HISTORY
2017-2019
2006-2017
2006: IKNOW ACTUATOR Co., Ltd. was established.
2013: IKNOW independently developed "ZH series linear
stroke pneumatic actuators" and achieved mass production.
IKNOW obtained multiple "utility model patent certificates".
2017: "ISO 9001 Quality System Certification"
"SIL 3 Safety Integrity Level Certificate"
"Science and technology SMEs in Zhejiang Province".
2018: IKNOW independently developed the "rod-type scotch yoke pneumatic actuator" and achieved mass production. "High-growth technology-based SMEs in Zhejiang Province".
2019: IKNOW independently developed "rodless scotch yoke pneumatic actuator" and achieved mass production. "IKNOW" trademark successfully registered in the US and UK.
2021-2023
2021: IKNOW obtained two "invention patents".
2022: IKNOW obtained "TUV SIL 3 Functional Safety Certification" for its full range of pneumatic actuator products.
2023: "National High-Tech Enterprise" "National-level technology-based SMEs" "Special production equipment license".
2024-2025
2024: "Specialized, Refined, Characteristic, and Innovative SMEs in Zhejiang Province" "TS Type Test Certification."; "IS09001 Quality System Certification" "ISO45001 OccupationalHealth and Safety Certification" "ISO14001 Environmental Management System Certification" "CE", "ATEX ", " EAC".
2025: company has obtained the "CU-TR(EAC) Eurasian Certification "for its full range of pneumatic actuator products."ATEX EU Explosion-proof Certification ". "CE", "ATEX", "EAC".
IKNOW Trademark successfully registered in Russia.
Adhering to the philosophy of continuous innovation
IKNOW consistently sticks to concept of "innovative manufacturing, actuating the future" throughout decade of development.Getting deeper into clients' actual working conditions and through continuous technical innovation,
IKNOW has independently developed and manufactured RT series rack and pinion pneumatic actuators, ING series scotch yoke pneumatic actuator, and ZH linear pneumatic actuator. IKNOW takes advantage of expertise to provide customized, comprehensive, and one-stop process control solutions for clients. Our company's product quality has been positively commented by end users in industries such as construction, biomedicine, fire protection, drainage, petrochemicals, metallurgy, paper-making, and power plant, etc.
Mission
Making every valve controlled all over the world;
making every valve controlled more precisely.
Vision
To build IKNOW into a leading world-renowned actuator brand
Values
Client-based, customized solutions
Innovation-driven, excellent actuation
CE Certificate
Qualification Certificates
浙江省专精特新中小企业
National High-tech Enterprise
Specialized, Refined, Distinctive and Innovative SMEs
EAC Certificate
EAC Certificate
EAC 012 Directive
< Test Equipment
< Ordering Information
| EX | RT | 020 | SR | K10 | NONE | RT Aluminum Alloy Series, Φ52Cylinder Size,Single Acting with10Springs, 90°Rolotion. | |||
| Series | RT | RTAluminum Alloy Series | |||||||
| Model | 007 | Φ32 Cylinder Size | |||||||
| 012 | Φ40 Cylinder Size | ||||||||
| 020 | Φ52 Cylinder Size | ||||||||
| 035 | Φ63 Cylinder Size | ||||||||
| 050 | Φ75 Cylinder Size | ||||||||
| 075 | Φ83 Cylinder Size | ||||||||
| 110 | Φ92 Cylinder Size | ||||||||
| 160 | Φ105 Cylinder Size | ||||||||
| 255 | Φ125 Cylinder Size | ||||||||
| 435 | Φ140 Cylinder Size | ||||||||
| 665 | Φ160 Cylinder Size | ||||||||
| 1000 | Φ190 Cylinder Size | ||||||||
| 1200 | Φ210 Cylinder Size | ||||||||
| 1800 | Φ240 Cylinder Size | ||||||||
| 2700 | Φ270 Cylinder Size | ||||||||
| 3800 | Φ300 Cylinder Size | ||||||||
| 5700 | Φ350 Cylinder Size | ||||||||
| 8000 | Φ400 Cylinder Size | ||||||||
| Acting Type | DA | - | Double Acting | ||||||
| SR | 1 | Spring Return | |||||||
| Spring Qty | NONE | - | No Spring | ||||||
| K5 | 1 | 5PCS | |||||||
| K6 | 1 | 6PCS | |||||||
| K7 | 1 | 7PCS | |||||||
| K8 | - | 8PCS | |||||||
| K9 | - | 9PCS | |||||||
| K10 | - | 10PCS | |||||||
| K11 | 1 | 11PCS | |||||||
| K12 | - | 12PCS | |||||||
| Travel | NONE | 90°Rolotion | |||||||
| 120 | 120°Rolotion | ||||||||
| 135 | 135°Rolotion | ||||||||
| 180 | 180°Rolotion | ||||||||
| Temperature | LT | -40°℃ to +80°℃ | |||||||
| LLT | -60°C to +80°℃ | ||||||||
< Product Architecture
Indicator
Position indicator with NAMUR is convenient for mounting accessories such as Limit Switch box,Positioner and so on.
Actuator Body
According to the different requirements, the extruded aluminum alloy ASTM6005 Body can be treated with hard anodized, powder polyester painted (different colours is available such as blue, orange, yellow etc.) PTFE or Nickel plated.
Pinion
The pinion is of high-precision integral type, made of nickel-alloy steel, fully complying with the latest ISO5211.DIN3337.NAMUR standards. Custom dimensions are available; stainless steel is optional.
End Caps
Die-casting aluminum powder polyester painted in different colours, PTFE or Nickel plated.
Pistons
The twin rack pistons are made from Die-casting aluminum treated with Hard anodized or made from Cast steel with galvanization. Symmetric mounting position,long cycle life and fast operation, reversing rotation by simply inverting the pistons.
Bearings&Guides
Made from low friction,long-life compound material,to avoid the direct contact between metals. The maintenance and replacement are easy and convenient.
Travel Adjustment
The two independent external travel stop adjustment bolts can adjust ± 5°at both open and close directions easily and precisely.
High Performance Springs
Preloaded coating springs are made from the high quality material for resistant to corrosion and longer service life, which can be demounted safely and conveniently to satisfy different requirements of torque by changing quantity of springs.
O-rings
NBR rubber O-rings provide trouble-free operation at standard temperature ranges.For high and low temperature applications Viton or Silicone.
Parts and Materials
| No. | Description | Qty. | Standards Material | Protection | Optional Meterial |
| 1 | Indicator screw | 1 | Plastic | ||
| 2 | Indicator | 1 | Plastic | ||
| 3 | Shaft retaining ring | 1 | Stainless Steel | ||
| 4 | Thrust washer | 1 | Stainless Steel | ||
| 5 | Outside washer | 1 | Engineering Plastics | ||
| 6 | Body | 1 | Extruded Aluminum Alloy | Hard Anodized Etc | Stainless Steel |
| 7 | Inside washer | 1 | Engineering Plastics | ||
| 8 | Cam | 1 | Alloy Steel | ||
| 9 | Upper shaft bearing | 1 | Engineering Plastics | ||
| 10 | Upper shaft O-ring | 1 | NBR | Viton/Silicone | |
| 11 | Gear shaft | 1 | Alloy Steel | Nickel Plated | Stainless Steel |
| 12 | Lower shaft bearing | 1 | Engineering Plastics | ||
| 13 | Lower shaft O-ring | 1 | NBR | Viton/Silicone | |
| 14 | Plug | 2 | NBR | Viton/Silicone | |
| 15 | O-ring (Adjust Screw) | 2 | NBR | Viton/Silicone | |
| 16 | Adjustment Nut | 2 | Stainless Steel | ||
| 17 | Adjustment bolt | 2 | Stainless Steel | ||
| 18 | Piston | 2 | Cast Aluminum /Casting | Anodized/Zinc Galvanized | Stainless Steel |
| 19 | Piston guide plate | 2 | Engineering Plastics | ||
| 20 | Piston bearing | 2 | Engineering Plastics | ||
| 21 | Piston O-ring | 2 | NBR | Viton/Silicone | |
| 22 | Spring | 0~12 | Spring Steel | Dip Coating | |
| 23 | End cap O-ring | 2 | NBR | Viton/Silicone | |
| 24 | End Cap | 2 | Cast Aluminum | Powder Polyster Painted Etc | |
| 25 | End cap bolts | 8 | Stainless Steel | ||
| 26 | Stop Screw | 2 | Stainless Steel | ||
| 27 | Nut (Stop Screw) | 2 | Stainless Steel |
Unit: N·m
Double-Acting Actuator
| Model | ||||||||||
| Air Supply Pressure(Unit:bar) | ||||||||||
| 2 | 2.5 | 3 | 4 | 4.5 | 5 | 5.5 | 6 | 7 | 8 | |
| RTO07DA(Φ32) | 3 | 4 | 5 | 6 | 7 | 8 | 9 | 10 | 11 | 12 |
| RTO12DA(Φ40) | 5 | 6 | 7 | 10 | 11 | 12 | 13 | 14 | 17 | 19 |
| RTO20DA(Φ52) | 8 | 10 | 12 | 16 | 18 | 20 | 22 | 24 | 28 | 32 |
| RTO35DA(Φ63) | 15 | 18 | 20 | 29 | 33 | 36 | 40 | 44 | 51 | 58 |
| RTO50DA(Φ75) | 20 | 25 | 30 | 40 | 45 | 50 | 55 | 60 | 70 | 80 |
| RTO75DA(Φ83) | 31 | 39 | 47 | 63 | 70 | 78 | 86 | 94 | 110 | 125 |
| RT110DA(Φ92) | 45 | 56 | 68 | 90 | 102 | 113 | 124 | 135 | 158 | 181 |
| RT160DA(Φ105) | 66 | 83 | 99 | 132 | 149 | 165 | 182 | 198 | 231 | 264 |
| RT255DA(Φ125) | 100 | 125 | 150 | 200 | 226 | 251 | 276 | 301 | 351 | 401 |
| RT435DA(Φ140) | 171 | 214 | 256 | 342 | 385 | 427 | 470 | 513 | 598 | 684 |
| RT665DA(Φ160) | 266 | 332 | 399 | 532 | 598 | 665 | 731 | 798 | 931 | 1064 |
| RT1000DA(Φ190) | 426 | 532 | 638 | 851 | 958 | 1064 | 1170 | 1277 | 1490 | 1702 |
| RT1200DA(Φ210) | 532 | 665 | 798 | 1064 | 1197 | 1330 | 1463 | 1596 | 1862 | 2128 |
| RT1800DA(Φ240) | 769 | 962 | 1154 | 1539 | 1731 | 1924 | 2116 | 2308 | 2693 | 3078 |
| RT2700DA(Φ270) | 1170 | 1462 | 1754 | 2339 | 2632 | 2924 | 3216 | 3509 | 4094 | 4679 |
| RT3800DA(Φ300) | 1526 | 1908 | 2289 | 3052 | 3434 | 3815 | 4197 | 4578 | 5341 | 6104 |
| RT5700DA(Φ350) | 2285 | 2856 | 3427 | 4570 | 5141 | 5712 | 6283 | 6854 | 7997 | 9139 |
| RT8000DA(Φ400) | 3256 | 4070 | 4884 | 6512 | 7326 | 8140 | 8954 | 9768 | 11396 | 13024 |
Sizing: Double Acting Actuator
The suggested safety factor for double acting actuators under
normal working conditions is 20%-30%.
Example:
©The torque needed by valve=100N·m
©The torque considered safety factor(1+30%)=130N·m
©Air Supply=5Bar
According to the above table, we can choose the minimum model is RT 160DA.
< Single-Acting Actuator
Air to port A forces the pistons outwards, causing the springs to compress The pinion turns counterclockwise while air is being exhausted from port B.
Loss of air pressure on port A, the stored energy in the springs forces the pistons inwards. The pinion turns clockwise while air is being exhausted fromport A.
Air to port B forces the pistons outwards, causing the springs to compress The pinion turns counterclockwise while air is being exhausted from port B.
Loss of air pressure on port A, the stored energy in the springs forces the pistons inwards. The pinion turns clockwise while air is being exhausted from port A.
Output Torque of Spring Return Actuators
Sizing:Spring Return Actuators
The suggested safety factor for spring return actuator under normal
working conditions is 30-50%
Example:
The torque needed by valve=80N·m
The torque consider safety factor(1+30%)=104 N·m
Air Supply=5BarAccording to the table of spring return actuators' output,
we find output torque of RT435SR K7 is:
Air stroke 0°=308N·m
Air stroke 90°=247N·m
Spring stroke 90°=181 N·m
Spring stroke 0°=120N·m
All the output torque is larger than we needed
| Output torque of air to springs | |||||||||||||||||||
| Air pressure | 2.5Bar | 3Bar | 4Bar | 5Bar | 6Bar | 7Bar | 8Bar | Springs'output | |||||||||||
| Model | 0° | 90° | 0° | 90° | 0° | 90° | 0° | 90° | 0° | 90° | 0° | 90° | 0° | 90° | 90° | 0° | |||
| Spring Qty | Start | End | Start | End | Start | End | Start | End | Start | End | Start | End | Start | End | End | Start | |||
| RT020SR(Φ52) | 5 | 5.7 | 3.8 | 7.6 | 5.7 | 6.2 | 4.3 | ||||||||||||
| 6 | 4.9 | 2.5 | 6.9 | 4.5 | 10.9 | 8.5 | 7.4 | 5.0 | |||||||||||
| 7 | 4.0 | 1.3 | 6.0 | 3.3 | 9.8 | 7.3 | 14.0 | 10.4 | 8.6 | 5.9 | |||||||||
| 8 | 5.2 | 2.0 | 9.2 | 6.0 | 13.2 | 9.1 | 17.2 | 14.1 | 9.9 | 6.7 | |||||||||
| 9 | 4.3 | 0.8 | 8.3 | 4.8 | 12.3 | 7.9 | 16.3 | 12.8 | 20.3 | 16.8 | 11.1 | 7.6 | |||||||
| 10 | 7.4 | 3.6 | 11.5 | 6.7 | 15.5 | 11.6 | 19.5 | 15.6 | 12.4 | 8.5 | |||||||||
| 11 | 6.6 | 2.3 | 10.6 | 5.4 | 14.6 | 10.4 | 18.6 | 14.3 | 22.6 | 18.3 | 13.6 | 9.3 | |||||||
| 12 | 9.7 | 4.2 | 13.8 | 9.1 | 17.8 | 12.2 | 21.8 | 17.1 | 14.8 | 10.2 | |||||||||
| 5 | 11.4 | 7.7 | 15.0 | 11.4 | 22.3 | 14.9 | 10.4 | 6.8 | |||||||||||
| 6 | 10.1 | 5.7 | 13.6 | 9.3 | 20.9 | 16.6 | 28.3 | 23.9 | 12.5 | 8.2 | |||||||||
| 7 | 8.6 | 3.6 | 12.5 | 7.2 | 19.5 | 14.5 | 26.8 | 21.9 | 14.6 | 9.6 | |||||||||
| RT035SR | 8 | 10.9 | 5.1 | 18.2 | 12.4 | 25.5 | 19.8 | 32.8 | 27.0 | 40.1 | 34.3 | 16.7 | 10.9 | ||||||
| (Φ63) | 9 | 16.8 | 10.4 | 24.1 | 17.7 | 31.4 | 24.9 | 38.7 | 32.2 | 18.8 | 12.3 | ||||||||
| 10 | 1.4 | 8.2 | 22.8 | 15.6 | 30.0 | 22.8 | 37.3 | 30.1 | 44.7 | 37.4 | 20.9 | 13.7 | |||||||
| 11 | 21.5 | 13.5 | 28.7 | 20.7 | 36.0 | 28.0 | 43.3 | 35.3 | 22.9 | 15.0 | |||||||||
| 12 | 20.0 | 11.4 | 27.3 | 18.6 | 34.6 | 25.9 | 41.9 | 33.3 | 25.0 | 16.4 | |||||||||
| 5 | 14.5 | 10.6 | 19.4 | 15.5 | 29.5 | 25.7 | 14.5 | 10.5 | |||||||||||
| 6 | 12.4 | 7.6 | 17.3 | 12.6 | 27.4 | 22.7 | 37.5 | 32.8 | 17.4 | 12.7 | |||||||||
| 7 | 10.4 | 4.8 | 15.2 | 9.7 | 25.3 | 19.9 | 35.4 | 29.9 | 20.3 | 14.8 | |||||||||
| RT050SR(Φ75) | 8 | 13.1 | 6.8 | 23.1 | 16.9 | 33.3 | 27.0 | 43.2 | 37.0 | 53.3 | 47.0 | 23.2 | 16.9 | ||||||
| 9 | 21.0 | 14.1 | 31.2 | 24.1 | 41.1 | 34.1 | 51.2 | 44.2 | 26.1 | 19.0 | |||||||||
| 10 | 19.0 | 11.1 | 28.8 | 21.2 | 39.0 | 31.2 | 49.1 | 41.2 | 59.1 | 51.2 | 29.0 | 21.1 | |||||||
| 11 | 27.0 | 18.3 | 37.0 | 28.3 | 47.0 | 38.4 | 57.0 | 48.4 | 31.9 | 23.2 | |||||||||
| 12 | 24.9 | 15.4 | 34.9 | 25.4 | 44.9 | 35.4 | 54.9 | 45.4 | 34.7 | 25.3 | |||||||||
| RT075SR(Φ83) | 5 | 23.3 | 16.1 | 31.1 | 24.0 | 46.8 | 39.7 | 23.0 | 15.8 | ||||||||||
| 6 | 20.1 | 11.5 | 28.0 | 19.3 | 43.7 | 35.1 | 59.4 | 50.7 | 27.6 | 19.0 | |||||||||
| 7 | 7.0 | 6.9 | 24.8 | 14.8 | 40.5 | 30.5 | 56.2 | 46.2 | 32.2 | 22.1 | |||||||||
| 8 | 21.7 | 10.1 | 37.4 | 25.8 | 53.1 | 41.5 | 68.8 | 57.2 | 84.5 | 72.9 | 36.8 | 25.3 | |||||||
| 9 | 34.2 | 21.3 | 49.9 | 37.0 | 65.6 | 52.6 | 81.2 | 68.3 | 41.4 | 28.5 | |||||||||
| 10 | 31.0 | 16.6 | 46.7 | 32.3 | 62.4 | 48.0 | 78.1 | 63.7 | 93.8 | 79.3 | 46.0 | 31.6 | |||||||
| 11 | 43.6 | 27.7 | 59.3 | 43.4 | 75.0 | 59.1 | 90.6 | 74.8 | 50.6 | 34.8 | |||||||||
| 12 | 40.4 | 23.2 | 56.1 | 38.9 | 71.7 | 54.5 | 87.4 | 70.2 | 55.2 | 38.0 | |||||||||
| RT110SR(Φ92) | 5 | 33.1 | 22.0 | 44.2 | 33.2 | 66.8 | 55.9 | 34.4 | 23.3 | ||||||||||
| 6 | 28.4 | 15.2 | 39.6 | 26.4 | 62.2 | 49.0 | 84.8 | 71.6 | 41.2 | 28.0 | |||||||||
| 7 | 23.8 | 8.2 | 34.9 | 19.4 | 57.5 | 42.1 | 80.2 | 64.7 | 48.1 | 32.7 | |||||||||
| 8 | 31.3 | 12.6 | 52.9 | 35.2 | 75.5 | 57.9 | 98.1 | 80.5 | 120.7 | 103.0 | 55.0 | 37.3 | |||||||
| 9 | 48.2 | 28.4 | 70.9 | 51.0 | 93.5 | 73.6 | 116.0 | 96.1 | 61.9 | 42.0 | |||||||||
| 10 | 43.6 | 21.5 | 66.2 | 44.1 | 88.8 | 66.7 | 111.3 | 89.2 | 134.0 | 111.8 | 68.7 | 46.7 | |||||||
| 11 | 61.5 | 37.2 | 84.1 | 59.9 | 106.6 | 82.4 | 129.2 | 105.0 | 75.6 | 51.4 | |||||||||
| 12 | 56.8 | 30.4 | 79.4 | 53.0 | 101.9 | 75.5 | 124.5 | 98.1 | 82.5 | 56.0 | |||||||||
| RT160SR(Φ105) | 5 | 51.0 | 33.4 | 67.5 | 49.9 | 100.6 | 83.0 | 49.2 | 31.6 | ||||||||||
| 6 | 44.7 | 23.5 | 61.1 | 40.0 | 94.2 | 73.2 | 127.3 | 106.2 | 59.1 | 38.0 | |||||||||
| 7 | 38.4 | 13.7 | 54.9 | 30.3 | 87.9 | 63.4 | 121.0 | 96.4 | 68.9 | 44.3 | |||||||||
| 8 | 48.5 | 20.4 | 81.6 | 53.5 | 114.7 | 86.5 | 147.7 | 119.6 | 180.8 | 152.7 | 78.7 | 50.6 | |||||||
| 9 | 75.3 | 43.7 | 108.4 | 76.8 | 141.5 | 109.8 | 174.5 | 142.9 | 88.6 | 56.9 | |||||||||
| 10 | 68.9 | 33.4 | 102.0 | 66.5 | 135.1 | 99.6 | 168.2 | 132.6 | 201.2 | 165.7 | 98.4 | 63.3 | |||||||
| 11 | 95.7 | 57.0 | 128.7 | 90.1 | 161.8 | 123.1 | 194.8 | 156.2 | 108.3 | 69.6 | |||||||||
| 12 | 89.4 | 47.5 | 122.5 | 80.6 | 155.5 | 113.6 | 188.6 | 146.7 | 118.1 | 75.9 | |||||||||
| RT255SR(Φ125) | 5 | 73 | 47 | 98 | 72 | 148 | 122 | 79 | 52 | ||||||||||
| 6 | 63 | 31 | 88 | 56 | 138 | 107 | 188 | 157 | 94 | 63 | |||||||||
| 7 | 52 | 15 | 77 | 40 | 127 | 90 | 178 | 141 | 110 | 73 | |||||||||
| 8 | 67 | 25 | 117 | 75 | 167 | 125 | 217 | 176 | 268 | 226 | 125 | 84 | |||||||
| 9 | 107 | 59 | 157 | 109 | 207 | 159 | 257 | 210 | 141 | 94 | |||||||||
| 10 | 96 | 44 | 146 | 94 | 196 | 144 | 247 | 194 | 297 | 245 | 157 | 105 | |||||||
| 11 | 136 | 78 | 186 | 128 | 236 | 178 | 286 | 228 | 173 | 115 | |||||||||
| 12 | 125 | 63 | 176 | 113 | 226 | 163 | 276 | 213 | 188 | 125 | |||||||||
N·m
| Output torque of air to springs | ||||||||||||||||||
| Air pressure | 2.5Bar | 3Bar | 4Bar | 5Bar | 6Bar | 7Bar | 8Bar | Springs'output | ||||||||||
| Model | 0° | 90° | 0° | 90° | 0° | 90° | 0° | 90° | 0° | 90° | 0° | 90° | 0° | 90° | 90° | 0° | ||
| Spring Qty | Start | End | Start | End | Start | End | Start | End | Start | End | Start | End | Start | End | End | Start | ||
| 128 | 85 | 171 | 127 | 256 | 213 | 129 | 86 | |||||||||||
| 56 | 117 | 59 | 154 | 102 | 239 | 187 | 325 | 273 | 155 | 103 | ||||||||
| 7 | 94 | 33 | 137 | 76 | 222 | 162 | 308 | 247 | 181 | 120 | ||||||||
| RT435SR(Φ140) | 8 | 120 | 50 | 205 | 136 | 291 | 221 | 376 | 307 | 462 | 392 | 206 | 137 | |||||
| 9 | 187 | 110 | 273 | 196 | 358 | 281 | 444 | 367 | 232 | 155 | ||||||||
| 10 | 170 | 84 | 256 | 169 | 341 | 255 | 427 | 340 | 512 | 426 | 258 | 172 | ||||||
| 11 | 238 | 143 | 324 | 229 | 409 | 314 | 495 | 400 | 284 | 189 | ||||||||
| 12 | 221 | 118 | 307 | 203 | 392 | 289 | 478 | 374 | 310 | 206 | ||||||||
| 5 | 193 | 124 | 259 | 191 | 392 | 324 | 208 | 140 | ||||||||||
| 6 | 165 | 83 | 232 | 149 | 365 | 282 | 498 | 415 | 250 | 168 | ||||||||
| 7 | 137 | 41 | 203 | 107 | 336 | 240 | 469 | 373 | 292 | 196 | ||||||||
| RT665SR | 8 | 176 | 66 | 309 | 199 | 442 | 237 | 575 | 465 | 708 | 598 | 333 | 223 | |||||
| (Φ160) | 9 | 280 | 157 | 413 | 290 | 546 | 423 | 679 | 556 | 375 | 251 | |||||||
| 10 | 253 | 115 | 386 | 248 | 519 | 381 | 652 | 514 | 785 | 647 | 417 | 279 | ||||||
| 11 | 358 | 207 | 491 | 340 | 624 | 473 | 757 | 606 | 458 | 307 | ||||||||
| 12 | 330 | 165 | 463 | 298 | 596 | 431 | 729 | 564 | 500 | 335 | ||||||||
| 5 | 332 | 222 | 438 | 329 | 651 | 542 | 309 | 200 | ||||||||||
| 6 | 292 | 16 | 398 | 267 | 611 | 480 | 824 | 693 | 371 | 240 | ||||||||
| 7 | 252 | 199 | 358 | 205 | 571 | 418 | 784 | 631 | 433 | 280 | ||||||||
| RT1000SR | 8 | 318 | 143 | 531 | 356 | 744 | 569 | 957 | 782 | 1169 | 995 | 495 | 320 | |||||
| (Φ190) | 9 | 491 | 295 | 704 | 507 | 917 | 720 | 1130 | 933 | 557 | 360 | |||||||
| 10 | 451 | 233 | 664 | 446 | 877 | 658 | 1090 | 871 | 1302 | 1084 | 618 | 400 | ||||||
| 11 | 624 | 384 | 837 | 579 | 1050 | 809 | 1263 | 1022 | 680 | 440 | ||||||||
| 12 | 584 | 322 | 797 | 535 | 1010 | 748 | 1223 | 960 | 742 | 480 | ||||||||
| 5 | 390 | 285 | 523 | 418 | 789 | 684 | 380 | 275 | ||||||||||
| 6 | 335 | 209 | 468 | 342 | 734 | 608 | 1000 | 874 | 456 | 330 | ||||||||
| 7 | 280 | 133 | 413 | 266 | 679 | 532 | 945 | 798 | 532 | 385 | ||||||||
| RT1200SR | 8 | 358 | 190 | 624 | 456 | 890 | 722 | 1156 | 988 | 1422 | 1254 | 608 | 440 | |||||
| (Φ210) | 9 | 569 | 380 | 835 | 646 | 1101 | 912 | 1367 | 1178 | 684 | 495 | |||||||
| 10 | 514 | 304 | 780 | 570 | 1046 | 836 | 1312 | 1102 | 1578 | 1368 | 760 | 550 | ||||||
| 11 | 725 | 494 | 991 | 760 | 1257 | 1026 | 1523 | 1292 | 836 | 605 | ||||||||
| 12 | 670 | 418 | 936 | 684 | 1202 | 950 | 1468 | 1216 | 912 | 660 | ||||||||
| 5 | 552 | 109 | 744 | 600 | 1129 | 985 | 554 | 410 | ||||||||||
| 6 | 470 | 297 | 662 | 489 | 1047 | 874 | 1432 | 1259 | 665 | 492 | ||||||||
| 7 | 388 | 187 | 580 | 379 | 964 | 764 | 1349 | 1149 | 775 | 575 | ||||||||
| RT1800SR | 8 | 498 | 268 | 883 | 653 | 1267 | 1037 | 1652 | 1422 | 2037 | 1807 | 886 | 656 | |||||
| (Φ240) | 9 | 800 | 542 | 1185 | 926 | 1569 | 1311 | 1954 | 1696 | 998 | 739 | |||||||
| 10 | 718 | 431 | 1103 | 816 | 1488 | 1201 | 1872 | 1586 | 2257 | 1970 | 1108 | 821 | ||||||
| 11 | 1021 | 705 | 1406 | 1090 | 1791 | 1474 | 2176 | 1859 | 1219 | 903 | ||||||||
| 12 | 939 | 594 | 1323 | 979 | 1708 | 1363 | 2093 | 1748 | 1330 | 985 | ||||||||
| 5 | 903 | 675 | 1195 | 968 | 1779 | 1552 | 787 | 560 | ||||||||||
| 6 | 790 | 519 | 1083 | 811 | 1667 | 1396 | 2252 | 1981 | 943 | 672 | ||||||||
| 7 | 679 | 361 | 972 | 654 | 1556 | 1238 | 2141 | 1823 | 1101 | 783 | ||||||||
| RT2700SR | 8 | 860 | 497 | 1444 | 1081 | 2029 | 1666 | 2614 | 2252 | 3199 | 2836 | 1258 | 895 | |||||
| (Φ270) | 9 | 1332 | 923 | 1917 | 1509 | 2502 | 2094 | 3087 | 2678 | 1416 | 1007 | |||||||
| 10 | 1220 | 767 | 1805 | 1352 | 2390 | 1937 | 2974 | 2521 | 3560 | 3107 | 1572 | 1119 | ||||||
| 11 | 1693 | 1194 | 2278 | 1779 | 2862 | 2364 | 3448 | 2949 | 1730 | 1231 | ||||||||
| 12 | 1582 | 1037 | 2167 | 1623 | 2751 | 2207 | 3336 | 2792 | 1887 | 1342 | ||||||||
| 5 | 1097 | 729 | 1061 | 730 | ||||||||||||||
| 6 | 935 | 494 | 1316 | 875 | 1273 | 876 | ||||||||||||
| 7 | 772 | 258 | 1153 | 639 | 1916 | 1402 | 1485 | 122 | ||||||||||
| RT3800SR | 8 | 991 | 403 | 1754 | 1166 | 2517 | 1929 | 1697 | 1168 | |||||||||
| 9 | 1592 | 930 | 2355 | 1693 | 3118 | 2456 | 1909 | 1314 | ||||||||||
| 10 | 1430 | 695 | 2193 | 1458 | 2956 | 2221 | 3719 | 2984 | 4482 | 3747 | 2122 | 1460 | ||||||
| 11 | 2030 | 1222 | 2793 | 1985 | 3556 | 2748 | 4319 | 3511 | 2334 | 1606 | ||||||||
| 12 | 1868 | 986 | 2631 | 1749 | 3394 | 2512 | 4157 | 3275 | 2546 | 1752 | ||||||||
| 5 | 1553 | 964 | 1702 | 1173 | ||||||||||||||
| 6 | 1292 | 586 | 1863 | 1157 | 2043 | 1408 | ||||||||||||
| 7 | 1031 | 208 | 1602 | 779 | 2745 | 1922 | 2353 | 1642 | ||||||||||
| RT5700SR(Φ350) | 8 | 1341 | 401 | 2484 | 1544 | 3626 | 2686 | |||||||||||
| 9 | 2224 | 1165 | 3336 | 2307 | 4508 | 3449 | 3064 | 2112 | ||||||||||
| 10 | 1963 | 787 | 3105 | 1929 | 4247 | 3071 | 5390 | 4214 | 6532 | 5356 | 3405 | 2346 | ||||||
| 11 | 2844 | 1551 | 3986 | 2693 | 5129 | 3836 | 6271 | 4978 | 3745 | 2581 | ||||||||
| 12 | 2584 | 1172 | 3726 | 2314 | 4869 | 3457 | 6011 | 4599 | 4086 | 2816 | ||||||||
| 7 | 2028 | 869 | 2880 | 1837 | ||||||||||||||
| 8 | 1736 | 411 | 2550 | 1225 | 3292 | 2100 | ||||||||||||
| 9 | 2259 | 768 | 3887 | 2396 | 3703 | 2362 | ||||||||||||
| RT8000SR(Φ400) | 10 | 1967 | 311 | 3595 | 1939 | 5223 | 3567 | 4115 | 2624 | |||||||||
| 11 | 3303 | 1482 | 4931 | 3110 | 6559 | 4738 | 4526 | 2887 | ||||||||||
| 12 | 3012 | 1025 | 4640 | 2653 | 6268 | 4281 | 7895 | 5908 | 9523 | 7536 | 4938 | 3149 | ||||||
| 13 | 4348 | 2195 | 5976 | 3823 | 7603 | 5450 | 9231 | 7078 | 5349 | 3412 | ||||||||
| 14 | 4057 | 1738 | 5685 | 3366 | 7312 | 4993 | 8940 | 6621 | 5761 | 36743937 | ||||||||
| 15 | 3765 | 1281 | 5393 | 2909 | 7020 | 4536 | 8648 | 6164 | 6172 | |||||||||
| 16 | 5101 | 2452 | 6728 | 4079 | 8356 | 5707 | 6584 | 4199 | ||||||||||
Installation Guide
Overall Dimensions
RT007DA
| Model | A | B | C | D | E | F | G | H | I | J | K | L | M | N | z | φ | AirConnection |
| RT020(Φ52) | 30 | 41.5 | 65.5 | 72 | 92 | 65 | 30 | 80 | Φ36 | Φ50 | M5*8 | M6*10 | 11 | 14 | 147 | Φ40 | NAMUR G1/4" |
| RT035(Φ63) | 36 | 47 | 81 | 87.5 | 107.5 | 72 | 30 | 80 | Φ50 | Φ70 | M6*10 | M8*13 | 14 | 18 | 168 | Φ40 | NAMUR G1/4" |
| RT050(Φ75) | 42 | 53 | 94 | 99.51 | 19.5 | 81 | 30 | 80 | Φ50 | Φ70 | M6*10 | M8*13 | 14 | 18 | 184 | Φ40 | NAMUR G1/4" |
| RT075(Φ83) | 46 | 57 | 98.5 | 108.71 | 28.7 | 92 | 30 | 80 | Φ50 | Φ70 | M6*10 | M8*13 | 17 | 21 | 204 | Φ40 | NAMUR G1/4" |
| RT110(Φ92) | 50 | 58.5 | 111 | 136.5 | 98 | 30 | 80 | Φ50 | Φ70 | M6*10 | M8*13 | 17 | 21 | 262 | Φ40 | NAMUR G1/4" | |
| RT160(Φ105) | 57.5 | 64 | 122.5 | 133 | 153 | 109.5 | 30 | 80 | Φ70 | Φ102 | M8*13 | M10*16 | 22 | 26 | 268 | Φ40 | NAMUR G 1/4" |
| RT255(Φ125) | 67.5 | 74.5 | 145.5 | 155 | 175 | 127.5 | 30 | 130 | Φ70Φ | 102 | M8*13 | M10*16 | 22 | 26 | 301 | Φ55 | NAMUR G1/4" |
| RT435(Φ140) | 75 | 77 | 161 | 172 | 192 | 137.5 | 30 | 130 | Φ102Φ | 125 | M10*16 | M12*20 | 27 | 31 | 390 | Φ55 | NAMUR G1/4" |
| RT665(Φ160) | 87 | 87 | 184 | 197 | 217 | 158 | 30 | 130Φ | 102 Φ | 125 | M10*16 | M12*20 | 27 | 31 | 458 | Φ55 | NAMUR G1/4" |
| RT1000(Φ190) | 103 | 103 | 213 | 230 | 260 | 189 | 30 | 130 | Φ140 | M16*25 | 36 | 40 | 525 | Φ80 | NAMUR G1/4" | ||
| RT1200(Φ210) | 113 | 113 | 235.5 | 255 | 285 | 210 | 30 | 130 | Φ140 | M16*25 | 36 | 40 | 532 | Φ80 | NAMUR G1/4" | ||
| RT1800(Φ240) | 130 | 1302 | 64.5 | 289 | 319 | 245 | 30 | 130 | Φ165 | M20*25 | 46 | 50 | 602 | Φ80 | NAMUR G1/4" | ||
| RT2700(Φ270) | 147 | 147 | 299 | 326 | 356 | 273 | 30 | 130 | Φ165 | M20*25 | 46 | 50 | 722 | Φ80 | NAMUR G1/2" | ||
| RT3800(Φ300) | 162 | 162 | 348 | 348 | 378 | 324 | 30 | 130 | Φ165Φ | 215 | M20*25 | M20*25 | 46 | 60 | 742 | Φ80 | NAMUR G1/2" |
| RT5700(Φ350) | 190 | 190 | 402 | 402 | 432 | 380 | 30 | 130Φ | 165 Φ | 215 | M20*25 | M20*25 | 55 | 60 | 860 | Φ80 | NAMUR G1/2" |
| RT8000(Φ400) | 258 | 258 | 464 | 464 | 494 | 298 | 30 | 130 | Φ165Φ | 254 | M20*258 | *M16*25 | 55 | 60 | 924 | Φ80 | NAMUR G1/2" |
Actuator Selection based on Torque Curves
In the selection process of actuators, if we can understand the torque required for valve selection and operation, we can choose actuators more economically and reasonably.
Single-acting Actuator Spring Mounting Forms
Weight Table (Net Weight)
| Model | RT007 | RT012 | RT020 | RT035 | RT050 | RT075 | RT110 | RT160 | RT255 |
| Cylinder Dia. | Φ32 | Φ40 | Φ52 | Φ63 | Φ75 | Φ83 | Φ92 | Φ105 | Φ125 |
| DA | 0.70 | 1.00 | 1.35 | 1.95 | 2.56 | 3.28 | 4.58 | 5.89 | 8.94 |
| SRK12 | 、 | 1.10 | 1.48 | 2.12 | 2.83 | 3.69 | 5.35 | 6.72 | 10.32 |
| Model | RT435 | RT665 | RT1000 | RT1200 | RT1800 | RT2700 | RT3800 | RT5700 | RT8000 |
| Cylinder Dia. | Φ140 | Φ160 | Φ190 | Φ210 | Φ240 | Φ270 | Φ300 | Φ350 | Φ400 |
| DA | 13.43 | 19.96 | 34.99 | 46.77 | 54.16 | 77.17 | 106.53 | 160.07 | 181.94 |
| SRK12 | 15.84 | 23.73 | 41.93 | 55.94 | 67.03 | 98.29 | 133.94 | 209.10 | 225.46 |
Air Consumption
| Model | Air Volume Opening | Air Volume Closing | Model | Air Volume Opening | Air Volume Closing |
| Rt007 | 0.04 | 0.05 | RT435 | 2.5 | 2.2 |
| RT012 | 0.08 | 0.11 | RT665 | 3.7 | 3.2 |
| RT020 | 0.12 | 0.16 | RT1000 | 5.9 | 5.4 |
| RT035 | 0.21 | 0.23 | RT1200 | 7.5 | 7.5 |
| RT050 | 0.3 | 0.34 | RT1800 | 11 | 9 |
| RT075 | 0.43 | 0.47 | RT2700 | 17 | 14 |
| RT110 | 0.64 | 0.73 | RT3800 | 23.8 | 29.7 |
| RT160 | 0.95 | 0.88 | RT5700 | 35.1 | 46.3 |
| RT255 | 1.6 | 1.4 | RT8000 | 52.6 | 56 |
120°/135°/180° Double-Acting Actuator:
In order to meet the requirements of different valves and mechanical automation equipment, we can customize pneumatic actuators with different travel angles (120°, 135°, 180°) according to customer requirements.
Output Torque
For the output torque of double-acting actuators, please refer to the torque chart for 90° actuators.
| Size | RTO20180° | RT035180° | RTO50180° | RT075180° | RT110180° | RT160180° | RT255180° | RT435180° | RT665180° | RT1000180° | RT1200180° |
| Z(mm) | 213 | 243 | 258 | 298 | 362 | 386 | 429 | 569 | 652 | 756 | 760 |
The sizes of 120°, 135° actuators are the same as 180° actuators.
3-Position Pneumatic Actuator
Three-Position pneumatic actuator provides three operating positions: 0°, 45°,90°or 0°,90°,180°. The intermediate position is achieved by mechanical stops generated by 2 auxiliary pistons. The intermediate position is adjustable. For example, a 90°actuator allow the intermediate position to be adjusted to 20°, 30°, 50°, 70°etc.
Output Torque
For the output torque of double-acting actuators, please refer to the torque chart for 90°actuators.
| Size | RTO20-3P | RT035-3P | RT050-3P | RT075-3P | RT110-3P | RT160-3P | RT255-3P | RT435-3P | RT665-3P | RT1000-3P | RT1200-3P |
| Z(mm) | 266 | 303 | 306 | 336 | 394 | 410 | 456 | 570 | 646 | 788 | 788 |
Working Principle of 3-Position Actuators
| 0° | 90° | 30° | 0° | |
| Solenoid valve1 | OFF | ON | OFF | OFF |
| Solenoid valve2 | OFF | OFF | ON | OFF |
| 0° | 90° | 30° | 0° | |
| Solenoid valve1 | OFF | OFF | OFF | OFF |
| Solenoid valve2 | ON | OFF | ON | ON |
| Solenoid valve3 | OFF | ON | ON | OFF |
Working Principle of 3-Position Pneumatic Actuators
| 0° | 30° | 90° | 30° | 0° | |
| Solenoid valve1 | OFF | ON | OFF | ON | OFF |
| Solenoid valve2 | OFF | ON | ON | ON | OFF |
| Size | RT007 | RT012 | RT020 | RT035 | RT050 | RT075 | RT110 | RT160 | RT255 | |||||||||
| DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | |
| 0°-90° | 0.2 | 0.2 | 0.8 | 0.3 | 0.9 | 0.3 | 0.9 | 0.3 | 1 | 0.4 | 1.2 | 0.5 | 1.2 | 0.7 | 1.4 | 0.8 | 1.5 | |
| 90°-0° | 0.2 | 0.2 | 0.5 | 0.2 | 0.5 | 0.25 | 0.5 | 0.3 | 0.6 | 0.4 | 0.6 | 0.5 | 0.6 | 0.7 | 0.8 | 0.9 | 1 | |
| Size | RT435 | RT665 | RT1000 | RT1200 | RT1800 | RT2700 | RT3800 | RT5700 | RT8000 | |||||||||
| DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | DA | SR | |
| 0°-90° | 1.3 | 2.5 | 2.2 | 2.6 | 2.8 | 3.4 | 2.8 | 3.6 | 3 | 4 | 3.5 | 5 | 4 | 6 | 5 | 8 | 8 | 12 |
| 90°-0° | 1.5 | 1.4 | 2.4 | 1.5 | 3.5 | 1.8 | 3.3 | 2.5 | 3.3 | 2.8 | 3.8 | 3 | 4.5 | 4 | 5.5 | 5 | 8.5 | 8 |
(1) RT007-RT1000, clean air source, air source pressure 5Bar, normal temperature, actuator without load, stroke 90°, test solenoid valve: 4M310- 10, air source pipe: 8mm
Operating Conditions
1. Operating Media:
Dry or lubricated air, or the non-corrosive gases The maximum particle diameter must less than 30 vm
2. Air Supply Pressure
The minimum supply pressure is 2.5 Bar, The maximum supply pressure is 8 Bar
3. Operating Temperature
Standard: - 2 0 ^ { \circ } C ~ + 8 0 ^ { \circ } C
Low Temperature: 3 5 ^ { \circ } C ~ + 8 0 ^ { \circ } C ^ { \circ } C
High Temperature: - 1 5 ^ { \circ } ( \mathsf { C } ~ + 1 5 0 ^ { \circ } \mathsf { C }
4. Travel Adjustment
Have adjustment range of ±5° for the rotation at 0 ^ { \circ } and 9 0 ^ { \circ }
5. Application
Either indoor or outdoor
Unit:mm
| Model | RT007 | RT012 | RT020 | RT035 | RT050 | RT075 | RT110 | RT160 | RT255 |
| Cylinder | Φ32 | Φ40 | Φ52 | Φ63 | Φ75 | Φ83 | Φ92 | Φ105 | Φ125 |
| Model | RT435 | RT665 | RT1000 | RT1200 | RT1800 | RT2700 | RT3800 | RT5700 | RT8000 |
| Cylinder | Φ140 | Φ160 | Φ190 | Φ210 | Φ240 | Φ270 | Φ300 | Φ350 | Φ400 |
Ordering Information
RT series valve pneumatic actuator is a complex automatic control device, which consists of pneumatic actuator, valve and various pneumatic components and accessories. Users can carefully select each component according to the needs of on-site control and clearly indicate it in the technical contract.
Pneumatic Actuators
Air source pressure, action mode, cylinder thrust, full travel time, connecting bracket and manual mechanism;
Valves
Specification model, nominal pressure, nominal size, valve thrust, flow medium, actual working pressure, use temperature, installation position;
Filter Pressure Reducing Valve
Brand and model, oil mist, automatic drainage, operating temperature, valve body and pressure gauge material, air source interface size;
Solenoid Valve
Brand and model, double-acting or single-acting, single or double electric control, two-position three-way or two-position five-way, voltage, power, protection level, explosion-proof level, electrical interface size, air source interface size, operating temperature, manual operation;
Travel Switch
Brand and model, mechanical or proximity, DPDT or SPDT or P&F, protection level, explosion-proof level, electrical interface size, accessory material;
Other Annexes
Pneumatic control valve, one-way valve, quick discharge valve, speed regulating valve, lock valve, speed increasing amplifier, etc.;
Special Requirements
If you have special requirements,such as material, paint, interface size, installationspace, etc., please contact IKNOW sales representative in time;
Locator
Brand and model, double-acting or single-acting, protection level, explosion-proof level, input signal, output signal, feedback signal, feedback bracket, HART module, LED display, use temperature, accessory material;
Installation and Operation
The pneumatic actuator undergoes necessary performance tests and calibration according to order requirements before leaving the factory, making it ready for direct installation and use. Its bottom mounting hole design complies with ISO 5211 standard, facilitating straightforward bracket installation.
Upon unpacking, inspect the product for any unexpected damage and ensure all accompanying parts are complete. Particularly for products stored over extended periods, comprehensive maintenance is necessary before installation and use.
Prior to installing the actuator with valves, verify the actuator's model specifications to ensure its thrust requirements align with those needed by the valves.
Before installation, check the compatibility of the actuator's bracket flange dimensions with the valve and ensure sufficient installation space.
If using pneumatic/manual switching mechanisms, verify postinstallation that the switching mechanism operates as required to prevent inadvertent operation. For valves equipped with manual operating mechanisms, during spring return (valve closure) or pneumatic opening/closing processes, avoid any "pneumaticmanual" switching operations at any valve position.
If using pneumatic/manual switching mechanisms, before manual operation, ensure residual air within the cylinder is purged (only if residual air is present) through the solenoid valve (or control component). Confirm correct manual operation before conducting pneumatic operational trial checks.
©When using the handwheel for operation with pneumatic/manual switching mechanisms, take care not to exert excessive force and strictly prohibit the use of any external tools directly on the manual mechanism to prevent equipment damage or personal injury.
Maintenance and Care
To ensure the proper functioning of the entire pneumatic instrument control system, pneumatic actuators should undergo monthly inspections and annual comprehensive maintenance. Additionally, keep the exterior of actuators clean, free from dust and oil contamination.
Ensure excellent sealing performance of actuators by maintaining intact, secure, and tight sealing surfaces and points.
Regularly inspect all parts of cylinders and air piping systems to ensure no air leakage at pipe connections and maintain air source pressure within normal range. Ensure air pipes are free from dents and remain unobstructed.
During maintenance, carefully inspect and clean cylinder sleeves and pistons. Replace damaged or aged O-ring seals immediately. Apply lubricating oil evenly on cylinder walls and seal groove before cautiously inserting the piston to prevent damage to O-ring seals.
For complete pneumatic valves equipped with pneumatic/manual switching devices, ensure smooth manual operation and welllubricated manual operating mechanisms. Lubricate bearings and drive parts on the switching shaft every three months or semiannually to maintain normal operation.
Maintain air source pressure within the range of 0.3-0.8 MPa (G) and ensure purified air through dust removal and dehydration treatments. Regularly drain and purge air filters associated with actuators to prevent impurities from entering solenoid valves and affecting their normal operation.
Ensure electrical signal wires are free from faults such as missing phases, short circuits, or open circuits. Securely connect protective housing joints to prevent water and dust corrosion.
Ensure proper installation of stuffing box covers without tilting to prevent friction on valve stems leading to jamming, thereby ensuring actuators operate flexibly and normally.
Common Faults and Remedies
| Failure PhenomenonValve does not move | Check Item | Method of Exclusion |
| Whether the solenoid valve is normal, whether the coil is burned out,whether the solenoid valve core is stuck by dirt | Replace solenoid valve, replace coil,remove dirt | |
| Separately supply air to the actuator and check whether it is workingproperly.Open the actuator to check whether the seal is damagedand the inner surface of the cylinder is damaged | Replace the damaged seal ring,replace the cylinder | |
| Impurities in the valve jam the ball core | Remove impurities and replacevalve parts | |
| The handle of the manual operating mechanism is in the manualposition | Move the handle to the automaticposition | |
| Valve action isslow and crawling | Insufficient air pressure | Increase air pressure |
| Pneumatic actuator thrust is too small | Increase actuator model specifications | |
| The valve core or other valve parts are too tight and unreasonable | Repair assembly, adjust thrust | |
| The air supply pipeline is blocked and the flow is too small | Eliminate blockage | |
| No signal from echo | Signal power line, short circuit, open circuit | Repair power lines |
| Inaccurate position of concave wheel | Adjust the concave wheel to the correctposition | |
| Damaged micro switch | Replace the micro switch |
After-sales service
Pre-sales service
a. Professional Consultation and Answers: We provide deep analysis of customer needs, offering detailed and professional answers to questions regarding products, technology, and applications.
b. Precise Selection and Quotation: Based on specific customer requirements, we provide precise matching and competitive pricing for pneumatic actuators and accessories.
c.Comprehensive Technical Support: We provide comprehensivetechnical support, including outline drawings, pneumatic (electrical) circuit diagrams, and instruction manuals, as well as value-added services such as conferences and training.
Sales Services
a. Efficient Order Processing: We respond quickly and process customer orders, ensuring pneumatic actuators are delivered to customers on time, in good quality and correct quantity.
b. Installation and Commissioning Services: We provide installation and commissioning services for pneumatic actuators and accessories. We ensure the pneumatic circuitry fully meets the customer's on-site usage requirements.
c. One-Stop Solution:We provide customers with a complete service from selection, installation, and commissioning of pneumatic actuators and valves, simplifying the purchasing process and reducing the difficulty of selection for customers.
After-sales Service
a. Long-term Quality Guarantee:We provide customers with a 12-monthquality guarantee, ensuring the stability and reliability of product quality.
b. Rapid Response:We promise to respond quickly within12 hours of receiving a customer service request and provide an effective solution, reducing customer waiting time.
c. Continuous Technical Support:We provide customers with product usage training and technical guidance to ensure they fully master the operation procedures of pneumatic lubrication gates, optimizing the customer experience.
Fireproof shield can be installed on actuators.
Flexible fireproof shield: A professional product for fire protection of industrial equipment, capable of withstanding temperatures up to 1093°C.
Utilizing a composite insulation structure of ceramic fiber and silicone rubber, it offers flexible installation and is also used in petrochemical and other industries for similar applications.
Sincerely Recruit National Agents
IKNOW ACTUATOR CO.,LTD
ADD: No. 2367, Binhai 1lth Road, Wenzhou Bay New Area, Zhejiang Province
TEL:+86-577-8692 7222 8582 5555
E-mail: iknow@iknow-control.com
cn.iknow-control.com400-111-8080