PEOPLE
Power Transmisson & Distribution
PEOPLE ELECTRIC PRODUCT SALES MANUAL
Providing Safer electrical products globally
COMPANY PROFILE
People Ele. Appliance Group was wholly owned company of People Holding Group, one of Chinese Top 500 Enterprise, and founded in the year 1996.
Industrial electrical products as the core business of People Ele. Appliance Group, People Electric owns Zhejiang, Shanghai, Nanchang , Fuzhou, Nantong and Zaozhuang six manufacturing bases, 35 wholly owned subsidiaries, 150 holding member enterprises, over 1500 cooperated processing enterprises and over 5000 sales companies.
The products are popularly sold to over 125 countries and regions, which are widely used in Pudong Airport, Beiing-Shanghai high-speed railway, Three Gorges Hydropower, Beijing Subway, Olympic venues, South North Water Transfer, Qinghai-Tibet Railway, Chang'e Lunar Exploration Project and Vietnam Taian hydropower project etc. major projects at home and abroad, which ranked among the World's Top 500 Machinery Enterprises.
Assess by the World's Brand Laboratory, the brand value reaches to RMB110.927 bilion Yuan.
Perfect industry chain and personalize solutions, Satisfying the different requirements of global customers
Power and energy
• Power
• Petroleum and
petrochemical
• Transportation
Commercial
network
• Bank insurance
• Public construction
• Community facility
Industry and machinery
• Mining / building materials
• Water / water treatment
• Car
Building
• Official building
• Industrial building
• Basic facility
Date center
·IT
• High technology
• Internet
Residence
• Residential construction
• Public construction
• Community facility
More safety
Ensure the safety of life and property
More reliale
Supply the power uninterruptedly
More efficient
Reducing the consumption of energy and the cost, shorten the time of supply
More economic
Optimize the process of the machinery and factory, improving the comfortability of use.
More ecofriendly
Supply the energy through the renewable energy, reducing the carbon emissions
Contents
POWER TRANSFORMER E 001 -021
DISTRIBUTION TRANSFORMER E 022 -044
BOX- TYPE SUBSTATION E 045 -072
POWER TRANSFORMER
People Electric Appliance serves for people.
Intellectualization function and type selection
Transformer built-in, external various sensors and intelligent components;
All signals are collected to the transformer intelligent component cabinet summary, transmission through the optical fiber network, remote intelligent regulation and monitoring, to achieve true "no one on duty".
The intelligent power transformer adds the following additional functions and accessories on the basis of the conventional power transformer functions:
| SerialNumber | Intelligent function | Intelligent components required | Remarks |
| 1 | Winding fibertemperature measurement | Winding fiber online temperaturemeasuring device | It can monitor the temperature rise ofthe top oil and the temperature rise ofthe iron core at the same time, and thenumber of temperature measurementpoints can be customized |
| 2 | Iron core grounding current onlinemonitoring | Iron core grounding current on-linemonitoring device | |
| 3 | Innings placed on line monitoring | Place on line monitoring device | Transformer body and bushing can bemonitored |
| 4 | Oil chromatography online monitoring | Oil chromatographic on-linemonitoring device | Up to 8 kinds of gas + micro watercan be monitored |
| 5 | Oil level 4~20mA signal outputvalue display | Oil level meter remote digitaldisplay instrument | |
| 6 | Oil discharge nitrogen injection firefighting onitoring | Oil discharge nitrogen injection fireextinguishing device | |
| 7 | Cooling system control and monitoring | Cooler control cabinet | Manual, automatic free switching |
| 8 | Intelligent signal summary and remotetransmission | Intelligent component cabinet,intelligent terminal, merging unit | Can choose the need for remotetransmission signal |
Customers can freely combine and choose the above intelligent functions and intelligent components, and the above intelligent components also have their own background system, which can be independent and remote transmission, that is, there is no need to configure intelligent component cabinets, intelligent terminals, and combined units. Multiple transformers can also share a background system to monitor multiple transformers at the same time.
35KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
The main technical parameters
35kV three-phase oil-immersed on-load voltage regulation power transformer has adopted a series of major reforms in material, process and structure, and has the characteristics of small size, light weight, high efficiency, low loss, low noise and reliable operation, which can reduce a large number of power grid losses and operating costs, and has significant economic benefits. It is suitable for power plants, substations, large factories and mining enterprises.
This product conforms to national standards: IEC70076.11 "Power transformers Part 1 General Provisions", IEC70076.11 "Power transformers Part 2 Temperature rise",GB1094.3-2003 "Power transformers Part 3 insulation level, insulation test and external insulation air gap", GB1094.5- 2003 "Power transformers Part 5 ability to withstand short circuit", "Three phase oil immersed power transformer technical parameters and requirements".
35KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
Environmental conditions for use
1, device type: outdoor type
2. Ambient temperature: maximum temperature + 4 0 ^ { \circ } { C } , minimum temperature -30°C
3, altitude: ≤1000 meters (>1000 meters, temperature rise needs to be corrected)
4, relative temperature: ≤90%(25°C)
5, installation site: no corrosive gas, no obvious dirt and other areas
Technical parameters
| Rated | Voltage combination and tap range | CouplinggròupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | ||||
| capacity(kVA) | Highvoltage (kV) | High voltagetap range v | Lowoltage(kV) | |||||||
| 630 | 0.660 | 7.47 | 0.52 | |||||||
| 800 | 0.780 | 8.93 | 0.52 | |||||||
| 1000 | 3.15 | 0.920 | 10.9 | 0.52 | ||||||
| 1250 | 35 | ±2×2.5%±5 | 6.3 | 1.12 | 13.2 | 0.44 | 6.5 | |||
| 1600 | 10.5 | 1.35 | 15.8 | 0.36 | ||||||
| 2000 | Yd11 | 1.74 | 17.4 | 0.36 | ||||||
| 2500 | 2.05 | 18.6 | 0.36 | |||||||
| 3150 | 35-38.5 | ±2×2.5%±5 | 3.156.310.5 | 2.40 | 21.9 | 0.36 | ||||
| 400050006300 | 2.90 | 25.9 | 0.36 | 7.0 | ||||||
| 3.50 | 29.7 | 0.36 | ||||||||
| 4.20 | 33.3 | 0.36 | ||||||||
| 8000 | 3.153.36.3 | YNd11 | 5.80 | 36.5 | 0.28 | |||||
| 10000 | 35-38.5 | ±2×2.5% | 7.00 | 43.0 | 0.28 | |||||
| 12500 | 8.00 | 51.1 | 0.24 | 8.0 | ||||||
| 16000 | 9.70 | 62.5 | 0.24 | |||||||
| 20000 | 6.610.5 | 11.5 | 75.5 | 0.24 | ||||||
| 25000 | 13.6 | 89.3 | 0.20 | 10.0 | ||||||
| 31500 | 16.2 | 106.4 | 0.20 | |||||||
35KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
| Rated | Voltage combination and tap range | Coupling | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | ||||
| (kVA) | Highvoltage (kV) | High voltagetap range | Lowvoltage(kV) | groupLabel | ||||||
| 2000 | 35 | 1.84 | 18.2 | 0.40 | 6.5 | |||||
| 2500 | 2.18 | 19.6 | 0.40 | |||||||
| 3150 | 6.3 | Yd11 | 2.60 | 23.5 | 0.40 | |||||
| 4000 | 35-38.5 | 10.5 | 3.10 | 27.6 | 0.40 | |||||
| 5000 | 3.70 | 32.5 | 0.40 | |||||||
| 6300 | 4.50 | 34.9 | 0.40 | |||||||
| 8000 | ±3×2.5% | 6.30 | 38.6 | 0.32 | ||||||
| 10000 | 7.40 | 45.6 | 0.32 | |||||||
| 12500 | 6.36.6 | 8.70 | 54.0 | 0.28 | 8.0 | |||||
| 16000 | 35-38.5 | YNd11 | 10.5 | 66.8 | 0.28 | |||||
| 20000 | 10.5 | 12.4 | 78.6 | 0.28 | ||||||
| 25000 | 14.6 | 92.9 | 0.24 | 10.0 | ||||||
| 31500 | 17.4 | 110.2 | 0.24 | |||||||
2, according to different operating environments, we can provide specially designed products
3, the medium voltage can be selected to be different from the voltage value in the table or tap, high pressure tap to choose asymmetric voltage regulation tap.
4, short circuit impedance can be selected different from the table median value.
5. The final size shall be subject to the drawing confirmation after the contract is signed.
Features of the organization
35kV three-phase double-winding on-load regulating power transformer
35KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
66KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
Performance parameters
The rated capacity, voltage combinations and tapping range, connection group notation, noload losses, load losses, no-load current, and short-circuit impedance should comply with the provisions of IEC.
When the number of tapping steps and the step voltage remain unchanged, it is permissible to increase the number of negative tapping steps and reduce the number of positive tapping steps, or to increase the number of positive tapping steps and reduce the number of negative tapping steps. For example: 66±3×2.5%, 66±3×25%, etc.
When users require transformers with short-circuit impedance values different from those specified in the table, their loss and other performance parameters should be negotiated with the manufacturer and specified in the contract.
Technical parameters
| Rated | Voltage combination and tap range | CouplinggroupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | |||
| (kVA) | Highvoltage (kV) | High voltagetap range | Lowvoltage(kV) | ||||||
| 630 | 0.96 | 6.75 | 0.90 | 8 | |||||
| 800 | 636669 | ±5 | 6.36.610.5 | Yd11 | 1.20 | 8.08 | 0.85 | ||
| 10001250 | 1.36 | 9.31 | 0.80 | ||||||
| 1.60 | 11.3 | 0.80 | |||||||
| 1600 | 1.92 | 13.3 | 0.80 | ||||||
| 2000 | 2.24 | 15.8 | 0.75 | ||||||
66KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
| Rated | Voltage combination and tap range | CouplinggroupLabel | No loadloss (kW) | Load loss(kW) | No-loadcurrent % | Short circuitimpedance % | |||
| capacity(kVA) | HV(kV) | High voltagetap range | Lowvoltage(kV) | ||||||
| 2500 | Yd11 | 2.72 | 18.6 | 0.75 | |||||
| 3150 | 3.20 | 21.9 | 0.70 | 8 | |||||
| 4000 | 3.80 | 25.9 | 0.64 | ||||||
| 5000 | 4.60 | 29.2 | 0.54 | ||||||
| 6300 | 5.80 | 32.5 | 0.48 | ||||||
| 8000 | 7.10 | 38.5 | 0.48 | ||||||
| 10000 | 8.40 | 45.4 | 0.45 | ||||||
| 12500 | 9.90 | 54.0 | 0.45 | ||||||
| 16000 | 63 | 6.3 | 12.0 | 66.3 | 0.42 | ||||
| 20000 | 66 | ±2×2.5 | 6.6 | YNd11 | 14.1 | 80.4 | 0.42 | 9 | |
| 25000 | 69 | 10.5 | 16.6 | 95.0 | 0.38 | ||||
| 31500 | 19.7 | 114 | 0.35 | ||||||
| 40000 | 23.5 | 134 | 0.35 | ||||||
| 50000 | 28.2 | 158 | 0.32 | ||||||
| 63000 | 33.3 | 188 | 0.29 | ||||||
| Rated | Voltage combination and tap range | CouplinggroupLabel | No loadloss (kW) | Load loss(kW) | No-loadcurrent % | Short circuitimpedance % | ||
| capacity(kVA) | HV(kV) | High voltagetap range | Lowvoltage(kV) | |||||
| 6300 | 6.40 | 32.5 | 0.48 | |||||
| 8000 | 7.70 | 38.5 | 0.48 | |||||
| 10000 | 9.00 | 45.4 | 0.45 | |||||
| 12500 | 10.7 | 54.0 | 0.45 | |||||
| 16000 | 63 | $^ { \pm 4 \times 1 . 2 5 }$ | 6.3 | 12.9 | 66.3 | 0.42 | 9 | |
| 20000 | 66 | $\pm 6 \times 1 . 2 5$ | 6.6 | YNd11 | 15.4 | 80.4 | 0.42 | |
| 25000 | 69 | $\pm 8 \times 1 . 2 5$ | 10.5 | 18.2 | 95.0 | 0.38 | ||
| 31500 | 21.5 | 114 | 0.35 | |||||
| 40000 | 25.8 | 134 | 0.35 | |||||
| 50000 | 30.4 | 158 | 0.32 | |||||
| 63000 | 35.6 | 188 | 0.29 | 10~12 | ||||
110KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATOR ELECTRIC TRANSFORMER
Overview
110kV three-phase oil-immersed on-load voltage regulation power transformer has adopted a series of major reforms in material, process and structure. It has the characteristics of small size, light weight, high efficiency, low loss, low noise and reliable operation, which can reduce a lot of power grid losses and operating costs, and has significant economic benefits. It is suitable for power plants, substations, large factories and mining enterprises.
This product conforms to the national standards: IEC70076.11 "Power transformer Part 1 General provisions", IEC70076.11 "Power transformer Part 2 temperature rise", GB/T 6451- 2023"Power transformer Part 3 insulation level, insulation test and external insulation air gap"
IEC70076.11 "Power transformer Part 5 ability to withstand short circuit", "three-phase oilimmersed power transformer technical parameters and requirements".
Model and meaning
110KV INTELLIGENT THREE-PHASE NO-LOAD VOLTAGE REGULATION POWER TRANSFORMER
Enabling
1, device type: outdoor type
2. Ambient temperature: maximum temperature +40°C, minimum temperature -30°C
3, altitude: ≤1000 meters (>1000 meters, temperature rise needs to be corrected)
4, relative temperature: ≤90%(25°C)
5, installation site: no corrosive gas, no obvious dirt and other areas
Technical parameters
| Ratedcapacity | Voltage combination and tap range | CouplinggroupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | ||
| (kVA) | High voltage(kV) | Lowvoltage(kV) | ||||||
| 6300 | 5.90 | 33.0 | 0.50 | |||||
| 8000 | 7.10 | 40.0 | 0.50 | |||||
| 10000 | 8.40 | 48.0 | 0.46 | |||||
| 12500 | 9.90 | 56.0 | 0.46 | |||||
| 16000 | 6.3 | 12.0 | 69.0 | 0.43 | ||||
| 20000 | 6.6 | 14.1 | 84.0 | 0.43 | 10.5 | |||
| 25000 | 110±2×2.5%115±2×2.5%121±2×2.5% | 10.5 | 16.6 | 99.0 | 0.40 | |||
| 31500 | YNd11 | 19.7 | 117 | 0.38 | ||||
| 40000 | 23.5 | 141 | 0.36 | |||||
| 50000 | 28.2 | 166 | 0.34 | |||||
| 63000 | 33.3 | 198 | 0.30 | |||||
| 75000 | 13.815.751821 | 37.8 | 224 | 0.26 | ||||
| 90000 | 43.5 | 258 | 0.24 | |||||
| 120000 | 54.2 | 320 | 0.22 | 12~14 | ||||
| 150000 | 64.1 | 379 | 0.19 | |||||
| 180000 | 72.0 | 434 | 0.16 | |||||
Note 1, -5% tap position for maximum current tap.
Note 2, for the boost transformer, it is appropriate to use the tapless structure. If required by operation, tap can be set
Note 3, when the transformer annual average load rate is between 45%-46%, the loss value in the table can be used to obtain the highest operating efficiency.
110KVINTELLIGENT THREE-PHASE NO-LOAD VOLTAGE REGULATING POWER TRANSFORMER
| Ratedcapacity(kVA) | Voltage combination and tap range | Coupling | No load | Load | No-loadloss | Short circuitimpedance % | |||
| High voltage(kV) | Mediumvoltage(kV)v | Lowoltage(kV) | groupLabel | loss kW(9) | kW(9) | current % | Open voltage | Depressurize | |
| 6300 | 7.10 | 42.0 | 0.53 | ||||||
| 8000 | 8.50 | 50.0 | 0.50 | ||||||
| 10000 | 10.1 | 59.0 | 0.47 | ||||||
| 12500 | 6.36.610.521 | Ynyn0d11 | 11.8 | 70.0 | 0.45 | ||||
| 16000 | 110±2×2.5% | 35 | 14.3 | 86.0 | 0.42 | High-mediu17.5~18.5 | High-mediumm10.5 | ||
| 20000 | 115±2×2.5% | 37 | 16.9 | 101 | 0.42 | High - Low10.5 | High-Low18~19 | ||
| 25000 | 121±2×2.5% | 38.5 | 19.7 | 120 | 0.38 | Medium-Low6.5 | Medium-low6.5 | ||
| 31500 | 23.5 | 142 | 0.38 | ||||||
| 40000 | 27.8 | 170 | 0.35 | ||||||
| 50000 | 33.3 | 202 | 0.35 | ||||||
| 63000 | 39.4 | 243 | 0.32 | ||||||
| Ratedcapacity | Voltage combination and tap range | CouplinggroupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | ||
| C(kVA) | High voltage(kV) | Lowvoltage(kV) | ||||||
| 6300 | 6.40 | 33.0 | 0.51 | |||||
| 8000 | 110±8×1.25% | 6.36.610.521 | YNd11 | 7.70 | 40.0 | 0.47 | ||
| 10000 | 9.00 | 48.0 | 0.47 | |||||
| 12500 | 10.7 | 56.0 | 0.47 | 10.5 | ||||
| 16000 | 12.9 | 69.0 | 0.44 | |||||
| 20000 | 15.4 | 84.0 | 0.44 | |||||
| 25000 | 18.2 | 99.0 | 0.41 | |||||
110KVINTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
| Ratedcapacity | Voltage combination and tap range | CouplinggroupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | |
| (kVA) | High voltage(kV) | Lowvoltage(kV) | |||||
| 31500 | 6.3 | 21.6 | 117 | 0.41 | 10.5 | ||
| 40000 | 110±8×1.25% | 6.6 | 25.8 | 148 | 0.37 | ||
| 50000 | 10.5 | 30.6 | 184 | 0.37 | 10.5~18 | ||
| 63000 | 21 | 36.3 | 220 | 0.34 | |||
Note 2, according to user requirements, can provide other voltage combination products.
Note 3, -10% tap position is the maximum current tap.
Note 4, when the transformer annual average load rate is between 45%-50%, the loss value in the table can be used to obtain the highest operating efficiency
| Rated | Voltage combination and tap range | CouplingLrou | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | |||||
| (kVA) | High voltage(kV) | Mediumvoltage(kV) | Lowvoltage(kV) | ||||||||
| 6300 | 7.70 | 42.0 | 0.61 | ||||||||
| 8000 | 9.20 | 50.0 | 0.61 | ||||||||
| 10000 | 10.9 | 59.0 | 0.57 | ||||||||
| 12500 | 6.36.610.5 | 12.9 | 70.0 | 0.57 | |||||||
| 16000 | 36 | 15.4 | 86.0 | 0.54 | High-medium10.5 | ||||||
| 200001 | 10±8×1.25% | 37 | |||||||||
| YNyn0d11 | 18.2 | 101 | 0.54 | High-Low18~19Medium-low6.5 | |||||||
| 25000 | 38.5 | 21 | 21.6 | 120 | 0.50 | ||||||
| 31500 | 25.7 | 142 | 0.50 | ||||||||
| 40000 | 30.8 | 170 | 0.46 | ||||||||
| 50000 | 36.4 | 202 | 0.46 | ||||||||
| 63000 | 43.3 | 243 | 0.42 | ||||||||
Note 1, load regulating transformer, temporarily provide buck structure products.
Note 2, high, medium and low voltage winding capacity allocation is (100/100/100)%.
Note 3. The connection group label can be YNd11y10 if required.
Note 4. The -10% tap position is the maximum current tap.
Note 5. According to user requirements, the medium voltage can be selected to be different from the voltage value in the table or set the tap.
Note 6, when the transformer annual average load rate is about 47%, the loss value in the table can be used to obtain the highest operating efficiency
110KV GRADE INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
| Ratedcapacity | Voltage combination and tap range | CouplinggroupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | |
| (kVA) | High voltage(kV) | Lowvoltage(kV) | |||||
| 6300 | 6.40 | 35.0 | 0.54 | ||||
| 8000 | 7.70 | 42.0 | 0.54 | ||||
| 10000 | 9.0 | 49.0 | 0.50 | 10.5 | |||
| 12500 | 10.5 | 59.0 | 0.50 | ||||
| 16000 | 110±2×2.5% | 36 | 12.5 | 72.0 | 0.46 | ||
| 20000 | 115±2×2.5% | 37 | YNd11 | 14.8 | 89.0 | 0.46 | |
| 25000 | 121±2×2.5% | 38.5 | 17.5 | 105 | 0.42 | ||
| 31500 | 20.7 | 126 | 0.42 | ||||
| 40000 | 24.6 | 147 | 0.39 | ||||
| 50000 | 29.5 | 183 | 0.39 | ||||
| 63000 | 34.9 | 220 | 0.36 | ||||
The no-load loss values in the above parameter table are the Chinese national standard type 18 parameter values. The company can customize them according to the actual needs of users.
current tap.
Note 2, for the boost transformer, it is appropriate to use the tapless structure. If required by operation, tap can be set
Note 3, when the average annual load of the transformer is between 44%-47%, the loss value in the table can be used to obtain the highest operating efficiency.
1, according to user requirements, can produce products outside the capacity of the table, its performance parameters depending on the requirements.
2, according to different operating environments, we can provide specially designed products.
3, the medium voltage can be selected to be different from the voltage value in the table or tap, high pressure tap to choose asymmetric voltage regulation tap.
4, short circuit impedance can be selected different from the table median value.
5. The final size shall be subject to the drawing confirmation after the contract is signed.
Structural features
110kV three-phase double winding on-load voltage regulating power transformer Different specifications of power transformers can be developed according to the special requirements of users.
220KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATOR ELECTRIC TRANSFORMER
Overview
220kV three-phase oil-immersed on-load voltage regulation power transformer has adopted a series of major reforms in material, process and structure. It has the characteristics of small size, light weight, high efficiency, low loss, low noise and reliable operation, which can reduce a lot of power grid losses and operating costs, and has significant economic benefits. It is suitable for power plants, substations, large factories and mining enterprises.
This product conforms to the national standards: IEC70076.11 "Power transformer Part 1 General provisions", IEC70076.11 "Power transformer Part 2 temperature rise", GB/T 6451- 2023"Power transformer Part 3 insulation level, insulation test and external insulation air gap"
IEC70076.11 "Power transformer Part 5 ability to withstand short circuit", "three-phase oilimmersed power transformer technical parameters and requirements".
Model and meaning
220KV INTELLIGENT THREE-PHASE NO-LOAD VOLTAGE REGULATION POWER TRANSFORMER
Technical parameter
31500kVA-420000kVA three-phase double-winding unexcited voltage regulating power transformer
| Ratedcapacity | Voltage combination and tap range | CouplingLtabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | ||||
| (kVA) | High voltage(kV) | Lowvoltage(kV) | ||||||||
| 31500 | 28.0 | 128 | 0.56 | |||||||
| 40000 | 6.36.610.5 | 32.0 | 149 | 0.56 | ||||||
| 50000 | 39.0 | 179 | 0.52 | 12~14 | ||||||
| 63000 | 46.0 | 209 | 0.52 | |||||||
| 75000 | 10.513.8 | 53.0 | 237 | 0.48 | ||||||
| 90000 | 64.0 | 273 | 0.44 | |||||||
| 120000 | 75.0 | 338 | 0.44 | |||||||
| 150000 | 220±2×2.5% | Ynd11 | 89.0 | 400 | 0.40 | |||||
| 160000 | 242±2×2.5% | 1 .5、13.815.7518、20 | 93.0 | 420 | 0.39 | |||||
| 180000 | 102 | 459 | 0.36 | |||||||
| 240000 | 128 | 538 | 0.33 | |||||||
| 300000 | 15.751820 | 154 | 641 | 0.30 | ||||||
| 360000 | 173 | 735 | 0.30 | |||||||
| 370000 | 176 | 750 | 0.30 | |||||||
| 400000 | ||||||||||
| 187 | 795 | 0.28 | ||||||||
| 420000 | 193 | 824 | 0.28 | |||||||
Note 1 Transformers with rated capacity less than 31500kVA and transformers with other voltage combinations are also available on request.
Note 2. Transformers with low voltage of 35kV or 38.5kV can also be supplied according to the requirements.
Note 3. Tapless structure is preferred. If required by operation, tap can be set
Note 4, when the transformer annual average load rate is between 45%-50%, the loss value in the table can be used to obtain the highest operating efficiency.
220KV INTELLIGENT THREE-PHASE NO-LOAD VOLTAGE REGULATION POWER TRANSFORMER
| Ratedcapacity(kVA) | Voltage combination and tap range | CouplinggroupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | ||||||||
| High voltage(kV) | Mediumvoltage(kV)v | Lowoltage(kV) | Openpressure K | Depressurize | ||||||||||
| 31500 | 32.0 | 153 | 0.56 | |||||||||||
| 40000 | 6.3、6.610.5、21 | |||||||||||||
| 38.0 | 183 | 0.50 | ||||||||||||
| 50000 | 36、3738.5 | 44.0 | 216 | 0.44 | High- | High - | ||||||||
| 63000 | 220±2×2.5% | 52.0 | 257 | 0.44 | medium | Medium | ||||||||
| 90000 | 230±2×2.5%242±2×2.5% | 115121 | 10.5 13.836 3738.5 | Ynyn0d11 | 68.0 | 333 | 0.39 | 22~24High-low12~14 | 12~14High-low22~24 | |||||
| 120000 | 84.0 | 410 | 0.39 | |||||||||||
| 150000 | 10.5 13.815.75 21 | 100 | 487 | 0.33 | Medium- | |||||||||
| 180000 | ||||||||||||||
| 113 | 555 | 0.33 | low 7~9 | low7~9 | ||||||||||
| 240000 | 36 3738.5 | 140 | 684 | 0.28 | ||||||||||
| 300000 | 166 | 807 | 0.24 | |||||||||||
Note 1 The capacity allocation for load losses in the table is (100/100/100)%. The capacity allocation of the booster structure can be (100/50/100)%, and the capacity allocation of the stepdown structure can be (100/50/100)% or (100/50/100)%.
Note 2, Transformers with rated capacity less than 31500kVA and transformers with other voltage combinations can also be provided according to requirements. Note 3, transformers with low voltage of 35kV can also be provided according to the requirements.
Note 4. The tapless structure is preferred. If required by operation, tap can be set.
Note 5, when the transformer annual average load rate is about 45%, the loss value in the table can be used to obtain the highest operating efficiency.
31500kVA-240000kVA low-voltage 66kV three-phase double-winding unexcited voltage regulating power transformer
| Ratedcapacity | Voltage combination and tap range | CouplinggroupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | Short circuitimpedance % | ||||
| (kVA) | High voltage(kV) | Lowvoltage(kV) | ||||||||
| 31500 | 30.0 | 143 | 0.71 | |||||||
| 40000 | 36.0 | 167 | 0.71 | |||||||
| 50000 | 42.0 | 200 | 0.65 | 12~14 | ||||||
| 63000 | 636669 | Ynd11 | 50.0 | 234 | 0.65 | |||||
| 90000 | ||||||||||
| 220±2×2.5% | 66.0 | 306 | 0.60 | |||||||
| 120000 | 230±2×2.5% | 81.0 | 367 | 0.60 | ||||||
| 150000 | 97.0 | 430 | 0.54 | |||||||
| 150000 | 97.0 | 430 | 0.54 | |||||||
| 180000 | 110 | 487 | 0.54 | |||||||
| 240000 | 136 | 603 | 0.48 | |||||||
220KVINTELLIGENT THREE-PHASE NO-LOAD VOLTAGE REGULATION POWER TRANSFORMER
Note 1. Tapless construction is preferred. If required by operation, tap can be set. Note 2, when the transformer annual average load rate is between 45%-50%, the loss value in the table can be used to obtain the highest operating efficiency.
31500kVA-240000kVA three-phase three-winding unexcited voltage regulating autotransformer
| Rated | Voltage combination and tap range | CouplinggroupLabel | No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | ||
| capacity(kVA) | High voltage(kV) | Mediumvoltage(kV) | Lowvoltage(kV) | ||||
| 31500 | 16.0 | 105 | 0.36 | ||||
| 40000 | 220±2×2.5%230 ±2×2.5%242±2×2.5% | 115121 | 6.6、10.521、3637、38.510.5、13.815.7518、21、36、3738.5 | YNa0d11 | 18.0 | 129 | 0.36 |
| 50000 | 22.0 | 153 | 0.32 | ||||
| 63000 | 26.0 | 181 | 0.32 | ||||
| 90000 | 32.0 | 249 | 0.27 | ||||
| 120000150000180000 | 39.0 | 307 | 0.27 | ||||
| 46.0 | 365 | 0.22 | |||||
| 54.0 | 417 | 0.22 | |||||
| 240000 | 63.0 | 518 | 0.21 | ||||
| Boost combination | Short circuit impedance % | |||||
| No loadloss kW(9) | Load losskW(9) | No-loadcurrent % | step-up voltage | step-down voltage | ||
| 16.0 | 89.0 | 0.32 | High - Medium8~10High-low High-low28~34Medium-low Medium-low14~18 18~24 | |||
| 16.0 | 108 | 0.32 | ||||
| 19.0 | 129 | 0.27 | ||||
| 22.0 | 154 | 0.27 | ||||
| 29.0 | 211 | 0.22 | Hig | |||
| 35.0 | 259 | 0.22 | ||||
| 42.0 | 308 | 0.21 | ||||
| 48.0 | 349 | 0.21 | ||||
| 57.0 | 454 | 0.16 | ||||
220KV INTELLIGENT THREE-PHASE NO-LOAD VOLTAGE REGULATION POWER TRANSFORMER
Note 1. The capacity allocation of the booster structure is (100/50/100)%. The capacity allocation of the step-down structure is (100/100/50)%.
Note 2, the value of the short circuit impedance in the table is 100% of the rated capacity.
Note 3. Transformers with a low voltage of35kV are also available upon request
Note 4. The tapless structure drawing is preferred. Ifrequired by operation, tap can be set.
Note 5, when the transformer annual average load rate is about 40%, the loss value in the table canbe used to obtain the highest operating efficiency.
| Rated | Voltage combination andtap range | Coupling. | Boost combination | Buck combo | Short circuit impedance % | ||||||||
| capacity(kVA) | Highvoltage(kv) | Mediumvoltage(kV) | Lowvoltage(kv) | groupNo | load | Load | No-load N | o load | LoadN | o-load | Openpressure | Depressurize | |
| Label | w | loss(kW) | current% | loss(kW) | loss(kW) | current% | |||||||
| 31500 | 6.6 | 16.0 | 105 | 0.36 | 14.0 | 89 | 0.32 | ||||||
| 40000 | 10.521 | 18.0 | 129 | 0.36 | 16.0 | 108 | 0.32 | ||||||
| 50000 | 3637 | 22.0 | 153 | 0.32 | 19.0 | 129 | 0.27 | ||||||
| High -Medium8~9High-low28~34Mediumlow18~24 | |||||||||||||
| 630002 | 20+2×2.5 | 115 | 38.5 | 26.0 | 181 | 0.32 | 22.0 | 154 | 0.27 | High-medium12~14 | |||
| 900002 | 30+2×2.5 | 121 | 10.513.8 | Yna0d11 | 32.0 | 249 | 0.27 | 29.0 | 211 | 0.22 | High-low8~12 | ||
| 12000024 | 2+2×2.5 | 15.75 | 39.0 | 307 | 0.27 | 35.0 | 259 | 0.22 | Medium-low14~18 | ||||
| 150000 | 1821 | 46.0 | 365 | 0.22 | 42.0 | 308 | 0.21 | ||||||
| 180000 | 363738.5 | 54.0 | 417 | 0.22 | 48.0 | 349 | 0.21 | ||||||
| 240000 | 240000 | 63.0 | 518 | 0.21 | 57.0 | 454 | 0.16 | ||||||
Note 2. When the average annual load ratio of the transformer is about 50%, the loss value in the table can be used to obtain the highest operating efficiency.
220KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
| Rated | Voltage combination and tap range | Coupling | Boost combination | Short-Circuit | |||||
| capacity(kVA) | High voltage(kV) | Mediumvoltage(kV) | Lowvoltage(kV) | groupLabel | No loadloss kW | Load losskW | No-loadcurrent % | Impedance(%) | |
| 31500 | 6.36.610.52136 | 24.0 | 122 | 0.46 | 12~14 | ||||
| 40000 | 29.0 | 142 | 0.46 | ||||||
| 50000 | 34.0 | 170 | 0.42 | ||||||
| 63000 | 3738.5 | 40.0 | 199 | 0.42 | |||||
| 90000 | 10.5 | 51.0 | 259 | 0.36 | |||||
| 120000 | 220230 | ±4×1.25±6×1.25±8×1.25 | 213637 | Ynd11 | 63.0 | 321 | 0.36 | ||
| 150000 | 74.0 | 380 | 0.33 | ||||||
| 180000 | 38.5 | 86.0 | 436 | 0.30 | |||||
| 120000 | 65.0 | 320 | 0.36 | ||||||
| 150000 | 66 | 77.0 | 374 | 0.33 | |||||
| 180000 | 69 | 90.0 | 428 | 0.30 | |||||
| 240000 | 112 | 532 | 0.24 | ||||||
| Rated | Voltage combination and tap range | Coupling | Boost combination | Short-Circuit | |||||
| capacity(kVA) | H V(kV) | High voltageTap Range(%) | M V(kV) | L V(kV) | groupLabel | No loadloss kW | Load losskW | No-loadcurrent % | Impedance(%) |
| 31500 | 6.36.610.52136 | 28.0 | 145 | 0.50 | |||||
| 40000 | 33.0 | 174 | 0.48 | High-Medium12~14High-Low22~24Medium-Low7~9 | |||||
| 50000 | 38.0 | 205 | 0.48 | ||||||
| 63000 | 220 | ±4×1.25 | 69 | 3738.5 | 45.0 | 244 | 0.44 | ||
| 90000 | 230 | ±6×1.25±8×1.25 | 115121 | 10.521 | Ynyn0d11 | 58.0 | 316 | ||
| 120000 | 74.0 | 390 | 0.35 | ||||||
| 150000 | 36 | 86.0 | 463 | 0.31 | |||||
| 180000 | 3738.5 | 99.0 | 568 | 0.31 | |||||
| 240000 | 123 | 704 | 0.28 | ||||||
220KV INTELLIGENT THREE-PHASE ON-LOAD VOLTAGE REGULATION POWER TRANSFORMER
Three-phase three-winding on-load voltage regulating autotransformer with a voltage class of 220 kV and a capacity range from 31500 kVA to 240000 kVA.
| Rated | Voltage combination and tap range | Coupling | Boost combination | Short-Circuit | ||||||
| capacity(kVA) | H V(kV) | High voltageTap Range(%) | M V(kV) | LV(kV) | groupLabel | No loadloss kW | Load losskW | No-loadcurrent % | Impedance(%) | |
| 31500 | 6.36.610.521363738.5 | 16.0 | 97.0 | 0.35 | ||||||
| 40000 | 19.0 | 119 | 0.35 | |||||||
| 50000 | 22.0 | 142 | 0.31 | |||||||
| 63000 | 220 | ±4×1.25 | 115 | 26.0 | 170 | 0.31 | High-Medium8~11 | |||
| 90000 | 230 | ±6×1.25±8×1.25 | 121 | 10.521 | Yna0d11 | 32.0 | 222 | 0.26 | High-Low28~34Medium-Low18~24 | |
| 120000 | 41.0 | 277 | 0.26 | |||||||
| 150000 | 36 | 48.0 | 329 | 0.22 | ||||||
| 180000 | 3738.5 | 54.0 | 378 | 0.22 | ||||||
| 240000 | 66.0 | 487 | 0.19 | |||||||
220KV INTELLIGENT THREE-PHASE NO-LOAD VOLTAGE REGULATION POWER TRANSFORMER
Structural features
220kV class three-phase double-winding on-load voltage regulating power transformer According to the special requirements
DISTRIBUTION TRANSFORMER
People Electric Appliance serves for people.
SC(B)11, SCR11,SERIES RESIN-INSULATED DRY TYPE TRANSFORMERS
| Ratedcapacity(kVA) | loss (W) | Short-circuitimpedance(%) | No-loadcurrent(%) | Vectorgroup | Overalldimensions (mm)LxWxH | Mountingdimensions(mm) | |
| No-loadloss | Load loss | ||||||
| Grade F | |||||||
| 30 | 170 | 710 | 4 | 2.3 | 880×660×800 | 400×400 | |
| 50 | 240 | 1000 | 4 | 2.2 | 910×660×860 | 400×400 | |
| 80 | 330 | 1380 | 4 | 1.7 | 970×660×950 | 550×550 | |
| 100 | 360 | 1570 | 4 | 1.7 | 980×660×975 | 550×550 | |
| 125 | 420 | 1850 | 4 | 1.5 | 1030×660×1015 | 550×550 | |
| 160 | 480 | 2130 | 4 | 1.5 | 1070×660×1030 | 550×550 | |
| 200 | 550 | 2530 | 4 | 1.3 | 1130×660×1085 | 550×500 | |
| 250 | 640 | 2760 | 4 | 1.3 | 1150×660×1090 | 550×550 | |
| 315 | 790 | 3470 | 4 | 1.1 | 1150×660×1100 | 660×660 | |
| 400 | 880 | 3990 | 4 | 1.1 | Yyn0/Dyn11 | 1200×770×1110 | 820×820 |
| 500 | 1040 | 4880 | 4 | 1.1 | 1320×860×1130 | 820×820 | |
| 630 | 1200 | 5880 | 4 | 0.9 | 1420×960×1100 | 820×820 | |
| 630 | 1170 | 5960 | 6 | 0.9 | 1420×960×1150 | 820×820 | |
| 800 | 1360 | 6960 | 6 | 0.9 | 1500×960×1190 | 820×820 | |
| 1000 | 1590 | 8130 | 6 | 0.9 | 1550×960×1220 | 820×820 | |
| 1250 | 1880 | 9690 | 6 | 0.9 | 1620×1050×1250 | 1070×1070 | |
| 1600 | 2200 | 11730 | 6 | 0.9 | 1690×1255×1360 | 1070×1070 | |
| 2000 | 2740 | 14450 | 6 | 0.7 | 1700×1255×1460 | 1070×1070 | |
| 2500 | 3240 | 17170 | 6 | 0.7 | 1920×1255×1480 | 1070×1070 | |
SCB12 SERIES EPOXY RESIN CAST DRY TYPE TRANSFORMER
The main technical parameters
| Ratedcapacity(kVA) | Connectiongroup label | No-loadloss(W) | Load lossClass F(W) | No-loadcurrent(%) | Short circuitimpedance(%) | Mountingdimensions(mm) | Overalldimensions(mm)LXWXH |
| 30 | 150 | 710 | 2.3 | 400×400 | 880×660×800 | ||
| 50 | 215 | 1000 | 2.2 | 400×400 | 910×660×860 | ||
| 80 | 295 | 1380 | 1.7 | 400×400 | 970×660×950 | ||
| 100 | 320 | 1570 | 1.7 | 400×400 | 980×660×975 | ||
| 125 | 375 | 1850 | 1.5 | 550×550 | 1030×660×985 | ||
| 160 | 430 | 2130 | 1.5 | 4.0 | 550×550 | 1070×660×1000 | |
| 200 | 495 | 2530 | 1.3 | 550×550 | 1130×660×1055 | ||
| 250 | 575 | 2760 | 1.3 | 550×550 | 1150×660×1060 | ||
| 315 | Yyn0 | 705 | 3470 | 1.1 | 660×660 | 1200×770×960 | |
| 400 | or | 785 | 3990 | 1.1 | 660×660 | 1190×770×980 | |
| 500 | Dyn11 | 930 | 4880 | 1.1 | 660×660 | 1220×770×1000 | |
| 630 | 1070 | 5880 | 0.9 | 820×850 | 1370×960×1005 | ||
| 630 | 1040 | 5960 | 0.9 | 820×850 | 1370×960×1005 | ||
| 800 | 1215 | 6960 | 0.9 | 820×900 | 1440×960×1030 | ||
| 1000 | 1415 | 8130 | 0.9 | 820×820 | 1500×960×1045 | ||
| 1250 | 1670 | 9690 | 0.9 | 6.0 | 820×820 | 1550×960×1095 | |
| 1600 | 1960 | 11730 | 0.9 | 820×1070 | 1620×1200×1195 | ||
| 2000 | 2440 | 14450 | 0.7 | 820×1070 | 1730×1200×1390 | ||
| 2500 | 2880 | 17170 | 0.7 | 1070×1070 | 1780×1200×1430 |
SC(B)13 SERIES EPOXY RESIN CASTENERGY SAVING DRY TYPE DISTRIBUTIONTRANSFORMER
Product overview
SCB13 energy-saving dry distribution transformer is based on the absorption of foreign advanced technology and advanced experience in the same industry, through our company's scientific and reasonable electromagnetic calculation and new pouring process, design and development of a new generation of energy-saving, environmentally friendly dry distribution transformer, products with flame retardant, fire proof, explosion-proof, small size, maintenance-free, pollution-free and other characteristics. The product is widely used in urban power grid, high-rise buildings, business centers, theaters, hospitals, hotels, tunnels, subways, underground power stations, laboratories, stations, wharfs, airports, combined substations and other important places.
SCB13 energy-saving dry distribution transformer core adopts a new all-inclined, seven-step cascade joint form. Compared with the conventional joint core, it can reduce the magnetic density at the joint by about 22%, reduce the no-load loss by about 3%, reduce the transformer noise by 2- 3 dB, and reduce the no-load current by about 40%. Stack 7 pieces ata time, which greatly improves the stack efficiency. The clamping parts are made of automatic laser cutting steel plate CNC bending structure. The bending parts have the advantages of fewer parts, high machining precision, accurate positioning, simple assembly, simple surface treatment and painting process. PET(H class) insulation material is used for core insulation to ensure that the transformer will not produce discharge, leakage, breakdown and other phenomena; Clip from the whole look smooth lines, smooth appearance, and beautiful.
Main technical parameters
| Ratedcapacity(kVA) | Voltage groupus | No-loadloss(W) | Loadloss(W) | No-loadcurrent(%) | Short circuitimpedance(%) | |||
| Highvoltage(kV) | Highpressureptap range | Lowressure (kV) | ConnectiongroupLabel | |||||
| 30 | 130 | 640 | 1.7 | |||||
| 50 | 195 | 900 | 1.7 | |||||
| 80 | 265 | 1240 | 1.5 | |||||
| 100 | 290 | 1415 | 1.5 | |||||
| 160 | 385 | 1915 | 1.3 | 4.0 | ||||
| 200 | 445 | 2275 | 1.1 | |||||
| 250 | 515 | 2485 | 1.1 | |||||
| 315 | 10 | ±5%; | Dyn11 | 635 | 3125 | 1.0 | ||
| 400 | 10.5 | or | 0.4 | or | 705 | 3591 | 1.0 | |
| 500 | 11 | ±2×2.5 | Yyn0 | 835 | 4390 | 1.0 | ||
| 630 | 935 | 5365 | 0.8 | |||||
| 800 | 1095 | 6265 | 0.8 | |||||
| 1000 | 1275 | 7315 | 0.8 | |||||
| 1250 | 1505 | 8720 | 0.8 | 6.0 | ||||
| 1600 | 1765 | 10555 | 0.7 | |||||
| 2000 | 2195 | 13005 | 0.7 | |||||
| 2500 | 2590 | 15455 | 0.6 | |||||
SCB14 SERIES EPOXY RESIN CAST DRY TYPE TRANSFORMER
The main technical parameters
| Ratedcapacity(kVA) | Connectiongrouplabel | No-loadloss( W) | Load lossClass F (W) | No-loadcurrent(%) | Short circuitimpedance(%) | Mountingdimensions(mm) | Overalldimensions(mm) LXWXH |
| 30 | 130 | 640 | 2.3 | 400×400 | 880×660×800 | ||
| 50 | 185 | 900 | 2.2 | 400×400 | 910×660×860 | ||
| 80 | 250 | 1240 | 1.7 | 400×400 | 970×660×950 | ||
| 100 | 270 | 1415 | 1.7 | 400×400 | 980×660×975 | ||
| 125 | 320 | 1665 | 1.5 | 550×550 | 1030×660×985 | ||
| 160 | 365 | 1915 | 1.5 | 550×550 | 1070×660×1000 | ||
| 200 | 420 | 2275 | 1.3 | 550×550 | 1130×660×1055 | ||
| 250 | 490 | 2485 | 1.3 | 550×550 | 1150×660×1060 | ||
| 315 | Yyn0 | 600 | 3125 | 1.1 | 660×660 | 1200×770×960 | |
| 400 | or | 665 | 3590 | 1.1 | 660×660 | 1190×770×980 | |
| 500 | Dyn11 | 790 | 4390 | 1.1 | 660×660 | 1220×770×1000 | |
| 630 | 910 | 5290 | 0.9 | 820×850 | 1370×960×1005 | ||
| 630 | 885 | 5365 | 0.9 | 820×850 | 1370×960×1005 | ||
| 800 | 1035 | 6265 | 0.9 | 820×900 | 1440×960×1030 | ||
| 1000 | 1205 | 7315 | 0.9 | 820×820 | 1500×960×1045 | ||
| 1250 | 1420 | 8720 | 0.9 | 6.0 | 820×820 | 1550×960×1095 | |
| 1600 | 1665 | 10555 | 0.9 | 820×1070 | 1620×1200×1195 | ||
| 2000 | 2075 | 13005 | 0.7 | 820×1070 | 1730×1200×1390 | ||
| 2500 | 2450 | 15445 | 0.7 | 1070×1070 | 1780×1200×1430 |
SCB18 SERIES EPOXY RESIN CAST DRY TYPE TRANSFORMER
The main technical parameters
| Ratedcapacity(kVA) | Connectiongrouplabel | No-loadloss( W) | Load lossClass F (W) | No-loadcurrent(%) | Short circuitimpedance(%) | Mountingdimensions(mm) | Overalldimensions(mm) LXWXH |
| 30 | 105 | 640 | 2.3 | 400×400 | 880×660×800 | ||
| 50 | 155 | 900 | 2.2 | 400×400 | 910×660×860 | ||
| 80 | 210 | 1240 | 1.7 | 400×400 | 970×660×950 | ||
| 100 | 230 | 1415 | 1.7 | 400×400 | 980×660×975 | ||
| 125 | 270 | 1665 | 1.5 | 550×550 | 1030×660×985 | ||
| 160 | 310 | 1915 | 1.5 | 550×550 | 1070×660×1000 | ||
| 200 | 360 | 2275 | 1.3 | 550×550 | 1130×660×1055 | ||
| 250 | 415 | 2485 | 1.3 | 550×550 | 1150×660×1060 | ||
| 315 | Yyn0 | 510 | 3125 | 1.1 | 660×660 | 1200×770×960 | |
| 400 | or | 570 | 3590 | 1.1 | 660×660 | 1190×770×980 | |
| 500 | Dyn11 | 670 | 4390 | 1.1 | 660×660 | 1220×770×1000 | |
| 630 | 775 | 5290 | 0.9 | 820×850 | 1370×960×1005 | ||
| 630 | 750 | 5365 | 0.9 | 820×850 | 1370×960×1005 | ||
| 800 | 875 | 6265 | 0.9 | 820×900 | 1440×960×1030 | ||
| 1000 | 1020 | 7315 | 0.9 | 820×820 | 1500×960×1045 | ||
| 1250 | 1205 | 8720 | 0.9 | 6.0 | 820×820 | 1550×960×1095 | |
| 1600 | 1415 | 10555 | 0.9 | 820×1070 | 1620×1200×1195 | ||
| 2000 | 1760 | 13005 | 0.7 | 820×1070 | 1730×1200×1390 | ||
| 2500 | 2080 | 15445 | 0.7 | 1070×1070 | 1780×1200×1430 |
SCBH15 SERIES NON-METALLIC DRY-TYPE TRANSFORMER
Product overview
Amorphous alloy is an advanced old acute cooling technology, iron, cobalt, boron, silicon and other liquid melt injection into a high speed chassis and sharp cooling, forming 0.02mm0.04mm thin band, which has excellent soft viscosity performance, corrosion resistance, wear resistance and high resistance and other characteristics. The amorphous alloy core and cold rolled grain tend to silicon steel shee thave the following advantages:1. Amorphous alloy material has no crystal structure, and it is an isotropic softmagnetic material with low magnetization power.2. There is no structural defects that hinder the movement of the magnetic domain wall and the hysteresis loss is smaller than that of the silicon steel sheet.3. The resistivity is very high, which is 3-6 times that of silicon steel sheet. its eddy current loss is greatly reduced, and the unit eddy current loss is only 20%\~30% of that of siliconsteel sheet. SCBH15 Series amorphous alloy dry-type transformer is a new type of low-lossand energy-saving distribution transformer. This productcombines the technical advantages of the amorphous alloy transformer and thetraditional epoxy resin cast dry type transformer, and adopts a new structural form so thatit has the outstanding characteristics of low loss, especially the no-loadloss, which is 70% lower than the conventional 10 series dry type transformer. The productalso has the characteristics of compact structure, beautiful shape, lownoise, low temperature rise, strong overload capacity, stable electrical performanceconvenient maintenance and so on
Service condttion
1. The altitude is not 1000m (when more than 1000m).
2. Ambient temperature: maximum temperature + 40°C, hottest monthly average temperature +
30°C; 1owest temperature-25°C,hottest annual average temperature + 20°C
3. waveform of power supply voltage is similar to sine wave; three-phase power supply voltage is roughly symmetrical
4. installed in the household, the use of the environment without obvious pollution.
SCBH15 SERIES NON-METALLIC DRY-TYPE TRANSFORMER
Product characteristics
SCBH15 Series amorphous alloy dry transformer has low no-load loss, no oil, flame retardant since extinguishing, moistureresistance and maintenance free advantages, now all places of ordinary dry transformer are suitable for amorphous alloytrans former (including airport, station, city subway, high-rise buildings and power plants, etc.), especially in the flammableexplosive and power shortage is more suitable. The specific characteristics are:1, low consumption and energy saving: using isotropic soft magnetic conductive materials, small magnetization power,high resistivity, low eddy current loss. The core no-load loss and no-load current made of non-quality alloy materials arevery low, only 1 / 3 of the silicon steel sheet. The no-load loss of the transformer is reduced by 75% compared with thespecified value of GB / T10228. Can greatly reduce the operation cost, the energy-saving effect is remarkable.2. Strong corrosion resistance: the amorphous alloy core is fully packaged through resin and high temperature resistantsilicone gel, effectively prevent corrosion and amorphous alloy debris off, so as to effectively protect the core and coil.3. Low noise. in order to reduce the operating noise of the product, reasonable working maqnetic density is selected in theproduct design, the core and coil structure are improved in the product processing, and special noise reduction materialsare adopted, etc. The product noise is far lower than the reguirements of the national standard J8 /T10088.4. Strong short circuit resistance, the product adopts three-phase three-column structure around the core with compactand reasonable structure5, low temperature rise, long service life: the product low temperature rise, strong heat dissipation capacity, under forcedair cooling conditions can be 150% rated load operation, the performance of the temperature control protection systemcan be optional, to provide reliable quarantee for the safe operation of the transformer.
Model Meaning
SCBH15 SERIES NON-METALLIC DRY-TYPE TRANSFORMER
Main technical parameters
| Ratedcapacity(kVA) | Voltage groupus | ConnectiongroupLabel | No-loadloss( W) | Load loss Class F(W) | No-loadcurrent% | Short circuitimpedance % | ||||
| Highvoltage(kv) | Highvoltage | Lowpressure | 100 | 120℃(F) | 145℃(H) | |||||
| 30 | 70 | 670 | 710 | 760 | 1.6 | |||||
| 50 | 90 | 940 | 1000 | 1070 | 1.4 | 4.0 | ||||
| 80 | 120 | 1290 | 1380 | 1480 | 1.3 | |||||
| 100 | 130 | 1480 | 1570 | 1690 | 12 | |||||
| 125 | 150 | 1740 | 1850 | 1980 | 1.1 | |||||
| 160 | 170 | 2000 | 2130 | 2280 | 1.1 | |||||
| 200 | 200 | 2370 | 2530 | 2710 | 1.0 | |||||
| 250 | 230 | 2590 | 2760 | 2960 | 1.0 | |||||
| 315 | 280 | 3270 | 3470 | 3730 | 0.9 | |||||
| 400 | 6;6.3; | 310 | 3750 | 3990 | 4280 | 0.8 | ||||
| 500 | 6.6; | +2x2.5%; | Dyn11 | 360 | 4590 | 4880 | 5230 | 0.8 | ||
| 630 | 10; | Or±5%; | 420 | 5530 | 5880 | 6290 | 0.7 | |||
| 630 | 410 | 5610 | 5960 | 6400 | 0.7 | |||||
| 800 | 480 | 6550 | 6960 | 7460 | 0.7 | 6.0 | ||||
| 1000 | 550 | 7650 | 8130 | 8760 | 0.6 | |||||
| 1250 | 650 | 9100 | 9690 | 10370 | 0.6 | |||||
| 1600 | 760 | 11050 | 11730 | 12580 | 0.6 | 8.0 | ||||
| 2000 | 1000 | 13600 | 14450 | 15560 | 0.5 | |||||
| 2500 | 1200 | 16150 | 17170 | 18450 | 0.5 | |||||
| 1600 | 760 | 12280 | 12960 | 13900 | 0.6 | |||||
| 2000 | 1000 | 15020 | 15960 | 17110 | 0.5 | |||||
| 2500 | 1200 | 17760 | 18890 | 20290 | 0.5 | |||||
SG(B)10-100 -2500/10 SERIES H CLASS INSULATED 3-PHASE DRY TYPE TRANSFORMER
Scope of application
This series of products is our company with reference to the German MORA technology independent development of high-performance, high safety, environmental protection type dry transformer, it is suitable for high fire requirements, large load fluctuations and dirty wet harsh environment. Such as: airports, power plants, metallurgical operations, hospitals, high-rise buildings, shopping centers, densely populated areas and petrochemical, nuclear power plants, nuclear submarines and other special environment.
Model Meaning
Executive standard
1,GB1094.11-2007 dry power transformer.
2,GB/T10228-2015 dry type power transformer technical parameters and requirements.
3,GB/T17211-1998 dry power transformer load guide.
4,GB10237-1998 power transformer insulation level and insulation test.
5,GB4028-1993 shell protection grade (IP code).
6,JB/T10008-19986\~220kVtransformer sound 1evel.
7,JB/T56009-1998 dry power transformer product quality grade.
Performance characteristics
1, good heat dissipation, long heat life, strong load capacity, no forced air cooling under longterm load, IP45 conditions, can run at full load for a long time.
2, extremely high safety and flame retardant performance, no smoke is produced at 800°C high temperature for a long time burning.
3, strong thermal shock resistance (can immediately add full load at - { * } 5 0 ~ ^ { \circ } { C } )
4, 100% waterproof sealing, excellent hydrophobicity, moisture resistance.
5, the unique coil structure and strong field calculation, so that the product is almost no release.
6, low loss, energy-saving effect is significant, compared with SC9 series dry transformer no-load loss decreased by an average of 10%, load loss decreased by 5%.
7, after the life period can easily separate the insulation material and copper wire recycling, no pollution to the environment.
SG(B)10- 100 -2500/10 SERIES H CLASS INSULATED THREE PHASE DRY TYPE TRANSFORMERS
Structural characteristics
Technical parameters of epoxy resin cast dry type transformer (NewNX2)
1, unique porcelain insulation structure, using MORA company insulation cylinder and highfrequency ceramic pad block, never deformed.
2. The high and low coils are first made of NOMEX insulation material, and repeatedly impregnated with specially formulated H-class insulation by VPI vacuum pressure equipment. After baking for many times, the coils are sealed with external high-strength insulation material and cured at high temperature. The high voltage coil adopts the continuous structure with high mechanical strength and good heat dissipation conditions.
3, The iron core is made of imported high quality silicon steel sheet with high magnetic permeability. The stepping type 45° full incline structure is adopted. The winding and iron core are flexibly fixed, so that the transformer has low no-load loss and noise. The surface of the iron core is treated by a special process. The iron core is moderately clamped by the pull screw, the upper and lower clamps are connected by the pull plate and the base, the winding is fixed as one, the winding is fixed by the elastic pad, the buffer structure can reduce the vibration degree of the winding and reduce the noise. 4, The lead terminal is fixed in the upper part of the winding, the tap is in the middle of the winding, and the low voltage wire terminal is a plate conductive bar and adopts cold pressure welding.
The main technical parameters
SG(B)10-315-2500/10 series H class insulated three phase dry type power transformer technical parameters
| Ratedcapacity(kVA) | Voltage Combination | No- | LoadLoss(W) | No-loadCurrent(%) | ShortcircuitImpedance(%) | Weight(kg) | GaugeAxB(mm) | Outer shapeinches(mm)LxW×H | Outerdimensionswith enclosure(mm)LxW×H | |||
| Highvoltage(kV) | Tapping | Lowvoltage(kV) | Con-nectinggroupLabel | loadLoss(W) | ||||||||
| 100 | 480 | 1880 | 700 | 660×400 | 980×500×920 | 1340×900×1150 | ||||||
| 160 | 560 | 2700 | 750 | 660×400 | 1020×500×960 | 1400×900×1200 | ||||||
| 200 | 620 | 3100 | 880 | 660×400 | 1050×500×1150 | 1450×900×1400 | ||||||
| 250 | 760 | 3850 | 4 | 1050 | 660×400 | 1090×500×1310 | 1450×900×1550 | |||||
| 315 | 880 | 4600 | 1380 | 660×660 | 1240×770×1355 | 1600×1100×1600 | ||||||
| 400 | 6; | 1040 | 5400 | 1750 | 820×820 | 1310×960×1390 | 1700×1100×1650 | |||||
| 500 | 6.3;6.6; | ±5%or | 0.4 | Yyn0 | 1200 | 6600 | 1880 | 820×820 | 1370×630×1400 | 1750×1100×1700 | ||
| 630 | 10; | ±2× | orDyn11 | 1340 | 8050 | 1.4 | 1950 | 820×820 | 1400×960×1445 | 1800×1250×1750 | ||
| 800 | 10.5;11; | 2.5%; | 1690 | 9500 | 2200 | 820×820 | 1470×960×1495 | 1850×1250×1800 | ||||
| 1000 | 19801 | 1400 | 2490 | 820×820 | 1510×960×1505 | 1900×1250×1800 | ||||||
| 1250 | 23801 | 2500 | 1.2 | 6 | 3050 | 1070×10701 | 620×1255×1585 | 2000×1300×1850 | ||||
| 1600 | 27301 | 4900 | 369010 | 70×10701 | 660×1588×1675 | 2050×1300×2000 | ||||||
| 2000 | 33201 | 7500 | 1.0 | 4400 | 1070×1070 1 | 730×1255×1840 | 2100×1350×2150 | |||||
| 2500 | 40002 | 0300 | 4940 1 | 070×10701 | 780×1288×1930 | 2150×1350×2200 | ||||||
S11, S11-M SERIES LOW LOSS AND ENERGY SAVING DISTRIBUTION TRANSFORMER
Scope of application
S11-M series oil-immersed transformer can be widely used in high-rise buildings, commercial centers, subways, airports, stations, industrial and mining enterprises, drilling platforms, oil platforms, especially suitable for flammable, explosive and other fire protection requirements and harsh environment places. It can also be used in residential areas, commercial streets, industrial and mining enterprises and rural power and lighting.
Structural features
S11-M series oil-immersed transformer adopts high quality grain orientation cold rolled silicon steel sheet iron core, all inclined non-hole binding structure, the iron core is multi-level step shape, three joints or five joints, low air loss, low noise; Coil: the use of high quality QQ lacquer coated round copper wire, oxygen free copper rod drawn flat copper money or copper knot wound, its form has cylinder type, continuous type, new screw type, split type, etc., with enough electrical strength, mechanical strength and heat dissipation capacity. Fuel tank: The use of high quality steel plate welded, elliptic, rectangular and other structures, cooling elements using chip radiator, expansion heat dissipator or corrugated oil tank, the tank in the factory for reliable sealing test, the internal and external surface after pickling, phosphating treatment, three bottom side paint coating, both corrosion resistance and beautiful.
The main technical parameter number
| Rated | Voltage combination | No-loadloss(W) | LoadLoss(W) | No-loadcurrent(%) | Shortcircuitimpedance(%) | Gauge AxB(mm) | |||
| capacity(kVA) | Highvoltage(kV) | High voltagetap range | Lowvoltage(kV) | Connectiongrouplabel | |||||
| 30 | 100 | 690/660 | 2.1 | 450×450 | |||||
| 50 | 130 | 1010/960 | 2.0 | 450×450 | |||||
| 63 | 150 | 1200/1150 | 1.9 | 450×450 | |||||
| 80 | 180 | 1440/1370 | 1.8 | 450×450 | |||||
| 100 | 200 | 1730/1650 | 1.6 | 450×450 | |||||
| 125 | 240 | 2080/1980 | 1.5 | 450×450 | |||||
| 160 | 290 | 2540/2420 | 1.4 | 5.5 | 550×550 | ||||
| 200 | 340 | 3000/2860 | 1.3 | 550×550 | |||||
| 250 | ±5%; | Yyn0 | 400 | 3520/3350 | 1.2 | 550×550 | |||
| 315 | 20 | or | 0.4 | or | 480 | 4210/4010 | 1.1 | 550×550 | |
| 400 | ±2×2.5% | Dyn11 | 570 | 4970/4730 | 1.0 | 550×550 | |||
| 500 | 680 | 5940/5660 | 1.0 | 550×550 | |||||
| 630 | 810 | 6820 | 0.9 | 820×820 | |||||
| 800 | 980 | 8250 | 0.8 | 820×820 | |||||
| 1000 | 1150 | 11330 | 0.7 | 820×820 | |||||
| 1250 | 1380 | 13200 | 0.7 | 820×820 | |||||
| 1600 | 1660 | 15950 | 0.6 | 820×820 | |||||
| 2000 | 1950 | 19140 | 0.6 | 1070×1070 | |||||
| 2500 | 2340 | 22220 | 0.5 | 1070×1070 | |||||
S11, S11-M SERIES LOW LOSS AND ENERGY SAVING DISTRIBUTION TRANSFORMER
35kV class SZ11 series no excitation voltage regulation power transformer technical parameters
| Ratedcapacity(kVA) | Voltage combination | No-loadLoss(W) | loadLoss(W)C | No-loadurrentt(%) | ShortcircuitImpedance(%) | Gauge AxB(mm) | Weight (kg) | |||||
| Highvoltage(kv) | Highvoltagetap range | LowCvoltage(kv) | onnectiongrouplabel | Bodyweightoil | Insulationweightw | Totaleight | ||||||
| 2000 | 2300 | 19200 | 0.5 | 6.5 | 1070×1070 | 2800 | 1900 | 6800 | ||||
| 2500 | 2720 | 20600 | 0.5 | 1070×1070 | 3350 | 2100 | 7500 | |||||
| 3150 | Yd11 | 3230 | 24700 | 0.5 | 1070×1070 | 3720 | 2250 | 8580 | ||||
| 4000 | 3870 | 29100 | 0.5 | 7.0 | 1070×1070 | 4375 | 2900 | 10345 | ||||
| 5000 | 4.64 | 34200 | 0.5 | 1475×1475 | 4900 | 3100 | 11200 | |||||
| 6300 | 5630 | 36700 | 0.5 | 1475×1475 | 6410 | 3300 | 12280 | |||||
| 8000 | 6.3; | 7870 | 40600 | 0.4 | 7.5 | 1475×1475 | 8390 | 3610 | 17150 | |||
| 10000 | 35; | ±3×2.5 | 6.6; | 9280 | 48000 | 0.4 | 1475×1475 | 9150 | 4720 | 19740 | ||
| 12500 | 38.5 | 10.5; | Ynd11 | 10970 | 56800 | 0.35 | 1475×1475 | 11340 | 5010 | 21400 | ||
| 16000 | 11; | 13100 | 70300 | 0.35 | 8.0 | 2040×2040 | 13410 | 5200 | 25630 | |||
| 20000 | 15500 | 82700 | 0.3 | 2040×2040 | 15740 | 5960 | 28680 | |||||
| 25000 | 18300 | 97800 | 0.3 | 10 | 2040×2040 | 17055 | 6620 | 33500 | ||||
| 31500 | 218001 | 16000 | 0.3 | 2040×2040 | 21800 | 9400 | 43020 | |||||
| Ratedcapacity(kVA) | Voltage combination | No-loadLoss(W) | LoadLoss(w) | No-loadElectriccurrent(%) | Short circuitImpedance(%) | GaugeA×B (mm) | Weight (kg) | |||||
| Highvoltage(kv) | highvoltagetap Range | Lowvoltagegroup(kv) | Connectionlabel | Bodyweightoil | Insulationweight | Totalweight | ||||||
| 50 | 160 | 1200/1140 | 1.3 | 450x450 | 233 | 263 | 827 | |||||
| 100 | 2302 | 010/1910 | 1.1 | 450x450 | 348 | 310 | 827 | |||||
| 125 | 2702 | 370/2260 | 1.1 | 450x450 | 406 | 340 | 1037 | |||||
| 160 | 280 | 2820/2680 | 1.0 | 450x450 | 496 | 350 | 1110 | |||||
| 200 | 3403 | 320/3160 | 1.0 | 450x450 | 557 | 370 | 1200 | |||||
| 250 | 4003 | 950/3760 | 0.95 | 550x550 | 646 | 400 | 1360 | |||||
| 315 | 480 | 4750/4530 | 0.95 | 550x550 | 771 | 450 | 1620 | |||||
| 400 | 35; | ±2 | 0.4 | Yyn0or | 5805 | 740/5470 | 0.85 | 6.5 | 550x550 | 890 | 500 | 1850 |
| 500 | 38.5 | × 2.5%; | Dyn11 | 6806 | 910/6580 | 0.85 | 550x550 | 1070 | 560 | 2140 | ||
| 630 | 830 | 7860 | 0.65 | 550x550 | 1245 | 610 | 2420 | |||||
| 800 | 980 | 9400 | 0.65 | 820x820 | 1450 | 670 | 2710 | |||||
| 1000 | 1150 | 11500 | 0.65 | 820x820 | 1665 | 760 | 3280 | |||||
| 1250 | 1400 | 13900 | 0.6 | 820x820 | 1910 | 810 | 3560 | |||||
| 1600 | 1690 | 16600 | 0.6 | 820x820 | 2187 | 890 | 4060 | |||||
| 2000 | 1990 | 19700 | 0.55 | 1070x1070 | 2720 | 1059 | 5161 | |||||
| 2500 | 2360 | 23200 | 0.55 | 1070x1070 | 3236 | 1143 | 5912 | |||||
S11, S11-M SERIES LOW LOSS AND ENERGY SAVING DISTRIBUTION TRANSFORMER
| Rated | Voltage combination | No-loadloss(W) | LoadLoss(W) | No-loadCurrent(%) | ShortcircuitImpedance(%) | GaugeA×B(mm) | Weight (kg) | |||||
| capacity | Highvoltage(kv) | highvoltagetap Range | Lowvoltage(kv) | Connectiongrouplabel | Activepartweight | Insulatedoilweight | TotalWeight | |||||
| (kVA) | ||||||||||||
| 30 | 100 | 630/600 | 1.5 | 400×400 | 135 | 65 | 253 | |||||
| 50 | 130 | 910/870 | 1.3 | 400×400 | 210 | 75 | 335 | |||||
| 63 | 1501 | 090/1040 | 1.2 | 400×400 | 235 | 90 | 435 | |||||
| 80 | 180 | 1310/1250 | 1.2 | 400×450 | 270 | 95 | 450 | |||||
| 100 | 200 | 1580/1500 | 1.1 | 400×450 | 338 | 101 | 515 | |||||
| 125 | 2401 | 890/1800 | 1.1 | 4.0 | 400×450 | 375 | 115 | 600 | ||||
| 160 | 2802 | 310/2200 | 1.0 | 550×550 | 465 | 125 | 695 | |||||
| 200 | 6 | 3402 | 730/2600 | 1.0 | 550×550 | 538 | 152 | 840 | ||||
| 250 | 6.3 | ±2×2.5%; | Yyn0 | 4003 | 200/3050 | 0.9 | 550×550 | 610 | 171 | 990 | ||
| 315 | 10 | or | 0.4 | or | 4803 | 830/3650 | 0.9 | 550×550 | 733 | 189 | 1116 | |
| 400 | 10.5 | ±5%; | Dyn11 | 5704 | 520/4300 | 0.8 | 550×550 | 862 | 220 | 1357 | ||
| 500 | 11 | 6805 | 410/5150 | 0.8 | 550×550 | 1078 | 269 | 1596 | ||||
| 630 | 810 | 6200 | 0.6 | 660×660 | 1140 | 280 | 1690 | |||||
| 800 | 980 | 7500 | 0.6 | 820×820 | 1260 | 310 | 2050 | |||||
| 1000 | 1150 | 10300 | 0.6 | 4.5 | 820×820 | 1410 | 375 | 2565 | ||||
| 1250 | 1360 | 12000 | 0.5 | 820×820 | 1705 | 490 | 2950 | |||||
| 1600 | 1640 | 14500 | 0.5 | 820×820 | 2031 | 614 | 3569 | |||||
| 2000 | 1940 | 18300 | 0.4 | 820×820 | 2361 | 790 | 4108 | |||||
| 2500 | 2290 | 21200 | 0.4 | 1070×1070 | 2837 | 860 | 4960 | |||||
SH(B)15 SERIES AMORPHOUS ALLOYDISTRIBUTION TRANSFORMERS
Product overview
SH(B)15 series products comply with the national standard GB1094 "Power transformer" and JB/T10318-2002 "Oil immersed amorphous alloy iron core distribution transformer technical parameters and requirements" Amorphous alloy iron core transformer is a new type of environmental protection and energy saving products, the iron core is coiled with amorphous alloy strip. The no-load loss is more than 75% lower than the current S11 type distribution transformer.
Structural features
• Amorphous alloy is a new type of strip, its material does not have a crystal structure, small magnetizing power, high electronic rate, so the eddy current loss is small, with this material as the core can produce a new type of energy-saving transformer, is the ideal product for the replacement of the distribution network.
• The core is a coil core structure, three-phase five-column type, and the cross-section is rectangular.
• The coil is rectangular, the high voltage is wound with acetal enamelled wire, and the low voltage is made of oxygen-free copper wire or copper foil coil, which increases the transformer's ability to withstand short circuit. The transformer connection group adopts Dyn11 to avoid the influence of high order harmonics and has strong resistance to unbalanced load. Significantly improve the quality of power supply.
SH(B)15 SERIES AMORPHOUS ALLOYDISTRIBUTION TRANSFORMERS
The Main Technical Parameter Number
| Rated | Voltage combination | No-loadloss(W) | LoadLoss(W) | No-loadShortCurrent(%) | circuit | Weight (kg) | GaugeAxB (mm) | Overalldimensions(mm) LxWxH | |||||
| capacity(kVA) | Highvoltage(kv) | highvoltagetap Range | Lowvoltage(kv) | Connectionre | Impedance(%) | Activepartoilweight | Insulatedweight | TotalWeight | |||||
| 30 | 33 | 600 | 1.7 | 225 | 100 | 420 | 550×550 | 986×860×810 | |||||
| 50 | 43 | 870 | 1.3 | 305 | 120 | 535 | 550×550 | 1016×810×840 | |||||
| 63 | 6 | ±2 | 50 | 1040 | 1.2 | 350 | 130 | 595 | 550×550 | 1056×820×865 | |||
| 80 | 6.310 | ×2.5%; | 0.4 | Dyn11 | 60 | 1250 | 1.1 | 405 | 135 | 660 | 550×550 | 1044×865×860 | |
| 100 | 10.5 | or | 75 | 1500 | 1.0 | 430 | 155 | 770 | 550×550 | 1110×880×815 | |||
| 125 | 11 | 85 | 1800 | 0.9 | 500 | 165 | 860 | 550×550 | 1146×880×950 | ||||
| 160 | 100 | 2200 | 0.7 | 595 | 185 | 990 | 550×550 | 1206×880×985 | |||||
| 200 | 120 | 2600 | 0.7 | 675 | 205 | 1110 | 660×660 | 1266×895×1015 | |||||
| 250 | 140 | 3050 | 0.7 | 810 | 220 | 1275 | 660×660 | 1310×950×1060 | |||||
| 315 | 170 | 3650 | 0.5 | 945 | 245 | 1475 | 660×660 | 1365×835×1105 | |||||
| 400 | 200 | 4300 | 0.5 | 1195 | 280 | 1835 | 660×820 | 1310×1030×1195 | |||||
| 500 | 66.3 | ±2 | 240 | 5150 | 0.5 | 1375 | 335 | 2130 | 660×820 | 1385×1125×1195 | |||
| 630 | 10× | 2.5%;or | 0.4 | Dyn | 11320 | 6200 | 0.3 | 1610 | 470 | 2605 | 660×820 | 1505×1305×1295 | |
| 800 | 10.511 | ±5%; | 380 | 7500 | 0.3 | 1910 | 575 | 3090 | 820×10701 | 900×1175×1395 | |||
| 1000 | 450 | 10300 | 0.3 | 2130 | 670 | 3570 | 820×10702 | 115×1275×1420 | |||||
| 1250 | 5 | 30 1 | 2000 | 0.3 | 4.5 | 2510 | 710 | 4140 | 820×10702 | 140×1490×1440 | |||
| 1600 | 6301 | 4500 | 0.3 | 3045 | 820 | 4950 | 820×1070 23 | 05×1560×1530 | |||||
S13-M.ZT SERIES INTELLIGENT ON-LOAD CAPACITOR TRANSFORMER
Product overview
Intelligent on-load regulating transformer has two capacity positions, which can automatically adjust the capacity operation according to the change of load without power failure. When the load is light or close to no load, the transformer is adjusted from large capacity to small capacity operation, which not only greatly reduces the no-load loss, but also overcomes the trouble of manual operation of power failure without load regulating capacity, and really achieves the purpose of energy saving and intelligence. The product is especially suitable for seasonal load change amplitude of the rural power grid, day and night load change of significant residential areas, street light change, urban business district, part-time industrial area and oil field pumping unit distribution change, but also suitable for load change larger 35kV power transformer. The intelligent on-load regulating transformer developed by our company has a number of patents, which is mainly composed of the transformer, the on-load regulating switch and the control box installed with the on-load regulating controller. Its data storage, remote communication, remote control, remote regulation, telemetry, intelligent networking, reactive power compensation control, anti-theft and other functions, are unmatched by traditional coil core, amorphous transformer and other energy-saving products.
The mode and meaning
| Model | Voltage combina- tion (kV) | Coupling group | No-load loss (W) | Load loss (W) | Short circuit impedance (%) | No-load current (%) |
| S11-M-ZT-160(50) | 10/0.4> | Dyn11 Yyn0 | 200(100) | 2310(870) | 4.0 | 0.8 (1.6) |
| S11-M-ZT-200(63) | 240(110) | 2730(1040) | 4.0 | 0.7 (1.5) | ||
| S11-M-ZT-250(80) | 400(180) | 3200(1250) | 4.0 | 0.7 (1.4) | ||
| S11-M-ZT-315(100) | 480(200) | 3830(1500) | 4.0 | 0.7 (1.4) | ||
| S11-M-ZT-400(125) | 570(240) | 4520(1800) | 4.0 | 0.6 (1.3) | ||
| S11-M-ZT-500(160) | 680(280) | 5410(2200) | 4.0 | 0.6 (1.2) | ||
| S11-M-ZT-630(200) | 810(340) | 6200(2600) | 4.5 | 0.5 (1.1) |
S13-M.ZT SERIES INTELLIGENT ON-LOAD CAPACITOR TRANSFORMER
Energy efficiency analysis
Annual operating costs and investment recovery period:
Cy=[8600x(P0+0.05xIoxSN/100)+2200x(Pk+0.05xUKxSN/100)]x0.5 In the above formula, Cy is the annual operating cost of the transformer, yuan;
Cy=[8600x(P0+0.05xIoxSN/100)+2200x(Pk+0.05xUKxSN/100)]x0.5
P0 is no-load loss, kw;
Pk is the load loss, kw;
SN is the rated capacity, kVA;
Uk is the percentage of short-circuit impedance, %;
Io is the percentage of no-load current, %;
0.5 is the electricity price, yuan /(kWh);8600 and 2200 are variable voltage respectively, and Qload, equivalent full load (load factor 0.5) hours are based on the above formula and related performance indicators.The annual operating cost of SII-M-ZT series intelligent distribution transformer with capacity and S1 type ordinary three-phase oil-immersed distribution transformer is calculated. It is assumed that the on-load capacitor transformer operates in high capacity mode for 3 months of the year.according to the distribution transformer corresponding technical parameters calculated, the specific data are shown in Table 3.
The on-load capacitor-regulating transformer ADAPTS to the development direction of energy saving, intelligence, high efficiency and stable power supply quality in the field of power transformation. It can automatically change the rated output capacity of the terminal distribution transformer by tracking the load change, and ensure the power supply in a timely and appropriate manner, thus greatly reducing the no-load loss of the transformer by about 40%\~50%, which can improve the power factor of the grid.Reduce the reactive power component in the distribution network, reduce the network loss, reduce the capacity of power capacitance, open up a new way for the development of energy saving distribution network, and bring good economic benefits to the society.
| Capacity(kVA) | Annual operatingcost of distributiontransformerwith on-loadcapacity regulation(Yuan) | Annual operatingcost of ordinarydistributiontransformer (Yuan) | Annual operatingcost reducedAmount (Yuan) | Annual operatingcost reduction (%) |
| 160(50) | 2289 | 4647 | 2358 | 51 |
| 200(63) | 2710 | 5550 | 2840 | 51 |
| 250(80) | 3227 | 6543 | 3316 | 51 |
| 315(100) | 3816 | 7918 | 4102 | 52 |
| 400(125) | 4588 | 9531 | 4943 | 52 |
| 500(160) | 5497 | 11265 | 5768 | 51 |
| 630(200) | 6608 | 13352 | 6744 | 51 |
S13-M.ZT SERIES INTELLIGENT ON-LOAD CAPACITOR TRANSFORMER
Appearance drawing and mounting dimensions
10kV intelligent on-load adjustable capacity distribution transformer outline
| Capacity(KVA) | Overall dimensions (mm) | Mountingdimensions (mm) | Weight (kg) | |||
| Length L | Wide B | High H | L2 | B2 | ||
| 160(50) | 1380 | 990 | 1230 | 820 | 820 | 1100 |
| 200(63) | 1400 | 1070 | 1230 | 820 | 820 | 1220 |
| 250(80) | 1440 | 1120 | 1250 | 820 | 820 | 1370 |
| 315(100) | 1480 | 1170 | 1350 | 820 | 820 | 1620 |
| 400(125) | 1620 | 1190 | 1330 | 820 | 820 | 1910 |
| 500(160) | 1710 | 1240 | 1350 | 820 | 820 | 2200 |
| 630(200) | 1850 | 1270 | 1450 | 820 | 820 | 2660 |
S11-M·RL N TYPE THREE-DIMENSIONAL COIL IRON CORE DISTRIBUTION TRANSFORMER
Product overview
S11 type three-dimensional coil iron core distribution transformer capacity range 30-2500KVA. The iron core is a three-phase three-column coil structure with internal and external frame. High degree of mechanization, lamination coefficient is large. The high and low pressure coils are wound continuously on the core column, the concentricity is good, and the coils are tight. The main technical and economic indicators have reached the international advanced level of the same kind of products.
The S11 series coil core distribution transformer has low loss, and the load loss is the same as the new S11 stack core distribution transformer. Compared with GB/ T6415-20081, its no-1oad loss is reduced by an average of 20%. The main material consumption is less and the weight is light The no-load current is small, and the magnetic flux is completely along the lattice arrangement direction of the cold-rolled silicon steel sheet. Low noise, compared with JB/T10088-2004 standard value, about 3-5dB lower. Strong short-circuit resistance and high reliability. The clamp mainly plays the role of tightening the winding, and the iron yoke insulation and trapezoidal pad are integrated into one, so that the body is under uniform pressure.
Iron core: 30Q120 cold rolled silicon steel sheet. The inner and outer frame of the three-phase column is coil structure, and the core column is a multi-level stepped cylindrical cross-section. The core is annealed by true air after winding. Pull screw body of upper and lower clamp. The iron core surface is coated with epoxy resin, guaranteed
The iron core is not deformed or rusted.
Winding and body: low voltage winding for 1-6 wires and wound four layers (or double) cylinder type, using paper covered flat copper wire. The high voltage winding is multi-layer cylinder type, the impact distribution is good, and the high strength acetal enamelled round copper wire is used. The coil is wound directly on a rotating die consisting of a gear plate and a soft paper tube which is stuck on the iron core post. The yoke insulation and trapezoidal pad are integrated into one, so that the body is evenly compressed. A new type of hanging plate positioning structure, longitudinal and transverse positioning, to ensure that the body is stable and not displaced. Oil tank: mainly corrugated oil tank. It can also be designed as a rectangular chip radiator tank.
Model meaning
S11-M.ZT SERIES INTELLIGENT ON-LOAD CAPACITOR TRANSFORMER
Appearance drawing and mounting dimensions
| Voltage combination | No-loadloss(W) | LoadLoss(W) | No-loadCurrent(%) | Short | Weight (kg) | GaugeA x B (mm) | Overall dimensions(mm) LxW x H | ||||||
| Capacity(KVA) | High | highvoltagetap Range | Lowvoltage(kv) | Connectiongrouplabel | |||||||||
| voltage(kv) | |||||||||||||
| circuitImpedance(%) | ActiveInsulationpartoilweight | Allweight | upweight | ||||||||||
| 30 | 100 | 630/600 | 0.33 | 167 | 107 | 358 | 380×550 | 1010×667×1159 | |||||
| 50 | 130 | 910/870 | 0.30 | 222 | 113 | 423 | 380×550 | 1025×683×1224 | |||||
| 80 | 180 | 1310/1250 | 0.27 | 278 | 153 | 525 | 380×550 | 1114×727×1314 | |||||
| 100 | 200 | 1580/1500 | 0.26 | 278 | 149 | 554 | 380×550 | 1148×995×1314 | |||||
| 160 | 280 | 2310/2200 | 0.24 | 439 | 168 | 746 | 400×660 | 1045×905×1376 | |||||
| 200 | 340 | 2730/2600 | 0.23 | 509 | 197 | 856 | 400×660 | 1091×944×1394 | |||||
| 250 | 11; | 400 | 3200/3050 | 0.22 | 591 | 228 | 986 | 400×660 | 1114×965×1397 | ||||
| 315 | 10.5; | ±5%; | Dyn11;480 | 480 | 3830/3650 | 0.21 | 679 | 252 | 1124 | 550×820 | 1190×1031×1422 | ||
| 400 | 6.6; | ±2 | 0.4 Y | zn11 | 570; | 4520/4300 | 0.21 | 818 | 303 | 1340 | 550×820 | 1225×1060×1477 | |
| 500 | 6.3; | ×2.5%; | Yyn0; | 680 | 5140/5100 | 0.20 | 964 | 375 | 1618 | 550×820 | 1394×1207×1562 | ||
| 630 | 6; | 810 | 6200 | 0.20 | 1128 | 417 | 1939 | 550×820 | 1467×1270×1594 | ||||
| 800 | 980 | 7500 | 0.19 | 1424 | 526 | 2417 | 550×820 | 1570×1360×1636 | |||||
| 1000 | 11501 | 0300 | 0.18 | 1660 | 645 | 2955 5 | 50×1070 | 1731×1510×1656 | |||||
| 1250 | 13601 | 2000 | 0.17 | 4.5 | 1802 | 630 | 3135 | 550×1070 | 1761×1525×1768 | ||||
| 1600 | 16401 | 4500 | 0.16 | 2255 | 781 | 3784 5 | 50×1070 | 1740×1510×1928 | |||||
| 2000 | 22501 | 8500 | 0.15 | 31661 | 239 | 5637 | 660×1300 | 1836×1699×1863 | |||||
| 2500 | 24002 | 4000 | 0.15 | 31581 | 541 | 6089 | 660×1300 | 1856×1762×2088 | |||||
S13-M·RL D THREE-DIMENSIONAL COILIRON CORE DISTRIBUTION TRANSFORMER
Product overview
S13 type three-phase coil iron core distribution transformer capacity range 30-2500KVA. The iron core is a three-phase three-column coil structure with internal and external frame. High degree of mechanization, lamination coefficient is large. The high and low pressure coils are wound continuously on the core column, the concentricity is good, and the coils are tight. The main technical and economic indicators have reached the international advanced level of the same kind of products.
The S13 series coil core distribution transformer has low loss, and the load loss is the same as the new S11 stack core distribution transformer. Same as GB/T6415-2008
1, its no-load loss has been reduced by an average of 20%. The main material consumption is less and the weight is light. The no-load current is small, and the magnetic flux is completely along the lattice arrangement direction of the cold-rolled silicon steel sheet. Low noise, compared with JB/T10088-2004 standard value, about 3-5dB lower. Strong short-circuit resistance and high reliability. The clamp mainly plays the role of tightening the winding, and the iron yoke insulation and trapezoidal pad are integrated into one, so that the body is under uniform pressure. Iron core: 30Q120 cold rolled silicon steel sheet. The inner and outer frame of the three-phase column is coil structure, and the core column is a multi-level stepped cylindrical cross-section. The core is annealed by true air after winding. Pull screw body of upper and lower clamp. The iron core surface is coated with epoxy resin, guaranteed
The iron core is not deformed or rusted.
Winding and body: low voltage winding for 1-6 wires and wound four layers (or double) cylinder type, using paper covered flat copper wire. The high voltage winding is multi-layer cylinder type, the impact distribution is good, and the high strength acetal enamelled round copper wire is used. The coil is wound directly on a rotating die consisting of a gear plate and a soft paper tube which is stuck on the iron core post. The yoke insulation and trapezoidal pad are integrated into one, so that the body is evenly compressed. A new type of hanging plate positioning structure, longitudinal and transverse positioning, to ensure that the body is stable and not displaced.
Oil tank: mainly corrugated oil tank. It can also be designed as a rectangular chip radiator tank.
Model meaning
S13-M·RL D THREE-DIMENSIONAL COIL IRON CORE DISTRIBUTION TRANSFORMER
The main technical parameters
| Voltage combination | No-loadloss(W) | LoadLoss(W) | No-loadCurrent(%) | ShortcircuitImpedance(%) | Weight (kg) | GaugeA x B (mm) | Overall dimensions(mm) LxW x H | ||||||
| Capacity(KVA) | Highvoltage(kv) | highvoltagetap Range | Lowvoltage(kv) | Connectionr | Activepartoilweight | Insulationweight | All upweight | ||||||
| 30 | 80 | 630/600 | 0.30 | 178 | 113 | 377 | 380×550 | 1028×682×1199 | |||||
| 50 | 100 | 910/870 | 0.24 | 236 | 111 | 435 | 380×550 | 1025×683×1224 | |||||
| 80 | 130 | 1310/1250 | 0.22 | 313 | 146 | 553 | 380×550 | 1096×722×1314 | |||||
| 100 | 150 | 1580/1500 | 0.21 | 356 | 148 | 607 | 380×550 | 1096×722×1334 | |||||
| 160 | 200 | 2310/2200 | 0.19 | 4.0 | 484 | 185 | 797 | 400×660 | 1080×935×1441 | ||||
| 200 | 11; | 240 | 2730/2600 | 0.18 | 556 | 228 | 937 | 400×660 | 1109×960×1444 | ||||
| 250 | 10.5; | ±2 | Dyn11;290 | 290 | 3200/3050 | 0.17 | 655 | 263 | 1091 | 400×660 | 1196×1036×1457 | ||
| 315 | 6.6; | or | 0.4Y | zn11 | 340; | 3830/3650 | 0.16 | 769 | 274 | 1269 | 550×820 | 1276×1105×1467 | |
| 400 | 6.3; | ±5%; | Yyn0; | 410 | 4520/4300 | 0.16 | 896 | 323 | 1437 | 550×820 | 1306×1131×1542 | ||
| 500 | 6; | 480 | 5140/5100 | 0.16 | 1044 | 433 | 1872 | 550×820 | 1483×1284×1592 | ||||
| 630 | 570 | 6200 | 0.15 | 1352 | 414 | 2085 | 550×820 | 1395×1210×1649 | |||||
| 800 | 700 | 7500 | 0.15 | 1613 | 496 | 2481 | 550×820 | 1526×1321×1711 | |||||
| 1000 | 830 1 | 0300 | 0.14 | 4.5 | 1703 | 656 | 3000 | 550×1070 | 1717×1487×1726 | ||||
| 1250 | 970 | 12000 | 0.13 | 2065 | 702 | 3449 | 550×1070 | 1711×1482×1829 | |||||
| 1600 | 11701 | 4500 | 0.12 | 2592 | 1045 | 4450 | 550×1070 | 1880×1628×1938 | |||||
The main technical parameters
| Voltage combination | No-loadloss(W) | LoadLossC(W) | No-loadurrentt(%) | ShortcircuitImpedance(%) | Weight (kg) | GaugeA x B (mm) | Overall dimensions(mm) LxW x H | ||||||
| Capacity(KVA) | Highvoltage | highvoltagetap Range | Lowvoltage(kv) | Connectiongrouplabel | Activepartweightoil | Insulationweight | All upweight | ||||||
| (kv) | |||||||||||||
| 30 | 80 | 630 | 2.1 | 150 | 75 | 320 | 400×400 | 730×480×950 | |||||
| 50 | 100 | 910 | 2.0 | 210 | 90 | 370 | 400×400 | 760×510×920 | |||||
| 63 | 110 | 1090 | 1.9 | 255 | 95 | 420 | 400×450 | 790×530×950 | |||||
| 80 | 130 | 1310 | 1.8 | 280 | 120 | 490 | 400×450 | 810×580×970 | |||||
| 100 | 150 | 1580 | 1.6 | 360 | 125 | 600 | 400×550 | 830×760×1160 | |||||
| 125 | 170 | 1890 | 1.5 | 4.0 | 410 | 135 | 690 | 400×550 | 990×620×1040 | ||||
| 160 | 200 | 2310 | 1.4 | 480 | 155 | 815 | 550×550 | 1070×680×1100 | |||||
| 200 | 6; | 240 | 2730 | 1.3 | 565 | 170 | 920 | 550×650 | 1170×770×1300 | ||||
| 250 | 6.3; | ±2×2.5%; | Yyn0 | 290 | 3200 | 1.2 | 665 | 200 | 1020 | 550×650 | 1230×820×1190 | ||
| 315 | 10; | 0.4 | or | 340 | 3830 | 1.1 | 750 | 230 | 1160 | 550×650 | 1295×865×1240 | ||
| 400 | 10.5; | ±5%; | Dyn11 | 410 | 4520 | 1.0 | 880 | 235 | 1385 | 550×750 | 1385×925×1250 | ||
| 500 | 11; | 480 | 5410 | 1.0 | 1100 | 260 | 1670 | 660×750 | 1560×1060×1360 | ||||
| 630 | 570 | 6200 | 0.9 | 1255 | 310 | 1920 | 660×750 | 1615×1105×1350 | |||||
| 800 | 700 | 7500 | 0.8 | 1585 | 465 | 2330 | 820×850 | 1725×1190×1390 | |||||
| 1000 | 830 | 10300 | 0.7 | 1720 | 510 | 2680 | 820×850 | 1820×1290×1440 | |||||
| 1250 | 970 | 12000 | 0.6 | 4.5 | 2075 | 625 | 2995 | 820×850 | 1860×1290×1540 | ||||
| 1600 | 1170 | 14500 | 0.6 | 2215 | 640 | 3610 | 820×850 | 1340×1700×1560 | |||||
| 2000 | 1360 | 18300 | 0.5 | 2965 | 805 | 4570 | 820×820 | 1660×1460×1850 | |||||
| 2500 | 1600 | 21200 | 0.5 | 3600 | 895 | 5335 | 1070×1070 | 1750×1780×1900 | |||||