EU R32 Aqua Falcon Inverter Air Cooled Chiller
SuperiorPerformance
InverterWaterPump
O Voltage Protection
2 Communicaiton
Overload Protection
寳 Phases Loss Protection
Short-circuit Protection
Overheat Protection
High Efficiency
Energyefficiencyclassup to \mathsf { A } { + } { + } { + } complyingwith the European ERP requirements.
Wide Operation
-20°C Cooling
The fan's logic control system isoptimized for stable single-fan operation at an ultra-low temperature of - 2 0 ^ { \circ } C This enhancement ensures the modularchileroperateswith enhanced stability,significantlyreducing start-stop cyclesand improving overall operational efficiency.
Stable&Reliable
Multiple Certifications
Designed specifically forthe Europeanmarket,thisunit meetsallrelevantEUcertificationstandards.
Enclosed Electrical Box
Protects internal components from external environmental factorsand ensures long-term product durability.
Sands Protection
Moisture Protection
Mosquitoes Protection
Rain&Snows Protection
Low Noise Design
Anti-clogging
Equipped with filterand provided with water qualityguidelines,ensuring stableand eficient systemoperation.
Filter
Water Quality
When wellor river water is used as chilled water,it can lead to significant sediment accumulation,such as limescaleand sanddeposits.Therefore,well wateror river water must befilteredand softened usinga water softening device before being supplied to the water system.If sand and clay setle in the evaporator,they mayblock chilled watercirculation,causing theevaporator to freeze.If thehardnessof thechilledwater is exceively high,limescale buildupis ikely tooccur,whichmayresult inequipment corrosion.Therefore,the qualityof the chiled water should be analyzed beforeuse,including parameters suchaspHvalue,conductivity, chloride ion concentration,and sulfate ion concentration.
I Smart Running
Thesystemfeaturesautomaticload distribution,reducing high-loadoperationandcutting totalpowerconsumption.
■Rotating Operation
Intelligentsequentialoperationbalances theoperating hoursofallsystemsand modules,extendingservicelife and enhancingreliability.
IBackup Operation
In theevent of a system fault,thebackup operation function automaticallyactivates redundant systems, ensuringuninterrupted operation forend users.
DustRemoval
Fully protected against summer dust accumulation,theunitautomatically initiatesitsdustremoval functionto maintain high-efficiency heatexchange, ensuringstable,reliable,andworry-free operationatalltimes.
11-layerAnti-freezeProtection
Multiple layers of anti-freezing protection eliminate concerns about water system freezing.
1SmartDefrost
Advanced intelligent defrost control minimizes the impact on the entire system.
Snow-blowing
Fullyprotected againstwinter snow accumulation,theunitautomatically initiatesitssnowremoval function to maintain high-efficiency heatexchange, ensuringstable,reliable,andworry-free operationoftheentiresystematalltimes.
ITemperatureCurve
High flexibility丨Eliminates the need for frequent target temperature adjustments.
ISmartTimer
Operating modes can be pre-set on dailyand weekly schedules,enabling automatic switching between Turbo, Standard and ECO modes to meet user comfort and energy efficiency requirements.
I Cascade Max.16 Units
Modulardesign, flexiblecombinationmoreconvenient fordesignand installation.
VariableControls
Themodularchillercanbeconnected to thermostats (Coolingand Heating),remote control signals,and fire alarm signals,enablingmore intelligent operation.
Modbus
Modbus port pins are pre-reserved on the PCB, ensuring full compatibility with RS485 communication protocols.
USB Commisioning
Following initial chiller configuration fora project, parameters can be copied toa USB flash drive. These parameters can thenbe quickly imported and applied to subsequent similar projects via USB, significantly improving installation efficiency.
APP Control
OTA Upgrade
Engineerscancompletefirmwareupdates,parameter adjustments,and fault repairsremotelyviathecloud without needing to be on-site,significantly reducing travel and labor costs.
USB Upgrade
In the absence of internet, the system supports USB one-clickinsertionforupdates,ensuringseamless operation with minimal manual intervention.
PowerLimitation
This power limiting function is designed to accommodate gridvoltage fluctuations inspecific regions,ensuringstableanduninterruptedoperation for commercial applications.
80kw
70kw
60kw
50kw
40kw
30kw
20kw
10kw
Okw
6 12 18 24Time
I IOTPlatform
Real-time operation datamonitoringandanalysis; Remote equipment health assessment and potential faultdetection; Improved module reliabilityand operational stability.
Easy Maintenance
Hydraulic Kit
Without Hydraulic Kit
·Lowerweight for transportation ·Easier formaintenance
WithHydraulic Kit
·Lowerinstallation cost ·Shorter debugging time
Pipe Clamp
All water pipesare connected via quick-release pipeclamps,enablingfast,tool-freereplacement and assembly.
IUltimatelnstallationDistance
Thanks to optimized design of the air ducts, fan bladesand condenser,theminimum installation clearanceis reduced to 6 0 0 ~ \mathsf {mm }
1RotatedE-box
Theupper section of the electrical enclosure features a rotatable design,allowing quick and easy access to internal components forsimplifiedmaintenance.