Wehaveadvanced production testing equipmentestablished in-housetestingstationsand providereliable guarantees forproducing high-quality products withexquisitecraftsmanshipandrigorousmanagementconcepts. Wehaveestablishedastrictmanagement systembasedonGB/T9ool"QualityManagementSystemRequirements", GB/T24001 "Environmental Management System Requirementsand Guidelines for Use",and OHSAS18001 "Occupational Healthand SafetyManagementSystem-Requirements";Adheretothequalityserviceconceptof "meticulousproductsandsincerecustomers",pursuetheimprovementofproductqualityandservicequalityand wholeheartedlyprovideuserswithzerodefectproductsand"Saiaoisbyyourside"zerodistanceefficient star service.
TUOYAEEesitytygii continuouslyimprovingproductqualityandsincerelyooperatingwithnewandoldcustomerswithighqualityand reliableproductsandfastand thoughtfulservices.Tocontributetothedevelopmentofanewgenerationofsafe reliable,and high-performance electrical equipment.
Contents
CircuitBreaker& AutomaticTransferSwitch
YTCM1SeriesMouldedCaseCircuitBreaker. .01-05
YTCM1LSeriesEarthLeakageCircuitBreaker .06-10
TYW1IntelligentCircuit Breaker.. .11-17
DualPowerAutomaticTransferSwitch .18-26
surgeprotectors .27
1. Application
YTCM1 series moulded case circuit breaker is one of products developed and manufactured by adopting international advanced technology.It is supplied with rated insulating voltage 550 and 800Vandused forcircuitofAC 5 0 / 6 0 \mathsf { H z } ,ratedoperatingvoltageAC4ooV(orbelow),rated operating current up to 16o0Afor infrequent changing overand starting of the motors.The prod
2.MainTechnicalSpecification
YTCM1-125L/3P
| Type | Rated current (A) | Pole | insul- ating volt- age (V) | RatedRated operat- ing volt- age (V) | Arcing- over distance (mm) | Ultimate short circuit breaking capacity | Servies short circuit breaking capacity | Operation perform- ance | Utiliza- tion cat- egory | |
| LoadUnload | ||||||||||
| YTCM1-63L | (6),10,16,20, 25,32,40,50,63 | (10),16,20,25, 32,40,50,63, 80,100 | 0 | (kA) 25 | (kA) 18 | 1500 | 8500 | |||
| YTCM1-63M | 500V | 0 | 50 | 35 | ||||||
| YTCM1-100L | 0 50) | 35 | 22 | |||||||
| YTCM1-100M | 0 50) | 50 | 35 | |||||||
| YTCM1-100H | 50) | 85 | 50 | |||||||
| YTCM1-225L | 3,4 | 50 35 | 22 1000 | |||||||
| YTCM1-225M | 50 | 50 | 35 | |||||||
| YTCM1-225H | 50 | 85 | 50 | 1000 4000 | ||||||
| YTCM1-400L | 225,250,315, 350,400 | 50 400V | 50 | 35 | ||||||
| YTCM1-400M | 400 500 | 800V | 100 | 65 | 42 | |||||
| YTCM1-630L | 100 | 50 | 35 | |||||||
| YTCM1-630M | 100 | 65 | 42 | |||||||
| YTCM1-630H | 100 | 100 | 65 | |||||||
| YTCM1-800M | 630,700,800 | 3 1000,1250 | 100 | 75 | 50 | |||||
| YTCM1-800H | 100 100 | 65 | ||||||||
| YTCM1-1250M | 100 | 100 | 65 | |||||||
| YTCM1-1250H | 100 | 125 | 75 | |||||||
| YTCM1-1600M | 100 | 150 | 80 | |||||||
The N-pole offour-poles breaker is sited at the right side of the product has four types:
Type A:Without current trip-lease on N pole which making allthe time,not closing and opening withtheotherthreepoles.
Type B:Without current trip-release on Npole which closing and opening with the other poles.
Type C:With current trip-release which closing and opening with the other three poles.
Type D:With current trip-release which making allthe time not closing and opening with the other three poles.
3.ProtectionCharacteristic
The thermodynamic release of a circuit breaker provides the feature of inverse time-delay,while the magneticrelease is the instantaneous operation as shown on table 2(distribution circuit breaker) and table 3(motor protection circuit breaker).
| Ratedcuraof | |||
| 10 In 63 | 1 | 10ln±20% | |
63| 2 | | ||
100| 2 | 5ln±20% 10ln±20% | | |
YTCM1-250L/3P
| Ratedcurrent of release (A) | Thermodynamicrelease(ambienttemperature | land+40℃ marine+45°℃ | Operating current of magnetic release (A) | ||
| non-triptime(h) | 1.0ln(cold state)1.20ln(heat state)1.50ln(heat state)7.2ln(cold state) trip time (h) | trip time (h) | |||
| 105 In 225 | =2 | 4min | trip time(h) 4s| 12ln±20% | | |
4.AccessoriesofCircuitBreaker
4.1Theexternal accessoriesof thebreaker
·Motor-driven operationdevice 1) Wiring diagram of type CDMelectromagnetic operationdevice(fiting CMM1-63,100,225) see thefollowing drawing (wiring diagramof the external accessories of the breaker in the dotted frame)
YTCM1-400L/3P 丰
区 TSB2(Open) 一 1 SB1(Close) 2
External powersupply
Codedescription:SB,SB,stand for push button.(provided byusers themselves) Number“1”“2”“3” stand fornumber ofwiring terminals.
Voltage rating:AC50/60Hz230V 400V,DC 220V
2)Wiring diagram of type CD motor-driven operation device (fiting CMM1-40o30 800)see belows (wiring diagramof the external accessoriesof the breaker in thedotted frame)
Electromagnetic operationdevice
Code description:SB,SBstand for push button.(provided by users themselves) "X"stands for line connection terminals Voltagerating:AC50/60Hz 230V 400V,DC220V
·Rotary handle operationdevice
Themechanism is used inmoulded case circuit breakerto operate thedraw-out panel.Power distribution panel and supply box outside the panel by turning the handle,and to ensure the door of panel would not be openned when the breaker being on.
The hand-drive mechanism can be equiped with two types of operation,one is { } ^ { \mathfrak { s } } \mathsf { A } ^ { \mathfrak { n } } model square handle,theother is“B”model round handle.
Rotary handleoperationdevice
4.2Release patternandaccessoriescode
SHT:Shunt release; UVR:Under-voltage release; AX:Auxiliary contact;AL:Alarm contact
| Release paterde | Name Type | CMM1-63,100,225 | CMM1-400 | CMM1-630 | CMM1-800 | |||
| 200,300 | Without accessories | 200:magnetic release (only short circuit protection) 300:thermalmagnetic release(bothoverloadand shortcircuit protection) | ||||||
| 208,308 | Alarm contact | AL | AL | AL | AL | |||
| 210,310 | Shunt release | SHT | SHT | SHT | SHT | |||
| 220,320 | Auxiliary contact | AX | AX | AX | AX | |||
| 230,330 | Under-voltagerelease | UVR | UVR | UVR | UVR | |||
| 240,340 | Shunt release Auxiliary contact | SHT AX | SHT | AX | SHT | AX | AX SHT | |
| 250,350 | Shunt release Under-voltage release | SHT UVR | SHT | UVR | SHT | UVR | UVR SHT | |
| 260,360 | Two group of auxiliary contact | AX AX | AX | AX | AX | AX | AX AX | |
| 270,370 | Under-voltagerelease Auxiliary contact | AX UVR | AX UVR | AX | UVR | UVR AX | ||
| 218,318 | Shunt release Alarmcontact | AL SHT | SHT AL | AL | SHT | AL SHT | ||
| 228,328 | Alarmryothact | A | AL AX | AL | AX | AL AX | ||
| 238,338 | Under-voltagerelease Alarmcontact | AL | UVR | AL UVR | AL | UVR | UVR AL | |
| 248,348 | Shuntrelease,Alarmcontact, Auxiliary contact | A | SHT | SHT A | A | SHT | A SHT | |
| 268,368 | Twogroupaof auxiary cntat, | AL | AX | AL AX | A | AX | A AX | |
| 278,378 | A UVR | A UVR | A | UVR | UAR AX | |||
According to user's demands,accessories could lead to direct wire outcoming or line wiring terminalscouldbeadded(pleasemark out incaseofmaking order).
·Under-voltage release Wring diagram of the under-voltage module connected externally(the internal accessories in
thedotted frame)
Ue:AC50/60Hz230V,400V
When the operationvoltage is 3 5 % - 7 0 % of the rated voltage,theunder-voltagerelease should makethebreaker tripcorrectly.
When the operation voltage is 8 5 % ~ 1 1 0 % of the rated voltage,the under-voltage release should makethebreakerclose.
Incase of the operationvoltage less than 3 5 % of the rated voltage,the under-voltage should prevent the breaker fromclosing.
Note:Only the under-voltage release should be energized inadvanced,the breaker could be recrampedand turned-on,otherwise the breakerwillbedamaged.
·Shunt release
Schemeof wiring(the internal accessoriesin thedotted frame) " \mathsf { K } ^ { \prime \prime } is the slow motion switch normal-close contact connect the coil in series in the shunt release. Itturns-onorturns-offvoluntarilyassoonas thebreakeronoroff.
Voltagerating:AC50/60Hz230V 400V,DC110V220V
The shunt release should make the breaker trip reliably when the operation voltage is 7 0 % ~ 1 1 0 % of the rated control voltage.
·Alarm contact
| The position of thebreaker in “offor“on” | B14 O—B11 B12 |
| The position of the breaker in “free trip”alarm | B11 and B12 switch from “lose"to “open"status ofB11and B14 switch from“open”to“lose” |
| Whenthebreakerisin “off” | F14 -F11 F12 F24 F21 | Forthebreakerwith framecurrent 400Aandabove |
| F22 F14 F11 F12 | Forthebreakerwith frame current 225A and below | |
| Whenthebreakerisin “on” | When the breaker is in “off"the contacts switch from“close”to“open” Whenthebreaker isin“off”thecontactsswitch from“open”to“close” | |
5.OutlineandInstallationDimensions
| Type | Outline Dimensions(mm) | Installation | |||||||||||||||||||||||||||||||||||||||||||||||||||||
| Frontpanelconnection | Back panel connection | Plug-inconnection | Dimensions | ||||||||||||||||||||||||||||||||||||||||||||||||||||
| W W1 | L | L1 | L2 | H | H1 | H2 | H3 | H4 | C | D | E | F | G | W2 | W3 | L4 | H5 | H6 | OD | OD1 | L5 | L6 | H7 | H8 | H9 | H10 | J | K | Od1 | M | A | B | d | ||||||||||||||||||||||
| YTCM1-63L | 76 | 50 | 135 | 170 | 117 | 74 | 92 | 20 | 7 | 4 4 | 8528.5 | 48 | 22 | 14 | 100 | 75 | 117 | 44 | 66 | 8 | 8 | 60.7 | 25 | 117 | 3.5 | ||||||||||||||||||||||||||||||
| YTCM1-63M | 76 | 50 | 135 | 170 | 117 | 82 | 98.5 | 28 | 7 | 8528.5 | 48 | 22 | 14 | 100 | 75 | 117 | 44 | 66 | 8 | 8 | 62 | 25 | 117 | 3.5 4.5 | |||||||||||||||||||||||||||||||
| YTCM1-100L | 92 | 60 | 150 | 185 | 132 132 | 68 86 | 86 104 | 24 24 | 7 7 | 8835.550 | 8835.5 | 50 | 22 | 17.5 17.5 | 122 | 90 90 | 129 | 68 | 108 | 26 26 | 16 | 92 | 168 | 50 9216850 | 62 | 74 | 17.5 | 56 | 60 | 6.5 | M8 | 30 | 129 | 1294.5 | |||||||||||||||||||||
| YTCM1-100M YTCM1-100H | 92 | 60 | 150 | 185 185 | 132 | 86 | 104 | 24 | 7 | 88 | 35.5 | 50 | 22 22 | 17.5 | 122 122 | 90 | 129 129 | 68 68 | 108 108 | 26 | 16 16 | 92 | 168 | 50 | 62 62 | 74 74 | 17.556 17.5 | 56 | 60 | 6.5 | M8 M8 | 30 30 | 129 | 4.5 | |||||||||||||||||||||
| YTCM1-225L | 92 | 60 70 | 150 165 | 215 | 144 | 86 | 110 | 24 | 5 | 10231.5 | 50 | 22 | 17 | 142 | 105 | 126 | 66 | 110 | 20 | 20 | 94 | 183 | 5069.584.517.5 | 54 | 60 | 6.5 | 6.5 | M8 | 35 | 126 | 5 | ||||||||||||||||||||||||
| YTCM1-225M107 | 107 | 70 | 165 | 215 | 144 | 103127 | 24 | 5 | 10231.5 | 50 | 22 | 17 | 142 | 105 | 126 | 66 | 110 | 20 | 20 | 94 | 1835069.584.5 | 17.5 | 54 | 70 70 | 6.5 | M8 | 35 | 126 | 5 | ||||||||||||||||||||||||||
| YTCM1-225H107 | 70 | 165 | 215 | 144103 | 127 | 24 | 5 | 4 | 10231.5 | 50 | 22 | 17 | 142105 | 126 | 66 | 110 | 20 | 20 | 94183 | 5069.584.517.5 | 54 | 70 | 6.5M8 | 35 | 126 | 194 7 | 5 | ||||||||||||||||||||||||||||
| YTCM1-400L150 | 96 | 257 | 357 | 224 | 105 110 | 155 160 | 38 43 | 8 8 | 12864.589 134 | 65 | 26198 | 144 | 194 | 60 | 120 | ||||||||||||||||||||||||||||||||||||||||
YTCM1L-120L/4P
1. Application and Description
YTCM1Lseriesearth leakage circuit breakerareone of the newtypeearth leakage breakers which have been developed by the company using international advanced design and manufacturing technology.Suitable fora lineofAC50/6oHz,ratedvoltageup to 40oV,ratedcurrent16A to 630A.and isacted as infrequent changeover of circuit or infrequent starting of motor.The breaker has overload,short-circuitand under-voltage protective function,which can protect the circuitand the power equipmentagainst damage,meanwhile,itcan provide protection to these fire dangers that caused by these long-time existed grounding fault that can not be detected by the over-current protection.
Thisbreakercan be installed vertically(upright) or horizontally(transverse).
Wiring of the breaker can notbe inadverse direction,that means powersupply line must be connectedto terminal1,3and5,and the load lineconnected to terminal2,4and 6.
Therated residual operating current I nand the maximum breaking time canbeadjusted onsiteaccordingtopracticalcondition.
The leakage protection module still can work normally when the phase voltage reduce to 50V. It has the same overall size with the CMM1 series breakers,which make the installation more exchangeable.
The breakersare suitable for isolation,its symbol are:
Thebreakerscomplywith thedemandsof the following standards:
IEC60947-1and GB/T14048.1General
IEC60947-2andGB14048.2Lowvoltagebreakers
IEC60947-4and GB14048.4Contactorsandmotorstarters
IEC60947-5.1andGB14048.5 Electrical equipmentsof electromechanical control circuit
2.MainTechnicalSpecifications
| Type | YTCM1L-100 | YTCM1L-225 | YTCM1L-400 | YTCM1L-630 | |||||||
| Frame current Inm(A) | 100 | 225 | 400 | 630 | |||||||
| Rated current In(A) | (10)16120l25132l 401501631801100 | 100,125,160, 180,200,225 | 225,250,315, 350,400 | 400,500,630 | |||||||
| Polenumber | 3 | 4 | 3 4 | 3 | 4 | 3 | 4 | ||||
| Rated ilnsulation voltage Ui(V) | AC800 | ||||||||||
| Rated working voltage Ue(V) | AC400V | ||||||||||
| Rated impulse with stand voltage Uimp(V) | 8000 | ||||||||||
| Arc-over distance(mm) Breakingcapacitygrade | 50 | ||||||||||
| Limiting short- | M | H | M | H | M | M | |||||
| circuitbreaking capacity lcu (kA) Service short- | AC400V | 50 | 85 | 50 | 50 | 85 | 50 | 65 | 65 | ||
| circuit breaking capacity Ics(kA) Ratedresidual | AC400V Non-delay | 35 | 50 | 35 | 35 | 50 | 35 | 42 | 42 | ||
| operating current type 1△n(mA) Delaytype | 100/300/500 | ||||||||||
| Rated residual non- | 100/300/500 | 300/500/1000 | |||||||||
| operatingcurrentl no(mA) Operation | 1/21△n | ||||||||||
| performance (time) | Electrified | 1500 | 1000 | 1000 | 1000 | ||||||
| Unelecrified | 8500 | 7000 | 4000 | 4000 | |||||||
Note:According to the pole numberof product,it calssifies threeand fourpoles.The neutral pole (N-Pole) of the four-poles products has four types:
TypeA:N-polewithout over-current release unit,it has beenconnectedall the time,not closingand opening with the other three poles.
TypeB:N-pole without over-current release unit,which closing and opening with the other threepoles.
Type C:N-pole fixed with over-current release unit,which closingand openingwith the other threepoles.
TypeD:N-pole fixed with over-current release unit,it hasbeenconnected allthe time,not closing and opening with the other three poles.
1.Thelimiting breaking and arc-over distance includes horizontal and vertical installation. 2.If the three-pole breaker of this series is connected with three phase load,the load can not haveneutral line,otherwise the breakerwill have faultaction. 3.If the three-pole breakerof this series isconnected with single phase load,the phase line willbe connected to the leftpole,and the neutral line isconnected to the right pole,themiddle poleisblanket
3.ProtectionCharacteristic
Thethermal releaseof the breaker hasagain-time-limit property;theelectromagnetic release is inst. Operation, its property see table 2(for distribution),table 3 (motor protection).
| Ratedcurrentof release(A) | Thermal release (ambienttemperature+40℃) | Electromagneticrelease trippingcurrent(A) | |
| 1.05ln(cold state) non-trip time (h) | 1.03ln(hot state) trip time (h) | ||
| 10≤In≤63 | 1 | 1 | 10ln 20% |
| 63≤In≤125 | 2 | 2 | |
| 125≤In≤630 | 2 | 2 | 5ln 20% 10In 20% |
| Rotrelcarent | Thermal release (ambient temperature+40℃) | ||||
| (h) | 1.50lngthermal | ||||
| 10≤In≤400 | 2 | 2 | 8min | 6s| 12ln±20% | |
4.Residual CurrentOperatingTimeofEarthLeakage CircuitBreaker
4.1Non-delay type operationcharacteristicssee table 4(l \Delta n <= 3 0 m A should be Nondelaytype)
| Ratedcurrent | I△n | 2l△n | 5△na | 10l△n | |
| Non-delay type | Max.breaking time(s) | 0.3 | 0.15 | 0.04 | 0.04 |
4.2Delay type operationcharacteristicssee table5
Limiting non-driven time of delay type earth leakage circuit breaker according to 2ln, operationcharacteristicsseetable5
Back panel connection
| Delay time (s) | Max.breaking time(s)atI△n | Limiting non-driventime (s)at2l△n | Max. breaking time(s) | Max.breaking | Max.breaking time(s)at5l△ntime(s)at10l△n |
| 0.1 | 0.4 | 0.06 | 0.2 | 0.15 | 0.15 |
| 0.2 | 0.5 | 0.06 | 0.2 | 0.15 | 0.15 |
| 0.3 | 0.6 | 0.1 | 0.4 | 0.3 | : |
| 0.4 | 0.7 | 0.2 | 0.5 | 0.4 | · |
| 0.5 | 0.8 | 0.3 | 0.6 | 0.5 | : |
| 0.6 | 0.9 | 0.4 | 0.7 | 0.6 | : |
| 0.7 | 1.0 | 0.5 | 0.8 | 0.7 | : |
Electromagneticoperationdevice
5.AccessoriesofCircuitBreaker
5.1The external accessoriesofthe breaker
·Motor-drivenoperationdevice 1) Wiring diagramof type CDMelectromagnetic operation device(fiting CMM1L-100,225) see the following drawing (wiring diagramof the external accessories of the breaker in the dotted frame)
2)Wiring diagramof type CD motor-driven operation device (fiting CMM1L-40e30) see belows (wiring diagramof theexternalaccessoriesof thebreaker inthedotted frame) Code description:SB1 \mathsf { s B } _ { 2 } stand for push button.(provided by users themselves) Number“1”“2”“3"stand for number of wiring terminals. Voltagerating:AC50Hz230V400V,DC220V
Code description:SB \mathsf { s B } _ { 2 } stand for push button. (provided by users themselves) "X"stands for line connection terminals Voltage rating:AC50Hz230V400V;DC220V
·Rotaryhandleoperationdevice
The mechanism is used in moulded case circuit breaker to operate the draw-out panel.Power distribution panel and supply box outside the panel by turning the handle,and to ensure the door of panel would not be openned when the breaker being on.
The hand-drive mechanism can be equiped with two types of operation one is“A"model square handle,theother is“B"model round handle.
5.2TheInternalAccessoriesoftheBreaker
5.2.1Release patternandaccessoriescode see following table
SHT:Shunt release; UVR:Under-voltage release; AX:Auxiliary contact;AL: Alarm contact
| Release patern | Name Type | CMM1L-100,225 | CMM1L-400 | CMM1L-630 | |
| 200,300 | Without accessories | 200:Magnetic release (only short circuit protection) 300:Thermal magnetic release(both overload and short circuit protection) | |||
| 208,308 | Alarmcontact | AL | AL | AL | |
| 210,310 | Shuntrelease | SHT | SHT | SHT | |
| 220,320 | Auxiliary contact | AX | AX | AX | |
| 230,330 | Under-voltagerelease | UVR | UVR | UVR | |
| 228,328 | Auxiliary contact, Alarmcontact | AL AX | AL AX | AL AX | |
Auxiliary contact
5.2.2The technical parameterand functions of the accessories
| Accessory | Ratedoperatingvoltage(V) | |||
| AC50/60Hz | DC | |||
| Shunt releaseUs | 220(230) | 380(400) | 110 | 220 |
| Under-voltage release Us | 220(230) | 380(400) | ||
Auxiliary contactandAlarmcontact:Auxiliarycontact isassomeasAlarmcontact,the technicalparameterseefollowingtable
| Ratedthermal current Ith (A) | Ratedoperatingcurrentle(A) | Suited Frame Inm(A) | |
| AC380V | DC220V | ||
| 3 | 0.3 | 0.15 | 100,225 |
| 3 | 0.4 | 0.15 | 400,630 |
| Accessories | Function | Wiringconnectiondiagram | ||||
| Alarm contact | Indicatecircuit breakerattripping | |||||
| Auxiliary contact | Indicatecircuitbreakerat openingorclosing | B1 | -F11 The position of breakerat opening | |||
| Shunt release | The shunt release should make the breaker trip reliablywhen the operatiopnvoltage is70%-110%of rated control voltage | The micro switch will cut by itself when breaker open | ||||
| Under-voltage release | When Ue is35%-70% of the rated control voltage,the under voltage releaseshouldmakethebreakertripcorrectly WeUudtotrta Incaseof Ue less than35%of the rated control voltageshould prevent thebreaker fromclosing | |||||
6.OutlineandInstallationDimensions
| Type | Outlinedimensions | Installation | ||||||||||||||||||||||
| Front panel connection | Bankpanel | Plug-in connection | dimensions | |||||||||||||||||||||
| W | L | H | W1 | L1 | L2 | H1 | H2 | L3 | H3 | D | L4 | L5 | H4 | H5 | H6 | C D | D1 | A | B | d | ||||
| YTCM1L-100M,H/3P | 92 | 150 | 92 | 60 | 200 | 200 | 132 | 110 | 28.5 | 90 | 93 | 168 | 92 | 50 | 64 | 76 | 60 | 56 | 6.5 | 30 | 129 | 4.5 | ||
| YTCM1L-100M,H/4P | 122 | 150 | 92 | 90 | 200 | 200 | 132 | 104 | 28.5 | 90 | 93 | 168 | 92 | 50 | 64 | 76 | 60 | 56 | 6.5 | 30 | 129 | 4.5 | ||
| YTCM1L-225M,H/3P | 107 | 165 | 90 | 70 | 265 | 265 | 144 | 110 | 24 | 93 | 100 | 183 | 94 | 50 | 71.5 | 86.5 | 90 | 54 | 6.5 | 35 | 126 | 5.5 | ||
| YTCM1L-225M,H/4P | 142 | 165 | 103 | 105 | 265 | 265 | 144 | 127 | 24 | 93 | 100 | 183 | 94 | 50 | 710.5 | 86.5 | 70 | 54 | 6.5 | 35 | 126 | 5.5 | ||
| YTCM1L-400M,H/3P | 150 | 257 | 106.5 | 96 | 441 | 441 | 224 | 146.5 | 38 | 164 | 108.5 | 279 | · | 60 | 83.5 | 106.5 | 105 | 129 | 8.5 | 44 | 194 | 7 | ||
| YTCM1L-400M,H/4P | 198 | 257 | 106.5 | 144 | 441 | 441 | 224 | 146.5 | 38 | 164 | 108.5 | 279 | 60 | 83.5 | 106.5 | 70 | 129 | 8.5 | 44 194 | 7 | ||||
| YTCM1L-630M,H/3P | 210 | 280 | 115.5 | 145 | 480 | 480 | 243 | 155 | 45.3 | 158 | 84 | 296 | 61 | 97 | 148 | 140143 | 10 | 70 243 | 7 | |||||
| YTCM1L-630M,H/4P | 280 | 280 | 115.5 | 210 | 480 | 480 | 243 | 155 | 45.5 | 158 | 84 | 296 | 1 | 61 | 97 | 148 | 210143 | 10 | 70 243 | 7 | ||||
TYW1-2000
1. Application
TYW1series intelligentcircuit breaker (hereinafter referredtoas breaker) is suitable for the circuit ofAC 50/60Hz with rated voltage 400V,690Vand rated current up to 6300A.Itis mainly usedtodistribute electricenergyand protect circuitand powersupplyequipmentfrom overload, under-voltage short-circuit,and single-phase earthing.With intelligent and selective protection functions,the breaker can improve the reliabilityof power supply,and avoid unnecessary power failure.The breakerisapplicable for powerstations,factories,mines(for 69oV)and modern high-building,especially for the distribution system of intelligent building.
The breaker conforms to IEC6o947-2.The whole series have past CCC certification and CE certification.
TYW1-6300
2.EnvironmentConditionsforOperation
Temperature condition: - 5 ^ { \circ } { \mathsf { C } } { ~ } + 4 0 ^ { \circ } { \mathsf { C } } , theaveragevaluewithin 24h not exceed ^ { + 3 5 } (204 Elevation:altitudeof installationplaceshallnotexceed 2 0 0 0 { m } #
Atmosphere condition:relative humidityat + 4 0 shall not exceed 5 0 % Higher humidityis permissibleat lower temperature condition.When the higher monthly average relative humidity is 9 0 % inthehumiddestmonth,the lowestmonthlyaverage temperatureof thismonth 1 5 + 2 5 And consider the influence of dew on product surface due to temperature changes.
Pollution grade: gradelll.
The breaker should be installd according to the requirement on the instruction manual: the vertical inclinationdegreeshall not exceed 5 ^ { \circ }
3.Specification
| Type | TYW1-2000 | TYW1-3200 | TYW1-4000 | TYW1-6300 | |
| Frame rated current Inm (A) | 2000 | 3200 | 4000 | 6300 | |
| Number of poles | 3,4 | 3,4 | 3,4 | 3.4 | |
| Rated current In (A) | 630,800,1000, 1250,1600,2000 | 2000,2500, 3200 | 2000,2500, 3200,4000 | 4000,5000, 6300 | |
| Icu (kA) | 400V | 80 | 100 | 100 | 120 |
| 690V | 50 | 65 | 65 | 80 | |
| lcs = lcw (kA) | 400V | 50 | 80 | 80 | 100 |
| 690V | 40 | 50 | 50 | 65 | |
| Rated current at N-pole In (A) | 50%ln,100%ln | ||||
| Inherentmaking breaking time | 23-32ms | ||||
| Operational performance (operations) | Electric life | 500 | |||
| Mechanical life | Maintenance-free2500 Maintenance 10000 | ||||
| Mounting mode | Fixed withdrawable | ||||
| Arcing distance(mm) | 0 | ||||
| Intelligentcontroller | Standard type(M) telecommunication type (H) | ||||
4.IntelligentController
Intelligent controllerisoneof thecorecomponentsof thecircuitbreaker
4.1propertiesof the intelligent controller
a.Protective function of over-load long time-delayand inverse time limit,short time-delayand inverse time limit,short time-delay definite time limit instantaneous operation protection; b.Single-phaseearthing failure protection; c.Display of setting current Irand operational current; d.Ampere meter; e. Over-load alarm; f.Short-circuitalarm g.Testing of operational properties
Note:The breakerswith telecommunication portareavailable torealizeremotecontrol to breaker throughmastercomputer.
4.2Protection performancesofover-currentrelease
a.Irand its inaccuracy of thecontroller
| Inm(A) | Longtime-delay | Shorttime-delay | Instantaneous | Earthingfailure | ||||
| Ir1 | Error | Ir2 | Error | Ir3 | Error | Ir4 | Error | |
| 2000 | (0.4~1)ln | ±10% | (0.4~15)ln | ±10% | 1.0ln~15kA | ±15% | Inm 4000A(0.2-0.8) In (Max.1200A.Min.200A) Inm 6300A(0.2-1.0) In | 10% |
Note:1.When the breaker could realize over-load with long timedelay.short-circuit withshorttime-delay andshort-circuit instantaneous protections,the setingratings cannotbeover-lapped,and Ir1<lr2<Ir3 2.When the frame is 320oA andabove,the setting ratings range from1.01ln to 75kA.
| 1.05 Ir1 | 1.3 Ir1 | 1.5Ir | 2.0Ir1 |
| >2h non-tripping | 15s,30s,60s,120s,240s,480s | 8.4s,16.9s,33.7s,67.5s,135s,70s |
c.Characteristicsof short time-delayprotection.
For low over-current,inverse time-limit protection could be realized; when the over-current is > 8 \mathsf { I r } 1 ,it will automaticallychange to bedefinite time-limit protection properties.
Referto table below for time-limit properties.
| Setting delay time (s) | Returnable time (s) |
| 0.1,0.2,0.3,0.4 | 0.06,0.14,0.23,0.35 |
5.StandardComposition
To facilitate your ordering and utilization,the CMW1 intelligent with basic electric accessories as follows.
| Standardcompositionofthebreaker | Fixedtype | Withdrawabletype |
| Body | ||
| Drawerbase | ||
| Intelligentcontroller | ||
| Electricmotor | ||
| Closingelectro-magnet | ||
| Shuntrelease | ||
| Under-voltage | ||
| Auxiliary contact | ||
| Doorframe |
6.Accessories
6.1Shunt release
a.Shunt release is forremote breaking of circuit breaker soas toenhance security of the operator;
b.Ratingsofshunt release
| Ratedoperationalvoltage(V) | AC220V | AC380V | DC110V | DC220V |
| Operational voltagerange | (70%~110%) Ue | |||
| Powerconsumption | 24VA | 24VA | 40W | |
6.2Under-voltage release
a.It isan optional accessory; b.Mainly used to protectionapparatus from damage due to lowering of the operational voltage toacertainvalue; c.Two types of release areavailable: instantaneous releaseand time-delay release; d.Forbreakers appended with the release,it should be electrified continuously; e.Ratingsofunder-voltagerelease. f.Operation properties of under-voltage release
| Ratedoperational voltage (V) | AC220V | AC380V | DC110V | DC220V | |
| Operationalvoltagerange | (35%~110%) Us | ||||
| Power consumption | 24VA | 24VA | 40W | ||
| Category | Under-voltagetime-delay release | Under-voltageinstantaneous release | |||
| Operation timeof therelease | Time-delay:1s,s,5s | Instantaneous | |||
| Operational voltage | 35%Us~70%Us | Break thebreaker | Breakthebreaker | ||
| 35%Us | Cannotmake the breaker | Cannotmake thebreaker | |||
| of the release | 85% Us~110% Us | Reliablymakethebreaker | Reliablymakethebreaker | ||
| Within1/2delay time,voltageof power supply recovers to 85% Us | Cannot trip the breaker | ||||
6.3Closing electro-magnet
a.Themagent is for remote making of circuit breaker soas to enhancesecurity of the operator.
b.Themangentcould notbeelectrified fora long time.
c.Ratings of the magnet.
| Ratedoperationalvoltage(V) | AC220V | AC380V | DC110V | DC220V |
| Operational voltagerange | (85%~110%)Us | |||
| Powerconsumption | 40VA | 40VA | 40W |
6.4Auxiliary contact
a.Conventional heating current of auxiliary contact:6A b.Auxiliary contacts: 4 N O + 4 N C ,3NO+NC,5NO+5NC(customization)
TYW1-4000,5000 Drawer type
TYW1-6300 Drawer type(3-pole)
DrawerTypeStructureExplosion
TYQ2-100/4P
1. Application
HATS seriesautomatic transfer switch is one new ATS of our company developed by the microcomputercontroltechnology.ThisseriesATS issetled CMM2circuitbreakeras theexecutive element,and along with the mechanotrons,the new control mechanism with electromechanicaldouble interlock,which isespeciallyapplied inthe important places notallowed power off.Tomeet actual demand,three different operation methodsare available such asautomatic entryautomatic reset,automatic entry nonautomatic reset and commutative standby.
The device conforms to IEC60947-6-1.The whole series have past CCC certification.
2.Environmentconditionsforoperation
Temperaturecondition: \boldsymbol { * } 5 ^ { \circ } \mathsf { C } ~ + 5 5 ^ { \circ } \mathsf { C } ;relativehumidity < 9 5 % at55 Elevation:altitude of installationplaceshall not exceed 2000m. Pollution grade: grade Ill.
TYQ2-100/4P-D1
3.Type and meaning
Standard product Non-standard product
HATS-口/口CB一□ LX: with fire protection linkage function ┌R:automaticentryautomaticreset Operation methods:S:automatic entry non automatic reset -l: commutative standby CB type ATS,with short circuit,overload protection Switching poles:3P,4P Current Grade:100,160,250,400,630 Controllermodel:A type,B type,Nocontrollerno mark SAIAOPOWERTECHNOLOGYCO.,LTD.
Note:Tothe nonstandard products,the specific type offire protection signal should be noted.Without note, thedefaultbe considered DC24V.
4.Mainfeatures
Threeavailableoperationmethods
1.Automatically entryandautomaticallyreset
2.Automaticallyentryandnonautomaticallyreset
3.Commutative standby
Threesteady operating positions
1.The grid power supply is making,the standby power supply is breaking. 2.The grid power supply is breaking,the standby power supply is making. 3.The grid power supply is breaking,the standby power supply is breaking.
Compactsize,single structure,beautiful outlook,12.5\~63oAavailable,convenient operation and long operating life,3P,4Pcanbesupplied.
The transfer is drived bysingle motor,single structure,reliable transfer,no noiseand small wallop.
The device is with electromechanical interlock protection,which can ensure the two power suppliesworking normally,no disturbance.
The device can be along with load automatic transfer,on urgent situation,it can be transferredbyhandle.
Advantagescomparativetootherproducts:
1.The breaking capacityof the control protecting fuse is 5okA,which increases the distributionsafety.
2.There is interlock between manual and automatic operation,this can avoid the manual operationontheautomaticoperation. 3.When the executive handle of circuit breaker is broken,the contact is felted or the load is in problem(overload,shortcircuit),theATSdonottransfer,theiscalledtherealelectromechanical interlock. 4.The wrong wire connection indication can be supplied.When the phase wire and zero wire isconnected wrong,the sound-photo device will alarm,it ensures the reliability.
5.FunctionofcontrollerinHATSautomatictransferswitch
| ?Standard | Comonpwwersupplyidicaionand | Test | Comet | Tutmonitorsandbypowersupply and | Tumonitorommonpowersupplyand | Automatic operation | |||||||||||||||||||||||||
| configuration + | 8 | + | □ | lackingCeck phaing | + | + | |||||||||||||||||||||||||
| □pelective function | + | + | |||||||||||||||||||||||||||||
Note:
1.If operational voltage is the same as power voltage,the common power supply and standby power supplycansupplypowerdirectly.If not,itmust use equivalent isolation transformer.
2.Under thesituationof handle operation,if thecontrol of electrical manipulatingdevice isopen,automaticcontrollingfunctionwillbeinvalid.
3.Onconditions both common power supplyand standby power supplyare normal,if commonpower supply is malfunctionand automaticaly transfer to standby power supply (transfer time delayadjustable), when thecommonpower supplyreturns tonormal,it willautomatically return(return timedelayadjustable). 4.Under the situation both common power supply and standby power supplyare normal and common powersupplyisworking,if commonpowersupplyismalfunctionand automaticallytransfer tostandby powersupply.Controllerwillstoptransferring.Even ifcommonpowersupplyreturn tonormal,switchwillnot return.Please pressreset pushbutton,controller returnsto normal.
5.Underthe situation both common powersupplyand standbypower supplyare normal,togetthrough electricity(orreset),thecommonpower supplywillwork prior.If the working power has some malfunction duringoperationand automaticall transfer to anotherpowersupply(type Bswitching transfer time delay adjustable),both powersupply willhave the same priority and willbe standby powersupply of each other.
6.Outlineandinstallationdimension
| Type | L(3P/4Pi(ps/4P) | L1(3P/4P)WP/P | ||||
| HATSA-100 | 430/500 | 200 | 140 | 400/470 | 155 | 6.5 |
| HATSA-160 | 430/500 | 200 | 140 | 400/470 | 155 | 6.5 |
| HATSA-250 | 430/500 | 200 | 140 | 400/470 | 155 | 6.5 |
| HATSB-100 | 500/570 | 200 | 140 | 470/540 | 170 | 6.5 |
| HATSB-160 | 500/570 | 200 | 140 | 470/540 | 170 | 6.5 |
| HATSB-250 | 500/570 | 200 | 140 | 470/540 | 170 | 6.5 |
| HATSB-400 | 620/710 | 275 | 190 | 590/680 | 245 | 9 |
| HATSB-630 | 620/710 | 275 | 190 | 590/680 | 245 | 9 |
TYQ5-100/4P
1. Application
TYQ5 Series automatic transfer switch (transfer switch) is developed successfully with the helpof themostadvancedATS technology inthe world.Thiskind of transferswitchand intelligent display mated with itare mainly applied in the occasions required uninterrupted power supplylike building,postsand telecommunications,mine industry,shippingand military industry. Under the necessary trend of urban power service increasing,itcanmeet the higher requirementsof the reliablepower service.This product has many features like reliable performance, small volume and simple operating etc.
2.Mainfunction
With safe and reliable interlocking function,when the breaker is under closing state,the breaker cannot be glugged inor drawn out,you must open the breaker first to plug in or pull out. With functionof reliable making and breaking main circuit and secondary circuit,besides,the device possesses self-locking function.
Whenyou draw out the breaker,the device hassafe insulating isolation (yourfinger will not touch with the charged parts).
The breaker can be mounted with various rotating manual operating mechanism and motor operating mechanism.
TYQ5-250/4P
3.Specification
| Type | QCQ5 | |||||||||||||||||
| Type TYQ5(Three-step type) | TYQ5-100 | TYQ5-250 | TYQ5-400 | TYQ5-630 QCQ5-800 | ||||||||||||||
| Ratedvoltage | AC690VDC125V | |||||||||||||||||
| Rated current | 100A | 250A 400A | 630A | 800A | ||||||||||||||
| Number of cutting in | Double cut-in | |||||||||||||||||
| Connecting *mode | Infront of panel and at back of panel (Non standard *product) | |||||||||||||||||
| Operat- ing | DC110V (A) | 3 | 3 | 4 | 3 | 4 4 | 5 | 5 | 5 | 7 | 6 | 6 | 6 | |||||
| AC100V/110V (A) | 3 | 3 | 4 2 | 3 2 | 5 | 5 | 5 | 7 | 6 | 6 | 6 | |||||||
| current Trip | AC200V/220V (A) | 1.5 1.5 1.5 | 2.5 2.5 | 2.53.5 | 3 | 3 | 3 | |||||||||||
| DC110V | 1A | 1.5A | 2A | |||||||||||||||
| AC100V/110V | 1A | 1.5A | 2A | |||||||||||||||
| current | 0.5A | 0.7A | 1A | |||||||||||||||
| Perfor- mance | Short-time withstanding current | 5kA | 10kA | 12kA | 15kA | |||||||||||||
| Ratedconditionalshort- circuit current | 12.5kA | 25kA | 30kA | 37.5kA | ||||||||||||||
| Makingand breaking | AC-33B(10lemaking8leopening)cos?0.35 | |||||||||||||||||
| capacity A power | Cut in | 55ms | 60ms | DC-33B1.1lemaking1.1le opening L/R=1ms | ||||||||||||||
| Changeover side B power | Cut off | 55ms 20ms | 20ms | 25ms | 100ms 30ms | |||||||||||||
| time side | Cut in | 80ms | 80ms | 90ms | 135ms | |||||||||||||
| Service life | Cut off | 20ms | 20ms | 25ms | 30ms | |||||||||||||
| Operationcircle time | With 2500 times of electriclife with10oo0 times(120times/hour)of mechanicalife 120time/hour | |||||||||||||||||
| Auxiliaryswitch | Asource1CB source1C switchcapacityAC100V5AAC200V2.5ADC100V0.5A | |||||||||||||||||
| Accessory | Protective cover breakthoughabsorbermanual handle | |||||||||||||||||
| Type | TYQ5 | ||||||||||||||||
| Tyep TYQ5 (Three-step type) | TYQ5-1000 TYQ5-1250 | TYQ5-2000 TYQ5-3150 TYQ5-4000 | |||||||||||||||
| Rated voltage | AC690VDC125V | TYQ5-1600 | AC690V | ||||||||||||||
| Rated current | 1000A | 1250A | 1600A | 2000A 3150A | 4000A | ||||||||||||
| Numberof cutting in | Doublecut-in | ||||||||||||||||
| Connecting*mode | At the back of panel in the front of panel At theback of panel | ||||||||||||||||
| Number of pole | 2P | 3P | 4P | 2P | 3P | 4P 2P | 3P | 4P | 2P | 3P | 4P | 2P | 3P 4P | 3P | |||
| Weight(kg) | 30(40)39(54) | 49(64) | 31(45) | 40(56)51(66) | 36(50) | 47(62) | 59(74) | 95 | 115135 | 110150190 | 207 | ||||||
| Operat- DC110V (A) AC100V/110V (A) | 6 | 6 | 8 6 | 6 | 8 | 7 | 8 | 9 | 8 10 | 12 | 10 | 12 | 14 | 16 | |||
| ing | 6 | 6 | 8 6 | 6 | 8 | 7 | 8 | 9 | 8 10 | 12 10 | 12 | 14 | 16 | ||||
| current | AC200V/220V (A) | 3 | 3 | 4 | 3 | 3 | 4 | 3.5 4 | 4.5 | 4 | 5 | 6 | 7 8 | 7 | 8 | ||
| DC110V | 2A | 4A | |||||||||||||||
| Trip AC100V/110V | |||||||||||||||||
| current | AC200V/220V | 2A | 4A | 1A | |||||||||||||
| Short-time withstanding current | 1A 22kA | 25kA | 35kA | 50kA | 50kA | ||||||||||||
| Ratedconditional short-circuit current Making and breaking | 50kA | 55kA | 55kA | 80kA | 100kA | ||||||||||||
| capacity | AC-33B(10lemaking8leopening) cos?0.35 | AC2(lemaking le opening) cos?0.65 | |||||||||||||||
| Perfor- mance Changeover | A powerCut in | DC-33B1.1lemaking1.1leopeningL/R=1ms 115ms | 115ms | 180ms 140ms | 200ms(190) | ||||||||||||
| time | side B powerCut in | Cut off 25ms | 25ms | 25ms | 190ms | 30ms | 30ms(30) 220ms(240) | ||||||||||
| side Cut off | 145ms | 25ms | 150ms | 220ms | 25ms | 30ms | 30ms(30) | ||||||||||
| Service life | 25ms | ||||||||||||||||
| Operationcircle time | 120 times/hour | DC100V0.5A | 30times/hour | ||||||||||||||
| Auxiliaryswitch Accessory | Asource1CB source1C switchcapacityAC100V5A AC200V2.5A | ||||||||||||||||
| Protective coverbreakthoughabsorbermanual handle | |||||||||||||||||
| Type | TYQ5 | |||||||||||
| TyepTYQ5 (Two-step type) | TYQ5-125 | TYQ5-250 | TYQ5-400 | |||||||||
| Rated voltage | AC690VDC125V | |||||||||||
| Ratedcurrent | 40A,63A,100A,125A | 160A,200A,225A,250A | 350A,400A | |||||||||
| Number of cutting in | Double cut-in | |||||||||||
| Connecting*mode | In front of panel and atback of panel | |||||||||||
| Operating current | DC110Y(V(A) | 33 | 33 44 | 33 | 44 | 55 | 55 | 55 | 77 | |||
| AC200V/220V (A) | 1.5 | 1.5 | 2 | 1.5 | 2 | 2.5 | 2.5 2.5 | 3.5 | ||||
| Trip current | DC110V | 1A | 1.5A | |||||||||
| AC100V/110V | 1A | 1.5A | ||||||||||
| AC200V/220V Short-timewithstanding current | 0.5A | 0.7A | ||||||||||
| Rated conditionalshort-circuitcurrent | 5kA 10kA | 12kA 30kA | ||||||||||
| Perfor- mance | Makingandbreaking capacity | 12.5kA 25kA AC-33B(10lemaking 8le opening) cos?0.35DC-33B1.1lemaking1.1leopeningL/R=1ms | ||||||||||
| Changeover time B power | Apower side | Cut in | 55ms | 55ms | 60ms | |||||||
| Cutoff | 20ms | 20ms | 25ms | |||||||||
| Cut in | 80ms | 80ms | 90ms | |||||||||
| side | Cutoff | 20ms | 20ms | 25ms | ||||||||
| Service life Operationcircle time | ||||||||||||
| 120 times/hour | ||||||||||||
| Auxiliary switch | Asource1CB source1C switchcapacityAC100V5AAC200V2.5ADC100V0.5A | |||||||||||
| Accessory | ||||||||||||
4.OutlineandInstallationDimensions
TYQ5-632P
TYQ5-634P
1.Application
TYQ5-63seriesautomatic transferswitch issuitable for the dual power supplyofAC 50/60Hz,rated voltage AC85-280V,up to 63A.Itworks from one main power to another reserved powerto protect powersupplied normally.Its function depends on its configuration of the controller.
2.Mainspecification
| Type | TYQ5-A | TYQ5-B | TYQ5-C | TYQ5-D |
| Poles | 3,4 | |||
| Current | 6A,10A,16A,20A,25A,32A,40A,50A,63A | |||
| Operating voltage | AC150-265V50/60HZ | |||
| range Installation | All in 1 | |||
| Operating method | Automatic,Manual | |||
| Motor control | No | 1×5Arelay | No | 1×5Arelay |
| Firengie service | No | Passivecontact input,1Nepasaive contact | No | Passivecontact input,1Npasive contact |
| Conversiondelaytime | 0.2s fixed | 0.2-30s adjustable | 0.2s fixed | 0.2-30s adjustable |
| Returningdelay time | 0.2s fixed | 0.2-30s adjustable | 0.2sfixed | 0.2-30sadjustable |
| Circuit inspection | A,N | A,N | A,B,C,N | A,B,C,N |
| Under-voltage test | Yes | |||
| Phase release | A,N | A,N | A,B,C,N | A,B,C,N |
3.Outline and Mounting Dimension (mm)
Note:Thedatameets3Pole.A,B,C,D measureare thesame.
TYQ5-100/4P
1.ProductOutline
TYQ5automatic change-over switch(ATSE) integrates switch and logic control,thus it is notnecessary to provideexternal controller.This trulyelectromechanically integratedautomatic change-over switch has the following functions such as voltage detection,frequency detection,communication interface,electricalandmechanical interlocking etc.,so,automatic control,electrical remote control and emergencymanual control can be performed.
The operation is carried out through the logic control board,which gives various commands to control the motor and gear-box.the motor drives the accelerator which can take switchspring poweraccmulating and instantaneous release,swiftly turns makingand breaking the circuit or makes circuit switching,the visibleoperationstatus can helpyou to performsafe separation,increasing extremely the various electrical and mechanical performance.
Which the shell of switch SGLD is made of different materials:the control section is made of metal,but theswitching section is made of glass-fibre unsaturated polyester resin,having stronger dielectric propertyand protective capabilityas wellas safe operation performance.
TYQ5-250/4P
This kind of switch is suitable for the automatic changeover of the main power source and the secondary power source of the power supply system of the automatic change-over and safeseparationofthe2setsofload-equipment.
This kind of switch hasa beautiful, novel and simple structure,asmall volume but complete functions,being the best choice among congeneric of products.
SGLDseries had beenalreadypassed thedetectionof EMC.
2.MainTechnicalParameters
| Conventionalthermalcurrent Ith(A) | 160A | |||||||||
| 20A | 40A | 100A 63A | 80A | 100A | 125A | 160A | ||||
| Rated current In(A) Rated impulsewithstandvoltage Ui(V) | 500 | 500 | 500 | 500 | 500 | 500 | 500 | |||
| Dielectric strength(V) | 5000 | 5000 | 5000 | 5000 | 5000 | 5000 | 5000 | |||
| Ratedsurge-resistantvoltage Uimp kV(installedcategory IV) | 8 | 8 | 8 | 8 | 8 | 8 | 8 | |||
| 380V Ratedworkingcurrent | AC-31 | 20 | 40 | 63 | 80 | 100 | 125 | 160 | ||
| AC-33 | 20 | 32 | 40 | 63 | 80 | 125 | 160 | |||
| AC-35 | 20 | 40 | 63 | 80 | 100 | 125 | 160 | |||
| 220V | DC-31 | 20 | 40 | 63 | 80 | 100 | 125 | 160 | ||
| DC-33 | 20 | 32 | 40 | 63 | 80 | 100 | 125 | |||
| DC-35 | 20 | 40 | 63 | 80 | 100 | 125 | 160 | |||
| MoterpowerP(380V) kW | 10 | 20 | 25 | 30 | 32 | 63 | 80 | |||
| Rated short-time withstand current(kA Rms)0.1S/1.0S | 9/5 | 9/5 | 9/5 | 9/5 | 9/5 | 20/10 | 20/10 | |||
| Ratedbreakingcapbility(ARms)AC33380V | 160 | 320 | 500 | 640 | 800 | 1000 | 1000 | |||
| Ratedmakingcapability(ARms)AC33380V | 200 | 400 | 630 | 800 | 1000 | 1250 | 1250 | |||
| Rated short-current making capability Icm(kA peak value) | 8 | 8 | 10 | 10 | 10 | 12 | 12 | |||
| Mechanical durability(number of cyclic operation) | 8000 | 8000 | 8000 | 5000 | ||||||
| Electric durability | COS00.65 AC33 | 1500 | 1500 | 8000 1500 | 8000 1500 | 1500 | 1000 | 5000 1000 | ||
| Change-oner time | I-0-ll or Il-0-1(s) | 0.5 | 0.5 | 0.5 | 0.5 | 0.5 | 1.0 | 1.0 | ||
| Power consumption | I-0 or Il-0(s) | 0.3 | 0.3 | 0.3 | 0.3 | 0.3 | 0.6 | 0.6 | ||
| ofelectricalcontrol | 24V(DC)(w) | 50 | 50 | 50 | 50 | 50 | 75 | 75 | ||
| 220V(AC)(w) | 50 | 50 | 50 | 50 | 50 | 75 | 75 | |||
| Moment of operation(Nm) | 15 | 15 | 15 | 15 | 15 | 22 | 22 | |||
| Weight(kg) | 3Poles | 4.2 | 4.3 | 4.4 | 4.5 | 8.2 | 8.2 8.7 | |||
| 4Poles | 4.5 8.7 | |||||||||
1.Application
TheTY-llevel surge protector has high lightning discharge capacity,noleakage current,no free wheeling current,modularinstallation,high safetyfactor,andlongservicelife.Itadoptsa 3 5mm standard guiderailinstallation methodand isinstalledin the building's main distribution cabinet(box) and outdoordistribution cabinet(box).
2.Install
Theproductis installedatthejunctionofLPZOAorLPZOBandLPZ1area,orat themaindistribution box(cabinet) where the power supply is introduced,using 3 5mm standard guide railsand connecting wiresusing 6 { - } 3 5mm ^ { 2 } multistrandedcopperflexiblewires.
The groundingwire should usea dual colorwire ofat least 1 0mm 2 ,withatotal lengthcontrolledwith in0.5m.Inorderto preventthe failureofsurge protectors fromaffecting the normal operation of the powergrid,the protectors connected to the Lline should be connected in series withamatching SCB backup protector orfuse/circuit breaker for short circuit protectionafter SPD breakdown.
The altitude does not exceed 20oo meters,and there is no impact vibration or shaking in the area. The relative humidity shall not exceed 9 0 % ( 2 5 ^ { \circ } \mathsf { C } )
All lightning protectiondevicesmustbe effectively grounded.
| M号delspecifiations | TY-112.5 | TY-115 | TY-125 | TY-150 |
| 最大imu续工作tin压Uc(vVArking voltage Uc(VAC) | 275、385V、420V | |||
| 压保护水平cUponevel Up(kv) | 2.5 | 2.5 | 2.5 | 2.5 |
| 最a大放u流Cimp(10u/350utimp(10/350μs)(kA) | 12.5kA | 15kA | 25kA | 50kA |
| 25 | 30 | 50 | 100 | |
| R应时nsetimens | ||||
| P护等tion grade | IP20 | |||
| Antemperature | -40°℃-85℃ | |||
| 测试级别 Test level | 一级保护、阻燃尼龙 First level protection,flame retardant nylon | |||
| 遥信功能 Remote signaling function | 可另配货 Can bedispensed separately | |||
| 备注 Notes | 其他最大持续工作电压Uc可定做 Other maximum continuous working voltage Uc can be customized | |||
4. Appearance and installation wiring dimensions (mm)