Dear Customer, Thank you for purchasing an ORANS sauna. We hope you will be fully satisfied with your purchase. Please remember that this manual is an important document of reference and should be provided by the seller with the sauna. ORANS forbids the reproduction of any part of this manual. Each sauna is checked and tested thoroughly at our premises prior to delivery to ensure its correct working order and the absolute reliability of its safety devices. Should you require any further information or clarification, please contact your local dealer or contact our company directly.
TWOPEOPLEARENECESSARY!
It indicates a procedure for which two people are required. Otherwise, the product or other objects in the surroundings may be damaged.
W7
FOURPEOPLEARENECESSARY!
It indicates a procedure for which four people are required. Otherwise, the product or other objects in the surroundings may be damaged.
INSTALLERFORELECTRICALSUPPLIES
Technician specialised in installing the product in ordinary work conditions. He is competent for all the interventions concerning the electrical supplies such as registrations, maintenance and repairs. He is skilled for interventions in electrical boards or electrical outlets which are under power.
Electrical Sauna System compliancewith:
CSA Std. C22.2 No. 164-18 - Electric sauna heating equipment
UL Std. No.875 (14th edition) -Electric Dry-Bath Heaters Some information or pictures in this manual may show details and spare parts which may be slightly different from the ones of your Sauna room: however, the primary information remains unchanged. Following our constant search for improvements, the Sauna room may show some changes which are not included in this manual.
ORANS refuses all responsibility for damages caused by an inappropriateuse of the sauna.ORANSreserves the right to institute legal proceedings against those who make any changes to its Sauna room without previous written authorisation.
PROCEDURE:
The installation must be done by qualified people based on the information given in this manual and in accordance with national regulations and standards. Upstream of the electrical power system, you must install a CLASS "A" GROUND FAULT CIRCUIT INTERRUPTER. Check that the flooring is flat and even.
SAFETYWARNINGS
The equipment must not be used by children under the age of 8 and by people with reduced physical, sensorial or mental capabilities or those lacking the necessary experience or knowledge, other than under supervision, or if they have been given instructions for the safe use of the equipment and therefore understand the risks involved in its use. Children must not play with the appliance. Cleaning and maintenance intended to be carried out by the user must not be carried out by children without supervision. Care should be taken when using the appliance due to the hot temperature.
The sauna must not be used by children under the age of three, anyone with heart disorders, internal inflammation, epilepsy or people with a pacemaker.
Sauna heaters must not be subjected to water spray and shower heads must not be installed above the sauna heaters.
CAUTION:AVOIDAFIRE,DONOTPLACECOMBUSTIBLEMATERIALONTHESAUNAHEATER.
CAUTION:USEONLYACONTACTORAPPROVEDFOR25O,00OENDURANCE CYCLES.
The door of the heated room should not include any locking or latching system.
Its malfunction could cause entrapment inside the room. It is always advisable to consult your own doctor before using the sauna.
"Hyperthermia" occurs when the internal temperature of the body reaches a level several degrees above the normal body temperature of 37°C. The symptoms of hyperthermia include an increase in the internal temperature of the body, dizziness, lethargy, drowsiness, and fainting. The effects of hyperthermia include:
a) Failure to perceive heat;
b) Failure to recognize the need to exit the room;
c) Unawareness of impending hazard;
d) Fetal damage in pregnant women;
e) Physical inability to exit the room;
f) Unconsciousness.
WARNING- The use of alcohol, drugs, or medication may greatly increase the risk of atal hyperthermia.
Children over the age of three may use the sauna only under the supervision of an adultandafterseekingmedicaladvice.
Any use of the home spa for purposes other than those expressly prescribed is strictly prohibited.
Do not remove the adhesive labels affixed to the internal surfaces of the units, for any reason.if they deteriorate,request replacements.
Users must be fully informed about how to use it.
Read this manual carefully before using the sauna.
Pay careful attention to the hazard warnings and safety standards issued by the authorities ineach country.
A
When this heater is not installed for use with an attendant or is contolled by remote with APP, a timed-cutoff switch must be connected in the input circuit to disconnect allungrounded conductors of the heater circuit from the supply source at the end of 1 hour of operation. The timed-cutoff switch must be located outside the heater room,or mounted on a wall or door inside the heater room. The time feature of the switch must not lend itself to being overridden.
All measurements are in mm.
UNPACKING
IMPORTANT. After removing the packaging, check that all the items and materials are complete and undamaged. If damage has been caused during transport, the carrier must be notified within the legal periodso as not to forfeit theinsurance cover.
Sauna Room Hygiene
Each time the sauna is used, we recommend cleaning both the slatted floor boards and the benches that have been used so as to guarantee,among otherthings,correcthygieneoftheproduct.
The wooden surfaces of the sauna must never be chemically treated,not even with common varnish or paint, since it would negatively affect the natural characteristics of the wood and on the one hand would make the sauna totally ineffective and on the other would give rise to risk of severe burns to the body.
Clean the sauna cabin with a wet cotton cloth and dry it with a clean,dry cloth regular cleaning ensures the long life of the sauna NO complaints are accepted in respect of certain natural imperfection in the wood such as slight colour tone variations or small cracks or splits.
Spacerequired around the sauna foreasy assembly.Ifa smallerarea is available, pleasecontactthemanufacturer.
ELECTRICALSAFETY:
ORANS saunas are manufactured and tested in compliance with European regulations to ensure the utmost safety for users.
ELECTRICALCONNECTION:
The sauna must be connected to the power grid using a CLASS "A" GROUND FAULT CIRCUIT INTERRUPTER adequate for the power consumption of the product. The AC electrical connection must be:
- fixed;
-adequate for the current absorbed.
If the sauna is installed in a bathroom, the following requirements must be met: - the CLASS "A"GROUND FAULT CIRCUIT INTERRUPTER must be placed outsidethewetzone.
- the AC electric connection must be protected from water.
In any case, always comply with the requirements of the national regulations withregardstothepositionoftheelectricalelements. N.B.
The product must be installed in an area with finished floors and walls.
Parts
The partsbelow are numbered with the letter
Spare parts
Product installation tools
Tools required for installation(not supplied)
UKU WiFi/LOCAL
CONTROL SYSTEM OFELECTRICSAUNAHEATER
UKU WiFi/LOCAL HEATERCONTROLCONSOLE InstallationAndUserInstructions
ATTENTIoN!The following instructions forelectrical works must becarried out by a licenced electrician.
ATTENTION!Mainmodulecanbeusedwithheatersupto11kW.
ATTENTION! This appliance is not intended for use by people (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge.
ATTENTION! Children should be supervised to ensure that they do not play with the appliance.
ATTENTION! The installation instructions for appliances for public saunas that do not have a timer shall state that a pilot lamp showing that the heater is switched on is to be installed in the attendant's room.
For installation in public saunas, a separate timer compliant with
UL 60730-1and UL60730-2-7 along with CSA E60730-1and
CSAE603730-2-7standardsmustbeused.
The devices set includes:
UKU control panel;
Main module (6^{7}/8x9^{27}/32x2^{15}/16~i\mathsf{n}/~175x250x75\mathsf{mm}) Temperature sensor;
Door sensor;
Temperature and door sensor cables (197+197in/5+5 m; 2x28 AWG);
UKU control panel cable (118 \mathsf{i n}/3\mathsf{m} 4x22 AWG).
ATTENTION! Keep this operating manual near the device so that at any time you can get safety and important information for using the device.
BEFOREINSTALLATION
Before installation read the operation manual thoroughly. Do not install or perform maintenance on the device if you do not understand all of the instructions. Contact vendor or local distributor with any questions or concerns. This way you can use all the benefits of the device and prevent damage.
The device must be installed and serviced in strict accordance with this manual, and all local/state/federal codes. You must obtain allrequired building and similar permits before commencing installation of the sauna equipment.
Allpower must be turned off from the circuit when installing or maintaining the device
For unique problems that are not covered in the installation manual, contact your vendor or local distributor to ensure safety.
Itisnotpermittedtoalterorrebuildthecontroldevice
The manufacturer has the right to make improvements to the device. The latest version of the operation manual can be found on the webpage (huumsauna.com)
Make sure supply conductors are properly sized per tables, new wiring is recommended.Installonadedicatedcircuit.
It is recommended to connect the unit to the mains without a GFCl breaker.
UKU control system allows the sauna temperature to be set between 104-230°F/40 and 110°C
Symbols used in the installation manual:
WARNING! Not following these instructions may lead to property damage and serious or fatal injuries.
ATTENTION! Also, follow the special safety requirements given in the individual chapters. Dispose the packaging material according to the applicable disposal rules and regulations.
In the guide, the following details of the sauna are marked with numbers:
UKU control panel
Main module
Door sensor
Temperature sensor
Heater (not included)
Vaporizer (not included)
Light (not included)
INSTALLINGUKUELECTRICAL CONTROLDEVICE
Before installation disconnect the electric heater from the power supply.
The control panel 1 must be installed outside of the sauna room, at theuser'seyelevel nexttothedoor.
If your main module \otimes supports the use of the WiFi connection it must be installed where sufficient reception is available.
The main module must be installed in a dry location. The device has a protection degree of IP67. Power cables must be secured using the provided cable glands.
To prevent damage to the main module, a room temperature of 122°F 50^{\circC)} and relativehumidityof 95% mustnotbeexceeded.
Before powering the control panel, it must be made sure that the main module is sealed so that no humidity can access the inside.
CAUTioN! The main module must be permanently connected to the circuit. A circuit breaker must beinstalled to disconnect all poles from the mains. The power cables of the main module must meet the requirements of UL 62 in the US and CSA 49 in Canada, with a minimum temperature rating of 140°F (60°\mathsf{C}) The gauge of the cables depends on the power of the heater; refer to the heater manual for guidance. Always let the correct cable size be approved and installed by a qualified electrician.
ATTENTION! Crimping the power cable ends is mandatory.
The compression of the metal sleeve ensures that the wire threads are held in place, minimizing the risk of loose connections that can cause electrical faults or pose safety hazards.
ATTENTION!A method to disconnect all poles from the mains(a circuit breaker) mustbeinstalledonthepowercircuit.
ATTENTION! Measure the lengths of the cables and determine the locations of the cables and the parts of the device(Figure 1).
Control panel
WARNING!To avoidover-threadingthescrewthreads,tightenthe screwsonlybyhand.Donotuseelectricscrewdrivers.
The cable of the controlpanel should notexceed 20 m/ 65 ft.
The cable of the control panel should not be routed parallel to the high current cables.
Door sensor
The door sensor kit includes a sensor, magnet, and magnet fixing tape.
The length of the cable between the sensor and the main module should not exceed 32 ft (10m).
Install the sensor on the handle side of the door frame, at a maximum height of 16 in (40 cm) from the floor. When installed higher, the temperature may affect the performance of the magnet and the durability of the magnet tape.
It is important to ensure that the door passes directly by the sensor in the door.
Use a 13/64 in (5mm) diameter drill when installing a door sensor recessed in the door frame.
Drill a hole and install the sensor.
ConnectthecabletoterminalsO1ando2inthemainmodule.
Connect the other end of the cable to the cables attached to the door sensor.
Install the door sensor magnet to the door leaf using the provided double-sided tape.
When closing the door, the sensor and the magnet should remain slightly displaced, and the distance between them should not exceed 13/32 in (10 mm).
Steamer
The maximum power of the steamer is:
·1250W,120V/60Hz;
·2500W,240V/60Hz. Connect SL (phase) sN (neutral) to the outputs of the steamer.
To connect, see the figure 1.
After connecting the streamer, turn on the steamer function in the control panel settings. See the "Humidity settings" section of the operation manual page 18.
ATTENTIoN! When connecting the control system with an electrical heater with a steamerfunctionensurethat the watertank is alwaysfilled with water.When the water tank is empty, the steamer function is disabled and there is a risk that the heating element may burn out.
ATTENTIoN! The steamer cannot be used with target temperature above 194°F (+90°\mathsf{C})
Ventilation device / lamp ⑧
It is possible to connect a lamp or a ventilation device to the outputs LL (phase) LN (neutral) of the main module. To connect, see the figure 1.
The maximum power of an incandescent lamp/ventilation device is 120V 100W and with LED lights 120V 50W.
After connecting the device, turn on the "Vent/Lamp" function in the control panel settings, see the corresponding section on page 16 in the operation manual.
If the lamp or ventilation device is connected and the corresponding function is active in the menu, you can turn the connected device on and off using the control panel.
Connecting the UKU WiFi controller to the network
The WiFi modem complies with 802.11 b/g/n standard.
The main module supports only 2.4 GHz WiFi networks.
UKU should be connected to the unique 2.4GHz WiFinetwork.If the name of the network matches with that of 5GHz or 6GHz network, it should be changed.
ATTENTiON! The main module doesn't support WiFi network names and passwordslongerthan20characters.
To enter the control panel menu settings, hold down the panel button for 9 seconds.
Go to "WiFi settings" and select "ssiD" from there. You can confirm the options by clicking on the button.
In the opened menu, find the wiFi network to which you want to connectyoursauna controlsystem.
If you have selected a WiFinetwork,please enterits password.
After entering the password, click connect and follow the instructions on the screen.
In the operation manual, information on connecting the sauna to the mobile application has been provided in the chapter "HuuM mobile application" on page 13.
If you have problems connecting the control system to the WiFi network, you can find video instructions and the fastest help at: huumsauna.com.
HUUM mobile application
The UKU Wi-Fi can be controlled through the control panel or via a smart-phone using the dedicated HUUM mobile application. This feature enables users to operate the sauna remotely, even when away from home.
Download the HuuM application from the application page of your mobile phone's operating system:
Create an user account in the application.
Connect the control system ID (2XXXxx) with your account. The ID of the control system is also the ID of your sauna, you can find it on the sticker located in the upper right corner of the main module cover. The code is also provided on the cover.
Check whether the functions of the mobile application (e.g. selection of sauna temperature and heating time, heating on and off) work and reach the sauna. The function should start within 60 seconds of selecting the command in the menu. In case the functions of the mobile application are not activated, contact us at: support@huumsauna.com.
Thenumberofuseraccounts linked toonesaunaisnot limited.
How to add WiFi capability to your UKU Local control system?
If you have purchased a UKU Local control system, but want to add WiFi capability to it, you can do so in the HUUM mobile application. The upgrade is activated remotely for an additionalfee and does notrequire anon-sitetechnician.
To do this, download the HUUM mobile application, create an user account and link it to your sauna ID (see the previous section “HuuM mobile application").
Youwill getfurtherinstructionsfromthe mobile application.
TESTING
ATTENTION!Onlyacertifiedelectriciancancarryoutthetests!
WARNING!Testsmustbecarriedoutwhilethepowerison. Riskofelectricshock!
WARNING! Before starting the test, check that the heater is installed according tothemanufacturer'sinstructions.
1.Check the power terminals of the circuit breaker and the main module.
Bad connections may cause a fire. Switch the power on from the switchboard by using the circuit breaker. The screen will flash for a moment. The device is ready for use.
2. Check the temperature sensor
If the error message Temperature sensor error!" is displayed on the screen of the control panel, check the temperature sensor cable connections on both the sensor side and the main module side.If the error message does not dissapear, the temperature sensor must be tested. For testing, connect it to the main module with a shorter wire, ruling out a faulty wire.If there is the same error message afterwards, then proceed to the next testing method. The final, most thorough testing method is measuring the resistance of the temperature sensor. It should be around 1,1 kOhm at 68°F (20°C) .If the resistance is correct, the fault is in the cable or connections. If there is no resistance, the sensor is damaged and must be replaced. For a replacement sensor, please contact your vendor or local distributor who sold you the HUUM control system.
In other cases,to test,turn off the circuit breaker of the sauna fora minute and then turn it back on. The control panel should be switched off and display the current temperature when switched on.
Adjust the target temperature of the sauna to 122°F ⟨50°C⟩ . Turn on the sauna. If the control panel indicates that the sauna has reached the desired temperature, make sure after 30 minutes that the desired temperature remains noticeably the same. Turn off the heating.
3. Checkthe door sensor
Close the steam room door. Turn on the controller and set the temperature. Turn on the heating. The heater starts heating and the heating elements start glowing red. The relays should activate. Open the steam room door. The relays should disconnect within 5-10 seconds and the message “Door open" appears on the screen. Close the door. The relays activate again, the message disappears and heating continues.
CONTROLPANELUSERMANUAL
Before use, make sure that you have made the necessary connections according to your control system model. (see Connecting UKu WiFi control system to the network" on page 12.)
A short single press of the button turns the control panel on and starts or stops the heating. The display remains active throughout the heating period.
You can set the maximum possible heating time of the heater in the menu of the control panel on the wall. In case of private saunas the choice of heating time is 3 or 6 hours, in case of semi-public saunas 12 hours and in case of public saunas 18 hours. By using the mobile application you can choose the heating time yourself, but its length cannot exceed the settings of the control panel.
The current sauna temperature is displayed in the middle of the screen.
The target sauna temperature is indicated by a number in the upper right corner of the screen. Turn the button to select the target temperature.
Press the button to start heating. During heating the heating symbol is displayed above the temperature on the screen ( SS)
To enter the control panel settings menu, hold down the button for 9 seconds.
Select"Back" for each function to exit the menu.
Timing of heating
UKU control system allows you to schedule the start of heating.
To activate thetimerfunction,press and hold thebuttonfor6seconds.
When the desired time is selected, a single short press on the button switches the timer on. The function of the timer will not activate unless you press the button!
The timeline appears on the screen, showing how much time is left until the heater is turned on.
Control panel settings menu
The following parameters can be set in the menu:
WiFi settings - changing WiFisettings, selecting a suitable network and connecting to it.
Press andhold thebuttonfor9 secondsto enter thecontrol panel settings menu.
Go to the "wiFi settings" option. The necessary steps for selecting the WiFi network and establishing the connection have been described in the section"Connecting UkU WiFi control system to the network" on page 12.
Lamp settings settings for controlling devices connected to the control system (e.g. ventilation, sauna lamp)
1. Vent/Lamp
To control devices connected to the control system from the control panel, this function should be turned on (On).
Pressthebuttonfor9secondstoenterthemenu.
Find the "Lamp: On/off" function in the menu and make the choice that suits you.
If the functionis active,you can turn therelevant device on or off with two quick button presses using the control panel.
2. Door switch
If the function is activated, the device connected to the control system (e.g. ventilation, sauna lamp) turns on automatically for a user-defined time period of 10, 15 or 20 minutes when the sauna door is opened.
Press thebuttonfor9 secondsto enter the menu.
Find the"Door switch"function in the menu and choosea suitable period of10,15or20 minutes.
ATTENTSION! The devices are connected to the outputs LL (phase) LN (neutral) of the main module of UKU control system. The maximum power of the device is 100 w, voltage 120 v/50 Hz.
Heating settings - heating settings of the heater.
1. Temperature unit
The function allows you to choose the measurement unit of the sauna temperature: ^\circ\mathsf{C} (Celsius) or °F (Fahrenheit).
Press thebuttonfor 9 secondsto enterthe menu.
Find the"Temperature unit"function in the menu and select the appropriate unit of measurement.
2. Heating time
Allows you to set the heating time, after which the control system automatically turns off the heater.
Press thebuttonfor 9 seconds to enter the menu.
Find the "Heating time" function in the menu and set the heating time according to your sauna type:
\mid\rightarrow\mid Privatesaunas3hor6h \rightarrow Semi-public saunas 12h \mid\rightarrow\mid Publicsaunas18h
When using the local control panel, the heater follows the heating time specified in the settings, but the user can also stop the heating earlier.
When changing the heating time to more than 6 hours (max heating time for private saunas), the user should confirm that it is a semi-public sauna (max heating time 12h) or a public sauna (max heating time 18h).
3. Max temp/Min temp
The function allows you to set the minimum and maximum temperature range of the sauna.
By default, these values are min 104°F (40°\mathsf{C}) and max 230°F (110°\mathsf{C})
Press and hold the button for 9 seconds to enter the settings menu.
Find the "Min temp" function in the menu and select the appropriate temperature.
Repeat the same to set "Maxtemp".
ATTENTION!Thelimitationssetinthecontrol panel menu cannotbe overriddeninthemobile application.
Humidity settings - sauna steamer settings.
1.Steamer
To control the steamer connected to the control system from the control panel, the function should be activated (on).
In the default setting, the function is enabled. If you wish to disable it, please followthe described steps.
Press thebutton for 9 seconds to enter the menu.
Find the"Steamer:On/off"function in the menu and make the appropriateselection.
To adjust the humidity level in the sauna, push the button down and turn it to the right (higher humidity) or to the left (less humidity). You can make this selection in the main view of the control panel.
The intensity of the steamer is displayed in the lower left corner of the screen (e.g. within 0-99).
The steamer works only when the sauna is in heating mode.
The control system regulates the steam generator using a formula, so the actual humidity in the sauna may vary depending on the characteristics of the sauna.
ATTENTION! The steamer does not start immediately after activating the heater, but shortly before the target temperature is reached. This ensures a faster heating time.For more information, see "Hum. start temp"
ATTENTION! The steamer function will be automatically deactivated if the set temperatureishigherthan 194°F (90°\mathsf{C})
Hum. start temp
Defines how many degrees before reaching the target temperature the evaporator starts working.
Default: 50°F (10°C) . Possible range: 32-68°F (0-20°C) . Selecting O means the steam generator starts working when the target temperature is reached in the sauna.
Pressthebuttonfor9secondstoenterthemenu.
Find the "Steamer settings".
Find the "Hum. start temp" function in the menu and select the appropriate degree. To make your selection, turn the knob, then confirm the selection by pressing the button.
Hum. display style
Press thebuttonfor9seconds toenterthemenu.
Find the "Steamer settings".
Find the “Hum. display style" function in the menu and select the desired style by clicking. You can choose between two options: "% of maximum allowed" and "Relative humidity %": To make your selection, press the button.
96 of maximum allowed
You can set the maximum allowed percentage of relative humidity at the given target temperature. The maximum relative humidity in the sauna is specified by the standard.
Relative humidity %
You can select the relative humidity for your sauna. The maximum relative humidity in the sauna is specified by the standard and varies according to the target temperature. The higher the temperature, the lower the permissible relative humidity in the sauna. Refer to the accompanying chart.
2. Steamer safety
This function notifies you when the steamer has run out of water.
In the default setting, the function is enabled. If you wish to disable it, please follow the described steps.
Press the buttonfor9 seconds to enterthe menu.
Find the“Steamersafety:On/off"functionin the menu and make the appropriate selection.
When the main module detects that the water has run out, the steamerturns off.
It is not necessary to use thesetting if the steamer already has a built-in water level sensor.
Safety settings - setting up the safe use of the sauna.
1. Remote start safety
To confirm the safety of your sauna for remote heating activation, follow the steps below:
Close the door of your sauna (if you have the control panel installed inside the sauna, still follow the steps mentioned below. After confirming, you have 15 seconds to leave the sauna and close the door).
Press and hold the control panel button for 3 seconds until the safety confirmation prompt appears.
By answering yes, remote (from the phone app) launch is enabled. It is indicated by three gray dots ( ... ) on the control panel screen
If you do not answer or the answer is no, the system will not allow you to start heating from the mobile phone.
Once you've confirmed the safety of the sauna, it will be considered safe until someone opens the door again.If the door is opened,before you start the sauna from your app, the remote launch will be deactivated and the above mentioned steps have to berepeated.
ATTENTIoN!In the settingsmenu it is possible toturn off theremote launch confirmation on the control panel. In this case, you can remote launch (from the phone app)your sauna,without confirming the safety of the sauna on the control panel. If you would like to do this, follow the steps mentioned below. By turning off the test question, the sauna may be started remotely without confirmation that conditions in the sauna are safe. This may result in property damage, and serious or fatal injuries.
Pressthebuttonfor9 seconds toenter themenu.
Go to "Safety Settings".
Find thefunction"Remote startsafety:Enabled/Disabled".
Select"Disabled".
2. Overheating pause On/Off
The sauna control system has mandatory pausing mechanism during heating. This pause algorithm addresses situations where the heater's power is insufficient for the specific sauna room, or the ventilation is done incorrectly, causing the heater to operate at full capacity continuously. By implementing these pauses, the system reduces the risk of overheating surfaces near the heater.
The pause logic:
1. 90 minutes of heating.
2. 10 minutes of pause.
3. An additional 10 minutes of pause or pause until the temperature drops by
10 degrees from the start of the pause.
4. 45 minutes of heating.
5. 10 minutes of pause.
6. An additional 5 minutes of pause or pause until the temperature drops by
10 degrees from the start of the pause.
7. Repeat steps 4-6.
8. When the desired temperature is reached, the logic stops.
If youwould liketodisablethepausesfunction:
Pressthebuttonfor9secondstoenterthemenu. Go to "Safety Settings" Go to“Pauses”and select"OFF"
Failure det
Turns on/off the logic that shuts off the heater when abnormal heating behavior is detected. The logic - if the temperature does not rise by 86°F ⟨30°C⟩ within 60 minutes of heating, the heater will shut off. This only works if the initial temperature of the sauna is below 104°F (40°C) when heating starts.
Child lock
The child lock function adds security and prevents unauthorized persons from operating the heater without supervision.
To enter the menu, hold down the button on the control panel for 9 seconds.
Go to "Safety Settings".
Find the"Child lock: on/off"function in the menu and make the appropriate selection.
If the function is activated, the child lock is applied automatically when the screen of the control panel turns off.
To remove the child lock and activate the screen, while holding the button, turn it a quarter turn to the right, then backto the beginning, then a quarter turn to the left and back to the beginning.
Settings password
If necessary, it is possible to protect the settings menu with a password.
You can turn on the function and set the password in the settings menu.
To enter the menu, hold down the button on the control panel for 9 seconds.
Go to "Safety Settings"
Find the"Settings password: on /off" function in the menu and make a suitable choice.
Set a password.
If the function is on, the user will be asked for a password every time when entering the menu.By default, thefeature is turned off.
NB!Once you have set apassword,store it securely.If you forget orlose your password, contact the user support at: support@huumsauna.com
Using the mobile application
You can download HUUM mobile application to your phone:
You can find information about creating a user account and connecting the sauna to the application in the section "HuuM mobile application" on page 13.
In HUUM mobile application you can:
\mid\rightarrow\mid Set the desired sauna temperature and heating time (the last time setting remains in the memory)
\rightarrow Turn the sauna on and off.
\rightarrow Control sauna steamer and lighting functions.
\rightarrow Get notifications when the target temperature is reached and the sauna is ready.
\rightarrow Set the sauna heating times up to two months in advance.
Instructions for navigation can be found inside the application. The buttons (!) provide detailed additional information.
GENERALSAFETYINFORMATION FORTHEUSER
All included sensors must be installed with the control system.
When the overheating protection is applied 266°\mathsf{F} ⟨130°C⟩ , the sauna must be inspected and the safety of the sauna should be ensured. When the overheating protection is activated, the error message "Temperature sensor error" appears on the screen. If the overheating protection is triggered, it indicates that the temperature sensor is permanently damaged. For a replacement temperature sensor,pleasecontactthevendororlocaldistributor.
It is not allowed to modify or rebuild the device.
If you encounter any issues not addressed in this manual, please contact the vendor orlocal distributorfrom whom you obtained the deviceforassistance.
The manufacturer has the right to make software updates to the device. You can find the latest version of the operation manual on our website: huumsauna.com.