gmi
Product Catalogue
Behind efficient and effective electrical engineering solutions since 2008
GMI Products Included:
Get in touch with REAZ Australia today to see how
we can help your business increase efficiency and grow your bottom line with robust electrical engineering solutions today.
reaz
Unlock Peak Efficiency with Cutting-Edge Electrical Solutions.
Quality, Reliability, and Innovation
REAZ Australia's offering includes comprehensive electrical engineering services.
Comprising of experienced engineers with 25 years of industry expertise, our primary objective is to empower Drives & Automation Customers with globally recognized, high-quality products, while maintaining a strong focus on customerservice.
Full Local Engineering Support
30+Leading Global Products
Our Commitment to Your Business and a bit About Ours.
Along with our comprehensive range of products and services, we're here to help you build more efficient and effective operations.
Our aim is to empower drives and automation customers towards globally recognised and superior products to improve your bottom line and efficiency, because that's what really matters.
Integral to our core business philosophy of "We Care For Your Business," we compliment our Low Harmonic offering with Industrial Sensors, Hazardous Area Certified Range, RFID,
Vision, Network Solutions, Turnkey Engineering and a Level Of Servicecustomers demand.
Safety, performance, and reliability
OUR PRODUCTS, OURCOMMITMENT
GMInternationaldesigns,engineersand manufacturesacompleterangeof Intrinsically SafeandSIL 3certified devices that meet the stringestqualityrequirements,ensuring the highestproductionstandardsinIntrinsicallySafe applications.Ourproducts areused inautomation packages such asDCS-ESD-FGS-BMS-HIPPSPLC-SCADA,in several industrial sectors:Oil&Gas, Petrochemical, Pharmaceutical,Fertilizer,Mining, Food&Beverages,Marine.
SOCIAL RESPONSIBILITY
WedesignIntrinsicallySafeInstrumentsandSIL certified devices in order to prevent accidents and understand,manage and reduce risks forpeople andenvironment.
Customersatisfaction is the manner in whichwe demonstrateoursocialresponsibilitytocontribute tosustainabledevelopment,minimizingclimate impactandcreatingasafeandhealthyworking environment.
GMInternational hasobtainedSIL3Functional Safety Management approval by TUV according to IEC61508:2010standard.
CERTIFIED INTRINSICALLY SAFE PRODUCTS
Highest levels of safety
INTRINSICALLYSAFEPRODUCTS ANDIEC61508:2010SILCERTIFICATIONS
GM International products have been granted I.S.certificates from the most credited Notified Bodies in the world. Certificates are available for ATEX (Europe), IECEx (International), UL/FM (USA and Canada), EAC-EX (Russia CTU and Ukraine), NEPSI(China), PESO (India), TIIS (Japan), INMETRO (Brazil).All certificatesareavailablefordownloadfromourwebsite.
GM International offers awiderangeof productsthat havebeenproved tocomplywith themost severequalityandsafetyrequirements.IEC61508andIEC61511standardsrepresentamilestonein theprogressof industry in the achievement of highest levels of safety through the entire instrumented systemlifecycle.Themajorityofourproducts areSILcertified aswellas ourdesign,manufacturing and administrativefacilities(FSM);reportsandcertificatesfromTUVarealsoavailablefordownload.
gminternational.com
Summary
01
INTRINSICALLY SAFEISOLATORS
Page 06 (D5000 Series) Page 10 (D1000 Series)
SAFETY RELAYS
Page 14
GALVANIC ISOLATORS
04 POWER SUPPLIES Page 22
05 MULTIPLEXER SYSTEMS Page 30
06 SURGE ARRESTERS Page 34
07 HART INTERFACE SOLUTION Page38
08 TERMINATION BOARDS Page 40
FIELD
INDICATORS
Page 42
10 PRODUCT LIST Page 44
11 TRAINING& SERVICES Page50
SOFTWARES&ONLINETOOLS
Intrinsically Safe Isolators D5000 Series
IntrinsicallySafeGalvanicIsolatorsprovidethemostsimpleandcosteffectivemeans ofimplementingIntrinsicSafetyintoHazardousAreaapplications.
STRENGTHS
Reduced Foot Print: High Density: 6 mm per Channel Reduced Bulk Power Supply: Low Power Consumption Reduced Cooling Needs: Low Heat Dissipation · Higher Reliability In & Outdoor: Certified -40° to + 70° C·Higher Resilience to Surges: 2.5 KV Isolation · Data Guaranteed by 3rd Party: SIL 3 (2) TUV certification · Current & Valid Standard: CertifiedIEC61508:2010,Ed.2 Harsh Environment Resistance: G3 conformal coating Lower OwnershipCost:Certifiedfor20yearsoperation Reduced Spare Inventory: Universal Mounting (Stand Alone
DIN-Rail,Power Bus System and Termination Boards) Totally independent Dual Ch.: Dual Power Supply EasierTroubleshooting:Statusled indication
Structure
·High channel densityresulting from innovative circuit design using advanced surface mount components ·Single,dual or quad channel models ·Plug-in screw terminal blocks to secure wires upto 2.5\;mm2 ·Configuration components are easily accessedbyremovingthesidecover orviaconnectorfrontpanel
High Performance
GMInternationalD5oooseriesusesstate-of-the-artsolutionstoachievethehighest performanceforIntrinsicallySafe applications;guaranteedbyover15certification bodiesallovertheworld.
Fullyautomated assemblyline; 100% completeindividualtesting;Advancelowdissipation circuitry; Use of high temperature class components;Absence of electrolytic capacitors; G3conformal coating;Designed forvibration and highhumidity;arejustsome of the factors that guarantee a product with:
·High signal transfer accuracy and repeatability
·Verylowheat dissipation
·High reliability;SIL certified for 20 years useful life time
LONGERLIFETIME
WIDEFUNCTIONALITY
Capabilitytowithstand higher temperatures,improves the lifetime innormal conditions. ·Operating temperature certified
from -40°C to +70°C · Very high reliability in extreme environment applications ·G3 conformal coating ·Reducedcabinetdimensions, requirelessventilation
·More than25modulessuitableforSIL2andSIL3 applicationsaccordingtoIEC61508,IEC61511 .Three port galvanic isolation to eliminate noise, ground loopproblemsproviding IntrinsicSafety without a high integrity safety earth connection
· Line fault alarm detects open or short circuit of field cables
·Optional power bus DIN-Rail connector
·StandardTerminationBoard with custom connectorsforintegrationinto customizedBoards
·EMC Compatibility toEN61000-6-2,EN61000-6-4,
EN61326-1, EN61326-3-1 for safety system·Wide
range DC power supply (18-30 Vdc)·Certified for
Offshore andMaritimeapplications
gmi
Universal Mounting Units
The same device can be used in all applications to reduce spare inventory. ·DIN-rail stand-alone devices
·Standardandcustomizedterminationboards
·PowerbususingstandardTS35DIN-rail
Enhanced Power Bus Mounting
24 VdcPower Supply Voltage can be applied to the module by directly connecting to theplug-inTerminal Blockofeachmodule,orviathePowerBusSystem.Thesystem consists of standard DIN-Rail modules mounted on DIN-Rail Bus connectors.The maximum allowed powering capacityper trunk is8 A.It is alwayspossible toremove modules,withoutdisconnectingthebusconnectorwhichremainsattachedtotheDINRail.Communication bus is provided,on suitable models,to transmit via Modbus toDCS PLClogicsolver.CumulativeFaultAlarmindicationisprovidedontheBusconnection. D5202SredundantpowersupplyfeedmoduleprovidesSPSTRelaycontactfor commonandpowersupplyfaults;bothsupplyvoltages areindependently monitored. ·Redundant4Amppowersupplywithalarm
·Remotealarmindication
·Modules can be combined for additional redundancy
Special Dual Channel Feature
By using twototally independent PowerSupply circuitsforeach dual channel module, single channel integrity is maintained while drastically reducing space and installation cost.GMInternationalSIL3modulesoffertheindependenceoftwosinglechannels achieving anunprecedent6mmperchannel density.
There are no common componentshenceboth channels areSIL3certified and can be usedwithoutanyarchitecturallimitation.
Configuration Tools & Software
SWc5o90 software is designed to provide a PC user interface to configure suitable D5000,D5200 modules,via PPC5092 adapter. It allowstheusertoeasily:
·Readandwriteconfigurationparameterstotheunit
Storeandrestoredatatoandfromlocalharddriveforbackuporarchive
·Loadfactorydefaultconfigurations
MonitorrealtimeInputvaluesfordebugortest
·Print areport sheet containing configuration parameters and additional information
SWC5090 is freely distributed onour website:www.gminternational.com
PPC5092interface allows the configuration ofD5000,D5200modulesviaSWC5090 software.
Modules are supplied via USB and therefore donot need external powersupplywhile beingprogrammed.
PPC5092comeswithmini-USBcableand CD-Rom containing SWC5090 software.
Intrinsically Safe Isolators D1000 Series
IntrinsicSafetybarriersinterfacewithprocessmeasurementfielddevicessituatedina hazardous area of a plant.The GM International D1ooo Series IS Barrier is yet unsurpassedinreliabilityandperformance,providingthesimplestandcosteffective rangeof technologytoimplementIntrinsicSafetyintohazardous areasanddivisions. ThecompletelineofD10o0SeriesISBarriersissuitableforSIL3-SIL2applications accordingtoIEC61508,IEC61511.
STRENGTHS
ReducedFootPrint:High density,4 Channels · Full Application Coverage: All INs and OUTs available · Reduced Spare Inventory: Available as universal IN/OUT ·ReliableIndoor&Outdoor:Certified-40°to+60°C ResiliencetoSurge:1.5KVisolation ·SIL3(2)TuVcertification:Dataguaranteedby3rdParty Easy Installation:Din Rail &Power Bus mounting Easy Maintenance:Plug-in Enclosure Current&ValidStandard:CertifiedIEC61508:2010,Ed.2 Independent SIL certifiedDual Ch.:Dual PowerSupply
Structure
ENCLOSURE CHARACTERISTICS
·Highchannel densityresultingfrom innovativecircuitdesignusingadvanced surfacemountcomponents
·Single,dual or quad channel models
·Plug-in screw terminal blocks to secure wiresupto 2.5\:mm2
·Plug-in PCB can be removed for configurationoperations
Innovated and cost effective design for easy installation
TheD1ooo series has someinnovated designs tomakeinstallation and operationsafe andsimple.Someof thekeyfeaturesincluderemovableblue&greyTerminalsforeasy installation,apluginPCBwhichcanberemovedforeasyserviceandmaintenance operations.Configuration is via DIP switches allowing an easy and simplefield setup.
HIGHPERFORMANCE
·High signal transfer accuracy and repeatability
·Advanced circuitry provides lowheat dissipation,ensuring modules run cool despite their high functionality
·Low power consumption.
·SMD manufacturing for a long and reliablelife
·Wide operating temperaturerange (-20 /+60°C)
·2 modules(D1130-D1180) can be poweredfrom85to264Vac,50-400 Hz,orfrom 100 to350 Vdc
WIDEFUNCTIONALITY
·Wide range of Digital and Analog I/Os ·Relay contacts rated for 2 A to directlyswitch highloads Threeport galvanic isolation to eliminatenoise,groundloop problemsandtoprovideIntrinsic Safety without a high integrity safetyearth connection · Line fault alarm detects open or shortcircuitoffieldcables ·Optional Power Busenclosure
gmi
Packing
·Standard 35\;mm (TopHat)DIN-Rail ·High density package up to 176 I/O channels per meter of DIN-Rail ·Power Bus enclosure allows a significant reduction in cables,costs and space
Enhanced Power Bus Mounting
24 Vdcpower supplyvoltage canbe applied to the moduleby connecting thevoltage directlyto theplug-inTerminalBlockofeachmodule,orviaPowerBusSystem.When using the optional D1000PowerBus design,you cansupply12-24VDCdirectly tothe PowerBusSystemwhichhasamaximum allowedpower capacityof 8A.When the Power Busis used,supplycontacts on the terminalblocks are omittedto avoid accidentalshortcircuits.Noneedforacomplicated energizedrailsystem:theD10o0 usesasimpleenclosurechangetoallowtheuseofthePowerBusfeature.
Configuration Tools & Software
PPC1090PocketPortableConfigurator
ThePPC1090is a small and handyPocketPortableConfigurator suitable to program configurationparametersofD1oo0seriesmoduleslike:typeof inputSensors,input and output Ranges,Burnout conditions,High/LowAlarm mode,Relay NE/ND,AlarmTrip Point,HysteresisvalueandON/OFFAlarmdelays.TheConfiguratorispoweredbythe unitandcanbepluggedinwithoutdisconnectingthemodule.
PPC1092Serial Adapter
ThePPC1092adapterisneeded tointerface thePCwithD1000Seriesmodulesfora completeconfiguration of Input,Output andAlarmparameters.Thepackage includes necessary cables and a USB toRS-232Adapter;a CD-Romwith theSWC1090Software isalsoprovided.TheSWC1090canalsobedownloadedfromourwebsite.
SWC1090Software
TheSWC1090softwareisdesignedtoprovideaPCuserinterfacetoconfigure programmableD10o0modules.Iteasilyallows theuserto: ·Readandwriteconfigurationparameterstotheunits ·Storeandrestoredatatoandfromlocalharddriveforbackuporarchive
·Load factory defaultconfigurations ·MonitorInputvaluesviaUSB/COMport ·Print a report sheet containing configuration parametersandadditionalinformation TheSWC1090isfreelydownloadablefromourwebsite.
El1000ADPSeries Elcon Adapters
GM International offers continuity in the service of Elcon Instruments 10o0 series (nolongeravailablefromthemanufacturer).
Features
·ATEX,FM,FM-CCertifications
·InterchangeabilitywithallElcon10o0Seriesmodules
·Possibility toreplace obsolete modules without modifying wiring or connections
·DesignedtobeinstalledonexistingElconboards
·Identificationusing the same Elconpart-number
Safety Relays
Any time a relay is required and must be used in a SiF,it must conform and adhere to IEC61508andtotherelevantindustrystandard(i.e.61511).
Typicalcases:
· Controller cannot meet power requirement (V or A)
·Multiplicationofcontactsisrequired
·ControllerSafetyFunctionmustbeinverted
SIL certified relays are not used exclusively in Oil &Gas orPetrochemical industries; theyarealsoamustinmanyotherindustries:
·Railways
·Cars and Lift
·PowerDistribution
·Anytimeafailureoftherelaycancauseaseriousaccident
STRENGTHS
·ReducedFootPrint:HighDensity:12,5/22,5mm per Ch.
Full3rdPartyCertification:Coil-to-ContactSIL2/3TUV certified
·TrueReliability:CompatibletoDOCard LMPulses
·ReducedSpace/Eng.Costs:SmartLine/LoadMonitoring withtransparentFaultIndication(noadditionalcontacts)
·LowerOwnership/MaintenanceCost:T-proofTimes:10/20 years
·ReducedSpareInventory:Universal Mounting:DIN-Rail andTerminationBoards
·HigherReliabilityIn&Outdoor:Certified-40°to+70°C
·TotallyindependentDual Ch.:Dual circuits
·Full Application Coverage: Modules available with 5&10 Amps Contact,NE/ND application
·Harsh environment resistance: G3 conformal coating
Reliable switchingoperations:gold-plated relay contacts
Structure
·High channel densityresulting from innovative circuit design using advanced surface mount components ·Single,dualor quad channel models .Plug-in screw terminal blocks to secure wiresupto 2.5\:mm2 ·Configuration components are easily accessedbyremovingthesidecover or via connectorfront panel
Line & Load Monitoring
GMINTERNATIONALPATENTED DIAGNOSTICSFETATURES
·Works in all load conditions: ON/OFF ·Operates with OPEN/CLOSE Relay ·Some units are software configurable ·Suitablefor NE/ND,AC/DCLoads Transparent fault indicationto compatiblesystem
·Monitors:
· Load Supply Voltage ·Load Current ·Load resistance Earth leakage Internal Relay coils
SIL Certified Relays areused for critical loops where careful consideration should be giventoLine and LoadMonitoring.InaDe-energize toSafetyapplication awire/coil failure leads to a safety status.In an Energize to Safety application line failuresleads to a dangerousstatus.Inbothcasesfailure detectionisimportant,if notessential. Other diagnostics applications are monitoring the Load status to prevent spurious trips or toverifytheconditionoftheindividualcoil inaredundantcoilSOV.InF&Gsystemline diagnosticsisamustandregulatedbyNFPA72code.
Controlsystemdiagnosticcapabilitiesaredesignedtoworkwhennodeviceisinterposed between the control system and theload.lf a relay is placed in the loop,the diagnostic function stops at therelayinput circuit(coil).To perform linemonitoring from field device to controller, a SIL relay with built-in diagnostic circuit is required.GM International relays willperform diagnosticsof theload,wire,powersupply andinternal coilsinall operating conditions; providing an independent alarm contact as well as transparently transferring thefaultindicationtocompatibleDOcards.
gmi
Universal Mounting units
The same device canbe used in all applications toreduce spare inven
·DIN-rail stand-alone devices ·Standardandcustomizedterminationboards ·Powerbususing standard TS 35DIN-rail
Enhanced Power Bus Mounting
24 Vdc Power Supply Voltage can be applied to themodule by directly connecting to theplug-inTerminal Blockofeachmodule,orviathePowerBusSystem.Thesystem consistsof standardDIN-Rail modulesmounted onDIN-Rail Busconnectors.The maximum allowedpoweringcapacitypertrunkis8A.Itisalwayspossibletoremove modules,withoutdisconnecting thebusconnectorwhichremainsattachedtotheDINRail.Communicationbusisprovided,onsuitablemodels,to transmit via ModbustoDcS PLClogicsolver.CumulativeFaultAlarmindicationisprovidedontheBusconnection.
High Availability
Thanks to specific contact arrangement,GM International relay modules maintain higher level of safety while improving process availability.
·SIL 3: a single fault is not sufficient for a dangerous failure ·Availability: a single fault is not sufficient for a spurious trip of the load
Line Monitoring Pulses Compatibility
Line Monitoring Pulses are generated by DO cardstoverify the integrity of theLine and Load,ineitherEnergized orDe-EnergizedState.
GM International Relays are compatible to any LineMonitoredPulses and are designed to prevent:
· Contact chattering
·Spuriousload activation/deactivation ·Premature damage of theRelay unit.
Galvanic Isolators D6000 Series
GM International new universal mount Galvanic Isolators provide a simple and cost effective means of implementing isolation in non hazardous applications where SIL certificationand/orhighreliabilityarearequirement.
STRENGTHS
·SIL 2:TUVcertification;according IEC61508:2010,Ed.2 ·ReducedFootPrint:Highdensity:1,2,4or8ch.seach SimplifiedInstallation/Config.:DIPswitchconfigurability ·FasterReactionTime;LowerDownTime:LEDindication forpower,signalstatusandlinefault ·LowerOwnershipCost:Certifiedfor20yearsoperation ·ReducedSpareInventory:UniversalMounting(Stand AloneDIN-Rail,PowerBusSystemand TerminationBoards) ·Improved Reliability:Lowpower consumptionand heat dissipation ·HigherReliabilityIn&Outdoor:Certified-40°to+70°C ·RS-485Modbusoutputversionavailable
Structure
·High channeldensity(3/6/12mmper
channel)resulting from innovative
circuit design using advanced surface
mountcomponents
·Single,dual or quad channel models
·Plug-in screw terminal blocks to secure wiresupto 2.5\:mm2
· Configuration components are easily accessedbyremovingthesidecover orviaconnectorfrontpanel
Enhanced Galvanic Isolators
GMInternational SIL2certifiedIsolatorsaresuitablefor applicationsinallindustrial sectorsanddesignedtoachievethehighestpossiblereliabilityandavailabilitythrough the use of high temperature class components and low dissipation circuitry. Byavoidingtheuseofelectrolyticalcapacitors,andwithstate-of-the-artassemblyand testingfacilities,20yearsusefullifetimeisachieved.
LONGERLIFETIME
Capabilitytowithstand higher temperatures,improves the lifetime in normal conditions. ·Operating temperature
WIDEFUNCTIONALITY
certified from -40°\mathsf{C} to +70°C ·Very high reliability in extremeenvironment applications. · G3 conformal coating Reduced cabinet dimensions,requireless ventilation.
·Modules suitable for SIL 2 applications according to IEC61508,IEC61511
·Three port galvanic isolation to eliminate noise, groundloopproblems
·Line fault alarm detects open or short circuit of field cables
·OptionalpowerbusDIN-Rail connector
·StandardTerminationBoardwithcustom connectorsforintegrationintocustomizedBoards
·EMC Compatibility toEN61000-6-2,EN61000-6-4,
EN61326-1, EN61326-3-1for safety system
·DIP switch configurability for easy field setup
·LEDindicationforpower,signal status and linefault conditions
·Modules accept DC power supply overa wide rangefor24Vdc(18-30Vdc)applications
gmi
Universal Mounting units
The same device can be used in all applications to reduce spare inventory. ·DIN-rail stand-alone devices
.Standardandcustomizedterminationboards
·PowerbususingstandardTS35DIN-rail
Enhanced Power Bus Mounting
24 VdcPowerSupplyVoltagecanbe applied to the moduleby directly connecting to theplug-inTerminal Blockof eachmodule,orvia thePowerBusSystem.The system consistsofstandard DIN-Railmodulesmounted onDIN-Rail Busconnectors.The maximum allowed powering capacity per trunk is 8 A.It is always possible to remove modules,withoutdisconnecting thebus connectorwhichremainsattachedto theDINRail. Communication bus is provided,on suitable models,to transmit via Modbus toDCS PLClogicsolver.CumulativeFaultAlarmindicationisprovidedontheBusconnection. D5202Sredundant powersupply feed module providesSPST Relay contact for common andpowersupplyfaults;bothsupplyvoltages areindependently monitored. ·Redundant4Amppowersupplywithalarm
·Remotealarmindication
·Modulescanbecombinedforadditionalredundancy
SIL Certification
GM International D6000 series is designed and certified SIL 2 according to IEC 61508 ed.2and61511ed.2lateststandards.GMInternationalSystemCapabilitySC3allowthe useof ourisolatorsin1oo2or2oo3architectureforuptoSIL3 applications. SILdataisguaranteedforausefullifetimeof20yearsthankstoGMInternational's state-of-the-artsolutionsandmanufacturingexcellence.G3conformalcoatingand vibrationproof design guaranteeproblem freelong operation life instandard and harsh conditions:
·Highsignaltransferaccuracyandrepeatability ·Advanced circuitry provides very low heat dissipation,ensuring modules run cool
despitetheirhighdensityandfunctionality
·SMDmanufacturingforalong,reliablelife
· Complete absence of electrolytic capacitors ensures minimum 20 years lifetime
Configuration Tools & Software
SWc5o90softwareisdesignedtoprovideaPCuserinterfacetoconfigure suitableD6000,D6200modules,viaPPC5092adapter.
Itallowstheusertoeasily:
·Readandwriteconfigurationparameterstotheunit
·Storeandrestoredata toand fromlocalhard driveforbackupor archive
·Loadfactorydefaultconfigurations
·MonitorrealtimeInputvaluesfordebugortest
·Print a report sheet containing configuration parameters and additional information
SWC5090isfreelydistributedonourwebsite:www.gminternational.com PPC5092 interface allows the configuration ofD6000,D6200modulesviaSWC5090 software.
Modules are supplied via USB and therefore donot needexternalpowersupplywhile beingprogrammed.
PPC5092comeswithmini-USBcableand CD-RomcontainingSWC5090software.
Power Supplies PSx1200 Series
SIL 3 certified, 24 Vdc modular power supply suitable for installation in safe area and Zone/Division 2. Designed for 100% Availability and High Integrity applications; built-in load sharing in bothDIN rail and Rackmounted solutions
STRENGTHS
SmallerFootPrint:Verycompact design
·Flexibility:Wal/Rack/DinRail Types
·Environmentalcondition:Extendedtemperaturerange (-40°C ÷+70°C), G3 Coating,tested for Marine application (EMC, Vibration, etc.)
Zone2installation:ReducedCableDistance
·ImprovedSafety,IntegrityandReliability:SIL3certifiedby Third Party
·High efficiency-ReducedBulkPower&Dissipation:Builtin intelligent load sharing
·Easier Installation: No external OR-ing diodes needed for redundancy
·ZeroDowntime:Built-in Redundancy,operationunder outputshort-circuit condition,Automaticloadsharingof2 ormoremodules
·ReducedMaintenance Cost:Hot swapping,also inZone 2 (PSS1250)
GuaranteedFaultIsolation:ShortCircuitProtection
EasierTroubleshooting:LocalandRemote(Optional Modbus) diagnostic
Reasons for SIL 3 Power Supply
Duringnormaloperation,outputvoltageisconsideredsafebetween20and30Vdcand safestateistypicallywhentheoutputvoltageisOVdc;or closetoit.
However,allpowersuppliescanfail inconditionsdifferent fromzero;leadingto a dangerous state that can damage or put the load in an unstable/unsafe condition:Fail Hiah(above 30Vdc) orFail Low(Between2 Vdc and 20 Vdc).
Accordingtothe‘normativesection'of theIEC61508:2010part2-AnnexA-tableA.9, theglobalobjectiveistodetectortoleratebothunder-voltageand/orover-voltageand maintain your safety instrumented functions(SiF) in the normal operating range. Bothfailures can potentially lead to a hazardous situation, either damaging the instruments by overvoltage or not providing the necessary voltage for normal functioning oftheinstrument/device.
The majority of the SIF are working on the de-energise to trip principle where the main concernis availability of thepower and is solved withredundancy.However,redundancy isnotthesolutionforHiahorLowVoltaqefailures.
Special notice should be given to Energized toTripSIF where anyfailure of the power supplywillputsafetyatrisk.
GM International power supplies are designed and certified to guarantee an output voltageof 20-30Vdcunder normal and fault conditions.
Safety Function
·Keep the output power within the saferangefrom
20Vdc to 30Vdc. ·Prevent abnormal and dangerous conditions like: ·2Vdc < Output Voltage < 20Vdc ·Output Voltage > 30Vdc
Reasons for ldeal OR-ing Diode
High availabilitysystemsemploypowersupplymodulesconnected inparallelto achieve redundancyandenhancesystemreliability;typicallyusingaOR-ingDiode. OR-ing diodes introduce a significant voltage drop and will not equalize the load (load sharing). Becauseof thehighdissipated heat,theyareoftenthecauseoffailure. GM International Power Supply systemmakes use of Ideal Diode technology and Load Sharingcircuitry.
| ParallelingDiodes | SchottkyDiode | ActiveIdealDiode(AID) |
| Equivalentresistance | 16mQ | 1.2 mQ |
| Voltagedropat50A | 0.8V | 0.06V |
| Powerdissipationat50A | 40W | 3W |
| Efficiencyat1200w | 96.77% | 99.75% |
| Heat sink | Large | None |
| Voltageswitchovers | Withoscillations | Smooth,nooscillations |
PSD1220-098versionwithremovable terminals,whichareequivalent to predecessor
20 A, 24 V SIL 3 Power Supply
PSD1220 is the latest addition to the GM Internationalpower supply line,offering an innovative20AmpsDINRailunit.
It supersedes predecessor model PSD1210 doubling the output capacity,yet retaining the exactsamedimensions,terminalblocks andmounting arrangements.
Compactinsize,yetfullyfeatured:fromSIL3certificationtoautomaticloadsharing,high efficiencyandsuitableforinstallationinclassifiedareas.
·Nominal Input:110 / 240Vac ±10% (48/62\vdash1z)
·AdjustableOutput: 24/26 Vdc
.CurrentOutput:24Vdc/20 \mathsf{A}=480\mathsf{W}
·Efficiency (full loadl) >=93%@230\lor\mathsf{a c},>=91%@115\lor\mathsf{a c}
·Under/OverVoltagealarmoutput
·Upto10moduleswithparalleledoutputs
·Built-inOverLoadprotection andShort Circuitproof
·Extended temperaturerange (-40°\mathsf{C}/+60°\mathsf{C})
·SIL3Certification
·ATEX/IECEx:Zone2Installation
· G3 Conformal Coating
PSW1250 Structure
50 A, 24 V SIL 3 Power Supply · Wall or DIN-Rail mounting compact housing Load sharing up to 10 modules ·Remote alarm contact :Redundant fans
PSW1250 is the most powerful unit GM International can offer in a single Wall or Din Rail mountedsolution.
Innovativedesignandstate-of-the-artcircuitryhavebeenused toprovide50AMPSin sucha smallpackage;with efficiency higher than 89%
All the features of the rack mounted series are made available in this compact solution withSIL3certificationand installationin + 70°C ambienttemperature.
SPECIFICATIONS
·Nominal Input:110 /240 Vac ±10% (48/62\vdash1z)
·Adjustable Output: 21/28 Vdc
·CurrentOutput:24Vdc/50 \mathsf{A}=1.200\mathsf{W}
· Up to 10 modules with paralleled outputs
·Built-in Over Load protection and Short Circuit proof
·SIL3 Certification
·Redundant Fan with speed control: speed driven by temperature and output power
·ATEX/IECEx:Zone2 Installation
· G3 Conformal Coating
· Wall or rack mounting compact housing
Field configurable copper bar outputs
·DNV Marine Type approval
·2/4/6 modules configuration available
· Redundant AC supply connection
Short Circuit Proof & Diagnostics
Short circuit proof
In case of external short circuit,Pss1250system delivers avery high peak current(800 A)foradurationof 0.5~\mathsf{m s} toguaranteetheinstantopeningoftheprotectivefuseor circuitbreakerto avoidpowershut-down.
Other equipment connected to the load are not affected by the failure event and continue tooperatewithout interruption.
LocalandRemoteDiagnostics
PSO1250OverviewmodulewithLCDcolortouchscreendisplaywithModbusRTU communication.
MONITOREDPARAMETERS
·AC line voltage,current,power and frequency
·DC output voltage, current, power
·Current sharing % ofeachPSM1250
·Current sharing groupidentityforeach PSM1250
.PSM1250internaltemperature
·Fault conditionsofeachPSM1250:under -or over-voltage,AC off,PFC/PWM stage off,high temperature,fans malfunctioning
·Fault logging with date and time
Hot Swapping Feature
Hot swapping solution;also certified forZone2installation
·Power supply is close to the load,in Hazardous Area
·Lesscables,lowervoltagedrop,lowercosts
· Connection and Disconnection under power without interrupting operations (Certified)
Technical Specifications
PSS1250-19"RACK
PSS1250-9"RACK
PSS1250-7"RACK
·Nominal Input: 110 / 240Vac ±10% (48/62\vdash1z)
·Adjustable Output: 21/28 Vdc
·Max peak:300 Amps at 24Vdc
·Nominally 200Amps per Rack
·24 Vdc/300 A = 7200W(3600W x2
·Under/Over Voltage alarm output
·Built-in Over Load protection and Short Circuit proof
·RS485Diagnostic:PSO1250 Module
·SIL3 Certification
·RedundantFanwithspeed control
·ATEX/IECEx:Zone2Installation
·G3 Conformal Coating
· Nominal Input:110 / 240 Vac ±10% (48/62\dashv1z)
·AdjustableOutput: 21/28 Vdc·
Max peak:100Ampsat 24Vdc·
Nominally50Ampsper Rack·24
Vdc/100 \mathsf{A}=2^{*}400\mathsf{W} (1'200W x2)·
Under/Over Voltage alarm output ·
Built-in Over Load protection and ShortCircuitproof
·RS485Diagnostic:PSO1250 Module
·SIL3 Certification
·RedundantFanwith speed control
·ATEX/IECEx:Zone 2Installation
·G3 Conformal Coating
·Nominal Input: 110 / 240Vac ±10% (48/62\dashv1z)
·Adjustable Output: 21/28 Vdc
·Max peak:100Amps at 24Vdc
·Nominally 50 Amps per Rack
·24Vdc/100 \mathsf{A}=2^{*}400\mathsf{W} (1200W x2
·Under/OverVoltage alarm output
·Built-in Over Load protection and Short Circuit proof
·SIL3 Certification
·RedundantFan with speed control
·ATEX/IECEx:Zone2Installation
· G3 Conformal Coating
PSS1250 Configuration Examples
PSS1250-HS-7-3-D
TwoACsupplies,threeredundant50AOutputs,PSO1250overviewmodule.
Threegroupsoftwoparalleledmoduleseach.
PSS1250-HS-7-2-D
TwoACsupplies,oneredundant {100} \mathsf{A}+{} oneredundant50AOutputs,PSO1250overviewmodule.
One groupof four paralleled modulesandone group of twoparalleled modules.
Other Power Supplies Types
PSD5201
SIL 3 Intrinsically Safe Power Supply ·Supply24Vdc ·1Output 14.5 V -150 mA ·Output toZone 0/ Div.1 ·Zone 2/Div.2 installation
PSD1000
Universal InputPowerSupplyforD10o0SeriesIsolators
·Supply90-265Vac
·Output24Vdc,500mA
·2Unitscanbeparalleledforredundancyoradditionalpower
·RemoteindicationforPowerFailureforPSD10ooF
·Simplified installation using standard DIN Rail and plug-in terminal blocks adjacent to
D1000 Series Modules,without 50\;mm safety distance ·Zone 2/Div.2 installation
PSD1001
SIL 2/ SIL 3 Intrinsically Safe Power Supply
·Supply24Vdc
·4Independent,parallelableOutputs15V,20mA
·Output toZoneO/Div.1
·Output short circuit proof and current limited
·High Reliability, SMD components
·High Density,four channels per unit
·Simplified installation using standard DIN Rail and plug-in terminal blocks
·Zone 2/Div.2 installation
PSD1001C
SIL 2/ SIL 3 Intrinsically Safe Power Supply
·Supply24Vdc
·Output13.5V-100mA
·Output toZone 0/ Div.1
·Outputshortcircuitproofand currentlimited
·High Reliability,SMD components
·Simplified installation using standard DIN Rail and plug-in terminal blocks
·Zone 2/Div.2 installation
Multiplexer Systems D2000 Series
D20oo Temperature Multiplexer has been designed specifically for temperature measurements in Hazardous Location; taking full advantage of the low power requirementsinherentoftemperaturemeasurement.Fieldunitsdonotrequireseparate powersupplynorcertifiedenclosure.
STRENGTHS
ReducedFootPrint:HighDensity:upto256Channel
Longerdistances:upto5Km
·HigherReliability:Certified-40°to+60°C
·AvoidFault Propagation:Channel to channel isolation
ResiliencetoSurges:5ooVIsolation
·ImprovedMeasuringprecision:18Bitsaccurancy
FasterReactiontime:from0,4secfor64Ch.to1.6secfor 256Ch.
FasterDataCollection:112KBaud CommunicationSpeed
·ReducedBulkPowerSupply:Separatepowersupply not required
Harsh environment resistance: G3 conformal coating EasierTroubleshooting:Statusledindication
Structure
Multiplexer Advantages
Whena consistent numberof variablesistobecollectedfromaremotelocation,a simplersolutionistomultiplexthesignalsusingmasterandslaveunitstransferring multiplevariablesontothesametwowires;thissolutioneliminatestheneedforindividual wiring,transmitters,ISbarriersand analogInputchannels.
The data is then sent through a single,orredundant, communication line to the gateway placed insafearea.
Cable cost saving alone justifies the solution; additional savings are achieved given that 4{*}20\;\mathsf{m A} loop instrumentation is nolonger required.
The result is reduced and simplified wiring, lesser cabinet space and clutter free installation.
·Drastically reduces field wiring & installation costs
·Field units can be placed up to 5\;{\mathsf{k m}} fromGateway
·Eliminates theneedof PLC-DCSAl cards
·InstallationinZone1without theneedofexternalpowersourceorcertifiedenclosures ·Up to 256 signals per system; Maximum 7.936 ch.
·18 Bits Resolution and fast communication speed
·Easy,Robust&FieldProvenReliability ·Redundant communication lines to hazardous area (proprietary protocol) ·Redundant communication toPLC/DCS/PCvia Modbus RTU
D2050M Gateway/Power Supply Multiplexer Unit
D2030M Switch/Proximity Multiplexer Unit
System Architecture
D20oo Multiplexer acceptsboth analog and digital inputs in the samesystem allowing foravarietyofpotentialconfigurationstofitanyapplication.
Configurations with only Digital signals or onlyAnalog signal or combination of both are possibletosuit thebestsolutionintermsofcost andcabling.
Followingarejustsomeexamplesofsystemarchitecture.
Multiplexer: The Only Solution
Whenrevamping orexpansionsintheplant arerequired,thespacefor adding cables may be limited or the existing spare cablesmay be the only ones that can be used. Wireless solutionshave several limitations,highimplementation costs,and susceptible to cybersecurityrisk.
Multiplexing often becomes the only practical solution.
Pre-assembled,fullywired and customengineered field enclosures are available in severalconfigurations,sizeandmaterials.
Special, custom designed,FISCO cable(CABFOO8) for connection between field units andgatewayisalsoavailable.
Hazardous Area Multiplexing
For applications in classified Hazardous Areas,each signal must be protected from the risk of causing ignition of the present flammable mixtures:this requires a safety barrier for eachinputchannel.
ByusinganIntrinsicallySafemultiplexersolution, \mathsf{E X} protectionmustbeappliedonlyto the communication lines, decreasing complexity,maintenance and costs.
Software Configuration
SWC2090 Software Configurator
It easily allows the user to:
Configure and monitor the entire system with your PC/ Laptop via RS23
RS485connections ·Guideduserinterface ·Print completereport sheets ·Save configurations to file for backup ·Multilanguage
Surge Arresters D9000 Series
D90oo series provides surge protection for all kinds of applications in different industries such as Oil&Gas, Petrochemical, Steel etc. avoiding signal interruption and protectingcontrolroomequipment.
STRENGTHS
Easymaintenance:Integratedknifedisconnection technologyforeachchannel
·Quickwiring: Grounding path via contact toDIN rail
·Reduced spare inventory: Surge protection for most I/0 signals;Al,AO,DI,DO.Nominal 24V DC,maximum 36V (Both I.S. And N.l.S.)
IncreasestheDischargecapacityandreducesthe response time:2-stageprotective circuit(Diode,GasDischarge Tube)
·Unlimited IS applications: Input from Zone 0 (Zone 20), installation in Zone 1 and 2
· Fits in any SIL loop: SIL3 Certification
ProtectionLevel:upto20KA
·Local &remoteFastermaintenancereaction time: VersionsavailablewithFaultIndication
·Simpletesting and documentation,reduced downtime: AvailablewithHotSwapPlugmodule Safedisconnectionandsignalingincaseofoverload
D9024S Structure
a.Screwdriveroperableswitchonlinebetween terminals2and4.
b.Screwdriveroperableswitch on linebetween terminals1and3.
Universal Din Rail Surge Arrester
D9024S modules provide two-stage, SIL 3, surge protection for floating I/O signals for measurementincontrolandsafetysystems.
Its slim width of only 6mm allows for easy fitting into any marshalling or distribution cabinetsavingspaceandinstallationcosts.
Disconnect knife on both signal paths arefeatured for easy testing of the loop.
FEATURES
·SIL3accordingtoIEC61508:2010Ed.2
·Input from Zone O (Zone 20), installation in Zone 1 and2
·Disconnection of signal circuit by disconnect knife
·Protection of a floating double wire in intrinsically safecircuits
·HighDensity, 6.2\;mm perchannel
·HARTcompatible
Cartridge & Fault Indication Surge Arrester
D9400/D9500providessurge protection for floating I/Osignal circuit inaSIL3 compact packagewithorwithoutremovablecartridgeconfiguration.Thepluggablemoduleand disconnectknifeenable easy testing.
Alsofeaturedlocalandremotemodulefaultindications.
Intheeventofanoverload,astatusindicatoridentifiesthedisconnectionofthe
protective element without the need of auxiliarypower supply;a remoteindicationset,for upto 40modules ata time,is also available.
IntrinsicallysafecertifiedforuseinISloopsandforhazardous areainstallation.
FEATURES
·SIL3accordingtoIEC61508:2010Ed.2
·Localand RemoteFaultIndication
·Disconnection of signal circuit by disconnect knife
·Hot Removable plug module version available (D9500 version)
·EX-i Certified
·High Density 6.2\;\mathsf{mm} per channel
·Protection of a floating double wire in intrinsically circuits
·HART Compatible
D9324S Structure
Screw-on S.S. Surge Arrester
D9324S provides surge protectionforfloating I/O signalcircuit ina screw-on module Ex-d certified andwithIP67protectionforsensor heads;connection 1/4"NPT. Suitableforinstallationontoexplosionproofenclosuresforawiderangeof applications.
FEATURES
·SIL3according toIEC61508:2010Ed.2
·Input from Zone 0 (Zone 20),installation in Zone 1 and2
·Protection of a floating double wire in intrinsically safecircuits
.Suitableforexplosionproofenclosures
·HARTcompatible
HART Multiplexer System
ThenewSIL3certifiedGMInternational HARTInterfaceSystemdrasticallyreduces thecomplexityandcostofHMSinstallations;comparedtothecurrentstate-of-theartHARTinterfacesolutionsonthemarket,GMIHARTSystemsignificantlycutsthe numberofmultiplexermodulesrequiredandincreasesthespeedofcommunication to115.200bps
STRENGTHS
Reducedfootprint:HighDensity:256Channel ·IncreasedArchitectureAbility:63configurableaddresses Fasterdataacquisition:115.200BaudSpeed Reduced wiring: Slaves are not required·Higher Reliability In&Outdoor:Certified-40°to+70°C·Higher resiliance:Channeltochannel isolation·DataGuaranteed by3rdParty:SIL3TUVcertification·Current&Valid Standard:CertifiedIEC61508:2010,Ed.2·Lower OwnershipCost:Certified for20yearsoperation
Structure
GMI HART MuX Solution
ByeliminatingtheneedtouseslavestheGMInternationalHartMultiplexersolution offers aninnovativeand low-costsolutionforHARTMaintenanceStationprojects. Each5700 HART Mux supports up to256HARTsignals with sufficient communication speed thankstoabaudrateincreasedto115.200bps.
COMMUNICATION PROTOCOL
FEATURES
·Reduced Number of components ·Reduced Wirings and Complexity ·Reduced Spare Parts Inventory ·Increased performances
·Multidrop up to 16.128 channels ·SIL3certification
·Hart7compatible
PLANTMANAGEMENTSW
FDT Container compatible with Hart MaintenanceSoftware ·Pactware 4.1,5.0 and above
(PACTwareConsortium) ·FDT Container (M&M) ·E+H Fieldcare (Endress ^+ Hauser) ·Field Mate (Yokogawa) ·PRM (Yokogawa) ·FDM (Honeywell) ·ValveLink (Emerson)
Termination Boards Standard and customized
Termination boards provide direct connection via dedicated multicore cable between the I/O Card of the system (PLC/DCS/ESD) and electronic modules (barriers, isolators, relays). GM International offers a widerange of standard or customized termination boards to easily interface to systems of all the main instrumentation vendors such as: Invensys Foxboro, ABB, Triconex, Yokogawa, Honeywell and many others. GM International terminationboardsarealsoavailablewiththenewHARTInterfaceSystem thatdrasticallyreducesthenumberofmultiplexermodules
STRENGTHS
SmallerFoot Print:Very compact design,up to64 1/O ChannelsinoneBoard
Flexibility:MountinghardwareforDINRailorWall
High Availability:Power Supply and support of I/O Redundancy
EasymaintenanceandTroubleshooting:FaultLed Indicationandcommonfaultrepeater
Availablewithcustomizedconnectors/cablesfordirect interfacetoanyPLC/DCS/ESDSystems
·AlsoavailablewithGMIHARTInterfaceSystemthat drasticallyreducesthenumberofmultiplexermodules.
Al/AO/DI/DoUniversal:anyD5000orD6000series
modules can be installed:IS Barriers,Isolators,Safety
Relays
Typical structure
Universal Termination Boards
GMITerminationBoardsare suitableforinstallationofanyAl/Ao/DI/DOmodulesof the D5000/D6000 and D1000 series: IS Barriers, Isolators and Safety Relay.
Universal solutions are available using patch cables or can be customized to suit the growingnumberofUniversal I/omodules.
All Analog TBs support connection to GMl innovative HART Multiplexersolution via flat orflat-to-roundcable.
FEATURES
·Redundant power supply connection
· Line voltage monitoring and alarm
.Suitable tohost 8/16/32Modules
·Up to 64 Channels per TB
·Universal: AI/AO -DI/DO -TEMP./ CONVERTER
·Dedicated HARTSignals connector
·Wall or DIN Rail Mounting
·G3 conformal coating and Zone 2 Installation
BENEFITS
·Simplified wiring and maintenance
·Reduces cabinet and installation costs
·Small overallFoot print
·System dedicated and compatible plug-in solution
·Easy spare/extensions management
Field IndicatorsT3000 Series
T3010s offers simple and effective process variable read-out in Hazardous Locations. Loop powered, 4-20 mA unit with less than 1V voltage drop designed to display the processvariables inanyengineeringunitsbetween-19999to+19999. Clear 20mm height, 7-segments LCD display blinking to indicate over or under-range conditions.
Aprotectedslottoinsertthemeasuredengineeringunit label isprovided,afterthelast digit,foreasyidentification.Looptagindicationcanbealsoprovided. Theindicatorishoused inacompactIP66enclosureforinstallationinthefieldandcan bemountedonflatsurface,frontpanelor2"pipeorpost.
STRENGTHS
HigherVisibility:LargeLCDDisplay,20mmhigh Increased applicability:Lowvoltage drop(<1V) EasierMaintenance:IP66Enclosurewith2chambers · Wall, Pipe-Post, or Panel mounting SimplifiedInstallation:Fieldconfigurable ·ImprovedReliability:UnderandOverrangedetection Easieridentification:Protectedslotavailablefor engineeringvaluelabel HazardousandSafeAreaVersionsAvailable
Structure
4 12 Digit Loop Powered Indicator
T3010sunitscanbeconnected inseriestoa 4{*}20\;\mathsf{m A} loop(figureA)orcan be drivenfromSafeArea toprovidelocal indication inHazardousAreasup to Zone0/Div.1(figureB).
In both cases,the unit must beprotected by a suitable intrinsically safe barrier.
Pleasecheckdatasheetforfurtherinformation.
Figure A
gmi
Product List
I.S. Barriers
| Models | N.Ch. | L.M. | Input | Output | Duplicator | Alarm | SIL | Size | Note | ||
| Active | Passive | Source | Sink | ||||||||
| D5011 | 1/2 | 3 | 12.5 mm | HART | |||||||
| D5014 | 1/2 | 3 | 12.5 mm | HART | |||||||
| D5015 | 1/2 | 2 | 12.5 mm | HART | |||||||
| D5212Q | 4 | 2 | 22.5mm | Modbus | |||||||
| D5254S | 1 | 2 | 22.5mm | Modbus | |||||||
| D5072 | 1/2 | TC, mV,RTD,Q, Pot | 2 | 12,5 5mm | Modbus | ||||||
| D5072S-087 | 1 | 2-3-4wire RTD | 2-3-4wire RTD | 2 | 12,5 mm | RTDtoRTD | |||||
| D5072-096 | 1/2 | TC, mV | mV | 2 | 12,5 mm | mV to mV | |||||
| D5273S | 1 | TC,mV,RTD,,Pot | 2 | 22,5mm | Modbus | ||||||
| Models | N.Ch. | L.M. | Input | Output | Duplicator | Alarm | SIL | Size | Note |
| D5020 | 1/2 | 4-20 mA | 4-20 mA | 2 | 12.5 mm | HART |
| Models | N.Ch. | L.M. | Input | Output | Duplicator | Alarm | SIL | Size | Note |
| D5030 | 1/2 | Drycontact/Namur | Relay | 3 | 12.5 mm | ||||
| D5031 | 1/2 | Dry contact/Namur | Voltagefreecontact | 3 | 12,5 mm | ||||
| D5032 | 1/2 | Drycontact/Namur | Relay | 3 | 12,5 mm | OnlyforTB | |||
| D5034 | 1/2 | Namur | Namur | 3 | 12,5 mm | Transparentfor Namur | |||
| D5036 | 1/2 | Drycontact/Namur | Relay | 2 | 12.5 mm | NoG3Coating | |||
| D5037 | 1/2 | Dry contact/Namur | Voltagefreecontact | 2 | 12,5 mm | NoG3Coating | |||
| D5231E | 8 | Drycontact/Namur | SolidStateRelay | 2 | 22,5 mm | Logical outfunc.+Modbus |
| Models | N.Ch. | L.M. | Input | Output | Powersupply | Alarm | SIL | Size | Note |
| D5040 | 1/2 | 24Vdc | Solenoidvalve/ LED | Looppowered | 3 | 12,5 mm | 2..4FieldSelectableOut | ||
| D5048S | 1 | 24Vdc | Solenoidvalve/LED | Looppowered | 3 | 12,5 mm | 1.3FieldSelectableOut | ||
| D5049S | 1 | 24Vdc/Drycontact | Solenoidvalve/LED | Buspowered | 3 | 12,5 mm | 1.3FieldSelectableOut | ||
| D5240T | 3 | 24Vdc/Drycontact | Solenoidvalve/LED | Buspowered | 2 | 22,5 mm | 3..9FieldSelectableOut | ||
| D5244 | 1/2 | 24Vdc | Relay | LoopPowered | 2 | 22.5mm | VoltageFreeRelayOut |
| Models | N.Ch. | L.M. | Input | Output | Powersupply | Alarm | SIL | Size | Note |
| D5062S | 1 | Vibrationsensor | 0 to-20v | Buspowered | 2 | 12.5 mm | |||
| D5093 | 1/2 | 24-220Vdc/Vac | Voltagefreecontact | LoopPowered | 3 | 12,5 mm | NIS Digital input module | ||
| D5263S | 1 | Strain gauges | Straingauges | Buspowered | 2 | 22,5 mm | |||
| D5264S | 1 | Strain gauges | 4-20 mA | Bus powered | 2 | 22,5 mm | Modbus | ||
| D5202S | 24V,4A | Buspowered | 3 | 22,5 mm | Powerfeedmodule |
| Models | N.Ch. | L.M. | Input | Output | Duplicator | Alarm | SIL | Size | Note | ||
| Active | Passive | Source | Sink | ||||||||
| D1010 | 1/2 | 2 | 22,5 mm | HART | |||||||
| D1014 | 1/2 | 2 | 22.5 mm | HART | |||||||
| D1012Q | 4 | 22.5 mm | |||||||||
| D1052 | 1/2 | 22,5 mm | Duplicator,High/Lowvoltage selector,adder/subtractor | ||||||||
| D1053S | 1 | 2 | 22,5 mm | ||||||||
| D1054S | 1 | 2 | 22.5mm | HART | |||||||
| D1072 | 1/2 | UniversalTemperature | 2 | 22,5 mm | VoltageOutput | ||||||
| D1073S | 1 | UniversalTemperature | 2 | 22,5 mm | VoltageOutput | ||||||
| Models | N.Ch. | L.M. | Input | ndno | Duplicator | Alarm | SIL | Size | Note |
| D1020 | 1/2 | 4-20 mA | 4-20mA | 2 | 22,5 mm | HART |
| Models | N.Ch. | L.M. | Input | do | Duplicator | Alarm | SIL | Size | Note |
| D1030 | 1/2 | Drycontact/Namur | Relay | 2 | 22,5 mm | ||||
| D1031 | 2 / 4 | Dry contact/Namur | Transistor | 2 | 22,5 mm | ||||
| D1032 | 2 / 4 | Dry contact/Namur | Relay | 2 | 22,5 mm | ||||
| D1033 | 2 / 4 | Drycontact/Namur | Transistor | 2 | 22,5 mm | ||||
| D1034 | 1/2 | Namur | Namur | 3 | 22,5 mm | Transparent for Namur | |||
| D1130 | 1/2 | Drycontact/Namur | Relay | 2 | 22.5 mm | ACSupply |
| Models | N.Ch. | L.M. | Input | Output | Powersupply | SIL | Size | Note |
| D1040Q | 4 | 24Vdc/Drycontact | Solenoidvalve/LED | Bus/Looppowered | 3 | 22,5 mm | 1..4FleldSelectableOutputs | |
| D1041Q | 4 | 24Vdc/Drycontact | LED | Bus/Looppowered | 3 | 22,5 mm | 1..4FieldSelectableOutputs | |
| D1042Q | 4 | 24Vdc/Drycontact | Solenoidvalve/LED | Bus/Looppowered | 3 | 22,5mm | 1..4FieldSelectableOutputs | |
| D1043Q | 4 | 24Vdc/Drycontact | Solenoidvalve/LED | Bus/Looppowered | 3 | 22,5mm | 1..4FieldSelectableOutputs | |
| D1044 | 1/2 | 24Vdc | Relay | Looppowered | 2 | 22,5mm | VoltageFreeRelayOutput | |
| D1045Y | 1 | 24Vdc/Drycontact | Solenoidvalve | Bus/Looppowered | 22.5 mm | forATOSvalve | ||
| D1046Y | 1 | 24Vdc/Drycontact | Solenoidvalve | Bus/Looppowered | 22,5mm | forWANDFLUHvalve | ||
| D1048S | 1 | 24Vdc | Solenoidvalve/LED | Looppowered | 3 | 22,5mm | 1.3FieldSelectableOut | |
| D1049S | 1 | 24Vdc/Drycontact | Solenoidvalve/LED | Bus powered | 3 | 22.5 mm | 1..3FieldSelectableOut |
| Models | N.Ch. | L.M. | Input | Output | Powersupply | Alarm | Size | Note |
| D1010S-054 | 1 | mV | 4-20 mA | Buspowered | 22.5mm | Fastresponsetime | ||
| D1022 | 1/2 | 0-40 mA | 0-40 mA | Looppowered | 22,5 mm | FGSdetector | ||
| D1035S | 1 | Frequency | Voltagefreecontact | Buspowered | 22,5 mm | |||
| D1060S | 1 | Frequency | Voltagefreecontact | Buspowered | 22.5mm | |||
| D1061S | 1 | RS422/RS485 | RS232/RS422/RS485 | Buspowered | 22.5 mm | Fleld Buscompatible | ||
| D1062S | 1 | Vibrationsensor | 0to-20V | Buspowered | 22.5 mm | |||
| D1063S | 1 | Strain gauges | Strain gauges | Buspowered | 22,5mm | |||
| D1064S | 1 | Straingauges | 4-20 mA | Buspowered | 22,5mm | Modbus | ||
| D1080D | 2 | 3wireSensor | Relay | Buspowered | 22,5mm | |||
| D1081D | 2 | 3wire Sensor | Voltagefreecontact | Buspowered | 22,5 mm | |||
| D1180D | 2 | 3wireSensor | Relay | Buspowered | 22,5mm | ACSupply |
Safety Relays
| Model | N.Ch. | Relay | Load | NO/NC | Coil/Input | Contact Rating | High Availability | Pulse test | Diagnostics | Note |
| S06050 | 1 | NE | NE | NO | 24Vdc | 5A | · | |||
| D5090S-086 | 1 | ND | NE | NC | 24Vdc | 5A | ||||
| 1 | ND | NE/ND | NO/NC | 24Vdc | 5A | |||||
| D5094S | 1 | NE/ND | NE/ND | NO | 24Vdc | 5A | . | |||
| D5095S | 1 | NE/ND | NE/ND | NC | 24Vdc | 5A | ||||
| D5096S | 1 | NE/ND | NE/ND | NO | 24Vdc | 5A | Full dlagnostics | |||
| D5097S | 1 | NE/ND | NE/ND | NC | 24Vdc | 5A | Full diagnostics | |||
| 86090 | 1/2 | NE | NE | NO | 24Vdc | 5A | ||||
| D5290S | 1 | NE | NE | NO | 24Vdc | 10A | ||||
| D5290S/SA | 1 | NE | NE | NO | 24Vdc | 5A | ||||
| D5290S-078 | 1 | NE/ND | NE/ND | NO/NC | 24Vdc | 5A | 1,2 or 4Loads | |||
| D5290S-078/SA | 1 | NE | NE/ND | NO/NC | 24Vdc | 5A | 1.2 or3 Loads | |||
| D5290S-079 | 1 | NE | NE/ND | NO/NC | 115Vac | 5A | 1.2or 4 Loads | |||
| D5290S-080 | 1 | NE | NE | NO | 115Vac | 10A | ||||
| D5290S-084 | 1 | NE | NE/ND | NO/NC | 110Vdc | 5A | 1. 2 or 4 Loads | |||
| D5290S-091 | 1 | NE | NE | NO | 230Vac | 10A | ||||
| D5290S-092 | 1 | NE | NE | NO | 48Vdc | 10A | ||||
| D5291S | 1 | ND | NE/ND | NO/NC | 24Vdc | 10 A | ||||
| D5292 | 1/2 | NE/ND | NE/ND | NO | 24Vdc | 5A | ||||
| D5292S-093 | 1 | NE/ND | NE/ND | NO/NC | 24Vdc | 5A | ||||
| D5293S | 1 | NE | NE | NO | 24Vdc | 5A | Modbus | |||
| D5294S | 1 | NE/ND | NE/ND | NO | 24Vdc | 5A | Programmable,Modbus | |||
| D5295S | 1 | NE/ND | NE/ND | NC | 24Vdc | 5A | · | Programmable,Modbus |
| Model | N.Ch. | Relay | NO/NC | Coil/lnput | Contact Rating | High Availability | Pulse | Diagnostics | Note | |
| D1092 | 1/2 | NE/ND | NE/ND | NO | 24Vdc | 3A | ||||
| D1092-069 | 1/2 | NE | NE/ND | NO/NC | 24Vdc | 3A | ||||
| D1093S | 1 | NE/ND | NE/ND | NO | 24Vdc | 3A | Opencircuitdlagnostics |
Galvanic Isolators
| Models | N.Ch. | L.M. | Input | Output | Duplicator | Alarm | SIL | Size | Note | ||
| Active | Passive | Source | Sink | ||||||||
| D6011 | 1/2 | 2 | 12,5 mm | HART | |||||||
| D6014 | 1/2 | 2 | 12,5 mm | HART | |||||||
| D6015 | 1/2 | 2 | 12,5 mm | HART | |||||||
| D6212Q | 4 | 2 | 22,5 mm | Modbus | |||||||
| D6254S | 1 | 2 | 22,5 mm | Modbus | |||||||
| D6072 | 1/2 | TC,mV,RTD,,Pot | 2 | 12,5 mm | Modbus | ||||||
| D6072S-087 | 1 | 2-3-4wireRTD | 2-3-4wire RTD | 2 | 12,5 mm | RTDtoRTD | |||||
| D6072-096 | 1/2 | TC,mV | mV | 2 | 12,5 mm | mV to mV | |||||
| D6273S | 1 | TC,mV.RTD,,Pot | 2 | 22.5mm | Modbus | ||||||
| Models | N.Ch. | L.M. | Input | Output | Duplicator | Alarm | SIL | Size | Note |
| D6020 | 1/2 | 4-20mA | 4-20 mA | 2 | 12.5 mm | HART |
| Models | N.Ch. | L.M. | Input | Output | Duplicator | Alarm | SIL | Size | Note |
| D6030 | 1/2 | Drycontact/Namur | Relay | 2 | 12,5 mm | ||||
| D6031 | 1/2 | Drycontact/Namur | Voltagefreecontact | 2 | 12,5 mm | ||||
| D6032 | 1/ 2 | Drycontact/Namur | Relay | 2 | 12,5 mm | OnlyforTB | |||
| D6034 | 1/2 | Namur | Namur | 2 | 12.5 mm | TransparentforNamur | |||
| D6036 | 1/ 2 | Drycontact/Namur | Relay | 2 | 12.5 mm | NoG3Coating | |||
| D6037 | 1/2 | Drycontact/Namur | Voltagefreecontact | 2 | 12,5 mm | NoG3Coating | |||
| D6231E | 8 | Dry contact/Namur | SolidStateRelay | 2 | 22,5 mm | Logical outfunc.+Modbus |
| Models | N.Ch. | L.M. | Input | Output | Powersupply | Alarm | SIL | Size | Note |
| D6263S | 1 | Strain gauges | Strain gauges | Buspowered | 2 | 22,5 mm | |||
| D6264S | 1 | Strain gauges | 4-20 mA | Buspowered | 2 | 22,5 mm | Modbus |
Surge Arresters
| Models | N.Ch. | N. Wires | SignalType | Removable cartridge | Fault Indication | Mounting | SIL | Size | Note |
| D9024S | 1 | 2 | 24VdC AI,AO,DI,DO | DIN-Rail | 3 | 6mm | |||
| D9410S | 1 | 2 | 24VdcAI,AO,DI,DO | DIN-Rail | 3 | 6 mm | |||
| D9420S | 1 | 3 | BusSystem | DIN-Rall | 3 | 6mm | |||
| D9510S | 1 | 2 | 24Vdc AI,AO,DI,DO | DIN-Rall | 3 | 6mm | |||
| D9520S | 1 | 3 | Bus System | DIN-Rail | 3 | 6mm | |||
| D9401S | 1 | DIN-Rail | 3 | 6 mm | RemoteFaultindicatorSet | ||||
| D9324S | 1 | 2/3 | 24VdcAI.AO.D1.DO | 1/2"NPT | 3 | 24 mm |
Multiplexer Systems
| Models | N.Ch. | Input | Function | LineMonitoring | Installation Area | Size | Note |
| D2010M | 16 | Analog-temperature | Fleldmultiplexer | Hazardous | 220mm | Ch.toCh.isolation | |
| D2011M | 16 | Analog-temperature | Extendermodule | Hazardous | 220 mm | Ch.toCh.isolation | |
| D2030M | 32 | Digital -Namur | Field Multiplexer | Hazardous | 220mm | Ch.to Ch.isolation | |
| D2050M | 256 | SignalsfromField Units | Gateway | Safe | 220 mm | Redundantcommunication | |
| D2052M | 32 | DISignalsfromD205oM | Repeater | Safe | 220 mm | RelayOutput | |
| D2053M | 32 | DISignalsfromD2050M | Repeater | Safe | 220 mm | VoltagefreecontactOutput | |
| D1090Q | 4 | mA / A | ShuntModule | Hazardous | 22,5 mm | Current Input Shunt | |
| D1094Q | 4 | V | DividerModule | Hazardous | 22,5 mm | VoltageInputDivider |
Power Supplies
| Models | Output | Mounting | Fault Indication | SIL | Installation Area | Size | Note |
| PSD1000 | 24Vdc-0.6A | DIN-Rall | Safe orZone2 | 22.5mm | |||
| PSD1000F | 24Vdc-0.6A | DIN-Rall | Safe orZone2 | 22.5 mm | |||
| PSD1001 | 15Vdc-20mA | DIN-Rail | 3 | Safe orZone2 | 22,5 mm | I.S.Device | |
| PSD1001C | 13,5Vdc-100mA | DIN-Rail | 3 | Safe orZone2 | 22,5 mm | I.S.Device | |
| PSD5201 | 14.5Vdc-150mA | DIN-Rail | 3 | Safe orZone2 | 22,5 mm | I.S.Device | |
| PSD1220 | 24Vdc-20A | DIN-Rail | 3 | Safe orZone2 | 183 mm | ||
| PSD1220-098 | 24Vdc-20A | DIN-Rail | 3 | Safe orZone2 | 183 mm | ReplacementofPSD1210 | |
| PSW1250 | 24Vdc-50A | Wall-Mount | 3 | Safe orZone2 | 61mm | ||
| PSM1250 | 24Vdc-50A | Wall-Mount | 3 | Safe orZone2 | 61mm | ||
| PSO1250 | Wall-Mount | Safe orZone2 | 61mm | Dlagnostics module | |||
| PSS1250-HS | 24V-300A 48V-150A | Wall-Mount | 3 | Safe orZone2 | 178/238/482mm | Hot Swap, Varioussizeavailable | |
| PSS1250 | 24V-300A 48V-150A | Wall-Mount | 3 | SafeorZone2 | 178/238/482mm | Varioussizeavallable |
HART Multiplexer
| Models | N.Ch | SignalType | Function | SIL | Size | Note |
| 5700 | 256 | HARTSignals | MasterandSlavemodule | 3 | 12,5 mm | From1to256Channels |
| TB-D5001 HRT-003 | 64 | HARTSignals | FlatcableTB | 176 mm | ForconnectionviaGMITB | |
| TB-D5001- HRT-O04 | 32 | HARTSignals | Hard terminalsTB | 218 mm | FordirectconnectiontoHARTsignal |
Field Indicators
| Models | N.Ch. | Input | PowerSupply | IPRating | Installation Area | Size | Note |
| T3010S | 4,5 | 4-20mA | LoopPowered | 65 | Hazardous | 144 mm | Mounting Kit available |
| T3010S-NIS | 4,5 | 4-20mA | LoopPowered | 65 | Safe | 144 mm | Mounting Kit available |
Termination Boards
| Models | N.Ch. | N.of Modules | Signal Type | System | CardDetail | Size | Note |
| TB-D5008-GMI-001 | 8/16 | 8 | Universal | patchcables | any | 156 mm | HARTconnector |
| TB-D5008-GMI-002 | 8/16 | 8 | AO | patchcables | any | 166 mm | HARTconnector |
| TB-D5016-GMI-001 | 16 /32 | 16 | Universal | patchcables | any | 300mm | HARTconnector |
| TB-D5208-GMI-001 | 8/16 | 8 | Universal | patchcables | any | 230mm | HARTconnector |
CUSTOMBOARDS
CustomizedTerminationBoardsforan easyintegrationwithinstrumentationofmanufacturers areavailable:
ABB Foxboro ICS Triplex Siemens Bailey Hima Invensys Triconex Emerson Honeywell Schneider Yokogawa
NOTE
CustomTerminationBoardsareinconstantdevelopment.Please enquireifanydesired terminationboardismissing.