PRODUCTCATALOGUESUZHOU DELFINOENVIRONMENTAL TECHNOLOGYCO., LTDwww.daruifuno.com
+86-18013144571
info@daruifuno.com
Room 301, Building 3, No. 25 Datong Road, Suzhou, Jiangsu, China
PRODUCTCATALOGUESUZHOU DELFINOENVIRONMENTAL TECHNOLOGYCO., LTDwww.daruifuno.com
+86-18013144571
info@daruifuno.com
Room 301, Building 3, No. 25 Datong Road, Suzhou, Jiangsu, China
Aboutus01
02More+Certificate
03BusinessScope
04Applicationfield
CONTENTSOnline PH/ORP Analyzer
APX1 Series PH/ORP Controllers……………………………………….........................01APX2 Series PH/ORP Controllers………………………………………….........……......03Dual Channel PH/ORP Controller...........................................................................05Online PH/ORP Sensor
Online PH/ORP Glass Sensors .…………………….………................................................06Online PH/ORP Plastic Shell Sensor………………………………..…..............................10Digital PH/ORP Analyzer
Digital PH/ORP Controller……………………............………....................................14Digital PH/ORP Sensor..……...………………............………....................................15Digital Dissolved Oxygen Analyzer
Digital Dissolved Oxygen Controller…………...................................................………........17Digital Dissolved Oxygen Sensor...……...……........……….................................................18Online Conductivity Analyzer
Online Conductivity Controller.…………………...……….....................................................21Online Conductivity Sensor....………………………….…….................................................22Digital Conductivity Analyzer
Digital Conductivity Controller.…………………...………....................................23Digital Conductivity Sensor....………………………….……...................................24Digital Salinity Sensor...........................……...................................................26Digital Turbidity Analyzer
Digital Infrared Turbidity Controller.……………...……….....................................................27Digital Infrared Turbidity Sensor....………………….……....................................................28Digital Laser Turbidity Sensor.............................................................................................31
Digital Suspended Solids Analyzer
Digital Suspended Solids Controller.……………....………....................................................32Digital Suspended Solids Sensor....………...……….…….....................................................33Digital COD Analyzer
Digital COD Controller……………………............….....……..................................................34Digital COD Sensor..……...………………............….....……..................................................35Digital Ammonia (NH4-N) Analyzer
Digital Ammonia (NH4-N) Controller………….........………...................................................36Digital Ammonia (NH4-N) Sensor...……...……........………..................................................37Online Chlorine Analyzer
Online Chlorine Controller.…………..........………...………............................384-20mA Chlorine Sensor......................................................................................................39Digital Chlorine Analyzer
Digital Chlorine Controller.…………..........………...……….......................................42RS485 Chlorine Sensor..................................…………………...……….............................43Digital Chlorophyll Analyzer
Digital Chlorophyll Controller........................................................................46Digital Chlorophyll Sensor............................................................................47Digital Blue Green Algae Analyzer
Digital Blue Green Algae Controller........................................................................48Digital Blue Green Algae Sensor............................................................................49Multi-parameter Controller
MCC100 Two-parameter Controller...............................................................................50MCC200 Multiparameter Controller................................................................................51CONTENTS
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 1 —
APX1SeriesOnline PH/ORP Controller
The Daruifuno APX series pH/ORP analyzers can be connected to a variety analogpHorORP sensors to realize the measurement of pH or ORP values in water. APX1 Series
Features
3.2 inch LCD screen
Password can be set
Quick calibration button
Calibration points can be set freely
Power failure protection, indefinite retention of parameters
Specification
Model APX1-C1 APX1-C1Z
Principle
PH Glass pH electrode (hydrogen ion concentration index)
ORP Platinum or gold electrodes (redox potential)
Display Range
PH 0~14pH
ORP ± 2000mV
Temp -10~150℃
Resolution PH: 0.01pH ORP: 1mV TEMP: 0.1℃
Accuracy 0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
Stability 0.05% of measuring range every 24 hours without accumulation
Repeatability Better than 0.1% of measuring range
Temp Compensation Automatic or manual (NTC10K/PT1000)
Relay Output Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp or cleancontrol
Digital Communication —— A two-wire RS485 interface, ModbusRTUCurrent Output A 0/4~20mA current Max. load 1000Ω
Language English
Display 128*64 3.2-inch graphic dot matrix LCD
Calibration Method PH: 3 points ORP: 2 points
Protection Grade IP66
Enclosure Material Enhanced ABS
Power Supply AC: 100~240V 50/60Hz or DC:18~36V
Dimension 100*100*120mm (Hole size 92*92mm)
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmWork Temperature 0~60℃, RH<95%, non-condensing
Storage Temperature -20~70℃, RH<55%, non-condensing
Installation Panel
Weight 450g
Power Consumption Max. 3W
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 2 —
APX1SeriesOnline pH/ORP Controller
Specification
Model APX1-C2 APX1-G2
Principle
PH Glass pH electrode (hydrogen ion concentration index)
ORP Platinum or gold electrodes (redox potential)
Display Range
PH 0~14pH
ORP ± 2000mV
Temp -10~150℃
Solution Ground N/A differential ground
Resolution pH: 0.01pH ORP: 1mV TEMP: 0.1℃
Accuracy 0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
Stability 0.05% of measuring range every 24 hours without accumulation
Repeatability Better than 0.1% of measuring range
Temp Compensation Automatic or manual (NTC10K/PT1000) Automatic or manual (NTC10K/PT1000)Converted at 25°C
Relay Output Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp or cleancontrol
Digital Communication A two-wire RS485, Modbus, JSON
Current Output Two 0/4~20mA current Max. load 1000Ω
Language English
Display 128*64 3.2-inch graphic dot matrix LCD
Calibration Method PH: 3 points, ORP: 2 points
PH: 3 points, ORP: 2 points
PH: 5 points multi-slope calibrationProtection Grade IP66
Enclosure Material Enhanced ABS
Power Supply AC: 100~240V 50/60Hz or DC:18~36V
Dimension 100*100*120mm (Hole size 92*92mm)
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmWork Temperature 0~60℃, RH<95%, non-condensing
Storage Temperature -20~70℃, RH<55%, non-condensing
Installation Panel
Weight 450g
Power Consumption Max. 3W
Features
3.2 inch LCD screen
Password can be set
Quick calibration button
Calibration points can be set freely
Power failure protection, indefinite retention of parameters
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 3 —
APX2SeriesAPX2 Series
Features
3.2 inch LCD screen
English interface
Password can be set
144*144*120mm dimension
Calibration points can be set freely
Time and historical data can be recorded
Temperature compensation function
Specification
Model APX2-C1 APX2-C1Z
Principle
PH Glass pH electrode (hydrogen ion concentration index)
ORP Platinum or gold electrodes (redox potential)
Display Range
PH 0~14pH
ORP ± 2000mV
Temp -10~150℃
Resolution PH: 0.01pH ORP: 1mV TEMP: 0.1℃
Accuracy 0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
Stability 0.05% of measuring range every 24 hours without accumulation
Repeatability Better than 0.1% of measuring range
Temp Compensation Automatic or manual (NTC10K/PT1000)
Relay Output Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp or cleancontrol
Digital Communication —— A two-wire RS485 interface, ModbusRTUCurrent Output A 0/4~20mA current Max. load 1000Ω
Language English
Display 128*64 3.2-inch graphic dot matrix LCD
Calibration Method PH: 3 points , ORP: 2 points , calibration points can be set freely
Protection Grade IP66
Enclosure Material Enhanced ABS
Power Supply AC: 100~240V 50/60Hz or DC: 18~36V
Dimension 144*144*120mm (Hole size 138*138mm)
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmWork Temperature 0~60℃, RH<95%, non-condensing
Storage Temperature -20~70℃, RH<55%, non-condensing
Installation Wall mounting, pipe clamp, panel
Weight 750g
Power Consumption Max. 3W
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 4 —
APX2SeriesAPX2 Series
Features
3.2 inch LCD screen
English interface
Password can be set
144*144*120mm dimension
Calibration points can be set freely
Time and historical data can be recorded
Temperature compensation function
Specification
Model APX2-C3 APX2-G4
Principle
PH Glass pH electrode (hydrogen ion concentration index)
ORP Platinum or gold electrodes (redox potential)
Display Range
PH 0~14pH
ORP ± 2000mV
Temp -10~150℃
Solution Ground N/A differential ground
Resolution pH: 0.01pH ORP: 1mV TEMP: 0.1℃
Accuracy 0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
Stability 0.05% of measuring range every 24 hours without accumulation
Repeatability Better than 0.1% of measuring range
Temp Compensation Automatic or manual (NTC10K/PT1000) Automatic or manual (NTC10K/PT1000)Converted at 25°C
Relay Output Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp or cleancontrol
Digital Communication A two-wire RS485, Modbus, JSON
Current Output Two 0/4~20mA current Max. load 1000Ω
Language English English and Chinese
Time Display Year/month/date hour/minute/second
Historical Data
10000 historical data can be recorded, Record the last 100 calibration maintenance data
Display 128*64 3.2-inch graphic dot matrix LCD
Calibration Method PH: 3 points; ORP: 2 points
PH: 3 points; ORP: 2 points
PH: 5 points multi-slope calibrationProtection Grade IP66
Enclosure Material Enhanced ABS
Power Supply AC: 100~240V 50/60Hz or DC:18~36V
Dimension 144*144*120mm (Hole size 138*138mm)
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmWork Temperature 0~60℃, RH<95%, non-condensing
Storage Temperature -20~70℃, RH<55%, non-condensing
Installation Wall mounting, pipe clamp, panel
Power Consumption Max. 3W
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 5 —
Dual Channel PH/ORP Controller
APX2SeriesFeatures
Connected to 2 pH or 2 ORP sensors, or 1 pH and 1 ORP sensor;
Two Channels are isolated from each other
Each channel can be connected to an independent temp. system. When pH, ORP and temp. are tested at the same time, algorithm inside
the meter can simultaneously evaluate the disinfection ability and
display pH, ORP, temp. and chlorine values. Meet pH/ORP monitoring, dosing control, and data signal remote
transmission at the same time. Application: swimming pools, water parks, water treatment and dosing, ultrafiltration, circulating water, and other occasions. Specification
Model APX2-PD-A APX2-PD-D
Measuring Objects 2 measurement channel inputs, pH or ORP can be selected arbitrarily
Principle
PH Glass pH electrode (hydrogen ion concentration index)
ORP Platinum or gold electrodes (redox potential)
Display Range PH: 0~14pH ORP: ± 2000mV Temp: -10~150℃Resolution PH: 0.01pH ORP: 1mV TEMP: 0.1℃
Accuracy 0.1% of the measuring range or ±0.02pH / ±2mV, take the larger one
Stability 0.05% of measuring range every 24 hours without accumulation
Repeatability Better than 0.1% of measuring range
Temp Compensation Automatic or manual (NTC10K/PT1000)
Relay Output Two SPST relays, Max. load 3A/250VAC, set high/low alarm, temp or cleancontrol
Digital Communication A two-wire RS485 interface, Modbus RTU and JSON
Current Output Two 0/4~20mA current Max. load 1000Ω
Time Display Year/month/date hour/minute/second
Historical Data Record 10000 historical data and the last 100 calibration maintenance dataValuation Object* Built-in matrix (equivalent to residual chlorine) 0~2.5mg/L
Support user-defined (20x20 matrix)
Linear correspondence (water sample stability)
Display 128*64 3.2-inch graphic dot matrix LCD
Calibration Method PH: 3 points ORP: 2 points, calibration points can be set freely
Material Enhanced ABS Protection Grade: IP66
Power Supply AC: 100~240V 50/60Hz DC: 18~36V
Dimension 144*144*120mm (Hole size 138*138mm)
Work Temperature 0~60℃, RH<95%, non-condensing
Storage Temperature -20~70℃, RH<55%, non-condensing
Installation Wall mounting, pipe clamp, panel
The objects marked with (*) in the table are only suitable for users to evaluate trends within a certain range, and shouldnot berelied on as measurement parameters.
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 6 —
Model ASP100E ASP101E ASR100EMeasuring Object PH PH ORP
Measuring Range 0~14pH ±2000mVIndicator Electrode
Blue low impedance hemispherical glass
membrane
PlatinumReference System Ag/AgCl reference electrode, double salt bridge, KCl gel
Electrode Material
Glass
annular ceramic hole
Glass
Dot-shaped ceramic hole
Glass
annular ceramicholeWorking Pressure
Medium and low temp environment: max. 0~4bar
High temp environment: 0~2bar
Working Temp
Medium and low temp environment: 0~80℃, continuously working
High temp environment: 80~100℃, continuously working for less than30minsSample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Zero (E0) pH ±0.25pH ±20mVSLOP% >95%
Temperature Unit PT100, PT1000, NTC10K customized
Dimension Standard: diameter 12mm/Length 120mm (customized)
Installation Dimension Anti-twist cap or PG13.5
Tail Lead Integral or split
ASPseriesOnline pH/ORP Sensor
These glass pH or ORP sensors are used in a variety of industrial, chemical andenvironmental applications. Online pH/ORP Glass Sensor
Specification
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 7 —
Specification
Model ASP120E ASP121E ASP122E ASP123E ASP124EMeasuring Object PH
Measuring Range 0~14pH
Indicator Electrode low impedance cylindrical glass membrane
Reference System Ag/AgCl reference electrode, double salt bridge, KCl gel
Electrode Material Glass+Dot-shaped ceramic hole
Glass+Porous
tetrafluoro ring
Glass+ceramicsandcoreWorking Pressure
Medium and low temp environment: max. 0~6bar
High temp environment: 0~3bar
Working Temp
Medium and low temp environment: 0~80℃, continuous work
High temp environment: 80~100℃, continuous work for less than 60 mins
Sample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Zero (E0) ±0.25pH
SLOP% >95%
Temperature Unit PT100, PT1000, NTC10K customized
Dimension Standard: diameter 12mm/Length 120mm (customized)
Installation Dimension PG13.5
Tail Lead Integral or split
Application
Strong
acid and alkali
Normal temp. pure water
Harsh industrial
process* Normal temp. desulfurization
Normal temp. hydrofluoricacidOnline pH/ORP Glass Sensor
Harsh industrial process: for example, industries containing high concentrations of heavy metals, heavymetals,organics, high chlorine, ammonia, chemicals, etc.
ASPseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 8 —
Specification
These glass pH sensors are used for high or low temperature environment of industrial andchemical process.
Model ASP125E ASP126E ASP127E ASP129E ASR125EASP128EMeasuring Object PH ORP PHMeasuring Range 0~14pH ±2000mV0~14pHIndicator Electrode low impedance cylindrical glass membrane PlatinumglassmembraneReference System Ag/AgCl reference electrode, double salt bridge, KCl gel
Electrode Material Glass+ceramic sand core
Working Pressure
Medium and low temp environment: max. 0~6bar
High temp environment: 0~3bar
max. 0~6barWorking Temp
Medium and low temp env: 0~100℃, continuous work
High temp env: 100~135℃, continuous work < 60 mins
High temp env work more than 40 times (clean water test env.)
-15~80℃,continuousworkSample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Zero (E0) ±0.25pH
SLOP% >95%
Temperature Unit PT100, PT1000, NTC10K customized
Dimension Standard: diameter 12mm/Length 120mm (customized)
Installation Thread PG13.5
Tail Lead Integral or split
Application
High temp. strong
acid and alkali
High temp. harsh industrial
process
High temp.
fermentation
process
High temp. pure water
High temp.
Industrial
process
Lowtemp.Online pH/ORP Glass Sensor
Harsh industrial process: for example, industries containing high concentrations of heavy metals, heavymetals,organics, high chlorine, ammonia, chemicals, etc.
ASPseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 9 —
Online pH/ORP Glass Sensor
Features
Glass shell pH or ORP combination electrode
The penetration speed is fast, the response is fast, not easy to block, and it is easy to clean
The reference electrode is Ag/AgCl, and the
reference is filled with KCL colorless high
temperature gel
The ring-type platinum ORP sensor has a wide
response range and is suitable for sewage
environments
Flat platinum ORP sensor is easier to clean and
polish, suitable for water purification environment
Specification
Model ASP200E ASR200E ASR201EMeasuring Object PH ORP
Measuring Range 0~14pH ±1500mV ±2000mVIndicator Electrode
Low resistance spherical
glass membrane
Platinum sheet platinumringReference System Ag/AgCl reference electrode, double salt bridge, KCl gel
Electrode Material Glass+Porous tetrafluoro
membrane
Glass+PTFE+Platinum sheet Glass+PTFE+PlatinumringWorking Pressure 0~2bar
Working Temp 0~100℃, continuous work
Sample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Zero (E0) ±0.25pH ±20mV
SLOP% >95%
Temperature Unit NTC10K PT100, PT1000, NTC10K customized
Dimension Standard: diameter 12mm/Length 120mm
Installation Thread PG13.5
Tail Lead Integral
ASPseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 10 —
Specification
pH combination electrode, low impedance spherical glass membrane, economical andpractical. Online pH/ORP Plastic Shell Sensor
Model ASP035 ASR035 ASR035G ASP036 ASR036Measuring Object PH ORP PH ORPMeasuring Range 0~14pH ±1500mV 0~14pH ±1500mVIndicator Electrode
spherical glass
membrane
Platinum sheet Golden sheet spherical glass
membrane
PlatinumsheetReference System Ag/AgCl reference electrode, KCl gel
Electrode Material Glass+Hollow Fiber Filament Glass+Porous tetrafluororingWorking Pressure Medium and low temp environment: max. 0~1bar
Medium and lowtempenvironment:max. 0~2bar
Working Temp Medium and low temp environment: 0~80℃, continuous work
Sample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Zero (E0) buffer solution:
6.86±0.3 pH
±20mV
buffer solution:
6.86±0.3 pH
±20mVSLOP% >95%
Temperature Unit NA
Dimension D12mm/L120mm (customized) D28mm/L160mm(customized)Installation Anti-twist cap 3/4” NPT pipe threadTail Lead Integral
ASPseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 11 —
Model ASP300V ASP300N ASP300T ASP400V ASP400NASP400TPH Range 0~14pH
Sensor Material ABS+glass+porous PTFE diaphragm PPS+glass+porous PTFEdiaphragmReference System Double salt bridge, Ag/AgCl, KCL solid gel
Zero (E0) PH ±0.25pH
SLOP% >95%
Sample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Working Pressure Below 60℃: 0~4Bar, 60~80℃: 0~2Bar
Medium and low temp. Env. MAX: 0~6Bar;High temp. Env.: 0~3Bar
Working TEMP
0~60℃ continuous work
60~80℃ continuous work≤60mins
0~80℃ continuous work
80~100℃ continuous work≤60minsTemperature Unit Vacant NTC10K PT1000 Vacant NTC10K PT1000Glass Head Low impedance hemispherical glass membrane
Dimension Diameter: 35mm Length: 200 mm
Thread Size 1 inch NTP thread (both ends)
Lead Wire Standard 5m, other length can be customized
Wash Accessories Optional cleaning connector
Tail Lead Integral
Application Drinking water/Surface water/Industrial wastewater/Sewage
Online Plastic Shell PH Sensor
Features
Combination pH sensor
Fast response and accurate measurement
Built-in temperature unit: NTC10K, PT1000 or PT100
Cable length can be customized
Optional cleaning connector for automatic cleaning underwater
Specification
ASP300 ASP400ASPseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 12 —
Online Plastic Shell PH Sensor
Features
Combination pH sensor
Solution ground pH sensor
Fast response and accurate measurement
Built-in temperature unit: NTC10K, can be customized PT100, PT1000
Optional cleaning connector for automatic cleaning underwater
ASP500 is used for accurate detection of pure water environment; ASP600isusedforaccurate detection in heavily polluted environments.
ASP500 ASP600
Model ASP500N ASP600N
PH Range 0~14pH
Sensor Material PPS+glass
Solution Ground SUS316 platinum metal
Reference System Double salt bridge, Ag/AgCl
Zero (E0) PH ±0.25pH
SLOP% >95%
Sample Flow Rate 0.5 m/s ≥ flow velocity ≥ 0.001 m/s
Working Pressure Below 60℃: 0~4Bar, 60~80℃: 0~2Bar
Working TEMP
0~80℃ continuous work
80~100℃ continuous work≤60mins
Temperature Unit NTC10K (PT100 PT1000 customized)
Glass Head Low impedance hemispherical glass membrane
Dimension Diameter: 35mm Length: 200 mm
Thread Size 1 inch NTP thread (both ends)
Lead Wire Standard 5m, other length can be customized
Wash Accessories Optional cleaning connector
Tail Lead Integral
ASPseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 13 —
Online Plastic Shell ORP Sensor
Features
Combination ORP sensor
Ring-shaped or flat platinum detection head
Fast response and accurate measurement
Low noise cable, length can be customized
Optional cleaning connector for automatic cleaning underwater
Specification
Model ASR300 ASR301 ASR400 ASR401ORP Range ±1500mV ±2000mV ±1500mV ±2000mVReference Electrode Ag/AgCl
Electrolyte KCL Solid Gel
Detection Heads Flat platinum Ring-shaped platinum Flat platinum
Ring-shapedplatinumWorking Pressure Below 60℃: 0~4Bar, 60~80℃: 0~2Bar
Medium and low temp. Env. MAX: 0~6BarHigh temp. Env.: 0~3Bar
Working TEMP
0~60℃ continuous work
60~80℃ continuous work≤60mins
0~80℃ continuous work
80~100℃ continuous work≤60minsShaft Material ABS PPS
Membrane Porous Teflon membrane
Thread Size 1 inch NTP thread (both ends)
Dimension D: 35mm L: 200 mm
Lead Wire Standard 5m, length can be customized
Temperature Unit Default none, can customized NTC10K PT1000 PT100
Application Pure water/Drinking water/Surface water/Industrial wastewater/Sewage
Wash Accessories Optional cleaning connector
Tail Lead Integral
ASR300 ASR400ASPseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 14 —
Model DUC2-PR-A DUC2-PR-D
Sensor Input Single channel input digital pH or ORP sensor for water
Display
Range
PH -4~18pH (measuring range related to the connected sensor)
ORP ±2000mV (measuring range related to the connected sensor)
TEMP -10~500℃ /14~932℉ (measuring range related to the connectedsensor)Resolution
PH 0.01pH
ORP 0.1mV(-1000<ORP<1000); 1mV(-2000≤ORP≤-1000 or 1000≤ORP≤2000)TEMP 0.1℃/ 0.1℉
Relay Control Two settable SPST relays, Max. Load 3A/250VAC
Current Output Two settable 0/4~20mA current, Max. Load 1000Ω
Digital Output Two-wire RS485 interface; MODBUS RTU
Display Screen 128*64 3.2-inch large graphic dot matrix LCD
Configuration Power off protection, parameters are retained indefinitely
Time and Data Display year/month/day/hour/minute/second, record 10000 historical dataMaintenance Record Last 100 times
Language English
Protection Grade IP66
power failure protection Setup data is permanently retained when power off
Operating Environment 0~60℃,RH<95% ( no condensation)
Storage Environment -20~70℃,RH<55% ( no condensation)
Enclosure Material Enhanced ABS
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Method Wall mounting, pipe clamping, panel
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmPower Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 24W
Weight About 1600g
DUC2-PRDigital pH/ORP Analyzer
Universal controller specially designed for Daruifuno digital pH or ORP sensors. Digital pH/ORP Controller
Features
3.2 inch LCD screen
Various installation methods
10000 historical data can be recorded
0/4-20mA current output and RS485 interface
Specification
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 15 —
DPH/DRHseriesDigital pH/ORP Sensor
Features
Compact all-in-one design
Support handheld devices and in-situ applications
Large capacity reference, long service life
1\" NPT mounting thread for flexible installation
Internal storage of calibration data
Support offline calibration, on-site plug and play
Optional cleaning connector for underwater cleaning
Standard Modbus protocol, support access to standard industrial
control system
Specification
Model DPH790 DRH790
Electrical Isolation Electrical isolated communication and power interfaces
Measuring Object pH ORP
Measuring Technology Electrochemical glass electrode Electrochemical platinumelectrodesMeasuring Range pH: 0~14pH TEMP: 0~50℃ ORP: ±2000mV TEMP: 0~50℃Resolution 0.01pH / 0.1℃ ±1mV / 0.1℃Accuracy
0.1% of the range or ±0.02pH, take
the larger one; Temp: ± 0.5℃
0.1% of the range or ±2mV,
take the larger one; Temp: ±0.5℃Communication RS485 MODBUS-RTU
Temp Unit Automatic Temp compensation Temp measurement
Response Time T90<10s
Calibration Method Zero position calibration and slope calibration
Work Pressure 0~4Bar
Sample Flow Rate 0.5m/s≥flow rate≥0.001m/s
Operating Temp 0~50℃ (does not freeze)
Storage Temp 0~60℃ (does not freeze)
Shell Material ABS or PPS
Dimension Diameter: 35mm Length: 220 mm (protective claw included)
Mounting Thread 1 inch NPT at both ends; Immersed or piped installation
Lead interface Integral or split M16 connector
Protection Grade IP68
Power Supply 9~24V DC
Power Consumption 0.2W
Weight 200g
Cable Standard 5 meters (other length can be customized)
DPH790 DRH790
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 16 —
Digital pH/ORP Sensor
Features
Quick change of pH or ORP measurement unit
Internal storage of calibration data
Support offline calibration, on-site plug and play
Standard Modbus protocol, support access to standard
industrial control system
Specification
Model DPH890 DRH890
Electrical Isolation Electrical isolated communication and power interfaces
Measuring Object pH ORP
Measuring Technology Electrochemical glass electrode Electrochemical platinumelectrodesMeasuring Range pH: 0~14pH TEMP: 0~50℃ ORP: ±2000mV TEMP: 0~50℃Resolution 0.01pH / 0.1℃ 1mV / 0.1℃Accuracy
0.1% of the range or ±0.02pH, take
the larger one; Temp: ±0.5℃
0.1% of the range or ±2mV,
take the larger one; Temp: ±0.5℃Communication RS485 MODBUS-RTU
Temp Unit Automatic Temp compensation Temp measurement
Response Time T90<10s
Calibration Method Zero position calibration, slope calibration, offset calibration
Work Pressure 0~1Bar
Sample Flow Rate 0.5m/s≥flow rate≥0.001m/s
Operating Temp 0~50℃ (does not freeze)
Storage Temp 0~60℃ (does not freeze)
Shell Material POM+SS 316L or POM+Titanium alloy
Dimension
Diameter: 38mm length: 270 mm
(Body:D 38mm L 270mm Head: D 27mm L 115mm)
Mounting Thread Immersed or piped installation (Requires mounting accessory support)
Lead interface Integral or split M16 connector
Protection Grade IP68
Power Supply 9~24V DC
Power Consumption 0.2W
Weight 550g
Cable Standard 5 meters (other length can be customized)
DPH890
DPH/DRHseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 17 —
DUC2-DODigital Dissolved OxygenAnalyzerUniversal controller specially designed for Daruifuno digital dissolved oxygen sensors. Digital Dissolved Oxygen Controller
Features
3.2 inch LCD screen
Password can be set
10000 historical data can be recorded
Specification
Model DUC2-DO-A DUC2-DO-D
Sensor Input Single channel input digital dissolved oxygen sensor for water
Display
Range
DO 0~50mg/L or 0~50ppm (measuring range related to the connectedsensor)
saturation 0~500% (measuring range related to the connected sensor)
TEMP -10~500℃ /14~932℉ (measuring range related to the connectedsensor)
Resolution
DO 0.01mg/L or 0.01ppm
saturation 0.1% (0≤saturation<10); 1% (10≤saturation≤500)
TEMP 0.1℃/ 0.1℉
Relay Control Two settable SPST relays, Max. Load 3A/250VAC
Set high/low alarm, temperature and wash control
Current Output Two settable 0/4~20mA current, Max. Load 1000Ω
Digital Output Two-wire RS485 interface; MODBUS RTU
Display Screen 128*64 3.2-inch large graphic dot matrix LCD
Configuration Power off protection, parameters are retained indefinitely
Time and Data Display year/month/day/hour/minute/second, record 10000 historical dataMaintenance Record Last 100 times
Language English
Protection Grade IP66
power failure protection Setup data is permanently retained when power off
Operating Environment 0~60℃,RH<95% ( no condensation)
Storage Environment -20~70℃,RH<55% ( no condensation)
Enclosure Material Enhanced ABS
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Wall mounting, pipe clamping, panel
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmPower Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 24W
Weight About 1600g
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 18 —
OPDseriesDigital Dissolved Oxygen Sensor
Features
Fluorescence principle
Without consuming oxygen, no flow rate limitation
Based on digital and lightweight designed sensor
Can be easily connected with online transmitters, DTU, portable instruments
RS485 Modbus protocol, support access to standard industrial control system Protection grade IP68, can work continuously under water for a long time
Titanium metal housing, suitable for seawater environment
Internal storage of calibration data, support offline calibration, plug and play
Specification
Model OPD700 OPD701
Measuring Technology Luminescence optical measurement
Measuring Range
Dissolved oxygen: 0.00~20.00mg/L
Saturation: 0~200%
Temp: 0~50℃
Resolution Dissolved oxygen: 0.01mg/L Saturation: 1% Temp: 0.1℃Accuracy
Dissolved oxygen: ±0.3mg/L
Saturation: ±3%
Temp: 5~45℃ ±0.5℃
Dissolved oxygen: ±0.1mg/LSaturation: ±1%Temp: 0~50℃±0.2℃Response Time T90<60s
Digital Output RS485, Modbus RTU
Related Compensation Temperature/salinity/pressure compensation
Calibration Zero and span calibration
Sample Flow Rate Not dependent
Work Pressure 0~6Bar
Work Temp 0~50℃
Storage Temp -10~60℃
Material Titanium alloy
Power Supply DC 6~12V
Consumption 0.1W
Dimensions Diameter: 22mm Length: 160mm
Installation Submersible; Thread specifications: M22*1.5mm
Lead Interface M16
Protection Grade IP68
Cable Standard 5 meters (other length can be customized)
Weight 100g
Application Freshwater or seawater aquaculture Industrial process, sewage14
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 19 —
Digital Dissolved Oxygen Sensor
Features
Fluorescence principle
Based on digital and lightweight designed sensor
Can be easily connected with online transmitters, DTU, portable instruments
RS485 Modbus protocol, support access to standard industrial control system Protection grade IP68, can work continuously under water for a long time
Optional cleaning nozzle for underwater cleaning
Internal storage of calibration data, support offline calibration, plug and play
Specification
Model OPD790
Measuring Technology Luminescence optical measurement
Measuring Range
Dissolved oxygen: 0.00~20.00mg/L
Saturation: 0~200%
Temp: 0~50℃
Resolution Dissolved oxygen: 0.01mg/L Saturation: 1% Temp: 0.1℃Accuracy Dissolved oxygen: ±0.1mg/L Saturation: ±1% Temp: ±0.2℃Response Time 0~100% T90<25s, 100~0% T90<30s
Digital Output RS485, Modbus RTU
Related Compensation Temp/salinity/pressure compensation
Calibration Zero and span calibration
Work Pressure ≤3Bar
Sample Flow Rate Not dependent
Work Temp 0~50℃
Storage Temp -10~60℃
Material Body: PPS Sensor head: 316L SS
Power Supply DC 6~12V
Consumption 0.1W
Dimensions Diameter: 35mm Length: 250mm
Installation Information 1” NPT thread at both ends
Lead interface M16
Protection Grade IP68
Cable Standard 5 meters (other length can be customized)
Weight 260g
Application Surface water, sewage, wastewater, industrial process
OPDseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 20 —
OPTODseriesDigital Dissolved Oxygen Sensor
Features
A low power consumption dissolved oxygen sensor
ASTM International Method D888-05 and Standard ISO 17289
Based on digital and lightweight designed sensor
Can be easily connected with online transmitters, DTU
RS485 Modbus protocol, support access to industrial control system
Protection grade IP68, can work continuously under water for a long time
Internal storage of calibration data, support offline calibration, plug and play
Specification
Model OPTOD-S OPTOD-T OPTOD-P
Measuring Technology Luminescence optical measurement
Measuring Range
Saturation: 0~200%
Dissolved oxygen: 0.00~20.00mg/L 0.00~20.00ppm
Temp: 0~50℃
Resolution Dissolved oxygen: 0.01mg/L Saturation: 1% Temp: 0.1℃Accuracy Dissolved oxygen: ±0.1mg/L Saturation: ±1% Temp: ±0.1℃Response Time 0~100% T90<40s, 100~0% T90<65s
Water Move No necessary move
Frequency of Measure >5s
Digital Output RS485, Modbus RTU and SDI-12
Related Compensation Temp/salinity/pressure compensation
Calibration Zero and span calibration
Work Pressure 0~5Bar
Work Temperature 0~50℃
Storage Temp -10~60℃
Material 316L SS Ti POM
Power Supply DC 5~12V
Dimensions Diameter: 25mm Length: 150mm
Diameter 27mm, length150mmAdd protection head: length170mmLead interface Integral
Connection
Default barewires (9 armoured connectors, polyurethane jacket, waterproofFisher connector need to be customized)
Protection Grade IP68
Installation Information Immersed or piped installation (Requires mounting accessory support)
Cable Standard 7 meters (other length can be customized)
Consumption
Standby : 25 µA
Average RS485 (1 measure/seconde) : 4.4 µA
Average SDI12 (1 measure/seconde) : 7.3 mA
Current pulse : 500 mA Heating time : 100 mA
Application Surface water, sewage, industrial effluent, urban wastewater
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 21 —
AEC1seriesOnline Conductivity Analyzer
Universal controller specially designed for Daruifuno analog conductivity sensors. Online Conductivity Controller
Features
3.2 inch LCD screen
English interface
IP66 protection grade
Password can be set
Temperature compensation function
Specification
Model AEC1-T1 AEC1-T2
Principle Two electrode
Display
Range
Conductivity 0.00~20.00 mS/cm
Resistivity 0.00Ω.cm~18.00MΩ.cm
TDS 0.00~10g/L
Salinity 15ppt
Temp -10~150℃
Resolution
EC: 0.001µS /cm Resistivity: 0.01MΩ.cm
TDS: 0.01mg/L Salinity: 0.01% Temp: 0.1℃Accuracy EC: ±1% FS Temp: 0.5℃
Repeatability ±0.3% FS
Temp Compensation Automatic or manual (NTC10K or PT1000)
Relay Output
Two SPST relays, maximum load 3A/250VAC
Set high/low alarm, temperature and wash control
Communication N/A 2-wire RS485 interface, MODBUSRTUSignal Output Two 0/4~20mA current, Max. load 1000Ω
Configuration Power failure protection, indefinite retention of parameters
Language English
Display 128*64 3.2-inch large graphic dot matrix LCD
Protection Grade IP66
Enclosure Material Enhanced ABS
Power Supply AC: 100~240V 50/60Hz or DC: 18~36V
Dimension 100*100*120mm (hole size 92*92mm)
Work Temperature 0~60℃, RH<95%, non-condensing
Storage Temperature -20~70℃, RH<55%, non-condensing
Installation Method Panel
Power Consumption 3W
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 22 —
Model ASCK-K1 ASCK-K0.1 ASCK-K0.01
Measuring Principle 2 electrode
K Constant K=1 K=0.1 K=0.01
Measuring Range 5~2000μS/cm 0.5~200μS/cm 0.05~20μS/cm
TEMP Compensation PT1000
Work Temperature 0~100℃
Work Pressure 5Bar
Electrode Materials 316L SS
Installation Method 1/2” NPT
Cable Length Standard 10 meters
ASCseriesOnline Conductivity Sensor
Graphite 2-pole conductivity sensor
Model ASC100 ASC300
Measuring Principle 2 electrode
K Constant K=1
Measuring Range 0~10mS/cm
TEMP Compensation PT1000, NTC10K, support customized
Working Temperature 0~80℃
Working Pressure 1 Bar 4Bar
Packaging Materials Graphite ABS
Dimensions
Diameter12mm
length 120mm
Diameter 35mm
length 200mm
Installation Method Anti-twist cap or PG13.5 1\"NPT pipe thread
Tail Lead Integral Integral or split
Cable Length Standard 5 meters (customized) ASC300NStainless steel 2-pole conductivity sensor
ASCK
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 23 —
DUC2-ECDigital Conductivity Analyzer
Universal controller specially designed for Daruifuno digital conductivity sensors. Digital Conductivity Controller
Features
3.2 inch LCD screen
Password can be set
10000 historical data can be recorded
Automatic temperature compensation
Specification
Model DUC2-EC-A DUC2-EC-D
Sensor Input Single channel input digital conductivity sensor for water
Display
Range
Conductivity 0~999.99mS/cm (measuring range related to the connected sensor)
Resistivity 0~99.99MΩ.cm (measuring range related to the connected sensor)
TDS 0~999999ppm (measuring range related to the connected sensor)
Salinity 0~1000ppt (measuring range related to the connected sensor)
Temp -10~500℃ /14~932℉ (measuring range related to the connectedsensor)Resolution
Conductivity
0.001µS /cm(0~10µs/cm) 0.01µS /cm(10~100µs/cm)
0.1µS /cm(100~1000µs/cm) 1µS /cm(1000~10000µs/cm)
0.01mS/cm(10~999.99mS/cm)
Resistivity 1Ω.cm(0≤resistivity<1000000) 0.01MΩ.cm(1≤resistivity≤99.99)
TDS 1ppm
Salinity 0.01ppt
Temp 0.1℃/ 0.1℉
Relay Control Two settable SPST relays, Max. load of 3A/250VAC
Set high/low alarm, temperature and wash control
Current Output Two settable 0/4~20mA current, Max. load 1000Ω
Digital Output 2-wire RS485 interface, MODBUS RTU
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rateConfiguration Power off protection, parameters are retained indefinitely
Time and Data Display Year/month/day/hour/min/second, record 10000 historical dataMaintenance Record Last 100 times
Work Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃,RH<55% ( no condensation)
Enclosure Material Enhanced ABS
Protection Grade IP66
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Wall mounting, pipe clamping, panel
Power Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 24W
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 24 —
DECseriesDigital Conductivity Sensor
Features
Compact all-in-one design
Support handheld devices and in-situ applications
1” NPT mounting thread for flexible installation
Internal storage of calibration data
Support offline calibration, on-site plug and play
Optional cleaning nozzle for underwater cleaning
Standard Modbus protocol, support access to standard industrial
control system
Specification
Model DEC790
Electrical Isolation Electrical isolated communication and power interfaces
Measuring Technology 2-electrod conductivity
Measuring Range Conductivity: 0~10mS/cm; TDS: 0~5g/L; Salinity: 5ppt(‰); Temp: 0~50℃Resolution Conductivity: 0.01uS/cm; TDS: 0.01mg/L; Salinity: 0.01%; Temp: 0.1℃Accuracy ±1.0% FS
Communication RS485 MODBUS-RTU
Temp Unit Automatic Temp compensation
Response Time T90<15s
Calibration Method Multi-point calibration of standard solutions; Contrast Offset; Factor offset
Work Pressure ≤6Bar
Sample Flow Rate Not dependent
Operating Temp 0~50℃ (does not freeze)
Storage Temp -10~60℃ (does not freeze)
Shell Material ABS or PPS
Dimension Diameter: 35mm Length: 280 mm (protective claw included)
Mounting Thread 1 inch NPT at both ends; Immersed or piped installation
Lead interface Split M16 connector
Protection Grade IP68
Power Supply 9~24V DC
Power Consumption 0.2W
Weight 220g
Cable Standard 5 meters (other length can be customized)
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 25 —
Digital Conductivity Sensor
Features
Quick change of the measurement unit
Internal storage of calibration data
Support offline calibration, on-site plug and play
Standard Modbus protocol, support access to standard
industrial control system
Specification
Model DEC890
Electrical Isolation Electrical isolated communication and power interfaces
Measuring Technology 2-electrod conductivity
Measuring Range
Conductivity: 0~10mS/cm
TDS: 0~5g/L
Salinity: 5ppt(‰)
Temp: 0~50℃
Resolution
Conductivity: 0.01uS/cm
TDS: 0.01mg/L
Salinity: 0.01%
Temp: 0.1℃
Accuracy ±1.0% FS
Communication RS485 MODBUS-RTU
Temp Unit Automatic Temp compensation
Response Time T90<15s
Calibration Method Multi-point calibration of standard solutions; Contrast Offset; Factor offset
Work Pressure ≤1Bar
Sample Flow Rate Not dependent
Operating Temp 0~50℃ (does not freeze)
Storage Temp -10~60℃ (does not freeze)
Shell Material POM+SS 316L or POM+Titanium alloy
Dimension
Diameter: 38mm length: 270 mm
(Body:D 38mm L 270mm Head: D 27mm L 115mm)
Mounting Thread Immersed or piped installation (Requires mounting accessory support)
Lead interface Split M16 connector
Protection Grade IP68
Power Supply 9~24V DC
Power Consumption 0.2W
Weight 550g
Cable Standard 5 meters (other length can be customized)
DECseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 26 —
Digital Salinity/Conductivity Sensor
Features
Protection grade IP68, can work continuously under water for a
long time
Standard Modbus protocol, support access to standard
industrial control system
No polarization, can be used continuously online
Extremely wide range, wider application
Very resistant to pollution, strong anti-interference ability
Stable measurement and higher accuracy
Strong and durable structure, longer service life
Specification
Model DEC350 DEC351
Measuring Object Salinity Conductivity
Measuring Principle 4-electrode
Measuring Range
Salinity: 0~80ppt (‰)
Temp: 0~50℃
Conductivity: 0~100 mS/cmTemp: 0~50℃Resolution 0.01% 0.1uS/cm
Accuracy ±1%FS ±1% FS
Response Time T90<15s
Temp Compensation Automatic, built-in temp unit
Digital Output RS485, Modbus
Calibration Method contrast bias correction; factor correction
Sample Flow Rate Not dependent
Work Pressure ≤6Bar
Work Temperature 0.0~50.0℃ (does not freeze)
Storage Temp -10~60℃
Shell Material Ti+PEEK+Nickel
Dimension Diameter: 23mm Length: 180mm Diameter: 23mmLength: 180mmInstallation Submersible; Thread specifications: M22*1.5mm
Lead interface M16
Protection Grade IP68
Power Supply 6~12V DC
Weight 105g
Cable Standard 5 meters(customized)
Power Consumption 0.2W
DECseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 27 —
Digital Infrared Turbidity AnalyzerUniversal controller specially designed for Daruifuno digital infrared turbidity sensors. Digital Infrared Turbidity Controller
Features
3.2 inch LCD screen
Password can be set
10000 historical data can be recorded
Support a variety of installation methods
Specification
Model DUC2-TU-A DUC2-TU-D
Sensor Input Single channel input digital turbidity sensor for water
Display Range
TU: 0~4000NTU SS: 0~3500mg/L Temp: -10~500℃(measuring range related to the connected sensor)
Resolution
TU: 0.01 NTU(0~100NTU) 0.1NTU(10~1000NTU) 1NTU(1000~4000NTU)
SS: 1mg/L
Temp: 0.1℃ or 0.1℉
Relay Control Two settable SPST relays, Max. load of 3A/250VAC
Set high/low alarm, temperature and wash control
Current Output Two settable 0/4~20mA current, Max. load 1000Ω
Digital Output 2-wire RS485 interface, MODBUS RTU
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration Power off protection, parameters are retained indefinitely
Time or Data Display Year/month/day/hour/min/second, record 10000 historical dataMaintenance Record Last 100 times
Language English
Protection Grade IP66
Work Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃,RH<55% ( no condensation, precision instruments)
Enclosure Material Enhanced ABS
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Wall mounting, pipe clamping, panel installation
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmPower Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 24W
Weight About 1600g
DUC2-TU
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 28 —
OPTUseriesDigital Infrared Turbidity Sensor
Features
Compact all-in-one design
Support handheld devices and in-situ applications
1\" NPT mounting thread for flexible installation
Internal storage of calibration data
Support offline calibration, on-site plug and play
Optional cleaning nozzle for underwater cleaning
Standard Modbus protocol, support access to standard
industrial control system
Specification
Model OPTU790
Electrical Isolation Electrical isolated communication and power interfaces
Measuring Technology Infrared scattering principle
Measuring Range 0.01~1000NTU
Resolution 0.01NTU
Accuracy Better than 5% of measured value or 0.3NTU, take the larger oneCommunication RS485 MODBUS-RTU
Temp Unit Temp measurement
Response Time T90<15s
Calibration Method Offset; Factor offset
Work Pressure ≤6Bar
Sample Flow Rate Not dependent
Operating Temp 0~50℃ (does not freeze)
Storage Temp -10~60℃ (does not freeze)
Shell Material PPS, Ti, glass
Dimension Diameter: 35mm Length: 215 mm
Mounting Thread 1 inch NPT at both ends; Immersed or piped installation
Lead interface Split M16 connector
Protection Grade IP68
Power Supply 6~12V DC
Power Consumption 0.2W
Weight 220g
Cable Standard 5 meters (other length can be customized)
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 29 —
Digital Infrared Turbidity Sensor
Features
Based on the infrared absorption and scattering light method
Use ISO7027 method to continuously and accurately determine turbidity and
suspended solids in water
LED infrared scattering light source (860nm), stable wavelength, stable data
Reliable performance, simple installation and calibration
Self-diagnostic function, built-in humidity sensor and a light source detector
Internal storage of calibration data, support offline calibration, plug and play
Standard Modbus protocol, support access to standard industrial control systemSpecification
Model OPTU850Z OPTU851Z
Electrical Isolation Electrical isolated communication and power interfaces
Measuring Technology Infrared scattering principle
Measuring Range
Turbidity: 0.01~1000NTU
Suspended solids: 1~3000mg/L
Turbidity: 0.01~4000NTUSuspended solids: 1~3000mg/LResolution 0.01NTU/1mg/L 0.01NTU/1mg/L
Accuracy
Better than 5% of measured value
or 0.3NTU, take the larger one
Better than 5%of measuredvalueor1NTU, take the larger one
Communication RS485 MODBUS-RTU
Related Configuration Humidity alarm
Response Time T90<15s
Calibration Method Multi-point calibration; Contrast Offset; Factor offset
Work Pressure ≤4Bar
Sample Flow Rate Not dependent
Operating Temp 0~50℃ (does not freeze)
Storage Temp -10~60℃ (does not freeze)
Shell Material 316L stainless steel
Dimension Diameter: 52mm length: 260 mm
Mounting Thread Horizontal installation, dedicated 90° mounting accessories
Lead interface Split M16 connector
Protection Grade IP68
Power Supply 9~24V DC
Power Consumption 0.6W
Weight 700g
Cable Standard 5 meters (other length can be customized)
OPTUseries
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 30 —
NTUDigital Turbidity Sensor
Features
Slim and robust design
Use ISO 7027 method for monitoring waters with low to strong turbidity
Based on an infrared light measurement according to the 90° scattered light
method
Light measurement at a wavelength of 880 nm
Can measure Suspended Solid 0-4500 mg/L
Store calibration data and history directly in the sensor
Specification
Measure Principle Turbidity : Diffusion IR at 90° Measure Ranges
5 to 4000 NTU in 5 ranges: 5 ~ 50 NTU
5 ~ 200 NTU
5 ~ 1000 NTU
5 ~ 4000 NTU
AUTOMATIC
0 to 4500 mg/L
Calibration :
0-500 mg/L according to NF EN872
>500 mg/L according to NF T 90 1052Resolution 0.01 to 1 NTU/mg/L
Accuracy <5% of the reading
Temp Unit NTC
Temp Range 0.00°C ~+ 50.00°C (does not freeze)
Temp Resolution 0.01℃
Temp Accuracy ± 0.5 °C
Response Time T90<15s
Storage Temp 0°C ~+ 60°C
Dimension Diameter : 27 mm; length : 170 mm
Weight 300g (sensor + cable 7 meters)
Wetted Material Head of the sensor : PVC Body : DELRIN Optical part : Quartz
Cable : polyurethane jacket Steam gland : Polyamide
Safeway
The optical windows are vulnerable to:
chemicals (organic solvents, acids and strong bases, peroxide, hydrocarbons)
mechanical treatments (impact, abrasion). Maximum Pressure 5 bars
IP Classification IP68
Connection 9 armoured connectors, polyurethane jacket, bare-wires
Sensor Cable
Standard : 3, 7 and 15 m (other length on request). 100 m Max. Up to 100 m with junction box. Signal Interface Modbus RTU RS-485 and SDI-12
Power Supply
5 to 12 volts for cable 0-15 m
7 to 12 volts for cable >15 m Max. 13.2 V
Consumption
Standby : 40 µA
Average RS485 (1 measure/seconde) : 820 µA
Average SDI12 (1 measure/seconde) : 4.2 mA
Current pulse : 500 mA Heating time : 100 mS
Protection against the inversions of polarity
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 31 —
OLTUseriesDigital Laser Turbidity Sensor
Specification
The flow turbidity sensor shoots the 660nm laser vertically downwards into
the water. The light is scattered by suspended particles in the water sample, and the scattered light at 90°with the incident angle is received by the
silicon photocell receiver immersed in the water sample, and 90 °is
calculated. Compact miniaturized design, small installation space
660nm laser light source with high resolution and fast response
Optional viewing window and automatic emptying system reduce
maintenance effort
Low injection flow requirements, reducing the amount of waste
generated in the measurement
Internal storage of calibration data, support offline calibration, on-site
plug and play
Model OLTU600 OLTU601
Measuring Technology 660nm Laser Scattering Principle
Measuring Range
Turbidity: 0.001~100NTU
Temp: 0~45℃
Resolution
Turbidity: 0.001NTU
Temp: 0.1℃
Accuracy
0.001~40NTU is ± 2% of reading or ±0.015NTU, take the larger one;40~100NTU is ± 5% of reading
Communication RS485 MODBUS-RTU
Display LED light OLED screen
Operation Panel Via PC or controller operation buttons
Response Time Step response, the initial response time<60 seconds
Related Measurement Temp measurement
Calibration Method Multi-point calibration; Contrast Offset; Factor offset
Sample Pressure Ensure that the sample pressure is 1~2bar before the injection port
Sample Flow Rate 100~700mL/min, ideal flow: 200~300mL/min
Operating Temp 0~45℃ (does not freeze)
Storage Temp -10~60℃
Shell Material POM+nylon+ABS+stainless steel
Dimension 140*140*330mm
Installation Main body wall mount
Lead interface M12
Protection Grade IP65
Power Supply 9~18V DC
Power Consumption 2.5W
Weight 2100g
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 32 —
Model DUC2-SS-A DUC2-SS-D
Sensor Input Single channel input digital SS sensor for water
Display Range
SS: 0~500g/L or 0~500000ppm Temp: -10~500℃(measuring range related to the connected sensor)
Resolution
SS: 1mg/L (0~1000mg/L) 0.001g/L (1~10g/L), 0.01g/L (10~100g/L), 0.1g/L(100~500g/L) 1ppm
Temp: 0.1℃
Relay Control Two settable SPST relays, Max. load of 3A/250VAC
Set high/low alarm, temperature and wash control
Current Output Two settable 0/4~20mA current, Max. load 1000Ω
Digital Output 2-wire RS485 interface, MODBUS RTU
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration Power off protection, parameters are retained indefinitely
Time or Data Display Year/month/day/hour/min/second, record 10000 historical dataMaintenance Record Last 100 times
Language English
Protection Grade IP66
Work Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃,RH<55% ( no condensation, precision instruments)
Enclosure Material Enhanced ABS
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Wall mounting, pipe clamping, panel installation
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmPower Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 24W
Weight About 1600g
DUC2-SSDigital Suspended Solids AnalyzerUniversal controller specially designed for Daruifuno digital suspended solids sensors. Digital Suspended Solids Controller
Features
3.2 inch LCD screen
Password can be set
10000 historical data can be recorded
Support a variety of installation methods
Specification
6
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 33 —
MLSSseriesSpecification
Using 880nm infrared light double beam scattered light to
measure sludge concentration
Multi-range, fast response
Used in High concentration sludge wastewater
RS-485 output, support Modbus
With self-cleaning wiper
Model MLSS300 (no wiper)
MLSS301 (with wiper)
MLSS310 (no wiper)
MLSS311 (with wiper)
MLSS320(nowiper)MLSS321(withwiper)Measuring Principle Infrared scattered light method
Measuring Range 0.01-20g/L 0.01-45g/L 0.01-120g/LAccuracy Less than 5% of the measured value
Resolution 0.01g/L
Response Time T90<60s
Calibration Factor calibration, multi-point calibration
Communication RS485, Modbus-RTU
Work Pressure ≤4bar
Work Temp 0~50℃ (does not freeze)
Storage Temp -10~60℃
Flow Rate Not dependent
Power Supply 12V DC
Dimensions Diameter 65mm * Length 270mm
Installation Horizontal installation, special 90° installation accessories
Material Body: SUS316L/ T i /PVC (option)+ POM
Protection Grade IP68
Cable Standard 10 meters
Weight 800g
Power Consumption 1.5W
Digital Suspended Solids Sensor
PVC SS316LFeatures
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 34 —
DUC2-CODDigital COD Analyzer
Universal controller specially designed for Daruifuno digital COD sensors. Digital COD Controller
Features
3.2 inch LCD screen
Password can be set
10000 historical data can be recorded
Support a variety of installation methods
Specification
Model DUC2-COD-A DUC2-COD-D
Sensor Input Single channel input digital COD sensor for water
Display Range
COD: 0~9999mg/L TOC: 0~9999mg/L BOD: 0~9999mg/L TU: 0~4000NTUTemp: -10~500℃ (measuring range related to the connected sensor)
Resolution
COD: 0.01mg/L(0~100), 0.1mg/L(100~1000), 1mg/L(1000~9999)
TOC: 0.01mg/L(0~100), 0.1mg/L(100~1000), 1mg/L(1000~9999)
BOD: 0.01mg/L(0~100), 0.1mg/L(100~1000), 1mg/L(1000~9999)
TU: 0.01NTU(0~100), 0.1NTU(100~1000), 1NTU(1000~4000)
Temp: 0.1℃
Relay Control Two settable SPST relays, Max. load of 3A/250VAC
Set high/low alarm, temperature and wash control
Current Output Two settable 0/4~20mA current, Max. load 1000Ω
Digital Output 2-wire RS485 interface, MODBUS RTU
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration Power off protection, parameters are retained indefinitely
Time or Data Display Year/month/day/hour/min/second, record 10000 historical dataMaintenance Record Last 100 times
Language English
Protection Grade IP66
Work Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃,RH<55% ( no condensation, precision instruments)
Enclosure Material Enhanced ABS
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Wall mounting, pipe clamping, panel installation
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmPower Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 24W
Weight About 1600g
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 35 —
COD351Digital COD Sensor
Features
RS-485 output, support Modbus
No reagents, no pollution, environmentally friendly
Can measure COD, TOC, turbidity and temperature
Automatically compensate for turbidity interference
With self-cleaning brush and the maintenance cycle is longer
Specification
The total amount of organic pollutants in the water can be measured by
measuring the degree of absorption of these organic substances to 254nm
wavelength ultraviolet light. The COD 351 digital sensor adopts two light sources, one 254nm ultraviolet
light, and one turbidity compensation, which can automatically eliminate the
interference of suspended substances in the water, so as to achieve more
stable and reliable measurement.
Model COD351L COD351H
Measuring Principle UV254 Absorption Method
Optical path 6mm 2mm
Measuring Range
COD: 0.75~500mg/L
TOC: 0.3~200mg/L
COD: 1~1500mg/L
TOC: 0.4~600mg/L
Resolution COD: 0.01mg/L TOC: 0.1mg/L
Accuracy ± 3% of the measurement + 0.5mg/L
Related Measurement TU: 0~300NTU accuracy: ± 5% TU: 0~1000NTU accuracy: ±5%Response Time >1min
Operating Tempe 0~45℃ (does not freeze)
Storage Temp -10~60℃
Calibration Method Standard solution
Protection Grade IP68
Working Pressure ≤1bar
Flow Rate not depend on
Power DC 12V~24V
Communication RS485, Modbus RTU protocol
Dimension Diameter 60mm, length 215mm
Lead Interface M16
Installation Investment, 1 inch NPT pipe thread
Shell Material 316L stainless steel+POM
Power Consumption
Normal measurement: 0.1W;
Automatic cleaning by mechanical wiper: 3W;
Abnormal jamming of mechanical wiper: 4.5W
Weight 720g
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 36 —
DUC2-NH4Digital Ammonia (NH4-N) AnalyzerUniversal controller specially designed for Daruifuno digital NH4-N sensors. Digital Ammonia (NH4-N) Controller
Features
3.2-inch LCD screen
Password can be set
10000 historical data can be recorded
Support a variety of installation methods
Specification
Model DUC2-NH4-A DUC2-NH4-D
Sensor Input Single channel input digital ammonia sensor for water
Display Range
NH4-N: 0~1000mg/L NH4+: 0~1000mg/L PH: -4~18pH Temp: -10~500℃(measuring range related to the connected sensor)
Resolution
NH4-N: 0.01mg/L(0~10), 0.1mg/L(10~100), 1mg/L(100~1000)
NH4+: 0.01mg/L(0~10), 0.1mg/L(10~100), 1mg/L(100~1000)
PH: 0.01pH
Temp: 0.1℃
Relay Control Two settable SPST relays, Max. load of 3A/250VAC
Set high/low alarm, temperature and wash control
Current Output Two settable 0/4~20mA current, Max. load 1000Ω
Digital Output 2-wire RS485 interface, MODBUS RTU
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration Power off protection, parameters are retained indefinitely
Time or Data Display Year/month/day/hour/min/second, record 10000 historical dataMaintenance Record Last 100 times
Language English
Protection Grade IP66
Work Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃,RH<55% ( no condensation, precision instruments)
Enclosure Material Enhanced ABS
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Wall mounting, pipe clamping, panel installation
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmPower Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 24W
Weight About 1600g
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 37 —
NH351Digital Ammonia (NH4-N) Sensor
Features
Adopt ion selective electrode (ISE) method
Digital sensor, RS-485 output, support MODBUS
No reagents, no pollution, environmentally friendly
With self-cleaning brush, longer maintenance cycle
Automatically compensate pH and temperature
Note: The ion electrode is only suitable for fresh water application scenarios, not for sea water. Specification
The online ammonia nitrogen sensor does not require reagents, is green and pollution-free, andcanbe monitored online in real time. Integrated ammonium, pH and reference electrodes to automaticallycompensate for pH and temperature in water.
Model NH351
Measuring Principle Ion selective electrode (ISE) method
Measuring Range NH4-N: 0~1000mg/L
Accuracy NH4-N: 5% of the measured value ± 0.2mg/L pH: 0.1pHResolution NH4-N: 0.01mg/L
Communication RS-485, MODBU-RTU
Related Measurement pH: 5.0~9.0pH (recommendation)
Response Time T90<2min
Temperature Range 0~45℃ (does not freeze)
Storage Temperature 0~50℃ (does not freeze)
Working Pressure ≤1bar
Sample Flow Rate 0.5m/s≥flow rate≥0.001m/s
Protection Grade IP68
Calibration Method Standard solution
Sensor Interface Support
Power Supply DC 9~24 V
Lead Interface M16
Shell Material POM
Dimension Diameter: 65mm Length: 275mm
Installation Investment, 1 inch NPT pipe thread
Power Consumption Normal measurement: 0.6W;
Automatic cleaning by mechanical wiper: 1.5W;
Abnormal jamming of mechanical wiper: 4.5WWeight 620g
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 38 —
ADS2-C3Online Chlorine Analyzer
Universal controller specially designed for Daruifuno membrane-covered ampere4-20mAoutput chlorine sensors. Online Chlorine Controller
Features
3.2-inch LCD screen
Password can be set
10000 historical data can be recorded
Support a variety of installation methods
Specification
Model ADS2-C3-A ADS2-C3-D
Measuring Object Residual chlorine
Measuring Principle membrane-covered, amperometric system
Sensor Input Compatible with all DRFN 4-20mA Version Chlorine Sensors
Measuring Range Max. 0.005~200ppm, related to sensors
Resolution Min. 0.001ppm, related to sensors
Temp. Compensation Automatic compensation
Calibration Method DPD comparison method, 1~2 points or more
Relay Control Two settable SPST relays, Max. load of 3A/250VAC
Current Output A settable 0/4~20mA current, Max. load 1000Ω
Digital Output 2-wire RS485 interface, MODBUS RTU, support JSON
Display Screen 3.2-inch black and white graphic LCD display, pixel 128*64 dot matrix LCDConfiguration Power off protection, parameters are retained indefinitely
Time or Data Display Year/month/day, hour/min/second, record 10000 historical dataMaintenance Record Record the last 100 calibration maintenance data, MCU over temperaturealarmlogLanguage English and Chinese
Protection Grade IP66
Work Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃,RH<55% ( no condensation, precision instruments)
Enclosure Material Enhanced ABS
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Wall mounting, pipe clamping, panel installation
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmPower Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 7W
Weight 1600g
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 39 —
CL4.2SeriesChlorine sensor with membrane-covered, amperometric
2-electrode system. For the measurement of free inorganic
chlorine at constant pH. CL4.2 Series
Specification
Indicator Free chlorine
pH Range 6~8pH
Pressure Range 0~1 bar, no pressure surges or fluctuations
Temperature Range 0~45℃
Temp Compensation Integrated automatic temperature compensation
Response Time T90 30 seconds
Flow Rate About 30 L/h, low flow-dependence
Shaft Length standard 175 mm, and up to 220 mm in length (mA-Version)
Connection 2-pole terminal or M12 male
Material PVC-U and semipermeable membrane
Scope of Supply sensor, membrane cap, electrolyte
Power Supply 12~30V DC
Signal Output 4~20mA
Application
Drinking water,fresh water, process water. The water must not contain any surfactants
pH-value must be constant. Model Range Resolution (ppm)
CL4.2MA0.5 0.005~ 0.500 ppm 0.001
CL4.2MA2 0.005~2.000 ppm 0.001
CL4.2MA5 0.05~5.00 ppm 0.01
CL4.2MA10 0.05~10.00 ppm 0.01
CL4.2MA20 0.05 ~20.00 ppm 0.01
CL4.2MA-100 0.5~100.0 ppm 0.1
CL4.2MA-200 0.5~ 200.0 ppm 0.1
Online 4-20mA Chlorine Sensor
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 40 —
CS4SeriesChlorine sensor with membrane-covered, amperometric
3-electrode system. For the measurement of free inorganic chlorine with
reduced pH-dependence, also in sea water. CS4 Series
Specification
Indicator Free chlorine
PH Range 4~9pH
Pressure Range 0~3 bar
Temperature Range 0~45℃
Temp Compensation Integrated automatic temperature compensation
Response Time T90 2min
Flow Rate About 30 L/h, low flow-dependence
Shaft Length standard 175 mm, and up to 220 mm in length (mA-Version)
Connection mA-version with 2-pole terminal or M12 male
Material
PVC-U, PEEK, stainless steel 1.4571
microporous hydrophilic membrane
Scope of Supply sensor, membrane cap, electrolyte
Power Supply 12~30V DC
Signal Output 4-20mA
Application
Fresh water and sea water at 10µS/cm-50mS/cm, especially for sewagesurfactants are partially tolerated
Model Range Resolution (ppm)
CS4MA2 0.005~2.000 ppm 0.001
CS4MA5 0.05~5.00 ppm 0.01
CS4MA10 0.05~10.00 ppm 0.01
CS4MA20 0.05~20.00 ppm 0.01
CS4MA200 0.5~200.0 ppm 0.1
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 41 —
CC1SeriesChlorine sensor with membrane-covered, amperometric
3-electrode system. For the measurement of free chlorine on the basis of
iso-cyanuric acid, also in seawater. CC1 Series
Specification
Model Range Resolution(ppm)
CC1MA2 0.005~2.000 ppm 0.001CC1MA5 0.05~5.00 ppm 0.01CC1MA10 0.05~10.00 ppm 0.01CC1MA20 0.05~ 20.00 ppm 0.01Indicator Free chlorine on the basis of iso-cyanuric acid
PH Range 4~12pH
Pressure Range 0~3bar
Temperature Range 0~45℃
Temp Compensation Integrated automatic temperature compensation
Response Time T90 2min
Flow Rate About 30 L/h, low flow-dependence
Shaft Length standard 175 mm, and up to 220 mm in length (mA-Version)
Connection mA-version with 2-pole terminal or M12 male
Material
PVC-U, PEEK, stainless steel 1.4571
microporous hydrophilic membrane
Scope of Supply sensor, membrane cap, electrolyte
Power Supply 12~30V DC
Signal Output 4~20mA
Application
Fresh water and sea water, swimming pool
Surfactants are tolerated in part
A special electrolyte is used for seawater
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 42 —
DDS2-C3Digital Chlorine Analyzer
Universal controller specially designed for Daruifuno membrane-covered ampereRS485output chlorine
Digital Chlorine Controller
Features
3.2-inch LCD screen
Password can be set
10000 historical data can be recorded
Support a variety of installation methods
Specification
Model DDS2-C3-A DDS2-C3-D
Software Version DRFN chlorine Analysis software V1.0
Sensor Input Compatible with all DRFN digital Version Chlorine Sensors
Display Range 0.00-200.00mg/L
Resolution 0.01 mg/L
Relay Control Two settable SPST relays, Max. load of 3A/250VAC
Current Output Two settable 0/4~20mA current, Max. load 1000Ω
Digital Output 2-wire RS485 interface, MODBUS RTU, support JSON
Display Screen 128*64 LCD, adjustable backlight mode, adjustable display rate
Configuration Power off protection, parameters are retained indefinitely
Time or Data Display Year/month/day/hour/min/second, record 1000 historical dataMaintenance Record Last 100 times
Protection Grade IP66
Work Temperature 0~60℃,RH<95% ( no condensation)
Storage Temperature -20~70℃,RH<55% ( no condensation, precision instruments)
Enclosure Material Enhanced ABS
Dimension 144*144*120 mm (hole size 138*138 mm)
Installation Wall mounting, pipe clamping, panel installation
Electrical Interface Reserve three M12*1.5 glan heads, the wire diameter is 3~6.5mmPower Supply AC: 100~240V 50/60Hz DC: 18~36V
Power Consumption About 7W
Weight About 800g
Web: www.daruifuno.com E-mail: info@daruifuno.com Tel: +8618013144571
— 43 —
CL4.2SeriesCL4.2 Series
Specification
Indicator Free chlorine
pH Range 6~8pH
Pressure Range 0~1 bar, no pressure surges or fluctuations
Temperature Range 0~45℃
Temp Compensation Integrated automatic temperature compensation
Response Time T90 30 seconds
Flow Rate About 30 L/h, low flow-dependence
Shaft Length standard 175 mm
Connection M12 male
Material PVC-U and semipermeable membrane
Scope of Supply sensor, membrane cap, electrolyte
Power Supply 9~30V DC
Signal Output RS485 Modbus RTU
Application
Drinking water,fresh water, process water. The water must not contain any surfactants
pH-value must be constant. Model Range Resolution (ppm)
CL4.2H-M0c 0.005~2.000 ppm 0.001CL4.2N-M0c 0.05~20.00 ppm 0.01
CL4.2L-M0c 0.5~200.0ppm 0.1
Online RS485 Chlorine Sensor
Chlorine sensor with membrane-covered, amperometric
2-electrode system. For the measurement of free inorganic
chlorine at constant pH.
measurement of free inorganic chlorine at constant pH