LD-TS04
BusDevice Addresser
Features:
Setaddressanddevicetypeforthee-codedbusdevice.
■ Setthenumberofelectrical firedetectorchannels.
■ Setthefeedbackaddressforthefirehydrant.
■ Setalarmarea for thesoundandlight.
■ Setsingleordoubledoor(s)forthefiredoor.
■ EquippedwithDC3.5plugcordtoreadandwritetheaddressofelectrical firedetectorand fire power supplymonitoringsignal sensoroffire fighting equipment online;setthe number of electrical fire detector channels.
■ Lowpower consumptionand automatic shutdown.
1 Batteryundervoltage indicator.
Smallsize,easytocarryandoperate.
LD128EN-101
Adapter Base
Features:
ThebaseworkswiththeLD128EN-101busdeviceaddressertoimplement addressingwithG seriesbusproducts.
Auxiliary Products
LD5801(A)-5A/LD5801(A)-10A
Wall-Mounted Linkage Power Supply
Features:
Wall-mounted.
Switch between main powerand battery.
Withthe functionofmainandstandbypowersignal output.
SupportDC 24Voperatingvoltage for linkagemodules.
IG-X1051F/IG-X1101F/IG-X1201F/IG-X1301F
SmartPower Box
Features:
Wall-mounted.
Switch betweenmain powerand battery.
SupportDC24Voperatingvoltage forlinkagemodules.
IG-X1051H
SmartPower Box
Features:
1 Wall-mounted.
1 Switchbetweenmainpowerandbattery. Mainpower long-termovercurrent protection,self-recovery. Zeroleakagecurrentafterbatteryoverdischargeprotection.
1 Precisechargeanddischargemanagement. Batteryreverse protection.
1 Backup grounding protection.
□ Output shortcircuit protection
WK-BDII 10 Fire Power Supply
Features:
Wall-mounted. Takingtwobusaddresses,itiswiththefunctionofmainpowerand battery
signaloutput;code the module in the power supply whenusing the main power
andbatterysignal and connect ittotwo busfor power statusupload. Switch betweenmain powerand battery.
Auxiliary Products
Batteries
Main specifications::
WK-BDII5
Fire Power Supply
Features:
Wall-mounted. Takingtwobusaddresses,itiswiththefunctionofmainpowerand battery
signaloutput; code the module inthe power supply whenusing the main power
andbatterysignalandconnectittotwobusforpowerstatusupload. Switch betweenmain powerand battery.
| NO. | Specification | Rated voltage(V) | Rated capacity(Ah) | Constant current discharge time(0.05C)(hr) | Weight(Kg) | Service life(year) |
| 1 | 6V4Ah | 6 | 4 | 20 | 0.64±3% | 2 |
| 2 | 12V4Ah | 12 | 4 | 20 | 1.23±3% | 2 |
| 3 | 12V 7Ah | 12 | 7 | 20 | 1.8±3% | 2 |
| 4 | 12V12Ah | 12 | 12 | 20 | 3.0±3% | 2 |
| 5 | 12V14Ah | 12 | 14 | 20 | 3.1±3% | 2 |
| 6 | 12V38Ah | 12 | 38 | 20 | 9.4±3% | 2 |
LD5900EL(B)
StandardCabinet
Features:
Asaverticalcontrolcabinet,itisapplicable tovariousdevicesasrequired byprojects.
Rearopeningand bottomwiring-out.
The front panel ofstandardcabinetsis 28U.
Thedistanceagainst wall should beatleast1 meter.
Weight:56.3Kg±0.5Kg.
LD5900EL(C)/LD5900EL(D)
Console Cabinet
Features:
Asaconsolecabinet,itisapplicabletovariousdevicesasrequiredby projects.
Both frontand rearopening.Bottomwiring-out.
The front inclined panel is 9U.
Thedistancebetweenitsrearandwallshouldbeatleast1meter.
Thetableisdetachable,easytocarryand handle.
Weight: LD5900EL(C) 35.45Kg±0.5Kg;LD5900EL(D) 55.65Kg±0.5Kg.
Auxiliary Products
LD5900EL(F)/LD5900EL(G)
LinkageCabinet
Features:
Asalarge-sizecontrol cabinet,itmeetstherequirementsofindustrial
projects. ItisinstalledwithourstandardcabinetLD59ooEL(B) inside.Itisapplicable
tovariousdevicesasrequiredbyprojects. Glass door in the front and double door in the rear. Installed withilluminatingapparatusin the inside roof plate.
1 Installedwith groundcopperbaratthebottom.
□ Thescreen-printed logo and textat the door header are provided by
customer,and the height of thedoor headeris60mm.
1 2000mm,2100mmor 2200mm is theoptionforcabinetheight.
一 Rearopeningand bottomwiring-out. The distance against wall should be at least 1m.
WiringTerminalBox
Features:
Designedfordividingandwiringoffirealarmsystem. Surfacespraytreatment,withalongservicelifeandavarietyof specifications to choose.
ModuleBox
Features:
Designed formoduleplacementinthefirealarmsystemand meetsthe requirements formodule placement in GB50116-2013. Surfacespraytreatment,withalongservice life. Wall-mounted,embeddedandcontrolcabinetareavailable,withariety ofspecificationstochoose.
Features:
Enclosure protection class:IP44. Supportforour point photoelectric smokedetector,heatdetectorand combustible gasdetector. PG16 plasticGolanheador@20threading tubeisrequired. ■ Ceiling installation. ■ Weight: 0.10Kg±0.005Kg.
Auxiliary Products
Features :
Enclosure protection class:IP66.
Support forourpoint photoelectric smokedetectorand heatdetector.
CableGolan headG1/2isrequired.
Ceiling installation.
Weight; 0.62Kg±0.005Kg.
Features:
Enclosure protection class:IP65. Supportforourmanual firealarmbuttonsofEN seriesand modulesofED series. PG16 plasticGolan headisneeded. Wall-mounted. Weight:0.19Kg±0.005Kg.
Features:
Enclosure protectionclass: IP65. Supportforourmanual firealarmbuttonsofGseriesandmodulesofG series. PG16 plastic Golan head isneeded. Wall-mounted. Weight:0.19Kg±0.005Kg.
Features:
Enclosure protectionclass: IP66. SupportLW5606andLD13o0 gasreleasealarmforindoorandoutdooruse. Theinletandoutletline holesarelocated below,and the PG7waterproof jointsshall be installed on site. Wall-mounted. Weight:2.08Kg±0.01Kg.
Auxiliary Products
Features:
Protectionclass:IP66. WiththeLD1300andLD13o0(F)gasreleasealarm forindoorandoutdoor
use. Cableinletandoutletholesarelocatedbelow.PG7waterproofconnectors
need to be installed onsite. Waterproofsound permeablemembrane. Wall-mounted. Weight:2.08Kg±0.01Kg.
Features:
Enclosure protection class:IP65.
Supportforouraudible/visiblealarmsofENorGseries.
PG16 plastic Golan head isneeded.
Wall-mounted.
Weight:0.19Kg±0.005Kg.
FHX-M4
Protective Case
Features:
Enclosure protection class:IP66. Support LD1200A/LD1200EN/LD1200G onsite emergency start/stop button,
LD2003Gmanual firealarmbutton,LD2oo4G fire hydrantbutton,LD6930
communication networkingcard or YJGF3040A multi-wire fire telephone
extension foranoutdoor or indoor use. Wall-mounted. 24/7 hours protection.
Features:
Enclosure protection class: IP66. ProvideprotectionforourLD988EMfirealarmcontrolunit,and1o8series /LD5507EN standardized small wall-mounted control unit. PG13.5 plasticGolan head isneeded. Wall-mounted. Weight:15Kg±0.1Kg.
Auxiliary Products
Features:
Enclosure protectionclass:IP66. Provide protection forourLD128EN(M) firealarmcontrol panel,JW
XOM-LDDTS1oKdistributed fiberoptic linear thermal firedetectorand118
seriesstandardized small wall-mounted control unit. PG13.5 plastic Golan head isneeded. Wall-mounted. Weight:16.5Kg±0.1Kg.
Features:
Enclosure protection class: IP66. Provide protectionforourEDseriesmodule,andupto6EDseriesmodule can be installed. PG13.5 plastic Golan head isneeded. Wall-mounted. Weight:7.2Kg±0.1Kg.
Features :
Protection class:IP66. Itisused withwall-mounted powersupplyIG-X1051F,IG-X1101F,IG
X1201FandIG-X1301FandDH9361F/BGfiretelephonehost. Cableinletand outletholesare locatedatthe lowerpart.APG13.5
waterproof connectorisrequired for onsiteuse. Wall-mounted. Weight:7.2Kg±0.1Kg.