火灾报警及消防联动系统产品样本 Product Catalogue for Fire Alarm and Fire Linkage System LEADERGROUP 2024/10 V1.0
Introduction
LEADERGroup,foundedin1990isacomprehensiveorientedenterprisededicatedtohumansecurityandenvironment protection.Itconsistsofseveralspecificsubcompaniespresentlywithawidescopefocusingonfirealarmcontrolsystem,gas extinguishingstemelectricfmoitorsstemaswellassinandonstructionofityfeprotectionnetworkandprect addition,LEADRoupasiedmaableevementsatedtooentsfetyoitoringatertoicitystinad environmentsafety evaluation.
LEADERGroupposssssofastrongdistributionetworkhichcoversover3Oprovincesandcitiesinlandaswellasover20 countriesandregionsallovertheworld suchasSoutheastAsiaandMiddle East.
Advancedtechnicalknow-howandoutstandingstrengthguaranteeLEADERGrouptoprovidecomprehensiveandhighquality servicecontinuously
Uontents
IDetectors 01
IIManualFireAlarmButtonandFireHydrantButton 11
IIIModulesand Isolators 17
IVAudible/VisibleAlarms 27
V Fire Display Panel 31
VIFireAlarmControlUnit,LinkageControl Paneland 33
Linkage Power Supply
VII Fire Emergency Broadcast System 45
VIII Fire TelephoneSystem 51
IX Graphic Display Device 67
X Gas Fire Extinguishing Control System 71
XI Combustible Gas Alarm System 79
XII Intelligent Fire Network System 83
XIII Auxiliary Products 95
Automatic Fire Alarm System
Detectors
JTY-GM-LD3000G
PointPhotoelectric Smoke Detector(Coded)
Features :
Two-bus,non-polarity.
2nd generation of distributed smart product with MCU built-in.
E-coded,takingoneaddresspointata rangeof1\~255.
Blacksmoke is visible duringalarm.
Asananalogaddressablesmokedetector,itiscapableoftransmittingon
sitesmokeconcentrationdatato CIE.
JTY-GM-LD3000G
PointPhotoelectric SmokeDetector (Intrinsicallysafe explosion proof,coded)
Features :
Two-bus,non-polarity. 2ndgenerationofdistributedsmart productwith MCUbuilt-in. E-coded, takingone address pointata range of1\~255. Blacksmoke isvisibleduringalarm. ■ Asananalogaddressablesmokedetector,itiscapableoftransmitting on sitesmoke concentration datato CIE. ■ Explosion-proof.SupportedbyaLD48ooED-A relaymodule.
JTY-GM-LD3002G
Point Photoelectric Smoke Detector (Non-coded)
Features :
Two-bus,non-polarity. 2nd generationof distributed smart product with MCUbuilt-in. ■ E-coded,taking oneaddresspointatarangeof1\~255. ■ Blacksmoke isvisibleduringalarm. ■ Asananalogaddressablesmokedetector,itiscapableof transmittingonsite smoke concentration data to the control unit. ■ Dualphotoelectric smokedetection,resistance toavarietyof environmental interference,mainlyusedintypicalcultural heritage buildingprojects.
JTY-GF-LD3000G(F)
PointPhotoelectric Smoke Detector (Non-coded)
Features :
Two-bus,non-polarity.
Non-coded.
2nd generation of distributed smart product with embedded MCU.
Alarmwithblacksmoke.
Transmitalarmand faultinformationtoourcontrolunitsviaLD4900G
relaymodule.
Detectors
JTW-ZDM-LD3300G
PointHeat Detector(A2S)(Coded)
Features :
Two-bus,non-polarity.
2nd generationof distributed smart productwith embedded MCU.
E-coded,takingoneaddress pointata range of1\~255.
Featuredwithconstanttemperature.
Asananalogheatdetector,it transmitson-site data tocontrol unit.
JTW-ZDM-LD3300G
Point Heat Detector (A2S) (Ex) (Intrinsicallysafe explosion proof,coded)
Features :
Two-bus, non-polarity.
E-coded,takingone address pointata range of1\~255.
Built-inMCU,highreliabilityandlowfalse positives.
Highmoisture resistance and anti-interference.
Explosion-proof. Supported bya LD480oG-A relay module.
JTW-ZDF-LD3300G(F)
Point Heat Detector (A2S) (Non-coded)
Features :
Two-bus,non-polarity.
Non-coding,withtakingaddress point.
Built-in MCU,high reliabilityandlowfalsealarmrate.
Staticultra-lowpowerconsumption.
High moisture resistance and anti-interference.
Featured with bothconstant temperature and non-differential temperature.
JTF-GZM/LD3200E
PointCombined Smokeand HeatDetector(A2S)(Coded)
Features :
Two-bus, non-polarity. E-coded, takingone address point. Built-inMCU,highreliabilityandlowfalsealarmrate. High moisture resistance and anti-interference.
1 Withdual-sensor technique of photoelectric and temperature,no pollution.
一 Withour proprietary digital bustechnology fordata transmissionand
onsitedata acquisition. Asananalogmulti-sensordetector,itisfeaturedwithconstanttemperature. Alarmwithblacksmoke.
Detectors
JTF-GDF-LD3200E
PointCombinedSmokeandHeatDetector(Ex) (Intrinsicallysafeexplosionproof,coded)
Features:
Two-bus,on-polrity. E-coded,takingoneaddresspoint. Built-inMCU,highreliabilityandlowfalsealarmrate. Highmoistureresistanceand anti-interference. Withdual-sensortechniqueof photoelectricand temperature,no pollution. Withourproprietarydigitalbustechnologyfordatatransmissionand onsitedataacquisition.
Asananalogmulti-sensordetector,itisfeatured withconstanttemperature andnon-differential temperature.
Withexplosion-prooffunction,mustbe equipped withLD48ooG-Arelay module.
Alarmwithblacksmoke.
JTY-GM-LD3001G
Point Smoke Detector for Household(Coded)
Features :
Twobus,on-polrity. 2nd generationof distributed smart product with embedded MCU. E-coded,taking oneaddresspointatarangeof1\~255. Alarmwithblacksmoke.
■ Asananalogsmoke detector,itcantransmit on-site smokedensityto
control unit. Analarm will issueaudible signal.
JTW-ZDM-LD3301G
PointHeatDetector for Household(A2S)(Coded)
Features:
Two bus,non-polarity. 2ndgenerationofdistributedsmart productwith embedded MCU. E-coded,taking oneaddress pointatarangeof1\~255. Asananalogsmokedetector,itcantransmiton-sitesmokedensity to control unit.
Analarmwill issueaudiblesignal.
JTY-GF-LD3902EN
StandalonePhotoelectricSmokeDetector
Features:
tandalone,poweredbythe3Vlithiumbattery,withaservicelifeforupto three years.
Afiremakesitissueaudiblesignal,andautomaticallyresetifthealarmis cleared.
It’stimetoreplacethe batterywhen lowvoltagewarns.
Self-test button.
"Silence”canbe pressed formuting thealarmsound.
Equippedwithaninfraredremotecontrol receivingdevice.Anyinfrared remotecanbeusedtoalignthered pointofthedetectortosilence thealarm, whichcanlastforoneminuteonly,afterthat,anewfirewillalarmagain.
Alarmwithblacksmoke.
Withexternal to-from ports,upto10alarmunitscan beconnected to achievesyncalarm.
Detectors
JTY-GXM-LD3410
Air-breathingSmokeDetector
Features:
■ TC twobus,on-polarity 2nd generationof distributed smart product with embedded MCU. E-coded,taking5consecutiveaddresspoints,4ofwhichcorrespond to the statusof eachchannel,andthe lastisthepublic warningaddress.
Threestatesforeachchannel:normal,fault,andalarm.
LD10G
Universal Base
Features :
Simpleandconvenienttowire,LD1oG issuitableforG-seriescoded detectors.Pleaseseeinstallationsaboutthedetectorsforapplication.
LD12G
Non-coded Universal Base
Features:
Withsimpleandconvenientwiring,LD12Gisthepreferredchoicefor JTY-GF-LD30o0G(F)PointPhotoelectricSmokeDetectorandJTW-ZDFLD3300G(F)PointHeatDetector.
LD10EN
Universal Base
Features:
Simpleandconvenienttowire,LD1oENissuitableforEN-seriescoded detectors.Pleasesee installationsaboutthedetectorsforapplication.
Manual Fire Alarm Button and Fire Hydrant Button
Manual Fire Alarm Button and Fire Hydrant Button
J-SAP-M-LD2003G
ManualFireAlarmButton
Features :
Two-bus,non-polarity,withembeddedU. E-coded,takingoneaddress pointattherangeof1\~255. Indoortype.With reusablestart parts.Usingaspecial key torestthealarm. ■ Designedwithfiretelephoneinterfacetoconnectwitha3.5telephone handle.(If the field personnel use theφ6.35 telephone handle,a specialp6.35 top3.5adaptercanbe used)
J-SAB-M-LD2003Ex
ManualFireAlarmButton (Intrinsically safe explosion proof)(Coded)
Features:
Two-bus,on-polarity,withmbeded. E-coded,takingoneaddress pointattherangeof1\~255. Explosion-proof.ALD48ooG-A relaymodule shall be connected. L Manual resetfunction,starting partscan bereused,alarmresetthrough a specialkeytocomplete.
J-SAB-M-LD2000ED
Manual Fire Alarm Button (Ex)
Features:
Two-bus,on-polarity,withembeddedU E-coded,taking oneaddresspointattherangeof1\~255. Outdoortype.Explosion proofand dust proof. Designed witha groupof passivenormally-open jointoutput. ■ Startingpartscanbereused,larmresetthroughaspecialkey tocomplete.
LD2004G
FireHydrant Button
Features:
Two-bus,on-polarity,withmbedded.
E-coded,takingone address pointattherange of1\~255.
Startingpartscanbereused,alarmresetthroughaspecialkeytocomplete.
Manual Fire Alarm Button and Fire Hydrant Button
Manual Fire Alarm Button and Fire Hydrant Button
LD2004Ex
FireHydrant Button (Intrinsicallysafe explosionproof,Coded)
Features:
Two-bus,non-polarity,withembeddedMU.
E-coded,takingoneaddress pointata rangeof1\~255.
Startingpartscanbereused,alarmresetthroughaspecialkeytocomplete.
Explosion-proof.ALD48ooG-A relay module shall be connected.
J-SAB-M-LD2002ED
Fire Hydrant Button (Ex)
Features:
Two-bus,on-polarity,withmbeddedU E-coded,takingoneaddresspointata rangeof1\~255.
Outdoor type.Explosion proof.
Designedwitha groupof passivenormallyopen jointoutput.
Startingpartscanbereused,alarmresetthroughaspecialkeytocomplete.
LD2005EN
ManualAlarmSwitch
Features:
Two-bus,on-polarity,withembeddedU.
E-coded,takingoneaddresspointatarangeof0\~255.
Startingpartscanbereused,alarmresetthroughaspecial keytocomplete.
LD20G
Manual FireAlarmButtonBase
Features:
Simpleandconvenienttowire,itisdesignedforLD2oo3G,LD2003Ex, LD2004GandLD2004Ex.
Manual Fire Alarm Button and Fire Hydrant Button
Manual Fire Alarm Button and Fire Hydrant Button
LD2100A
Outdoor Column
Features:
It isused with LD2oooED explosion-proof manual fire alarm button or LD2002ED explosion-proof fire hydrant button foroutdoor projects. 一 Designedwithanexplosion-proofconnector,itcanbedirectlyinstalled withthe explosion-proofmanual firealarmbuttonor explosion-proof hydrant button,orused withLD2200AorLD2200E. ■ Withgroundinstallation,itcanbe installedoutdoor.
LD2200A
Rain Cover
Features :
Enclosure protectionclass:IP65. Pillarinstallation,usedwithLD2100A. 1 ItcanbeusedwithLD120oG emergencyonsite start/stop button,LD2003G/ LD2003ExmanualfirealarmbuttonandLD2004G/LD2004Exfirehydrant button outdoor or indoor with protective requirements. 一 24/7 protection. 1 Equippedwithahammer forbreakingtheglass.(Note:becarefultopress and replace the glasswithoutdelay.)
LD2200C
Rain Cover(For explosion-proof products)
Features:
ItisusedwiththeLD2oooED explosion-proofmanual firealarmbuttonor LD2002ED explosion-proof hydrant buttonoutdoor or indoor with protective requirements. Additional protection for the explosion-proof manual fire alarm button or explosion-proof hydrant button.
LD2200D Rain Cover
Features:
Enclosure protection class: IP66. 1 Wall-mounted. ■ Installed with LD1200A/LD1200G on-site emergency start/stop button, LD2003G/LD2003Exmanual firealarm buttonorLD2004G/LD2004Ex fire hydrantbutton foroutdooruseorindoorwith protectiverequirements. ■ 24/7 protection. ■ Equipped witha hammer for breaking the glass.(Note:be careful to press and replace the glasswithout delay.)
LD2200E Rain Cover
Features :
Pillarinstallation,usedwithLD2100A. Install itwithLD2003G/LD2003Exmanual firealarm buttonorLD2004G/ LD20o4Exfirehydrantbuttonforoutdooruse.
Modules and Isolators
LD4400G-1
InputModule
Features:
Two-bus,non-polarity.
E-coded, taking one address pointa the range of1\~255.
One-loop passive switch joint signal isreceivable.
Todetectcircuit breakof passive switch contacts isachievable.
LD4400G-2
InputModule
Features :
Two-bus,non-polarity.
E-coded,takingtwoaddresspointsatarangeof1\~255.
Two-looppassiveswitch jointsignal isreceivable.
Todetectpassiveswitchjointcircuitbreakisachievable.
Features:
Two-bus, non-polarity. Powersupplybus,withpolrity E-coded,takingoneaddresspointatarangeof1\~255. ■ One-loop DC 24V/1.5A voltagesignalcanbeoutput. 1 Feedback input signalscan be input afterone linkage device activation.. ■ Feedback fault informationonpower busoutages,inputcircuit breaks,or output shortcircuitsorbreaks. Inputsignalcan be setasnormallyopencontact or normallyclosedcontact input,while outputsignal aslevel output or pulseoutput.
Features:
1 Two-bus,non-polarity. Powersupplybus,withpolarity. E-coded,takingtwoconsecutiveaddress pointsatarange of1\~255.
1 Two-loopDC 24V/1Avoltage signalcanbe output. Feedback input signalscan be inputafter two linkage devicesactivation..
? Feedback fault informationon powerbusoutages,inputcircuit breaks,or
input short circuitsor breaks.
Inputsignal can besetasnormally-opencontact or normally-closed contact input,while outputsignalaslevel output or pulse output.
Modules and Isolators
LD6804G
Output Module
Features :
Two-bus,o-polrity Power bus,with polarity. E-coded,takingoneaddresspointata rangeof1\~255. Receive start/stopcommandsfromcontrol unitsand switchthe outputs. Feedbackfaultinformationon externalcircuitbreaksorshortcircuits. ■ Feedback fault informationonany cable breaks or short circuitsof fire speakers.
LD6804GT
OutputModule
Features:
Two-bus,non-polarity.No external DC 24V. E-coded,takingoneaddresspointata range of1\~255. Receive start/stopcommandsfromcontrol unitsand switch the outputs. Feedbackfaultinformationonexternalcircuitbreaksorshortcircuits. Feedback fault informationonanycable breaksor shortcircuitsof fire speakers.
LD6801GK
Input/Output Module
Features:
Two-bus,non-polarity.No external DC24V.
E-coded,takingoneaddresspointatarangeof1\~255.
One-looppassive normally open contact.
Feedback inputsignalscan beinputafterone linkagedeviceactivation..
Feedback faultinformationoninputlinebreaksoroutputlineshorts.
LD6801GM
Input/OutputModule
Features:
Two-bus,non-polarity.No external24V.
E-coded,taking one address pointatthe rangeof1\~255.
One-loop active output signal (pulse output).
Feedback inputsignalcanbe inputafterone linkagedeviceactivation.
Feedback fault information on input line breaksoroutput line shorts.
Modules and Isolators
LD6801GP
Input/OutputModule
Features :
Two-bus,with polarity.NoexternalDC24V.
E-coded,takingone addresspointatarange of1\~255.
One-loopactiveoutputsignal(level output).
Feedback inputsignalscan be inputafterone linkagedeviceactivation..
Feedbackfaultinformationon input line breaksoroutput lineshorts.
LD6803G
Input/OutputModule
Features:
ItisusedwithD9203EN-T/T1linkageoutputactivatingend,witholarity. No external24V.
Non-coded,doesnotccountortheddresspoint,correspondingtohe addressof themulti-wire panel.
One loop DC24V/0.1A voltage signal (1.0A/200ms pulse signal will be provided during initializing).
Oneloop passive switch on/off signal.
Themodulereturnsafeedbacksignalwhenthe inputlineisshortcircuited.
The module returnsa fault signal when the input line is broken or the output lineisshortcircuitedorbroken.
LD4900G
RelayModule
Features:
Two-bus,non-polrity. E-coded,takingoneaddresspointatarangeof1\~255. Each input module cancarry 1\~20 non-coded heat detector(s) or 1\~10 noncoded smoke detector(s). Detectcircuitbreaks.
LD4401G
RelayModule
Features:
Two-bus,non-polarity. Power bus,with polarity. E-coded,taking oneaddress pointata range of1\~255. With one set of power supply output.
■ Oneanalog input signalscan be received,judging the module states based
on signal values. Fordetectives,suchasexternal circuit breaksorshortcircuits. Receiveswitchon/offsignals,itisused withtemperaturesensingcable.
Modules and Isolators
LD4800G-A
RelayModule
Features:
Two-bus,non-polarity.
DC24V,withpoarity
Withouttakinganyaddresspoint.
EachLD48o0G-A could carry1\~10 e-coded explosion-proof smoke/heat detector(s)or 1\~10 explosion-proof manual fire alarm button(s)/fire hydrant button(s).
Electronic isolation betweentwo-bus,DC24Vandoutputbus.Highantiinterferenceandstableoperation.
Asabest practice,install explosion-proof detectorsand explosion-proof manualfirealarmbuttonwithin500metersfromaLD48ooG-A.
LD4800G
RelayModule
Features :
Two-bus,non-polarity. DC24V,ithiy Electronicisolation betweentwo-bus,DC24Vandoutputbus.Highanti interference and stable operation.
Asabest practice,install explosion-proof productswithin5o0meters froma LD4800G.
LD6806G
RelayModule
Features:
Two-bus,non-polarity,withouttakinganyddresoint.
Powersupply,itholrity.
Isolatedsignalrelayfeature,outputcapacityupto750mA.
Shortcircuit and overload protection foroutput.Self restored.
LD6806G-L
RelayModule
Features:
Two-bus,withpolarity.
E-coded,taking oneaddresspointatarangeof1\~255.
Itisachievable to expandthe inputbusloop intoringloop,with two-loop output forringconnecting.
Allinternaldevicesstilloperatenormally,eventhereisabreakinthering loop.
Short-circuitprotection.Self restored.
Modules and Isolators
LD6810/LD6811
RelayModule
Features :
Powersupplybus,withpolarity Communication port:optic fiberoutput. 1 Optical fiber port:SC. Optical cable:single-mode quartz. Opticalfiberattenuation:absolutevalueisnot greaterthan13dBm. Longest communicationdistance:40Km. Output1DC24V/1.5A voltagesignal isachievable (LD6811). ■ The feedback input signal afterone linkage device activationcan be input (LD6811). 1 Monochrome indicator displays module status. ■ Onceinputline breaks,outputline shortsor breaks,themodule will feedbackfaultinformation.
LD3600G
BusShortCircuit Isolator
Features :
Two-bus,on-polaritywithouttakingnyddresint.
No external power supply is required.
Unidirectional.
LD3600G-L
Bidirectional ShortCircuitIsolator
Features :
Two-bus,with polarity. It is used with LD6806G-L relay module in a ring loop, Eventhere isa break inthering loop,operationofallinternal devices is normal. Output short-circuit protection and restorable.
LD3600A-5A/LD3600A-10A
DCPower Short Circuit Isolator
Features:
1 Foranoccasion wheremultiple fire control devicesare supported by one fire power supply (DC 24Vwitha high power).
Quicklycutoffthe firecontrolequipmentwithaDCoverload inputorshort circuittoavoidaffectingthenormaloperationofotherdevices.
■ PowerDC24Vwilllightthe inputpowerindicator;andthestartof the powerswitchwilllight theoutput power indicator,whichwillbe offwhenthere isanoverloadorshortcircuit protection,lightingthe protectionindicator.Once theprotectionisactivated,theresetmustbeoperated manually(through the power switch).
LD60G Module Base
Features:
Simpleandconvenienttowire,thebaseissuitableformoduleproductsofG series.Seemountingmethodsfordetails.
Audible/VisibleAlarms
Audible / Visible Alarms
LD1000G
Audible/VisibleAlarm(Coded)
Features:
Two bus,non-polarity.
Power supply bus,non-polarity.
E-coded,taking oneaddress pointata range of0-255.
Thefailureof powerwill feedback itsfault informationtocontrol unit.
Feedback its information tocontrolunitautomaticallyafter initiating.
LD1002G
Audible/VisibleAlarm(Two-wiresystem,coded)
Features:
Twobus,non-polarity.No external DC 24V powersupply isrequired. E-coded,taking one address pointatarange of1\~255.
1 Automaticfeedbacktothecontrolunitafterstartup.
■ Thelightkeepsflashingwhenalternatingwith broadcast,andthe sound and
thebroadcast proceedalternately. Itisused with all ourcontrol units.
LD1002G(F)
Audible/VisibleAlarm(Two-wiresystem,non-coded)
Features:
Powersupplybus,non-polarity. Non-coded,withouttakingnyddressoint L Itcanbe used formulti-wireaudible/visibleoutput forcontrol units,orit is usedwithourLD68ooG-1input/outputmoduleorothers,toissuewhitevisible signalandalarmwhen 24V voltage isoutput fromthecontrol device.
LD1102G
VisibleAlarm
Features:
Twobus,non-polarity.Noexternal DC24 powersupplyisrequired.
E-coded,takingoneaddresspointata range of1\~255.
Feedbackinformationtocontrolunitautomaticallyafteractivation.
Audible/VisibleAlarms
LD1002Ex
Audible/VisibleAlarm(Ex)
Features:
Twobus,non-polarity.No external DC24 powersupplyisrequired.
E-coded,takingoneaddresspointatarangeof1\~255.
Feedbackinformationtocontrolunitautomaticallyafteractivation.
LD1000ED
Audible/VisibleAlarm(Ex)
Features :
Twobus,non-polarity,withspecial embeddedU.
DC24V twobus,non-polarity.
E-coded,takingoneaddresspointatarangeof1\~255.
Installedoutdoor,withexplosion-proofuncion.
Canbesetupfor useasannon-coded fireaudible/visual alarm.
LD1001Y
Audible/VisibleAlarm(Voice type)
Features:
Two bus,non-polarity. Powersupplybus,non-polarity. 1 E-coded,takingoneaddresspointatarangeof1\~255. 1 Thefailureof powerwill feedback itsfault informationtocontrolunit. ■ Itsactivationwillissuealarmand voice."Here isa fire,pleaseevacuate immediately!"willbe broadcast ina loop.At the beginningof thebroadcast, thesound pressurelevel islessthan 45dB,and then gradually increases to no less than 75dB.
LD11EN
BaseforAudible/VisibleAlarm
Features:
Simpleandconvenienttowire,itisagoodbaseforaudible/visiblealarm andvisiblealarm.
Fire Display Panel
LD128E(T)-C FireDisplay Panel (Two-wire)
Features :
Twobus,non-polarity.Noexternal DC24V powersupplyisrequired. E-coded,takingone addresspointatarange of1\~255. ■ The160\*160LCD,ChineseandEnglishversioncanbeswitchedflexibly. Each piece of record can display sixteencharactersdescriptive Chinese informationand eightcharactersdevice types. L Thedisplayrangesanddetailscanbesetbythe panel,withsixdisplay rangesperpanel,withineachdisplayrangetheaddressofthedetectorcanbe separateorcontinuous. ■ Eachpaneldisplaysamaximumof512firealarminformationand512 fault information,whichcanbedisplayedcross loop. ■ Theall-displaymodecouldbesettodisplayallthefireand fault information. ■ EquippedwiththeUSB portfordataimport. ■ Allfire display panelsoffull network use the same data to display full networkfirealarminformation. ■ Itisused with all ourcontrol units.
LD128E(T)-DFireDisplay Panel(Two-wire)
Features:
Twobus,non-polarity.NoexternalDC24V powersupplyisrequired. 1 E-coded,takingoneaddresspointatarangeof1\~255. 1 Fourdisplayrangescan beset,and withineachdisplay range theaddress of thedetectorcan be separateorcontinuous. 1 Eachpanel displaysamaximumofthefirst99faultinformationand99fire alarminformation Supporting cross loop or cross host display. 一 Thedisplayedrangeoffloorand part,respectively from1\~127and1\~255, bothneed to be set in the control unit. 一 Itisusedwithallourfirealarmcontrolunits.
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
JB-QG-LD128E2-T
FireAlarmControlUnit/FireLinkageControlUnit
Features:
■ Asacentralizedregionalcontrolunitwithcompatibility,itisdesignedwith the peer-to-peer network structure (with no master or slave),with each control unitdisplayingperformancesofall devicesinthenetwork.
■ Itsmassive-scale standalone capacity:32 loops(maximum),5120 address points (maximum),59 multi-line directoutput points,and512 bus output points.
■ Itsnetworkcapacity:64control units,256loops,and 65536address points. ■ 12.1-inchcolorfulLCD touchscreenand statusindicators.
■ Convenient and flexible touchscreen,external mouse and keyboard support. ■ Chineseand English twoversions.
■ Supporttosetandoperateindifferentzones,writinglinkagealarmand output devices in one or multi zone(s) for linkage simplification.
■ ItsCANBusport isused for networkingotherdevicesvia LD69o0series communication conversion cards.
■ Withthe ARM-based RISC embedded CPU,low powerconsumption,fast processingspeed,and stableoperation.
■ Withthe real-time preemptive multitasking embedded operating system, responsive.
■ Withtheblackboxfunction,itstoresamaximumof1oooalarmrecords, 1000 devicefaultrecords,1oo0request records,1oo0startrecords,1000 feedbackrcords,0o0oerationrecords,0o0monitoringrecords,0gas extinguishingrecords,10ooother faultrecords,and1oo0 runningrecords. ■ Alarmsupervision.
■ Short-circuit protection both intheloop and in the power supply.
□ Optional two-wireor three-wire to output multi-line,but needs to be connected to LD6803G module when output two-wire.
■ Busoutputcurrentupto1.3A.Enableconnectwithourtwo-wireand fourwire bus products.
JB-QT-LD128E2-T
FireAlarmControlUnit/FireLinkageControlUnit
Features:
Asacentralizedregionalcontrolunitwithcompatibility,itisdesignedwith the peer-to-peer network structure (with nomaster or slave),with each control unitdisplaying performancesofall devicesinthe network. ■ Itsmassive-scale standalone capacity:32 loops (maximum),5120address points (maximum),159multi-linedirectoutput points,and512busoutput points. ■ Itsnetwork capacity:64control units,256loops,and 65536address points. ■ 12.1-inch colorful LCD touchscreen and status indicators. ■ Convenientandflexible touchscreen,external mouse and keyboard support. ■ Chinese and English two versions. ■ Support toset and operate indifferent zones,writing linkage alarmand output devices in one or multi zone(s) for linkage simplification. 1 ItsCANBusportisusedfornetworkingotherdevicesviaLD69o0series communicationconversion cards. ■ Withthe-basedIsCembeddedU,lowowerconsumpionast processingspeed,and stableoperation. ■ Withthe real-timepreemptivemultitasking embedded operatingsystem, responsive. ■ Withtheblackboxfunction,itstoresamaximumof1oooalarmrecords, 1000devicefault records,1o0 requestrecords,0o0start records,1000 feedback records,oo0erationrecords,oo0monitoringrecords, a extinguishingrecords,10ooother fault records,and1oo0 running records. ■ Alarm supervision. ■ Short-circuit protection both in theloopand in the power supply. ■ Optional two-wireorthree-wire tooutputmulti-line,butneeds tobe connected to LD6803G module when output two-wire. ■ Busoutputcurrentupto1.3A.Enableconnectwithourtwo-wireand fourwire bus products.
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
JB-QG-LD988EL
FireAlarmControlUnit/FireLinkageControlUnit
Features:
■ Asacentralizedregional control unit withcompatibility,itisdesignedwith thepeer-to-peer network structure (with nomaster or slave),with each control unitdisplayingperformancesofalldevicesinthenetwork.
■ Massive-scalestandalone capacity:20 loops (maximum),5120ddress points (maximum),168 multi-line direct output points,and 512 busoutput points.
■ Networkcapacity:64control units,256loops,and65536addresspoints. ■ Witha7-inchcolorfulLCD touchscreenand status indicators.
■ Supporttosetandoperateindifferent zones,writinglinkagealarmand outputdevicesinone ormulti zonefor linkage simplification.
■ ItsCANBusport isused fornetworkingotherdevicesviacommunication conversion card.
1 UsePC software to program the configuration data,which can be uploaded anddownloadedwithaUSBdisk.
■ Withmulti-taskbuilt-inoperationalsystem,responsefast.
■ Withthe functionofblack box,total 256oo records,including fire,fault, supervisionand feedbackcanbestored.
■ Supervisedalarm.
■ Short-circuit protection both in the loop and in the power supply.
■ Thewiringof two-wire(LD6803moduleisrequired) orthree-wireis compatible.
■ Bus output current up to1.3A.Enable towith our two-wireand four-wire bus products.
JB-QT-LD988EL
FireAlarmControlUnit/FireLinkageControlUnit
Features:
■ Asacentralizedregionalcontrolunitwithcompatibility,itisdesignedwith the peer-to-peer network structure(with no master or slave),with each control panel displayingperformancesofalldevicesinthe network.
■ Massive-scale standalone capacity:20 loops (maximum),5120 address points (maximum),168 multi-line direct output points,and 512 bus output points.
■ Networkcapacity:64control units,256loops,and 65536addresspoints. ■ Witha7-inchcolorful LCD touchscreenand statusindicators.
■ Supporttosetand operateindifferent zones,writinglinkagealarmand outputdevices inone or multi zone for linkage simplification.
■ ItsCANBus port isused for networking otherdevicesviacommunication conversioncard.
■ UsePC softwareto programtheconfigurationdata,whichcan beuploaded anddownloadedwitha USBdisk.
■ Withmulti-task built-inoperational system,response fast.
■ Withthe functionofblack box,total256o0 records,including fire,fault, supervisionand feedbackcan be stored.
■ Supervised alarm.
■ Short-circuit protection both in the loop and in the power supply.
1 Thewiringof two-wire (LD68o3G module is required) or three-wire is compatible.
■ Busoutputcurrent up to1.3A.Enable towith our two-wireand four-wire bus products.
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
JB-QB-LD988EM
FireAlarmControl Unit/FireLinkageControl Unit
Features:
Acentralizedregional controlunitwithcompatibility. ■ Standalonecapacity:2loops,255addresspoints(maximum),and510 points (maximum) for the system. L Witha3.5-inch LCD touchscreenand statusindicators. ■ ItsCANBusport isused for networking otherdevices via communication conversioncard. ■ UsePC softwaretoprogramtheconfigurationdata,whichcanbeuploaded anddownloadedwithaUSBdisk. 1 Withthefunctionofblack box,totalooorecords,includingfire,fault, supervisionand feedbackcanbestored. ■ Thecontrolunithas3levels,thedefaultbootlevel isO,entera password in themenu toswitch tothe specified permission level. □ Short-circuit protection both in the loopand in the power supply ■ Two-wiresystem,LD6803G module isrequired. L Busoutputcurrentupto680mA.Enabletowithourtwo-wireand four-wire bus products.
JB-QB-LD988ENM
FireAlarmControlUnit/FireLinkageControlUnit
Features:
1 Zone firealarmcontrol unit.
■ Standalone capacity:8 loopsat maximum,2048addresspoints (maximum), and comes with8 multi-line direct control output points.
■ Witha 7-inchLCDtouchscreenandstatusindicators.
■ Supporttosetand operateindifferent zones,writinglinkagealarmand output devices in one or multi zone(s) for linkage simplification.
ItsCANBusport isused fornetworkingotherdevices viacommunication conversion card.
■ UsePC software toprogramtheconfigurationdata,whichcanbeuploaded anddownloadedwithaUSBdisk.
■ Withmulti-task built-inoperational system,response fast.
■ Withthefunctionofblackbox,total256oo records,including fire,ault, supervisionand feedbackcan be stored.
■ Supervised alarm.
■ Short-circuit protection both inthe loopand inthepowersupply.
■ Thewiringof two-wire(LD68o3G module isrequired) orthree-wireis compatible.
■ Busoutputcurrentupto1.3A.Enabletowithourtwo-wireandfour-wire bus products.
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
JB-QB-LD307
FireAlarmControlUnitforHousehold
Features:
Local capacity:one loop. 1 ItisdesignedwithChineseoperationinterfacein3.5inchesfullChinese LCDand status indicators. ■ With two loops passive joint output. ■ Withthefunctionof blackbox,itstoresamaximumof2oofirealarm records,2oofaultrecordsand2o0othersrecords. ■ Externaldevicefirealarminformationorfaultinformationcanbereceived through the bus. ■ Short-circuit protection both inthe loopand power supply. ■ Enabletoconnecttothe firealarmcontrol unitthroughthe twobus. Therearesingleaddresspointormultipleaddresspointsoptional modes,and multiple addressesaccount foratleast fouraddresses (three control units and one external busdevice),and at most nineteenaddresses (three control units andsixteenexternalbusdevice) ■ Usethe specialsoftware toprogramtheconfigurationdata and download theconfigurationdata viaUSBdisk,whichcan facilitateeditingofdevice type switch,riiooiooe. ■ Mobilecommunication SIMcard is needed for dialing thepreset two groups of phonenumbersafterthe firealarm,andthenumberofloopdialingcanbe set. D DC24V powersupplyisusedasthemainpowerofthesystemwithspecial wall-mounted powersupplyWK-BII10,whicheedstoconnecttotwous, withtakingfortwoaddresspoints.
LD9203EN
Linkage Control Panel
Features:
WithCANBusanddual-RS232communicationmodes,itisusedwithall our control panelsvia CANBus. Each panel controlsa maximum of32-loop bus or multi-line output devices. □ Multi-lineoutputboard canbeconfigurated formulti-wireoutputcontrol. □ Keyboard lockable. ■ Astart/stopbuttonand three statusindicators (start,feedbackand fault)for each loop. ■ Featurewire fault detection ineach loop of the multi-wire panel. Upto1A drivecapabilityineach loopof multi-wireoutput panel.Maximum output current of multi-line output boards is 5A. ■ Itisused with LD92EN-T1(two-wire/three-wire systemeight loopsmultiline output panel). ■ Themulti-wireoutput panel can beconnected withthecontrolled equipment in three-wire or two-wire system throughdialing the switch,and theLD6803G moduleisrequired inthetwo-wiresystemconnection.
LD9204EN
Linkage Control Panel
Features:
WithCANBusanddual-RS232communicationmodes,itisusedwithall
ourcontrol unitsvia CANBus. Upto128 loopsbuscan becontrolled for eachdevice. Astart/stopbuttonandthreestatusindicators(start,feedbackand fault)for
each loop. Keyboard lockable.The keyboard isautomaticallylocked withnokeystroke
duringacertaintime. Itisdesignedwithaunlock keyandanallowed statusindicator.
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
LD5804EN
Linkage Power Supply
Features:
Speciallyequipped for linkagecontrolcabinetsystem. The power supplyconsistsof 22oVACand batteries,which forman uninterruptibleoutput power supply.Themain poweroutput takes precedence. Whenthemain power fails,the power supplyautomaticallyswitches tothe batteries. ■ Support linkage output and control output, whichare common ground output. 1 Linkage output providestherequired voltagewhenthe linkagecontrol device (control module,direct control output) isoutput. Themainpowersupplyvoltageoflinkageoutputis25V±1V,whilewhenthe batteryisworking,thevoltagedecreaseswiththebatteryvoltage. □ Control output provides power supply for cabinetand two busdevices. ■ Thecontrol output voltagecan be stabilized beforeandafterthemain power/batteryswitchover. ■ Fault signal output of main power andthe battery. 1 Batterymanagement. ■ Batteryundervoltagealarm. ■ Battery protection: the output willbe turned off when the discharge undervoltage,soas toavoid battery overdischarge and scrap. 1 Output overload andshortcircuit protection.
HC-600FM2B
Linkage Power Supply
Features:
Specially equipped for linkagecontrol cabinet system. 1 Thepowersupplyconsistsof22oVACand batteries,which forman uninterruptibleoutput power supply.Themain power output takesprecedence. Whenthe main power fails,the power supplyautomaticallyswitches to the batteries. ■ Support linkage output and control output, whichare common ground output. Linkageoutputprovidestherequired voltagewhenthelinkagecontrol device(control module,direct control output) isoutput. Themainpowersupplyvoltageoflinkageoutputis27V±1V,whilewhenthe batteryisworking,thevoltagedecreaseswiththebatteryvoltage. 1 Controloutput providespowersupply forcabinetand twobusdevices. ■ Thecontrol outputvoltagecan be stabilized beforeandafterthe main power/batteryswitchover. Fault signal output of main power and the battery. 1 Batterymanagement. 1 Batteryundervoltagealarm. ■ Battery protection: the output will be turned off when the discharge undervoltage,soas toavoid battery overdischargeandscrap. ■ Output overload and short circuit protection.
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
Fire Alarm Control Unit, Linkage Control Panel and Linkage Power Supply
LD5120EN
Linkage Power Supply
Features:
Speciallyequipped for linkagecontrolcabinetsystem. Thepowersupplyconsistsof22oVACandbatteries,whichforman uninterruptible output power supply.The main power output takes precedence. Whenthemain power fails,the power supplyautomaticallyswitches to the batteries. 一 Linkageoutput providesthe requiredvoltagewhenthe linkagecontrol device (control module,directcontrol output) isoutput. 一 Themainpowersupplyvoltageoflinkageoutputis27V±1V,whilewhenthe batteryisworking,thevoltagedecreaseswiththebatteryvoltage. 1 Fault signal output of main power and the battery. ■ Batterymanagement. ■ Batteryundervoltagealarm. ■ Battery protection:the outputwill be turned off when the discharge undervoltage,soas toavoid battery overdischarge and scrap. ■ Output overload and shortcircuit protection.
WK-ND20
Linkage Power Supply
Features:
1 Speciallyequipped for linkagecontrolcabinetsystem.
L Thepowersupplyconsistsof2oVACand batteries,which forman
uninterruptibleoutputpowersupply.Themainpoweroutputtakesprecedence. Whenthe main powerfails,the power supplyautomaticallyswitches tothe batteries.
■ Linkage output providesthe required voltagewhen the linkage control device (control module,direct control output) isoutput.
1 Themainpowersupplyvoltageoflinkageoutputis27V±1V,whilewhenthe battery isworking,the voltagedecreaseswiththebatteryvoltage.
1 Batterymanagement.
■ Batteryundervoltagealarm.
■ Battery protection: the output will be turned off when the discharge
undervoltage,soas toavoidbattery overdischargeand scrap.
■ Output overload and shortcircuit protection.
Fire Emergency Broadcast System
YJG4590
Zone Control Panel
Features:
Control 90 loopsin busmode emergency broadcast output.
Detect zone linesinrealtime,andalarmwhenthereisanopenorshort circuit.
Multiplecontinuousareascanbesetasalogicalonetofacilitateactivation orincreasebroadcastpower.
Associationstatuscanbe set forsynchronizing broadcastofoneareaand its connected areas.
1Monitoringthe broadcastoutput signal.
Self-testand faultsilence.
Modecanbe setasautomaticor manual.
Connected tocontrol unit via CANBus for automatic control.
Itsinternal signal portallowssignalconnection between broadcast amplifiers.
Intheautomaticstate,the control unitcan be linked to realize the alternatingworkingmodeofsoundandlightalarmandbroadcast,inthis workingmode,thetime-sharingandalternatingworkingof the firealarm systemcan be realized.
Upto2poweramplifiercanbeaccessedforYJG4590bus1,while4for YJG4590 bus 2.