CONVEYORS Information about belts and chains
A-97
Belt brand MITSUBOSHI Bando Chinese brand
F
Ordinary, green NS41UG0/2G SL-M2300 08/01BGDU
G
Sliding, green NS41UG0/0G SL-M5302 08/02BGDU
S
Sliding, white NS41UG0/0 SL-M5100 08/02WDU
D
Anti-static, black NS41UG0/2BK SL-S3726 -
F
Food grade, white NS41UFG0/2W SL-F1100 -
O
Oil resistant NS41UEG0/2G SL-SY534R -
T
High-temperature
resistant
NS15FK - -
Belt brand MITSUBOSHI Bando Chinese brand
F
Ordinary, green NS82UG0/2G SL-M2401N 15/01BGDU
G
Sliding, green NS82UG0/0G SL-M5402N 15/02BGDU
S
Sliding, white NS82UG0/0 SL-M5200N 15/02WDU
D
Anti-static, black NS82UG0/2BK SL-S3827 -
F
Food grade, white NS82UFG0/2W SL-F1201 -
O
Oil resistant NS82UEG0/2G SL-S2634 -
T
High-temperature
resistant
NS15FK - -
L
Inclined, green NS82UKG0/8GT SL-M9400R -
<For CSJ30> <For CSSK50>
◼ Calculation method of belt and chain length
◼ Flat belts
Conveyor model Calculation formula of
length Unit Remarks
CSJ30-A 2L+90 mm
CSJ30
2L+274 mm
When the sprocket spacing is below
2,000mm
2L+258 mm
When the sprocket spacing is
2,000mm or above
2L+284 mm
Knife-shaped transition rollers on
both sides
2L+279 mm
Knife-shaped transition roller on only
one side
CSSK50-A 2L+150 mm
CSSK50-M 2L+331 mm
CSP50G-MM-L (2L+155) ÷9.525 Link
The value with decimals should be
rounded up/down to a whole number;
the even number of chain links
should be taken for the calculation
CSP50G-DR-C (2L+276) ÷9.525 Link
The value should be rounded
up/down to a whole number; the
even number of chain links should be
taken for the calculation
CSP50G-DR-L (2L+155) ÷9.525 Link
The value should be rounded
up/down to a whole number; the
even number of chain links should be
taken for the calculation
CSSP60-A 2L÷12.7+15 Link The value with decimals should be
rounded up/down to a whole number
CSP89B-MD 2L÷12.7+23 Link
The value with decimals should be
rounded up/down to a whole number;
for the iron chain with a resin cover,
the even number of chain links
should be taken for the calculation
CSP89B-D 2L÷12.7+23 Link
The value with decimals should be
rounded up/down to a whole number;
for the iron chain with a resin cover,
the even number of chain links
should be taken for the calculation
CSB80A 2L÷10+25 Tooth The value with decimals should be
rounded up/down to a whole number
Conveyor model Calculation formula of
length
Unit in
grams
Remarks
CSB30A-MD 2L÷5+20 Tooth The value with decimals should be
rounded up/down to a whole number
CSB30A (2L+255) ÷5 Tooth The value with decimals should be
rounded up/down to a whole number
CSB50A-MD 2L÷10+16 Tooth The value with decimals should be
rounded up/down to a whole number
CSB50A-M (2L+324)÷10 Tooth The value with decimals should be
rounded up/down to a whole number
CSSB60-A 2L÷10+18 Tooth The value with decimals should be
rounded up/down to a whole number
CSSB60-M 2L÷10+46 Tooth The value with decimals should be
rounded up/down to a whole number
CSB89A-MD/D 2L÷9.525+30 Tooth The value with decimals should be
rounded up/down to a whole number
CSW61A-MD/D 2L÷12.7+15 Link
The value with decimals should be
rounded up/down to a whole number;
the even number of chain links
should be taken for the calculation
CSSW62A-D/DR/DU (2L+196)÷19.05 Link
The value with decimals should be
rounded up/down to a whole number;
the even number of chain links
should be taken for the calculation
CSW62A/G-MD/D (2L+288)÷19.05 Link
The value with decimals should be
rounded up/down to a whole number;
the even number of chain links
should be taken for the calculation
CSW62A-M (2L+472)÷19.05 Link
The value with decimals should be
rounded up/down to a whole number;
the even number of chain links
should be taken for the calculation
CSQ88-D 2L÷38.1+7 Link The value with decimals should be
rounded up/down to a whole number
CSC53G 2L÷12.7+13 Link The value with decimals should be
rounded up/down to a whole number;
the even number of chain links
CSC96A 2L÷15.875+18 Link should be taken for the calculation
Attention
1. Precautions for the height of the conveying surface
The height of the conveying surface described in the external dimensions drawing in this document refers to the height from the floor
to the conveying surface (upper surface of belt or chain). If the thickness of the belt or the outer diameter of the chain changes, the
dimensions will change accordingly, so please pay special attention to this.
2. Precautions for matters other than those listed in the belt type column
In the case of using a belt, the belt itself will be limited by its minimum bending radius. When you choose a conveyor, attention should
be paid to the selection of a suitable pulley diameter.
The load-bearing plates of GNKE's conveyors generally use stainless steel plates or sticky steel plates, which are not suitable for
belts with steel plate as the bearing plate, so please do not use them.
3. Precautions for the conveying direction
The conveying direction of the belt is specified. When the customer chooses to install the belt themselves, please pay attention to the
conveying direction.
The calculation formulas for the length of the belt and chain are recorded in the table below. Please inquire according to actual needs
when designing or maintaining.
• Sliding belts are generally suitable for occasions where workpieces are stranded on the conveyor.
• Anti-static belts are suitable for conveying the electronic parts, but only the surface of the belt is anti-static.
• Food-grade belts are suitable for unpackaged food, but only limited to dry food at room temperature. When they are used to convey wet or
hot food, special measures are required. Please ask and confirm with us first before placing an order.
• Oil-resistant belts are suitable for normal temperature conditions where oil is attached to the workpieces. When there is high heat or a large
amount of corrosive oil, please contact us in advance.
• Heat resistance range of high-temperature resistant belt is ‐40°C~180°C.
Motor type CONVEYORS
Oriental Motor
◼ Wiring diagram of induction motor
Single-phase 110V/single-phase 220V Three-phase 200V/220V, three-phase 380V
Lead wire type Terminal box type Lead wire type Terminal box type
Clockwise Clockwise Clockwise Clockwise
Counterclockwise Counterclockwise
K series motors
Counterclockwise
If the positions of any two power lines
among R, S, and T are exchanged, the
motor will rotate counterclockwise.
200W BH series motors
Single-phase 110V/single-phase 220V Three-phase 200V/220V, three-phase 380V
Lead wire type Terminal box type Lead wire type Terminal box type
Reduction ratio: 3~9
Reduction ratio: 50~180
Reduction ratio: 3~9
Reduction ratio: 50~180
Reduction ratio: 3~9
Reduction ratio: 50~180
Reduction ratio: 3~9
Reduction ratio: 50~180
Clockwise Clockwise Clockwise Clockwise
Counterclockwise Counterclockwise
Reduction ratio: 12.5~36 Reduction ratio: 12.5~36 Reduction ratio: 12.5~36 Reduction ratio: 12.5~36
Clockwise Clockwise Clockwise Clockwise
Counterclockwise Counterclockwise
<Tandem type, with parallel shafts>
Counterclockwise
If the positions of any two power lines
among R, S, and T are exchanged, the
motor will rotate counterclockwise.
Counterclockwise
If the positions of any two power lines
among R, S, and T are exchanged, the
motor will rotate counterclockwise.
Counterclockwise
If the positions of any two power lines
among R, S, and T are exchanged, the
motor will rotate counterclockwise.
Counterclockwise
If the positions of any two power lines
among R, S, and T are exchanged, the
motor will rotate counterclockwise.
<Round shaft type>
Counterclockwise
If the positions of any two power lines
among R, S, and T are exchanged, the
motor will rotate counterclockwise.
A-98
Capacitor
Motor
White
Red
Black
Capacitor
Motor
White
Red
Black
Motor
Red
White
Black
Capacitor
Motor
Capacitor
Motor
Motor
Motor Motor Motor Motor
Motor Motor
Motor Motor
Motor Motor
Motor Motor
Capacitor Capacitor
Capacitor Capacitor
Capacitor Capacitor
Capacitor Capacitor
White
Red
Black
White
Red
Black
White
Red
Black
White
Red
Black
White
Red
Black
White
Red
Black
Motor type CONVEYORS
Oriental Motor
Single-phase 110V/single-phase 220V Three-phase 200V/220V, three-phase 380V
Lead wire type Terminal box type Lead wire type Terminal box type
Clockwise Clockwise Clockwise Clockwise
Counterclockwise Counterclockwise
<Tandem type, with orthogonal shafts>
Counterclockwise
If the positions of any two power lines
among R, S, and T are exchanged, the
motor will rotate counterclockwise.
Counterclockwise
If the positions of any two power lines among
R, S, and T are exchanged, the motor will
rotate counterclockwise.
(Note) For the hollow shaft type, the rotation direction of the output shaft differs
depending on the mounting surface.
Single-phase input voltage Three-phase input voltage
◼ Wiring diagram of inverter of induction motor
Power
Motors
CW
CCW
Motors
Power
CW
CCW
A-99
Capacitor
Motor
White
Red
Black
Capacitor
Motor
White
Red
Black
Motor
Red
White
Black
Capacitor
Motor
Capacitor
Motor
Motor
Gear flange
Gear flange
Motor type CONVEYORS
Oriental Motor
30W, 60W, 120W 200W, 400W
Single-phase voltage Three-phase voltage Single-phase voltage Three-phase voltage
< 30W, 60W, 120W>
◼ Wiring diagram of brushless adjustable-speed motor
BMU series motors
◼ Wiring diagram of adjustable-speed motor
US series motors
Single-phase 110V/single-phase 220V
6W, 15W, 25W, 40W 60W, 90W
In the case of continuous operation In the case of continuous operation
In the case of forward and reverse operation In the case of forward and reverse operation
< 200W, 400W>
A-100
Back of speed
governor Back of governor
Whit
e
Whit
e
Black
Black
Power Power
Ground Earthing
Single-phase 110/115V
Single-phase 220/230V
Single-phase 110/115V
Single-phase 220/230V
Capacitor
Ground (grounding wire: green)
Ground (grounding wire: green)
When connected according to the diagram above, the motor shaft rotates clockwise.
When it is connected to the dotted line position, it will rotate counterclockwise. When connected according to the diagram above, the motor shaft rotates clockwise.
When it is connected to the dotted line position, it will rotate counterclockwise.
Single-phase
110/115V
Single-phase
220/230V
Single-phase 110/115V
Single-phase 220/230V
Capacitor
Contact capacity of switch
The inductive load is above 5A in the event of AC250V
Contact capacity of switch
The inductive load is above 5A
in the event of AC250V
⚫ Single-phase 100-120V ⚫ Three-phase 200-240V
⚫ Single-phase 200-240V
• Single-phase 100-120V
• Single-phase 200-240V
• Three-phase 200-240V
L1, L2, and L3 are displayed only
for the 400W type.
Sensor connector (CN3)
Connect the sensor connector
(black) of the motor.
Input/output signal
connector (CN4)
Connect input/output signals.
[Back side of driver]
Motor connector (CN2)
Connect the connector (white) of
the motor.
Main power connector (CN1)
Connect main power.
Protective ground terminal
(2 places)
Be sure to ground one of the
protective ground terminals.
Sensor connector (CN3)
Connect the sensor connector
(black) of the motor.
Input/output signal
connector (CN4)
Connect input/output signals.
[Back side of driver]
Motor connector (CN2)
Connect the connector (white) of
the motor.
Main power connector (CN1)
Connect main power.
Protective ground terminal
(2 places)
Be sure to ground one of the
protective ground terminals.
Motor type CONVEYORS
Single-phase 110V/single-phase 220V Single-phase 220V input voltage
Switch and relay control Inverter control
Three-phase 200V/220V, three-phase 380V
Switch and relay control
JSCC Motor
◼ Wiring diagram of induction motor
YS series motors
◼ Wiring diagram of adjustable-speed motor
YT series adjustable-speed motors
Single-phase 110V/single-phase 220V
6W ~ 200W
(Note) The capacity of the switch \"K\" contact is not less than 10A.
A-101
Power
supply
Single-phase
motor Main winding
Black U1
Red U2
White Z2
Running
capacitor
Secondary winding
Single-phase 220V
power supply Inverter
Multi-function input port
(Illustration shows the default
settings)
Forward rotation
Reverse rotation
Multi-speed
command 1
Multi-speed
command 2
Analog input port
Speed-governing
potentiometer
High-speed
Low speed
Black U
Red V
White W
(Output: 50mA)
(0~10v input)
Black U
Red V
White W
Three-phase motor
Multi-function output port
Multi-function relay R
Below 0.5A in the event of
AC250V
(Default: Failure)
RS-485 communication
(Shielded twisted pair)
Forward
rotation
Main winding
YT: Adjustablespeed motor SPC series panel type speed governor Secondary winding Velometer
Blue
Blue
White
Red
Black
Reverse
rotation
AC power
supply
Motor type CONVEYORS
Sumitomo Motor
Three-phase 200V Three-phase 400V
Lead wire type Terminal box type Lead wire type Terminal box type
<Round shaft type>
(Note) MC: Magnetic contactor. OLR: Overload relay or thermal relay.
◼ Wiring diagram of induction motor
RNYM series motors
A-102
Control panel side
Motor side
Red White
Black
Motor
Red White
Black
Motor
Control board side
Terminal box
side
Control panel side
Motor side
Control board side
Terminal box side
ITOH DENKI
◼ Electric Roller Drive
【Dimension Drawing】
Gear change (Internal External) Setting
Motor rotation direction(Clockwise Counter-clockwise)
Fault signal
Acceleration Time Speed Control Knob
Deceleration Time Speed Control Knob
Electrification
Motor type CONVEYORS
DAMON
A-103
EQUBE Low-torque drive card
EZQUBE High-torque drive card
【Size Chart】
【 Size Chart 】
【Wiring diagram】
【 Installation dimensions 】
【Installation dimensions】
◼ Electric Roller Drive
Speed Setting 32 fixed speed settings
Rotation Direction Setting ON = CCW (Counterclockwise), OFF = CW (Clockwise)
Acceleration/Decele
ration Setting 16 fixed time settings (0~2.5s)
DIP Switch Configuration Table
Speed switch Configuration
switch
Acceleration/Decel
eration Switch
Electric roller
interface DIP switch
DC24V Power I/O terminal
Motor type CONVEYORS
A-104
◼ Electric Roller Drive
CONVEYLINK-ECO Bus-type driver card
【 Size Chart 】
【 Wiring diagram 】
【 Installation dimensions 】
• Supports Profinet, Ethernet I/P, Modbus TCP, CC-LinkZPA
• (Zero Pressure Accumulation) logic;
• single-piece release, serial release and serial soft start
• Modify default configurations and customise user functions via EASYROLL
software
• Extended functions (automatic merging, automatic spacing)
• 2-zone control (connects up to 4 sensors and 2 motorised rollers)
• Automatic NPN or PNP sensor recognition
• Customisable programming
• Automatic configuration of IP addresses and operating parameters
DAMON
DIP Switch Configuration Table
Function
Speed Setting
Function
Speed switch
Configuration switch
Acceleration/Deceleration Switch
In conjunction with the speed range switch
Enables 31 fixed speed settings
Acceleration/Decele
ration Setting 16 preset acceleration/deceleration profiles
Function
Speed range
Direction of rotation setting
Error recovery method
Operating Mode
Braking Mode
Deceleration time Deceleration time=Acceleration time Deceleration time=2*Acceleration time
Three braking modes
Manual Automatic
Low gear High gear
OFF ON
Motor type CONVEYORS
Installed on the under side of the conveyor
It saves space on both sides of the conveyor.
The belt does not need to interfere with the motor, and the height of the motor position can be changed.
The standard gap between the belt surface on the return side and the upper surface of the motor is 20, 50 and 80mm.
Installed on the upper side of the conveyor
The motor is installed on the upper side of the belt, so water and oil do not directly adhere to the motor.
The height of the motor position can be changed to avoid motor interfering with the workpiece.
The standard gap between the conveying surface of the conveyor and the lower surface of the motor is 20, 50 and 80mm.
Installed on the upper outer side of the conveyor
The motor is installed on the upper side of the belt, so water and oil do not directly adhere to the motor.
Since the motor is located outside, there is no need to consider the size of the workpiece or the belt.
Direct motor connection
The motor is directly connected to the drive roller for high precision conveyance.
Since the top and bottom do not protrude, the space on the top and bottom can be effectively used.
Since the motor is mounted on the side, it is difficult for water and oil to touch it directly.
Direct connection of orthogonal hollow motor
The orthogonal hollow motor is directly connected to the pulley.
The belt and the motor are installed in parallel, so the upper and lower space can be effectively used, and the left and right
space is also saved compared with the direct motor connection.
※The 6W motor is not applicable
Installed in the middle of conveyor (middle drive type)
Even if the tension is adjusted, the overall length of the conveyor will not change, so it can be installed between non-movable
equipment.
In addition, the drive unit can also move within the effective range of the profile, so the conveyor becomes easier to service.
Installed on the inner side of the conveyor
The motor of the double-row type conveyor can be installed between profiles, so
the top, bottom, left and right space can be effectively used.
The drive chain can also be installed inside the safety cover.
Note: The content described below may not correspond to the selected conveyor model.
Thanks for your understanding.
◼ Installation method of motor
A-105
◼ Special motor types
When you want to improve the stopping accuracy
Motor with a brake
(Overdriving: 1-1.5 turns; holding force: None) The electronic brake based on current will not wear out like mechanical one, so it has a long lifespan. It is
most suitable for stepping action. Since there is no holding force, it can be used in combination with a motor with an electromagnetic brake when it is
necessary to hold a load.
Motor whose clutch has a brake (Overdriving: 1 turn; holding force: Yes) It is suitable for frequent start and stop occasions. When stopping, the clutch is disengaged and the brake is
applied. Therefore, unlike a motor with an electromagnetic brake, it is not affected by the inertia of the motor, and the time to stop can be shortened.
Motor with an electromagnetic
brake
(Overdriving: 2-3 rotations; holding force: Yes) It is suitable for the situation where the load needs to be held, such as driving the belt up or down. Since
equipped with an AC non-excitation electromagnetic brake, the motor stops instantaneously and holds the load when the power is cut off.
It is capable of handling harsh environments
Explosion-proof motor It is suitable for use in places where flammable and explosive gases may be generated.
It is a safety motor with high insulation performance against danger and damage caused by rising ambient temperature.
Dustproof and waterproof motor
It is suitable for use in environments with a lot of water flow or dust.
It has excellent dustproof and waterproof performance and complies with IEC IP66 standard. But it is not suitable for long-term immersion in water or use
under high-pressure water environment.
Motor type CONVEYORS
A:单列头部驱动基本型
Single row ,head drive,basic type
H:中间驱动,马达不同安装方向
Middle drive,different mounting
direction
V:中间驱动,马达不同安装方向
Middle drive,different mounting
direction
T中间驱动,马达不同安装方向
Middle drive,different mounting
direction
D单列/多列头部直连型驱动
ingle-row/multi-row, head directly
drive
MD多列头部驱动
Multi-rows, head drive
M单列/多列中间驱动
Single-row/multi-row, Middle drive
DM直连中间驱动型
Directly connected, intermediate
drive
DU直角向上直连型驱动
Straight Angle drive
DR直角向下直连型驱动
Straight Angle drive
MM头部中间驱动
Head center drive
CD联轴器直连型
Coupling direct connection type
HD电机在搬送面上面驱动
Motor driven on the upper side
N电机内藏型
Motor built-in type
AB单列头部驱动反装型
Single row ,head drive,backside
type
MDB多列头部驱动反装型
Multi-rows, head drive,backside
type
MDH中间驱动,马达直连,水平安装
Middle drive, head directly drive,
Horizontal mounting
MDR中间驱动,马达直连,直角向下安
装
Middle drive, head directly drive,
Straight Angle mounting
◼ Naming rules for motor installation
A-106
Note: The content described below may not correspond to the selected conveyor model.
Thanks for your understanding.
Motor type CONVEYORS
A-107
Other types of customised conveyors
Case Photos FA
CSCS81S-D
Stainless steel chain conveyor with attached plate
VCSK70-MD
Vacuum Conveyor
CSR50S-M
L-type roller line
TCBSS-100CR
Horizontal circulation Tray changer
TCBJD-CSN
Up and down circulation Tray changer
CSC140S-MD
Double Chain Heavy Duty Conveyor System
Motor type CONVEYORS
A-108
DX service
WeChat Video
• Apply for a factory tour
• Apply for paper catalogue
(China Only)
• Sample Request
• Articles & News
• 3D Drawing Download
• Catalogue Online Viewing
• Self-service downloading of
product manuals
• Self-service logistics enquiry
• Customer service online reply
Key Features
Remaining functions
Product Express
GNKE factory shooting
to explain the products
Demonstrate maintenance
methods
Maintenance Guide
CONVEYORS
North America
<Agency stores>:
1 locations
Europe
<Agency stores>:
2 locations
Corporate philosophy
Through the harmony between people and technology, we contribute to the
development of society while pursuing our better life
Global sales network
Japan
Headquarters: Kyoto
City, Kyoto Prefecture
<Subsidiary>:
3 locations
<Sales office>:
3 locations
<Technology center>:
1 location
Asia Pacific
<Agency stores>:
4 locations
<Sales office>:
3 locations
<Overseas plant>:
1 location
Website of Japanese company
http: //www.nke.co.jp
Website of Chinese company
http: //www.nke.co.jp/cn
◼ Please read the operation manual
carefully before use.
◼ Please use it within the technical
conditions and scope stipulated in the
product catalog and operation manual.
Safety Instructions
⚫ Please note that the content of this document will be altered without notice. Thanks for you
understanding!
Nakamura Kiki China Co., Ltd.
Unit 101, Building 6, No. 70 Huadu Avenue West, Tanbu
Town, Huadu District, Guangzhou City
TEL: 020-2267-5728 (Chinese and Japanese)
FAX: 020-2267-5758
GNKE Automation Technology Co.,Ltd
Unit 102, Building 6, No. 70 Huadu Avenue West, Tanbu
Town, Huadu District, Guangzhou City
GNKE Automation Technology Co.,Ltd Shanghai Branch
Room 509, Building 4, Yijing Cultural and Creative Park, 175
Chengjiaqiao Road, Minhang District, Shanghai City TEL:
021-61619630 (Business) (Japanese and Chinese) TEL: 021-
61619631 (Technical) (Japanese and Chinese)
All are
here!