.
\circled{2} Position screwdriver between trunking's cap and lock on bottom base, ply the joint upwardly and the lock joint can be detached.The same performance can be applied to detachment of lock joint on the other side.
InstallationGuideof PVC Multifunctional Trunking and Fittings
\circleddash Design circuit and connect the panel socket, then fix the trunking base(if fixed on wall, trunking can be screwed onbottompart).Theconnectionbetween trunking bases can take related fittings, which is referrec to demonstration of trunking connected to fittings.
⊚ Fix position foot. Two position feet should be installed for each panel. During installation,the buckle on the side of position foot must be buttoned up on the lock position on trunking base.
\circled{3} When more than one panel sockets are installed, a capof 10\mathsf{mm} should be fixed between each two panels. Draw a straight line on the place 10\mathsf{mm} awayfrom terminal with marking pen.
\circledast Cut the marking line with handsaw.There should be no burr or dirty on the cutting cross section.
\circled{5} Fix cap. The distance between two caps should be 75-80mm when installation.
\circled{6} Fix panel.Attention should be paid that the side of panel should be pressed on the cap.One panel should be fixed before the screw is tightened.
⑦ Fix the other panel, then tighten screw to the extreme.
\circled{8} The demonstration of installation comes to end.
Advantages
Good Decoration Effect :
The air-conditionduct designed by industrycannot only solvethephenomenonthattheairconditioningrefrigerant pipeishanging outdoors atwill,disorderly andunbeautiful, butalsoplaytheroleof aestheticcoordinationwiththe externaldecorationstructureofmodernhouse.
Protective Refrigerating Pipe :
The air-condition duct is made of light-proof and antiultraviolet(Uv) radiation,impact-resistant,tensile-resistant and anti-aging materials, so as to protect the refrigerant pipe from being exposed by the wind, the rain and the sunlight. The refrigerant pipe canbe used for more than 20yearsatnormaltemperature(or -40~°\subset to +\ 60\ °C) and the design life of the air conditioner is exceeded.
Prevent Refrigerant Leakage :
The supporting point of suspended refrigerant pipe is on two bellmouth, the stress is concentrated, and cracks are easily generated after frequent shaking, resulting in leakage of refrigerant medium. After using the air-condition duct, it can prevent the shaking of the refrigerant pipe, prevent theleakage of the refrigerant medium andextend the servicelifeoftheairconditioner.
Eco-friendly and Energy Saving :
The air-condition duct can better protect refrigerant pipe andheatpreservationmaterial,highresistance to ultraviolet, radiationheat,heat conduction, convective heat and other externalfactorsonrefrigerantpipeandthermalinsulation materials, energy saving and electricity saving.
Material Characteristics :
HighstrengthPVC-Umaterials with flame retardant and insulationhave good wear resistance,hightemperature resistance, oil resistance,inhibition of algae and bacteria growth,impermeability and UVradiationresistance,antistatic, anti-impact, tensile resistance, aging resistance and other properties.
Applications
Installation and protection of air conditioning refrigerant pipes, drainage pipes and power lines under thefollowing 5P andbelow 5Pin enterprises, families and publicplaces
90° Elbow
| SAP Number(2m) | SAP Number(4m) | Size(mm) | Wall Thickness PCS/CTN |
| 8030050512 | 8030050742 | 70×56 | 1.5 |
| 8030050517 | 8030050743 | 80×65 | 1.7 |
| 8030050518 | 8030050744 | 100×70 | 2.0 |
90° Outside Corner
| SAPNumber | Size(mm) PCS/CTN |
| 8030020765 | 70×56 |
| 8030020773 | 80×65 |
| 8030020740 | 100×70 |
Coupling
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020724 | 70×56 | |
| 8030020725 | 80×65 | |
| 8030020685 | 100×70 |
90° Inside Corner
| SAPNumber | Size(mm) PCS/CTN |
| 8030020746 70×56 | |
| 8030020772 80×65 | |
| 8030020684 100×70 |
45° Elbow
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020758 | 70×56 | |
| 8030020769 | 80×65 | |
| 8030020683 | 100×70 |
Ceiling-hole Cover
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020686 | 70×56 | |
| 8030020768 | 80×65 | |
| 8030020785 | 100×70 |
45° Outside Corner
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020726 | 70×56 | |
| 8030020727 | 80×65 | |
| 8030020732 | 100×70 |
Wall-hole Cover
| SAPNumber | Size(mm) PCS/CTN |
| 8030020738 | 70×56 |
| 8030020747 | 80×65 |
| 8030020739 | 100×70 |
45° Inside Corner
| SAPNumber | Size(mm) | PCS/CTN |
| 8030020682 | 70×56 | |
| 8030020767 | 80×65 | |
| 8030020760 | 100×70 | |
Product introduction
Flame-retardant insulated PVC triangular trunking: using unleaded formula PVC material, which is different from ordinary square trunking. The triangular trunking has a novel appearance and a triangular cross section. One side is curved, and it is divided into an upper cover and a base. This part is suitable for ceilings, walls and corners on the floor, etc. The products are mainly used in installation projects such as building decoration projects,home hydropower project, building fire protection, telecommunications and electricity, and play a role in protection and electrical protection. It has the characteristics of strong insulation, environmental protection and beautiful appearance, economy, convenient wiring, neat wiring, reliable installation, and easy to find, repair and exchangelines.
Standard: Performance refer to QBT 1614-2008 flame-retardant insulated PVC conduit and fitings Colors: White,various color patterns and embossed triangle trunking can be customized according to customerneeds.
Advantages
1.The triangular belt arc structure is suitable for use in corners and ceilings, saving space.
2. Shaped like plaster line, can be used for ceiling modification, beautiful appearance.
3. The trunking base and the cover are snap-connected for easy disassembly and assembly,
and the trunking and fittings are connected by quick plugs,which is convenient forinstallation.
4. Adopt calcium-zinc formula, no lead, environmental protection and pollution-free.
Applied Range
⊚ Home fire protection, telecommunications power installation and other projects.
⊚ Home HydropowerProject; ⊚ Building Decoration Project;
| Flame-retardant insulatedPVC triangle trunking | ||||
| SAP Number(2m) | Size(mm) | W | H | PCS/CTN |
| 8030010537 | 20×20 | 30.8 | 17.8 | |
| 8030010580 | 30×30 | 45.6 | 28 | |
CapacityReference: 20x20 size triangle trunking can place 8 pcs CAT-5.
Note:Thelength of the pipeis 2m or4m, or other length upon request.
CapacityReference: 40x40 size triangle trunking can place 38 pcs CAT-5.
Capacity Reference: 30x30 size triangle trunking can place 20 pcs CAT-5.
Couple
90° Inner CornerElbow
Reducer
| SAPNumber | Size(mm) | PCS/CTN |
| 8030120005 | 20×20 | |
| 8030120009 | 30×30 |
90° OuterElbow
Reducer
StopEnd
Reducer
| SAPNumber | Size(mm) | PCS/CTN |
| 8030120003 | 20×20 | |
| 8030120012 | 30×30 | |
CE Certification for PVC Conduit and Fittings Comply with EN 61386-1, EN 61386-21, EN61386-23,IEC61084-1,IEC61084-2-1.
Certificate of Compliance
No.0B170531.GLTUC88 Test Reports no.SCC(17)-50005A-25-10-LVD
Certificate's Holder:
Guangdong Liansu Technology Industrial Co., Ltd. Liansu Industrial Estate, Longjiang Town, Shunde Zone, FoshanCity,GuangdongProvince,China
Certification ECM Mark:
Product: Model(s):
PVC Conduit and Fittings, PVC Trunking and Fittings
| PVCConduitandFittings | DN6-75mm |
| PVCTrunking andF Fittings | DN10-200mm |
Verification to:
Standard:
EN61386-1:2008,EN61386-21:2004+A11:2010, EN61386-23:2004+A11:2010,IEC61084-1:2017, IEC61084-2-1:2017
related to CEDirective(s): 2014/35/EU (Low Voltage)
Remark:Theproduct(s)hasbeenverifiedonavoluntarybasis.Theproduct(s)satisfiestherequirementsof theCertificationMarkofECM,inreferencetotheabovelistedStandard(s).TheaboveComplianceMark canbeaffixedontheproduct(s)accordinglytotheECMregulationaboutitsreleaseand itsuse.The regulationcanbefound atwww.entecerma.it.ThisCertificateofCompliancecanbecheckedforvalidity atwww.entecerma.it
This verificationdoesn't imply assessment of theproduction of theproduct(s).
We aftest that a TCF for theCE Marking process is in place.Whereas the ManufacturerisResponsibleto start theCEMarkingCericationProcedureandto performall thenecessaryactivitiesasrequiredbytheDirectivebeforeplacingthe CEMarkontheproduct(s).
Oceania WaterMark Certificate license for PVC Conduit and Fittings
GOST-Rlicenseapplied toRussiaandtheFiveCentralAsianCountries.
GOsT-RlicenseappliedtoRussiaandtheFiveCentralAsianCountries.
LESSO
CHINALESSOGROUPHOLDINGSLIMITED
(Stock Code:2128)