H.Stars Modular Chiller/Heat Pump
·Air-cooledmodularunit
·Air-cooled heat pumpmodule
·Lowambient temperatureairsource (hotwater) module
·Combined cooling,heatand power (trigeneration)module
Special voltagemodule (optional)
Modelandspecifications
-Water-cooled modularunit ·Water source heat pump module ·Lowambient temperatureairsource heat pump module
·Heat recovery module (optional) ·VSD module (optional)
The modular unit adopts modular control technology,whichcombinesmultipleindividual unitsintoonecombinationforoverallcontrol.The combination operates with multiple slave units beingcontrolledbya masterunit;operationof multiple individual units can be centrallymonitored andcontrolledononecontrolscreen;anditisalso possible that eachunitoperates independently.
Smart operation
Witheach individual unit beingindependent withitsownrefrigerantandwatercircuits,the overalloperatingloadofthemodularunitcanbe controlledbyadjustingthenumberof individual unitsworkingtogether;andfailureofanyone individual unit will notaffect the normal operation of other individual units.
Automatic control
Itsmicrocomputercontrol system is easyto operate,withvarious protectionand intelligent loadcontrol functions.Themodularunit provides multiple protections forcompressor,fan,water flow rate,highand lowpressureof therefrigeration system,watertemperature,andpowersupply, etc.And it is optional to use Siemens PLC controllertorealizeModBusRTU,TCPorOPC communication.
High-performancecomponents
High-performance components The modular unit uses high-efficiency heat exchangers, low-energy fans,and brand-name compressors.Watersystem accessories such as pumpsand filters canalso be integratedaccording to customerrequirements.
Complete product range
Thereare10seriesofproductsavailabletoselect from to suit needs of different projects,including air-cooling modules,water-cooling modules, lowambienttemperatureairsourcemodules, cold water modules,heat pump modules,and trigenerationmodules.
Non-standard products
Besides standard specifications,various non-standard units can also be available by customization.
Product categories (Air-cooled series)
Low ambient temperature module air source hot water
Lowambient temperature module air source hot water is designed to be used to provide heating in winter in extremelycold regions.One modularunit canconsistof as manyas8individual units.Individual unit's heating capacity range:15kW-55kW;and ambient temperature range: - 2 5 9 0 - 3 5 9 0 :
Lowambient temperature module air source heat pump
Lowambient temperaturemodule air source hot water is designed to be used to provide heating in winterand cooling in summerincold northern regions.One modularunitcanconsistofas manyas8individualunits.Individual unit's heating capacity range:15kW-55kW;cooling capacityrange:20kW-80kW;and ambient temperaturerange: -25℃ { ~ } 4 3 ^ { \circ } { C } :
Air-cooled modular unit
Lowambient temperature module air source hot water is designed to be used to Air-cooled modularunit can providecooling in summerwithoutthe need of cooling towerand machine room;and is suitableforprojects that have insuffcient watersupply or lack machine room.One modular unit can consist of as many as8 individual units.Individual unit's cooling capacity range: 6okW-16okW;chilled water temperature range: 5 ^ { \circ } { C } (20 { ~ } 2 0 ^ { \circ } { C } ;ambient temperature range: 1 5 ^ { \circ } C ~ 4 3 ^ { \circ } C :
Air-cooled module heat pump
Air-cooled module heat pumpcan provide cooling in summerand heating in winter without the need of cooling towerandmachine room;and issuitable forprojects that have insufficient watersupplyorlack machine room.One modularunit can consist of as manyas 8 individualunits.Individualunit's coling capacityrange:6OkW-160kW; heating capacity range:7OkW-17okW;chilled water temperature range: 5 ^ { \circ } { C } (20 { ~ } 2 0 ^ { \circ } { C } ;hot water temperature range: 3 5 { ^ \circ C } { ~ } 5 0 ^ { \circ } { C } :
Module combined cooling, heat and power (trigeneration)
Combined cooling,heatand power(trigeneration) module ofers five functions to providecooling,heating,hot water,hotandcoldwaterandheatingandhotwater;sutableforhotels,villas,hospitals,schoolsandotherplaces thathave cooling and heat demand.Onemodularunit can consistof as manyas 8individualunits.Individual unit's cooling capacity range:60kW-160kW;heating capacityrange:70kW-240kW;chiled water temperaturerange: 5 { ^ \circ C } (204号 { ~ } 2 0 ^ { \circ } { C } ;hot water temperature range: 3 5 ^ { \circ } { C } (204号 { ~ } 5 0 ^ { \circ } { C } :
System schematic of module air-cooled unit
Water-cooledmodularchiller
Water-cooled modularchiller,when completed with cooling tower,can providecooling in summer;and itcan consist of as manyas 8individual units.Cooling capacity range:70kW-180kW;chilled water temperature range: 5 % (204号 { ~ } 2 0 % ;cooled water temperature range: 1 5 ^ { \circ } \mathsf { C } ~ 4 0 ^ { \circ } \mathsf { C } ·
Water source module heat pump
Watersource module heat pump,whichcanbe used to provide cooling in summerand heating inwinter,is high inenergyeffciencyand is suitable for projects that have sufficient watersupplyoraccessto ground water.One modularunitcanconsistofasmanyas8individualunits.Cooing capacityrange:7OkW\~-2ookW;heatingcapacity range:90kW-230kW;chilledwater temperature range: 5 % (204号 { ~ } 2 0 % ;Max.hotwater temperature: 5 0 ^ { \circ } \mathsf { C } :
Water-cooled module cooling system
Smartmicro-processor control
The unit record during its operation the running time of compressors,sothatthecompressorscanbestarted andstoppedinadynamicalwayinresponseto the start and stop of the unit,as well as to the loading andunloading of operating load,which helps to balance operationand wearamong the compressors. Multiple levelsofpasswordprotectionareinplace for theprotectionof parametersatall levels.Adjustable multiple timing:one-off timing,weekly timed switching on/off,weekly timing seting,and holiday setting.
Heat exchangers are available in a varietyofmaterials
Heatexchangerisamain keycomponentof theair conditioning unit,the manufacturing technology of whichwill have direct effects on product quality.As the only part of the unit that is in contact with outside air,heatexchangetubesarecloselyrelatedtothe service lifeof the unit.The thicknessandmaterial of heat exchange tubes are of critical importance, and customersmay choose the right kind of tube according toairand waterquality of thesiteofuse.
Flexibleand easycombination
Upto 16 modulescanbeconnectedtogether,which offerswiderrangeofcapacityadjustment.Modular unitmeanseasierandmore flexible transportation andinstallation.Itcanbe placedinvariousplacesof relatively small usable space,saving valuable building space.Italsomakescapacityexpansioneasier,and installment investment possible.
Complete range of functions
Themodular unit series,offering for selection various typesofunits,includingair-cooled modularchillers, air-source heat pump modularunits,lowambient temperature hotwatermodularunits,water-cooled modularchillers,andwater-sourceheatpumpmodular units,stands to satisfy most application needs.
Stableand reliable operation
Thereare multiple independent refrigerant systems in eachmodule of the unit, therefore even when some ofthesesystems giveoffalarmandstopoperation,it will not affect the operationof other circuits,and the failure ofa modulewill notaffect the operation of other modules.
Various additional upgrade options are available
VSD models,heat recoverymodels,low ambient temperaturemodels,combined cooling,heatand power(trigeneration)models,special voltagemodels, andauxiliaryelectricheatersareavailabletomeetthe individual needs of different users.
High efficiencyand energy saving
The unit's brand compressors and expansion valves,aswellas self-produced high-eficiency heat exchangers,help toachieve highenergyefficiency and lownoise level,making theoperationquieterand moreefficient.
Centralized integratedcontrol
Centralized operation control of multiple modules is based on the independentrefrigerant circuits of each module,whichrealizesmulti-stage energy regulation by controlling the start and stop of the compressors.
Features
Operatinginformationcanbedisplayedonthecontrol screen,such as temperaturesof outletwaterand returnwater,compressor'sstartandstopstatus, overload protectionstatus,and pressure protection statusofmodulesatall levels.
Basedon thetargetwatertemperatureofthemain pipe,the controllerwill automaticallyselectand start themodules that have the shortest running time forloadingadjustment;andwillautomaticallyskip afailed compressorand start the next one in the line.In the event of unloading,the module with the longest running timewill beautomaticallyselected andstopped forunloadingadjustment.
Parallel arrangement of multiple units
Building Automation Connection (Optional)
Control functions
·Schedule control;usersareallowed to freelyset
automaticswitch time
·Automatic failure alarm and shutdown for the
protection of the unit
·Enable connection with building BA system
·Multi-stage parameter setting ·Systems of independent operation control; intelligent identification and shutdown of failed systems.
·Support individual control and multi-unit parallel control
·Automatically balancing compressor run time
·Multi-stage capacityadjustment
Air-cooledmodularunittechnical parameters
| Model | |||||||||||||
| Type | PowerxUnit | ||||||||||||
| 20STB-V25ADM14 | 60 | 19 | 2 | Copper | 29 | 1.2×2 | 2 | 10 | 1 | 28 | 67 | 800 | |
| 20STB-V30ADM14 | 78 | 24 | 2 | tube with | 40 | 2×2 | 2-1/2" | 13 | 1 | 30 | 68 | 1600 | |
| 20STB-V50ADM14 | 120 | 38 | 4 | corrugated aluminum | 58 | 1.2×4 | 2-1/2" | 21 | 1 | 33 | 69 | 2400 | |
| 20STB-V60ADM14 | 156 | 48 | 4 | fins | 80 | 2×4 | 2-1/2″ | 27 | 1 | 35 | 70 | 3200 | |
| Model | ||||||||||||
| Type | ||||||||||||
| 20STB-25ADM14 | 64 | 17 | 2 | Copper | 29 | 1.2×2 | 2″ | 11 | 1 | 28 | 67 | 800 |
| 20STB-30ADM14 | 80 | 24 | 2 | tube with | 40 | 2×2 | 2-1/2" | 14 | 1 | 30 | 68 | 1600 |
| 20STB-50ADM14 | 128 | 34 | 4 | corrugated aluminum | 58 | 1.2×4 | 2-1/2" | 22 | 1 | 33 | 69 | 2400 |
| 20STB-60ADM14 | 160 | 48 | 4 | fins | 80 | 2×4 | 2-1/2" | 28 | 1 | 35 | 70 | 3200 |
Water-cooledmodularunittechnical parameters
Refrigerant:R410a PowerSupply:3Φ-380V-50Hz
| Model | |||||||||||||
| 20STB-V25WDOM14 | 69 | 16 | 2 | 2″ | 15 | 1 | 56 | 2" | 12 | 1 | 28 | 64 | 520 |
| 20STB-V30WDOM14 | 89 | 20 | 2 | 2-1/2" | 19 | 1 | 58 | 2-1/2″ | 15 | 1 | 30 | 65 | 1000 |
| 20STB-V50WDOM14 | 138 | 32 | 4 | 3" | 30 | 1 | 60 | 2-1/2" | 24 | 1 | 33 | 66 | 1040 |
| 20STB-V60WDOM14 | 178 | 40 | 4 | 3” | 38 | 1 | 61 | 2-1/2″ | 31 | 1 | 35 | 67 | 2000 |
| Model | |||||||||||||
| 20STB-25WDOM14 | 70 | 14 | 2 | 2" | 15 | 1 | 56 | 2 | 12 | 1 | 28 | 64 | 520 |
| 20STB-30WDOM14 | 89 | 20 | 2 | 2-1/2" | 19 | 1 | 58 | 2-1/2" | 15 | 1 | 30 | 65 | 1000 |
| 20STB-50WDOM14 | 140 | 28 | 4 | 3" | 30 | 1 | 60 | 2-1/2" | 24 | 1 | 33 | 66 | 1040 |
| 20STB-60WDOM14 | 178 | 40 | 4 | 3″ | 38 | 1 | 61 | 2-1/2″ | 31 | 1 | 35 | 67 | 2000 |
Note: 1.Nominal cooling capacity reference: evaporator inlet and outlet water temperature 12C 1 7 9 ,condenser inlet and outlet water temperature 3 0 ^ { \circ } \mathsf { C } /35℃;fouling factor 0.018m·℃/kW; 2.Chilled water temperature range: 5℃-20°℃ 3.Coolingwater temperaturerange:15℃ - 4 0 9 0 · 4.Optionalvoltage:220V,380V,400V,415V,440V,460V 5.Specificationsand dimensions willbe subject to improvement change without notice.
Air-cooled heat pump module technical parameters
| Model | ||||||||||||||
| 20STB-V25AHDM14 | 60 | 19 | 66 | 19 | 2 | Copper | 29 | 1.2×2 | 2″ | 28 | 10 | 11 | 68 | 830 |
| 20STB-V30AHDM14 | 78 | 24 | 84 | 24 | 2 | tube with corrugated | 40 | 2×2 | 2-1/2″ | 30 | 13 | 14 | 69 | 1080 |
| 20STB-V50AHDM14 | 120 | 38 | 132 | 38 | 4 | aluminum | 58 | 1.2×42-1/2" | 33 | 21 | 23 | 70 | 1660 | |
| 20STB-V60AHDM14 | 156 | 48 | 168 | 48 | 4 | fins | 80 | 2×4 | 2-1/2″ | 35 | 27 | 29 | 71 | 2160 |
| Model | ||||||||||||||
| 20STB-25AHDM14 | 64 | 17 | 66 | 17 | 2 | Copper | 29 | 1.2×2 | 2” | 28 | 11 | 11 | 68 | 830 |
| 20STB-30AHDM14 | 80 | 24 | 85 | 24 | 2 | tube with corrugated | 40 | 2×2 | 2-1/2″ | 30 | 14 | 15 | 69 | 1080 |
| 20STB-50AHDM14 | 128 | 34 | 132 | 34 | 4 | aluminum | 58 | 1.2×42-1/2" | 33 | 22 | 23 | 70 | 1660 | |
| 20STB-60AHDM14 | 160 | 48 | 170 | 48 | 4 | fins | 80 | 2×4 | 2-1/2″ | 35 | 28 | 29 | 71 | 2160 |
Note:
Watersource heat pumpmodule technical parameters
Refrigerant:R410a PowerSupply:3φ-380V-50Hz
| Model | ||||||||||||||
| 20STB-V25WHDOM14 | 74 | 13 | 87 | 19 | 2 | 2" | 13 | 28 | 2" | 16 | 56 | 68 | 490 | 560 |
| 20STB-V30WHDOM14 | 96 | 18 | 111 | 25 | 2 | 2-1/2″ | 17 | 30 | 2-1/2" | 21 | 58 | 69 | 580 | 650 |
| 20STB-V50WHDOM14 | 148 | 26 | 174 | 38 | 4 | 2-1/2" | 25 | 33 | 3" | 32 | 60 | 70 | 980 | 1120 |
| 20STB-V60WHDOM14 | 192 | 36 | 222 | 50 | 4 | 2-1/2 | 33 | 35 | 3" | 41 | 61 | 71 | 1160 | 1300 |
Note:
| Model | ||||||||||||||
| 中啡 | ||||||||||||||
| 20STB-25WHDOM14 | 74 | 13 | 88 | 17 | 2 | 2" | 13 | 28 | 2″ | 16 | 56 | 68 | 490 | 560 |
| 20STB-30WHDOM14 | 93 | 18 | 114 | 24 | 2 | 2-1/2″ | 16 | 30 | 2-1/2″ | 20 | 58 | 69 | 580 | 650 |
| 20STB-50WHDOM14 | 148 | 26 | 176 | 34 | 4 | 2-1/2" | 25 | 33 | 3" | 32 | 60 | 70 | 980 | 1120 |
| 20STB-60WHDOM14 | 186 | 36 | 228 | 48 | 4 | 2-1/2″ | 32 | 35 | 3″ | 40 | 61 | 71 | 1160 | 1300 |
Lowambient temperature modular air source heat pump parameters
Refrigerant:R22 PowerSupply:3φ-380V-50Hz
| Model | |||||||||||||
| 80HW-15CDSM14 | 14 | 4 | 1品 | 5 | ubewir | 8100 | 0.52*1 | 1-1/4" | 2 | 32 | 75 | 270 | 290 |
| 80HW-30CDSM14 | 24 | 6 | hydrophilic | 8100 | 0.52*1 | 4 | 36 | 75 | 310 | 320 | |||
| 80HW-60CDDM14 | 49 | 13 | 0 50 | 12 | corrugated aluminum fins | 16200 | 1.04*2 | 1-1/2" | 8 | 40 | 75 | 680 | 720 |
| 80HW-80CDDM14 | 55 | 14 | 100 15 | 25600 | 1.56*2 | 9 | 45 | 75 | 810 | 850 | |||
Lowambient temperature modularairsource heat pump parameters
Refrigerant:R410a Power Supply:3φ-380V-50Hz
| Model | Nominal cooling | Nominal heating | Condenser | Evaporator | ||||||||||||
| InputPower | InputPower | |||||||||||||||
| 20STB-V15CDHSM14 | 39 | 12 | 25 | 10 | 1 6 | Coewitrh | 16900 | 1.2*1 | 2" | 7 | 45 | 65 | 650 | 710 | ||
| 20STB-V30CDHSM14 | 77 | 25 | 50 | 21 | 0 50 100 | 12 | hyrruphic aluminum fins | 33800 | 1.2*2 | 13 | 55 | 70 | 1200 | 1290 | ||
| Model | Nominal cooling | Nominal heating | Condenser | Evaporator | |||||||||||
| InputPower KW | InputPower KW | n | |||||||||||||
| 20STB-05CDHS4 | 20 | 4 | 14 | 4 | 0 100 | 3 | 8500 | 0.52*1 | 1-1/4" | 3 | 27 | 65 | 130 | 145 | |
| 20STB-10CDHD4 | 40 | 9 | 27 | 7 | 0 50 | 6 | 170000.52*2 | 7 | 40 | 65 | 270 | 300 | |||
| 20STB-20CDHD4 | 72 | 15 | 49 | 13 | 100 | 10 | 234000.75*2 | 2" | 12 | 50 | 70 | 750 | 810 | ||
Modular Tri-function Combined Coolingand Heating parameters
Refrigerant:R410a Power Supply:3Φ-380V-50Hz
| Model | Nominal | Nominal hot | Nominal | Chilled water | hotwater | Exchanger | AxialFan | |||||||||||||
| 1924 | 810 | 2430 | 6684 | 1924 | 22 | 1317 | 5658 | 22 | 1519 | 2830 | 2940 | 6869 | 100 | 10130 | ||||||
| 6078 | ||||||||||||||||||||
| 30ST-V50AD4M14 | 120 | 38 | 172 | 48 | 132 | 38 | 3" | 26 | 60 | 2-1/2" | 30 | 33 | 58 | 1.2×4 | 68 | 2060 | 2280 | |||
| 30ST-V60AD4M14 | 156 | 48 | 220 | 60 | 168 | 48 | 3" | 34 | 61 | 2-1/2" | 38 | 35 | 2.0×4 | 69 | 25602780 | |||||
Refrigerant:R22 Power Supply:3Φ-380V-50Hz
Note
| Model | Nominal cooling | Nominal hot water | Nominal heating | Chilled water | hotwater | Heat Exchanger | AxialFan | ||||||||||||
| 218 | 2230 | 6685 | 17-24 | 22 | 14-17 | 5658 | 22 | 230 | 2940 | 6869 | 10010 | 101 | |||||||
| 6480 | 17-24 | ||||||||||||||||||
| 30ST-50AD4M14 | 128 | 34 | 184 | 44 | 132 | 34 | 3" | 28 | 60 | 2-1/2" | 31.648 | 33 | 58 | 1.2×4 | 70 2060 | 2280 | |||
| 30ST-60AD4M14 | 160 | 48 | 236 | 60 | 170 | 48 | 3" | 34 | 61 | 2-1/2" | 40.592 | 35 | 80 | 2.0×4 | 71 | 25602780 | |||
Air-cooledmodularunittechnical parameters
| Model | |||||||||||||
| Type | Powerx Unit | 小国 | |||||||||||
| 20STB-V25ADM14 | 72 | 23 | 2 | Copper | 29 | 1.2×2 | 2″ | 12 | 1 | 28 | 67 | 800 | |
| 20STB-V30ADM14 | 94 | 29 | 2 | tube with | 40 | 2×2 | 2-1/2″ | 16 | 1 | 30 | 68 | 1600 | |
| 20STB-V50ADM14 | 144 | 46 | 4 | corrugated aluminum | 58 | 1.2×4 | 2-1/2" | 25 | 1 | 33 | 69 | 2400 | |
| 20STB-V60ADM14 | 187 | 58 | 4 | fins | 80 | 2×4 | 2-1/2" | 32 | 1 | 35 | 70 | 3200 | |
| Model | ||||||||||||
| Type | ||||||||||||
| 20STB-25ADM14 | 77 | 20 | 2 | Copper | 29 | 1.2×2 | 2" | 13 | 1 | 28 | 67 | 800 |
| 20STB-30ADM14 | 96 | 29 | 2 | tube with | 40 | 2×2 | 2-1/2" | 17 | 1 | 30 | 68 | 1600 |
| 20STB-50ADM14 | 154 | 41 | 4 | corrugated aluminum | 58 | 1.2×4 | 2-1/2" | 26 | 1 | 33 | 69 | 2400 |
| 20STB-60ADM14 | 192 | 58 | 4 | fins | 80 | 2×4 | 2-1/2" | 33 | 1 | 35 | 70 | 3200 |
Water-cooledmodularunit technical parameters
Refrigerant:R410a Power Supply:3Φ-440V-60Hz
| Model | |||||||||||||
| 丽 | T | ||||||||||||
| 20STB-V25WDOM14 | 83 | 19 | 2 | 2″ | 18 | 1 | 56 | 2" | 14 | 1 | 28 | 64 | 520 |
| 20STB-V30WDOM14 | 107 | 24 | 2 | 2-1/2" | 23 | 1 | 58 | 2-1/2" | 18 | 1 | 30 | 65 | 1000 |
| 20STB-V50WDOM14 | 166 | 38 | 4 | 3" | 36 | 1 | 60 | 2-1/2" | 29 | 1 | 33 | 66 | 1040 |
| 20STB-V60WDOM14 | 214 | 48 | 4 | 3″ | 46 | 1 | 61 | 2-1/2″ | 37 | 1 | 35 | 67 | 2000 |
| Model | |||||||||||||
| 州 | |||||||||||||
| 20STB-25WDOM14 | 84 | 17 | 2 | 2 | 18 | 1 | 56 | 2" | 14 | 1 | 28 | 64 | 520 |
| 20STB-30WDOM14 | 107 | 24 | 2 | 2-1/2″ | 23 | 1 | 58 | 2-1/2″ | 18 | 1 | 30 | 65 | 1000 |
| 20STB-50WDOM14 | 168 | 34 | 4 | 3" | 36 | 1 | 60 | 2-1/2" | 29 | 1 | 33 | 66 | 1040 |
| 20STB-60WDOM14 | 214 | 48 | 4 | 3″ | 46 | 1 | 61 | 2-1/2″ | 37 | 1 | 35 | 67 | 2000 |
Note: 1.Nominal cooling capacity reference: evaporator inlet and outlet water temperature 12℃ 1 7 9 ,condenser inlet and outlet water temperature 3 0 ^ { \circ } \mathsf { C } /35℃; fouling factor 0.018m·C/kW; 2.Chilled water temperature range:5℃-20℃ 3.Coolingwater temperaturerange:15℃-40℃; 4.Optionalvoltage:220V,380V,400V,415V,440V,460V 5.Specificationsand dimensions willbe subject to improvement change without notice.
Air-cooled heat pump module technical parameters
| Model | ||||||||||||||
| 20STB-V25AHDM14 | 72 | 23 | 79 | 23 | 2 | Copper | 29 | 1.2×2 | 2 | 28 | 12 | 14 | 68 | 830 |
| 20STB-V30AHDM14 | 94 | 29 | 101 | 29 | 2 | tube with corrugated | 40 | 2x2 | 2-1/2″ | 30 | 16 | 17 | 69 | 1080 |
| 20STB-V50AHDM14 | 144 | 46 | 158 | 46 | 4 | aluminum | 58 | 1.2×42-1/2" | 33 | 25 | 27 | 70 | 1660 | |
| 20STB-V60AHDM14 | 187 | 58 | 202 | 58 | 4 | fins | 80 | 2×4 | 2-1/2″ | 35 | 32 | 35 | 71 | 2160 |
| Model | ||||||||||||||
| 20STB-25AHDM14 | 77 | 20 | 79 | 20 | 2 | Copper | 29 | 1.2×2 | 2" | 28 | 13 | 14 | 68 | 830 |
| 20STB-30AHDM14 | 96 | 29 | 102 | 29 | 2 | tube withd | 40 | 2×2 | 2-1/2″ | 30 | 17 | 18 | 69 | 1080 |
| 20STB-50AHDM14 | 154 | 41 | 158 | 41 | 4 | aluminum | 58 | 1.2×42-1/2" | 33 | 26 | 27 | 70 | 1660 | |
| 20STB-60AHDM14 | 192 | 58 | 204 | 58 | 4 | fins | 80 | 2×4 | 2-1/2″ | 35 | 33 | 35 | 71 | 2160 |
Note:
Water source heat pumpmodule technical parameters
Refrigerant:R410a PowerSupply:3Φ-440V-60Hz
| Model | ||||||||||||||
| 中啡 | 中 | |||||||||||||
| 20STB-V25WHDOM14 | 89 | 16 | 104 | 23 | 2 | 2" | 15 | 28 | 2″ | 19 | 56 | 68 | 490 | 560 |
| 20STB-V30WHDOM14 | 115 | 22 | 133 | 30 | 2 | 2-1/2″ | 20 | 30 | 2-1/2″ | 25 | 58 | 69 | 580 | 650 |
| 20STB-V50WHDOM14 | 178 | 31 | 209 | 46 | 4 | 2-1/2 | 31 | 33 | 3" | 38 | 60 | 70 | 980 | 1120 |
| 20STB-V60WHDOM14 | 230 | 43 | 266 | 60 | 4 | 2-1/2 | 40 | 35 | 3″ | 49 | 61 | 71 | 1160 | 1300 |
Note:
| Model | ||||||||||||||
| 中画 | ||||||||||||||
| 20STB-25WHDOM14 | 89 | 16 | 106 | 20 | 2 | 2″ | 15 | 28 | 2" | 19 | 56 | 68 | 490 | 560 |
| 20STB-30WHDOM14 | 112 | 22 | 137 | 29 | 2 | 2-1/2″ | 19 | 30 | 2-1/2″ | 24 | 58 | 69 | 580 | 650 |
| 20STB-50WHDOM14 | 178 | 31 | 211 | 41 | 4 | 2-1/2" | 31 | 33 | 3" | 38 | 60 | 70 | 980 | 1120 |
| 20STB-60WHDOM14 | 223 | 43 | 274 | 58 | 4 | 2-1/2 | 38 | 35 | 3″ | 48 | 61 | 71 | 1160 | 1300 |
Lowambient temperature modular air source heat pump parameters
Refrigerant:R22 PowerSupply:3φ-440V-60Hz
| Model | |||||||||||||
| 80HW-15CDSM14 | 17 | 5 | 5 | tubewirh | 8100 | 0.52*1 | 1-1/4" | 3 | 32 | 75 | 270 | 290 | |
| 80HW-30CDSM14 | 29 | 7 | 1品 | 6 | hydrophilic | 8100 | 0.52*1 | 5 | 36 | 75 | 310 | 320 | |
| 80HW-60CDDM14 | 58 | 14 | 0 50 | 12 | corrugated aluminum fins | 16200 | 1.04*2 | 1-1/2" | 9 | 40 | 75 | 680 | 720 |
| 80HW-80CDDM14 | 66 | 17 | 100 15 | 25600 | 1.56*2 | 11 | 45 | 75 | 810 | 850 | |||
Lowambient temperature modularairsource heat pump parameters
Refrigerant:R410a Power Supply:3φ-440V-60Hz
| Model | Nominal cooling | Nominal heating | Condenser | Evaporator | ||||||||||||
| InputPower | InputPower | ul | ||||||||||||||
| 20STB-V15CDHSM14 | 47 | 14 | 30 | 12 | 10 6 | tCoewith | 16900 1.2*1 | 2" | 8 | 45 | 65 | 650 | 710 | |||
| 20STB-V30CDHSM14 | 94 | 28 | 60 | 24 | 0 50 100 | 12 | hyrrughlic aluminum fins | 33800 | 1.2*2 | 16 | 55 | 70 | 1200 | 1290 | ||
| Model | Nominal cooling | Nominal heating | Condenser | Evaporator | |||||||||||
| InputPower | InputPower | ||||||||||||||
| 20STB-05CDHS4 | 24 | 5 | 17 | 5 | 0 100 | 3 | 8500 | 0.52*1 | 1-1/4" | 4 | 27 | 65 | 130 | 145 | |
| 20STB-10CDHD4 | 48 | 10 | 34 | 10 | 0 50 | 6 | 170000.52*2 | 8 | 40 | 65 | 270 | 300 | |||
| 20STB-20CDHD4 | 86 | 18 | 59 | 16 | 100 | 10 | 234000.75*2 | 2" | 15 | 50 | 70 | 750 | 810 | ||
Modular Tri-function Combined Coolingand Heating parameters
Refrigerant:R410a Power Supply:3Φ-440V-60Hz
| Model | Nominal | Nominal hot | Nomingl Chilledwater | Hotwater | Exchanger | AxialFan | ||||||||||||||
| 2329 | 1512 | 293 | 910 | 2329 | 22 | 1520 | 5658 | 2940 | 6869 | 1010 | 1030 | |||||||||
| 7294 | 22 | 1823 | 2830 | |||||||||||||||||
| 30ST-V50AD4M14 | 144 | 46 | 206 | 58 | 158 | 46 | 3" | 31 | 60 | 2-1/2" | 35 | 33 | 58 | 1.2×4 | 68 | 2060 | 2280 | |||
| 30ST-V60AD4M14 | 187 | 58 | 264 | 72 | 202 | 58 | 3″ | 40 | 61 | 2-1/2" | 45 | 35 | 80 | 2.0×4 | 69 | 25602780 | ||||
Refrigerant:R22 PowerSupply:3φ-440V-60Hz
Note
| Model | Nominal cooling | Nominal hot water | Nominal Chilled water heating | Hotwater | Heat Exchanger | AxialFan | ||||||||||||||
| 2029 | 1012 | 2630 | 79102 | 2029 | 22 | 1721 | 5658 | 1924 | 2830 | 2940 | 12 | 6869 | 10010 | 1030 | ||||||
| 796 | 22 | |||||||||||||||||||
| 30ST-50AD4M14 | 154 | 41 | 221 | 53 | 158 | 41 | 3" | 33 | 60 | 2-1/2" | 38 | 33 | 58 | 1.2×4 | 70 | 2060 | 2280 | |||
| 30ST-60AD4M14 | 192 | 58 | 283 | 72 | 204 | 58 | 3″ | 41 | 61 | 2-1/2″ | 49 | 35 | 80 | 2.0×4 | 71 | 25602780 | ||||
Correction coefficient of water source heating capacity
Correction coefficient ofwater cooled input power
Correction coefficientofaircooled heating capacity
Correction coefficient of air cooled heating input power
Introduction to heat recovery
Heat recoveryisa technology thatappliesa recovery devicetopartiallyorcompletelyrecovertheheat energy generated by the unit during the cooling process,andusesitto providecustomerswith free hot waterof 4 5 ~ 6 5 ^ { \circ } \mathbf { c } . It is suitable for use in large public institutionsand placessuchas hotels,hospitals,and schools.One machine for two purposes,eco-friendly and energy saving.
Having been in theresearchand applicationof heat recoverytechnologyfora longtime,H.Stars Group hasaccumulatedextensive experience in heat recycling,andhasitsownnational patentof heat recovery.Applicationofthetechnologyinprojects providescustomerswith free hotwater,savingalot ofhotwater costs.It reducesthermalpollution to the environmentcausedbycondensation heat,andat the same time lowers the operatingcosts,aswell as the noise of the cooling tower.
Introduction to heat recovery
| Model NO. | 30%Heatrecoveryrate | 100%Heatrecoveryrate | ||
| Heatrecoverymodel | Heating Capacty | Heatrecoverymodel | Heating Capacity | |
| 20STB-25ADM14 | UHR008A | 25 | UHR025A | 75 |
| 20STB-30ADM14 | UHR010A | 30 | UHR030A | 90 |
| 20STB-50ADM14 | UHR016B | 50 | UHR050B | 150 |
| 20STB-60ADM14 | UHR020B | 60 | UHR060B | 180 |
| 20STB-25WDOM14 | UHR008A | 25 | UHR025A | 75 |
| 20STB-30WDOM14 | UHR010A | 30 | UHR030A | 90 |
| 20STB-50WDOM14 | UHR016B | 50 | UHR050B | 150 |
| 20STB-60WDOM14 | UHR020B | 60 | UHR060B | 180 |
Introductionto VSD system
VSDunit ismade byaddingavariable-frequency drive toan existingunit,which can realize operation ofthecompressoratdifferent frequencies.This technologygreatly improves theenergyeficiencyof theunit during partial load operation,making it highly efficient intermsof bothcoefficientofperformance (COP) and integrated part load value (IPLV).
Precise temperaturecontrol
Thewatertemperaturecanbecontrolledwithan accuracytoleranceof ± \ : \ : 0 . 3 \ : degrees,meetingthe requirementsof high-precisiontemperaturecontrol.
Low startup current
VSDscrew units offer soft start function to reduce theimpact of starting current;the frequency convertercomeswithaDC reactorthatcanminimize harmonic interference;andthereisalsoanoptional low harmonic filter which,under the input power of thefrequency converter,isin linewith IEEE-519 specification for harmonicdistortion,and equipped withfunctions of harmonic filter over-temperature protection and capacitorswitching.
Stableandreliable
VSD hot water unit regulates the output load by controlling the speed of the motor speed, whichrealizesreal steplesscapacityadjustment; meanwhile,the reliabilityof the compressor isalso improved.An independentairductisdedicated to cool thevariable-frequencydrivetoensure its lowtemperatureandmorereliableoperation.
| Unitmodel | AuxiliaryelectricheatingkW |
| 20STB-(V)25ADM14 | 25 |
| 20STB-(V)30ADM14 | 30 |
| 20STB-(V)50ADM14 | 50 |
| 20STB-(V)60ADM14 | 60 |
| 20STB-(V)25WDOM14 | 25 |
| 20STB-(V)30WDOM14 | 30 |
| 20STB-(V)50WDOM14 | 50 |
| 20STB-(V)60WDOM14 | 60 |
Useinstructions
In the eventof outdoor heating in regions of extremelylowtemperature,theevaporation temperature of the air source heat pump unit mustbevery low,entailingthecompressor workingata highcompressionratio,which willinevitably lead todecrease ofthe volumetric efficiencyand indicated thermal efficiency of the compressor.Asa result, the heating capacity and the coefficient of performanceof the heat pumparereduced. Apreferredwaytosolvetheproblemisto useauxiliaryheatsourceequipment,and auxiliaryelectric heaterisan idealchoice.
| MODEL | A | B | C | D | E |
| 20STB-(V)25ADM14/20STB-(V)25AHDM14 | 2200 | 1040 | 1950 | 1200 | 1000 |
| 20STB-(V)30ADM14/20STB-(V)30AHDM14 | 2200 | 1300 | 2050 | 1200 | 1260 |
| 20STB-(V)50ADM14/20STB-(V)50AHDM14 | 2200 | 2080 | 1950 | 1200 | 2040 |
| 20STB-(V)60ADM14/20STB-(V)60AHDM14 | 2600 | 2210 | 2050 | 1600 | 2170 |
Single unit basic installation dimension drawing
| MODEL | A | B | C | D | E |
| 20STB-(V)25ADM14/20STB-(V)25AHDM14 | 1200 | 1000 | 2200 | 1040 | 400 |
| 20STB-(V)30ADM14/20STB-(V)30AHDM14 | 1200 | 1260 | 2200 | 1300 | 400 |
| 20STB-(V)50ADM14/20STB-(V)50AHDM14 | 1200 | 2040 | 2200 | 2080 | 1000 |
| 20STB-(V)60ADM14/20STB-(V)60AHDM14 | 1600 | 2170 | 2600 | 2210 | 1000 |
| MODEL | A | B | C | D | E |
| 20STB-(V)25WDOM14/20STB-(V)25WHDOM14 | 1900 | 600 | 1220 | 900 | 400 |
| 20STB-(V)30WDOM14/20STB-(V)30WHDOM14 | 2200 | 600 | 1430 | 1200 | 400 |
| 20STB-(V)50WDOM14/20STB-(V)50WHDOM14 | 1900 | 1200 | 1220 | 900 | 1000 |
| 20STB-(V)60WDOM14/20STB-(V)60WHDOM14 | 2200 | 1200 | 1430 | 1200 | 1000 |
Single unit basic installation dimension drawing
| MODEL | A | B | C | D | E |
| 20STB-(V)25WDOM14/20STB-(V)25WHDOM14 | 900 | 400 | 2000 | 600 | 400 |
| 20STB-(V)30WDOM14/20STB-(V)30WHDOM14 | 1200 | 400 | 2300 | 600 | 400 |
| 20STB-(V)50WDOM14/20STB-(V)50WHDOM14 | 900 | 1000 | 2000 | 1200 | 1000 |
| 20STB-(V)60WDOM14/20STB-(V)60WHDOM14 | 1200 | 1000 | 2300 | 1200 | 1000 |
※please consult the manufacturer or its sales representative for more instalation information.
Dimension drawing of individual unit installation with base
·Installation of theunit can connectup to 16 modules asmaybeallowedby the actual length orwidth of the installationsite.
·A space not less than 5 0 0 \mathsf {mm } must be reserved on theconnection sideof a module,two parallel rows ofunitmustbe keptapartat least 2 0 0 0 \mathsf {mm } ,andthe airoutletmust hasaclearancespaceofnot less than 1 5 0 0 {mm } ,and thereby to ensureadequateair circulation,as well asaccess forsystem maintenance.
·When multiple modules are combined,itis recommended thata dual water supply-return system beused to ensure balanced water pressure of each unitand consequently high operation efficiently.
·The highest point of the water system must be reservedforinstallationoftheexhaustvalveandthe expansion tank.
·Theunitmust be installed onaconcrete foundation oratrough frame;placing directlyon the floorshall be avoidedtopreventcorrosiondamage.
·The circulation water pump of the system must be selected inaccordance with pump head and the demand load of the unit,and with a margin of 3 0 % 元 ·Each module must be equipped with manual shut-off valveand soft joint.
·Standard configuration of water circuit system: water flowswitch,filter,pressure gaugeand pressure bypassvalve.
·The unit is designed to have upwards exhaust airflow;thereforeaspaceof 2 1 5 0 0 {mm } must be reserved.
·When installed ontheroof,ashockabsorbermust beprovidedto prevent resonanceandnoise fromthe operationoftheunit.
Applicationsofwater-cooledmodulechiller
·The main function of the water-cooled module chiller is to cool collectively one or more groups of modulethroughthecentralwatertower.Thissimple and flexible system has low investment cost,and issuitableforplaceswhereoperationisrequiredat different times.
·Themost salientadvantage of the water-cooled module chiller is its high performance inenergy saving;its operatingcost isabout 40 % lower thanan air-coolingmodule
·The system enablessimpleand flexibleuse. Customers can choose the number of units to be turned onaccording to load demands;with supply beingregulatedbydemand,thesystemissimpler, more flexible,and energy-saving than systems of largersize.
Applications of water source module heat pump
·The water source module heat pump derives energy from groundwateror heatcontainingsewage to perform such functions as cooling,heating, and domestic hot water provision.With a cooling coefficientofperformance (COP)ashighas5.0,itis efficientand environmentally friendly,servingmultiple purpose with one unit.
·To use water source heat pump there must be stable watersource,andthewatertemperaturemustbe maintainedat 8 ^ { \circ } \mathsf { C } orabove.
·Modularwater source heat pumps are generally usedin small and medium-sized projects for their advantages of low investment cost,simplicity and flexibility,multi-function and multi-purpose, environmental protection and energy saving.
H.Stars Group
H.Stars (Guangzhou) Refrigerating Equipment Group Ltd., establishedin1992,inEconomic&TechnologicalDevelopment ZoneofGuangzhou,China,composedof8subsidiariesto provide one-stop solutionto HVAC customers,specializing inR&D,production,designandinstallation.Asthecomny grows,H.Starsgroup expandsits businessgloballyand has soldto53differentcountries.H.StarsGroupisawardedwith "NewandHighTechnologyEnterpriseinGuangzhou"andhas become the training baseofmany universities both inChinaand abroadviatechnologycooperation.
H.Stars Group suppliesan extensive line ofCommercial and Industrial Energy SavingHVAC products including: AirCooledChiller,WaterCooledChiller,Industrial Chiller, CentrifugalChiller,Magneticoilfreecentrifugalchiller,MultifunctionChiller,HotWaterUnit,HeatRecoveryUnit,Heat PumpUnit,CondensingUnit,GlycolChiller,hellandTube HeatExchanger,AirHandlingUnit,FanCoilUnit,Cooling Tower,etc.all typeofHVAC products.
H.StarsGrouphasbeendedicatedinqualityand innovation and is technicallystrongin commercialand industrialapplicationasaHVACmanufacturer.Apartfrom obtainingplentyofenergy-savingproductpatents,H.Stars GrouphasachievedCEcertificationsforPressureVesseland standardchillers,BR1,ASME,ISO9001:2000,ISO14001:2004 and other certifications.
Agood reputationofH.StarsGroup hasbeen builtand delivers a full HVAC service to customers worldwide.Our productsarewidelyapplied in industriesforcoolingofLaser generators,Weldingelectrodes,Cuttingmachines,Electric sparkmachines,Extrusion process,Hydraulic ystem, Electroplating,UltrasonicCleaning,IonPlatingfilm,Electronic facility,Electrical appliance components,CompressedGas Dehumidification,Dairyand BeverageCoolingprocessing, Pharmaceutical and Biological products,Medical equipment, GlassCoating,TemperedGlassand Cultivation Sea Food.
H.StarsGroupwill continue to develop energysavingand environmental friendlyequipmenttocreate"TheEfficiency Planet"asour obligation.By focusing on customers' needs and wantsinordertocontributemoreourpotentials,fromnowon, H.StarsGroup will hand in hand with you to bea shiningstar in the foreseeable future.
H.Stars (Guangzhou) Refrigerating Equipment Group Ltd.
Address:No.1 Guoyuan 4th Road,Guangzhou Economic& Technological
Development Zone, HuangPu District,Guangzhou, China Zip Code 510530
Email:sales@hstars.com.cn
Tel: +862062266755 ext. 886
Fax:+862082266081
Website:www.hstarschiller.com
Twitter: twitter.com/HStarsGroup
Facebook:www.facebook.com/Hstarsgroup
Linkedln: www.linkedin.com/company/hstarsgroup
Instagram: www.instagram.com/hstars_chiler_maker