Hisense Household Energy Storage System
Group Diversity-Tolerant Unlimited Trustiness
Founded in 1969, Hisense has always adhered to the development strategy of "Develop enter-prise with technologies & Operate in a steady way”. The Group has five listed companies including Hisense Visual Technology (600060), Hisense Home Appliances(000921), Sanden Holdings (6444), Kelin Electric (603050),and Changelight (300102). It owns more than 20 subsidiaries, and many brands including Hisense, Toshiba TV, GORENJE, KELON, Ronshen, ASKO and VIDDA, etc. As a benchmark company to undertake Hisense Group's development strategy in the fields of power electronics and new energy, Qingdao Hisense Network Energy Co., Ltd. is currently mainly engaged in the R&D and sales of related products in the field of new energy, and has created full-stack solutions in the fields of light, storage and charge, with a cumulative energy storage supporting business of 10G watt-hours.
Sales revenue in 2024 RMB 215.3 billion
31 R&D organizations
64 overseas branches
36 industrial parks and production bases
100,000 employees
Hisense Network Energy
A leading global provider of comprehensive new energy solutions
Adhere to Hisense's development strategy of "Develop enterprise with technologies", rely on power electronics technology and green temperature control technology, promote the green energy revolution, and provide strong support for the carbon peaking and carbon neutrality goals.
Qualification of Products
Ou product obtaine man certifications, includin IEC 6 2 6 1 9 : 2 0 2 2 , I E C / E N 6 1 0 0 0 - 6 - 1 : 2 0 1 9 , I E C / E N 61000-6-3:2021, IEC/EN 62109-1/-2, IEC/EN 62477-1, I E C / E N 6 1 0 0 0 - 6 - 1 / - 6 - 3 , E N / I E C 6 1 0 0 0 - 3 - 1 1 , EN61000-3-12, UN38.3.Certificates for European Grid Connection: EN50549-1, Certifica tes for German Grid Connection: VDE4105/0124, Certificates for Italian Grid Connection: CEI 0-21:2022, Certificates for Dutch Grid Connection: EN50549 -1, Certificates forBelgian Grid Connection: C10/11, G98 etc.
Energy Storage System
Provide a household energy storage system solution with convenient installation.
Entered European markets such as Italy and Germany
Temperature Control of Energy Storage
Provide a household energy storage system solution with convenient installation.
Accumulated installed capacity of energy storage facilities 25GWh
Temperature Control System of Special-Purpose Air Conditioners
Provide green, efficient, intelligent and safe special - environment temperature - control solutions
In the four major operator systems including China Mobile, China Unicom, China Telecom, and China Tower, the communication temperature - control products rank TOP1 in terms of proportion.
Product Value
Hisense Household Energy Storage System, providing one-stop solutions for home energy problems to maximize your usage of electricity.
Intelligent peak-valley electricity utilization Save electricity costs
Power market transactions Add extra revenues
Intelligent PV-ES
Cloud monitoring
Realize self-generation and self-consumption via PV system, and surplus electricity is uploaded to the grid or stored in household energy storage batteries.
Support uploading system data to the cloud through Wi-Fi, etc., and monitoring information through mobile apps, platforms, etc.
Stable power consumption
Daily electricity consumption can be set with power priority, and the inverter, combined with household energy storage batteries, achieves stable electricity consumption in all scenarios of household loads.
Load consumption
A new mode of household electricity consumption is created through green electricity usage terminals and household loads, such as household appliances and electric vehicles.
Hi-Mini Household Energy Storage Solution
Hi-Mini can be used in combination with renewable energy sources such as solar photovoltaic panels or wind turbines, converting solar and wind energy into DC electric energy to be stored in batteries and then converting into AC electricity for home use when needed. With its features of safety, high-efficiency, intelligence, and convenience, Hi-Mini enables users to enjoy a high -quality power supply with peace of mind, while also experiencing unprecedented convenience and security.
Hi-Mini household energy storage solution is a miniaturized energy storage offering independently developed by our company. It includes a single-phase low-voltage split system and a three-phase high-voltage split system. The single-phase low-voltage split-type system is made up of a single-phase hybrid inverter paired with a low-voltage battery system. Meanwhile, the three-phase high-voltage split-type system consists of a three-phase hybrid inverter integrated with a high-voltage battery system.
Energy in hand, light on command
Easy installation
Lightweight and compact, easy to install, save 50% of labor installation costs
Intelligent O&M
Mobile phone (Wi-Fi) setting and maintenance available
High cost-effectiveness
Enhance full load efficiency by 0.5% , and significantly improve cost effectiveness
High Compatibility
The high-power can cover 3\~8 kW, meeting the single-phase load needs of users
Single Phase Inverter
| Model | HiRY3KS-A0 HiRY3K6S-AO HiRY4KS-A0 HiRY4K6S-AO HiRY5KS-AO| HiRY6KS-A0 | |||||
| Input parameters (Photovoltaic) | ||||||
| Maximum input power (kW) | 4.5 | 5.4 | 6.9 | 12 | ||
| Starting Voltage (kW) | ||||||
| Maximum DC voltage (V) | 550 | |||||
| MPPT working voltage range/rated voltage (V) | 80~500*/360 | |||||
| Maximum input currentof a single MPPT (A) | 16/16 16/16 | |||||
| 16/16 | 16/16 Output parameters (AC) | 16/16 | 16/16 | 16/32 | ||
| Rated power (kW) | 3.68 | 4.6 | 5 | 6 | 8 | |
| Maximum output current (A) | 14.3 16 | |||||
| Grid voltage/range (V) | 19.1 20 21.7 230/176~270 | |||||
| Grid frequency (Hz) | ||||||
| Power factor | 50/60 1 (0.8lead to 0.8lag) | |||||
| Current THDI | ||||||
| Grid connection type | ||||||
| Batteryparameters | L+N+PE | |||||
| Battery voltage range (V) | 40~58 | |||||
| Maximum charging voltage (V) | ||||||
| Maximum charging/discharging current (A) | 60/60 72/72 80/80 | |||||
| Type | Lithium batteries/lead-acid batteries | |||||
| Communication mode | CAN | |||||
| 3 | ||||||
| Rated power (kW) | 3.68 | Emergency power output (EPS) 4.6 | 8 | |||
| Rated output voltage (V) | 4 | |||||
| 13 | 16 | 230 | 20 21.7 | 26 | 35 | |
| Rated output current(A) | ||||||
| Rated output frequency (Hz) | 50/60 | |||||
| Automatic switching time (ms) | ||||||
| THDu | ||||||
| Overload capacity | 110%, 60S/120%, 30S/150%,722ms | |||||
| General | ||||||
| Battery charging anddischarging effcieny | 96% | |||||
| Maximum eficiency | 98% | |||||
| European fficiency | 97% | |||||
| MPPT efficiency | 99.9% | |||||
| Protection class | IP65 | |||||
| Noise (dB) | ||||||
| Environmental temperature range (°℃) | -25~60 | |||||
| Cooling method | Natural cooling | |||||
| Relative humidity | 0~95% (No condensation) | |||||
| Altitude (m) | 0~2000 (No derating below 2000) | |||||
| Dimensions (W*D*H, mm) | 454.5*200*467 | |||||
| Netweight (kg) | 19 | |||||
| Topology | No isolation transformer | |||||
| Night standby power consumption (W) | ||||||
| Display | No screen | |||||
| Communication mode | RS485/CAN/Wi-Fi | |||||
IP65 Protection
High IP grade; No worry for water immersion;
Supporting outdoor placement.
High Security
It is equipped with multiple protection measures, such as intrinsic safetyof battery, module technology, housing protection, circuit protection, and supporting fire protection.
Easy to Use
It can bewoken up and turned on and off with one click, which can improve user experience.
Modular Stacked Design
It adopts stacked installation, which is simple and convenient, and allows upto 3 battery packs to be used in parallel.
Efficient Filtering
It adopts the Kalman filtering algorithm, which provides more accurate SOC estimation in the long time domain and extends its service life.
Multi level security
Equipped with aerosol fire extinguishing device.
Good low temperature performance
Equipped with a heating film, which can be first used in cold areas.
Plug-and-play
If a single battery module fails, itwill automatically exit without affecting system usage;
after faultre covery, the module automatically connects tothe system.
Key data display
4.3-inch display screen displays key data of voltage, current, SOC,and current status.
Low - Voltage Battery System
| Product model | HEL5-B0 | HEL10-B0 | HEL15-B0 |
| Cell specification | 100Ah,LFP | ||
| Number of modules (Pcs) | 1 | 2 | 3 |
| Maximum available power (kw) | 2.5 | 5 | 5 |
| Rated capacity (kWh) | 5.12 | 10.24 | 15.36 |
| Rated voltage (Vdc) | 51.2 | ||
| Maximum current (A) | 50 100 | ||
| Working ambient temperature (°℃) | Charge: 0~55; Discharge: -20~55 | ||
| Communication mode | CAN/RS485 | ||
| Dimensions (W*D*H, mm) | 685*155*565 | 685*155*925 | 685*155*1290 |
| Weight (kg) | ~58 | ~105 | ~152 |
| Protection class | IP65 | ||
| Cooling method | Natural cooling | ||
| Cyclelife (Times) | 6000 (70%EOL) | ||
| Display | 4.3-inch display (SOC, voltage, current, operation status) | ||
| Mounting method | Floor-standing type | ||
| Installation environment Indoor/outdoor | Indoor/outdoor | ||
| Applicable inverter | Only support Hisense inverters | ||
| Altitude (m) | ≤2000 | ||
| Qualification | UN38.3、IEC62619、IEC61000 | ||
Support the connection of diesel generators; Support full-power discharge and automatic management of battery charging and discharging; Adopt a non-external cooling fan design to reduce noise.
Economical and Practical
Support multiple operating modes, making it more economical;
Serve as UPS to support critical load when there is no grid power supply.
Safety and Reliability
Have the functions of anti-islanding protection, photovoltaic input reverse protection, battery input reverse protection, insulation monitoring, residual current monitoring, AC overcurrent protection, AC overload protection, and short circuit protection.
| Protection class | |||||
| Working temperature range (°C) | |||||
| Relative humidity | 0~100% 4000 Derating above 2000) | ||||
| Altitude (m) | |||||
| Dimensions (W*D*H, mm) | |||||
| Net weight (kg) | 30 | 31 | 596*566*220 33 | 34 | |
| Cooling method Noise (dB) | Natural cooling ≤35 | ||||
| Night standby power consumption (W) | |||||
| EMC | |||||
| Safety standard | |||||
| Display BMS Interface | |||||
| EMS interface/meter communication interface | |||||
| Communication interface supported | |||||
| Maximum charging & discharging power (kW) | 6.6 | 8.8 | Battery interface parameters 13.2 | 16.5 | |
| Battery voltage range (V) | |||||
| Battery operating voltage range (V) | 150~550 50 | ||||
| Maximum charging/discharging current (A) | |||||
| Rated charging/discharging current (A) | |||||
| Lithium battery and lead-acid battery | |||||
| CAN | |||||
| Input parameters (DC) 15 | |||||
| Maximum DC input power (kW) Maximum DC input voltage (V) | 9 | 12 1000 | 18 | 22.5 | |
| MPPT voltage range (V) | 250~850 | 180~850 330~850 430~850 | 620~850 | ||
| MPPT full-load voltage range (V) | |||||
| Minimum input voltage/starting voltage (V) | 510~850 | ||||
| Maximum input current of a single MPPT (A) | 18/18 | 18/18 | 18/18 25/25 | 20/20 | |
| Maximum shortcircuit current (A) | 25/25 | 25/25 | 18/18 25/25 | 30/30 | |
| Numberof MPPT trackers | |||||
| Numberof strings per MPPT tracker | 1/1 | 1/1 | 2 1/1 700 | 2/2 | |
| Rated inputvoltage (V) | |||||
| AC-side (Grid connection) parameters 10 | |||||
| Rated output power (kVA) | 6 | 8 | 15 | ||
| Maximum output power (kVA) | 6.6 | 8.8 | 13.2 26.4 | 16.5 | |
| Maximum grid input power (kVA) | 13.2 | 17.6 | 33 47.6 | ||
| Maximum grid input current (A) | 19.1 | 25.5 | 31.8 | ||
| Rated output current (A) | 8.7 | 11.5 | 14.4 | ||
| Maximum output current (A) | 9.5 | 12.7 | 15.9 | ||
| Rated grid voltage (V) | 19.1 380/400, 3W+N+PE | 23.8 | |||
| Rated grid frequency (Hz) 50/60 | |||||
| AC-side (Off-grid) parameters 10 | |||||
| Rated outputpower (kVA) | 6 | 8 | 12 13.2 | 15 | |
| Maximum output rated power (kVA) | 8.8 | 8.8 | 17.3 | 16.5 | |
| Maximum output rated power (kVA) | 8.7 | 11.5 | 21.7 | ||
| Maximum output current (A) | 9.5 | 12.7 | 23.8 | ||
| Rated output voltage (V) | |||||
| Rated output frequency (Hz) | |||||
| THDu | 97.9% | 98.2% | 97.6% | ||
| Maximum efficiency European efficiency | 97.2% | 97.9% 97.2% | 97.5% | 97.8% | |
| MPPT effciency | 97.5% | ||||
| Maximum battery charging/discharging effciency | 97.5% | 97.5% | 99.9% 97.5% 97.6% | 97.8% | |
IP65 Protection
IP65 protection It features high IP rating, and it is waterproof and dustproof.
High Security
It is equipped with multiple protection measures such as intrinsic safety of battery, module technology, housing protection, circuit protection, and supporting fire protection, etc.
Easy to Use
It can bewoken up, and turned on and off with one click, which can improve user experience.
Modular Stacked Design
It adopts a stacked installation, which is simple and convenient,supporting up to 8 battery packs in series, with a capacity of up to 20 kWh. With the additional parallel interface, it supports 5 energy storage systems for parallel use, with a maximum capacityof up to 100 kWh, and supports 8-meter battery packs with a series capacity of up to 100 kWh.
Efficient Filtering
It adopts the Kalman filtering algorithm, which provides more accurate SOC estimation in the long time domain and extends its service life.
High-voltage Battery System
| Model | HEH10-B0 | HEH12.5-B0 | HEH15-B0 | HEH17.5-B0 | HEH20-B0 |
| Cell specification | 50Ah, LFP | ||||
| Number of modules | 4 | 5 | 6 | 7 | 8 |
| Battery capacity (kWh) | 10.24 | 12.8 | 15.36 | 17.92 | 20.48 |
| Rated voltage (Vdc) | 204.8 | 256 | 307.2 | 358.4 | 409.6 |
| Rated current (A) | 25 | ||||
| Usage temperature (°C) | Charge: 0~55 Discharge: -20~55 | ||||
| Communication mode | CAN/RS485 | ||||
| Dimensions (W*D*H, mm) | 560*340*800 | 560*340*940 | 560*340*1075 | 560*340*1210 | 560*340*1350 |
| Weight (kg) | ~155.5 | ~189.5 | ~223.5 | ~257.5 | ~291.5 |
| Protection class | IP65 | ||||
| Cooling method | Natural cooling | ||||
| Cycle life | 6000 (70%EOL) | ||||
| Display | 4.3-inch display (SOC, voltage, current, operation status) | ||||
| Mounting method | Floor-standing type | ||||
| Use environment | Indoor/outdoor | ||||
| Applicable inverter | Only support Hisense inverters | ||||
| Altitude (m) | ≤2000 | ||||
| Qualification | Un38..3、IEC61000、IEC62619、IEC62477 | ||||
Hi-Prime Household Energy Storage Solution
Hi-Prime household energy storage solution is independently developed by our company. It is an integrated residential energy storage system meticulously crafted for modern home energy management.It encompasses a single-phase low-voltage all-in-one machine and a three-phase high- voltage all-in-one machine. The single-phase low-voltage all-in-one machine is equipped with a hybrid inverter with a power range of 3kW-6kW, along with expandable battery modules. The three-phase high-voltage all-in-one machine comes with a hybrid inverter having a power range of 5kW-12kW, paired with expandable battery modules. With its excellent cost-effectiveness, pared-down simplicity, extreme convenience, impregnable safety, and state-of-the-art intelligence, HiPrime has become the go-to choice for modern home energy management.
Simple and safe power, lighting our smart life
Simple Installation
All in one design, plug and play, expandable and the installation can be completed in less than 25 minutes.
□
Sleek Design
Designed with minimalist aesthetics, it suits indoor and outdoor use. A touch-screen LCD display allows for easy status checks.
Simple O&M (Operation and Maintenance)
Monitor device status in real-time via the APP. It alerts for anomalies and offers smart maintenance.
Ultimate Safety
IP65 protection level, five-layer safety design, strict standards, and extreme-condition testing ensure overall reliability.
Super Intelligence
Multiple scenario modes. Control energy status with one tap. Customize exclusive energy strategies.
Three Phase High Voltage Integrated Machine
| Type | HiRY5KT-AA1 | HiRY6KT-AA1 | HiRY8KT-AA1 | HiRY10KT-AA1 | HiRY12KT-AA1 | |
| Input PV | 15 | |||||
| Maximum PV input power (kW) | 7.5 9 | |||||
| Maximum DC voltage (V) | 1000 | |||||
| Starting voltage (V) | ||||||
| MPPT working voltage range (V) | 140~900 | |||||
| Number of MPPT | 2 | |||||
| Number of MPPT strings per channel | 1 | |||||
| Maximum input current per MPPT channel (A) | 18 | |||||
| Maximum short-circuit current per MPPT channel (A) | 25 | |||||
| Input AC | ||||||
| Max. AC apparent power (kVA) | 11 | 13.2 | 17.6 | 22 | 26.4 | |
| Max. AC current (A) | 16 | 19.2 | 25.4 | 31.8 | 38.2 | |
| 50/60 | ||||||
| Output AC (On-Grid) | ||||||
| Rated power (kW) | 5 | 6 | 8 | 10 | 12 | |
| Maximum apparent power (kVA) | 5.5 | 6.6 | 8.8 | 11 | 13.2 | |
| Rated voltage (V) | ||||||
| Rated frequency (Hz) | 400 (339~438) 50/60 (45-55/55-65) | |||||
| Rated output current (A) | 7.2 | 8.7 | 11.6 | 14.5 | 17.4 | |
| Maximum output current (A) | 8.0 | 9.6 | 12.7 | 15.9 | 19.1 | |
| THDi | ||||||
| Grid connection type | ||||||
| 3W+N+PE Output AC (Backup) | ||||||
| Rated power (kW) | 5 | 6 | 8 | 10 | 12 | |
| Maximum apparent power (kVA) | 5.5 | 6.6 | 8.8 | 11 | 13.2 | |
| Rated output current (A) | 7.2 | 8.7 | 11.6 | 14.5 | 17.4 | |
| Maximum output current (A) | 8.0 | 9.6 | 12.7 | 15.9 | 19.1 | |
| Overload Capability | >150% for 10 sec | |||||
| Output Current Harmonic Distortion | THD | |||||
| Transfer Time (ms) | ||||||
| Battery | ||||||
| Maximum charging and discharging power (kW) | 5 | 6 | 8 | 10 | 12 | |
| Battery voltage range (V) | 120~800 | |||||
| Maximum charging and discharging current (A) | 30 | |||||
| Rated charging and discharging current (A) | 25 | |||||
| Battery type | Lithium | |||||
| Scalability (kWh) | 5.12 (2~6 in series) | |||||
| Cycle life Weight (kg) | >6000 | |||||
| Dimensions (W*D*H, mm) | Base+Combiner Box: 15 Battery pack: 50 | |||||
| Battery pack: 730×200×320 Combiner Box: 730*200*170 Base:730*200*60 | ||||||
| Warranty (Years) | 5 | |||||
| Safety | CE, TUV (IEC62619), RoHS, REACH | |||||
Three Phase High Voltage Integrated Machine
| Type | HiRY5KT-AA1 | HiRY6KT-AA1 | HiRY8KT-AA1 | HiRY10KT-AA1 | HiRY12KT-AA1 | |
| General Data (Inverters) | ||||||
| Dimensions (W*D*H, mm) | 730*200*495 | |||||
| Weight (kg) | ||||||
| Working temperature range (C) | -25~60 (Derating 45) | |||||
| Cooling method | Natural cooling | |||||
| Protection level | IP65 | |||||
| Relative humidity | 0-95% | |||||
| Altude(m) | 3000 (Derating by 2000) | |||||
| DC connection type | MC4 | |||||
| AC connection type | Connector | |||||
| Display mode | LED/LCD | |||||
| communication interface | RS485/CAN/USB | |||||
| Noise (dB) | 35 | |||||
| Overvoltage category | OVC III(AC Main), OVC II (PV) | |||||
| Efficiency 97.5% | ||||||
| Maximum efficiency | 97.5% | 97.5% | 97.0% | 98.0% | 98.0% | |
| Efficiency in Europe | 97.0% | 97.0% | 97.5% | 97.5% | ||
| MPPT eficiency | 99.9% | 99.9% | 99.9% | 99.9% | 99.9% | |
| Protection | ||||||
| Input reverse connection protection | Yes | |||||
| Battery reverse connection protection | No | |||||
| PV overvoltage protection | Yes | |||||
| Ant islanding protection | Yes | |||||
| Insulation impedance testing | Yes | |||||
| Residual current detection | Yes | |||||
| AC short circuit protection | Yes | |||||
| AC overcurrent protection | Yes | |||||
| AC overvoltage protection | Yes | |||||
| Output overvoltage protection | Yes | |||||
| PV input DC switch | Yes | |||||
| Battery soft start protection | No | |||||
| Lightning protection | Yes | |||||
| Remote scheduling of dry nodes | Yes | |||||
| Prevent reverse flow | Yes | |||||
Tactical Scenario
Simple Installation
All in one design, plug and play, expandable and the installation can be completed in less than 25 minutes.
□
Sleek Design
Designed with minimalist aesthetics, it suits indoor and outdoor use. A touch-screen LCD display allows for easy status checks.
Simple O&M (Operation and Maintenance)
Monitor device status in real-time via the APP. It alerts for anomalies and offers smart maintenance.
Ultimate Safety
IP65 protection level, five-layer safety design, strict standards, and extreme-condition testing ensure overall reliability.
Super Intelligence
Multiple scenario modes. Control energy status with one tap. Customize exclusive energy strategies.
Single Phase Low Voltage Integrated Machine
| Type | HiRY3KS-A1|HiRY3K6S-A1 HiRY4KS-A1|HiRY4K6S-A1 HiRY5KS-A1 | |||||
| Input PV | ||||||
| Maximum PV input power (kW) | 4.5 | 6 | 6.9 | 9 | ||
| Maximum DC voltage (V) | 5.4 | |||||
| Start-up voltage (V) | 550 40 | |||||
| MPPT working voltage range (V) | ||||||
| Number of MPPT | 1 | 2 | ||||
| Number of MPPT strings per channel | 1 | |||||
| Maximum input current per MPPT channel (A) | ||||||
| Maximum short-circuit current per MPPT channel (A) | ||||||
| 22.5 Input AC | ||||||
| Normal AC Voltage (VAC) | 220/230 (single phase) | |||||
| Frequency (Hz) | ||||||
| Max. cont. input (A) | 27.3 | 32.7 | 36.4 | 41.8 | 45.5 | 54.5 |
| Max. cont. input (kW) | 6 | 7.2 | 8 | 9.2 | 10 | 12 |
| Grid type | L+N+PE | |||||
| Rated power (kW) | 3 | 3.6 | 4 | Output AC (Backup) 4.6 | 5 | 6 |
| Maximum apparent power (kVA) | 3.3 | 4 | 4.4 | 5.1 | 5.5 | 6.6 |
| Rated voltage (V) | 220/230 | |||||
| Rated frequency (Hz) | ||||||
| Rated output current (A) | 18 | 50/60 (45-55/55-65) 20 | 22 | 25 | 30 | |
| Maximum output current (A) | 15 16.5 | 19.8 | 22 | 24.2 | 27.5 | 33 |
| THDi | ||||||
| Grid connection type | ||||||
| L+N+PE Output AC (Off-Grid) | ||||||
| Normal Voltage (VAC) | 220/230 (single phase) | |||||
| Frequency (Hz) | ||||||
| Nominal Current (A) | 15 | 18.2 | 50/60 20 | 23.2 | 25 | 30 |
| Max. cont. Power (kW) | 3 | 3.6 | 4 | 4.6 | 5 | 6 |
| Overload Capability(off grid) | >200% for 15 sec | |||||
| Output Power Factor (off grid) | ||||||
| Output Current Harmonic Distortion | 1.0 THD | |||||
| Battery | ||||||
| Maximum charging and discharging power (kw) | ||||||
| 3.3 | 3.6 4 | 48 (40-60) | 4.6 | 5 | 6 | |
| Battery voltage range (V) | ||||||
| Maximum charging and discharging current (A) | 75 | 90 100 | 110 | 120 | 120 | |
Single Phase Low Voltage Integrated Machine
| Type HiRY3KS-A1| HiRY3K6S-A1 | HiRY4KS-A1 HiRY4K6S-A1 HiRY5KS-A1 HiRY6KS-A1 | |||||
| Rated charging and discharging current (A) | 120 | |||||
| Battery type | Li-ion | |||||
| Capacity (kWh) | 5.12 | |||||
| Max number of parallel (PCS) | 4 | |||||
| Cycle life | >6000 | |||||
| Weight (kg) | Base+Combiner Box: 13 Battery pack: 48 | |||||
| Dimensions (W*D*H, mm) | Battery pack: 600*200*370 Combiner Box:600*200*200 Base: 600*200*60 | |||||
| Dimensions (W*D*H, mm) | General Data (Inverters) | |||||
| Weight (kg) | 600*200*470 | |||||
| Working temperature range (℃) | ≤23 | |||||
| Cooling method | -25~60 (Derating 45) Natural cooling | |||||
| Protection level | IP65 | |||||
| Relative humidity | ||||||
| Altitude (m) | 0-95% 3000 (Derating by 2000) | |||||
| DC connection type | MC4 | |||||
| AC connection type | Connector | |||||
| Display mode | LED/LCD | |||||
| communication interface | RS485/CAN/USB | |||||
| Noise (dB) | 35 | |||||
| Overvoltage category | OVCII(AC Main), OVC II(PV) | |||||
| Efficiency | ||||||
| Maximum efficiency | 97.5% | 97.5% | 97.5% | 97.5% | 98.0% | 98.0% |
| Efficiency in Europe | 97.0% | 97.0% | 97.0% | 97.0% | 97.5% | 97.5% |
| MPPT eficiency | 99.9% | 99.9% | 99.9% | 99.9% | 99.9% | 99.9% |
| Protection | ||||||
| AC Output Overcurrent Protection | Yes | |||||
| AC Output Overvoltage Protection | Yes | |||||
| AC Output Short Circuit Protection | Yes | |||||
| Thermal Protection | Yes | |||||
| DC Terminal Insulation Impedance Monitoing | Yes | |||||
| DC Component Monitoring | Yes | |||||
| Ground Fault Current Monitoring | Yes | |||||
| Power Network Monitoring | Yes | |||||
| Island Protection Monitoring | Yes | |||||
| Earth Fault Detection | Yes | |||||
| Overvoltage Load Drop Protection | Yes | |||||
| Residual Current (RCD) Detection | Yes | |||||
Tactical Scenario